SRI VENKATESWARAA COLLEGE OF TECHNOLOGY


DEPARTMENT OF EEE
SET-2 MODEL EXAM COIPES 07
EE 6702 – PROTECTION AND SWITCHGEAR
Year / SEM: IV/VII Date: 09-10-2019
Time: 3 Hours Maximum: 100 Marks

PART – A (ANSWER ALL QUESTIONS) (10X2=20)

1. Write down the importance of symmetrical components for fault current calculation?
2. What is primary protection and back up protection?
3. What is primary protection and back up protection?
4. What are the main types of stator winding faults?
5. List the type of bus - bar protection.
6. List the type of bus - bar protection.
7. What are the applications of static relay?
8. What are the differences between the conventional relay and numerical relays.
9. What are the differences between AC circuit breaking and DC circuit breaking?
10. Give the two methods of arc interruption
PART – B (5*13=65)
11. A) Explain the overlapping of protective zones with neat sketch. Describe the fundamental
requirements of protective relaying.
(or)
B) (i) A 132kV, a phase, 50 cycles, overhead line, 50km long has a capacitance to earth line
of 0.0157 µ F/km. Determine the inductance and KVA rating of the arc suppression coil (6)
(ii) Discuss the qualities of protective relaying. (7)
12. A) Briefly explain about negative sequence relay in detail.
(or)
B) (i) Universal torque equation (ii) Directional Power relay
13. A) Describe the types of protective schemes employed for the protection of stator winding
of alternator.
(or)

SVCT /MODEL EXAM/ Subject Code: EE 6702


Page 1 of 2
B) Discuss in detail about the schemes normally used for protection of a power transformer
against the transformer inrush current.
14. A) Define static relay? What are the merits and demerits of static relays over
electromagnetic relays also mention its applications? Explain about block diagram of
static relays.
(or)
B) Illustrate and Explain with neat Block diagram of Numerical relays.
15. A) Explain in detail about (i)RRRV (ii)Resistance switching
(or)
B) explain about arc control methods in bulk oil circuit breaker with neat diagram.
PART – C (1*15=15)
16.a) (I) A 50 Hz, 11 KV, 3 phase alternator with earthed neutral has a reactance of 5 ohms per
phase and is connected to bus bar through a CB. The distributed capacitance up to CB between
phase and neutral is 0.01µf. determine (i)peak re striking voltage across the contacts of the
breaker.(ii)frequency of oscillation. (iii) the average rate of rise of re striking voltage up to the
first peak.
(15)
(OR)
b) (i)Solve the RRRV of 132 kV circuit breaker with neutral earthed circuit breaker data as:
broken current is symmetrical, restriking voltage has frequency of 20 kHz, and power factor
is 0.15. Assume fault is also earthed
(7)
(ii) Give the reason of using SF6 circuit breaker. (8)