Professional Documents
Culture Documents
AF09
AF09
4 kW
5 hp
Ordering Details
IEC UL/CSA Control voltage Main Auxiliary Type Order code EAN Weight
Rated 3-phase Uc min. ... Uc max. contacts contacts
power motor fitted
400 V rating Pack(ing)
AC-3 480 V 1 piece
kW hp V 50/60 Hz V DC kg
3-pole Contactors
4 5 24...60 20...60 3 0 0 1 AF09-30-01-11 1SBL 137 001 R1101 3471523110113 0.270
48...130 48...130 3 0 0 1 AF09-30-01-12 1SBL 137 001 R1201 3471523110120 0.270
100...250 100...250 3 0 0 1 AF09-30-01-13 1SBL 137 001 R1301 3471523110137 0.270
250...500 250...500 3 0 0 1 AF09-30-01-14 1SBL 137 001 R1401 3471523110144 0.310
Note: AF09-30-01-11 not suitable for a direct control by PLC-output. AF09-30-01-11 available in some countries: please consult your ABB representative.
Pos. 4
Pos. 3
Max. N.C. built-in and add-on N.C. auxiliary contacts: see accessory fitting details for a
3-pole contactor AF09 ... AF38
Mounting distances The contactors can be assembled side by side.
Fixing
on rail according to IEC 60715, EN 60715 35 x 7.5 mm or 35 x 15 mm
by screws (not supplied) 2 x M4 screws placed diagonally
Connecting Characteristics
Main terminals
AF contactor AF contactor
(without top mounted
coil terminal block) A2
Fixing clips
AF contactor A2
ssories
cks
ght side
VM4 2-pole CAT4-11
1-pole
CA4, CC4
4-pole CA4
2-pole CAL4-11
TF42 1-pole
EF.. CA4, CC4
TF42
EF..
kg (1 pce)
Additional auxiliary Front-mounted instantaneous 0 1 - - CA4-01 1SBN 010 110 R1001 3471523130029 1 0.014
contact blocks auxiliary contact blocks
Front-mounted auxiliary contact - - 0 1 CC4-01 1SBN 010 111 R1001 3471523130432 1 0.014
blocks with N.O. leading contact and
N.C. lagging contact
- - 1 0 CC4-10 1SBN 010 111 R1010 3471523130425 1 0.014
Side-mounted instantaneous auxiliary 1 1 - - CAL4-11 1SBN 010 120 R1011 3471523130043 1 0.040
contact blocks
Mechanical and electrical interlock 1 1 - - VEM4 1SBN 030 111 R1000 3471523130616 1 0.035
set
Connection accessories Connecting links with manual motor BEA16-4 1SBN 081 306 T1000 3471523130739 10 0.025
for starting starters
Connection sets for reversing BER16-4 1SBN 081 311 R1000 3471523130777 1 0.045
contactors
Additional coil terminal Additional coil terminal block LDC4 1SBN 070 156 T1000 3471523130678 10 0.010
block
Protective covers Protective covers BX4 1SBN 110 108 T1000 3471523130708 10 0.006
Function markers Function markers BA4 1SNA 235 156 R2700 3472592351568 16 0.011
Note:
- CAT4: not fittable on AF..Z contactors with DC control voltage 12...20VDC.
- VM4: includes 2 fixing clips (BB4) to maintain together both contactors.
- VEM4: includes a VM4 mechanical interlock unit with 2 fixing clips (BB4), a VE4 electrical interlock block and A2-A2 connection.
VE4 block must be used with its A2-A2 connection to respect the electrical connection diagram.
VEM4 not fittable on AF..Z contactors with DC control voltage 12...20 V DC.
NC
NC
A2 2T1 4T2 6T3 22
AF09-30-01-.. / AF09Z-30-01-..
NC
AF09-30-01-.. / AF09Z-30-01-..
6 0.24"
35 mm EN/IEC 60715
35 mm EN/IEC 60715
60 2.36"
2.36"
80 3.15"
80 3.15"
70602.76"
70 2.76"
5.5 0.22" 5.5 0.22"
5 0.20"
5 0.20"
10 0.39" 10 0.39"
5 0.20" 5 0.20"
AF09 AF09
6 0.24"
35 mm EN/IEC 60715
35 mm EN/IEC 60715
5.5 0.22"
80 3.15"
80 3.15"
43 1.69"
5.5 0.22"
10 0.39"
AF09 AF09
+ CA4, CC4 1-pole auxiliary contact block + CAL4-11 2-pole auxiliary contact block
35 mm EN/IEC 60715
35 mm EN/IEC 60715
80 3.15"
80 3.15"
43 1.69"
5.5 0.22"
43 1.69"
5.5 0.22"
AF09 AF09
+ CA4 4-pole auxiliary contact block + CAT4 2-pole auxiliary contact and coil terminal block
102.5 4.04"
102.5 4.04"
90 3.54"
90 3.54"
71 2.80"
71 2.80" 10 0.39"
10 0.39"
80 3.15"
80 3.15" 2x 2x
5.5 0.22"
5.5 0.22" M4 8-32
M4UNC
8-32 UNC
35 mm EN/IEC 60715
35 mm EN/IEC 60715
91.5 3.60"
91.5 3.60"
60 2.36"
60 2.36"
43 1.69"
43 1.69"
70 2.76"
70 2.76"
5.5 0.22"
5.5 0.22"
5 0.20"
5 0.20"
ø 4.2 0.17"
ø 4.2 0.17" 5 0.20"5 0.20"
AF09 AF09
+ VEM4 mechanical and electrical interlock set + VEM4 mechanical and electrical interlock set
(24/03/11)
particulars shall prevail. ABB does not accept any
F-69685 Chassieu cedex / France responsibility whatsoever for potential errors or
possible lack of information in this document.