You are on page 1of 1

S/L

340
B D
A I4 I3 A
T1-A

1090
LC1
g - BN5
CO
36 0 L
5
s @ 3 CO 5

Sh e et LC1
17

L2

L2
5 5

CO
5

I3
LC1
5000

Ridge Flashing Ridge


LC1 Flashing Ridge Flashing
3910

CRAWL UNDER

5
CO
I4
BN5
I4

Lg -

I4

I4
5 LC1
3 36 0 5
L2

L2
ets @
Sh e CO
CO
5
17 5

LC1

T1-B
340

I4 I3
C C
1505 S/L
S/L300 B 3750 3750 D 300
7500 3150

T1-1 T1-2 T1-3

Plan View on LVL T1-8 233.000


Scale 1:75
Document Review
PLEASE NOTE:
This document has been reviewed at a high level to check overall
compliance with the engineering intent. Client to Confirm the Following:
The contractor is not relieved of any of their obligations in terms of
the contract. · Sheet Lengths
Accepted
x Accepted with comments
· Dimensions All dimensions, sheet lengths, roof slopes are to be as per BP drawings.
BP does not take responsibility for dimensional accuracy of the

Rejected / resubmit · Roof Slopes fabrication drawings


3D Viewbox-T1 & Bin
Date: 17/01/2024 Sign: · Overhangs
· Runouts Past last Purlins/Girts N.T.S
All flashing and sheeting around conveyor gantries interface at the
towers to suit the conveyor roof profile. · Flashings and their allocations

Client to Review ALL Notes on drawing DISCLAIMER NOTE :


While every care is taken to ensure both the accuracy and Co. Reg. No. 2021/511200/07

and advise where applicable. correctness of drawings and/or cutting lists, Global Roofing
Solutions will not accept responsibility or liability for costs
E: tsd@globalroofs.co.za
W: www.globalroofs.co.za

incurred as a result of drawings produced. Global Roofing


Solutions does not warrant or represent that the information
contained on this drawing is either accurate or complete.

If in Doubt Please Ask! Sole responsibility for correct design, details and dimensions
shall remain with the project Architects and Engineers.
PLEASE NOTE :
Rev. 0 Issued for approval. 2024-01-10 JMF

- All dimensions must be confirmed as correct. Global Roofing REVISION DESCRIPTION DATE BY Arch. / Eng.
Solutions is not responsible for any shortages, should details
171.5 102 35 on plan not correspond with actual site dimensions. TITLE: Contractor
This drawing is constructed 20.6 - We have allowed for overlapping, cutting and wastage in
our material list. Owner
from the following drawings - Cutting of sheets on site will be the Installer's responsibility.
37

1.5 Building
Provided by: BOSCH PROJECTS Location
69.5 Designation Approval Required Date
Project: RCL FOODS KOMATI SUGAR MILL 686 mm Cover Width CAD-DNR
BULK SUGAR STORE REBUILD
TRANSFER TOWER T1 I.B.R. 686 (With Stiffening Rib) Global Roofing Solutions (Pty) Ltd. (GRS)
Scale Drawn By

Corner of Quality Road & Barlow Road, Kempton Park, Isando 1601 Head Office Checked By Rev.
Drawing No: 10461-66-SSD-011-012 Tel.: 011 898 2900

SHEET 1 OF 3 GPS Coordinates: 26°08'44.4"S - 28°12'42.1"E Sales Rep. Drawing No.

This drawing is the property of GLOBAL ROOFING SOLUTIONS. and may not be used by or disclosed to other parties without the Executive Director's consent in writing.
360 12 23 -4 0