You are on page 1of 3

KBU6A / RS601

DC COMPONENTS CO., LTD.


THRU
R
RECTIFIER SPECIALISTS
KBU6M / RS607

TECHNICAL SPECIFICATIONS OF GLASS PASSIVATED BRIDGE RECTIFIER

VOLTAGE RANGE - 50 to 1000 Volts CURRENT - 6.0 Amperes

FEATURES
* High forward surge capability
* High capability
* High current capability
* Low forward voltage drop KBU
* Glass passivated junction
.15 x23L
3.8 x5.7L
.935(23.7)
MECHANICAL DATA .895(22.7)
HOLE THRU

* Case: Molded plastic


.300
* Epoxy: UL 94-V0 rate flame retardant .700(17.8) (7.5) .780(19.8)
* Terminals: Solder plated solderable per .600(16.8) .740(18.8)
MIL-STD-750, Method 2026 AC

* Polarity: As marked
0.79
* Mounting position: Any (20.0) .052(1.3)
* Weight: 2.24 gram MIN .048(1.2)

.220(5.6) SPACING
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS .180(4.6)
o .280(7.0)
Ratings at 25 C ambient temperature unless otherwise specified. .087(2.2) .256(6.5)
Single phase, half wave, 60Hz, resistive or inductive load. .071(1.8)
For capacitive load, derate current by 20%.
Dimensions in inches and (millimeters)

RS601 RS602 RS603 RS604 RS605 RS606 RS607


SYMBOL KBU6A KBU6B KBU6D KBU6G KBU6J KBU6K KBU6M UNITS
Maximum Recurrent Peak Reverse Voltage VRRM 50 100 200 400 600 800 1000 Volts
Maximum RMS Voltage VRMS 35 70 140 280 420 560 700 Volts

Maximum DC Blocking Voltage VDC 50 100 200 400 600 800 1000 Volts
o
Maximum Average Forward Rectified Current at TA = 100 C IO 6.0 Amps
Peak Forward Surge Current 8.3 ms single half sine-wave
IFSM 150 Amps
superimposed on rated load (JEDEC Method)

Maximum Instantaneous Forward Voltage at 3.0A DC VF 1.1 Volts


o
Maximum DC Reverse Current at Rated @TJ = 25 C 10
o IR μAmps
DC Blocking Voltage @TJ = 125 C 100
Typical Junction Capacitance (Note 1) CJ 260 pF

o
Operating and Storage Temperature Range TJ,TSTG -55 to +150 C
Note 1 :Measured at 1 MHz and applied reverse voltage of 4.0 volts.

REV-3,MAY,2017 1 www.dccomponents.com
RATING AND CHARACTERISTIC CURVES (KBU6A THRU KBU6M)

FIG. 1 FIG. 2
TYPICAL FORWARD CURRENT MAXIMUM NON-REPETITIVE FORWARD
DERATING CURVE SURGE CURRENT

PEAK FORWARD SURGE CURRENT, (A)


10 250
AVERAGE FORWARD CURRENT, (A)

8.3ms Single Half Sine-Wave


(JEDEC Method)
8 200

6 150

4 100
Single Phase
Half Wave 60Hz
2 Resistive or 50
Inductive Load
0 0
0 25 50 75 100 125 150 1 2 4 6 8 10 20 40 60 80 100
O
AMBIENT TEMPERATURE, ( C) NUMBER OF CYCLES AT 60Hz

FIG. 3 FIG. 4
TYPICAL INSTANTANEOUS TYPICAL REVERSE CHARACTERISTICS
FORWARD CHARACTERISTICS
20 1000
INSTANTANEOUS FORWARD CURRENT, (A)

10
INSTANTANEOUS REVERSE CURRENT, (μA)

3.0
100 O
TJ=125 C
1.0

O
0.3 TJ=25 C
Pulse Width=300μs
1% Duty Cycle 10
0.1 O
TJ=100 C

.03

.01 1
0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8
O
TJ=25 C
INSTANTANEOUS FORWARD VOLTAGE, (V)

.1
0 20 40 60 80 100

FIG. 5 PERCENT OF RATED PEAK REVERSE VOLTAGE, (%)


TYPICAL JUNCTION CAPACITANCE

1000
JUNCTION CAPACITANCE, (pF)

100
O
TJ=25 C

10
.1 .2 .4 1.0 2 4 10 20 40 100

REVERSE VOLTAGE, (V)

REV-3,MAY,2017 2 www.dccomponents.com
Disclaimer

Any Customer or user of this document or products described herein in such applications shall assume
all risks of such use and will agree to hold DC COMPONENTS are harmless against all damages.

DC COMPONENTS disclaims any and all liability arising out of the application or use of any product, including
consequential or incidental damages. Statement regarding the suitability of products for certain types
of applications are based on DC COMPONENTS ’s knowledge of typical requirements that are often placed
on DC COMPONENTS products in generic applications. Such statements are not binding statements about
the suitability of products for aparticular application. It is the customer's responsibility to validate that a
particular product with the properties described in the product specification is suitable for use in a particular
application.

DC COMPONENTS reserve the right to make modifications, enhancements, improvements, corrections


or other changes without further notice to this document and any product described herein, and disclaim
any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any
other disclosure relating to any product. Parameters provided in datasheets and specifications may
vary in different applications and performance may vary over time. All operating parameters, including
typical parameters, must be validated for each customer application by the customer’s technical experts.
Product specifications do not expand or otherwise modify DC COMPONENTS ’s terms and conditions
of purchase, including but not limited to the warranty expressed therein.

Unless otherwise in writing, DC COMPONENTS products are intended for use as general electronic components
in standard applications ( eg: Consumer electronic, Computer equipment, Office equipment, etc.), and not
recommended for use in a high specific application where a failure or malfunction of the device could result
in human injury or death ( eg: Aerospace equipment, Submarine cables, Combustion equipment, Safety
devices, Life support systems, etc.)

Customers using or selling DC COMPONENTS products not expressly indicated for use in such applications
do so at their own risk. If customer intended to use DC COMPONENTS standard quality grade devices for
applications not envisioned by DC COMPONENTS, please contact our sales representatives in advance.

DC COMPONENTS CO., LTD.


R

REV-3,MAY,2017 3 www.dccomponents.com

You might also like