ALLEY

390 E CORPORATE DRIVE STE 112


padRe

MERIDIAN, ID 83642
#208-283-3775
PROPERTY LINE
81.00'

8 Are

5'-0"
s
SETBACK

NEW ADDITION

A
NEW ADDITION

EXISTING
FOUNDATION

EXISTING STRUCTURE

15'-5" 42'-1"

ALPAUGH REMODEL
EXISTING STRUCTURE

SETBACK
O Kees

Design. These drawings are NOT to be reproduced,


12'-0"
SETBACK

These Drawings contain confidential proprietary


information and are the property of Risen Home

construction or any other purpose without prior


written permission from Risen Home Design.
CALDWELL, ID 83605

copied whole or in part, disclosed, used for


PROPERTY LINE

1603 E. BEECH ST.


new
3D VIEW
2
15'-0"
PROPERTY LINE

SITE PLAN
IOWA AVE.

Layout

132.19'
132.19'

REVISIONS

10/4/2023
DATE
EXISTING STRUCTURE
5'-0"

1
NEW ADDITION

Shifneeded
SETBACK
EXISTING STRUCTURE
2
20'-0"

ISSUE FOR CONSTRUCTION


3D VIEW-1
3

DESCRIPTION
81.00' PROPERTY LINE

NO.
PISTE

0
SHEET TITLE
SITE PLAN

E. BEECH ST.
GENERAL CONDITIONS
DRAWINGS & SPECIFICATIONS RHD PROJECT NUMBER: RHD-990
IT IS THE INTENT OF THE DRAWINGS AND SPECIFICATIONS TO BE GUIDELINES
SITE PLAN NOTE: RISEN HOME DESIGN PLANS DO NOT CARRY AN
FOR CONSTRUCTION. THE CONTRACTOR IS RESPONSIBLE FOR DETERMINING DRAWN BY: LDL DATE: 10/3/2023
1 1/8" = 1'-0"
ENGINEER'S AND/OR ARCHITECT'S STAMP(S) SOME
ANY QUESTIONS AND MEANINGS IN THE WORKING DRAWINGS AND
SPECIFICATIONS AND THE CONTRACTOR SHALL NOTIFY THE DESIGNER IN
CHECKED BY: MM DATE: 10/3/2023
CONDITIONS MAY ARISE DURING DESIGN. AND/OR DRAWING NUMBER: REV:
WRITING OF ANY ERRORS, OMISSIONS, OR UNSUITABLE DETAILING WHICH MAY
CONSTRUCTION THAT MAY REQUIRE AN ARCHITECT'S AND/OR
CAUSE CONSTRUCTION PROBLEMS. THE DESIGNER'S LIABILITY REGARDING
A1.0 0
ENGINEER'S STAMP TO COMPLY WITH LOCAL BUILDING
ERRORS AND/OR OMMISSIONS WILL BE LIMITED TO THE CORRECTION OF THE
CODES. THE CONTRACTOR IS TO VERIFY THESE CONDITIONS
ORIGINAL DRAWINGS. CONSULTANT'S LITABILITY IS THE SAME.
AND SECURE REQUIRED STAMPS PRIOR TO CONSTRUCTION
390 E CORPORATE DRIVE STE 112
MERIDIAN, ID 83642
#208-283-3775
A3.0

Ef
11'-3" 8'-6" 3'-2 1/2" 13'-4"

23'-6"
11'-8"
TT yuEiied

23'-6"

23'-6"
To
A3.0 3 STORAGE
4 A3.0

10'-4"
8'-7"
11'-10"

1st FLOOR PLAN - EXISTING


ALPAUGH REMODEL

Design. These drawings are NOT to be reproduced,


These Drawings contain confidential proprietary
information and are the property of Risen Home

construction or any other purpose without prior


written permission from Risen Home Design.
CALDWELL, ID 83605

copied whole or in part, disclosed, used for


FRONT VIEW - EXISTING
2

1603 E. BEECH ST.


Existing
1/4" = 1'-0"

new
22'-11 1/2" 13'-4"

A3.0

1st FLOOR PLAN - EXISTING


1 1/4" = 1'-0"
REVISIONS

9/28/2023
10/4/2023
DATE
3
LEFT VIEW - EXISTING
1/4" = 1'-0"

if
4
RIGHT VIEW - EXISTING
1/4" = 1'-0"
0

ISSUE FOR PRELIMINARY REVIEW


ISSUE FOR CONSTRUCTION
DESCRIPTION
NO.
A
0
SHEET TITLE
1st FLOOR
PLAN
BACK VIEW - EXITING EXISTING
5 1/4" = 1'-0"
GENERAL CONDITIONS
DRAWINGS & SPECIFICATIONS RHD PROJECT NUMBER: RHD-990
IT IS THE INTENT OF THE DRAWINGS AND SPECIFICATIONS TO BE GUIDELINES
FOR CONSTRUCTION. THE CONTRACTOR IS RESPONSIBLE FOR DETERMINING DRAWN BY: RMC DATE: 9/28/2023
NOTE: RISEN HOME DESIGN PLANS DO NOT CARRY AN
ANY QUESTIONS AND MEANINGS IN THE WORKING DRAWINGS AND
ENGINEER'S AND/OR ARCHITECT'S STAMP(S) SOME CHECKED BY: MM DATE: 9/28/2023
SPECIFICATIONS AND THE CONTRACTOR SHALL NOTIFY THE DESIGNER IN
CONDITIONS MAY ARISE DURING DESIGN. AND/OR DRAWING NUMBER: REV:
WRITING OF ANY ERRORS, OMISSIONS, OR UNSUITABLE DETAILING WHICH MAY
CONSTRUCTION THAT MAY REQUIRE AN ARCHITECT'S AND/OR
CAUSE CONSTRUCTION PROBLEMS. THE DESIGNER'S LIABILITY REGARDING
A3.0 0
ENGINEER'S STAMP TO COMPLY WITH LOCAL BUILDING
ERRORS AND/OR OMMISSIONS WILL BE LIMITED TO THE CORRECTION OF THE
CODES. THE CONTRACTOR IS TO VERIFY THESE CONDITIONS
ORIGINAL DRAWINGS. CONSULTANT'S LITABILITY IS THE SAME.
AND SECURE REQUIRED STAMPS PRIOR TO CONSTRUCTION
FLOOR PLAN NOTES

25 O

390 E CORPORATE DRIVE STE 112


1. ALL STRUCTURAL LUMBER SIDED FOR #2 OR BETTER DOUG FIR LARCH.
2. 2x EXTERIOR STUD FRAMING @ 16' O.C. W/ SINGLE BOTTOM PLATE AND

MERIDIAN, ID 83642
DOUBLE TOP PLATE.

#208-283-3775
3. 4x8 HEADERS IN ALL BEARING WALL OPENING UNLESS OTHERWISE
NOTED.

11
A4.0
1-1 1-2 4. ALLOW FOR A 22' x 30' (MIN) ATTIC AND CRAWL SPACE ACCESS.

t.ae
5. ALL METAL CONNECTIONS TO BE SIMPSON CO. OR BETTER
2 6. 5/8" TYPE 'X' GYP BOARD @ ALL GARAGE COMMON WALLS AND CEILINGS
25'-3 1/2" 13'-0 1/2" APPLIED TO GARAGE SIDE AND ALL WALLS, BEAMS, POSTS AND OTHER
STRUCTURAL MEMBERS SUPPORTING FIRE PROTECTED HORIZONTAL
7'-0" 11'-3 1/2" 7'-0" STRUCTURAL MEMBERS.
7. DOORS BETWEEN GARAGE AND DWELLING ARE TO BE SELF CLOSING
AND TIGHT FITTING SOLID WOOD DOOR 1 3/8" THICK OR A DOOR W/ A FIRE
WSP WSP PROTECTION RATING OF NOT LESS THAN 20 MINUTES.
B-1 40/40 SL 40/40 SL
(2) 1 3/4'' x 11 7/8''
8. 1/2" GYPSUM BOARD TO BE INSTALLED ON INSIDE WALLS OF HOUSE.
(2) 2x10 (2) 2x10 9. ALL WINDOWS TO HAVE BREATHER TUBES INSTALLED.

2'-0"
6x6 P.T.
POST (TYP.) 10. ROOF SYSTEM TO BE PRE-ENGINEERED MANUFACTURED ROOF TRUSSES

4'-0"

4'-0"
WSP
UNLESS OTHERWISE NOTED.
NEW 2x6 WALLS @ 16'' o.c. 28 11. ALL CONSTRUCTION PRACTICES USED IN THE CONSTRUCTION OF THIS

2'-0"
DWELLING SHALL BE DONE IN ACCORDANCE W/ THE 2018 WHERE
RAILING
APPLICABLE.

STAIRS UP
12. VENT RANGE HOOD, FANS, AND DRYER TO OUTSIDE AIR CONTRACTOR TO
VERIFY ALL CONDITIONS AND DIMENSIONS PRIOR TO COMMENCING
WORK.
13. ALL RESCUE WINDOWS FROM SLEEPING AREAS MUST MEET
THE FOLLING REQUIREMENTS:
1. SHALL HAVE A NET CLEAR OPENING OF 5.1 SQ. FT.
2. MINIMUM HEIGHT OF 24".
3. MINIMUM WIDTH OF 20".

11'-8 3/4"
4. FINISHED SILL HEIGHT OF NOT MORE THAN 44".
14. EXTERIOR DIMENSIONS ARE TO FACE OF STUD WALL. INTERIOR
DIMENSIONS ARE TO FACE OF STUD WALL.
15. ALL FURNACE SWITCHES, PILOTS, AND BURNERS TO BE MINIMUM 18"
EXISTING STRUCTURE (TYP.) ABOVE FINISHED FLOOR.
25'-0"

WSP
27'-6"

I in
GARAGE SQ/FT.
9' CEILING
(E) STORAGE NEW GARAGE 698 SF
3 A4.0
A4.0 4 NEW BONUS ROOM 789 SF

3'-10 1/4"

ALPAUGH REMODEL
EXISTING STORAGE 313 SF

Design. These drawings are NOT to be reproduced,


These Drawings contain confidential proprietary
information and are the property of Risen Home

construction or any other purpose without prior


3'-6"

written permission from Risen Home Design.


CALDWELL, ID 83605

copied whole or in part, disclosed, used for


DOOR/WINDOW TAG EXAMPLE

1603 E. BEECH ST.

1st FLOOR - NEW


DOOR TAG WINDOW TAG

7'-11"
26 = 2'-6" 40/56 SH = 4'-0" x 5'-6" SINGLE HUNG
WSP

(2) 18'' LVL'S


A-1
line
200/80 OVERHEAD DR
PFG PFG NOTE: VERIFY ALL WINDOW/DOOR ROUGH OPENING AND
2'-6" 20'-0" 2'-6" HEADER HEIGHT AND THE SAME FOR TRIM PACKAGE. VERIFY
STANDARD HEIGHTS WITH CONTRACTOR BEFORE FRAMING.

property
25'-0" 13'-4"

3 to
NEW EXISTING
1 SEE 2018 IRC

win
R302.7 PROVIDE UNDERSTAIR PROTECTION AS REQUIRED
A4.0
R302.11 PROVIDE FIREBLOCKING AS REQUIRED
R303.7 PROVIDE SWITCHING AND ILLUMINATION AS REQUIRED
REVISIONS

9/28/2023
10/4/2023
R305 PROVIDE SUFFICIENT CEILING HEIGHTS
1st FLOOR PLAN - NEW

DATE
R311.7 MEET STAIRWAY REQUIREMENTS
1 1/4" = 1'-0"
R312 MEET GUARD REQUIREMENTS

IIII
38'-5"
6'-3 1/2"

37'-9"

7'-9 1/2"
40/40 SL

STAIRS DOWN
40/40 SL
BONUS ROOM

ISSUE FOR PRELIMINARY REVIEW


9' CEILING

I
20'-7"

20'-0"

20'-7"
8'-0"

6'-2 1/2"

ISSUE FOR CONSTRUCTION


28
40/40 SL

DESCRIPTION
RAILING
6'-3 1/2"

6'-7"

NO.
A
0
Truss Layout
SHEET TITLE
2nd FLOOR PLAN NEW 1st FLOOR
2 1/4" = 1'-0" NEW

GENERAL CONDITIONS
DRAWINGS & SPECIFICATIONS RHD PROJECT NUMBER: RHD-990
IT IS THE INTENT OF THE DRAWINGS AND SPECIFICATIONS TO BE GUIDELINES
FOR CONSTRUCTION. THE CONTRACTOR IS RESPONSIBLE FOR DETERMINING DRAWN BY: RMC DATE: 8/29/2023
NOTE: RISEN HOME DESIGN PLANS DO NOT CARRY AN
ANY QUESTIONS AND MEANINGS IN THE WORKING DRAWINGS AND

0
ENGINEER'S AND/OR ARCHITECT'S STAMP(S) SOME CHECKED BY: MM DATE: 8/29/2023
SPECIFICATIONS AND THE CONTRACTOR SHALL NOTIFY THE DESIGNER IN
CONDITIONS MAY ARISE DURING DESIGN. AND/OR DRAWING NUMBER: REV:
WRITING OF ANY ERRORS, OMISSIONS, OR UNSUITABLE DETAILING WHICH MAY
CONSTRUCTION THAT MAY REQUIRE AN ARCHITECT'S AND/OR
CAUSE CONSTRUCTION PROBLEMS. THE DESIGNER'S LIABILITY REGARDING
A3.1 0
ENGINEER'S STAMP TO COMPLY WITH LOCAL BUILDING
ERRORS AND/OR OMMISSIONS WILL BE LIMITED TO THE CORRECTION OF THE
CODES. THE CONTRACTOR IS TO VERIFY THESE CONDITIONS
ORIGINAL DRAWINGS. CONSULTANT'S LITABILITY IS THE SAME.
AND SECURE REQUIRED STAMPS PRIOR TO CONSTRUCTION
390 E CORPORATE DRIVE STE 112
R806 - PROVIDE ADEQUATE ATTIC VENTILATION.

MERIDIAN, ID 83642
#208-283-3775
NEW ROOF
NEW ROOF
(APPROX. HEIGHT)
22'-11 1/2"

nothing
(N) NEW ADDITION

(E) (N)

ALPAUGH REMODEL
(N)
(E)

Design. These drawings are NOT to be reproduced,


EXISTING STRUCTURE

These Drawings contain confidential proprietary


information and are the property of Risen Home

construction or any other purpose without prior


written permission from Risen Home Design.
CALDWELL, ID 83605

copied whole or in part, disclosed, used for


NEW ADDITION EXISTING STRUCTURE

1603 E. BEECH ST.

ELEVATIONS NEW
FRONT VIEW - NEW BACK VIEW - NEW
1 1/4" = 1'-0" 2 1/4" = 1'-0"

REVISIONS

9/28/2023
10/4/2023
DATE
12 NEW ROOF
5 NEW ROOF 12
5

12
20 (N) 12
(N) 20 (N) (N)

NEW ADDITION

ISSUE FOR PRELIMINARY REVIEW


(E)

ISSUE FOR CONSTRUCTION


(N) NEW ADDITION

DESCRIPTION
EXISTING STRUCTURE

RIGHT VIEW - NEW LEFT VIEW - NEW


4

NO.
3 1/4" = 1'-0"

A
0
1/4" = 1'-0"

SHEET TITLE
ELEVATIONS
NEW

GENERAL CONDITIONS
DRAWINGS & SPECIFICATIONS RHD PROJECT NUMBER: RHD-990
IT IS THE INTENT OF THE DRAWINGS AND SPECIFICATIONS TO BE GUIDELINES
FOR CONSTRUCTION. THE CONTRACTOR IS RESPONSIBLE FOR DETERMINING DRAWN BY: RMC DATE: 9/28/2023
NOTE: RISEN HOME DESIGN PLANS DO NOT CARRY AN
ANY QUESTIONS AND MEANINGS IN THE WORKING DRAWINGS AND
ENGINEER'S AND/OR ARCHITECT'S STAMP(S) SOME CHECKED BY: MM DATE: 9/28/2023
SPECIFICATIONS AND THE CONTRACTOR SHALL NOTIFY THE DESIGNER IN
CONDITIONS MAY ARISE DURING DESIGN. AND/OR DRAWING NUMBER: REV:
WRITING OF ANY ERRORS, OMISSIONS, OR UNSUITABLE DETAILING WHICH MAY
CONSTRUCTION THAT MAY REQUIRE AN ARCHITECT'S AND/OR
CAUSE CONSTRUCTION PROBLEMS. THE DESIGNER'S LIABILITY REGARDING
A4.0 0
ENGINEER'S STAMP TO COMPLY WITH LOCAL BUILDING
ERRORS AND/OR OMMISSIONS WILL BE LIMITED TO THE CORRECTION OF THE
CODES. THE CONTRACTOR IS TO VERIFY THESE CONDITIONS
ORIGINAL DRAWINGS. CONSULTANT'S LITABILITY IS THE SAME.
AND SECURE REQUIRED STAMPS PRIOR TO CONSTRUCTION
Roof ROOF NOTES

390 E CORPORATE DRIVE STE 112


metal 1. TRUSS LAYOUT AND DESIGN TO BE SPECIFIED BY LOCAL TRUSS COMPANY. BUILDING

MERIDIAN, ID 83642
CONTRACTOR TO VERIFY ALL TRUSS LAYOUTS WITH TRUSS COMPANY BEFORE

#208-283-3775
ORDERING. ALL TRUSS PROBLEMS TO BE ADDRESSED BY CONTRACTOR AND TRUSS
7/16" OSB SHEATHING COMPANY.
2. ALL ROOF AND SOFFIT VENTS TO BE INSTALLED ACCORDING TO U.B.C. AND
APPLICABLE LOCAL CODES.
3. ALL TOTAL SPANS MAY VARY DEPENDING ON GIRDER TRUSS PLACEMENT. (IF
30 YR. COMP. ROOFING
NEEDED)
OVER #15 BLDG. FELT
4. ALL WINDOW HEADERS, GARAGE DOOR HEADER AND MICRO-LAM BEAMS UNDER
ROOF LOAD TO BE SPECIFIED BY LOCAL TRUSS COMPANY.

20:12
5. TRUSS COMPANY TO CONFIRM DESIGN ROOF SNOW LOAD SHOWN WITH COUNTY
REQUIREMENTS OF THIS HOUSE LOCATION.
TRUSS DESIGN & ENGINEERING
BY TRUSS COMPANY

R-38 CEILING INSULATION


DESIGN CRITERIA
SEE PLAN CALDWELL
LOCATION: (CITY)_______________ (COUNTY)______________
CANYON
• 30PSF
DESIGN ROOF SNOW LOAD: ______________
• 110MPH
DESIGN WIND SPEED:___________
• --
DESIGN WIND EXPOSURE TYPE:____________

5:12
• D1
DESIGN EARTH QUAKE ZONE:______________
• 24"
FROST DEPTH:____________
HEADER
1/2" SHEETROCK
P.E. BONUS ROOM TRUSSES
1" x 6" FASICA INSULATE VOID SPACE
+9'-1 1/8''

27'-6"
2 x 6 WOOD FILLER

BOXED SOFFET WITH


REQUIRED VENTING

5:12
TYPICAL HEADER @ DOOR & WINDOWS

metal

ALPAUGH REMODEL

Design. These drawings are NOT to be reproduced,


20:12

These Drawings contain confidential proprietary


information and are the property of Risen Home

construction or any other purpose without prior


SIDING (TYP.) TO MATCH EXISTING

written permission from Risen Home Design.


CALDWELL, ID 83605

copied whole or in part, disclosed, used for


7/16 WAFERBOARD SHEATHING

1603 E. BEECH ST.


2 x 6 STUDS @ 16" o.c. ROOF PLAN
1

ROOF PLAN
R-21 EXT. WALL INSULATION
1/4" = 1'-0"
1/2" SHEETROCK
NOTES:
2x6 P.T. SILL W/ 1/2'' Ø x 10'' ANCHOR BOLTS @ 48'' O.C. TYP. 3'' REBAR CLEAR COVER FOR ALL
W/ MIN. 7'' EMBEDMENT & NOT MORE THAN 12'' FROM CONCRETE IN CONTACT WITH SOIL U.N.O.
CORNERS & ENDS. (ALIGN EDGE OF SILL W/ FACE OF
MONO-POUR F.D.N.) UNLESS NOTED OTHER WISE
(2) #4 CONTINUOUS CONC. SLAB
@ TOP AND BOTTOM
MIN. 1-1/2'' CLEAR COVER
FOR THIS REBAR ONLY
4"
MIN.
6''

2% Grade REVISIONS
4"
6"

10/4/2023
DATE
°
.00
135
MIN. 2'-0"

3" FASTEN BRCING


#4 STIRRUP ≤10FT. FROM EDGE MATERIAL AS
@ 48'' O.C. OF BRACED WALL TO REQUIRED BY TABLE
START OF WALL ≤20 FT. BETWEEN R602.3-1
BRACE CLOSET EDGES OF WALL
BRACES
OPTIONAL @ HEATED AREAS:

0
CONTRACTOR TO VERIFY
R-10 PERIMETER INSULATION
AND MATCH TO EXISTING 1'-0" (CUT @ 45° AT TOP)
FOUNDATION AS REQ'D.

WALL DETAIL
2 1" = 1'-0"

BLOCK PANEL EDGES TO


MAINTAIN FASTENER
SPACING
1'-4" 1'-4" 1'-4" 1'-4" 1'-4" 1'-4" 1'-4" 1'-4" 1'-4"

DOUBLE TOP
PLATE

ISSUE FOR CONSTRUCTION


LOAD BEARING HEADER

DESCRIPTION
NON-LOAD BEARING HEADER

STUDS
1'-4" o.c.
TYPICAL WINDOW (TYP.)
ROUGH OPENING

NO.
0
DOOR
WINDOW SILL
(ROUGH OPENIGN) WSP DETAIL
FRAMING
4 3/4" = 1'-0" SHEET TITLE

CRIPPLE
STUD
TRIMMER STUD ROOF PLAN

GENERAL CONDITIONS

00
TYPICAL STUD BOTTOM PLATE
DRAWINGS & SPECIFICATIONS RHD PROJECT NUMBER: RHD-990
IT IS THE INTENT OF THE DRAWINGS AND SPECIFICATIONS TO BE GUIDELINES
FRAMING DETAIL NOTE: RISEN HOME DESIGN PLANS DO NOT CARRY AN
FOR CONSTRUCTION. THE CONTRACTOR IS RESPONSIBLE FOR DETERMINING DRAWN BY: RMC DATE: 10/3/2023
3 1/2" = 1'-0"
ENGINEER'S AND/OR ARCHITECT'S STAMP(S) SOME
ANY QUESTIONS AND MEANINGS IN THE WORKING DRAWINGS AND
SPECIFICATIONS AND THE CONTRACTOR SHALL NOTIFY THE DESIGNER IN
CHECKED BY: MM DATE: 10/3/2023
CONDITIONS MAY ARISE DURING DESIGN. AND/OR DRAWING NUMBER: REV:
WRITING OF ANY ERRORS, OMISSIONS, OR UNSUITABLE DETAILING WHICH MAY
CONSTRUCTION THAT MAY REQUIRE AN ARCHITECT'S AND/OR
CAUSE CONSTRUCTION PROBLEMS. THE DESIGNER'S LIABILITY REGARDING
A5.0 0
ENGINEER'S STAMP TO COMPLY WITH LOCAL BUILDING
ERRORS AND/OR OMMISSIONS WILL BE LIMITED TO THE CORRECTION OF THE
CODES. THE CONTRACTOR IS TO VERIFY THESE CONDITIONS
ORIGINAL DRAWINGS. CONSULTANT'S LITABILITY IS THE SAME.
AND SECURE REQUIRED STAMPS PRIOR TO CONSTRUCTION
conePAD

F 8or9
20O 25
50