You are on page 1of 4

959GB

3 Item Explanations
Menu
SR Web Monitor The display changes depending on what you select on the menu.

User's Manual Rev.2.0 (1) (2) (3) (4) (5)

Menu
Read this user's manual before using the product in order to achieve maximum
performance.
Keep this manual in a safe place after reading it so that it can be referenced at
any time. Information display

1 Outline
"SR Web Monitor" is a function that can be used to check SR-5000/2000 Series
statistical information from a web browser.
 Statistical information
• Power on time
• Trigger count
Displays the monitor screen. This screen displays the read data
• Statistical information from successful reading (1) Monitor
and the count of successful readings.
• Reading frequency (reading count/minute)
Displays the count of triggers, the reading success rate, and the
(2) Stats
amount of time that has passed since the SR-5000/2000 turned on.
Code reader PC
(3) History Displays the history of the recent reading results.
Web browser Displays information such as the MAC address and firmware
Access (4) Info
version of the SR-5000/2000.
(5) Update Cycle This is the update cycle of the information display.
Statistical
information
(1) Monitor
Operating Environment
Live view
Google Chrome 57 or later
Internet Explorer 11 or later
Web browser Read data
Microsoft Edge 14 or later
Safari 10 or later
Communication port Ethernet
Maximum number of Statistical
5
simultaneous connections information
* Log on as a user with Administrator rights when using the software.

2 Establishing a Connection
and Exiting the Software
Live view Displays the image read by the SR-5000/2000.
Establishing a Connection Read data
This is the data read by the SR-5000/2000. The maximum number
of displayed digits is 32.
1 Open the web browser.
Trigger
This is the number of triggers that have been applied to the
SR-5000/2000.*1
Success This is the number of successful reading operations.
Error This is the number of reading errors.
Statistical
information NG This is the number of verification errors.
2 Enter the IP address of the SR-5000/2000 into the web browser's URL Unstable
This is the number of times that the reading result was below the
threshold.*2 *3
field.
This is the number of triggers that were applied to the SR-5000/
Lost
2000 during timing input.
*1 The upper limit is approximately 4,200,000,000. The value is reset if the upper
limit is exceeded.
When the connection is established successfully, the following screen is *2 Set the threshold of the matching level or the code quality verification results.
displayed. The count is incremented each time that the reading result is below the
threshold.
*3 This item is not supported by and is therefore not displayed for the SR-5000.

Exiting the Software


1 Click the Close button on the web browser.

1 E SR WEB Monitor UM
(2) Stats (3) History

The amount of time that has passed since the SR-5000/2000 turned
Time
on. Recent Read History of the recent successful reading.*1
Trigger The count of triggers that have been applied to the SR-5000/2000.*1 History of the recent reading errors.*1
Recent Error
Frequency Reading frequency. This is the reading count/minute. * Click the id to display the image at the time of the reading error.
Success The reading success rate compared to the count of triggers. Verification Statistical values of code quality verification results.*2
This is the reading count statistics over time. A history of up to 48 Displays statistical information that has been edited with a script.
Read Count Script Stats
hours is retained. * When using this function, see the script reference.
This is the reading time statistics over time. A history of up to 48
Read Time *1 The maximum id value is approximately 4,200,000,000. The id is reset if the
hours is retained.
maximum value is exceeded.
Stability *2
Average matching level. *2 This item is not supported by and is therefore not displayed for the SR-5000.
(Matching level)
Stability Average timeout margin, which is calculated from the decode
(Timeout Margin) timeout time set on the SR-5000/2000 and the actual reading time.*3

Code Position
Statistical value indicating where in the SR-5000/2000 field of view (4) Info
reading was successful.
Bank Success Count Statistical value indicating for which banks reading was successful.
*1 The upper limit is approximately 4,200,000,000. The value is reset if the upper
limit is exceeded.
*2 This item is not supported by and is therefore not displayed for the SR-5000.
*3 Timeout Margin is calculated as shown below.
1 − (actual reading time/decode timeout time)

Information Displays information such as the model type and MAC address.
Use this section to download config files and script files saved on
Configuration
the SR-5000/2000.
Use this section to clear the statistical information. You can also
download detailed information.
Maintenance
* Even when the values are initialized, the "Time" value is not
initialized.

(5) Update Cycle


You can change the update cycle with which SR-5000/2000 information is
displayed.
The shorter the update interval, the greater the communication load.
Setting range 5s, 1s, None

E SR WEB Monitor UM 2
4 Troubleshooting

The connection to the SR-5000/2000 fails even when its


IP address is entered in the URL field of the web browser.
Use the following information as a reference and implement countermeasures.
• Check that the IP address of the SR-5000/2000 matches the IP address
entered in the URL field.
• Send a ping from the host to the SR-5000/2000 to check for network
problems.
• If security software or a firewall is enabled on the PC, temporarily disable this
software.

A connection can be established to the SR-5000/2000


from a web browser, but some data is not displayed.
Use the following information as a reference and implement countermeasures.
• If security software or a firewall is enabled on the PC, temporarily disable this
software.

When you attempt to display an error image on the


History screen, "no image" is displayed.
The probable causes are listed below.
• Images cannot be saved if "Save to RAM" is not selected for the image saving
setting on the SR-5000/2000.
In AutoID Network Navigator, select "Save to RAM" for the setting for saving
images when a reading error occurs.
• Images cannot be saved if a short time such as 30 ms or less is specified for
the length of time to apply timing input to the SR-5000/2000.
Specify a sufficiently long timing input time.

When you attempt to display an error image on the


History screen, "Failed.(ER,TRGIMG,23)" is displayed.
The probable causes are listed below.
• This is displayed during communication between the SR-5000/2000 and
AutoID Network Navigator.
Interrupt the communication between the SR-5000/2000 and AutoID Network
Navigator.

3 E SR WEB Monitor UM
Copyright (c) 2020 KEYENCE CORPORATION. All rights reserved.

E SR WEB Monitor UM 4 193177GB 2030-1 959GB Printed in Japan