Professional Documents
Culture Documents
Rooftop / Towertop
powered by
Features
Connection for six individual -48V DC circuits (no overvoltage protection)
Fiber connections for up to 18 fiber pair
Simplifies inter-connectivity and cable management for DC conductors
Enclosure is rated for -40° C to +80° C
Dome design is lightweight and aerodynamic
Benefits
Enables simplified DC power and fiber optic cable management
Design provides maximum flexibility for installation on top of towers or rooftops
NEMA 4X enclosure allows for indoor or outdoor installation
www.raycap.com
SPECIFICATIONS Connection Solutions for Rooftop or Towertop
FC18-PC6-8F
powered by Fiber Optic/DC Power Cable Connection Solution
Mechanical
Model Number FC18-PC6-8F
CEQ / ANT Number CEQ.11167
Connection Terminal (Alarm) Method Form C Hardwired, #22 to #12 AWG [0.34 to 4 mm2]
Compression lug, #14-#2 AWG (2.5mm2 - 35 mm2) Copper,
DC Connection Method
#12-#2 AWG (4 mm2 - 35 mm2) Aluminum
Fiber Connection Method LC-LC Single Mode
Environmental Ingress Protection (IP) Rating IP 68
Operating Temperature (°C) -40º C to +100º C
Storage Temperature (°C) -70º C to +80º C
Cold Temperature Cycling IEC 61300-2-22 -30º C to +60º C 200 hrs @5 PSI
Resistance to Aggressive Materials CEI IEC 61073-2 Including Acids and Bases
UV Protection ISO 4892-2 Method A Xenon-Arc 2160 hrs
Enclosure Type Outdoor NEMA 4X
Enclosure Dimensions (L x W x H) 18.17" × 20.06" × 6.37" [461.39 × 509.52 × 161.71 mm]
Weight* System: 12.7 lbs [5.67 kg] Mount: 13.9 lbs [6.30 kg] Total: 26.6 lbs [12.07 kg]
Combined Wind Loading Sustained 150 mph Sustained: 105.7 lbs [470 N]
Gust 195 mph Gust: 213.6 lbs [950 N]
Product Diagram
[mm]
inches
260 260
10.24 10.24
31.41
31.41
798
798
13.50
13.50
343
343
464 464
18.28 18.28
www.raycap.com
G02-00-102 150115