You are on page 1of 8

REPUBLIC OF THE PHILIPPINES

TABLE OF CONTENTS DEPARTMENT OF PUBLIC WORKS & HIGHWAYS


OFFICE OF THE BUILDING OFFICIAL

OFFICE OF THE CITY ENGINEER

INSERT PERSPECTIVE HERE INSERT PERSPECTIVE HERE ARCHITECTURAL


A-01 LAND USE & ZONING
PERSPECTIVE
SITE DEVELOPMENT PLAN
VICINITY MAP
TABLE OF CONTENTS
A-02
GROUND FLOOR PLAN
SECOND FLOOR PLAN
ROOF PLAN
SCHEDULE OF DOORS
SCHEDULE OF WINDOWS
A-03
FRONT ELEVATION
LEFT SIDE ELEVATION LINE & GRADE
RIGHT SIDE ELEVATION
REAR ELEVATION
SECTION THRU "X"
SECTION THRU "Y"
REFLECTED CEILING PLAN
FLOOR TILE LAYOUT
STRUCTURAL
S-01
FOUNDATION PLAN
SECOND FLOOR FRAMING PLAN
ROOF FRAMING PLAN
ROOF TRUSS LAYOUT
S-02
STRUCTURAL DETAILS
ARCHITECTURAL
SANITARY / PLUMBING
INSERT PERSPECTIVE HERE INSERT PERSPECTIVE HERE P-01
COLD WATER LINE LAYOUT PLAN
SEWAGE / DRAINAGE LINE LAYOUT PLAN
ISOMETRIC LAYOUT PLAN
P-02
PLUMBING / SANITARY DETAILS
ELECTRICAL
E-01
LIGHTING LINE LAYOUT PLAN
POWER LINE LAYOUT PLAN
ELECTRICAL DETAILS STRUCTURAL

PERSPECTIVE
SANITARY

INSERT LOCATION MAP HERE SITE INSERT SITE DEVELOPMENT PLAN HERE ELECTRICAL

MECHANICAL

VICINITY MAP SITE DEVELOPMENT PLAN


DRAWN NOT TO SCALE DRAWN NOT TO SCALE

DESIGNER / CONTRACTOR: DESIGNER / ENGINEER-IN-CHARGE: I M P O R T A N T: PROJECT TITLE: OWNER: REVISION/S: DATE/S: CADD BY: SHEET CONTENT/S: SHEET NO. :
TABLE OF CONTENTS
PERSPECTIVE
PROPOSED 2-STOREY RESIDENTIAL SITE DEVELOPMENT PLAN
VICINITY MAP
A-01
CIVIL ENGINEER
PRC.NO.: PTR NO: PROJECT LOCATION: APPROVED BY OWNER: 01 08
VALIDITY: ISSUED ON: PROPOSED PLAN
TIN: ISSUED AT: ARCHITECTURAL PLAN
Y

12.00M 12.00M 12.00M


3.00M 9.00M 2.00M 10.00M 2.00M 10.00M
3.40M 4.10M 1.50M 4.40M 4.10M 1.50M 3.40M 6.60M
S45° 07'W, 12.00M S45° 07'W, 12.00M S45° 07'W, 12.00M

2.50M

2.50M
SERVICE AREA / KITCHEN T&B T&B

G.I. LONG-SPAN ROOFING


LAUNDRY AREA EL. +0.35M EL. +3.35M
EL. +0.40M UP DN
EL. +0.40M HALLWAY HALLWAY
EL. +0.40M

G.I. LONG-SPAN ROOFING


EL. +3.40M

5.77M

5.77M
BEDROOM 1 BEDROOM 2
BEDROOM 3 BEDROOM 4

6.80M
EL. +0.40M EL. +0.40M

G.I. LONG-SPAN ROOFING

G.I. LONG-SPAN ROOFING


EL. +3.40M EL. +3.40M
8.00M

DINING LANAI

3.27M

3.27M
S44° 53'E, 8.86M

S44° 53'E, 8.86M

S44° 53'E, 8.86M


EL. +0.40M EL. +0.90M

9.00M

9.00M
CLOSET

CLOSET
CLOSET

CLOSET

N44° 53'W, 11.27M

N44° 53'W, 11.27M

N44° 53'W, 11.27M


LANAI
11.00M

11.00M

11.00M
EL. +0.40M

11.27M

11.27M

11.27M
1HP 1HP 1HP 1HP
ACU ACU ACU ACU
2.75M 2.90M 2.75M 2.90M
LIVING
EL. +0.40M
GENKAN

2HP CONDENSER
EL. +0.30M
2HP SPLIT ACU

2-CARS GARAGE
EL. +0.30M

5.50M

5.50M
G.I. LONG-SPAN ROOFING G.I. LONG-SPAN ROOFING

4.47M
UP UP
FRONT YARD
LANDSCAPE
3.00M

X X
GARDENING
S8

S8

S8


2.00M

2.00M
EL. +0.30M FRONT YARD FRONT YARD
03

03

03
'E

'E

'E
EL. +0.30M EL. +0.30M
,2

,2

,2
.9

.9

.9
9M

9M

9M
N46° 44'E, 9.91M N46° 44'E, 9.91M N46° 44'E, 9.91M

2.00M 1.50M
2.98M 3.50M 5.50M 1.98M 4.50M 5.50M 1.98M 4.50M 5.50M
11.99M 11.99M 11.99M

GROUND FLOOR PLAN SECOND FLOOR PLAN ROOF PLAN


SCALE: 1:100M SCALE: 1:100M SCALE: 1:100M

0.90 2.00 0.80 0.70 1.20 1.20


0.40

0.90

1.20
2.10

2.10

2.10
1.75

0.95

0.65
0.10

FINISH FLOOR LEVEL FINISH FLOOR LEVEL

MAIN DOOR SLIDING GLASS DOOR BEDROOM DOOR T&B DOOR KITCHEN WINDOW BEDROOM & HALLWAY WINDOW
PRE-FABRICATED SLIDING GLASS DOOR PRE-FABRICATED PVC SWING DOOR SLIDING GLASS WINDOW SLIDING GLASS WINDOW
WOODEN SWING DOOR WITH DARK GRAY ALUMINUM WOODEN SWING DOOR WITH FIXED LOUVER WITH DARK GRAY ALUMINUM WITH DARK GRAY ALUMINUM
DARK GRAY COLOR JAMB AND FRAME DARK GRAY COLOR JAMB AND FRAME JAMB AND FRAME
WITH POWDERCOATED POWDERCOATED POWDERCOATED
TOP GLASS HEADER WITH WITH WITH
2-PANELS OF 5mm THICK CLEAR GLASS 2-PANELS OF 5mm THICK CLEAR GLASS 2-PANELS OF 5mm THICK CLEAR GLASS
AND 1-SCREEN PANEL AND 1-SCREEN PANEL AND 1-SCREEN PANEL

SCHEDULE OF DOORS WINDOW SCHEDULE


SCALE: 1:50M SCALE: 1:50M

DESIGNER / CONTRACTOR: DESIGNER / ENGINEER-IN-CHARGE: I M P O R T A N T: PROJECT TITLE: OWNER: REVISION/S: DATE/S: CADD BY: SHEET CONTENT/S: SHEET NO. :
GROUND FLOOR PLAN
SECOND FLOOR PLAN
ROOF PLAN
SCHEDULE OF DOORS AND WINDOWS
A-02
PROJECT LOCATION: APPROVED BY OWNER: 02 08
PROPOSED PLAN
ARCHITECTURAL PLAN
12.00M
2.00M 10.00M
LANAI ROOFING 3.40M 6.60M
SAME AS GARAGE ROOFING
S45° 07'W, 12.00M

WOOD SLAT CLADDING


SEE DETAILS
METAL FURRING SYSTEM
SEE CEILING DETAILS
GARAGE ROOFING
G.I. LONG SPAN ROOFING
TOP OF ROOF SEE DETAILS TOP OF ROOF
EL.+6.58 EL.+7.78

0.78

0.78

6.80M
LINE OF CEILING LINE OF CEILING
EL.+6.40 EL.+7.00
LANAI

S44° 53'E, 8.86M


EL. +0.90M FICEM BOARD

9.00M
WINDOW-TYPE ACU 4MM THICK

N44° 53'W, 11.27M


OPENING
3.00

3.00
(1 PER BEDROOM)

11.00M

11.27M
GLASS WINDOW
SECOND FLOOR LEVEL ON WOOD FRAMING SECOND FLOOR LEVEL
EL.+4.00 EL.+4.00
SEE DETAILS
FIRE WALL
3.00

3.00
PLAIN CEMENT FINISH
PAINTED

4.47M
MAIN DOOR
GROUND FLOOR LEVEL DARK GRAY COLOR GROUND FLOOR LEVEL

S8
EL.+1.00 SAME AS GUTTER COLOR EL.+1.00


2.00M
FRONT YARD

03
1.00

1.00

'E
,
EL. +0.30M

2.
ROAD LEVEL ROAD LEVEL

99
M
EL.+0.00 SLIDING GLASS DOOR EL.+0.00

SECTION THRU "X" ON ALUMINUM FRAME


SEE SCHEDULE OF DOORS SECTION THRU "Y" N46° 44'E, 9.91M

SCALE: 1:100M SCALE: 1:100M


1.98M 4.50M 5.50M
11.99M
WOOD SLAT CLADDING
SEE DETAILS
REFLECTED CEILING PLAN METAL FURRING SPACED
@ 0.60m O.C.
G.I. LONG SPAN ROOFING
SEE DETAILS SCALE: 1:100M
TOP OF ROOF TOP OF ROOF
EL.+6.58 EL.+7.78 MAIN CHANNEL SPACED
0.78

0.78
HANGER @ 1.20m O.C.
LINE OF CEILING LINE OF CEILING
EL.+6.40 FIRE WALL EL.+7.00
WALL ANGLE
3.00

3.00
WINDOW-TYPE ACU FICEM BOARD
OPENING 4mm THICK
1.20
SECOND FLOOR LEVEL PLAIN CEMENT FINISH SECOND FLOOR LEVEL
EL.+4.00 PAINTED EL.+4.00 1.20
TUBULAR STEEL 0.60
GRILLES 1.00M HEIGHT 0.60 X 0.60 0.60
PAINTED FINISH
3.00

3.00
CERAMIC TILES

TUBULAR STEEL
AS PER OWNERS'
SPECIFICATION CEILING DETAILS (ISOMETRIC)
GARAGE GATE TYPICAL TO
GROUND FLOOR LEVEL GROUND FLOOR LEVEL KITCHEN, LIVING,
SCALE: NTS
PAINTED FINISH
EL.+1.00 EL.+1.00 DINING & HALLWAY
1.00

1.00
ROAD LEVEL ROAD LEVEL 12.00M
EL.+0.00 EL.+0.00 3.00M 9.00M
3.40M 4.10M 1.50M
CHB EXTERIORR WALL S45° 07'W, 12.00M
SMOOTH FINISH (PAINTED)

FRONT ELEVATION 1.00M HEIGHT


LEFT SIDE ELEVATION SAME AS T&B
0.30 X 0.30
CERAMIC TILES

2.50M
TILES AS PER OWNERS'
SCALE: 1:100M SCALE: 1:100M
UP SPECIFICATION
TYPICAL TO ALL
T&B (FLOOR TO WALL)
12.00 11.27 0.40 X 0.40

5.77M
CERAMIC TILES
5.55 0.75 2.90 2.80 FIRE WALL 4.30 1.40 5.57 AS PER OWNERS'
SPECIFICATION

8.00M

3.27M
0.60 X 0.60

S44° 53'E, 8.86M


CERAMIC TILES

0.10
TOP OF ROOF TOP OF ROOF AS PER OWNERS'
1.00

1.00

N44° 53'W, 11.27M


EL.+6.58 EL.+7.78 SPECIFICATION
0.78

0.78

11.00M
TYPICAL TO ALL

11.27M
LINE OF CEILING LINE OF CEILING
EL.+6.40 EL.+7.00 BEDROOM
3.00

3.00
3.00

3.00
0.20

5.50M
0.30

0.30

SECOND FLOOR LEVEL SECOND FLOOR LEVEL


0.40

EL.+4.00 EL.+4.00

3.00M

S8
GARAGE FLOORING


03
3.00

3.00
SLAB ON FILL

'E
,2
3.40

.9
SMOOTH FINISH
3.00

9M
FIRE WALL N46° 44'E, 9.91M
GROUND FLOOR LEVEL GROUND FLOOR LEVEL
EL.+1.00 EL.+1.00 2.00M 1.50M
1.00

1.00
ROAD LEVEL ROAD LEVEL 2.98M 3.50M 5.50M
EL.+0.00 EL.+0.00 11.99M

REAR ELEVATION RIGHT SIDE ELEVATION FLOOR TILE LAYOUT


SCALE: 1:100M SCALE: 1:100M SCALE: 1:100M

DESIGNER / CONTRACTOR: DESIGNER / ENGINEER-IN-CHARGE: I M P O R T A N T: PROJECT TITLE: OWNER: REVISION/S: DATE/S: CADD BY: SHEET CONTENT/S: SHEET NO. :
FRONT ELEVATION
LEFT ELEVATION
RIGHT ELEVATION
REAR ELEVATION
A-03
SECTION THRU "X"
PROJECT LOCATION: APPROVED BY OWNER: SECTION THRU "Y"
REFLECTED CEILING PLAN
03 08
FLOOR TILE LAYOUT PROPOSED PLAN
ARCHITECTURAL PLAN
A B C D E A B C D E C D E

12.00M 12.00M
2.92M 3.40M 2.60M 3.08M 2.92M 3.40M 2.60M 3.08M 2.60M 3.08M

WF-1 WF-1 S45° 07'W, 12.00M FTB FTB RB-1 RB-1 S45° 07'W, 12.00M B-1 B-1 S45° 07'W, 12.00M RB-1 RB-1
1 1 1
C2/F2 C2/F2
C1/F1 C1/F1 C1/F1

2.67M

2.67M

2.67M
RB-1

RB-1

RB-1
FTB

FTB

FTB

B-1

B-1

B-1
FTB FTB B-1 B-1
2 2 2
5.92M

5.92M

RB-2

RB-2
WF-1

WF-1
C1/F1 C1/F1 C1/F1
S44° 53'E, 8.86M

S44° 53'E, 8.86M

S44° 53'E, 8.86M


3.27M

3.27M

3.27M
RB-1

RB-1

RB-1
FTB

FTB

FTB

B-1

B-1

B-1
N44° 53'W, 11.27M

N44° 53'W, 11.27M

N44° 53'W, 11.27M


11.00M

11.00M

11.00M

11.00M
FTB FTB RB-1 RB-1 B-1 B-1 RB-1 RB-1
3 3 3
C2/F2 C2/F2
C1/F1 C1/F1 C1/F1
WF-1
1.93M

1.93M
1.91M

1.91M
RB-1

RB-1

RB-1
WF-1

RB-1 RB-2
4 4
C2/F2 WF-1 C2/F2 C2/F2

WF-1
3.15M

3.15M

3.15M

3.15M
RB-1

RB-1
S8

S8

S8


03

03
03

'E

'E
'E

,2

,2
,2.

.9

.9
9

RB-2

9M

9M
9M

WF-1

C2/F2
N46° 44'E, 9.91M
C2/F2
5 N46° 44'E, 9.91M
5 N46° 44'E, 9.91M

2.92M 3.35M 5.73M 2.92M 3.35M 5.73M

12.00M 12.00M

FOUNDATION PLAN SECOND FLOOR FRAMING PLAN ROOF FRAMING PLAN


SCALE: 1:100M SCALE: 1:100M SCALE: 1:100M

A B C D E C D E

12.00M
2.92M 3.40M 2.60M 3.08M 2.60M 3.08M
TR-1 TR-1
SEE DETAILS SEE DETAIL
S45° 07'W, 12.00M S45° 07'W, 12.00M
1 1

2.67M

2.67M
C-PURLINS
2" x 3"

2 2
5.92M

C-PURLINS
S44° 53'E, 8.86M

S44° 53'E, 8.86M


3.27M

3.27M
2'' x 3''

N44° 53'W, 11.27M

N44° 53'W, 11.27M


11.00M

11.00M
3 3
1.93M

1.91M
10mmØ SAG RODS
10mmØ SAGRODS
4
3.15M

3.15M
TR-1
S8

S8
SEE DETAILS


03

03
'E

'E
,2

,2
10mmØ SAG RODS
.9

.9
9M

9M
N46° 44'E, 9.91M
5 N46° 44'E, 9.91M

C-PURLINS
2'' x 3''
2.92M 3.35M 5.73M

12.00M

SECOND FLOOR TRUSS LAYOUT ROOF TRUSS LAYOUT


SCALE: 1:100M SCALE: 1:100M

DESIGNER / CONTRACTOR: DESIGNER / ENGINEER-IN-CHARGE: I M P O R T A N T: PROJECT TITLE: OWNER: REVISION/S: DATE/S: CADD BY: SHEET CONTENT/S: SHEET NO. :
FOUNDATION PLAN
SECOND FLOOR FRAMING PLAN
PROPOSED 2-STOREY RESIDENTIAL ROOF FRAMING PLAN
ROOF TRUSS LAYOUT
S-01
CIVIL ENGINEER
PRC.NO.: PTR NO: PROJECT LOCATION: APPROVED BY OWNER: 04 08
VALIDITY: ISSUED ON: PROPOSED PLAN
TIN: ISSUED AT: STRUCTURAL PLAN
1.20 NATURAL GRADE LINE

8-16mmØ BASEBARS EQUALLY 100mm THK CHB

0.30
SPACED BOTHWAYS INTERIOR WALL
STRUCTURAL SPECIFICATIONS
NATURAL GRADE LINE
A.) CONCRETE

(1.40m MINIMUM)
10mm Ø HOR. BARS @ EVERY
3 LAYERS ON CENTER A.1) COLUMNS ------------- ------------ f'c = 21 Mpa (3000 psi) @ 28TH DAY

VARIES
A.2) FOOTINGS, REINFORCED CONCRETE --------- f'c = 21 Mpa (3000 psi) @ 28TH DAY
WALLS, STAIRS & FOOTING TIE BEAMS

0.75
10mmØ VERT. BARS @ EVERY A.3) SUSPENDED SLABS, BEAMS & GIRDERS ------ f'c = 21 Mpa (3000 psi) @ 28TH DAY

1.00m
400mm ON CENTER
6-16mmØ CONT. BARS W/ A.4) GROUND FLOOR SLAB ON FILL ------------ f'c = 17 Mpa (2500 psi) @ 28TH DAY
1.20

0.35

10mmØ TIES SP. 2@0.05, 3@0.10


3@0.15, REST @ 0.20 M.O.C A.5) OTHERS NOT SPECIFIED ---------------- f'c = 21 Mpa (3000 psi) @ 28TH DAY
3-12mmØ HORIZONTAL BARS

0.25
CONT. B.) REINFORCEMENT
B.1) ALL MILD REINFORCING BARS SHALL BE ROUND DEFORMED "INTERMEDIATE GRADE" CONFORMING

0.25
TO ASTM A-615 -------------------- fy = 276 Mpa (40,000 psi)
0.10m THICK GRAVEL BED
B.2) ALL REINFORCING BAR DIAMETER IN MILLIMETER INDICATED ON THE PLANS SHOULD BE
10mm THK. COMPACTED STRICTLY FOLLOWED ANY DEVIATION FROM THOSE SPECIFIED SHALL HAVE WRITTEN
GRAVEL BASE APPROVAL OF THE STRUCTURAL ENGINEER
0.25
PLAN ELEVATION B.3) WHERE SPLICING IS REQUIRED, SLAB, BEAM & GIRDER REINFORCING BARS SHALL BE
SPLICED AT QUARTER POINT AND A MINIMUM LENGTH OF 40 TIMES THE DIAMETER OF
C2 - F2 WALL FOOTING DETAILS (WF-1) THE BAR

SCALE: NTS B.4) COLUMN VERTICAL BARS SHALL BE SPLICED AT MID-FLOOR HEIGHT, AND A MINIMUM
1.50 LENGTH OF 40D ALSO, NOT MORE THAN 50% OF THE TOTAL NUMBER OF BARS SHALL
BE SPLICED AT ANY GIVEN SECTION

0.35 NATURAL GRADE LINE B.5) ALL REINFORCING BARS ARE WELDABLE

C.) STRUCTURAL STEEL


0.20

0.40
C.1) ALL STRUCTURAL STEEL, BOTH ANGLES AND STEEL PLATES SHALL CONFORM TO
C-PURLINS ANGLE BAR ASTM A36 ------------------------- fy = 248 Mpa (36,000 psi)
2'' X 3'' TRUSSES
10mmØ 50mm x 5mm thk
SPACED @ SAG RODS C.2) WELDING ELECTRODES SHALL BE 70XX SERIES

0.30
(1.40m MINIMUM) 800mm O.C.
G.I. LONG SPAN C.3) MACHINE BOLTS AND ANCHOR BOLTS SHALL CONFORM TO ASTM A-325
VARIES

8-16mmØ BASEBARS PRE-PAINTED


EQUALLY ROOFING D.) STANDARD CONSTRUCTION PROCEDURES AS PER "NATIONAL BUILDING CODE" AND
6-16Ø CONT. BARS W/ 10mmØ "NATIONAL STRUCTURAL CODE FOR BUILDINGS" SHOULD BE STRICTLY FOLLOWED IN THE
TIES SPACED 2@0.05, 3@0.15, EXECUTION OF THE PROJECT
1.50

0.35

8-16mmØ CONT. BARS W/ REST @ 0.20 M.O.C.

VARIES
10mmØ TIES SP. 2@0.50, E.) IT SHALL BE THE DUTY AND RESPONSIBILITY OF THE CONSTRUCTOR TO PROVIDE SHEET
3@0.10, 3@0.15
FOOTING TIE BEAM DETAIL PILES, PRECAUTIONARY MEASURES TO ENSURE SAFETY OF ADJACENT PROPERTIES AND

0.20
REST @ 0.20 M.O.C. OCCUPANTS
SCALE: NTS

0.90 0.90 0.90 0.90 0.90 0.90 0.90


0.30

12mmØ REINF. BARS


SPACED @ 150mm O.C.
0.10m THICK GRAVEL BED DETAILS OF RAFTER (TR-1) 10mmØ STRAIGHT TOP
PLAN SCALE: NTS
AND BOTTON BARS @ 300mm
B.W.

C1 - F1 ELEVATION 3.27m

1.09m
COLUMN FOOTING DETAIL 10mmØ NOSING BAR

SCALE: NTS

1.03m
L L

L/4 L/2 L/4 L/4 L/2 L/4 STAIR PLAN


S M S S 16mmØ CONT. BAR M 16mmØ CUT BAR
S
16mmØ CONT. BAR 16mmØ CUT BAR
12mmØ SHEAR BAR
L/3 SPACED @ 150mm O.C.

3.08m

1.02m
0.125
BENT BARS @ L/3
FROM SUPPORT

10mmØ NOSING BAR 10mmØ CONT. BARS


16mmØ CONT. BAR 16mmØ CONT. BAR SPACED @ 125mm O.C
10mmØ STIRRUPS SP. 3@0.05, 10mmØ STIRRUPS SP. 3@0.05,
3@0.10, 3@0.15, REST @ 0.20m O.C. 16mmØ BENT UP BAR 3@0.10, 3@0.15, REST @ 0.20m O.C. 16mmØ BENT UP BAR
L/3 12mmØ REINF. BARS

1.03m
L/5 L/5 L/5 L/5
SPACED @ 150mm O.C.

0.1
25
ROOF BEAM DETAIL RC BEAM DETAILS 10mmØ CONT. BARS
SPACED @ 125mm O.C.

0.125
SCALE: NTS SCALE: NTS
3.27m
0.25 0.25 0.20 0.20 0.25 0.25 0.10
0.30
STAIR SECTION 1.09 1.09 1.09

6-16mmØ 4-16mmØ 4-16mmØ 2-16mmØ 5-16mmØ 3-16mmØ 1-10mmØ 10mmØ NOSING BAR 10mmØ BENT UP 10mm Ø TOP AND BOTTOM BARS 150mm THICK

0.20
SPACED @ 300mm B.W.
BARS @ L/3 SLAB
10mmØ C-TIES
0.35

0.35

0.30

0.30

0.35

0.35

0.15

2-12mmØ 2-12mmØ SPACED @ EVERY


10mmØ CHAIR BAR
0.20m O.C.
NOTE: PROVIDE LINTEL BEAM ON ALL DOOR AND
4-16mmØ 6-16mmØ 2-16mmØ 4-16mmØ 3-16mmØ 5-16mmØ 1-10mmØ WINDOW HEADERS AROUND PERIMETER WALLS 10mmØ TOP AND BOTTOM
@ SUPPORT @ MID SPAN @ SUPPORT @ MID SPAN @ SUPPORT @ MID SPAN TYP. DETAILS OF RC STAIR BARS SPACED @ 0.30mm B.W.

B-1 RB-1 RB-2 LINTEL BEAM SCALE: NTS


DETAILS OF SLAB
SCHEDULE OF BEAMS SCALE: NTS
SCALE: NTS

DESIGNER / CONTRACTOR: DESIGNER / ENGINEER-IN-CHARGE: I M P O R T A N T: PROJECT TITLE: OWNER: REVISION/S: DATE/S: CADD BY: SHEET CONTENT/S: SHEET NO. :
STRUCTURAL DETAILS

PROPOSED 2-STOREY RESIDENTIAL S-02


CIVIL ENGINEER
PRC.NO.: PTR NO: PROJECT LOCATION: APPROVED BY OWNER: 05 08
VALIDITY: ISSUED ON: PROPOSED PLAN
TIN: ISSUED AT: STRUCTURAL PLAN
SEW 100
ER P mm
IPE
FD C 10
S45° 07'W, 12.00M S45° 07'W, 12.00M
WO
C LAV DOW0mm S
N PI EWER
TO MAIN STREET

FD FD
DRAINAGE

LAV CB KSK
WC WC PE
UP CO DN CO
LAV LAV
100mmØ SEWER
DOWN PIPE
100mmØ SEWER
DOWN PIPE DS DS
FD C
WO

SEWER PIPE
100

100mmØ
C LAV mm
S44° 53'E, 8.86M

S44° 53'E, 8.86M


SEW

N44° 53'W, 11.27M

N44° 53'W, 11.27M


ER P
R IPE
S EWPEIPE DS

SEWER PIPE
m
DS 100mDOWN

100mmØ
KSK
TO MAIN STREET
DRAINAGE

CB
TIC
SEP TANK
SEPTIC VAULT SEPTIC VAULT
CB
UP UP

CB
S8

S8
LAV


03

03
OUTLET
'E

'E
,2

,2
CB
.9

.9
CB
9M

9M
N46° 44'E, 9.91M N46° 44'E, 9.91M
TO M
DRAAIN ST ET
INA REET CB TREAGE
GE N S N
TO MAIN STREET TO MAIN STREET
AI RAI
TO M D
DRAINAGE DRAINAGE
CB
GROUND FLOOR SECOND FLOOR
SEWAGE / DRAINAGE LINE LAYOUT PLAN SEWAGE / DRAINAGE LINE LAYOUT PLAN ET
SCALE: 1:100M SCALE: 1:100M
TO M
N S TREAGE
DRAAIN ST AI RAI N
INA REET TO M D
GE
ISOMETRIC LAYOUT
20mmØ CWL 20mmØ CWM
RISER PIPE RISER PIPE SEWAGE / DRAINAGE LINE LAYOUT PLAN
20mmØ CWL PIPE S45° 07'W, 12.00M
20mmØ CWL PIPE S45° 07'W, 12.00M SCALE: 1:100M

SHO SHO
HB KSK
WC WC
UP DN
LAV LAV
20mmØ CWL PIPE

SHO
S44° 53'E, 8.86M

S44° 53'E, 8.86M


N44° 53'W, 11.27M

N44° 53'W, 11.27M


m CWPILPE WC LAV
HB
20mRISER
SHO

UP UP
WL
GV
0 m m RC PIPE WC LAV
S8

S8

2 RISE

M
03

03

PIPE
'E

'E

PIPE m
,2

,2
.9

.9

CV
9M

9M

W L L
mC
N46° 44'E, 9.91M N46° 44'E, 9.91M
W
C 20m
WATER
SOURCE 20m HB
KSK
M
GROUND FLOOR SECOND FLOOR HB ISOMETRIC LAYOUT CV
ER
COLD WATER LINE LAYOUT COLD WATER LINE LAYOUT COLD WATER LINE LAYOUT WSAOTURCE
SCALE: 1:100M SCALE: 1:100M SCALE: 1:75M

DESIGNER / CONTRACTOR: DESIGNER / ENGINEER-IN-CHARGE: I M P O R T A N T: PROJECT TITLE: OWNER: REVISION/S: DATE/S: CADD BY: SHEET CONTENT/S: SHEET NO. :
COLD WATER LINE LAYOUT PLAN
SEWAGE / DRAINAGE LINE LAYOUT PLAN
PROPOSED 2-STOREY RESIDENTIAL ISOMETRIC LAYOUT PLAN P-01
CIVIL ENGINEER
PRC.NO.: PTR NO: PROJECT LOCATION: APPROVED BY OWNER: 06 08
VALIDITY: ISSUED ON: PROPOSED PLAN
TIN: ISSUED AT: SANITARY/PLUMBING
10mmØ TEMP.BARS SPACED 10mmØ TEMP. BARS SPACED
@ 0.20m O.C. BOTHWAYS @ 0.20m O.C. BOTHWAYS
MANHOLE MANHOLE MANHOLE

0.20

0.20
4"Ø PVC TEE 4"Ø PVC TEE
4"Ø PVC INLET 4"Ø PVC INLET
PIPE WATER LEVEL WATER LEVEL PIPE

WATER LEVEL 4" thk CHM w/


4" thk CHB w/ 10mmØ 10mmØ VERT. BARS
VERT. BARS SPACED @
1.80

1.80
SPACED @ 0.60m O.C.
2.00 m

0.60m O.C. AND HOR. BARS


2.00m

2.00m
AND HOR. BARS
PLACED @ EVERY 3 LAYERS

1.70

1.70
PLACED @ EVERY 3
OF CHB

1.60

1.60
LAYERS OF CHB

10mmØ MATT.
10mmØ MATT BARS BARS SPACED
SPACED @ 0.20m O.C. @ 0.20m O.C.
BOTHWAYS BOTHWAYS
5% SLOPE 5% SLOPE 5% SLOPE
0.20

0.20
3-10mmØ CONT. BARS 3-10mmØ CONT. BARS
W/ 8mmØ TIES SPACED
w/ 8mmØ TIES SPACED
@ 0.30m O.C. 0.30 SECTION 0.30 0.30 SECTION 0.30 @ 0.30m O.C.

SEPTIC TANK DETAILS


LEGEND SCALE: NTS

SYMBOL DESCRIPTION SEWER LINE PIPE SIZE


4"Ø PVC OUTLET PIPE
FAU FAUCET

KS KITCHEN SINK Ø 50 MM 8.00m


0.10 3.00m 0.10 1.60 0.10 3.00m 0.10
WC WATER CLOSET Ø 100 MM
10mmØ TEMP. BARS 10mmØ TEMP. BARS
PLACED @ 0.20m O.C. PLACED @ 0.20m O.C.
CV CHECK VALVE BOTHWAYS BOTHWAYS
0.10

0.10

0.10

0.10
GV GATE VALVE

FD FLOOR DRAIN Ø 50 MM

LAV LAVATORY Ø 50 MM
1.70m
1.50m

1.70m
1.50
HB HOSE BIBB. CWL
MANHOLE MANHOLE MANHOLE
CO CLEAN OUT DIGESTIVE CHAMBER DIGESTIVE CHAMBER
LEECHING
M WATER METER
CHAMBER
0.10

0.10

0.10

0.10
CB CATCH BASIN

DS DOWN SPOUT Ø 100 MM


4"Ø PVC 4"Ø PVC
INLET PIPE INLET PIPE

SEPTIC TANK TOP VIEW


SCALE: NTS
4"Ø S-1000PVC INLET
PIPE WITH COVER

0.10m THK CONCRETE


SLAB w/ 10mmØ REBARS
@ 0.20m O.C. BOTHWAYS
0.60m
SPECIFICATIONS

ALL PLUMBING WORKS INCLUDED HEREIN SHALL BE EXECUTED ACCORDING TO THE PROVISIONS OF THE NATIONAL PLUMBING CODE, THE NATIONAL BUILDING
CODE AND RULES AND REGULATIONS OF SANTA ROSA CITY LAGUNA & AUTHORITIES HAVING JURISDICTION

COORDINATE THE DRAWING WITH OTHER RELATED DRAWINGS AND SPECIFICATIONS, THE ARCHITECT / ENGINEER SHALL BE NOTIFIED IMMEDIATELY OF ANY
0.60m

DISCREPANCY FOUND THEREIN


MANHOLE
ALL PIPES SHALL BE INSTALLED AS INDICATED ON PLANS. ANY RELOCATIONS REQUIRED FOR PROPER EXECUTION OF OTHER TRADE SHALL BE WITH PRIOR
APPROVAL OF THE ARCHITECT

4" x 8" x 16" CHB PROPOSED SANITARY UTILITIES SHALL CONFORM TO THE ACTUAL LOCATION, DEPTH AND INVERT ELEVATION OF ALL EXISTING PIPES AND STRUCTURES AS
VERIFIED BY THE CONTRACTOR

ALL SLOPE OF HOUSE AND SEWER DRAIN SHALL BE 2% TO THE DIRECTION OF THE WATER

THE CONTRACTOR SHALL VERIFY ALL EXISTING UTILITIES AT SITE, COORDINATE THE WORKS WITH THE SEWER LINE EFFICIENT DISPOSAL POINT AND WATER
MANHOLE COVER DETAILS LINE SERVICE CONNECTING POINT.

ALL OTHER REQUIREMENTS SHOULD BE FOLLOWED. THE REVISION OF THE NATIONAL PLUMBING CODE OF THE PHILIPPINES & RA 1378 PREVAIL.
SCALE: NTS

DESIGNER / CONTRACTOR: DESIGNER / ENGINEER-IN-CHARGE: I M P O R T A N T: PROJECT TITLE: OWNER: REVISION/S: DATE/S: CADD BY: SHEET CONTENT/S: SHEET NO. :
PLUMBING / SANITARY DETAILS

PROPOSED 2-STOREY RESIDENTIAL P-02


CIVIL ENGINEER
PRC.NO.: PTR NO: PROJECT LOCATION: APPROVED BY OWNER: 07 08
VALIDITY: ISSUED ON: PROPOSED PLAN
TIN: ISSUED AT: SANITARY/PLUMBING
LOAD SCHEDULE
C1 C2 C3
C4
TO PANEL BOARD S45° 07'W, 12.00M CIRCUIT VOLT AMPERE CIRCUIT BREAKER
S45° 07'W, 12.00M LOAD DESCRIPTION QUANTITY (VA) VOLTAGE AMPERES CIRCUIT RUN WIRE SIZE CONDUIT SIZE
NUMBER AT AF Ø-VOLTAGE
PB
1 LIGHTING 6 - LIGHTING OUTLET 600 230 2.61 2 - 2.0 sq.mm THHN wire 20mmØ PVC 20 AT 50 AF 2P, 230v
EF EF
VTR VTR
UP Sa Sa Sa
DN 2 LIGHTING 6 - LIGHTING OUTLET 600 230 2.61 2 - 2.0 sq.mm THHN wire 20mmØ PVC 20 AT 50 AF 2P, 230v
S ab
3 LIGHTING 5 - LIGHTING OUTLET 500 230 2.17 2 - 2.0 sq.mm THHN wire 20mmØ PVC 20 AT 50 AF 2P, 230v
S ab Sa Sa Sa Sa
4 LIGHTING 4 - LIGHTING OUTLET 400 230 1.74 2 - 2.0 sq.mm THHN wire 20mmØ PVC 20 AT 50 AF 2P, 230v
S44° 53'E, 8.86M

S44° 53'E, 8.86M


CONVENIENCE 10 - 2 GANG CONVENIENCE OUTLET 2 - 3.5 sq.mm THHN wire
5 1800 230 7.83 1 - 2.0 sq.mm THHN wire (G) 20mmØ PVC 30 AT 50 AF 2P, 230v
OUTLET WITH GROUND

N44° 53'W, 11.27M

N44° 53'W, 11.27M


S ab 2 - 8.0 sq.mm THHN wire
6 LAUNDRY OUTLET 1 - LAUNDRY OUTLET 1840 230 8.0 1 - 3.5 sq.mm THHN wire (G) 20mmØ PVC 30 AT 50 AF 2P, 230v

2 - 8.0 sq.mm THHN wire


7 AIRCON LOAD 1 - AIRCON 2 HP 2760 230 12.0 1 - 3.5 sq.mm THHN wire (G) 20mmØ PVC 40 AT 50 AF 2P, 230v

2 - 8.0 sq.mm THHN wire


S abc 8 AIRCON LOAD 1 - AIRCON 1 HP 1840 230 8.0 1 - 3.5 sq.mm THHN wire (G) 20mmØ PVC 30 AT 50 AF 2P, 230v

2 - 8.0 sq.mm THHN wire


9 AIRCON LOAD 1 - AIRCON 1 HP 1840 230 8.0 1 - 3.5 sq.mm THHN wire (G) 20mmØ PVC 30 AT 50 AF 2P, 230v
UP UP

2 - 8.0 sq.mm THHN wire


10 AIRCON LOAD 1 - AIRCON 1 HP 1840 230 8.0 20mmØ PVC 30 AT 50 AF 2P, 230v
1 - 3.5 sq.mm THHN wire (G)
S8

S8


03

03
'E

'E
,2

,2
2 - 8.0 sq.mm THHN wire
.9

.9
11 AIRCON LOAD 1 - AIRCON 1 HP 1840 230 8.0 20mmØ PVC 30 AT 50 AF 2P, 230v
9M

9M
1 - 3.5 sq.mm THHN wire (G)
N46° 44'E, 9.91M N46° 44'E, 9.91M 2 - 8.0 sq.mm THHN wire
12 RANGE 1 - RANGE 1840 230 8.0 20mmØ PVC 30 AT 50 AF 2P, 230v
1 - 3.5 sq.mm THHN wire (G)
2 - 8.0 sq.mm THHN wire
13 RERIGERATOR 1 - REFRIGERATOR 1840 230 8.0 20mmØ PVC 30 AT 50 AF 2P, 230v
1 - 3.5 sq.mm THHN wire (G)

14 SPARE

TOTAL 19540 84.96

GROUND LIGHTING LAYOUT SECOND FLOOR LIGHTING LAYOUT


SCALE: 1:100M SCALE: 1:100M
DESIGN COMPUTATION & ANALYSIS GENERAL NOTES
APPLICATION OF DEMAND FACTOR: 1. ALL ELECTRICAL WORKS, HEREIN SHALL BE DONE IN ACCORDANCE WITH THE
(84.96 - 12) x 80% = 58.37 + 100% (40) = 98.37 Amperes REQUIREMENTS OF THE NATIONAL BUILDING CODE, THE PHILIPPINE ELECTRICAL CODE,
THE RULES AND REGULATION OF THE LOCAL GOVERNMENT, AND THE REQUIREMENT
FOR MAIN FEEDER CONDUCTOR: OF THE LOCAL ELECTRIC UTILITY.
2. ALL MATERIALS TO BE USED SHALL BE NEW AND OF GOOD QUALITY.
C11
C6 C12 C13 USE : 2 - 38 sq.mm THHN CONDUCTOR + 3. LIGHTING BRANCH CIRCUIT SHALL BE 3.5 sq.mm THHN STRANDED WIRE IN 20mmØ PVC
S45° 07'W, 12.00M S45° 07'W, 12.00M 1 - 14 sq.mm THHN CODUCTOR (ground) in 35mmØ RMC PIPE.
4. CONVENIENCE OUTLET CIRCUIT SHALL BE 5.5 sq.mm THHN STRANDED WIRE IN 20mmØ
LAUNDRY PB RANGE REF
PVC PIPE.
FOR MAIN OVER-CURRENT PROTECTION DEVICE: 5. AIRCON OUTLET CIRCUIT SHALL BE 8.0 sq.mm THHN STRANDED WIRE IN 20mmØ PVC
C5
C5 PIPE
USE : 125 AT, 60 Hz, 1Ø, 230V, 2P, BOLT-ON TYPE CIRCUIT BREAKER 6. MOUNTING HEIGHT OF DEVICE SHALL BE AS FOLLOWS UNLESS NOTED OTHERWISE
UP DN
CO CO
CO
PANEL BOARD 1500mm ABOVE FINISHED FLOOR
LOCAL SWITCHES 1400mm ABOVE FINISHED FLOOR
CONVENIENCE OUTLET 300mm ABOVE FINISHED FLOOR
170mm ABOVE COUNTERS
CO AIRCON OUTLET 2000mm ABOVE FINISHED FLOOR
CO CO
EMERGENCY LIGHT 300mm BELOW FINISHED CEILING
C9
S44° 53'E, 8.86M

S44° 53'E, 8.86M

C8 7. ALL LOCAL SWITCHES TO BE CONNECTED SHALL BE RATED 15 AMPERES


CO C10 8. ALL ELECTRICAL INSTALLATIONS SHALL BE UNDER THE SUPERVISION OF A DULY
N44° 53'W, 11.27M

N44° 53'W, 11.27M


CO
LICENSED ELECTRICAL ENGINEER OR REGISTERED MASTER ELECTRICIAN
ACU ACU ACU ACU LEGEND
CO

SINGLE LINE DIAGRAM


CO
SYMBOL DESCRIPTION
15W LED PINLIGHT
ACU OVERHEAD SERVICE ENTRANCE
C7 EF
VTR EXHAUST FAN VTR 2-38 sq.mm THHN WIRE +
SERVICE DROP 1-14 sq.mm THHN WIRE (G)
BUILDING WALL
UP UP
CO
CONVENIENCE OUTLET
SECOND FLOOR LINE
125 AT, 60 Hz, 1Ø, 230V, 2P
S8

S8

AIRCON OUTLET

ACU BOLT ON TYPE CIRCUIT BREAKER


03

03
'E

'E

2-38 sq.mm THHN


,

,
2.

2.
99

99

RANGE OUTLET IN 38mmØ RSC


M

RANGE C1 20 AT 20 AT C2

C3 20 AT 20 AT C4
N46° 44'E, 9.91M N46° 44'E, 9.91M
LAUNDRY
LAUNDRY OUTLET METERING CONDUIT
C5 30 AT 30 AT C6
PANEL BOARD

REF
REFRIGERATOR OUTLET C7 40 AT 30 AT C8 KWHR
METER
C9 30 AT 30 AT C10
PB PANEL BOARD
C11 30 AT 30 AT C12

1.50m
1.80m
C13 30 AT spare
CIRCUIT RUN

GROUND 'CO' LAYOUT SECOND FLOOR 'CO' LAYOUT Sa 1 GANG SWITCH


ELECTRICAL GROUND FLOOR LINE

SCALE: 1:100M SCALE: 1:100M NATURAL GRADE LINE


S ab 2 GANG SWITCH GROUND
1-14 sq.mm BARE COPPER WIRE
IN 15mm O.C.
S abc 3 GANG SWITCH
DETAILS OF PANEL BOARD RISER DIAGRAM 16mmØ x 240mm LENGTH
SCALE: NTS GROUNDING ROD COPPERWELD
SCALE: NTS

DESIGNER / CONTRACTOR: DESIGNER / ENGINEER-IN-CHARGE: I M P O R T A N T: PROJECT TITLE: OWNER: REVISION/S: DATE/S: CADD BY: SHEET CONTENT/S: SHEET NO. :
LIGHTING LINE LAYOUT PLAN
POWER LINE LAYOUT PLAN
PROPOSED 2-STOREY RESIDENTIAL ELECTRICAL DETAILS E-01
CIVIL ENGINEER
PRC.NO.: PTR NO: PROJECT LOCATION: APPROVED BY OWNER: 08 08
VALIDITY: ISSUED ON: PROPOSED PLAN
TIN: ISSUED AT: ELECTRICAL PLAN