You are on page 1of 1

TEST REPORT AS PER IS:13592:2013

Date: 23.06.2023
Test Report No : SIL(GA)/QA/13592/2023/851
Name of Consignee : M/s:- VELANI AND SONS-BARODA.
Size Visual Batch no. Qty. Mean Out side Diameter at Reversion Impact Water Axial Stress Tensile Resistance
Wall Thickness
(Diameter Appearance in Out Side Any Point +/- 5 Max (Failure/ Tightness Shrinkage Relief Strength at to Dichloro-
/Class) (Finish) Nos. Min. Max. Diameter Min. Max. (%) No. of of joint Test +/- 2 % Test break shall metane
Strokes Max. (only not be less at
10% for Ty-B) than 45 Mpa Specified
(mm) (mm) (mm) (mm) (mm) TIR (459 Kg/cm2) temp.
160 MM 4.00 4.60 160.0-160.5 158.00 162.00
OK ---- ----
TY -B 4.08 4.37 160.35 159.76 160.48 3.0, 3.4, 3.1 0/25 Pass 1.10% Pass 462.44 Pass

Size Qty. in Nos.


PIPE PVC- U SWR NEW TYPE- B 160 MM 3 MTRS. LG 16
Test Pressure For Water Tightness of Joint Kg/cm2 = For Ty- A and Ty- B 0.5 for 15 Minutes.
N.A.= NOT APPLICABLE

The Supreme Industries Limited - Unit No. III +.91 (0257) 3501531/41, 601 '
Gat No. 47, 47/2, 48 to 50, 55 to 66, 69, 70, 72 & 73 +.91 (0257) 3501671 6
At Post Gadegaon, Tal. Jamner info@.supreme.co.in *
Dist. Jalgaon- 425114, Maharashtra, INDIA. www.supreme.co.in 

Note : This is a system generated report, hence does not require any signature.