12a. Explain with neat block diagram the operation of static relay and mention the advantages and
disadvantages of static relays. [CO4, L3, PI: 1.3.1] (13 Marks)
OR
12b. Draw and explain the block diagram of static time overcurrent relay along with its time-current
characteristics. [CO4, L3, PI: 1.3.1] (13 Marks)
13a. Draw and explain the block diagram of a numerical relay and also state the advantages and
limitations of a numerical relay and flowchart. [CO4, L2, PI: 1.3.1] (13 Marks)
OR
13b. Discuss the block diagram of Numerical over current protection with a neat sketch along with
its flow chart. [CO4, L3, PI: 1.3.1] (13 Marks)
14a. Explain the terms restriking voltage, recovery voltage and RRRV. Derive expressions for
restriking voltage and RRRV. [CO5, L2, PI: 1.3.1] (13 Marks)
OR
14b. Explain the phenomenon of current chopping in circuit breaker and list the methods to reduce
the same. [CO5, L2, PI: 1.3.1] (13 Marks)
15a.Draw the schematic of a HVDC circuit breaker and explain its functioning.
[CO5, L2, PI: 1.3.1] (13 Marks)
OR
15b. Explain with neat sketch the construction, operating principle of minimum oil Circuit Breaker
with its merits and demerits [CO5, L2, PI: 1.3.1] (13 Marks)
16a. (i) Enumerate the synthesis of various relays using static comparators
[CO4, L3, PI: 1.3.1] (8 Marks)
(ii) In a short circuit test on a 3 pole, 132 kV circuit breaker, the following observations are
made. Power factor for fault =0.4,recovery voltage 0.9 times full line value, the breaking current
symmetrical, frequency of oscillation of restriking voltage 16 kHZ. Assume neutral is grounded
and fault is not grounded. Determine average RRRV. [CO5, L3, PI: 2.1.3] (7 Marks)
OR
16b. (i). Explain the concept of duality in static comparators.
[CO4, L3, PI: 1.3.1] (7 Marks)
(ii) A Circuit breaker is connected with 100MVA transformer at 220 kv. The magnetizing
current of a transformer is 5% of the full load current. Determine the maximum voltage which may
appear across the gap of the breaker when the magnetizing current is interrupted at 53% of its peak
value. The stray capacitance is 2500 μF. The inductance is 30H [CO5, L3, PI: 2.1.3] (8 Marks)
After completion of the course, it is expected that the students will able to
CO3: Interpret the suitable protection system for the apparatus protection.
CO4: Evaluate the performance of the Static relays and Numerical protection.
*****
12a. How static overcurrent relays are different for electromechanical relays? Explain how the
operation of instantaneous overcurrent relay is achieved using electronic circuits.
[CO4, L2, PI: 1.3.1] (13 Marks)
OR
12b. Explain the static differential protection scheme and illustrate its application power transformer
with necessary circuit diagrams. [CO4, L3, PI: 1.3.1] (13 Marks)
13a. Discuss the operation of numerical differential protection scheme used for the transformers.
[CO4, L2, PI: 1.3.1] (13 Marks)
OR
13b. Explain the operation of a numerical distance protection scheme used for the transmission line
protection. [CO4, L3, PI: 1.3.1] (13 Marks)
14a. Derive the expression to find the critical values of resistance to be connected across the circuit
15a. With neat figure, explain the construction and working of SF 6 circuit breaker. What are
advantages, applications and disadvantages of SF6 breaker? [CO5, L3, PI: 1.3.1] (13 Marks)
OR
15b. Explain the construction, working, advantages, application and the disadvantages of Vacuum
circuit breakers. [CO5, L3, PI: 1.3.1] (13 Marks)
After completion of the course, it is expected that the students will able to
CO3: Interpret the suitable protection system for the apparatus protection.
CO4: Evaluate the performance of the Static relays and Numerical protection.