Professional Documents
Culture Documents
Ircon Temperature Sensor
Ircon Temperature Sensor
706930 A
ECO REV. DESCRIPTION OF CHANGE PAGES DATE REVISED ECO
BY REQ.
BY
-- A Release. -- 12/5/05 SS --
NDC INFRARED ENGINEERING
12/5/05
IRCON TEMPERATURE SENSOR
This addendum describes the 8000 MicroBric setup procedure for an Ircon temperature sensor.
The Ircon temperature sensor has a measurement range of 0 – 500 °F. It provides a 1 – 5 V output
to the 8000 MicroBric. For detailed information on the Ircon temperature sensor, please refer to
the Ircon temperature sensor manual.
SETUP PROCEDURE
The Ircon temperature sensor is set up as an Analog gauge on the 8000 MicroBric.
GAGE1
SCALE. . . . . . . . . . . . 125
OFFSET. . . . . . . . . . . -125
Raw V. = 1.576
Scaled = 72
SCALE: 125
OFFSET: -125
The Raw V. and Scaled values will be displayed, and the DISPLAY button will be replaced
by a REFRESH button. Touching the REFRESH button will update the Raw V. and Scaled
values.
Raw V. is the input voltage from the Ircon temperature sensor (range: 1 – 5 V).
Scaled is the Raw V. value compensated by the SCALE and OFFSET values as follows:
SCALE = 125
OFFSET = -125
Raw V. = 1.576
= 72
5. Touch the REFRESH button to view the effect on the Scaled value.