You are on page 1of 10

MAXWELL Product Catalog

ISO9001:2008 CE

MS-1DA MS-1AA MS-3DA Heatsink


TEMPERATURE CONTROLLER ROTARY ENCODER
SOLID STATE RELAY TEMPERATURE SENSOR

PROXIMITY SENSOR
CAPACITIVE SENSOR

Sales@maxwell-fa.com
Tel:+86-592-6382791
Fax:+86-592-6091734 WWW.MAXWELL-FA.COM
MAXWELL

Temperature Controller/ Solid State Relay /Rotary Encoder/Proximity Sensors/Capacitive Sensors


Single Phase Solid State Relay
480V/660V
MS-1DA Series DC to AC type 5-32VDC
MS-1AA Series AC to AC type 3-15mA DC
A wide range of models with 10 to 120A output currents
Maximum load capacity is 660VAC 8mA

0.1KG

480V/660V
90~280VAC
3-12mA DC
1:Basic Model Nmae
8mA
2:Rated Load Voltage
48: 480VAC
66: 660VAC
3:Rated Load Current

0.1KG

MS-1AA

1:Basic Model Nmae


MS-1AA: Maxwell 1 phase SSR(AC to AC type)
2:Rated Load Voltage
48: 480VAC
66: 660VAC
3:Rated Load Current 5-32VDC 480VAC

MS-1AA4840:single phase AC to AC SSR(40A load 480VAC)


P2/9
MAXWELL Specifications(60VDC Load type)

Temperature Controller/ Solid State Relay /Rotary Encoder/Proximity Sensors/Capacitive Sensors


Single Phase Solid State Relay Load Voltage 60VDC
Control Voltage 5-32V DC
MS-DD Series DC to DC type Control Current 5-50mA DC
A Wide Range of models with 10 to 120A On Voltage Drop 1.5V

V
Output currents and Up to 480VDC output Voltages Off-leakage Current 2mA

V
On-off Time 10mS

V
All models with the same universal standard size
Dielectric Strength 2000V AC
Operation indicator(red LED) enables monitoring operation
Insulation Resistance 500MΩ/500VDC
Protective cover for greater safety
DC input and DC output Ambient Temperature -30 0C~+75 0C
Fast response and robust Mounting Chassis Mount
No noise during the operation Indicator LED
Chassis mount Weight 0.1KG
Mosfet output

Ordering Information(60V DC Load type) Specifications(110/240/480VDC Load type)


Load Voltage 110VDC / 220VDC / 480VDC
MS-DD
Control Voltage 5-32V DC
1 2 3
Control Current 5-25mA DC
1:Basic Model Name On Voltage Drop 2.3V

V
MS-DD: Maxwell 1 phase SSR(DC to DC type) Off-leakage Current 2mA

V
On-off Time 10mS

V
2:Rated Load Voltage
60: 60VDC Dielectric Strength 2000V AC

3:Rated Load Current Insulation Resistance 500MΩ/500VDC


Ambient Temperature -30 0C~+75 0C
10 : 10A
25 : 25A Mounting Chassis Mount
40 : 40A Indicator LED
60 : 60A Weight 0.1KG
80 : 80A
100 : 100A MS-DD6010: DC to DC SSR(10A load 60VDC) Wiring and Dimensions
120 : 120A
Ordering Information(110V/220V/480V DC Load type) 44.8mm
28mm
Load
MS-DD 2- 4.5

1 2 3
1:Basic Model Name 1 2 21mm 28mm

MS-DD: Maxwell 1 phase SSR(DC to DC type)


2:Rated Load Voltage
110 : 110VDC 43mm 57.4mm
LED
220 : 220VDC 1
480 : 480VDC +4 Load

5~32VDC
5-60VDC

Control
_

Output
Circuit
Circuit
3:Rated Load Current 5-110VDC
4 3 24-220VDC +
10 : 10A 24-480VDC
25 : 25A -3 2
40 : 40A 12mm
60: 60A Input
80: 80A 25mm
10 0 : 100A
120 : 120A MS-DD11010: DC to DC SSR(10A load 110VDC)
P3/9
MAXWELL

Temperature Controller/ Solid State Relay /Rotary Encoder/Proximity Sensors/Capacitive Sensors


Three Phase Solid State Relay
380V / 480V / 660V / 1200V
MS-3DA Series DC to AC type 5-32VDC
MS-3AA Series AC to AC type
A Wide Range of models with 10 to 200A Output currents
Up to 1200VAC output Voltages
All models with the same universal standard size
Operation indicator(red LED) enables monitoring operation
Protective cover for greater safety
Built-in RC Snubber
Fast response and robust
Zero cross function
No noise during the operation
Chassis mount

Ordering Information(DC control AC type)


MS-3DA
1 2 3
1:Basic Model Name
MS-3DA: Maxwell 3 phase SSR(DC to AC type) 90~280VAC
2:Rated Load Voltage
3 8: 380VAC
48: 480VAC
66: 660VAC
120: 1200VAC
3:Rated Load Current
10: 10A
25: 25A
40: 40A
60: 60A
80: 80A
100: 100A
120: 120A
150: 150A MS-3DA3825: Three phase DC to AC SSR(25A load 380VAC)
200: 200A
Ordering Information(AC control AC type)
MS-3AA
1 2 3
1:Basic Model Name
MS-3AA: Maxwell 3 phase SSR(AC to AC type)
2:Rated Load Voltage
3 8: 380VAC
48: 480VAC
66: 660VAC
120: 1200VAC
3:Rated Load Current
10: 10A
25: 25A DC Control:5-32VDC
40: 40A AC Control:90~280VAC
Remark: There is no polarity for AC load side
60: 60A
80: 80A
100: 100A
120: 120A
150: 150A MS-3AA3825: Three phase AC to AC SSR(25A load 380VAC)
200: 200A P4/9
MAXWELL Specifications(Resistor input)

Temperature Controller/ Solid State Relay /Rotary Encoder/Proximity Sensors/Capacitive Sensors


Single Phase Power Regulator
Load Voltage 220VAC / 380VAC
MS-1VD Series Analog input Control 0-470Kü (220VAC) 0-560Kü (380VAC)
MS-1VR Series Potentiometer Control Control Current N/A
On Voltage Drop 1.5V

V
A Wide Range of models with 10 to 120Amps
220VAC load or 380VAC load Off-leakage Current 2mA

V
Analog input/Potentiometer input
On-off Time N/A
All models with the same universal standard size
Operation indicator(red LED) enables monitoring operation Dielectric Strength 2500V AC
Protective cover for greater safety Insulation Resistance 100MΩ/500VDC
0 0
Resistance input or Voltage input Ambient Temperature -30C~+75C
Fast response and robust Mounting Chassis mount
No noise during the operation Indicator LED
Chassis mount
Weight 0.1kg

Ordering Information(Resistance input)


Specifications(AC to AC type)
MS-1VR
1 2 3 Load Voltage 220VAC / 380VAC
1:Basic Model Name Control Voltage 0-5VDC/0-10VDC
MS-1VR: Maxwell Voltage Regulator, potentiometer control Control Current DC 4-20mA
2:Rated Load Voltage On Voltage Drop 1.5V

V
Off-leakage Current 2mA

V
38: 380VAC Load
3:Rated Load Current On-off Time 10mS

V
10 : 10A Dielectric Strength 2500V AC
25 : 25A Insulation Resistance 500Mü /500VDC
40 : 40A 0 0
Ambient Temperature -30C~+75C
60 : 60A
80 : 80A Mounting Chassis mount
100 : 100A Indicator LED
120 : 120A
Weight 0.1kg
Ordering Information(Analog input)
Wiring and Dimensions
MS-1VD
1 2 3 4 44.8mm
28mm
1:Basic Model Name 2- 4.5
Load

MS-1VD: Maxwell Voltage Regulator analog input


2:Rated Load Voltage 1 2 21mm 28mm

22: 220VAC Load


3:Rated Load Current
57.4mm
10 : 10A 43mm LED 1
25 : 25A _4 Load

Phase control
40 : 40A

Input Control
60 : 60A 3-32V DC 240VAC
~

circuit
4 3 ~
80 : 80A
100 : 100A +3
120 : 120A 2
12mm
4:Input Signal Input
A: 0-5VDC 25mm
57.4L * 44.8W * 28H
B: 0-10VDC Specification of MS serials SSR are subject to change without prior notice
C: 4-20mA
P5/9
MAXWELL Wiring Diagram

Temperature Controller/ Solid State Relay /Rotary Encoder/Proximity Sensors/Capacitive Sensors


Three Phase Power Regulator A
Basic Type B Three phase
MS3-VD Series Analog Control 380VAC
C
N
MS-3DA/AA Serials
Linear phase-shift control, excellent stability, high precision
Modularized design, safer and reliable
Small size, easy to install and wiring
Vacuum welding technology, good quality and robust. A1 B1 C1
Input
Rated voltage: Three phase 380VAC(four wires) N
Rated voltage for cooling fans: 220VAC +5V
Rated amps: 10A/25A/40A/60A/80A/100A/120A CON
Frequency: 50/60HZ Control signal
COM
Control signal: 4-20mA , 0-5VDC, 0-10VDC. Output
0 A2 B2 C2
Ambient temperature: Maximum temperature 47C
Maximum humidity 90%RH

Ordering Information

MS3 4:Rated Load Current


LR1 LR2 LR3
1 2 3 4 10: 10A
25: 25A
40: 40A
1:Basic Model Name 60: 40A
Ms3: Maxwell Three Phase 80: 80A
Power Regulator
100: 100A Dimensions
2:Control Type 120: 120A
W
VD: Linear Control 5:Control Signal
Installation dimensions: W(90mm)*L(80mm)
A: 0-5VDC input
3:Rated Load Voltage B: 0-10VDC input Overall dimensions: W(100mm)*L(110mm)*H(145mm)
38 : 380VAC C: 4-20mA input A

MS3-VD3825A: Three phase power regulator 25A with control signal as 0-5VDC L
A

B
Specifications B

Rated voltage 380VAC Warning and Precautions(very important)


Rated current 10A/25A/40A/60A/80A/100A/120A
1:The main circuit adopts three-phase four wire input without requirement for phase sequence
Operation frequency 50/60HZ
2:SCR with high amps of current flow through, be sure to tighten the terminal (A1 B1 C1 and A2 B2 C2)
Output mode Phase output at its maximum extend. otherwise SCR might be damaged by heat generated around the terminals.
4-20mA 3:When Y connection used for load, the center of Y should be connected with zero line, otherwise,
relative equilibrium of the three phase is required
Control signal 0-5VDC 4:When load greater than 15KW, Heatsink is a must for the SCR, and heat conducting silicon grease
0-10VDC should be applied between chassis of SCR and the heatsink, and cooling fan is a must for the heatsink
Ambient
0
Maximum temperature 47C/Maximum humidity 90%RH 5:Make sure to use semi-conductive fast fuse for overload protection
6:Make sure to pick proper heatsinks when load more than 15KW
Cooling fans 220VAC

P6/9
MAXWELL Dimensions and Wiring Diagram

Temperature Controller/ Solid State Relay /Rotary Encoder/Proximity Sensors/Capacitive Sensors


Three Phase Power Regulator
R
Advanced Type S
HMS3-VD Series Linear Control T

NBF H

Linear phase-shift control, excellent stability, high precision, compact design R S S


Modularized design, safer and reliable PL 380VAC

LED INDICATOR
Over temperature protection(Maximum temp is 70 C) IN INPUT
Built-in fast fuse protection FU FU FU OUT OUTPUT
LED Indicator
Adjustable minimum and maximum output FB FAST FUSE L
Rated voltage: Three phase 380VAC(four wires),maximum 800VAC
Rated voltage for cooling fans: 220VAC
Rated Amps: 10A/25A/40A/60A/80A/100A/120A/150A/200A/250A/300A W
Frequency: 50/60HZ
Control signal: 4-20mA , 0-5VDC, 0-10VDC. Overall size:190mm(W)*350mm(L)*215mm(H)
0
Ambient temperature: Maximum temperature 47C
Maximum humidity 90%RH M + - W

Input
Min output Bias

Max output Bias


Internal 5VDC
BIAS BIAS
Ordering Information
U V W
W1
HMS3 Section 4:Rated Load Current
1 2 3 4 10: 10A LOAD
25: 25A
Section 1:Basic Model Name 40: 40A L L1
60: 40A
HMS3: Maxwell Three Phase Power Regulator 80: 80A
All in one advanced type 100: 100A Phase Control
Section 2:Control Type 120: 120A
150: 150A
VD : Linear Control 200: 200A
250: 250A
Section 3:Rated Load Voltage 300: 300A
Mounting size:170mm(W1)*130mm(L1)

38 : 380VAC
Section 5:Control Signal
Add-On Features
A: 0-5VDC input
B: 0-10VDC input Maximum and minimum output adjustable
C: 4-20mA input LED indicator
HMS3-VD38250C: Three phase power regulator 250A with control signal as 4-20mAVDC Over temperature protection
Built-in fast fuse protection
Specifications Compact design
Rated voltage 380VAC
Warning and Precautions(very important)
Rated current 10A/25A/40A/60A/80A/100A/120A/150A/200A/250A/300A
Operation frequency 50/60HZ 1:The main circuit adopts three-phase four wire input without requirement for phase sequence
Output mode Phase output 2:SCR is a product with big current, please keep in mind that terminals(R,S,T) and (U,V,W) shall not be
4-20mA
locked too tight, or SCR will be burned by terminal heating.
3:When Y connection used for load, the center of Y should be connected with zero line, otherwise,
Control signal 0-5VDC relative equilibrium of the three phase is required
0-10VDC 4:When the temperature of radiator exceed 70C, the module will stop working automatically, and the only
0 power indicating LED is light on at the moment.
Ambient Maximum temperature 47C/Maximum humidity 90%RH
Cooling fans 220VAC
P7/9
MAXWELL Specifications(480V Load)

Temperature Controller/ Solid State Relay /Rotary Encoder/Proximity Sensors/Capacitive Sensors


Three Phase Reversing Solid State Relay
Load Voltage 480V
MS-3M Series Control Voltage 10-30V DC
Control Current 10-30mA
On Voltage Drop 2V

V
Off-leakage Current 10mA

V
Reversing time duration 300mS

V
A Wide Range of models with 10 to 120A Output currents
Up to 660VAC output Voltages Dielectric Strength 2500V AC
Insulation Resistance 1000M Ω/500VDC
All models with the same universal standard size Ambient Temperature 0
-30C~+75C 0

Operation indicator(red LED) enables monitoring operation


Mounting Chassis mount
Protective cover for greater safety
Indicator LED(Red Green)
Built-in RC Snubber
Fast response and robust Weight 0.3KG
Zero cross function
No noise during the operation Specifications(660V Load)
Chassis mount
Load Voltage 660V
Ordering Information(480V Load Type) Control Voltage 10-30V DC
Control Current 10-30mA
MS-3M On Voltage Drop 2V

V
1 2 3 Off-leakage Current 10mA

V
On-off Time 300mS

V
Section 1:Basic Model Name Section 3:Rated Load Current
Dielectric Strength 2500V AC
MS-3M: Maxwell 3 Reversing SSR 10: 10A
Insulation Resistance 1000M Ω/500VDC
25: 25A
0 0
Section 2:Rated Load Voltage 40: 40A Ambient Temperature -30C~+75C
60: 60A Mounting Chassis mount
48 : 480VAC
80: 80A
Indicator LED(Red Green)
100: 100A
Weight 0.3KG
MS-3M4825: Three phase reversing solid state relay
660V Load Wiring and Dimensions
MS-3M
1 2 3
105
Section 1:Basic Model Name Section 3:Rated Load Current 90+/-0.1
Corotation
+
-
MS-3M: Maxwell 3 Reversing SSR 10: 10A Reverse
+
25: 25A
Section 2:Rated Load Voltage 40: 40A

48+/-0.1
60: 60A C1 C2
66 : 660VAC

74
80: 80A LED R Rv

M
B2
100: 100A 2- 4.5
B1 V
R Rv A2
4.8
A1 V
MS-3M6625: Three phase reversing solid state relay

33mm

P8/9
MaxWell Ordering Information(For Three Phase SSR)

Temperature Controller/ Solid State Relay /Rotary Encoder/Proximity Sensors/Capacitive Sensors


Accessories for SSR MW-L HeatSink
Unit:mm View from the top

Heatsinks for SSR,SCR. 150

Cooling Fans for SSR HeatSinks and Fans


88(L) Unit Weight: 0.4KG

35
MS-3DA/AA Serials SSR and HeatSink Compatible checking list
ITEM NO SIZE Compatible SSR Remark 150(W)

MW-I 60x50x50 10A/25A Single Phase SSR


MW-W-A 72x100x50 40A Single Phase SSR
MW-W-B 100x100x50 60A Single Phase SSR Compatible SSR: Three Phase SSR with load at 10A/25A.(150*88*35)
MW-T 80x80x70 80A/100A/120A Single Phase SSR
MW-L 150x88x35 10A/25A Three Phase SSR
MW-H-A 110x80x80 40A Three Phase SSR MW-H-A HeatSink Unit:mm View from the top
MW-H-B 150x80x80 60A Three Phase SSR MW-H-B HeatSink
80
MW-Y-A 110x125x135 80A Three Phase SSR MW-H-A MW-H-B
MW-Y-B 150x125x135 100A/120A Three Phase SSR
MW-Y-C 170x125x135 150A/200A Three Phase SSR
80 110(L) 150(L)

Ordering Information(For Single Phase SSR) 80(W) 0.5KG 80(W) 0.8KG

MW-I HeatSink 110


Unit:mm View from top
MW-H-A: Compatible with three phase SSR with load at 40A(110*80*80)
80 MW-H-B: Compatible with three phase SSR with load at 60A(150*80*80)
60(L)
50 (W) Unit Weight: 0.1KG

50 (H) MW-Y-A HeatSink


60 (L) MW-Y-B HeatSink Unit:mm View from the top
MW-Y-C HeatSink
125(W)
80
MW-I:Compatible with Single Phase SSR with load at 10A and 25A(60*50*50) MW-Y-A MW-Y-B MW-Y-C

Unit:mm View from top 110(L) 150(L) 170(L)


MW-W-A HeatSink
125 135(H)
MW-W-B HeatSink
100 (W)
MW-W-A MW-W-B
125(W)(1.5KG) 125(W)(1.9KG) 125(W)(2.3KG)
48

50 (H) 100 (L) 72 (L)

MW-Y-A:Compatible with three phase SSR with load at 80A(110*125*135)


100 (W) 0.2KG 100(W) 0.3KG MW-Y-B:Compatible with three phase SSR with load at 100A/120A(150*125*135)
MW-Y-C:Compatible with three phase SSR with load at 150A/200A(170*125*135)
MW-W-A: Compatible with Single Phase SSR with load at 40A(72*100*50)
MW-W-B: Compatible with Single Phase SSR with load at 60A(100*100*50) MF-1-B-8-110/220 MF-1-B-12-110/220
MF-1-B-12- 110 :Ball bearing Fans(110V)
MW-T HeatSink Unit:mm View from top MF-1-B-8- 110 :Ball bearing Fans(110V) Size:120mm*120mm, with Metal Protector
Size:80mm*80mm, with Metal Protector

70(W) MF-1-B-12- 220 :Ball bearing Fans(220V)


MF-1-B-8- 220 :Ball bearing Fans(220V) Size:120mm*120mm, with Metal Protector
Size:80mm*80mm, with Metal Protector

MF-1-S-12-110/220
80 (L) Unit Weight: 0.4KG MF-1-S-8-110/220
80(H) MF-1-S-12- 110 :Sleeve bearing Fans(110V)
MF-1-S-8- 110 :Sleeve bearing Fans(110V) Size:120mm*120mm, with Metal Protector
70 (W) Size:80mm*80mm, with Metal Protector
MF-1-S-12- 220 :Sleeve bearing Fans(220V)
MF-1-S-8- 220 :Sleeve bearing Fans(220V) Size:120mm*120mm, with Metal Protector
Size:80mm*80mm, with Metal Protector
Compatible SSR: Single Phase SSR with load at 80A/100A/120A.(80*70*80) P9/9
MAXWELL ELEC TR ICAL LI MITE D
Add: NO.68 Ji anM ei Li Indu st rial Par k, Hai Cang di st rict , Xi aM en, FuJ ian, Chi na 361 026
Tel : 86- 592 -638 279 1
Fax : 86- 592 -609 173 4
www.max wel l-fa. co m
sa les @max wel l-fa. co m

In ca se we di dn’ t get yo ur e- mai l, pl eas e se nd yo ur inqu iry to our al ter nat ive mai l 129 832 298 3@ qq. co m
Thank yo u ve ry muc h

You might also like