You are on page 1of 9

Ver. 01.

01
Table of content:

Parts List ……………………………………………………………………………………………………………………………….…………… 2

Inverter Unit Installation Setup…………………………………………………………………………………………….……………. 3

Cables Installation Guides …………………………………………………………………………………………………….…………… 5

Trouble shooting and fault codes ………………………………………………………………………………………….…………… 8

1 54” PM FAN INVERTER


Parts List

No. Image Parts No. Description qty/unit Remarks

PM Motor Inverter For 1.5KW


1 FN8000100 1 set
TECO-F510 PMAC MOTOR

2 FN0910004 Inverter wall seat bracket 1 pcs

For inverter
3 HR134003012 Screw M3*12 4 pcs
bracket

For inverter
4 HR131010034 Drilling Screw 4 pcs
bracket

54” PM FAN INVERTER 2


Inverter Unit Installation Setup

1. Attaching wall bracket for inverter unit

Drilling Screw: 4 pcs

2. Attaching Inverter unit to wall bracket


Screw M3x12

Insert screw
half-through.

3 54” PM FAN INVERTER


Attach inverter
into wall bracket

Make sure the inverter is in


place and fasten the screw

54” PM FAN INVERTER 4


Cables Installation Guide

1. Power input and Motor cable

Electricity power input 220 VAC single/three phase


To reverse direction
Cable size specification cannot be lower than 2.0sqmm
of motor rotation
swap any two leads

GROUND
GROUND

R S T U V W
PM MOTOR
Single/Three
phase power
input 220V

! DANGER !
Do not apply power until all connections are correct and secure, and
all protective covers are in place

PM Motor Cable
U V
W

GROUND
Thermostat protection

! IMPORTANT !
Fan MUST be completely assembled with butterfly shutter
before connecting motor cable to inverter.
5 54” PM FAN INVERTER
2. Control Signal Connection

False Start Module


Auto restart: 5 attempts

Dry
Contact

54” PM FAN INVERTER 6


! WARNING !
These buttons CANNOT be pressed in order to avoid
malfunction. All setting has been pre-installed.

3. Fan Speed Setup


Speed setup has been pre-installed.
Main frequency command: REVERSE (Negative characteristic). 0 ~ 10V corresponding to 100 ~ 0%

Min. Speed: 144 RPM Max. Speed: 715 RPM

4. Alarm Signal
The connection of this alarm signal is dry contact.
The alarm relay is OPENED under all normal conditions.

7 54” PM FAN INVERTER


Trouble Shooting and Fault Codes

Fault detection is diagnosed into 2 modules.


1. False Start Module

Module Description Restart Restart Condition Attempts


Fault Start Module – - Failed motor start Auto 10 seconds timeout before 5
LED display number - Loss of synchronism start.
with motor

Fault Start Module - Restart attempts has Manual Turn off inverter and check -
RED LED ON reached 5 times limit. fan.

Possible causes:
- Blade spinning in
reverse direction above
290 RPM
- Over limit current

2. Inverter Module (LED interface is required to display fault codes).


Other than above faults,
Please refer to inverter F510 fault table code for possible causes and take appropriate measures

54” PM FAN INVERTER 8