You are on page 1of 1

Regulated Design Record

Project Address:
NOTES
1. THIS DRAWING SHALL BE READ IN CONJUNCTION WITH
LOT 99 DP 1248789, 5 UHRIG THE STANDARD NOTES ON SHEET S0001 & S0002
2. REFER TO PLANS FOR TYPE MARK LOCATIONS
ROAD, LIDCOMBE 2141
Project Title:

STAGE 2 - 5 UHRIG ROAD,


LIDCOMBE
Consent No: DA/739/2019

Body Corporate Reg No: DEP0001482 200

Drawing Title:

COLUMN DETAILS - SHEET 2

COLUMN

TIES AT HALF NORMAL CENTRES


Drawing No: Revision:

FOR CIRCULAR & SQUARE


S0501 4

COLUMNS ONLY
LAP LENGTH
300x300x20 CAP PL
+ 2N16 U-BARS AT 200 CROSS CENTRES
Date DP
Rev Description Reg No 20mm NOMINAL NONI-SHRINK LEVELING GROUT IF REQUIRED
dd.mm.yy Full Name
P1 18.03.22 ISSUED FOR COORDINATION

50
P2 08.04.22 ISSUED FOR COORDINATION SLAB. REINFORCING NOT
CC2 DRAFT SHOWN FOR CLARITY

P3 29.04.22 ISSUED FOR COORDINATION 1:10 CRANKED BARS


STARTER BARS TO MATCH UPPER
- CC2 DRAFT COLUMN REINFORCING SLAB. REINFORCEMENT NOT 300 COG ALL
1 29.05.22 FOR CONSTRUCTION NICHOLAS DEP0000289 SHOWN FOR CLARITY COLUMN BARS
MORPHETT
3 TIES AT 75 CENTRES
2 08.06.22 FOR CONSTRUCTION NICHOLAS DEP0000289 AT CRANKED BARS 3 TIES IN SLAB
MORPHETT
3 22.05.23 FOR CONSTRUCTION

50
4 09.08.23 FOR CONSTRUCTION NICHOLAS DEP0000289 2 TIES AT 75mm CENTRES
MORPHETT 20 BASE PL, 5CFW TO 1SC1
4-M16 HILTI HAS-U 5.8 THREADED ANCHOR RODS
130 MIN EMBEDMENT INTO CONCRETE
WITH HIT-RE 500 V4 EPOXY
2 TIES AT
75mm CENTRES

BARS CONTINUE THROUGH CONTINUOUS BARS FROM BELOW

Project Number: 21026 Date Issued: 09.08.23

Status:
FOR CONSTRUCTION
50 250 50

COLUMN TRANSITION DETAIL - BETWEEN SLABS - T2 COLUMN


CONSULTING STRUCTURAL ENGINEERING DRAWINGS
Print reduction bar:
SCALE 1:20
TYPICAL STEEL COLUMN CONNECTION DETAIL
DESIGNED N. Morphett
1 : 10
0 10 20 30 40 50
DRAWN S. Thompson
FULL SIZE SHEET SIZE A1
CHECKED J. Salhani
COLUMN TRANSITION DETAIL - TERMINATE
Consulting Structural Engineer :
SCALE 1:20

COLUMN

TIES AT HALF NORMAL CENTRES


FOR CIRCULAR & SQUARE
COLUMNS ONLY
www.jsbcconsulting.com COLUMN COLUMN
LAP LENGTH

Developer :

NORMAL CENTRES
OVER LAP LENGTH
NORMAL CENTRES
OVER LAP LENGTH

TIES AT HALF
LAP LENGTH
TIES AT HALF
LAP LENGTH
50

COLUMN SLAB. REINFORCING NOT


COG WALL BARS WHERE
SHOWN FOR CLARITY
NO COLUMN OVER
TIES AT HALF NORMAL CENTRES

1:10 CRANKED BARS 300 COG WALL BARS


FOR CIRCULAR & SQUARE

WHERE NO COLUMN OVER


3 TIES AT 50 CENTRES
COLUMNS ONLY

AT CENTRE OF BEAM/SLAB
Architect :
LAP LENGTH

3 TIES AT 75 CENTRES
AT CRANKED BARS SLAB. REINFORCING NOT SLAB. REINFORCING NOT

50
50
SHOWN FOR CLARITY SHOWN FOR CLARITY
SLAB or FOOTING
50

REINFORCING NOT SHOWN


50

FOR CLARITY 2 TIES AT 75mm CENTRES STARTER BARS TO MATCH


UPPER COLUMN REINFORCING
3 TIES AT 50 CENTRES
AT CENTRE OF BEAM/SLAB

300 COG
LOCATE STARTERS ON BOTTOM
STARTER BARS REINFORCEMENT OF SLAB
SIZE AND SPACING
TO MATCH COLUMN CONTINUOUS BARS FROM
REINFORCEMENT CONTINUOUS BARS FROM BELOW
INSITU CONCRETE WALL BELOW

300 COG
WALL
Key Plans: 2 TIES LOCATE STARTERS ON BOTTOM CONTINUOUS BARS FROM
SIZE TO MATCH COLUMN REINFORCEMENT OF SLAB INSITU CONCRETE WALL BELOW
ZONE B ZONE A TIES, SPACING AS SHOWN.
TH

ZONE D ZONE C
COLUMN TRANSITION DETAIL - BASE COLUMN TRANSITION DETAIL - BETWEEN SLABS - T1 COLUMN TRANSITION DETAIL - WALL TO COLUMN TYPE 2 COLUMN TRANSITION DETAIL - WALL TO COLUMN TYPE 1
N OR

SCALE 1:20 SCALE 1:20 SCALE 1:20 SCALE 1:20


ZONE F ZONE E

BASEMENT KEY PLAN

TOWER 2 TOWER 1
COMMERCIAL

TOWER 5

TOWER
TOWER 4
3

TOWER KEY PLAN