FOOTING SCHEDULE (M30:Fe500)

NC5
-
NC3
NOTE:
400X400 FOOTING DIMENSION FOOTING REINFORCEMENT
REFER DRAWING NO STS/YYXXXXX/GN/------ TO STS/YYXXXXX/GN/------ FOR
NC2
COLUMN FOOTING REMARKS
NC1 BOTTOM GENERAL RCC NOTES & TYPICAL DETAILS
400X400 450X450 NUMBERS TYPE L B D
ALONG B ALONG L T10@200C/C SHEAR CONNECTOR
NOMINAL COVERS
TO BE ANCHORED IN EXISTING SR NO. DESCRIPTION MILD MODERATE SEVERE

1200X1200 1200X1200 NC1,NC3,NC6,NC8 Pad 1200 1200 400 T10@150 C/C T10@150 C/C - FOOTING FOR MIN. 175MM BY
1 FOOTINGS 50 50 50
1400X1400 DRILLING & GROUTING HILTI
WORTH RE500. 2 COLUMNS & WALLS >200MM WIDTH
40 40 45
PLUM CONCRETE (TO LINKS OF COLUMN)
EXISTING FOOTING COLUMNS & WALLS WITH WIDTH OF 200MM
NC2,NC4,NC5,NC7 Pad 1400 1400 450 T10@125 C/C T10@125 C/C - & BELOW HAVING REINF. OF DIA. 16MM &
3 40 40 45
ABOVE. (TO LINKS OF COLUMN)
COLUMNS & WALLS WITH WIDTH OF 200MM
150THK PCC 4 & BELOW HAVING REINF. OF DIA. 12MM. 25 30 45
(TO LINKS OF COLUMN)
BEAM SCHEDULE SECTION A-A
5 SLABS 20 30 45
6 BEAMS (TO STIRRUPS OF BEAM) 20 30 45

BEAM SIZE BOTTOM REINFORCEMENT TOP REINFORCEMENT SHEAR STIRRUPS 7 LIFT WALLS 40 40 45
DEVELOPMENT LENGTH
REMARKS
NUMBERS B D LEFT MID SPAN RIGHT LEFT MID SPAN RIGHT LEFT MID SPAN RIGHT
REINF. GRADE M20 M25 M30 M35 M40 & ABOVE
FE 500D 57 X D 49 X D 46 X D 40 X D 36 X D

IMPORTANT NOTES:
NB1,NB3 300 750 3-T20 +3-T20 3-T20 +3-T16 3-T16 +3-T16 2L-T10 @ 150 C/C 2L-T10 @ 150 C/C 2L-T10 @ 150 C/C 2-T8 S.F.R.
NC4 3-T16 2-T16 2-T16 THE USE OF THIS DRAWING FOR CONSTRUCTION SHALL EXPLICITLY CONFIRM THE OWNER'S/
NC5 ON EACH FACE BUILDER'S/CONTRACTOR'S ACCEPTANCE OF THE FOLLOWING CONDITIONS.
450X450

EXISTING FOOTING
1. OUR RESPONSIBILITY SHALL BE LIMITED TO SAFE AND SOUND STRUCTURAL DESIGN AS
450X450 300 750 3-T20
NB2,NB4 +3-T20 3-T20 +3-T16 3-T16 +3-T16 2L-T10 @ 150 C/C 2L-T10 @ 150 C/C 2L-T10 @ 150 C/C 2-T8 S.F.R. EXPRESSED IN THIS DRAWING, AND WE WILL NOT BE HELD LIABLE FOR,
A A 3-T16 2-T16 2-T16 ON EACH FACE a. OLD STRUCTURES SAFETY DURING DEMOLITION

b. SAFETY OF ANY NEIGHBORING BUILDING/PERSONS STAYING IN NEIGHBORING BUILDING/


NB5,NB7 300 750 3-T20 +3-T20 3-T20 +3-T16 3-T16 +3-T16 2L-T10 @ 150 C/C 2L-T10 @ 150 C/C 2L-T10 @ 150 C/C 2-T8 S.F.R. PERSONS AND PROPERTIES ON NEIGHBORING ROADS
1400X1400 1400X1400 3-T16 2-T16 2-T16 ON EACH FACE c. WORKPLACE SAFETY FOR CONSTRUCTION WORKERS/ALL PERSONNEL DURING CONSTRUCTION.

d. CORRECTNESS/SAFETY OF ANY TEMPORARY STRUCTURE, SCAFFOLDING, SHUTTERING,

NB6,NB8 300 750 3-T20 +3-T20 3-T20 +3-T16 3-T16 +3-T16 2L-T10 @ 150 C/C 2L-T10 @ 150 C/C 2L-T10 @ 150 C/C 3-T8 S.F.R. CENTERING ERECTED ON SITE, AND ANY PERSONNEL INJURY RESULTING FROM ANY ACCIDENT
3-T16 2-T16 2-T16 ON EACH FACE e. ANY ACCIDENT CAUSED BY PREMATURE DESHUTTERING, FAULTY / SUBSTANDARD
CONSTRUCTION MATERIAL OR WORKMANSHIP / FAULTY CONSTRUCTION PROCEDURE.

NB9,NB12 300 900 3-T25 +3-T25 3-T25 +3-T20 3-T20 +3-T20 2L-T10 @ 125 C/C 2L-T10 @ 200 C/C 2L-T10 @ 125 C/C 3-T8 S.F.R. f. ANY ACCIDENT CAUSED BY THE CONSTRUCTION OF BUILDING ELEMENTS NOT DESIGNED BY US.

3-T20 3-T16 3-T16 ON EACH FACE 2. THIS DRAWING SHALL NOT BE USED FOR ANY CONSTRUCTION UNLESS THE OWNER/
BUILDER/ARCHITECT OBTAINS THE NECESSARY STATUTORY APPROVALS FROM REGULATING
AUTHORITIES.
NB10,NB11 300 900 3-T25 +3-T25 3-T25 3-T20 3-T20 3-T20 2L-T10 @ 125 C/C 2L-T10 @ 200 C/C 2L-T10 @ 125 C/C 3-T8 S.F.R.
3-T20 ON EACH FACE
3. WE ARE INDEMNIFIED FROM ANY LEGAL LIABILITY IN THE EVENT OF UNAUTHORIZED
CONSTRUCTION.

4. SUPERVISION WILL BE PROVIDED TO THE EXTENT OF VERIFICATION OF REINFORCEMENT ON SITE


NB13,NB14 450 900 4-T25 +4-T25 4-T25 +4-T25 4-T25 +4-T25 4L-T12 @ 150 C/C 4L-T12 @ 150 C/C 4L-T12 @ 150 C/C 3-T10 S.F.R. IF SPECIFICALLY REQUESTED, BUT RESPONSIBILITY REGARDING CORRECT & SOUND
4-T25 4-T25 4-T25 ON EACH FACE CONSTRUCTION SHALL SOLELY REST WITH CONTRACTOR/ BUILDER / OWNER.

400X400 400X400 5. ALL STRUCTURAL CONCRETE SHOULD BE WEIGH BATCHED, MIXED IN A MACHINE, AND

NC6 NC8 NB15,NB16,NB17 300 750 3-T20 +3-T20 3-T20 +3-T16 3-T16 +3-T16 2L-T10 @ 150 C/C 2L-T10 @ 150 C/C 2L-T10 @ 150 C/C 2-T8 S.F.R. VIBRATED MECHANICALLY.

NB18 3-T16 2-T16 2-T16 ON EACH FACE 6. BEFORE CONSTRUCTION, ANY DISCREPANCY BETWEEN OUR DRAWING AND THE ARCHITECTS'
DRAWING SHALL BE BROUGHT TO OUR ATTENTION.

450X450 THIS DRAWING IS PROPERTY OF STS CONSULTANTS LLP,AND SHALL NOT


BE REPRODUCED OR USED WITHOUT WRITTEN PERMISSION.
NC7
1200X1200 1400X1400 1200X1200 SLAB SCHEDULE M30 : Fe500 , COVER = 40MM M30 : Fe500 , COVER = 40MM SIGNATURE & STAMP - STS CONSULTANTS LLP SIGNATURE & STAMP - ARCHITECT OF RECORD

RCC PLAN FOR COLUMN & FOOTING SLAB THICKNESS


STEEL ALONG SPAN STEEL ACROSS SPAN SLAB TYPE REMARKS
NUMBER (MM)
DRAWING TO BE VALIDATED BY ARCHITECT ON RECORD
DRAWING IS VALID FOR DESIGN ADEQUACY PROVIDED THAT AFTER CHECKING COMPLIANCE WITH APPROVED PLANS
S1 200 T10 @ 150 C/C ALL STR. @ BTM. T8 @ 150 C/C DIST. DESIGNED FOR FIRE IT IS SIGNED & STAMPED BY OUR OFFICE FROM THE REGULATING LOCAL GOVERNMENT AUTHORITY.
ONE WAY

400

450
T10 @ 150 C/C ALL STR. @ TOP @ TOP & BTM. TENDER LOAD. R10

T12 T16 R9
S2 230 T12 @ 150 C/C ALL STR. @ BTM. T10 @ 150 C/C DIST. ONE WAY DESIGNED FOR FIRE
NC1 NC2 400 450
NB1 NB2 T10 @ 150 C/C ALL STR. @ TOP @ TOP & BTM. TENDER LOAD. R8
L R L R NC3 8-T12 8-T16
R R7
R
R

R
L
L

400X400 450X450 R6
S1

S1

NC1,NC3,NC6,NC8 NC2,NC4,NC5,NC7
5 NB R5
1 16
NB COLUMN SCHEDULE COLUMN SCHEDULE R4

R3 25.12.2023
R
S1

S1

R2 22.12.2023
L 9
NB8
NB6

NB
R

R1 - ----- ----- 16.05.2023


NB
14

REV NO. REVISIONS BY CHKD. DATE

E.
MAX. SLOPE

OR
1:6 COLUMN

M
ER 0d
IS
GRADE OF CONCRETE : M30 GRADE OF STEEL : FE 500d

EV R 1
S2

TIE BEAM
R

CH O
HI m
EXPOSURE CONDITION : MILD SAFE BEARING CAPACITY : -- kN/m2
0

W 5m
1

LD

LD
NB

7
LIVE LOAD : -- kN/m2 FLOOR FINISH : -- kN/m2

BEAM DEPTH
TYPICAL LINK DETAILS DRAWING STATUS
CERTIFIED FOR DESIGN ADEQUACY
L

AT ANY LEVEL WHERE COLUMN SIZE


L

L
S2

100
NC5 DRAWN BY DESIGNED BY CHECKED BY DATE
R GETS REDUCED IN EITHER DIMENSION,
NC4
R
L

P.C.C. PRIYANKA SVC NRP 07.01.2022


R

11 BEAM IS ABSOLUTELY ESSENTIAL


NB TYPICAL BOX FOOTING DETAIL BEAM PROJECT NO BUILDING NO DRAWING NO REVISION
20:0119 ----- 200119-511 R0
CLIENT
L
S2

L/3 L
L/3 L/3
MAGNUM
NB5

LEFT SUPPORT MID SPAN RIGHT SUPPORT


DESIGN ARCHITECT
NB

MID HEIGHT
13

MIN.TWO BARS IN ONE PIECE


NB7

JAY AERAM
12
NB
R STAGGERED LAPPING
L

ARCHITECT OF RECORD
S1

L
S1

LD

JAY AERAM
LD

LD
LD
NB PROJECT
17 18
NB PROPOSED PROJECT AT GAT NO.659(P1+P2)
L/6 L/6 KESNAND,PUNE
S1

DRAWING TITLE

BEAM DEPTH
S1

SINGLE SPAN FRAME BEAM


NB3 L NB4 L RCC PLAN FOR WELL COVERING SLAB
R
R

L
L

L R L R

NC6 NC7 NC8


SLAB
THK.

SLAB SLAB
R BEAM

RCC PLAN FOR WELL COVERING SLAB www.stsconsultantsllp.com


BEAM
BEAM BEAM
PUNE OFFICE ADDRESS MUMBAI OFFICE ADDRESS

L 1.25 MM THK CRILL DECK SHEET TYPICAL DETAIL OF REINFORCEMENT


C3/103-104, SOUDAMINI COMMERCIAL,
COMPLEX, RIGHT BHUSARI COLONY,
FIRST FLOOR , ALANKAR BUILDING,
SARDAR VALLABHBHAI PATEL ROAD,
DETAIL FOR DECK SLAB
L R AND LINKS FOR COLUMNS KOTHRUD, PUNE - 38.
TEL. +91 20 41270956
GIRGOAN, MUMBAI 400004
TEL. +91 9923056243