Airscience Technology International Ltd.

MF - Multiflex Range

Model: AS430 - MF20, MF40, MF60, MF80

lnstruction Manual

www.airsteril.co.uk

DO NOT LOOK DIRECTLY AT THE LAMP WHEN IN OPERATION


UV Radiation is very harmful to eyes and skin. Strictly observe the instructions
Getting Started AS340/ MF Range Air Purifier
(1) The unit is ready for use when the power cable is connected to the socket ( A Please read these instructions carefully before operating this unit. This will
as shown ) and the switch ( B as shown ) is turned on enable you to obtain optimum performance and a longer service life from your
(2) The unit should be placed in a ventilated area for the first day of using. air sterilizer unit.
Some initial odour caused by the electric components may be released.
After one or two days, no odour of this type will be evident Important Safety Instructions
(3) This air sterilizer unit is designed to be wall or ceiling mounted but can also
be placed on flat stable surface. For use on a flat surface, four rubber
bumpers can be fixed to the nut plates. Mounting brackets provided replace Electrical Hazard
the rubber feet for wall or ceiling mounting, these can be adjusted along the (1) Do not use the unit outdoor where exposed to rain or water.
base plate as required. (2) Only connect the unit to a single phase socket with a main voltage as
(4) The ideal locations for wall mount is approximately 2 meter from ground specified on the rating plate
level (3) Do not handle plug or the unit with wet hands
(5) Do not install the unit in a position that inlet or outlet will be (4) Do not operate the unit near sources of water-for example, bathtub, wash
blocked/impeded. This will affect efficiency. bowl, kitchen sink, laundry tub or swimming pool.
(6) Always keep the unit operating 24hrs a day, 7 days a week If the unit comes in contact with liquid, remove its plug from the outlet
(7) For the best long term results, always keep the unit in the same area immediately.
(8) Keep away from water, especially if unit is installed in a higher moisture Warnings
environment
Cleaning (1 ) Do not allow foreign objects to enter the air outlet or inlet openings of the
unit, this may cause damage to unit or electric shock
(1) Disconnect plug/power cord before commencing any cleaning (2) To reduce the risk of electric shock this unit is provide with a grounding
(2) There is little cleaning required. Vacuum cleaner may be needed to clean the type plug and cable. Do not operate on a non-grounded outlet or connect to
dust or debris accumulated on inlet and outlet openings. a spur without a grounding connection
(3) Do not use wet cloth to clean inlet and outlet openings of the unit. (3) Keep the unit and its cord away from heated surfaces and never operate the
(4) Please be careful when cleaning is in progress. unit if it has a damaged cord
(5) Do not touch the quartz part of the UV lamp tube and the photo-catalytic (4) Do not block air outlet and/or inlet openings of the unit
plates ( F as shown ) by any means. These plates have the feature of self (5) Do not use the unit where combustible gases or vapours are present
cleaning. (6) Keep away from water splashes if the unit is installed in washroom / toilet /
(6) Use a dry cloth to clean any dirt of the lamp surface ( G as shown ) kitchen
(7) Keep the unit out of reach of children
Lamp Replacement (8) Never look directly into the burning UV lamp tube. Doing so can cause
eyes and skin dryness and irritation
After approximately one year or over 8,000 hrs of continuous burning, the (9) Reflected blue light showing through the outlet, inlet or edge of unit
UV-C lamp will lose 20 to 30% of its UV power and need to be replaced for openings and front window is safe to look at
intended performance. Please disconnect the power before opening the cover (10) Never operate unit if there is an unfamiliar sound or vibration
(D as shown) for lamp replacement. Avoid touching photo-catalytic base (11) Disconnect the plug/power cord if the unit will not be used for a long
plates. period of time

DO NOT LOOK DIRECTLY AT THE LAMP WHEN IN OPERATION DO NOT LOOK DIRECTLY AT THE LAMP WHEN IN OPERATION
UV Radiation is very harmful to eyes and skin. Strictly observe the instructions UV Radiation is very harmful to eyes and skin. Strictly observe the instructions

4 1
Installation Method Model: AS430 - MF20, MF40, MF60, MF80

Adjustable width
Horizontal wall mounting: A Power cable socket
(Ready for use when connected to the
Four adjustable nut plates are cable provided)
installed into the grooves on the B On/Off switch
backside of the unit. Brackets
C Air inlet vent C
can be fixed to these nut plates
by screws. D Cover
E Air outlet vent
Nut plate Bracket F Catalyst plates B
G UV lamp tube A D
H Lamp holding plate finger screw
Vertical wall mounting:
Use two brackets fixed to the
nut plates at the end of the unit
so it hangs vertically. G
Air flows out the opposite end
to the power cable connection,
air flow should be targeted
towards the ceiling. F

Ceiling mounting:
All four brackets can be fitted
to the nut plates for secure
installation on the ceiling.

E H

DO NOT LOOK DIRECTLY AT THE LAMP WHEN IN OPERATION DO NOT LOOK DIRECTLY AT THE LAMP WHEN IN OPERATION
UV Radiation is very harmful to eyes and skin. Strictly observe the instructions UV Radiation is very harmful to eyes and skin. Strictly observe the instructions

2 3
Technical Specifications

Air purifying technology Nano-titanium dioxide photocatalytic


oxidation + Ultra-violet light UV-C
UV-C lamp tube 18W PLL composite tube
UV-C intensity inside chamber 15,000 uw /sq.cm
UV-C lamp tube life > 8,000 hr
Air residence time inside chamber > 0.5 second

Number of photo-catalyst plates 3 pcs

Dimensions 430(L) x 130(W) x 100(H)mm

Unit weight 2.05 kgs

Noise level @1m <39dB


Voltage 220-230V
Frequency 50/60Hz

Air flow rate 20 cu.m/hr

Power consumption 33W

Suggest covering area Average 20-80 sqm


Wall/ ceiling mount 1.8 meter from
Installation
ground level (can also be free standing)
Housing material All aluminum alloy extrusion structure
Detachable power cord 1.8 m
Cover housing color Silver

Front/ rear unit color Black


9.5mg 38mg 50mg 70mg
UV lamp (photoplasma)
MF20 MF40 MF60 MF80

DO NOT LOOK DIRECTLY AT THE LAMP WHEN IN OPERATION


UV Radiation is very harmful to eyes and skin. Strictly observe the instructions