You are on page 1of 2

TECHNICAL SERVICE BULLETIN

BULLETIN NUMBER: D120/D121/D122/D139/D140/D141 - 005 6/5/2012


APPLICABLE MODEL:
LANIER – MP 2352P/MP 2852/MP 3352/MP 2352SP/MP 2852/MP 3352
RICOH – AFICIO MP 2352P/MP 2852/MP 3352/MP 2352SP/MP 2852/MP 3352
SAVIN – MP 2352P/MP 2852/MP 3352/MP 2352SP/MP 2852/MP 3352

SUBJECT: SC900 OCCURS AFTER NVRAM REPLACEMENT

SYMPTOM:
SC900 (electrical total counter error) occurs if a copy job is performed after the NVRAM is replaced.

CAUSE:
Some of the initial data that is normally programmed in the NVRAM was missing in P/N D1209590.

SOLUTION:
When replacing the NVRAM use the latest part number (below).

GENERAL:
The following part information is being issued for all D120/D121/D122/D139/D140/D141 Parts Catalogs.

14

101
1

2 101

3
101
5
4
REFERENCE
OLD PART NO. NEW PART NO. DESCRIPTION QTY INT PAGE ITEM
D1209590 D1209591 NVRAM 1 1 73 2

Copyright © 2012 RICOH Americas Corporation. All rights reserved. Page 1 of 2


Tech Service Bulletin No. D120/D121/D122/D139/D140/D141 - 005

UNITS AFFECTED:
The serial number cut-in information was not available at time of this publication.

INTERCHANGEABILITY CHART:
OLD and NEW parts can be used in both OLD and NEW parts CAN NOT be used in OLD machines.
0 NEW machines.
2 OLD parts can be used in OLD and NEW machines.
NEW parts can be used in OLD and NEW machines. OLD parts CAN NOT be used in NEW machines.
1 OLD parts CAN NOT be used in NEW machines.
3 NEW parts CAN NOT be used in OLD machines.
Must be installed as a set on units manufactured prior to the S/N cut-in. On units manufactured after the S/N cut-in or
3/S previously modified, use the new part numbers individually.

Page 2 of 2