You are on page 1of 32
METASH PRODUCT CATALOG METASH on eecriornnnscais COMPANY INTRODUCTION Since 2008, Metash Instruments has been dedicating to excellence in manufacturing laboratory and scientific instruments, We provide a full range of UVIVIS Spectrophotometers, TOC Analyzer and Microwave Digestion System Premium product quality, competitive market strategy and perfect service are our core competitiveness. With strong global distribution network and good reputation, our products have been sold to 90+ countries and 50,000+ instruments are serving for Environment, Food, Cosmetics, Pharmaceuticals, Life science and Chemical fields, ete We aim to be the leading supplier of analytical instruments worldwide. 50 we always attach great importance to product quality and services. We possess a first-class management team, a strong R&D team and a passionate sales team who are willing to offer you reliable products and satisfactory service OEM or ODM request is also welcomed. We have established stable cooperations with many famous companies based on OEM/ODM. We will continue looking for reliable partners and look forward to growing with you. CONTENTS UVIVIS Spectrophotometer an v-s1001UV-5100 eco] uvsi008 - 03 v-s00/UV-s600 - v-s800/UV-5e00 - of v.90 05 v.6100 Series. ——~ ace) vuv.s000T — - or uv-e0o0TIuv-8000Ts ~ Seaace) v.9000 Series _ 0 Sofware 044 Optional Accessories —~ - 1916 Microwave Digestion System ‘wo s00mmnw0-250 7 ‘MwD-650INNWD-700 18 MWO-610 Series 19 MWDS10Mini — 2 Software ———— a Optional Access1¢§, women 2 Total Organi Carbon Analyzer TOOASOOITOC-7O = 2 Toc-2000/T0C-3000 ‘Optional Accessories |_| V-5000 & Visible Spectrophotometer See eee Re ee eee eae an ‘i ene eee fers high performance, easy operat 1 appicat Features © + Latest Microprocessor Contig System With latest microprocessor contralag, V-S000 could realize Auto Zero and Auto 10037 adjustment only with one button. H equips with 128764 LCD display instead of LED for crect readout of Transmittance, Absorbance and Concentration + Precision 1200 lines/mm Grating Monoctromator ‘The precision 1200 linesimm grating Menochromator ensures high wavelength resolution, high parameters accuracy and low stay light + Easy Data Output by USB/Parallel Port '-5000 equips with 2 USB port which could connect to PC to edi data trough a specific software. The data also can be printed through the parallel port Wen connected to a mcr thermo printer. The PC software and micro printer are optional + Elegant Streamlined Design, Muil-tuncton Operation Systm 'V-5000 hasan elegant streamlined design the compact body ony occupies tle space while it stil equips wih 120mm wide sample compartment {and long optical path monochromator o reserve enough space for optional accessories to realize mult functions. ‘+ Four Display Modes, One-Buton Quick Switching ‘Transmittance, Aosorbance, Concentration and Factor coeciet) mode could be one-button sviched quickly. Technical Specification ote 5000 Phetemetie Mode TAGE pict Sytem | ‘Sng Bear, rang 1200ineinm | Stay Ugh ‘so24T@e00 Wiavelsngh Range | 225-10000m ‘Sbiiy ODA @ 5000 Spectat Bandwiay | om Dinay 28764 Da LCD Wiavelengi Accuracy | 20m Dates ‘icon Proesode WivelongthRepestabiy | 205m Ouput USE Pon Paral Pon Wovelenah Satin | Neanual Uphtsouc Tungsten Halogen Lane ProtomotieAccuney | #0587 Power Requromens | AC8=-250V Photometric Repestabaty | 0.27 ‘rension 20°280°18000 PhotonstieRange | -02-3A OR00KT O99 Wa rm Standard Accessories = creer 2) WB v-s100/uv-s100 a Spectrophotometer 5100 Series includes 2 classic models: V-5100 and UV.5100 'V-5100 only works invisible range while UV-5100 works in bth visible and UV range. Features © + 25 inches highsefniton LOD Display ‘V-5100 and UV.5100 equip witha 25 inches high-def LCD display which clearly shows standard curves and test resus, + Imported Tungsten Lamp and Deuterium Lamp ‘The imported tungsten lamp an deuterium lamp reduce most stray ight which ensures high photometric accuracy. The ula-ong service We and stable working status make V-St001UV.5100 perform perfect. + Standard Curve, Quick Establishing It 5 es9y and quick to estabish various standard curve according to different samples and find the concentration of unknown samples + Easy Data Output, US®/Paalel Port “The USB ports used for PC connection to realize spectrum scanning, Kinetics, mul-wavelength, ete. The Parallel port is used for miro Pinter connection to pit data and standard curve directly. PC software and micro printer are optional, + Mutipe Results Readout, Large Storage Capacity 'S100/UV.5100 could display wavelength, absorbance and transmittance wih § ines of results per page. The large storage capacty could save upto 200 groups of test results + Automatic Wavelength Setting ‘Te wavelength could beset avlomatcaly through arrow keys to avoid misoperaton. Technical Specification Model vstoanw $100 PhatorotieRangs | 023A, o200%T, o.sseec eptc S yer Shglebeam, Grainy 1220inesinm | Phalanetie Mode TAGE ‘Wavslongh Range | 525-000 790-1000%m ‘Seay att eT Speatal Banat | 2m ‘sabi {0.002Ain @ S000m Wavelength Acouaey | 20m iy "2864 Deis CO Wavelength Repestabty | 0m Deter ‘Sion Pots WavelatSating | Auto Oupat USB Por & Paral Port Waele Resouaon | 00m prt Source Tags LarprTungin Larp402 6 Protometie Ascracy | 205% PowerRequamenis | AC8S-250V Phetometie Repesiay | <02%T Dimension 20260800 Wii oKGrKE Standard Accessories = Deion xan Tem Guo ce oe sla /3]e]alalg a UV-5100B & Spectrophotometer ee pi Features © + Low Stay Light LUV-51008 is made o high-quatty optcal components which ensures very low stray ight + Automate Wavelength Setting ‘The wavelength could be set automatically through arrow keys to avoid misopertion, + Rigid Structure, High Stabilty and Durabilty LUV.51008 fs with special rigid inner stucture al optical components ate ited on a special igi! baseboard which eneures high stably and realty. + Easy Data Output ‘The USB pot is used for PC connection to relze spectrum scanning, kinetics, ult-avelongth, ec. The Parallel port used for micro printer connection to Pint data and standard curve direct, PC software and micro printer are optional + Standard Curve, Quick Estabishing It very easy and quick to establish various standard curve according to dfferent samples and find the concentration of unknown samples ‘+ Mutiple Resuts Readout, Large Storage Capacty ‘Wavelength, absorbance and transmitance coud be displayed with 5 lines of resis per page. The lage storage capeciy coud save up to 200 groups of testresuts, Technical Specification Mote esi008 Photemetic Range (03.38, 0 20037, 056580 Opical Sytem | ‘Snglebeam, Graing 120 inecinm | Stay ght =oeeKT@20.80N Wiovslongh Range | 190-1000% ‘sbiiy “oDoTAM @ S0oAm Banca "am Disay 12664 Dot LCD Wiaelongi Accuracy | 1m Daecor ‘icon Proocode Wivelongth Repestabiy | 20.20 ‘ouput USB Por & Paral Po Waving Seting | Auto Lge Sou Turpin Lang Desarum Lamp ‘Wario Resaition | 0.0m Power Requromans | AC 8-200 ProtonoticAccuey | =056T Drension 9070-2200 Photonetie Repesabity | 027 Wa TeKGIEKE Standard Accessories 8 cere Specephsane| Tema ete V-5600/UV-5600 um V-5800/UV-5800 & Spectrophotometer ‘5600 and $800 series Include 4 models: V-5600, UV-5600,.V-S800 and UV-S800, ‘Both series are designed wih precision lead screw structure, it ensures extremely high wavelength accuracy. ‘The 5800 series which with advanced technical specication would be your best choice of single beam spectrophotometer. Features a + Precision Lead Screw Structure Designed wth precision lead screw structure which highly improves wavelength accuracy and wavelength resolution, + Automatic Wavelength Seting “The wavelength could be st automatically through arrow keys o avoid misoperation, + Complete Numerical Keys {All parameters, tke wavelength, concentration, ec. canbe easly set by complete numerical keys. + Easy Data Output ‘The USB port is used for PC connecton to realize spectrum scanning kinetics, uit-wavelongth ee. “The Parallel ports used for micro printer connection to print data and standard curve directly, PC software and micro printer are optional + &mm-bick Optical Base {All optical components are fixed on an &mm-thick rigid le-cast aluminum board which ensures high stabilty and eabilty. + Imported Tungsten Lamp and Deuterium Lamp ‘The imported tungsten lamp and deuterium lamp reduce most stray ight which ensures high photometvc accuracy. The ultaong service fe and stable working status make device perform perfect + Standard Curve, Quick Estabishing Easy and quick to establish various standard curve according to fren samples and ind the concentration of unknown samples Technical Specification « r= vemwen [vane ‘asonuvseoe | vetoauvaece eh S1ORAN @ Sob ea om ary orcence Wowsrghacsiney | s08em Caeser nn Fae Wersersh eves | <2. oI vsesnsoz | UBaRR evar serra | Ae Upusore oe Protmeo resis) _| =O 2a Forres [AC ZV orc TVR oer Reset | 0237 we rene | sane Prosi Rage | 0996 020007 =H ea Ua Tenet oa ee Standard Accessories a Bespin Spaceport Tena oneinara reer TTP TEE 3s |/e/a|a/ 2 a UV-6000 & UV/VIS Spectrophotometer or . ee Se Eee een Features © + inches high-defiriion Large LCD Display Equipped witha 6 inches large LCD display, alldata and graphs can be shown directly and clearly on device screen + Rigid Structure, 8mmthick Optical Base [A optical components ae fixed on an &mm-thick rigid dle-cast aluminum board which ensures high stablty and reliably + Advanced stand-alone system, Powerful Functions "Muti functions ike spectrum scanning, standard curve, kinetics, muti wavelength, DNA/Protsin test can be operated ‘recy on spectrophotometer and all corresponcing curves and data canbe csplayed ect. + Easy Data Output ‘The USB pot is used for PC conection to realize spectrum scanning, kinetics, mult-wavelength ‘The Paral port is used fr micro printer connection to print data and standard curve direct, PC software and micro printer are optional. Technical Specification Node ‘wv-0 ‘Say Lt OWN @ 20er36ONM Wivelongh Range | 190-1100%m Nol “2000084, Banc ‘80m Deny 3207240 Dob LCD WaveloainAccuney | 2050 Detector’ ‘Sion Photsiode ‘Waveonath Repostbiy | <0 2m Os {USB Pot & Paral Pon Protec Accureay | =038T(0-100%7) Lamps “Tungsten Lamp a Destrum Lamp PhotomotieRepesatty | <0.16T PowerRequemenis | AC 220Vis0He or AC 11OVIOHe Photonetie Range 03:38, 020087, 58080 Dimension 280380 100m Wit 20S Standard Accessories evr Specephsme| eS a UV-6100 SERIES & Single Beam Spectrophotometer UV-6100 series is the advanced scanning UV Visible spectrophotometer which combines all best features of single beam “spectophotometers. isthe most ideal choice of stand-alone spectrophotometers. ‘3 madels ae included in this series: UV-6100, UV-6100A and UV-6100S. Features © ++ 520mm Long Light Path “The unique 520mm long ight path design greatly improves the wavelength resolution and make the bandwidth reach O.Snm. “Muti Funetions, Advanced Stand-alone System Wavelength scanning, Standard curve, Kinetics, Mu wavelength scanring, DNAVProtin test could be realized on device irecty without PC sofware, The standard curves and fest results wou be shown on device recy 2s vel, ‘16mm Thick Aluminum Optical Base ‘A ‘omvm thick rigid aluminum base is used as the optical mount which ensures high stably and reliably * Convenient Caieration System ‘Te baseline, wavelength, dark curent canbe ealrated alomatcally to keep device in pertect working status, + 6 inches High-definition LCD Display [UV-8100 series equip with a6 inches large LCD lepay to show results and curves. + Data Output “The USB port is equiped for PC connection and the PC software would come standard wah the instrument + Easy Operation by PC Software Spectrum scanring, Standard curve, Kinet, Mut-wavelength scanning, DNAJProten test can also be realized by PC software. The standard curve and test resus ie avalale tobe exported and saves on PC cect Technical Specification # eae ‘Uva ereowuv-6r608 Stay List SDODNT @ 220s 00m Wavelongh Range | 190-11000m eis EDODIA Band ‘enn rm 10208 00m Dis 320724003 LCD Wavelength Accuracy | 0.16656 tons0 20a Detector ‘ikon Proto ‘Wavelength Repestabiy [0 19m uta [USB Por Paatel Por Photomatie Accuracy | 102%T(0.10037) Lampe “Tungsten Lap ad Deaton Lane Photon Repestabny | 01.70.1087) PowerRaguienetis | AC 220V/S0H2 AC 1OVIOHe Protanetie Range ‘O3.3A0 200% 088800 Dimension 6254907206 Wit 292849200 Standard Accessories 4 espn = O UV-6000T & Touch Screen UV/Visible Spectrophotometer Pepeleprnlepel eleiner reer eer eT oy ay eer | = New pane! with toueh Features and Functions © + 8007480 high-efiniion touch sereen cleatly shows test results and graphs, + Ponerful data analysis system with intemal computer hest could eaize multifunctions independent. Like establishing carton cuve, photometric measurement, uanttatve measurement, spectral scanning, kinetics, DNAVProten lest, muit-wavelength analysis and data printing + Optal system adopts suspension design, All optical pats are independenty fixed onthe 6mm thick aluminum {eformation-tee bese to avoid the impact of bottom plate deformation and outside vortion on optical sytem, ‘This premium design grea improve the stably anc reliably ofthe instrument “Convenient data storage and prinng funtion. UV-6000T can be direly connected to the printer for A format data and graph pining, ‘+ Automatic power on self test and system positioning function could inspect and calibrate the deviation before every use ‘+ All test data and analysis reports can be exported to USB disk recy Technical Specification Model vr Saroine ness oO WavelegthRange | 190-11000m Nei 00005, SpearalBenawath | 20m Deay 00°60 Sra ouch exon WavelonginAccuney | 050m Data Output Por USE Pat Wavelogth Repostabity | 0.2m PinPor USB Pon ‘Say Ltt 05ST @ ZoAMIeORM Upitcouce Tungsten Lamps Deioium Lamp Protometicacoaney | SZR/OCOREMeeOOmG | Power Regimens | AC 220VIE0r2 or AC HOWSOHE PhotomeineRepestiy | saisle wna Meroe | Oatear ‘ion Pret Saba 30.001AM@00NM ‘Devension 290360" 80nm PhotometieRange | 020067, 033.08 capeaC Wo 2K Standard Accessories =i — co 3 fala fa]a| |g = L] wv-soooryuv-soooTs Touch Screen Double Beam UV/VIS Spectrophotometer Features @ ‘+ Adopt cual beam optcal system with precision vertcal-ype dual optical path and dual detector. + Imported grating of high performance greatly reduced the stray ight and improved the stably and reliably of device + 10 inches large touch screen, bultin 326 memory, support Bluetooth connection network. + Three operation modes are availabe: Host, Computer and App of mobile phone (Android). + Powerful data analysis system wih internal computer host could realize mui unctions independent. Like establishing calbraton curve, photometric measurement, quentlaive measurement, spectal scanning, kinetics, ONAVProtein test, ‘mult-wavelongth analysis and data printing + Optical system adopts suspension design. All optical parts ae independent fed on the 16mm thick aluminum {deformation ree base 1o avoid the impact of bottom plate deformation ane outside vibration on optical system. ‘This premium design greatly improved the stably and reliaiity ofthe instrument, + Convenient data slorage and printing function. UV-8000T can be dkecty connected to the printer for A format data and ‘gr9ph printing, + Automatic power on self test and system positioning function could inspect and caliorat the deviation before every use. + Al test data and analysis report can be exported to USB disk direct ‘+ PC software isin compliance with 21CFR PART 11 requicements + Graphs support 30 dleplay on PC sofwtar, Technical Specification eae a TY Wonirgh Rares | 10-00 wa a0 Spedatemesiah | 1m cance ‘Ohne ona caaa Wowsrghaesiney | 1010 6h an i0seveial anes | Oa Oumar | USB Pon Wersrgh eves | rm Pe UsS Fen oo wavnT @ monn rr Tiger Lap ec OO Promavencamnsy | RELERETTSO™TO™ | poweRegor | ACIRO/SOReo AG HOVER ProraoReneaiy| SEISLESET LER | Ome Sen Poke sty tbh gs os GaP 372I0nm Frommers | C208, 050K CORE wee Eo Standard Accessories Desrson Siete UV-9000 SERIES u Double Beam UV/VIS Spectrophotometer o- Uv-8000 series are wide screen double beam spectrophotometer They adopt couble beam long light path design to ensure high stabilty and accuracy and they are the best choice ot high quality spectrophotometers. Features © + Dual Beam Light Path Design {Uv.9000 series adopt double ight path design it greatly reduces excuit actuation and stray ight and ensures high stably ofthe instrument ‘+ Powertul Stand-alone Operation System Ly.9000 eeries are eugjpped with stand-alone operation eystem. Functions lke spectrum scanning, standard curve, knee, mut wavelength scanning, DNA‘Protein test, et. can be directly completed on device without connecting PC software. * Long Light Pan Design “The unique 520mm long lightpath design is adopted fo improve the wavelength resolution and make the bandwidth of UV-9000S can be ‘stoned to 0.Sre, + UV Analyst PC Software PC sotwareis provided to connect device wth PC for easy data output and analysis, the functions inde wavelength scanning, standard curv, Kinetics, mui wavelength scanning, ONAVPltzin test, tc. ‘+ 16mm Rigid Aluminum Optical Base ‘Aig 16mm thick ce-cast aluminum base is used as the optical mount to ensure high stably and relay. + One-button Automatic Calration Systm “The baseline, wavelength ané ark current can be calibrated automaticaly to heep device in good running coaliions.. +6 inches Large LCD spay Equipped wit a 6 inches large LCD csplay to show results and curves rectly onthe screen. + Easy Data Output and Printing Equipped wih USB port to connect with PC, easy to export and pit dala and analysis report Technical Specification 1 Mosel ‘uvao0o | uv.scooa [wv.sooes | Seayught ‘SOSA @ 22003600 opel Syst Dosble Bear(200 Lnesinmn Grating) | Sti 000034 @ 80d Wavelongh Range | 180-11000n Nolo "000064 ‘Banas “ann [tan [oasnsasom [NDB 320°240 Dobe LCD Wavelength Accuracy | 20-1nn(02.686-1j203eme tut ango | Detocor ‘icon Protcode Wvelnath Repostabity | 20.10 una [USS Por &Paralel Por PhotometieAcouaey | +0.28T(0-10%T) Lanes Tingsten Lap & Deuterium Lane Photometie Repeataiy |” 0.1%70-100%7) Power Reguiemris [AC 220V/0H or AC TOVBORE PhetometieRange | -033A, 02005, 0.59986 Dimension 25420206 Wisi ‘KGRIKGKS Standard Accessories Speaphsanat ena ane wren ‘Git B/E SIRS) ERIE VAS Spectrophotometer SOFTWARE UV-SPA/DPA & UV Analyst WORLDWIDE SERVICE QQ O UV/V-5 SERIES/UV-6000T/UV-8000T » Spectrophotometers < Software > LUV-SPAIDPA analysis software is a new version of PC software for V-SIUV-S series and UV-6000T/8000T/6000TS UV-Vis ‘Spectrophotometer designed by Metash engineers. thas powerful functions, such as instrument control, measurement, data analysis ‘and data processing. User management, fle security and 2D display are also avalabe. The main measurement functions contain Photometric Analysis, Quantitative Analysis, Kinetics Analysis, Wavelength Scan, Mul-wavelength Analysis and DNAVProten Analysis. Basic Test (Photometric Analysis) eee Quantitative Analysis + Peanut eat ; 3) ) Wavelength Scan Multi-wavelength Analysis Tinsieen DNA/Protein Analysis. Etmaye te Spectrum Calculation O UV-6/9 SERIES = Spectrophotometers < Software > ‘Metash UV /VIS analyst's the PC control software which is compatible with Metash ‘Uv.6/9 serles of spactrophotometers..t offers the following functions. Quantitative Upto 10 standard samples can be used to establish a curve four methods fr fitting a curve through the calibration points Linear fit, Linear fit through zero, Square fitand Cubic ft I Cootficient Method IH Standard Curve ane aaa DNA/Protein Test Concentration and DNA purty are quickly and easily calculated: [Absorbance ratios 260nm/280nm with optional subtracted absorbance at 320nm DNA concentration=62.9°A260-36.0°A280 Protein concentration=1552°A260-757.3°A280 Standard Curve Lp to32 wavelengths can be selected and multiple samples can be measured, TA Kinetics This mode may be used for time course scanning or reaction rate calculations. 1H Abs. vs time graphs is displayed on the sereen in realtime. IE Wait time and measurement time up to 12 hours may be entered with time intervals of 0.5, 1,2,5,10,30 seconds and 1 min, 1 Post-run manipulation includes re-saling, curve tracking and selection and of the part of the curve required forthe rate calculation, Rates calculation. Rate i calculated using linear regression algorithm before multiplying by the entered factor. Wavelength Scan IE The wavelength scan intervals are 0.102, 05, 1,2, 5am IE High, medium and low scan speeds are avalable. They vary from 100 to 3000 nm/ min. IE avelengths are scanned from high to low so that the instrument waits at high WL. [m] Spectrophotometer Accessory 1 ‘All spectrophotometers are shipped out with standard accessories. The accessories below can be separately ordered once needed. Manual 10mm 8 Cell Holder o Quartz Cuvettes Printer Sipper System Peltier System Za ‘Tungsten Halogen Lamp, Deuterium Lamp 16 10mm 4-Hole Cell Holder ‘Transparent Film Holder METASH 2 ‘Automatic 10mm 8 Cell Holder ws ie TestTube Holder Printer |_| MWD-800/850 & Microwave Digestion System Features © + Special Designed Sample Digestion Vessel ‘The automatic vent and selreseaing structure which won national patent ensures the digestion vessels can automaticaly relesse pressure and instantly reseal when a sucden overpressure situation occurs. I prevents waste of batch samples and solutions and also avlds vessel damage. + Contactless Temperature and Pressure Monitoring System ‘The advanced contactess IR sensor could measure the real-time lemperature of sample solutions in each digestion vessel Meanwhile, the contactless pressure sensor could monitor the real-time pressure of each vessel, This realizes isolation between temperature and pressure controling system, also avoids sample cross-contamination. Each reabtime temperature and pressure value is csplayed during the whole digestion process allowing a clear check of digestion conditions. + Large Storage Capacity Itcan ect and store 255 types of programs according to user's requirements and each method program can set parameters (temperature, pressure, tie, ‘microwave power) according to their own requirements which provides convient operation for users. + Safety Protection System \With high-strength double locked secunty door, the real-ime temperature and pressure monitoring, auiomaic adjustment of overpressure and ‘over temperetre and abnormal sound monitoring, the device can run in highly safe environment + Power Adjustment ‘The variable frequency resonance or non-pulseptonal continues rotting mode ensures high efclent and even microwave throughput. can be set between 0-3000W” according to user's requrements. Technical Specification ‘oss Qnty $0 veo 750 vss “erworatre Cont | Scanning contol ofeach wos ess vle Ed Pressure Tesing Contactos pressire sensor TerpeatireMenitoing | Conacves sere Vestal matra a aay Tinos Touch Saeen Pressure Contctrange _|_0-0NPa aemunengPremre | 6NPa ee Tengrure Comet Raron_| 50-00% Pore (AG 2, GA SHOR Dinero 4730°5900m Woke 7eKo unm veneeenpenie | 250% Terpwcie castor | 20570 Toes Tenge | 2007 Merowave Frequency | 2450H= Rotation Mode 380 Corot Reaon Merowave Leak elon Mironave Power 0500 rte a MWD-650/700 & Microwave Digestion System Features © + Special Designed Sample Digestion Vessel ‘The automate vet and seltreseaing structure which won national patent ensures the cigeston vessels can automaticaly release pressure and instantly reseal when a susden overpressure situation occurs. I prevents waste of batch samples and solutions and also avoids vessel damage. + Contact-ess Temperature and Pressure Monitoring System “The advanced contactless IR sensor could measure the real-time temperature of sample sluons in each digestion vessel. Meanwhile, the conact-ess pressure sensor could monitor the realtime pressure of each vessel, This realizes isolation between temperature and pressure controling system, also ‘avoids sample cross-contamination. Each realtime temperature and pressure vale is splayed during the whole digestion process, allowing a clear ‘check of digestion conditions. + Large Storage Capacity Ihean edit and store 255 types of programs according to user's requirements and each method program can set parameters (temperature, pressure, time, microwave power) according to their oun requirements which provides convenient operation for users, + Safety Protection System ith high-strength double locked security door, the real-time temperature and pressure monitoring, automatic adjustment of ove-pressure and ‘over-temperature and abnormal sound monitoring the device can run ina highly safe environment. + Power Adjustment “The variable frequency resonance or non-puse(optional continues rotating mode ensues high efficient and even microwave throughput. can be set between 0-2000WV10-3000W according to user's requirements Technical Specification © ese Quanity 12 Vessale 18 Vessels Temperate Contal [Scaring cont ofeach vee! Vessel Vou | 100 Pressure Testing Contacts presse sensor “Tenperaire Moning | Covacoss seer Vessel materi eee Dear inches Touch Sern Pressure Cowoliange | -'0NP3 MeemamvotinaPewe_| BMPs PremreCowsiAcaree | OO1Pa TenpentreConaiRange_| 50-4000 Power AG 2200 AOA SOE Dimension oro Weigh ToKan=KG Neon verraTenerne | 250 TenewotrecanriAcney | 20.30 er eta Tenpostesune | 2007 MezcvaveFrequancy | 2450%e etaon Mee "0 Cont Roan Miscwave Leak Emon Marne Power (2I00W Aauiabi @S0C0W Aan a MWD-610 SERIES @ Microwave Digestion System [MWD.610 series is new series of microwave digestion system which launched in 2019, Nis newty designed an tly upgraded with higher performance and safer protection system, ‘The smart design and pertect performance make it warmly welcomed by users wordwide. Features ‘= Optional vessel quantity, up to 12 vessels to meet diferent cigestion requirements, «Vertical design for even cstibution of microwave, ‘+ Realsime montring fr bo temperature and pressure of each vessel ‘= Contactless sensor monitoring with no burst disk design saves consumables cost and maintenance cost. «+ Imported vessel material for both sample vessel and protection vessel highly ensures safety, ‘*Tinch color Teuch screen with user-friendly interface for easy operation ‘+ Imported CFRP outer shell material with high strength ensures impact resistance ‘+ Pre-installed general standard methods, users can also create, save, mosity and delete the method, ‘+3161 industrial etainlees tel cavity wth multlayer teflon coating avoids acid cortsion, also improves cootng efficiency, Technical Specification a Mode MND SIOTS MWO-80TS Ma 610-T10 Mmwo-610712 Vessel Quant é @ 0 2 “Temperate ‘Temperature Mentering:Conaces IR Sensor, Sean entering for ach vescl onterna Sytem Temperature Convling Range: S0~400T; Temperature Acsracy20.1C: Display Accraoy. 20.1% Procure Prossure montong: Comatose Sensor Scan mantoting fo eachvesol Montoring System Pressure Corrling Range O-16NPaProsaure Acoaacy::O.0'MPe Dipay Accuracy 2001Npa "Vesa Vaure "oom SanplaVersl Matra) | inponca TF Protec Vessel Matral | Pook Glas Fiber Dey inch Tuch Seon Ratan 360 Covers Retsng lerowave Ta 6L lanes il ark With Caron Pow Costa Merowave Power 0-100 (Aeuable) MieowaveLeatage | Measure One-click operation, real-time measurement data displayed. 2.Automatic save of measurement data when test finished. 33Real-time monitoring of UV Lamp and Pump Tube with automatic prompt when out of service. 4.Quick cleaning, cleaning time and speed can be set as required, 5.User interface can be lacked to ensure data safety 6.Sampling site can beset under ONLINE mode. Rolling update of measurement data under ONLINE mode. History « -LHistorical measurements can be retrieved by date search, 2.Data displayed clearly and can be deleted as need, 3.Alarm record can be retrieved and exported out. 4'Sampling site, date, time and data recorded in details under online mode. System Setting « Calibration data, Service life of consumables and Alarm value can be easily set. 2.System time can be set according to different time zones. 3.Factory reset is available to restore defaults. 4.User or Admin password can be reset. TOC-2000/TOC-3000 « Total Organic Carbon Analyzer < Software > Standard Curve « Real-time monitoring of temperature and airflow with automatic prompt, 2Fitted equation of standard curve and test data can be stored and rtrived easly The data of standard curve can be exported out as Excel or POF files Measure ‘batch testis avilable with clear data dsplay, easy to make comparisons. Real-time display of peak changes. $3History data can be inquired and retrieved quickly. Data # 1.Quick search according to conditions tke Sample ID, Test time, ete 2.Data under same test concitions can be exported by groups for clear comparison, 23.Test data can be stored as curve with peak, easy to compare with historical data, Log {.Users' each operation can be traced and managed, comply with 21 CFR Part 11 requirements 2.Log can be exported out as Excel or POF files fr easy check Shanghai Metash Instruments Co.,Ltd. ee ee {GPP seo, no18, 127 na Raa, Sona Di Shang 20161, china VIZ. mat oversesstametash com / metash@163.com 0

You might also like