CZ-TAW1B [E64]

WH-SDC0309K3E5
T
H2
PAW-A2W-TSOD [E36]
CZ-NS5P
H12 [E39]

[E62]

Refrigerant Connection [E61]


Factory Charge (kg) 1.3
Piping Distance (m) 3 - 50
Add. Charge >10 m (m) 25
Gas Pipe Diameter (mm(in)) 5/8
Liquid Pipe Diameter (mm(in)) 1/4
H4[E33]

H9 [E53(E29)/E41]
RT1
H7 PAW-A2W-TSHC [E45]
H14 [E58]
H11

WH-UDZ09KE5
H1 PAW-A2W-TSHC [E44]
H10

PAW-A2W-TSBU [E42]
H9 [E54/E40]
[E63]
RT2

H3 PAW-BTANK100L H14 [E59]


H6 H11
H5

Hydraulic Connection
Type BSPP (male)
Inlet & Outlet Size (mm(in)) 31.75 (1-1/4)
Nom. Flow Rate (l/m) 25.8

2024-03-29,08:32:31 WH-SDC0309K3E5 + WH-UDZ09KE5 Tóth Krisztián Darnózseli Darnózseli


A: HO-SN-MV.dxf, B: DEVBUFFER-SOLHEATNO-MONOVALENT.dxf, C: BUFFERYES-DIRECT-DIRECT-VALVENO.dxf, IDU: bibloc-k, ODU: outdoor-i
E26

L N C H N O C N O C E39

E54
AC 230 V
E34 (Room thermo 2)
ON/OFF
E65 (external control)

CN-CNT2
E33
RC
(Remote controller) E50
(external compr.sw)

E36
PAW-A2W-TSOD E49
(outdoor air sensor) (heat/cool switch)

E42
PAW-A2W-TSBU
(buffer tank sensor) E57
(error signal) CZ-NS5P

VCC BIT2 BIT1


E48
SG READY
E58 (SG signal)
AC 230 V
(water pump zone 1)

E59 E64
AC 230 V CN-CNT
(water pump zone 2)

PAW-A2W-TSHC

PAW-A2W-TSHC
E29

PAW-A2W-TSRT

PAW-A2W-TSRT

(water sensor zone 2)

(water sensor zone 1)


(room temp. zone 2)

(room temp. zone 1)


AC 230 V

(demand signal)
(Room thermo 1)

0-10 V
E41
E40

E44

E46
E45
H C N L

E60
E61 E62
DC DC
GND 10V

E63
L N L1 N1

1 2 3
connection type
required
optional
POWER SUPPLY 1 POWER SUPPLY 2

2024-03-29,08:32:31 WH-SDC0309K3E5 + WH-UDZ09KE5 Tóth Krisztián Darnózseli Darnózseli


E33,E36,E39,E40,E41,E42,E44,E45,E53,E54,E58,E59,E61,E62,E63,E64
Rendszer alkatrészlistája
Panasonic Components
REF CODE NR DESCRIPTION
H1 WH-UDZ09KE5 1 Kültéri egység [09, E5]
H2 WH-SDC0309K3E5 1 Split beltéri egység (4) [0309, E5]
H9 PAW-A2W-TSRT 2 Szobai érzékelő (ha szükséges) (1)
H10 PAW-BTANK100L 1 Puffertartály
Választható nyomtatott áramköri lap a K és L generációs
H12 CZ-NS5P 1
hőszivattyúkhoz
E36 PAW-A2W-TSOD 1 Külső hőmérséklet érzékelő (választható)
--- PAW-GRDBSE20 1 Talp a kültéri egységhez (választható)
--- CZ-NE2P (single fan models) / CZ-NE3P (twin fan models) 1 Vezérelt alaplemez fűtés (választható)
E42 PAW-A2W-TSBU 1 Puffertartály érzékelő
Hőszivattyú vezeték nélküli / vezetékes vezérlése interneten
E64 CZ-TAW1B 1
keresztül (választható)
E44/E45 PAW-A2W-TSHC 2 Vízköri szenzor (kötelező)

Third Party Components


REF CODE NR DESCRIPTION
Franciaországban és Belgiumban kötelező, más országokban
H5 Visszaáramlásgátló 1
választható
H6 Tágulási tartály 1 ha szükséges
H9 Szoba termosztát 2 ha szükséges (1)
H14 Vízszivattyú 2 A rendszer követelményeinek megfelelően kell meghatározni

Footnotes

A szoba termosztátokat vagy szobai érzékelőket a kijelölt körök


1
vezérlésének megfelelően kell kiválasztani.
Normál működés esetén a víznyomás értéke 0,5 bar és 3 bar között
4
kell, hogy legyen.
LEGEND – Refrigerant Split System
Legend for the hydraulic part Legend for the electric part
Refrigerant Split heat pump outdoor unit (provide outdoor unit Main board PCB: the maximum cable length for sensor inputs is 30
H1
drain) E26 meters and the maximum cable length for outputs and other inputs
Split heat pump indoor unit: the magnetic filter and the flow meter is 50 meters.
H2
are included in all K generation heat pumps. E27 2 way valve: open for heating (O+N) and close for cooling (C+N)
The refrigerant inside the HP is R32. For split units, the refrigerant 3 way valve: open for DHW (O+N) and close for heating/cooling
pipes’ maximum length is 50 m with 30 m maximum of height E28
system (C+N)
difference between indoor and outdoor unit. The 3 kW LT unit has Optional thermostat 1: every circuit can be controlled with one
H3
a 25 m maximum length and 20 maximum height difference. For all optional thermostat (E29 for one zone and E29 and E54 for 2
size HPs, the minimum distance between indoor and outdoor unit is E29
zones), with one room sensor (E37 for one zone or E40 and E41
3m. The R32 precharge will cater for 10 m. for 2 zones) or with the remote controller (E 33, 1 or 2 circuits).
Remote controller of the Heat pump. Dual remote controls may be E30 Booster heater
H4
used (optional). E31 Extra pump control
H5 System charge and backflow device
E32 ON/OFF boiler or deice output (dry contact)
Expansion vessel: every HP has a 10 litre expansion vessel that
Remote Controller: the K generation heat pump remote controller
will cater for 200 litres at 55°C in the fully open heat pump circuit.
H6 E33 can be used as a room thermostat for two circuits. The cables
Any variation, greater than the specification stated, will require a
maximum length is 50 meters.
secondary expansion vessel added to the system.
E34 External ON/OFF (dry contact)
Electrical connections: to be defined when the hydraulic scheme
H7 E35 DHW tank sensor
and the system control logic have been selected.
H8 Automatic bypass valve E36 Outdoor air sensor (optional)
Optional thermostat: every circuit can be controlled with one E37 Zone 1 room sensor (see point E29)
H9 optional thermostat, with one room sensor or with the remote OLP booster heater: on the OLP contact must be put a jumper if
controller (CZ-RTW1 additional controller for additional circuit). E38 external booster heater is used and controlled by Panasonic heat
Buffer tank / Volumiser: in the open primary circuit (when all pumps.
heating – cooling circuits are closed) it is recommended a minimum Optional PCB: the maximum cable length for sensor inputs is 30
H10 water volume of at least 30 litres up to and including 9 kW units meters and the maximum cable length for outputs and other inputs
and 50 litres for 12 (kW stated is nominal heating capacity of the E39 is 50 meters. If the optional PCB (CZ-NS5P) is installed, the room
heat pump A7/W35). sensor 1 and the extra pump control contacts of the main PCB are
Heating/cooling circuit: If the HP is connected directly to the disabled
system, the minimum water flow rate must be guaranteed. Provide E40 Zone 2 room sensor (see point E29)
an automatic bypass valve (recommended 1'' diameter) or a 3-way E41 Zone 1 room sensor (see point E29)
H11 diverting valve on hydronic indoor units (fan-coil, duct unit etc.) or a E42 Buffer tank sensor
thermostat must be removed to ensure sufficient flow. If you have E43 Pool water sensor
floor heating provide a safety thermostat (for heating mode) and a
E44 Water sensor zone 2 (see point E29)
dew-point sensor (for cooling mode).
E45 Water sensor zone 1 (see point E29)
H12 Optional PCB - CZ-NS5P - needed for this scheme
E46 Demand signal (0-10 V)
H13 Mix valve with 3 points control
Secondary water pump: they must be chosen according to the E47 Solar sensor
H14 Smart Grid signal: the 2 contacts can increase the set-point for
system hydraulic performance.
H15 Boiler DHW and heating or cooling if there is energy production from the
E48 PV panels. The 2 input contact can be also used to control a
H16 Solar panels bivalent system with boiler and heat pump using an external
H17 Solar pump control. The 2 options exclude one another.
H18 Pool pump E49 Heat / cool switch
H19 Heat exchanger for the swimming pool (to be sized) E50 External compressor switch
H20 Swimming pool E51 Mixing valve zone 2
H21 Expansion vessel (cold water) E52 Mixing valve zone 1
H22 Sanitary equipment E53 Optional thermostat 1 (see point E29)
H23 Circulation pump (optional) and timer E54 Optional thermostat 2 (see point E29)
Shut-off valve E55 Pool pump
Non-return valve E56 Solar pump
Security valve E57 Error signal (dry contact
Thermostatic mixing valve (optional) E58 Pump zone 1
Pressure regulator E59 Pump zone 2
E60 Indoor unit power supply
Boiler circuit pipes
E61 Indoor unit power supply 1 - main
Solar panels circuit pipes
E62 Indoor unit power supply 2 - heaters
Pipes
Connection to the outdoor unit: the outdoor unit power supply
Domestic cold water pipe E63 comes from the indoor unit, so it is not necessary to bring a direct
Electrical wired cables power supply to the outdoor unit.
CZ-TAW1B is a device that can allow the remote control of the heat
pump using a LAN or Wifi connection to the modem. Using this
E64
device the HP can be online on the Aquarea Smart Cloud website
(https://aquarea-smart.panasonic.com).

Attention: All requirements in this page are only examples and they are not a project design specific. Refer always to the documentation provided by Panasonic.
Panasonic is not responsible, directly or indirectly, towards users and in general towards any third party for any delays, inaccuracies, errors, omissions, damages (direct, indirect, consequential, and punishable) arising from such
contents. Texts, photos, graphics, may not be published, rewritten, marketed and distributed by users and third parties in general, in any way and in any form if not expressly indicated in written form by Panasonic itself.