You are on page 1of 2

PUMPING MAIN-ZONE IV TO 3G MH2

Following pipe sizes are tried


Velocity Velocity
Size of Present Intermediate Velocity ultimate
Sl No Pumping Q peak Q peak Q peak
Main -3 lpm 90 lpm 105 lpm
-0.05 lps 1.50 lps 1.75 lps
1 350 mm -0.001 m/s 0.016 m/s 0.018 m/s
2 300 mm -0.001 m/s 0.021 m/s 0.025 m/s
3 250 mm -0.001 m/s 0.031 m/s 0.036 m/s
4 200 mm -0.002 m/s 0.048 m/s 0.056 m/s
5 150 mm -0.003 0.085 0.099
6 100 mm -0.006 0.191 0.223

100 mm dia Q peak intermediate is lesser 100 mm dia size

757001587.xls
PUMPING MAIN-NEW LS TO ZONE 3F MH NO 3
Following pipe sizes are tried
Velocity Velocity
Velocity ultimate
Present Intermediate
Size of
Sl No Q peak Q peak Q peak
Pumping Main
-3 lpm 27 lpm 27 lpm
-0.05 lps 0.45 lps 0.45 lps
1 350 mm -0.001 m/s 0.005 m/s 0.005 m/s
2 300 mm -0.001 m/s 0.006 m/s 0.006 m/s
3 250 mm -0.001 m/s 0.009 m/s 0.009 m/s
4 200 mm -0.002 m/s 0.014 m/s 0.014 m/s
5 150 mm -0.003 0.025 0.025
6 100 mm -0.006 0.057 0.057
7 80 mm -0.010 0.089 0.089
mm dia Q peak intermediate is lesser mm dia
100
100 than 1.2 mps .Hence adopt size

757001587.xls