You are on page 1of 1

Code: CP-AG-LG-STR-VT-03 Scale: as indicated Revision: 00

STANDING SEAM SYSTEM: VENTILATED ROOF WITH CONCRETE


COVER SLAB
The insulation layer is installed on the concrete cover slab forming a continuous plane
directly below the roof cladding.

7 5

1. zintek® standing seam roof cladding


2. Acoustic insulation draining filament mat thickness 8 mm
3. Grooved wooden board
4. Ventilated cavity made with wooden battens
5. Continuous seal
6. Breathable waterproofing membrane
7. Thermal and acoustic insulation
8. Vapour barrier to be verified by specific thermo-hygrometric assessments
9. Concrete cover slab

SUBJECT: ROOF STRATIGRAPHY

SPECIFICATIONS: Roof solutions - Standing seam system - Wood support

Zintek Srl – Via delle Industrie 22


Porto Marghera – Venice – ITALY
ph +39 041 290 18 66 – zintek@zintek.it – www.zintek.it