You are on page 1of 1

Customer :SLB PO :

TAG :003500FO1911 Doc :


TAG Fluid :RAWGAS Sales Order:
Fluid Ref. :ENTER RAWGAS Service :GAS
Pipe :316 Stainless Steel Primary :316 Stainless Steel
Meter :Orifice:Choked Flow Taps :Upstream
Coeff Eq :Ward-Smith Calculation:SIZE
Preparer :Jay Printed :4/30/2024 90AB2287
----------------------------------- Flow -----------------------------------
Flow Rate 15891.0 kg/h
Pipe Reynolds Number 4358874.
------------------------------- Measurements -------------------------------
Pressure (Upstream pG1) 44.0000 Bar,gage
Pressure (Downstream pG2) 24.3693 Bar,gage
Choking Pressure Ratio pf2/pf1 0.5639
Barometric 1.0133 Bar,abs
Temperature Flowing 58.9000 degC
--------------------- Fluid Properties @ dry conditions --------------------
Density Flowing 48.4380 kg/m^3
Viscosity 0.0140 cP
Isentropic Exponent(Cp/Cv) 1.2030
--------------------------------- Factors ----------------------------------
Discharge Coefficient(C) 0.83932
Pipe Thermal Expansion (FaD) 1.0006
Critical Flow Function (Ycr) 0.6539
---------------------------- Design Information ----------------------------
Pipe Diameter(D) 92.04000 mm@20.degC
Bore Diameter (d) 26.38038 mm@20.degC
Beta 0.28662 @20.degC
Orifice Minimum Thickness (tPE) 26.3804 mm
Pipeline Velocity V 13.68 m/s
Overall Pressure Loss 19.6307 Bar
Energy Cost 156712. $/year@0.10/kwh

CHOKED/CRITICAL FLOW CONDITIONS

R.W. Miller and Associates The FLOW CONSULTANT TM


Licensed Software 90AB2287 C1987-2024 Version 9.0.7