Protection and Control IED Manager

PCM600
Installation Guide
Document ID: 1MRK505412-UEN
Issued: February 2023
Revision: A
Product version: 3.0

© 2023 Hitachi Energy. All rights reserved.


Copyright
This document and parts thereof must not be reproduced or copied without written permission from
Hitachi Energy, and the contents thereof must not be imparted to a third party, nor used for any
unauthorized purpose.

The software and hardware described in this document is furnished under a license and may be used
or disclosed only in accordance with the terms of such license.

Trademarks
and are registered trademarks of Hitachi Ltd. All other brand or product names
mentioned in this document may be trademarks or registered trademarks of their respective holders.

Warranty
Please inquire about the terms of warranty from your nearest Hitachi Energy representative.
Disclaimer
When the products and services provided by Hitachi Energy are designed to be connected to and to
communicate information and data via a network interface with Customer’s network or system
(Customer System), it is the sole responsibility of the Customer to provide and continuously ensure a
secure connection between the Customer’s System and Customer's network and any other network.
It is the sole responsibility of the Customer to establish and maintain any appropriate measures (e.g.,
the installation of firewalls, application of authentication measures, encryption of data, installation of
anti-virus programs, etc.) to protect the Customer’s System including its network and external
interfaces against any kind of security breaches, unauthorized access, interference, intrusion,
leakage and/or theft or losses of data or information. As necessary for the provision of work, the
Customer will permit Hitachi Energy’s employees, agents, consultants and/or subcontractors to
remotely access certain systems owned, controlled or operated by or on behalf of Customer.

Notwithstanding any other provision to the contrary and regardless whether the contract is terminated
or not, Hitachi Energy, its subcontractors, its and their affiliates and its and their employees are under
no circumstances liable for and the Customer shall defend and indemnify said parties from and
against any claim for damages and/or losses related to any security breaches, unauthorized access,
interference, intrusion, leakage and/or theft or loss of data or information resulting from Customer’s
failure to secure Customer’s System. In the event a Security Incident on Customer’s System results
in Hitachi Energy Information being disclosed such that notification is required to be made under any
applicable laws, or pursuant to a request or directive from a governmental authority, Customer will
coordinate with Hitachi Energy prior to the disclosure as mutually agreed, except as required by
applicable law.

The data, examples and diagrams in this manual are included solely for the concept or product
description and are not to be deemed as a statement of guaranteed properties. All persons
responsible for applying the equipment addressed in this manual must satisfy themselves that each
intended application is suitable and acceptable, including that any applicable safety or other
operational requirements are complied with. In particular, any risks in applications where a system
failure and/or product failure would create a risk for harm to property or persons (including but not
limited to personal injuries or death) shall be the sole responsibility of the person or entity applying
the equipment, and those so responsible are hereby requested to ensure that all measures are taken
to exclude or mitigate such risks.

This document has been carefully checked by Hitachi Energy, but deviations cannot be completely
ruled out. In case any errors are detected, the reader is kindly requested to notify the manufacturer.
Other than under explicit contractual commitments, in no event shall Hitachi Energy be responsible
or liable for any loss or damage resulting from the use of this manual or the application of the
equipment.
1MRK505412-UEN Rev. A Table of contents

Table of contents

Section 1 INSTALLATION GUIDE...................................................................................3


1.1 Related items........................................................................................................................ 3
1.2 Content on DVD/USB............................................................................................................3
1.3 System requirements............................................................................................................ 3
1.4 Hardware requirements, minimum/recommended:............................................................... 3
1.5 How to install PCM600 Ver. 3.0.............................................................................................3
1.6 Uninstalling............................................................................................................................4
1.7 Prerequisites for using PCM600 Ver. 3.0.............................................................................. 4
1.8 License.................................................................................................................................. 4
1.9 Previous versions of PCM600............................................................................................... 4
1.10 SQL Server access rights......................................................................................................4
1.11 Privileges needed by SQL Server Setup...............................................................................5
1.12 SQL Server 2019 Express.....................................................................................................5
1.13 SQL Server 2016...................................................................................................................5
1.14 Disk compression not supported........................................................................................... 5
1.15 SQL Server 2019 potential issue with UTF-8........................................................................ 6
1.16 Distributed setup................................................................................................................... 7
1.17 Unattended installation..........................................................................................................8
1.18 LON Support......................................................................................................................... 8
1.19 Document revisions...............................................................................................................8

Protection and Control IED Manager 1


Installation Guide
© 2023 Hitachi Energy. All rights reserved.
2
1MRK505412-UEN Rev. A Section 1
INSTALLATION GUIDE

Section 1 INSTALLATION GUIDE GUID-240AA3FF-E541-4A67-BAE1-CBC56DBA2E18 v2

1.1 Related items GUID-79E9785E-2A89-46A6-BC9D-F99C6CFA99B2 v2

PCM600 Ver. 3.0 Installation DVD/USB

PCM600 Ver. 3.0 Setup can be downloaded from https://softwarelibrary.hitachienergy.com/ or from


https://www.hitachienergy.com/in/en/offering/product-and-system/substation-automation-protection-
and-control/products/tools/pcm600.

1.2 Content on DVD/USB GUID-D88ECE8D-D240-40E5-A5FD-093366F5283D v2

• PCM600 Setup
• PCM600 Ver. 3.0 Readme file
• PCM600 Ver. 3.0 Installation Guide
• PCM600 Ver. 3.0 Product Guide
• PCM600 Ver. 3.0 Cyber Security Deployment Guide

PCM600 Setup includes the following software:

• Protection and Control IED Manager PCM600 Ver. 3.0


• Generic IEC 61850 IED Connectivity Package Ver. 3.0
• Wavewin Tool for Disturbance Analysis
• PCM600 Update Manager

1.3 System requirements GUID-ADCA0723-C027-449A-8B0E-6D4095EF3C14 v2

Operating system: Windows 10, Windows 11, Windows Server 2019, Windows Server 2022. Only
64-bit OS is supported.

Windows must be up-to-date to support the required runtimes and software components required by
PCM600. It is recommended to run Windows update before installing PCM600.

1.4 Hardware requirements, minimum/recommended: GUID-5457C262-FE02-477A-A993-7A861943C32A v2

• Physical RAM memory: 8 GB / 16 GB


• Free hard disk space: 4 GB / 8 GB

If working with large projects, it’s recommended to have 24 or 32 GB of physical RAM.

Windows compatible pointer (e.g. mouse)

1.5 How to install PCM600 Ver. 3.0 GUID-6DCB274E-CD47-42F7-BF27-936018739257 v2

a) DVD/USB Installation:
Insert the installation DVD/USB into the DVD/USB-drive. If the setup doesn’t start automatically,
execute PCM600_3.0.exe in the root folder of the installation DVD/USB.

b) Downloaded from Hitachi Energy Software Library:


After free registration, you will get an email with a link to download the executable installation.

Protection and Control IED Manager 3


Installation Guide
© 2023 Hitachi Energy. All rights reserved.
Section 1 1MRK505412-UEN Rev. A
INSTALLATION GUIDE

Start the installation and follow the instructions. After the installation starts, select the needed
software components and follow the instructions to complete the installation.

PCM600 requires Microsoft SQL Server 2019 Express edition. The correct SQL Server instance will
be installed automatically. If the correct SQL Server instance is already installed, PCM600 installation
will skip this step.

PCM600 installs .NET 4.8 if required. The .NET Framework might require a reboot.

Installation requires administrator rights. In all versions of Windows, it might be necessary to switch
off or configure antivirus software to not block the installation and operation of PCM600 (e.g. McAfee
Host Intrusion Prevention).

PCM600 is not supported on domain controllers.

1.6 Uninstalling GUID-C609AB02-CC17-4E73-BCC2-E6D0CDADE53F v2

PCM600 can be uninstalled from Apps and Features (Programs and Features). The name is
“HITACHI Protection and Control IED Manager PCM600”. Some included programs and runtimes
can only be uninstalled separately (they could be used by other programs). Examples are HITACHI
IED Connectivity Packages, Wavewin HITACHI and HITACHI PCMSERVER2019 SQL Instance.

1.7 Prerequisites for using PCM600 Ver. 3.0 GUID-5904719C-8E20-4210-9FEE-0384289BEBB3 v2

To operate with PCM600, there must be at least one IED Connectivity Package installed and
selected to be used with PCM600 Ver. 3.0.

1.8 License GUID-2A8F802E-5539-4600-8B97-30FE3F0F1922 v2

There is no license required for PCM600 Ver. 3.0.

1.9 Previous versions of PCM600 GUID-D8F8F88B-9C02-4FD6-84FE-346CA41384B6 v2

PCM600 3.0 can be installed in parallel with a previous version. If you only want to use PCM600 3.0,
you should uninstall previous versions of PCM600 before installing PCM600 3.0. It is recommended
to install PCM600 versions in ascending order.

When opening projects in PCM600 3.0 that have been created with previous versions of PCM600,
the projects will be converted automatically. After project conversion, the projects can't be opened
with older PCM600 versions anymore.

To migrate IED 670 configuration from PCM600 Ver. 1.5 to 3.0 (the whole PCM600 project including
all IEDs in the project), please refer to the document “1MRG002586 - Configuration Migration for 670
series in PCM600 User Manual", that can be found on the 670 series ConnPack DVD/USB.

1.10 SQL Server access rights GUID-3F4D27B5-C34B-44B3-B010-8230A8D63D48 v2

In PCM600 2.8 and later versions, data security has been enhanced, and for that reason every
Windows user using PCM600 must be given privileges to PCM600 project data. These privileges are
given by adding the Windows user to the new “HPCMSERVER Users” local user group.

4 Protection and Control IED Manager


Installation Guide
© 2023 Hitachi Energy. All rights reserved.
1MRK505412-UEN Rev. A Section 1
INSTALLATION GUIDE

During installation, the user logged in is automatically added to “HPCMSERVER Users” group. If
additional users are required, they must be added to the user group manually. This can be done by
using lusrmgr.msc (“Local Users and Groups (Local)”). This function provides a possibility to add
both local and network user accounts to HPCMSERVER Users Group.

In some cases, the user needs to logout and login again for all functionality to be available to
PCM600 due to the user group addition.

1.11 Privileges needed by SQL Server Setup GUID-64849616-59C5-4855-9879-1DD9FC126D64 v1

Microsoft SQL Server Setup needs following user rights during installation (see table below). These
user rights must be turned on for the user account running the setup during installation.

Local Policy Object User Right


Backup files and directories SeBackupPrivilege
Debug Programs SeDebugPrivilege
Manage auditing and security log SeSecurityPrivilege

If these user rights are disabled by your system administrator, please contact your system
administrator to enable the user rights during installation. A separate user account with these rights
enabled can also be used during installation. If needed, these user rights can be turned off again
after installation.

1.12 SQL Server 2019 Express GUID-B2CEA57B-7390-4A5A-A304-323812607A46 v2

PCM600 3.0 uses Microsoft SQL Server 2019 Express. This instance is separate from and doesn’t
interfere with the SQL instance in older versions of PCM600 that use older versions of SQL Server.
The instances can co-exist. It is however strongly recommended to install older SQL Server versions
before newer ones.

PCM600 version SQL Server version


2.1 - 2.7 2008 Express
2.8 - 2.10 2014 Express
2.11 2019 Express
3.0 2019 Express

1.13 SQL Server 2016 GUID-1572FE1B-25CF-4E9A-BD7F-FA395D0E79F2 v2

PCM600 is not compatible with SQL Server 2016. SQL instances should not be upgraded to a not
supported SQL version.

1.14 Disk compression not supported GUID-C9A579B3-6988-4B33-8BDE-EE3511B36E41 v2

SQL server doesn’t support having its data on a compressed disk. PCM600 SQL data directories are
by default located in a subdirectory of C:\ProgramData\HITACHI, which is determined by an
environment variable HITACHIPCMDATADIR set by the PCM600 installation.

Protection and Control IED Manager 5


Installation Guide
© 2023 Hitachi Energy. All rights reserved.
Section 1 1MRK505412-UEN Rev. A
INSTALLATION GUIDE

1.15 SQL Server 2019 potential issue with UTF-8 GUID-91B1441C-EE5F-4A60-B24A-8DB3841A8150 v2

In Windows 10 and Windows Server 2019 it is advisable to not enable ‘Beta: Use Unicode UTF-8 for
worldwide language support’ in ‘Region’ setting.

If this setting is enabled by your system administrator, please contact system administrator to disable
this setting for a successful installation of PCM600 3.0.

This UTF-8 setting is available in [Region] -> [Administrative] tab -> [Region setting] page. See
picture below.

GUID-2A50FB93-EA64-414A-9F22-9C982E25C94C V2 EN-US

6 Protection and Control IED Manager


Installation Guide
© 2023 Hitachi Energy. All rights reserved.
1MRK505412-UEN Rev. A Section 1
INSTALLATION GUIDE

GUID-C9E08DFD-D006-4B27-835D-3D3638D94283 V2 EN-US

If this setting is enabled, installation of SQL Server Service Packs might fail.

Before starting the PCM600 installation, ensure that any SQL Server Windows updates
have been installed. If SQL Server updates are being installed, wait until they are
installed, reboot the computer if required, and then start PCM600 installation.

Please reboot the computer after every installation or uninstallation of SQL Server.

1.16 Distributed setup GUID-37804B05-EB6B-494F-BA08-8181B73B6E1D v2

PCM600 3.0 supports having SQL Server and PCM600 installed on different machines. It allows
using PCM600 projects from multiple PCs, but multiple machines can’t open same project at same
time. Using distributed setup has effect on performance because SQL Server is accessed over the
network.

To make a distributed installation select “Options” in PCM600 installation wizard. First PCM600
should be installed on server machine using option “Install only SQL Server”.

After server installation you need to share folder defined by “HITACHIPCMDATADIR” system
environment variable. If you have installed PCM600 without specifying the path manually from
command line, it is “[drive]:\ProgramData\HITACHI\HPCMDatabases\" by default.

Share this folder with full privileges for Windows user group “HPCMSERVER Users” on server
machine. Use the name “HPCMDatabases” for the shared folder. Each Windows user using PCM600
must be added to “HPCMSERVER Users” group, refer to PCM600 Cyber Security Deployment
Guideline.

The name of the distributed PCM600 server should be according to the below guidelines:

• The first character in the instance name must be a letter or an underscore.


• Subsequent characters can be alphabets, decimals, dollar signs ($), or underscore (_).
• Embedded spaces or other special characters are not allowed in instance names.

The default port used by the distributed PCM600 is 1436. If it is occupied, then select the
next available port, for example, 1437.

Protection and Control IED Manager 7


Installation Guide
© 2023 Hitachi Energy. All rights reserved.
Section 1 1MRK505412-UEN Rev. A
INSTALLATION GUIDE

Then PCM600 can be installed on client machine. Select “Options” and “Install only PCM600” in the
PCM600 installer. Give the IP address or computer name of the server machine. It is assumed that
the shared folder on server is named “HPCMDatabases”.

If shared folder name is something else than “HPCMDatabases”, you need to edit the System
Environment variable HITACHIPCMDATADIR on the client and set the correct path to the server
folder. Note that the path must be given as UNC path ("e.g.\\server\HPCMDatabases\") when using
distributed setup.

In order to use the Scheduler service on PCM600, the logon account for the service must be same
as the intended Windows account for running PCM600. The service logon account can be configured
in Services.msc, HITACHIPCMSchedulerService_v30 on the Log On tab.

To avoid time synchronization related problems, please make sure that all PCM600 machines have
same system time.

1.17 Unattended installation GUID-740F907F-FF73-434A-8DBF-7DF9ED62561B v2

PCM600 3.0 can be installed silently from command line by appending the /quiet parameter to the
installation package. If installation is done centrally, users of the PCM600 application must be added
to the local group “HPCMSERVER Users” after installation.

1.18 LON Support GUID-C289C42C-74A7-410E-B8AD-E1090F6B9C19 v2

PCM600 2.10 and earlier versions use PCLTA cards from Echelon (now Dialog Semiconductor) for
communicating to LON IEDs via compatible drivers. However, there are no 64-bit compatible PCLTA
drivers available. PCM600 3.0 supports only 64-bit operating systems due to Microsoft SQL Server
2019 requirements.

Due to the lack of compatible drivers PCM600 3.0 cannot support existing LON IEDs using PCLTA
cards. However, Customers using PCM600 2.10 or older product versions can continue to use LON
IEDs if the PCM600 product is being used from a supported 32-bit Windows OS with compatible
PCLTA drivers.

1.19 Document revisions GUID-2B242226-9C94-4B57-AA01-AA92B671353D v1

Document revision Date Product version History


A 2023-02 3.0 First Release

8 Protection and Control IED Manager


Installation Guide
© 2023 Hitachi Energy. All rights reserved.
9
Hitachi Energy Sweden AB
Grid Automation Products
SE-721 59 Västerås, Sweden
Phone +46 (0) 10 738 00 00

https://hitachienergy.com/protection-control Scan this QR code to visit our website


1MRK505412-UEN

© 2023 Hitachi Energy.


All rights reserved.