Pre-sales package
Monobloc Domestic Hot Water Heat Pump
July 2017
Content
Section 1 - introduction
Background of development
Sales territories
There is a growing demand for Domestic Hot Water Heat Pumps (DHW HP) in the new
build market, as well as in the replacement market to replace electric heated cylinders.
A major part of the Domestic Hot Water Heat Pump sales come from Monobloc.
DOMESTIC HOT WATER
Split HEAT PUMP
MARKET
MONOBLOC
MONOBLOC
> 80% Monobloc
Main volume: 260 L
Market size: 17K
WATER OUTLET
HEAT PUMP
Mg ANODE 1
RECIRCULATION
CONTROL PANEL ELECTRICAL
HEATER
SOLAR SERP. IN
ENCLOSURE IN CONDENSED
EMBOSSED ABS WATER
Mg ANODE 2
SOLAR SERP. OUT
PROBE
IMMERSION
FITTING WATER INLET
AMBIENT AIR
RECIRCULATION
FAN
ROTARY
COMPRESSOR EVAPORATOR
EXPANSION
VALVE
UPPER PROBE
LOWER PROBE
TANK
WRAP
CONDENSER
53 dB(A)
Sound level
Thanks to its compact sizes, it can easily pass from the doorway.
650 mm
Height:
200 L 1710 mm
600 mm 260 L 2000 mm
15 Monobloc Domestic Hot Water Heat Pump - Internal use only
Enhanced comfort: 3 operating modes
AUTOMATIC mode
AUTO
( heat pump + heating element as support )
• Set-point parameter: SP2 (default = 55⁰C)
• In AUTO mode the heating element works to guarantee the min.
temperature of 45⁰C (SP3) and it switches-off when the temperature
of upper probe reaches the value of SP2 set point
• HP works until the value of lower probe reaches SP2 set point
ECO
( heat pump only )
• Set-point parameter: SP1 (default = 55⁰C)
• HP stops when lower probe detects a temperature of 55⁰C
• HP starts when the temperature detected by the lower probe is
lower than set point temperature (SP1) minus hysteresis value (r0:
7⁰C default)
BOOST
( heat pump + heating element for fast heating )
• At the end of the heating process, the function is automatically
disabled and the equipment is automatically restored to the AUTO or
ECO mode (depending on which was previously set by the user)
• The cycle ends when the upper probe reaches the set-point value (SP1
ECO mode or SP2 AUTO mode)
TOP SIDE
CONNECTION CONNECTION
ST PV
E I
DIGITAL INPUT 2
Photovoltaic Configuration (wires: 32 white / 31 green)
The PV system works only to increase the water temperature from SP1 to SP6.
If it is required to switch off the HP when the PV system does not
produce energy, timeslots should be set.
The heat pump is provided with an additional 4-core cable that has already been
linked to circuit board of the user interface.
Cable for solar
connection is included
30 31 31 32
30 31 31 32
30 31 31 32
In the summer the heat pump can be outfitted In the winter the heat pump can be outfitted
to extract the inside hot air and deliver cold to extract the inside air and deliver the cold
dehumidified air indoors for cooling down dehumidified air to the outdoor
living spaces. environment.
Hot indoor
air
Dehumidified
cold air
Hot indoor
air
Water
70 ⁰C
ELECTRICAL HEATER
62 ⁰C
OUT OF RANGE
56 ⁰C
HEAT PUMP
10 ⁰C Air
-7 ⁰C 20 ⁰C 38 ⁰C
200
EK HH 2 E 260
(P) A A V3
Model change
Model change
(*) Temperature of incoming air supply 15⁰C, temperature of boiler storage environment 20⁰C, water heated from 10⁰C to 55⁰C (according to UNI EN 16147-2011)
27 (**) Temperature of incoming air supply 7⁰C, temperature of boiler storage environment 20⁰C, water heated from 10⁰C to 55⁰C (according to UNI EN 16147-2011)
Installation manual
Language Code EKHH2E200AAV3 EKHH2E260AAV3 EKHH2E260PAAV3
English EN STD
German DE STD
French FR STD
Dutch NL STD
Printed
Spanish ES STD
Italian IT STD
Portuguese PT STD
Turkish TR STD
Swedish SV STD
Polish PL STD
Greek EL DOD
Danish DA DOD
Norwegian NO DOD
Available digitally
Finnish FI DOD
Czech CS DOD
Croatian HR DOD
Hungarian HU DOD
Romanian RO DOD
Slovenian SL DOD
Bulgarian BG DOD
Slovak SK DOD
Serbian SR DOD
Albanian SQ DOD
28 Monobloc Domestic Hot Water Heat Pump - Internal use only
Service (intervention) videos
200 L
Intervention
260 L
Controller replacement
Fan replacement
Anode replacement