Service Data Vickers®

Vane Pumps

Vane Type Double Pump


(F3)-4525V(M)-**A(M)**(F)-**-22-*

Rev. 07-01-97 I-3208-S


 Inlet Cover End Cover End
Model  Rotor  Vane kit  Ring
Plate  Cart. Kit  F3 Cart. Kit
4525V***12 584610 02-102536 02-102544
4525V***14 584618 02-136719 584612 588689 02-102537 02-102545
4525V***17 584614 02-102538 02-102546
4525V***21 584616 02-102539 02-102547

 580921 Outlet Plate


 Ring (See Table)

 578900 Rotor
 578903 Inlet Plate

 280888 Pin (2 Req'd)

 229662 Pin (2 Req'd)


 Inlet Plate (See Table)
 Ring (See Table)
 Vane Kit See Table)
(Includes 10 Vanes
& Inserts)
 Rotor (See Table)

 02-136718 Vane Kit


(Includes 12
Vanes & Inserts)

 289476 Screw (2 Req'd)

Housing (See Table)


 289472 Screw (2 Req'd)
237138 Bolt (4 Req'd)
Torque 360 Ć 374 N.m.
(255 Ć 275 lb. ft. )
 588690 Outlet Plate
  419673 Seal Ring
  154078 O"RIng
  588507 Ring
  154095 O"RIng
Cover (See Table)

11163 Bolt (4 Req'd)


Torque 88 - 102 N.m.
(65 - 75 lb. ft. )  Included in shaft end cartridge kit
 Included in cover end cartridge kit
 Included in seal kit 922865
F3 equivalent seal kit 919345
 Included in foot bracket kit FB-C-10
 Assemble seal with spring loaded
sealing member towards bearing. Seals
to be completely wetted with oil prior
to assembly.
 Install 419675 sealing ring into body,
 Eaton Hydraulics, Incorporated 2000 then install cartridge kit.
All Rights Reserved
Shaft End Shaft End
MODEL  RING  CART KIT
 F3 CART KIT
4525V42 581679 02-102572 02-102576
4525V50 581680 02-102574 02-102577
4525V60 578904 02-102575 02-102578

Body S/A (See Table)

Key (See Table)


Shaft (See Table)

 205077 Foot Bracket

 205533 Screw (2 Req'd)

  394974 Shaft Seal


194878 Retainer
131812 Bearing
102949 Retaining Ring
158630 Retaining Ring
  588509 Ring
  154087 O" Ring

   419675 Seal Ring

 154107 O"Ring

MODEL COVER HOUSING BODY S/A SHAFT TYPE KEY


4525V**A 231532 942356 233524 (1) keyed 217596
4525V**E 242250 370071 942356 233527 (11) splined -
4525VM**A 231532 02Ć136925 361762 (86) keyed 239751
4525VM**AM 478511 875778 02Ć136926 850614 (192N) keyed 472303

NOTE
For satisfactory service life of these
components in industrial applications,
use full flow filtration to provide fluid
which meets ISO cleanliness code
16/13 or cleaner. OFP, OFR, and OFRS
series filters are recommended.
Model Code

1 2 3 4 5 6 7 8 9 10 11 12

1 Special seals 6 Port connection modifier 10 Port orientation


M - Metric port connection (Viewed from cover end of pump)
2 Series designation (4 bolt flange)
With no. 1 outlet opposite inlet
Omit - Inch thread port connection
Displacements cm3/r (in3/r) (4 bolt flange) AA - No. 2 outlet 135 CCW from inlet
AB - No. 2 outlet 45 CCW from inlet
Model Shaft end Cover end
Geometric displacement AC - No. 2 outlet 45 CW from inlet
4525V 138 - 193 40 - 67 7
AD - No. 2 outlet 135 CW from inlet
(8.41-11.75) (2.47 - Cover end pump
4.13) With no. 1 outlet 90 CCW from inlet
(Rated capacity (USgpm) at
1200 rpm, 6.9 bar (100 psi) BA - No. 2 outlet 135 CCW from inlet
3 Pilot designation
BB - No. 2 outlet 45 CCW from inlet
M - Metric per ISO 3019/2 100A2HW Frame Code cm3/r in3/r BC - No. 2 outlet 45 CW from inlet
Omit - Standard pilot size BD - No. 2 outlet 135 CW from inlet
4525V 12 40 2.47
With no. 1 outlet inline with inlet
4 Geometric displacement 14 45 2.78
CA - No. 2 outlet 135 CCW from inlet
Shaft end pump 17 55 3.39
CB - No. 2 outlet 45 CCW from inlet
21 67 4.13
(Rated capacity (USgpm) at CC - No. 2 outlet 45 CW from inlet
1200 rpm, 6.9 bar (100 psi) CD - No. 2 outlet 135 CW from inlet
8 Mounting With no. 1 outlet 90 CW from inlet
Frame
Code cm3/r in3/r
size F - Foot mounting DA - No. 2 outlet 135 CCW from inlet
4525V 42 138 8.41 Omit - Flange mounting DB - No. 2 outlet 45 CCW from inlet
50 162 9.85 DC - No. 2 outlet 45 CW from inlet
60 193 11.75 9 Shaft DD - No. 2 outlet 135 CW from inlet
1 - Straight keyed
11 - Splined 11 Design
Port connections 86 - Heavy duty straight keyed
5 192N - Straight keyed (M pilot only)
12 Rotation
A - SAE 4 bolt flange
(Viewed from shaft end of pump)
L - Left hand for counterclockwise
R - Right hand for clockwise

Sharp Edges of Vane Must Lead in Direction of Rotation


NOTE
To reverse cartridge kit rotation, remove
the two screws and reverse the location of
LH RH the inlet support plate and the outlet supĆ
LH RH
port plate. Reinstall the two screws hand
tight. Use pump cover to align all sections
of the cartridge. Carefully remove the covĆ
er and tighten the screws.
RH LH
RH LH
NOTE
When ordering spare cartridge parts, it is
recommended they be obtained in carĆ
Cover End Cartridge Shaft End Cartridge tridge kits. Kits are assembled and tested
R. H. Rotation R. H. Rotation for either right or left hand rotation. If left
hand rotation is required, it should be speĆ
NOTE cified on parts order by adding suffix "L" to
Standard right hand shaft rotation cartridges shown. cartridge kit number.
Reverse for left hand rotation.

Printed in U.S.A.