Professional Documents
Culture Documents
SYMPTOM:
SC900 (electrical total counter error) occurs if a copy job is performed after the NVRAM is replaced.
CAUSE:
Some of the initial data that is normally programmed in the NVRAM was missing in P/N D1209590.
SOLUTION:
When replacing the NVRAM use the latest part number (below).
GENERAL:
The following part information is being issued for all D120/D121/D122/D139/D140/D141 Parts Catalogs.
14
101
1
2 101
3
101
5
4
REFERENCE
OLD PART NO. NEW PART NO. DESCRIPTION QTY INT PAGE ITEM
D1209590 D1209591 NVRAM 1 1 73 2
UNITS AFFECTED:
The serial number cut-in information was not available at time of this publication.
INTERCHANGEABILITY CHART:
OLD and NEW parts can be used in both OLD and NEW parts CAN NOT be used in OLD machines.
0 NEW machines.
2 OLD parts can be used in OLD and NEW machines.
NEW parts can be used in OLD and NEW machines. OLD parts CAN NOT be used in NEW machines.
1 OLD parts CAN NOT be used in NEW machines.
3 NEW parts CAN NOT be used in OLD machines.
Must be installed as a set on units manufactured prior to the S/N cut-in. On units manufactured after the S/N cut-in or
3/S previously modified, use the new part numbers individually.
Page 2 of 2