Base Station Controller OML:BSC


A30808-X3247-K240-3-7619

Outputs OML:BSC

Base Station Controller

Copyright Siemens Mobile Communications S.p.A. 2002


Technical modifications possible. Technical specifications and features are binding only insofar as they are specifically and expressly agreed upon in a written contract.

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

This document consists of a total of 911 pages. Insert the document in binder: OML:BSC

Reason for Update


Chapter/Section all Reason for Update New errors and system info added and some errors and system info updated. Updated the annex parts.

Issue History
Issue Number 1 2 3 Date of Issue 07/2002 09/2002 11/2002 Reason for Update First edition for release BR6.0 Second edition for release BR6.0 Third edition for release BR6.0

1 Contents
1 2 3 CONTENTS.................................................................................................................................................3 INTRODUCTION.....................................................................................................................................13 GSM, PROBABLE CAUSES ...................................................................................................................20 06 CLOCK SYNCHRONISATION PROBLEM........................................................................................ 20 159 PLLH NOT READY DUE TO PWRD...........................................................................21 08 DISK PROBLEM .................................................................................................................................. 23 172 DISK NOT ALIGNED ..................................................................................................23 09 EQUIPMENT FAILURE....................................................................................................................... 25 116 MEMT CARD FAILURE..............................................................................................25 117 LICD PERMANENT ERROR .......................................................................................26 119 IXLT CARD NOT IN FRAME ......................................................................................27 120 IXLT SOFTWARE LMT LINK ERROR ........................................................................28 121 IXLT SOFTWARE OMC LINK ERROR .......................................................................29 122 IXLT FIRMWARE NOT READY ..................................................................................29 143 NTW PERMANENT FAILURE ....................................................................................30 144 UBEX PERMANENT FAILURE ..................................................................................33 145 PLLH PERMANENT FAILURE...................................................................................36 146 SN64 PERMANENT FAILURE....................................................................................38 151 LICD ACCESS PROBLEM ..........................................................................................40 155 SN16 PERMANENT FAILURE....................................................................................41 342 SNAP PERMANENT FAILURE ...................................................................................43 158 TOO MANY UBEX INTERRUPT.................................................................................45 161 PERMANENT COMPARISON ALARM ON SN...........................................................46 163 WRONG PCM PARITY FROM LICD ..........................................................................47 171 DISK NOT FORMATTED............................................................................................47 186 IXLT SOFTWARE BAD RESTART ..............................................................................48 187 IXLT SOFTWARE BAD COMMAND...........................................................................49 207 IXLT CARD CORRUPTED..........................................................................................50 212 HARDWARE FAILURE DIAGNOSTIC REQUEST.....................................................51 213 HARDWARE FAILURE ...............................................................................................61
A30808-X3247-K240-3-7619 3

Outputs OML:BSC

Base Station Controller

214 CARD RESERVED FOR TEST ....................................................................................69 215 CARD DIAGNOSTIC FAILED ....................................................................................70 217 PERIPHERAL CARD FAILURE DIAGNOSTIC REQUIRED.....................................73 218 PERIPHERAL CARD HARDWARE FAILURE ...........................................................76 254 ENVA REGISTERS MISMATCH .................................................................................79 320 INTER PROCESSOR COMMUNICATION PROBLEM WITH TDPC.........................80 321 FATAL HARDWARE ERROR DETECTED BY TDPC ................................................82 328 PERIPHERAL CARD INTER PROCESSOR COMMUNICATION PROBLEM WITH TDPC ..........................................................................................................................................................84 329 PERIPHERAL CARD FATAL HARDWARE ERROR DETECTED BY TDPC.............85 330 PERIPHERAL CARD DIAGNOSTIC FAILED............................................................87 334 NTW RECOVERY REQUIRED....................................................................................88 335 UBEX RECOVERY REQUIRED..................................................................................91 336 PLLH RECOVERY REQUIRED ..................................................................................94 337 SN64 RECOVERY REQUIRED ...................................................................................96 343 SNAP RECOVERY REQUIRED ..................................................................................99 338 SN16 RECOVERY REQUIRED .................................................................................100 16 LINE INTERFACE FAILURE ............................................................................................................ 103 189 LOSS OF SIGNAL......................................................................................................103 190 LOSS OF SIGNAL ON LINK A ..................................................................................104 191 LOSS OF SIGNAL ON LINK B ..................................................................................105 192 AIS ALARM................................................................................................................106 193 AIS ALARM ON LINK A ............................................................................................106 194 AIS ALARM ON LINK B ............................................................................................107 257 L1CTS INTERRUPTION............................................................................................108 266 MPCC HOT LINK FAILED .......................................................................................109 267 TDPC HOT LINK FAILED ........................................................................................110 282 NOTIFIED LOSS OF SIGNAL...................................................................................111 283 NOTIFIED AIS ALARM.............................................................................................112 289 NOTIFIED LOSS OF SIGNAL ON LINK A...............................................................112 290 NOTIFIED LOSS OF SIGNAL ON LINK B...............................................................113 291 NOTIFIED AIS ALARM ON LINK A .........................................................................114 292 NOTIFIED AIS ALARM ON LINK B .........................................................................114 307 NOTIFY PDT ALIGNMENT LOST ............................................................................115 17 LINK FAILURE .................................................................................................................................. 117 068 AP CONNECTION FAILURE....................................................................................117 182 OMAL DISCONNECTED ..........................................................................................118 183 X25 DISCONNECTED...............................................................................................119 184 CBCL DISCONNECTED ...........................................................................................120 185 CBCL DISCONNECTED FOR OVERLOAD.............................................................121 269 LINK DOWN ..............................................................................................................122 271 NSVC CONNECTION FAILURE...............................................................................124 18 LOSS OF SYNCHRONIZATION ....................................................................................................... 126 139 SYNCHRONISM OF PLLH ERROR ..........................................................................126 140 SYNC LINK ERROR...................................................................................................127 141 PLLH VCXO OUT OF NORMAL RANGE.................................................................128 142 SYNCHRONISM FAILED MEASUREMENT.............................................................129 152 SYNE WITHOUT SIGNAL .........................................................................................129 22 POWER SUPPLY FAILURE .............................................................................................................. 131 348 EXTENDED RACK 48V COPY 1 FAILED................................................................132 29 TRANSCEIVER PROBLEM .............................................................................................................. 133 066 NO CALL IN CELL WITHIN A PREDEFINED TIME FRAME.................................133 070 NO CALL IN TRX WITHIN A PREDEFINED TIME FRAME ...................................134 37 DATABASE INCONSISTENCY........................................................................................................ 136 013 TDPC DATABASE NOT CONSISTENT.....................................................................136 018 STATUS MANAGER DEVICE HANDLER AUDIT MISMATCH...............................137 027 DATABASE INCONSISTENCY WARNING ...............................................................138
4 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

028 AP CIRCUIT POOL MISMATCH..............................................................................149 105 UNCOMPATIBLE BSC CONFIGURATION .............................................................150 176 LPDL LINK AUDIT MISMATCH ..............................................................................150 341 DATABASE NOT COMPATIBLE WITH ESUSW ......................................................151 344 TRAU AMR BUT POOLING DISABLED ..................................................................152 38 FILE SYSTEM CALL UNSUCCESSFUL .......................................................................................... 153 004 FILE SYSTEM OPERATION FAILURE ....................................................................153 39 INPUT PARAMETER OUT OF RANGE........................................................................................... 169 025 INPUT PARAMETER OUT OF RANGE WARNING .................................................169 041 INVALID SPECIFIC PROBLEM IN ERROR CALL ..................................................183 042 INVALID OBJECT IDENTIFIER IN ERROR CALL..................................................184 054 AP A-BIS TIMER FAULT ..........................................................................................185 056 AP CELL OVERFLOW ..............................................................................................185 074 AP CHANNEL OVERFLOW......................................................................................186 077 AP CONNECTION OVERFLOW...............................................................................187 079 AP ID2MBIT OVERFLOW ........................................................................................188 087 AP MODE OVERFLOW ............................................................................................188 098 AP SUBCHANNEL OVERFLOW...............................................................................189 099 AP TRX OVERFLOW.................................................................................................189 100 AP TERRESTRIAL TIME SLOT OVERFLOW...........................................................190 104 AP HW CIRCUIT IDENTITY CODE OVERFLOW ...................................................191 275 AP BVC OVERFLOW ................................................................................................192 277 AP PCU OVERFLOW................................................................................................193 279 AP PDT OVERFLOW ................................................................................................193 281 AP PCU TIMER FAULT............................................................................................194 41 INVALID POINTER ........................................................................................................................... 196 023 INVALID POINTER WARNING ................................................................................196 024 INVALID POINTER FULL INITIALIZATION...........................................................201 42 MESSAGE NOT EXPECTED ............................................................................................................ 203 040 UNEXPECTED MESSAGE RECEIVED ERROR ......................................................203 047 RECEIVED CORRUPTED MESSAGE......................................................................232 084 AP MESSAGE LENGTH FAULT...............................................................................238 085 AP MANDATORY ELEMENT FAULT.......................................................................238 086 AP MANDATORY ELEMENT OVERFLOW..............................................................239 088 AP MESSAGE TYPE FAULT.....................................................................................240 094 AP O&M DISCRIMINATOR FAULT.........................................................................240 095 AP OPTIONAL ELEMENT FAULT ...........................................................................241 096 AP OPTIONAL ELEMENT OVERFLOW ..................................................................241 097 AP PROTOCOL DISCRIMINATOR FAULT .............................................................242 177 INVALID ASUB MESSAGE .......................................................................................242 181 INVALID ABIS MESSAGE.........................................................................................243 245 AP TRACE ERROR NOTIFICATION INVALID PARAMETER ................................244 262 INVALID MESSAGE TO PCUC ................................................................................245 305 ABIC INVALID MESSAGE ........................................................................................245 43 MESSAGE NOT INITIALIZED ......................................................................................................... 247 026 MESSAGE NOT INITIALIZED WARNING................................................................247 44 MESSAGE OUT OF SEQUENCE ...................................................................................................... 249 032 MESSAGE OUT OF SEQUENCE WARNING ...........................................................249 45 SYSTEM CALL UNSUCCESSFUL ................................................................................................... 262 002 DATABASE BACKUP FAILED .................................................................................262 003 FUNCTION CALL UNSUCCESSFUL .......................................................................263 029 SYSTEM CALL UNSUCCESSFUL WARNING..........................................................265 030 SYSTEM CALL UNSUCCESSFUL PRIME TASK INIT.............................................302 031 SYSTEM CALL UNSUCCESSFUL FULL INIT .........................................................306 034 COMMAND REJECTED WARNING.........................................................................307 053 INACCESSIBLE DUAM ERROR ...............................................................................311 46 TIMEOUT EXPIRED.......................................................................................................................... 313
A30808-X3247-K240-3-7619 5

Outputs OML:BSC

Base Station Controller

033 TIMEOUT EXPIRED WARNING ..............................................................................313 47 VARIABLE OUT OF RANGE............................................................................................................ 333 022 VARIABLE OUT OF RANGE WARNING..................................................................333 49 COOLING SYSTEM FAILURE ......................................................................................................... 343 125 AIR CONDITIONING EQUIPMENT ALARM...........................................................343 50 EXTERNAL EQUIPMENT FAILURE............................................................................................... 345 134 OPERATOR DEFINED ALARM................................................................................345 51 EXTERNAL POWER SUPPLY FAILURE ........................................................................................ 347 133 MAIN POWER SUPPLY ALARM ..............................................................................347 52 EXTERNAL TRANSMISSION DEVICE FAILURE ......................................................................... 349 130 TRANSMISSION EQUIPMENT ALARM ...................................................................349 56 INTRUSION DETECTED .................................................................................................................. 351 129 INTRUSION DETECTION ALARM...........................................................................351 59 SMOKE DETECTED .......................................................................................................................... 353 128 SMOKE DETECTION ALARM..................................................................................353 64 SYSTEM RESOURCES OVERLOAD ............................................................................................... 355 132 CTR OVERLOAD.......................................................................................................355 188 MSC OVERLOAD DETECTED .................................................................................356 223 AP TRACE TDPC OVERLOAD.................................................................................356 243 BTS OVERLOAD DETECTED ..................................................................................357 249 BSC OVERLOAD DETECTED..................................................................................358 65 BROADCAST CHANNEL FAILURE ................................................................................................ 359 113 BTS NO CBCH AVAILABLE .....................................................................................359 167 BCCH OUTAGE ........................................................................................................361 67 INVALID MESSAGE RECEIVED ..................................................................................................... 362 108 INVALID MESSAGE FROM ABIS/ASUB..................................................................362 109 INVALID MESSAGE TO ABIS/ASUB........................................................................363 263 INVALID MESSAGE FROM PCUC ..........................................................................363 265 INVALID READING MESSAGE................................................................................364 268 BSSGP INVALID MESSAGE .....................................................................................366 346 INVALID MESSAGE FROM PPXL ...........................................................................367 68 INVALID MSU RECEIVED............................................................................................................... 369 106 SCCP INVALID MSU RECEIVED ............................................................................369 168 INVALID MSU RECEIVED .......................................................................................370 69 LAPD LINK PROTOCOL FAILURE ................................................................................................. 372 174 LPDL LINK UNSTABLE............................................................................................372 175 LPDL LINK TRANSITION .........................................................................................373 331 BTSM UNSTABLE ALIGNMENT ..............................................................................374 71 REMOTE ALARM INDICATOR ....................................................................................................... 376 112 PCM UNAVAILABLE REMOTE PROBLEMS...........................................................376 204 REMOTE ALARM ......................................................................................................377 205 REMOTE ALARM ON LINK A ..................................................................................378 206 REMOTE ALARM ON LINK B ..................................................................................378 286 NOTIFIED REMOTE ALARM ...................................................................................379 297 NOTIFIED REMOTE ALARM ON LINK A ...............................................................380 298 NOTIFIED REMOTE ALARM ON LINK B ...............................................................381 72 ROUTING FAILURE .......................................................................................................................... 382 107 ROUTING FAILURE .................................................................................................382 73 SS7 PROTOCOL FAILURE ............................................................................................................... 384 169 SS7 LINK ACTIVATION FAILURE ...........................................................................384 219 UNAVAILABLE SS7 LINKS THRESHOLD MINOR..................................................385 221 UNAVAILABLE SS7 LINKS THRESHOLD MAJOR .................................................385 224 UNAVAILABLE SS7 LINKS THRESHOLD CRITICAL .............................................386 252 SS7L FAILURE ..........................................................................................................386 74 TRANSMISSION ERROR .................................................................................................................. 388 059 REMOTE LOWER BER THRESHOLD EXCEEDED ................................................388 201 HIGHER BER THRESHOLD EXCEEDED ...............................................................389
6 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

202 HIGHER BER THRESHOLD EXCEEDED ON LINK A............................................390 203 HIGHER BER THRESHOLD EXCEEDED ON LINK B............................................390 210 LOWER BER THRESHOLD EXCEEDED ON LINK A .............................................391 211 LOWER BER THRESHOLD EXCEEDED ON LINK B .............................................392 287 NOTIFIED HIGHER BER THRESHOLD EXCEEDED ............................................393 288 NOTIFIED LOWER BER THRESHOLD EXCEEDED..............................................393 299 NOTIFIED HIGHER BER THRESHOLD EXCEEDED ON LINK A ........................394 300 NOTIFIED HIGHER BER THRESHOLD EXCEEDED ON LINK B ........................395 301 NOTIFIED LOWER BER THRESHOLD EXCEEDED ON LINK A ..........................395 302 NOTIFIED LOWER BER THRESHOLD EXCEEDED ON LINK B ..........................396 4 ISO, PROBABLE CAUSES ...................................................................................................................397 07 CONFIGURATION OR CUSTOMIZATION ERROR....................................................................... 397 016 BTSM SOFTWARE VERSION NOT DEFINED.........................................................397 017 TRAU SOFTWARE VERSION NOT DEFINED.........................................................398 055 AP BTS IDENTIFIER FAULT ...................................................................................398 057 AP CELL NOT CONFIGURED .................................................................................399 058 AP CHANNEL NOT CONFIGURED.........................................................................400 067 AP TRX NOT CONFIGURED....................................................................................400 072 AP AIR TIMER FAULT..............................................................................................401 073 AP CELL GLOBAL IDENTIFICATION NOT PRESENT ..........................................401 075 AP CELL IDENTIFICATION NOT PRESENT ..........................................................402 081 AP LOCATION AREA CODE CELL IDENTIFICATION NOT PRESENT................403 082 AP LOCATION AREA CODE NOT PRESENT..........................................................403 083 AP LOCATION AREA IDENTIFICATION NOT PRESENT ......................................404 089 AP NO ADJACENT CELL .........................................................................................404 090 AP NO CELL PRESENT ............................................................................................405 093 AP NO TERRESTRIAL CHANNEL............................................................................405 103 AP HW CIRCUIT IDENTITY CODE NOT CONFIGURED ......................................406 110 UNEXPECTED LPDL ESTABLISHED .....................................................................407 135 AP BTS WITHOUT ALL BBSIG44 CARDS ...............................................................407 157 INVALID TYPE OF SN ..............................................................................................408 160 INVALID TYPE OF PLLH .........................................................................................409 162 INVALID TYPE OF LICD..........................................................................................409 270 CONFIGURATION MISMATCH ...............................................................................410 276 AP BVC NOT CONFIGURED ...................................................................................411 278 AP PCU NOT CONFIGURED...................................................................................412 280 AP PDT NOT CONFIGURED ...................................................................................412 306 AP ROUTING AREA CODE NOT PRESENT............................................................413 08 CONGESTION .................................................................................................................................... 415 043 START THROTTLING ERROR..................................................................................415 273 OVERFLOW OF COMMANDS TABLES...................................................................416 09 CORRUPT DATA ............................................................................................................................... 418 147 INVALID MESSAGE TO RTE....................................................................................418 005 CHECK ON FILE CONTENTS FAILED ...................................................................419 264 INVALID ACCESS TO DATA ....................................................................................420 304 INVALID MESSAGE LENGTH..................................................................................422 308 INVALID DESTINATION MAILBOX ........................................................................429 333 MEMORY BUFFER CORRUPTED...........................................................................432 345 INVALID DUAM INDEX ...........................................................................................436 14 ENCLOSURE DOOR OPEN............................................................................................................... 438 127 ENCLOSURE DOOR OPEN ALARM........................................................................438 17 FILE ERROR....................................................................................................................................... 440 170 ERROR IN PREPAIRING FILE.................................................................................440 216 FILE TOO LONG WARNING ....................................................................................441 18 FIRE DETECTED ............................................................................................................................... 443 126 FIRE DETECTED ALARM ........................................................................................443
A30808-X3247-K240-3-7619 7

Outputs OML:BSC

Base Station Controller

22 HUMIDITY UNACCEPTABLE ......................................................................................................... 445 124 HUMIDITY UNACCEPTABLE ALARM ....................................................................445 28 LOSS OF FRAME ............................................................................................................................... 447 195 LOSS OF FRAME ALIGNMENT ...............................................................................447 196 LOSS OF FRAME ALIGNMENT ON LINK A ...........................................................448 197 LOSS OF FRAME ALIGNMENT ON LINK B ...........................................................449 198 LOSS OF CRC ALIGNMENT ....................................................................................450 199 LOSS OF CRC ALIGNMENT ON LINK A.................................................................451 200 LOSS OF CRC ALIGNMENT ON LINK B.................................................................451 208 SLIP ALARM ON LINK A ..........................................................................................452 209 SLIP ALARM ON LINK B ..........................................................................................453 284 NOTIFIED LOSS OF FRAME ALIGNMENT ............................................................454 285 NOTIFIED LOSS OF CRC ALIGNMENT .................................................................454 293 NOTIFIED LOSS OF FRAME ALIGNMENT ON LINK A ........................................455 294 NOTIFIED LOSS OF FRAME ALIGNMENT ON LINK B ........................................456 295 NOTIFIED LOSS OF CRC ALIGNMENT ON LINK A..............................................456 296 NOTIFIED LOSS OF CRC ALIGNMENT ON LINK B..............................................457 32 OUT OF MEMORY ............................................................................................................................ 458 039 FULL INIT REQUESTED..........................................................................................458 045 MEMORY NOT AVAILABLE .....................................................................................459 048 ERROR MESSAGES DISCARDED............................................................................469 049 MEMORY OVERFLOW .............................................................................................470 050 DYNAMIC MEMORY POOL OVERFLOW ...............................................................472 060 AP MEMORY MESSAGE FAULT..............................................................................473 091 AP NO MEMORY.......................................................................................................473 114 MEMT DUAM OVERFLOW......................................................................................475 232 DYNAMIC MEMORY POOL OVERFLOW UPPINIT ...............................................476 311 DYNAMIC MEMORY POOL OVERFLOW LOWINIT...............................................477 312 MEMORY OVERFLOW LOWINIT ............................................................................478 313 MEMORY OVERFLOW UPPINIT.............................................................................478 46 SOFTWARE ERROR.......................................................................................................................... 480 001 COMMAND FULL INITIALIZATION REQUIRED...................................................480 009 FILE TRANSFER ABORTED BY NETWORK ELEMENT.........................................482 010 FILE TRANSFER FAILED ON NETWORK ELEMENT ............................................484 011 FILE TRANSFER REFUSED BY NETWORK ELEMENT .........................................485 012 STATUS MANAGER DATABASE NOT ALIGNED....................................................486 015 GENERIC SOFTWARE ERROR ................................................................................487 019 UNABLE TO RUN TEST............................................................................................491 020 WRONG CONNECTION REQUEST .........................................................................492 021 CONNECTION REQUEST REJECTED ....................................................................493 035 MAILBOX NOT ALLOCATED ERROR .....................................................................495 036 UNSUCCESSFUL RESPONSE FROM STATUS MANAGER ERROR ......................497 037 SPARE TO PRIME INITIALIZATION .......................................................................498 038 PRIME TO FULL INITIALIZATION .........................................................................499 046 MESSAGE DISCARDED ...........................................................................................500 051 DELETED CURRENT TASK .....................................................................................504 052 SYSTEM RESTART ....................................................................................................506 069 AP ERROR REPORT .................................................................................................506 071 AP ERROR INDICATION..........................................................................................507 076 AP CONNECTION NOT ACTIVE..............................................................................508 078 AP CONNECTION STATUS FAULT .........................................................................509 080 AP INCONSISTENCY ................................................................................................509 092 AP NO RADIO CHANNEL ........................................................................................512 101 AP NOT UPDATED...................................................................................................513 111 AP CONFUSION .......................................................................................................513 115 MEMT SEMAPHORE LOCKED ...............................................................................514 131 CTR GENERIC MESSAGE ........................................................................................516
8 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

136 INVALID MESSAGE TO PSOS .................................................................................517 137 INVALID SEND MESSAGE IN RTE..........................................................................517 138 INVALID RECEIVE MESSAGE IN RTE....................................................................518 148 PSE ERROR ...............................................................................................................518 149 INVALID SEND MESSAGE.......................................................................................519 150 INVALID STREAM OUTPUT ....................................................................................520 154 INVALID CLOSE .......................................................................................................521 178 TRAU ALIGNMENT FAILED....................................................................................521 179 BTSM FAILED ALIGNMENT....................................................................................523 220 BAD SOFTWARE ON PERIPHERAL CARD ............................................................524 222 AP TRACE ERROR NOTIFICATION ........................................................................528 229 BRING UP ACTIVE REQUESTED............................................................................529 240 REPORT INCOMPLETED ........................................................................................529 248 PPXX DEVICE HANDLER INTER PROCESSOR COMMUNICATION SEMAPHORE LOCKED...................................................................................................................................................532 250 IMSI TRACE GENERIC MESSAGE ..........................................................................533 255 FULL INITIALIZATION OCCURRED ......................................................................534 256 BRING UP INITIALIZATION OCCURRED ..............................................................535 274 PCU ALIGNMENT FAILURE ...................................................................................535 303 NOTIFIED GBIC CONFIGURATION MISMATCH..................................................536 309 AP NOFREE PDT......................................................................................................537 310 NOTIFY GPRS PREHEMPTION...............................................................................538 314 DELETED CURRENT TASK LOWINIT ....................................................................539 315 DELETED CURRENT TASK UPPINIT .....................................................................539 322 SDSM SM DATABASE NOT ALIGNED ....................................................................540 323 SDSM DATABASE NOT ALIGNED...........................................................................541 324 ANOTHER OPERATION IS IN PROGRESS .............................................................541 326 DOWNLOAD FAILED...............................................................................................542 327 FILE UNUSABLE ......................................................................................................542 332 WRONG PROCESSOR COPY ...................................................................................543 339 FILE MISSING...........................................................................................................544 319 INVALID STATUS WARNING ...................................................................................544 340 BUFFER NOT FOUND .............................................................................................546 47 SOFTWARE PROGRAM ABNORMALLY TERMINATED ............................................................ 547 014 TASK ABORTED BY SYSTEM...................................................................................547 238 UNABLE TO INITIALIZE ..........................................................................................550 246 AP TRACE ERROR NOTIFICATION ABNORMAL TERMINATION........................550 49 STORAGE CAPACITY ERROR ........................................................................................................ 552 006 INTERWORKING COMMAND TABLE ERROR .......................................................552 50 TEMPERATURE UNACCEPTABLE ................................................................................................ 554 123 TEMPERATURE UNACCEPTABLE ALARM ...........................................................554 56 UNDERLYING RESOURCE NOT AVAILABLE ............................................................................. 556 008 FILE ALREADY IN USE............................................................................................556 061 AP NO CHANNEL PRESENT....................................................................................557 062 AP NO FREE CHANNELS.........................................................................................558 063 AP NO FREE CONNECTIONS..................................................................................558 064 AP NO FREE INSTANCE ..........................................................................................559 065 AP NO HANDOVER REFERENCE...........................................................................560 102 UNAVAILABLE RADIO SIGNALLING CHANNELS THRESHOLD MINOR ...........560 118 UNAVAILABLE RADIO SIGNALLING CHANNELS THRESHOLD MAJOR ...........562 156 UNAVAILABLE RADIO SIGNALLING CHANNELS THRESHOLD CRITICAL.......563 164 UNAVAILABLE ABIS TCH THRESHOLD MINOR...................................................564 165 UNAVAILABLE ABIS TCH THRESHOLD MAJOR ..................................................566 166 UNAVAILABLE ABIS TCH THRESHOLD CRITICAL ..............................................567 225 UNAVAILABLE AINT TCH THRESHOLD MINOR ..................................................569 226 UNAVAILABLE AINT TCH THRESHOLD MAJOR ..................................................569 227 UNAVAILABLE AINT TCH THRESHOLD CRITICAL..............................................570
A30808-X3247-K240-3-7619 9

Outputs OML:BSC

Base Station Controller

230 MPCC OUTAGE........................................................................................................570 231 TDPC OUTAGE.........................................................................................................571 233 MEMT OUTAGE........................................................................................................572 234 DISK OUTAGE ..........................................................................................................574 235 IXLT OUTAGE...........................................................................................................574 236 NTW OUTAGE...........................................................................................................575 241 EPWR OUTAGE ........................................................................................................575 242 PPCC OUTAGE.........................................................................................................576 244 AP TRACE ERROR NOTIFICATION UNAVAILABILITY.........................................576 247 FUNCTIONALITY LOST ...........................................................................................577 251 SYNE OUTAGE..........................................................................................................580 253 SS7S FAILURE ..........................................................................................................580 258 OMAL OUTAGE ........................................................................................................581 259 CBCL OUTAGE .........................................................................................................581 260 X25 OUTAGE ............................................................................................................582 57 VERSION MISMATCH...................................................................................................................... 583 007 SOFTWARE NOT ALIGNED .....................................................................................583 228 IXLT CARD RESET ...................................................................................................585 ANNEX A ........................................................................................................................................................586 ANNEX B........................................................................................................................................................589 ANNEX C .......................................................................................................................................................604 ANNEX D .......................................................................................................................................................606 ANNEX E........................................................................................................................................................622 ANNEX F........................................................................................................................................................647 SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID:
10

001 MEMT CONFIGURATION SWITCHED BY SYSTEM ........................................................ 647 002 EPWR NOT REACHABLE ........................................................................................... 649 003 NMI SYSTEM INFO.................................................................................................... 650 004 TDPC LOG BASE DATA ............................................................................................ 652 005 TDPC LOG TRACE DATA .......................................................................................... 653 006 TDPC LOG EXCEPTION ............................................................................................. 654 007 TDPC LOG OS DATA ............................................................................................... 655 008 TDPC LOG MEMT DATA .......................................................................................... 656 009 TDPC LOG FW DATA............................................................................................... 657 010 TDPC ACTIVE SWITCHED BY SYSTEM ...................................................................... 660 011 TDPC ACTIVE RESTARTED BY SYSTEM .................................................................... 662 012 UNABLE TO INITIALIZE TDPC SW ............................................................................ 664 013 UNABLE TO INITIALIZE CARD .................................................................................... 666 014 FAILED LOAD SW PROCEDURE ................................................................................. 667 015 FAILED LOAD PATCH PROCEDURE ............................................................................ 669 016 FAILED LOAD DATABASE PROCEDURE ...................................................................... 671 017 RETRY TO SCHEDULE LOAD PROCEDURE .................................................................. 672 018 CORRUPTED SW ON CARD ........................................................................................ 673 020 INTRA PROCESSOR LINK TRACE ................................................................................ 675 021 BAD SW VERSION ON BOARD` ................................................................................. 676 022 MPCC LOG INTERNAL REGISTERS ............................................................................ 678 023 MPCC LOG PCS 0.................................................................................................... 679 024 MPCC LOG PCS 1.................................................................................................... 680 025 MEMT CONTENTS LOST........................................................................................... 681 026 AUDIT MESSAGE OUT OF SEQUENCE......................................................................... 683 027 NO RESPONSE TO MESSAGE AUDIT ........................................................................... 684 028 TDPC CONTROL LOST .............................................................................................. 685
A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID:

029 RETRY TO ALIGN MEMT RAM ................................................................................. 686 030 NMI OS TRAP ........................................................................................................... 687 031 BTS NO BCCH AVAILABLE INFO ............................................................................. 688 032 BTS FAILED HOPPING SYSTEM INFO ......................................................................... 691 033 BTS NO CBCH AVAILABLE INFO ............................................................................. 694 034 BTS NO SDCCH AVAILABLE INFO ........................................................................... 697 035 BTS NO TCH AVAILABLE INFO ................................................................................ 700 036 BTSM FAILED ALIGNMENT INFO .............................................................................. 703 037 BTSM ALIGNMENT REQUIRED INFO ......................................................................... 705 038 BTS NO BCCH AVAILABLE 21 INFO ........................................................................ 707 039 TRAU SW ALIGNMENT INFO ................................................................................... 710 040 TRAU UNSTABLE BEHAVIOR INFO ........................................................................... 712 041 POWER KEYLOCK SWITCH ON.................................................................................. 714 042 POWER KEYLOCK SWITCH OFF ................................................................................ 715 043 DK40 SYSTEM INFO.................................................................................................. 716 045 BCCH OUTAGE INFO ................................................................................................ 719 046 UNCORRECT CARD SOFTWARE STATUS .................................................................... 722 047 HARDWARE PROBLEM IN SOFTWARE CHECK ............................................................ 728 048 CARD SOFTWARE TIME OUT ..................................................................................... 732 049 FULL INITIALIZATION REQUESTED FROM TDPC ........................................................ 735 050 UNEXPECTED MASKED NMI ..................................................................................... 737 051 STATUS MANAGER DATA ALIGNMENT ....................................................................... 739 052 TRAU ALIGNMENT REQUIRED INFO ......................................................................... 742 053 STATUS MANAGER TIMER QUEUE REFRESH ............................................................... 744 054 BTSM NE IDENTIFICATION FAILED INFO .................................................................. 745 055 TRAU NE IDENTIFICATION FAILED INFO .................................................................. 746 056 ABIS CHANNEL MISMATCH...................................................................................... 747 057 X25A POSSIBLY OUT OF SERVICE............................................................................. 748 058 ABIS ASUB NACK ...................................................................................................... 749 059 HOT LINK INFO ......................................................................................................... 750 060 NO RESPONSE FROM MEMORY ALIGN SERVER ......................................................... 752 061 PERIPHERAL SOFTWARE RESTARTED ........................................................................ 753 062 PLLH RESTARTED .................................................................................................... 755 063 IXLT SYSTEM INFO .................................................................................................... 757 064 NSVC UNAVAILABLE INFO................................................................................ 761 065 PPCU FIRMWARE TEST FAILED........................................................................ 763 066 BVC CONNECTION FAILURE INFO................................................................... 765 067 PCU ALIGNMENT REQUIRED INFO .................................................................. 767 068 ABIC FATAL HW PROBLEM ............................................................................... 772 069 ABIC HW PROBLEM DIAGNOSTIC REQUIRED............................................... 773 072 GBIC HW PROBLEM DIAGNOSTIC REQUIRED .......................................................... 774 073 GBIC SW PROBLEM ................................................................................................ 786 075 PCUC HW PROBLEM DIAGNOSTIC REQUIRED.............................................. 795 076 PCUC SW PROBLEM............................................................................................. 804 077 GBIC NS-PROTOCOL FAILURE .......................................................................... 810 078 GBIC NS-PROTOCOL EVENT .............................................................................. 812 079 GBIC NS-CONGESTION STATUS CHANGE ...................................................... 814 080 PCU ALIGNMENT FAILURE INFO...................................................................... 816 081 GBIC IPC PROBLEM ............................................................................................. 818 082 PPCU FW DOWNLOAD IN PROGRESS .............................................................. 820 083 PPLD/PPCC FIRMWARE TEST FAILURE........................................................... 821 084 PPCU HW EXCEPTION ......................................................................................... 823 085 PSOS SYSTEM CALL FAILURE.......................................................................... 825 086 TASKIFTABLE UPDATE FAILURE..................................................................... 830 087 INVALID PRIORITY.............................................................................................. 832 088 INVALID STATUS ................................................................................................. 834
11

A30808-X3247-K240-3-7619

Outputs OML:BSC

Base Station Controller

SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID: SYSINFO_ID:

089 PSOS MESSAGE INVALID FIELD ....................................................................... 836 090 PSOS START MODE FAILURE ............................................................................ 838 091 RTE+PS INVALID SCHEDULING PHASE .......................................................... 840 092 PSOSTASKTABLE UPDATE FAILURE............................................................... 841 093 MPCC DB LOAD START....................................................................................... 843 094 TDPC DB ALIGNMENT START........................................................................... 844 095 MPCC DB LOAD END ........................................................................................... 845 096 TDPC DB ALIGNMENT END ............................................................................... 846 097 MPCC DB LOAD FAILURE................................................................................... 847 098 TDPC DB ALIGNMENT FAILURE....................................................................... 849 099 DB BACKUP START ............................................................................................. 851 100 DB BACKUP END.................................................................................................. 852 101 DB BACKUP FAILURE ......................................................................................... 853 102 DELETE RTE TASK FAILURE ............................................................................. 854 103 LPDL LINK UNSTABLE........................................................................................ 855 104 BTSM FAST ALIGNMENT INFO ......................................................................... 856 105 NETWORK SYSTEM INFO ....................................................................................... 858 106 PLLH SYSTEM INFO ................................................................................................. 859 107 UBEX SYSTEM INFO ................................................................................................ 860 108 SN64 SYSTEM INFO .................................................................................................. 861 109 SN16 SYSTEM INFO .................................................................................................. 862 110 XXGP AUDIT NO ANSWER ................................................................................. 863 112 TRAU ALIGNMENT FAILED INFO ..................................................................... 864 113 MIT_ALREADY_IN_PROGRESS ......................................................................... 866 114 THROTTLING CONDITION STARTED ........................................................................... 867 115 THROTTLING CONDITION ENDED............................................................................... 868 116 TRAU-AMR BUT POOLING DISABLED INFO............................................................. 869 117 DISK SYSTEM INFO .................................................................................................. 871 118 CHANGE VERSION INFO..................................................................................... 874 119 PPXU/PPXL FIRMAWARE TEST FAILURE ....................................................... 876 120 CHECKSUM_PID_FAILURE................................................................................. 877 130 SNAP SYSTEM INFO ................................................................................................. 878 131 PPXL UNSUCCESSFUL LINK CONFIGURATION .......................................................... 879 132 PPXL/PPXU SYSTEM INFO ...................................................................................... 881 133 O-LINK OVERLOAD DETECTED........................................................................ 898 134 O-LINK OVERLOAD CEASED ............................................................................. 899 135 INVALID MESSAGE OF ABIS/ASUB INFO........................................................ 900 136 LLP LINK UP INFO ..................................................................................................... 902 137 LLP LINK DOWN INFO ............................................................................................... 904 140 STANDARD LOGGING SUSPENDED ................................................................. 906 141 STANDARD LOGGING RESUMED ..................................................................... 907 142 MIT REQUEST POSTPONED ............................................................................... 908

ANNEX G .......................................................................................................................................................909 SPECIFIC PROBLEMS INDEX.................................................................................................................910

12

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Introduction

This output manual is just a listing of all possible system messages. Output manuals can not substitute or replace maintenance manuals and are only intended for the support of experienced personnel when performing specialized fault clearance tasks. The goal of this manual is to describe all alarms and System Informations that the SBS/BSC system can generate. An example of one BSC Failure Event Report printout from Local Terminal is shown below. It is composed of the following parts: LIST OF ALL BSC ERROR DESCRIPTIONS; ANNEX A: list of all BSC objects mnemonics; ANNEX B: list of all alarm originators (software modules); ANNEX C: DBA sw area specific originators; ANNEX D: LEVEL 3 RADIO sw area specific originators; ANNEX E: list of all RTE System Information Reports; ANNEX F: list of all System Information Reports; ANNEX G: LIST OF ALL THE PROPOSED REPAIR ACTIONS.

Alarms Overview: An alarm occurrence appears at the Local Terminal with the following layout:

ALARM_REPORTING -> SYSTEM_BROADCAST 16:00:03 17/02/2000 21:34:24 17/02/2000 *** INFORMATION *** FAILURE EVENT REPORT: NAME = DISK:1 Event Type = Equipment Failure Event Event Time = 17/01/2002 16:00:00 Probable Cause = Disk Problem Specific Problems = 181-DISK not Aligned Severity = Major Trend Indication = More Severe Notification Identifier = 05 Proposed Repair Actions = 1 NoAction Additional Text = Null String Originator = 4305 Additional Words = H'003c H'0335 H'0000 H'0000 H'0000 H'0000 H'0000 H'0000 H'0000 H'0000 H'0000 H'0000 H'0000 H'0000 H'0000 Software Version = 02-06-02-01-00-00_20-05-03

Every different Probable Causes of a Failure Event Report output from Local Terminal is related, at least, with one page of Probable Cause description in this manual. A Probable Cause description in the manual is reported as follows (please refer to the following example):
A30808-X3247-K240-3-7619 13

Outputs OML:BSC

Base Station Controller

DISK PROBLEM
FAILURE EVENT REPORT: NAME = Probable cause = Specific Problems = Event Type = Event Time = Severity = Trend Indication = Notification Identifier = Correlated Notification Identifier = Related MO = Proposed Repair Actions = Additional Text = Originator = Additional Words = aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo Software Version = <R.T.D.> <R.T.D.> Disk Problem <see legend> <see legend> <R.T.D.> <see legend> <R.T.D.> <R.T.D.> <displayed only during Alarm Alignment> <R.T.D.> <R.T.D.> <see legend> <R.T.D.> <see legend>

Legend:
Specific Problems = 172 DISK NOT ALIGNED Event Type = EQUIPMENT FAILURE EVENT Severity = MAJOR Proposed Repair Actions = 1 NO ACTION

Originator = 4305 MDH40IOSC


We are trying to put a disk into service after a Status Manager request (ENABLE/UNLOCK) and it must be re-aligned.
Aaaa Bbbb Cccc Dddd Eeee Ffff Gggg Hhhh Iiii Jjjj Kkkk Llll Mmmm Nnnn Oooo = = = = = = = = = = = = = = = Module that generates the error Source code line of the module that generates the error not used not used not used not used not used not used not used not used not used not used not used not used not used

14

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Failure Event description example Every field, that appears in the previous example, is explained below: NAME: <object mnemonic + object address> A list and a short description of possible mnemonics is reported in ANNEX A. Note that the mnemonic is followed by a structured numbering (address) that univocally identifies an object in the BSC (example:CHAN-0-1-1-3) Probable Cause It is an abbreviated sentence that describes the probable cause of the error. Specific Problem This Failure Event attribute provides further refinement to the Probable Cause attribute. This manual must be consulted only if the BSC subsystem id is reported: in case BTSE or TRAUE is reported, please refer to the related error manuals. Event Type According to CCITT X.733, the following Event Types can be reported: COMMUNICATION FAILURE QUALITY OF SERVICE FAILURE PROCESSING FAILURE EQUIPMENT FAILURE ENVIRONMENTAL FAILURE Event Time This attribute identifies the time of detection of the fault. Severity According to CCITT X.733 the following severities can be reported -when a Failure Event occurs: INDETERMINATE (not used in our system) CRITICAL MAJOR MINOR WARNING -when an Failure Event ceases: CLEARED In case of error ceased, please note that the message part that follows the Severity field is not printed by the Local Terminal. For each alarm the severity is fixed except for all the alarms that put in DISABLED state the related object instance or the Functionality Lost alarm: for these cases, starting from BR4.5, the Severity attribute in this manual is the Alarm Reporting database default severity level. Trend Indication The following Trend Indications can be reported: RC/LMT NotApplicable NoChange LessSevere
A30808-X3247-K240-3-7619 15

Outputs OML:BSC

Base Station Controller

LessSevere-noChange MoreSevere The "NotApplicable" trend indication is printed if the associated severity for the object in question is INDETERMINATE or WARNING. The "NoChange" trend indication is printed if the associated severity for the object in question isn't changed from the severity of those associated to previously reported Failure Events relevant the same object and still active (i.e. no related error ceased message was generated). The "LessSevere" trend indication is printed if the associated severity for the object in question is less severe of the severity of those associated to previously reported Failure Events relevant the same object and still active (i.e. no related error ceased message was generated). The "LessSevere-noChange" trend indication is printed if the associated severity for the object in question is less severe or of equal severity of those associated to previously reported Failure Events relevant the same object and still active (i.e. no related error ceased message was generated). The "MoreSevere" trend indication is printed if the associated severity for the object in question is more severe of those associated to previously reported Failure Events relevant the same object and still active (i.e. no related error ceased message was generated). Notification Identifier This attribute identifies unambiguously the Failure Event. Correlated Notification This attribute identifies the notification to which this Failure Event is considered to be correlated. Since the Failure Event Reports are father event for the Notification Identifier correlations, the Correlated Notification information are shown only for the Failure Event Report output during an Alarm Alignment (RC) or a Get Pending Alarm Command (LMT). Proposed Repair Action This attribute identifies the repair action suggested to the operator for the fault resolution. The Annex G presents a list of all the Proposed Repair Actions used. Note that the string of PRA used for each Specific Problem is a short version of the original string that can be found in the Annex G. Additional Text For the alarms generated by the ENVA objects, the operator shall be able to define his own alarm text and also to define the severity associated to each ENVA objects instance indipendent from the alarm text. The Additional Text string defined by the operator represents a description of the environmental event. This field is always present in a Failure Event Report, but is meaningful only for the ENVIRONMENTAL Failure Events: in all other type of failure events is output as Null String. Originator It is an integer number that identifies the software module originating the Failure Event. A list of possible originators is shown in Annex B. Additional Words aaaa oooo are hex values that are helpful for a detailed description of the error. This part is of particular usefulness for the software designer to analyse the error cause and so to take proper actions to solve the problem. For each originator, under the Legend part of the Failure Event description, the following elements are reported: Software Version Its the BSC software version files (if we are on BSC Local Terminal).

16

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

System Information overview: This type of information (SIR) is introduced in the BSC system to simply help the developers to a better comprehension of a software behaviour or to trace the events associated to a specific software behaviour: this is the reason why the System Info Report (SIR) must be NOT considered on the same level of a Failure Event Report (FER). The System Info Report (SIR) is introduced as a developer oriented event. In some few special cases a SIR is associated to a FER as additional information to what already notified by the FER itself: in this case it's the FER that the customer must take care, while the associated SIR is a collection of information useful only for the developer of the sw area involved to better understand the problem arises with the FER. An example of one System Information report from Local Terminal is shown below:

BSC -> SYSTEM_BROADCAST 20:57:53 10/10/2000 *** INFORMATION *** SystemInfoReport: name = MEMT:1 informationIdentifier = Memt Configuration Switched by System originator = 4605 additionalInfo Info = H`11F Info = H`1A Info = H`1 Info = H`3000 Info = H`3200 Info = H`2D00 Info = H`0000 Info = H`0000 Info = H`0000 Info = H`0000 Info = H`0000 Info = H`0000 Info = H`0000 Info = H`0000 Info = H`0000 Info = H`0000 Info = H`0000 Info = H`0000 Info = H`0000 Info = H`0000 Info = H`0000 Info = H`0000 Info = H`0000 Info = H`0000 Info = H`0000 Info = H`0000 Info = H`0000 Info = H`0000 Info = H`0000 Info = H`0000 Info = H`0000 Info = H`0000 neSoftwareVersion = "02-06-02-01-00-00_20-05-03"

A30808-X3247-K240-3-7619

17

Outputs OML:BSC

Base Station Controller

The System Information Report in the manual (see Annex E) is reported as follows (please refer to the following example):

SYSINFO_ID: 1 Memt Configuration Switched by System


SYSTEM INFO REPORT: Originator: Additional Info : 1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32 <RUN TIME DETERMINATED> XXXX

Legend: Case of XXXX = 4605 MDHPRININ sysinfo description : This error is issued during the initialization phase when MPCC card could not reach TDPC card using the active memt, that is not failed, but using the other one. In this case the MEMT complex configuration is switched automatically by MPCC without error notification and without operator intervention. 1= Line in the code where the system info is issued. 2= Initialization level. 3= Number of performed attempts to initializa TDPC. 4= Old memt complex configuration before the init started. 5= New memt complex configuration as chosen by MPCC card. 6= Not used 7= Not used 8= Not used 9= Not used 10 = Not used 11 = Not used 12 = Not used 13 = Not used 14 = Not used 15 = Not used 16 = Not used 17 = Not used 18 = Not used 19 = Not used 20 = Not used 21 = Not used 22 = Not used 23 = Not used 24 = Not used 25 = Not used 26 = Not used 27 = Not used 28 = Not used 29 = Not used 30 = Not used 31 = Not used 32 = Not used

System Information description example Info Id It is the second part of the System Information reported by the Local Terminal, but is the first element reported in the manual since it is the key element to determine the associated description. This manual must be consulted only if the BSC subsystem id is reported: in case BTSE or TRAUE is reported,
18 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

please refer to the related error manuals. System Information Report: name = <mnemonic-address> A list and a short description of possible mnemonics is reported in ANNEX A. Note that the mnemonic is followed by a structured numbering (address) that univocally identifies an object in the BSC (example: CHAN-0-1-3). Originator It is an integer number that identifies the software module originating the System Information. A list of possible originators is shown in ANNEX B. Additional Info 1 32 are hex values that are helpful for a detailed description fo the system information. This part is particular usefulness for the software designer to analyse the system info. System Info description For each originator, under the Legend part of the System Information Report is reported this element, that is a concise description of the probable cause of the system info output. Besides each used element of the Additional Info is explained. NeSoftwareVersion Its the Software Version of the BSC files (if we are on BSC Local Terminal). IMPORTANT NOTE: The System Info Reports on MPCC have always the Software Version, while the same Reports on TDPC cannot have the Software Version information, because on TDPC processor this information is not available. The System Info Reports coming from TDPC can be recognized by looking the "originator" field.

A30808-X3247-K240-3-7619

19

Outputs OML:BSC

Base Station Controller

GSM, PROBABLE CAUSES

06 CLOCK SYNCHRONISATION PROBLEM


FAILURE EVENT REPORT: NAME = Probable cause = Specific Problems = Event Type = Event Time = Severity = Trend Indication = Notification Identifier = Correlated Notification Identifier = Related MO = Proposed Repair Actions = Additional Text = Originator = Additional Words =
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo <R.T.D.>

<R.T.D.> <R.T.D.> Clock Synchronisation Problem <see legend> <see legend> <R.T.D.> <see legend> <R.T.D.> <R.T.D.> <displayed only during Alarm Alignment> <R.T.D.> <R.T.D.> <see legend> <R.T.D.> <see legend>

Software Version =

Legend:

##StartSpecProbl## Specific Problems = 153 PLLH NOT STABLE Event Type = EQUIPMENT FAILURE EVENT Severity = WARNING Proposed Repair Actions = 5 SEE THE PROPOSED ACTION IN THE MANUAL

Originator = 4205 MDHNWDCAL The PLLH slave is not able to work locked to the master PLLH, probably because it is cold: this can happen either because the power supply has been switched on since too little time, or because the PLLH has just been plugged in. This error can also occur if the master PLLH is locked to a bad external source (SYNC or SYNE), or if the VCXO oscillator is faulted. The network object will be put disabled soon, if the problem is on the PLLH.
aaaa = bbbb = (developer oriented) code source line where error occurred value of the pllh alarm register. The following codes can be logically OR-ed: 0x1 (bit 0): If this bit is set, the PLLH is distributing its own clock signal to the peripheral

20

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
cards, otherwise it is distributing the clocks of the other PLLH 0x2 (bit 1): the input external synchronism is missing 0x4 (bit 2): the output clock is missing 0x8 (bit 3): the input external source to be measured is missing 0x10 (bit 4): the PLLH is not synchronized with the other PLLH 0x20 (bit 5): address parity alarm on UBEX bus 0x40 (bit 6): data parity alarm on UBEX bus 0x80 (bit 7): watch dog alarm on the local processor FW code of the PLLH indicating the cause of the last occurred interrupt: 0x1=>VCXO voltage out of range 0x2=>PLL unlocked 0x3=>Excessive jitter on synchronization source 0x4=>absence of the synchronization source 0x5=>last command from MPCC has not been understood 0x6=>VCXO voltage in the pre-alarm range 0x7=>interruption of the synchronization source 0x8=>eprom checksum failure 0x9=>fault on the DAC or on the ADC 0xA=>fault in the phase comparator 0xD=>CIOA fault (only PLLH V2) TUNE word of master PLLH DAC word of master PLLH TUNE word of slave PLLH (if standby network is disabled, this value can be meaningless) DAC word of slave PLLH (if standby network is disabled, this value can be meaningless) Edition of the 2 PLLH (0=659-7/0035x <x=B,C>, 1=PLLH V1, 2=PLLH V2). In the lower byte, there is the edition of this PLLH, in the higher byte the edition of other copy. Type of active synchronization source: 44(0x2C): SYNC; 45(0x2D): SYNE; 0xFFFF: PLLH is free running Instance number of SYNC or SYNE that is active, or 0xFFFF is PLLH is free running K (where fr. err = K*10(-E)): base of the last frequency error measured for the SYNC or SYNE that is active, or 0xFFFF if PLLH is free running E (where fr. err = K*10(-E)): exponent of the last frequency error measured for the SYNC or SYNE that is active, or 0xFFFF if PLLH is free running Frequency in KHz of the synchronization source Phase error measured on the PLLH. The 16th bit is the sign bit; the lowest 15 bits are the absolute value (i.e. without sign) of the phase error. This value is expressed in units of 40 ns. Phase error (see previous word) measured by the other PLLH. It may be not meaningful if this PLLH is out of service.

cccc =

dddd eeee ffff gggg hhhh

= = = = =

iiii = jjjj = kkkk = llll = mmmm = nnnn = oooo =

Specific Problems = 159 PLLH NOT READY DUE TO PWRD

Event Type = EQUIPMENT FAILURE EVENT Severity = MINOR Proposed Repair Actions = 18 WAIT FOR THE PLLH WARM UP (15 MINUTES)

Originator = 4202 MDHNWDCSC This error can be called in all the cases when the superordinated power of the network has just gone in service (that is from locked or from disabled to unlocked/enabled), and the ENABLE command has been sent to the network to clear the dependency state. The reason for this management is that the pllh is generally cold in this cases, and the network needs some time in order to work correctly. After 15 minutes, the device handler will clear this error, and the object will go back enabled without any operator action. If the time for coming back to service should be changed, in any case its value can be obtained (in seconds) from other info bbbb. To avoid calling this error when it is not necessary, an
A30808-X3247-K240-3-7619 21

Outputs OML:BSC

Base Station Controller

attempt is done do set the PLLH synchronized to the other one: if it remains steadily in this state for about one second, this error is not issued, and the network becomes immediately enabled.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Source code line where the error has been called time (in seconds) to wait before the automatic clear of this error not used not used not used not used not used not used not used not used not used not used not used not used not used

22

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

08 DISK PROBLEM
FAILURE EVENT REPORT: NAME = Probable cause = Specific Problems = Event Type = Event Time = Severity = Trend Indication = Notification Identifier = Correlated Notification Identifier = Related MO = Proposed Repair Actions = Additional Text = Originator = Additional Words =
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo <R.T.D.>

<R.T.D.> <R.T.D.> Disk Problem <see legend> <see legend> <R.T.D.> <see legend> <R.T.D.> <R.T.D.> <displayed only during Alarm Alignment> <R.T.D.> <R.T.D.> <see legend> <R.T.D.> <see legend>

Software Version =

Legend:

Specific Problems = 172 DISK NOT ALIGNED

Event Type = EQUIPMENT FAILURE EVENT Severity = MAJOR Proposed Repair Actions = 1 NO ACTION

Originator = 4305 MDH40IOSC We are trying to put a disk into service after a Status Manager request (ENABLE/UNLOCK) and it must be re-aligned.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll = = = = = = = = = = = = Module that generates the error Source code line of the module that generates the error not used not used not used not used not used not used not used not used not used not used

A30808-X3247-K240-3-7619

23

Outputs OML:BSC
mmmm = nnnn = oooo = not used not used not used

Base Station Controller

24

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

09 EQUIPMENT FAILURE
FAILURE EVENT REPORT: NAME = Probable cause = Specific Problems = Event Type = Event Time = Severity = Trend Indication = Notification Identifier = Correlated Notification Identifier = Related MO = Proposed Repair Actions = Additional Text = Originator = Additional Words =
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo <R.T.D.>

<R.T.D.> <R.T.D.> Equipment Failure <see legend> <see legend> <R.T.D.> <see legend> <R.T.D.> <R.T.D.> <displayed only during Alarm Alignment> <R.T.D.> <R.T.D.> <see legend> <R.T.D.> <see legend>

Software Version =

Legend:

##StartSpecProbl##
Specific Problems = 116 MEMT CARD FAILURE

Event Type = EQUIPMENT FAILURE EVENT Severity = MAJOR Proposed Repair Actions = 1 NO ACTION

Originator = 309 MOSICIOOT A semaphore of the TDPC DUAM is locked or the card is extracted; the routine "c_duam_check" on the TDPC has detected it. The information is passed, through the other copy of MEMT, to the MPCC output task.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj = = = = = = = = = = not used not used not used not used not used not used not used not used not used not used

A30808-X3247-K240-3-7619

25

Outputs OML:BSC
kkkk llll mmmm nnnn oooo = = = = = not used not used not used not used not used

Base Station Controller

##StartSpecProbl##
Specific Problems = 117 LICD PERMANENT ERROR

Event Type = EQUIPMENT FAILURE EVENT Severity = MINOR Proposed Repair Actions = 3 REPLACE THE ADDRESSED CARD

Originator = 4400 MDHLCDCDE A hardware or firmware problem has been detected by Device Controller while accessing a licd card.
aaaa bbbb cccc dddd eeee = = = = = Developer reserved: code line number where error is emitted Error originator where error was detected Developer reserved: code line number where error was detected Developer reserved: type of error occurred Developer reserved: cmdreg (low byte); type of licd (high byte): 0->DTLP; 1->QTLP V1; 2->QTLP V2. Mask of card line relays status (1=closed,0=open) Mask of card mate relays status (1=closed,0=open) Mask of physical pcm lines cutover status (1=line under cutover,0=line not cutovered) Ubex copy active (low byte); type of pcm working mode (high byte): 24(16h)->PCM24 ; 32(20h)->PCM32. Developer reserved: "hwchk": it should be 0x82, otherwise, a FW error has occurred Developer reserved: "cmdecho": value of the last command sent by MPCC to the FW of LICD Developer reserved: fwresp[0] Developer reserved: fwresp[1] Developer reserved: fwresp[2] Developer reserved: fwresp[3]

ffff gggg hhhh iiii

= = = =

jjjj = kkkk = llll mmmm nnnn oooo = = = =

Originator = 4404 MDHLCSASC A hardware error was found by alarm scan.This originator is used with two cases, indexed by the value present in the high byte of other info aaaa (es: AA01 means case of AA , and licd type QTLP V1. BB02 means case of BB , and licd type QTLP V2).
aaaa = In the low byte, Licd type (0=DTLP, 1=QTLP V1, 2=QTLP V2). In the high byte AA or BB to identify the correct meanig of the other info from cccc to oooo.

26

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
Developer reserved: code line number where error is emitted With aaaa=AAxx : Developer reserved: intalm With aaaa=BBxx : Developer reserved: fwres With aaaa=AAxx : Developer reserved: (sn_inter:2, relay_power:1, data_parity:1, mux:1, mdm0:1, mdm1:1, spare:9) With aaaa=BBxx : Developer reserved: cmdreg .Command register. With aaaa=AAxx : Developer reserved: physical lines alarmed for int.alarm With aaaa=BBxx : Developer reserved: Mask of card line relays status (1=closed,0=open). With aaaa=AAxx : Developer reserved: hwchk. It should be 0x82, otherwise, a FW error has occurred. With aaaa=BBxx : Developer reserved: Mask of card mate relays status (1=closed,0=open). With aaaa=AAxx : Developer reserved: cmdreg (low byte): type of pcm working mode (high byte):24(16h)->PCM24 ; 32(20h)->PCM32. With aaaa=BBxx : Developer reserved: Mask of physical pcm lines cutover status (1=line under cutover,0=line not cutovered). With aaaa=AAxx : Developer reserved: type of int.alarm for line 0 With aaaa=BBxx : Developer reserved: Ubex copy active (low byte); type of pcm working mode (high byte): 24(16h)->PCM24 ; 32(20h)->PCM32. With aaaa=AAxx : Developer reserved: type of int.alarm for line 1 With aaaa=BBxx : Developer reserved: hwchk. It should be 0x82, otherwise, a FW error has occurred. With aaaa=AAxx : Developer reserved: type of int.alarm for line 2 With aaaa=BBxx : Developer reserved: cmdecho. Value of the last command sent by MPCC to the FW of LICD. With aaaa=AAxx : Developer reserved: type of int.alarm for line 3 With aaaa=BBxx : Developer reserved: Developer reserved: fwresp[0] With aaaa=AAxx : Developer reserved: type of int.alarm for line 4 With aaaa=BBxx : Developer reserved: Developer reserved: fwresp[1] With aaaa=AAxx : Developer reserved: type of int.alarm for line 5 With aaaa=BBxx : Developer reserved: Developer reserved: fwresp[2] With aaaa=AAxx : Developer reserved: type of int.alarm for line 6 With aaaa=BBxx : Developer reserved: Developer reserved: fwresp[3] With aaaa=AAxx : Developer reserved: type of int.alarm for line 7 With aaaa=BBxx : Not meaningful

bbbb = cccc = dddd =

eeee = ffff =

gggg =

hhhh =

iiii =

jjjj =

kkkk = llll = mmmm = nnnn = oooo =

##StartSpecProbl##
Specific Problems = 119 IXLT CARD NOT IN FRAME

Event Type = EQUIPMENT FAILURE EVENT Severity = MAJOR Proposed Repair Actions = 1 NO ACTION

Originator = 4450 MDHIXDCSA this error occurs when the IXLT was found missing from the rack during the periodical scan alarm.
aaaa bbbb cccc dddd eeee ffff gggg hhhh = = = = = = = = the line number of the source module the retry counter Alarm register Sense register Loopback register Control register Interrupt register not used

A30808-X3247-K240-3-7619

27

Outputs OML:BSC
iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = not used not used not used not used not used not used not used

Base Station Controller

Originator = 4457 MDHIXDCSM this error occurs when the IXLT is going in service and it was not found in the rack.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = the line number of the source module the bit coded error not used. not used. not used. not used. not used. not used. not used. not used. not used. not used. not used. not used. not used.

##StartSpecProbl##
Specific Problems = 120 IXLT SOFTWARE LMT LINK ERROR

Event Type = EQUIPMENT FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 10000 XQ3LSIH this error occurs when the LMT link is down
aaaa bbbb cccc dddd eeee ffff gggg = = = = = = = (designer oriented) the source module (designer oriented) the line number (hex value) of the source module not used. not used. not used. not used. not used.

28

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = = = = = not used. not used. not used. not used. not used. not used. not used. not used.

hhhh iiii jjjj kkkk llll mmmm nnnn oooo

##StartSpecProbl##
Specific Problems = 121 IXLT SOFTWARE OMC LINK ERROR

Event Type = EQUIPMENT FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 10000 XQ3LSIH This error occurs when the RC-BSC link is down
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii = = = = = = = = = (designer oriented) the source module (designer oriented) the line number (hex value) of the source module not used. not used. not used. not used. not used. not used. designer oriented) Internal SW code error, possible values are: 0: error in PLP layer open 1: error in PLP layer start 2: error UNLINK DUAM 3: error LINK DUAM not used. not used. not used. not used. not used. not used.

jjjj kkkk llll mmmm nnnn oooo

= = = = = =

##StartSpecProbl##
Specific Problems = 122 IXLT FIRMWARE NOT READY

Event Type = EQUIPMENT FAILURE EVENT Severity = MAJOR Proposed Repair Actions = 7 SEE THE AUTOMATIC DIAGNOSTIC TEST RESULT
A30808-X3247-K240-3-7619 29

Outputs OML:BSC

Base Station Controller

Originator = 4450 MDHIXDCSA this error occurs when the IXLT FW was found not ready during the periodical scan alarm; the FW ready bit may be found reset either for HW/FW problem or because the IXLT SW decided to schedule a reset of the card, as a recovery of a fatal error.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = the line number of the source module the retry counter Alarm register. Sense register Loopback register Control register. Interrupt register. not used. not used. not used. not used. not used. not used. not used. not used.

##StartSpecProbl##
Specific Problems = 143 NTW PERMANENT FAILURE

Event Type = EQUIPMENT FAILURE EVENT Severity = MAJOR Proposed Repair Actions = 4 TEST THE ADDRESSED CARD(S)

Originator = 4203 MDHNWDCUF, 4205 MDHNWDCAL, 4206 MDHNWDCDE A permanent fault has been detected in a not specificied device of network (ubex, pllh, sn64, sn16 or SNAP). More details can be found in the other information (see below). This error occurs when the exact information about the HW fault has been lost due to a SW exception, possibly caused by NMI.
aaaa = bbbb = (Developer oriented) Source code line where the HW fault has been detected by the device driver Internal SW code error. The possible values are: 0=>Undefined HW error 1=>Loop test failed 2=>Bus parity error 3=>HW alarm active 5=>Alarm forcing failure 6=>CRC error (only PLLH) 7=>Wrong state of communication protocol (only PLLH) 8=>Time out during HW operation 0x11=>Unexpected state of HW 0x1A=>Invalid card type 0x1D=>Overflow of UBEX interrupts

30

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
0x1E=>NMI arisen while accessing HW affected device. The possible values are: 0: unknown1: 1 UBEX 2: PLLH 3: SN64 4: SN16 5: SNAP (Developer oriented) Originator which identifies the high level source file which has detected the failure (Developer oriented) Code line of the high level source file. Dump of the ubex alarm register. The following codes can be logically OR-ed: 0x1 (bit 0): Address parity error 0x2 (bit1): Data parity error 0x4 (bit 2) Chip select error Versions of the 2 PLLH (high byte): PLLH0 bit 8 .. 11; PLLH1 bit 12 .. 15. Value of the pllh alarm register (high byte). The following codes can be logically OR-ed: 0x1 (bit 0): If this bit is set, the PLLH is distributing its own clock signal, otherwise it is distributing the clock of the other PLLH 0x2 (bit 1): the input external synchronism is missing 0x4 (bit 2): the output clock is missing 0x8 (bit 3): the input external source to be measured to is missing 0x10 (bit 4): the PLLH is not synchronized with the other PLLH 0x20 (bit 5): address parity alarm on UBEX bus 0x40 (bit 6): data parity alarm on UBEX bus 0x80 (bit 7): watch dog alarm on the local processor Internal FW code of the PLLH (low byte) 0x1=>VCXO voltage out of range 0x2=>PLL unlocked 0x3=>Excessive jitter on synchronization source 0x4=>absence of the synchronization source 0x5=>last command from MPCC has not been understood 0x6=>VCXO voltage in the pre-alarm range 0x7=>interruption of the synchronization source 0x8=>eprom checksum failure 0x9=>fault on the DAC or on the ADC 0xA=>fault in the phase comparator 0xD=>CIOA fault (only PLLH V2) Dump of the alarm registers of the input block of SN (low byte). The following codes can be logically OR-ed: 0x1 (bit 0): SN16 or SNAP: UBEX address parity error; SN64: fixed to 0 0x2 (bit 1): SN16 or SNAP: UBEX data parity error; SN64: UBEX data parity error 0x4 (bit 2): SNAP: PCM parity alarm from LICD; SN16: PCM parity error from PPXX; SN64: UBEX address parity error 0x8 (bit 3): SNAP: PCM parity alarm from PPXX (valid only if input lines are configured at 2Mb/s); SN16: PCM parity error from LICD; SN64: fixed to 0 0x10 (bit 4): SNAP: Parity address/data alarm on the CRAM; SN16: Wrong parity inside the control RAM; SN64: timing alarm 0x20 (bit 5): SNAP: Timing/Re-Route alarm; SN16: Generic alarm on input gate array; SN64: fixed to 0 0x40 (bit 6): SNAP: No clock alarm; SN16: Lack of clock to input gate array; SN64: PCM parity error from LICD or PPXX 0x80 (bit 7): SNAP: No sync alarm; SN16: Lack of synchronism to the input gate array; SN64: not meaningful Dump of the alarm registers of the control block of SN (high byte). The following codes can be logically OR-ed: 0x1 (bit 0): SNAP or SN16: UBEX address parity error; SN64: fixed to 0 0x2 (bit 1): SNAP or SN16: UBEX data parity error; SN64: UBEX data parity error 0x4 (bit 2): SNAP or SN16: PLL alarm; SN64: UBEX address parity error 0x8 (bit 3): SNAP or SN16: FIFO error; SN64: generic RAM error 0x10 (bit 4): SNAP or SN16: Wrong parity inside the control RAM; SN64: timing alarm 0x20 (bit 5): SNAP: Internal timing alarm; SN16: Generic alarm on control gate array; SN64: fixed to 0 0x40 (bit 6): SNAP or SN16: Lack of clock to control gate array; SN64: not meaningful 0x80 (bit 7): SNAP or SN16: Lack of synchronism to the control gate array; SN64: not meaningful

cccc =

dddd = eeee = ffff =

gggg =

hhhh =

A30808-X3247-K240-3-7619

31

Outputs OML:BSC
iiii =

Base Station Controller

Low byte (meaningful only for SN64): dump of the global sense point. The lowest 4 bits are a redounded information of the other alarm registers of the SN64. The bit 7 (0x80) identifies the HW edition: if it is set, the edition number is greater than 2. High byte: dump of the alarm register of the output block of SN. The following codes can be logically OR-ed: 0x1 (bit 0): SNAP or SN16: UBEX address parity error; SN64: fixed to 0 0x2 (bit 1): SNAP or SN16: UBEX data parity error; SN64: UBEX data parity error 0x4 (bit 2): SNAP or SN16: parity error on parallel bus; SN64: UBEX address parity error 0x8 (bit 3): SNAP or SN16: PCM parity error from LICD; SN64: fixed to 0 0x10 (bit 4): SNAP or SN16: Wrong parity inside the control RAM; SN64: timing alarm 0x20 (bit 5): SNAP: Internal timing re-route alarm; SN16: Generic alarm on output gate array; SN64: comparison alarm 0x40 (bit 6): SNAP or SN16: Lack of clock to input gate array; SN64: PCM parity error on some output PCM line 0x80 (bit 7): SNAP or SN16: Lack of synchronism to the output gate array; SN64: not meaningful For SN64 or SN16 Bits 0-7: mask of incoming PCM 8 Mb/s lines with PCM parity alarm (lines no. 16-23); bits 8-15: not used. The 8 Mb/s lines are connected in this way: lines 0-1=>LICDS-0 lines 2-3=>LICD-0 lines 4-5=>LICD-1 lines 6-7=>LICD-2 lines 8-9=>LICD-3 lines 10-11=>LICD-4 lines 12-13=>LICD-5 lines 14-15=>LICD-6 lines 16-17=>LICD-7 lines 18-19=>LICD-8 lines 20-21=>LICDS-1 lines 22-23=>All PPCC/PPLD/PPCU For SNAP card: mask of the alarmated incoming PCM 8 Mb/s lines 0..15. The lines are connected in this way; lines 0..3 => LICDS-0 lines 4..7 => LICD-0 lines 8..11 => LICD-1 lines 12..15 => LICD-2 For SN16 or SN64: mask of incoming PCM 8 Mb/s lines with PCM parity alarm (lines no. 0-15); see previous word For SNAP card: mask of the alarmated incoming PCM 8 Mb/s lines 16..31. The lines are connected in this way; lines 16..19 => LICD-3 lines 20..23 => LICD-4 lines 24..27 => LICD-5 lines 28..31 => LICD-6 For SN16 or SN64: Bits 0-3: mask of PCM 2 Mb/s lines coming from PPXX with PCM parity alarm; bits 4-15: not used. The 2 Mb/s lines from PPXX are connected in this way: line 0: PPCC-0,1; PPLD 0,1,2 line 1: PPLD 3,4,5,6 line 2: PPLD 7,8,9,10 or PPCU 2,3 line 3: PPLD 11,12,13,14 or PPCU 0,1 For SNAP card: mask of the alarmated incoming PCM 8 Mb/s lines 32..43. The lines are connected in this way; lines 32..35 => LICD-7 lines 36..39 => LICD-8 lines 40..43 => LICDS-1 lines 44..47 => NOT USED For SN16 or SN64: Bits 0-7: mask of outgoing PCM 8 Mb/s lines with comparison alarm (lines 16-23); bits 815: not used. The correspondence between lines and LICD is the same as the word jjjj For SNAP card:

jjjj =

kkkk =

llll =

mmmm =

32

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
mask of the alarmated incoming PCM 8 Mb/s lines 48..55 coming from PPXX. The lines are connected in this way; lines 48..49 => PPXL 0..1 lines 50 ..55 => PPXU 0..5 lines 56..59 => NOT USED For SN16 or SN64: mask of outgoing PCM 8 Mb/s lines with comparison alarm (lines 0-15). See previous word. For SNAP card: comparison alarm on incoming PCM lines 0..15 Bit 0: Timing alarm flag of SN; bit 1: ubex bus parity alarm flag of SN (data and/or address); bit 2: cyclic test alarm (SN16 or SNAP) or control ram failure (SN64); bit 3: internal generic alarm; bit 4: alarm on ctrl G. A.; bit 5: alarm on input G. A.; bit 6: alarm on output G. A.; bit 7: fifo alarm (only SN16 and SNAP); bits 8-15: not used.

nnnn =

oooo =

##StartSpecProbl##
Specific Problems = 144 UBEX PERMANENT FAILURE

Event Type = EQUIPMENT FAILURE EVENT Severity = MAJOR Proposed Repair Actions = 4 TEST THE ADDRESSED CARD(S)

Originator = 4200 MDHNWABAF, 4201 MDHNWDCHN, 4202 MDHNWDCSC, 4203 MDHNWDCUF, 4204 MDHNWININ, 4205 MDHNWDCAL, 4220 MDHUBDDCR A permanent fault has been detected on the ubex of the affected network copy. More details can be found in the other information (see below).
aaaa = bbbb = (Developer oriented) source code line where the HW fault has been detected by the device driver Internal SW code error. The possible values are: 0=>Undefined HW error1=>Loop test failed 2=>Bus parity error 3=>HW alarm active 5=>Alarm forcing failure 6=>CRC error (only PLLH) 7=>Wrong state of communication protocol (only PLLH) 8=>Time out during HW operation 0x11=>Unexpected state of HW 0x1A=>Invalid card type 0x1D=>Overflow of UBEX interrupts 0x1E=>NMI arisen while accessing HW affected device (it must be consistent with the error identity and the originator). The possible values are: 0: unknown 1: UBEX (Developer oriented) originator which identifies the high level source file which has detected the failure (Developer oriented) code line of the high level source file. Dump of the ubex alarm register (low byte). The following codes can be logically OR-ed: 0x1 (bit 0): Address parity error 0x2 (bit1): Data parity error 0x4 (bit 2) Chip select error Versions of the 2 PLLH (high byte): PLLH0 bit 8 .. 11; PLLH1 bit 12 .. 15. Value of the pllh alarm register (high byte). The following codes can be logically OR-ed: 0x1 (bit 0): If this bit is set, the PLLH is distributing its own clock signal, otherwise it is distributing the clock of the other PLLH 0x2 (bit 1): the input external synchronism is missing 0x4 (bit 2): the output clock is missing

cccc =

dddd = eeee = ffff =

gggg =

A30808-X3247-K240-3-7619

33

Outputs OML:BSC
0x8 (bit 3): the input external source to be measured to is missing 0x10 (bit 4): the PLLH is not synchronized with the other PLLH 0x20 (bit 5): address parity alarm on UBEX bus 0x40 (bit 6): data parity alarm on UBEX bus 0x80 (bit 7): watch dog alarm on the local processor

Base Station Controller

hhhh =

Internal FW code of the PLLH (low byte) 0x1=>VCXO voltage out of range 0x2=>PLL unlocked 0x3=>Excessive jitter on synchronization source 0x4=>absence of the synchronization source 0x5=>last command from MPCC has not been understood 0x6=>VCXO voltage in the pre-alarm range 0x7=>interruption of the synchronization source 0x8=>eprom checksum failure 0x9=>fault on the DAC or on the ADC 0xA=>fault in the phase comparator 0xD=>CIOA fault (only PLLH V2) Dump of the alarm registers of the input block of SN (low byte). The following codes can be logically OR-ed: 0x1 (bit 0): SN16 or SNAP: UBEX address parity error; SN64: fixed to 0 0x2 (bit 1): SN16 or SNAP: UBEX data parity error; SN64: UBEX data parity error 0x4 (bit 2): SNAP: PCM parity alarm from LICD; SN16: PCM parity error from PPXX; SN64: UBEX address parity error 0x8 (bit 3): SNAP: PCM parity alarm from PPXX (valid only if input lines are configured at 2Mb/s); SN16: PCM parity error from LICD; SN64: fixed to 0 0x10 (bit 4): SNAP: Parity address/data alarm on the CRAM; SN16: Wrong parity inside the control RAM; SN64: timing alarm 0x20 (bit 5): SNAP: Timing/Re-Route alarm; SN16: Generic alarm on input gate array; SN64: fixed to 0 0x40 (bit 6): SNAP: No clock alarm; SN16: Lack of clock to input gate array; SN64: PCM parity error from LICD or PPXX 0x80 (bit 7): SNAP: No sync alarm; SN16: Lack of synchronism to the input gate array; SN64: not meaningful Dump of the alarm registers of the control block of SN (high byte). The following codes can be logically OR-ed: 0x1 (bit 0): SNAP or SN16: UBEX address parity error; SN64: fixed to 0 0x2 (bit 1): SNAP or SN16: UBEX data parity error; SN64: UBEX data parity error 0x4 (bit 2): SNAP or SN16: PLL alarm; SN64: UBEX address parity error 0x8 (bit 3): SNAP or SN16: FIFO error; SN64: generic RAM error 0x10 (bit 4): SNAP or SN16: Wrong parity inside the control RAM; SN64: timing alarm 0x20 (bit 5): SNAP: Internal timing alarm; SN16: Generic alarm on control gate array; SN64: fixed to 0 0x40 (bit 6): SNAP or SN16: Lack of clock to control gate array; SN64: not meaningful 0x80 (bit 7): SNAP or SN16: Lack of synchronism to the control gate array; SN64: not meaningful

iiii =

Low byte (meaningful only for SN64): dump of the global sense point. The lowest 4 bits are a redounded information of the other alarm registers of the SN64. The bit 7 (0x80) identifies the HW edition: if it is set, the edition number is greater than 2. High byte: dump of the alarm register of the output block of SN. The following codes can be logically OR-ed: 0x1 (bit 0): SNAP or SN16: UBEX address parity error; SN64: fixed to 0 0x2 (bit 1): SNAP or SN16: UBEX data parity error; SN64: UBEX data parity error 0x4 (bit 2): SNAP or SN16: parity error on parallel bus; SN64: UBEX address parity error 0x8 (bit 3): SNAP or SN16: PCM parity error from LICD; SN64: fixed to 0 0x10 (bit 4): SNAP or SN16: Wrong parity inside the control RAM; SN64: timing alarm 0x20 (bit 5): SNAP: Internal timing re-route alarm; SN16: Generic alarm on output gate array; SN64: comparison alarm 0x40 (bit 6): SNAP or SN16: Lack of clock to input gate array; SN64: PCM parity error on some output PCM line 0x80 (bit 7): SNAP or SN16: Lack of synchronism to the output gate array; SN64: not meaningful For SN64 or SN16 Bits 0-7: mask of incoming PCM 8 Mb/s lines with PCM parity alarm (lines no. 16-23); bits

jjjj =

34

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
8-15: not used. The 8 Mb/s lines are connected in this way: lines 0-1=>LICDS-0 lines 2-3=>LICD-0 lines 4-5=>LICD-1 lines 6-7=>LICD-2 lines 8-9=>LICD-3 lines 10-11=>LICD-4 lines 12-13=>LICD-5 lines 14-15=>LICD-6 lines 16-17=>LICD-7 lines 18-19=>LICD-8 lines 20-21=>LICDS-1 lines 22-23=>All PPCC/PPLD/PPCU For SNAP card: mask of the alarmed incoming PCM 8 Mb/s lines 0..15. The lines are connected in this way; lines 0..3 => LICDS-0 lines 4..7 => LICD-0 lines 8..11 => LICD-1 lines 12..15 => LICD-2 For SN16 or SN64: mask of incoming PCM 8 Mb/s lines with PCM parity alarm (lines no. 0-15); see previous word For SNAP card: mask of the alarmated incoming PCM 8 Mb/s lines 16..31. The lines are connected in this way; lines 16..19 => LICD-3 lines 20..23 => LICD-4 lines 24..27 => LICD-5 lines 28..31 => LICD-6 For SN16 or SN64: Bits 0-3: mask of PCM 2 Mb/s lines coming from PPXX with PCM parity alarm; bits 4-15: not used. The 2 Mb/s lines from PPXX are connected in this way: line 0: PPCC-0,1; PPLD 0,1,2 line 1: PPLD 3,4,5,6 line 2: PPLD 7,8,9,10 or PPCU 2,3 line 3: PPLD 11,12,13,14 or PPCU 0,1 For SNAP card: mask of the alarmated incoming PCM 8 Mb/s lines 32..43. The lines are connected in this way; lines 32..35 => LICD-7 lines 36..39 => LICD-8 lines 40..43 => LICDS-1 lines 44..47 => NOT USED For SN16 or SN64: Bits 0-7: mask of outgoing PCM 8 Mb/s lines with comparison alarm (lines 16-23); bits 815: not used. The correspondence between lines and LICD is the same as the word jjjj For SNAP card: mask of the alarmated incoming PCM 8 Mb/s lines 48..55 coming from PPXX. The lines are connected in this way; lines 48..49 => PPXL 0..1 lines 50 ..55 => PPXU 0..5 lines 56..59 => NOT USED For SN16 or SN64: mask of outgoing PCM 8 Mb/s lines with comparison alarm (lines 0-15). See previous word. For SNAP card: comparison alarm on incoming PCM lines 0..15 Bit 0: Timing alarm flag of SN; bit 1: ubex bus parity alarm flag of SN (data and/or address); bit 2: cyclic test alarm (SN16 or SNAP) or control ram failure (SN64); bit 3: internal generic alarm; bit 4: alarm on ctrl G. A.; bit 5: alarm on input G. A.; bit 6: alarm on output G. A.; bit 7: fifo alarm (only SN16 and SNAP); bits 8-15: not used.

kkkk =

llll =

mmmm =

nnnn =

oooo =

A30808-X3247-K240-3-7619

35

Outputs OML:BSC

Base Station Controller

##StartSpecProbl##
Specific Problems = 145 PLLH PERMANENT FAILURE

Event Type = EQUIPMENT FAILURE EVENT Severity = MAJOR Proposed Repair Actions = 4 TEST THE ADDRESSED CARD(S)

Originator = 4200 MDHNWABAF, 4201 MDHNWDCHN, 4202 MDHNWDCSC, 4203 MDHNWDCUF, 4204 MDHNWININ, 4205 MDHNWDCAL, 4230 MDHPLDDCR A permanent fault has been detected on the pllh of the related network copy. More details can be found in the other information (see below).
aaaa = bbbb = (Developer oriented) Source code line where the HW fault has been detected by the device driver Internal SW code error. The possible values are: 0=>Undefined HW error1=>Loop test failed 2=>Bus parity error 3=>HW alarm active 5=>Alarm forcing failure 6=>CRC error (only PLLH) 7=>Wrong state of communication protocol (only PLLH) 8=>Time out during HW operation 0x11=>Unexpected state of HW 0x1A=>Invalid card type 0x1D=>Overflow of UBEX interrupts 0x1E=>NMI arisen while accessing HW affected device (it must be consistent with the error identity and the originator). The possible values are: 0: unknown 2: PLLH (Developer oriented) Originator which identifies the high level source file which has detected the failure (Developer oriented) Code line of the high level source file. Dump of the ubex alarm register. The following codes can be logically OR-ed: 0x1 (bit 0): Address parity error 0x2 (bit1): Data parity error 0x4 (bit 2) Chip select error Versions of the 2 PLLH (high byte): PLLH0 bit 8 .. 11; PLLH1 bit 12 .. 15. Value of the pllh alarm register (high byte). The following codes can be logically OR-ed: 0x1 (bit 0): If this bit is set, the PLLH is distributing its own clock signal, otherwise it is distributing the clock of the other PLLH 0x2 (bit 1): the input external synchronism is missing 0x4 (bit 2): the output clock is missing 0x8 (bit 3): the input external source to be measured to is missing 0x10 (bit 4): the PLLH is not synchronized with the other PLLH 0x20 (bit 5): address parity alarm on UBEX bus 0x40 (bit 6): data parity alarm on UBEX bus 0x80 (bit 7): watch dog alarm on the local processor Internal FW code of the PLLH (low byte )0x1=>VCXO voltage out of range 0x2=>PLL unlocked0x3=>Excessive jitter on synchronization source 0x4=>absence of the synchronization source 0x5=>last command from MPCC has not been understood 0x6=>VCXO voltage in the pre-alarm range 0x7=>interruption of the synchronization source 0x8=>eprom checksum failure 0x9=>fault on the DAC or on the ADC 0xA=>fault in the phase comparator 0xD=>CIOA fault (only PLLH V2) Dump of the alarm registers of the input block of SN (low byte). The following codes can be logically OR-ed: 0x1 (bit 0): SN16 or SNAP: UBEX address parity error; SN64: fixed to 0 0x2 (bit 1): SN16 or SNAP: UBEX data parity error; SN64: UBEX data parity error

cccc =

dddd = eeee = ffff =

gggg =

hhhh =

36

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
0x4 (bit 2): SNAP: PCM parity alarm from LICD; SN16: PCM parity error from PPXX; SN64: UBEX address parity error 0x8 (bit 3): SNAP: PCM parity alarm from PPXX (valid only if input lines are configured at 2Mb/s); SN16: PCM parity error from LICD; SN64: fixed to 0 0x10 (bit 4): SNAP: Parity address/data alarm on the CRAM; SN16: Wrong parity inside the control RAM; SN64: timing alarm 0x20 (bit 5): SNAP: Timing/Re-Route alarm; SN16: Generic alarm on input gate array; SN64: fixed to 0 0x40 (bit 6): SNAP: No clock alarm; SN16: Lack of clock to input gate array; SN64: PCM parity error from LICD or PPXX 0x80 (bit 7): SNAP: No sync alarm; SN16: Lack of synchronism to the input gate array; SN64: not meaningful Dump of the alarm registers of the control block of SN (high byte). The following codes can be logically OR-ed: 0x1 (bit 0): SNAP or SN16: UBEX address parity error; SN64: fixed to 0 0x2 (bit 1): SNAP or SN16: UBEX data parity error; SN64: UBEX data parity error 0x4 (bit 2): SNAP or SN16: PLL alarm; SN64: UBEX address parity error 0x8 (bit 3): SNAP or SN16: FIFO error; SN64: generic RAM error 0x10 (bit 4): SNAP or SN16: Wrong parity inside the control RAM; SN64: timing alarm 0x20 (bit 5): SNAP: Internal timing alarm; SN16: Generic alarm on control gate array; SN64: fixed to 0 0x40 (bit 6): SNAP or SN16: Lack of clock to control gate array; SN64: not meaningful 0x80 (bit 7): SNAP or SN16: Lack of synchronism to the control gate array; SN64: not meaningful Low byte (meaningful only for SN64): dump of the global sense point. The lowest 4 bits are a redounded information of the other alarm registers of the SN64. The bit 7 (0x80) identifies the HW edition: if it is set, the edition number is greater than 2. High byte: dump of the alarm register of the output block of SN. The following codes can be logically OR-ed: 0x1 (bit 0): SNAP or SN16: UBEX address parity error; SN64: fixed to 0 0x2 (bit 1): SNAP or SN16: UBEX data parity error; SN64: UBEX data parity error 0x4 (bit 2): SNAP or SN16: parity error on parallel bus; SN64: UBEX address parity error 0x8 (bit 3): SNAP or SN16: PCM parity error from LICD; SN64: fixed to 0 0x10 (bit 4): SNAP or SN16: Wrong parity inside the control RAM; SN64: timing alarm 0x20 (bit 5): SNAP: Internal timing re-route alarm; SN16: Generic alarm on output gate array; SN64: comparison alarm 0x40 (bit 6): SNAP or SN16: Lack of clock to input gate array; SN64: PCM parity error on some output PCM line 0x80 (bit 7): SNAP or SN16: Lack of synchronism to the output gate array; SN64: not meaningful For SN64 or SN16 Bits 0-7: mask of incoming PCM 8 Mb/s lines with PCM parity alarm (lines no. 16-23); bits 8-15: not used. The 8 Mb/s lines are connected in this way: lines 0-1=>LICDS-0 lines 2-3=>LICD-0 lines 4-5=>LICD-1 lines 6-7=>LICD-2 lines 8-9=>LICD-3 lines 10-11=>LICD-4 lines 12-13=>LICD-5 lines 14-15=>LICD-6 lines 16-17=>LICD-7 lines 18-19=>LICD-8 lines 20-21=>LICDS-1 lines 22-23=>All PPCC/PPLD/PPCU For SNAP card: mask of the alarmated incoming PCM 8 Mb/s lines 0..15. The lines are connected in this way; lines 0..3 => LICDS-0 lines 4..7 => LICD-0 lines 8..11 => LICD-1 lines 12..15 => LICD-2 For SN16 or SN64: mask of incoming PCM 8 Mb/s lines with PCM parity alarm (lines no. 0-15); see previous word

iiii =

jjjj =

kkkk =

A30808-X3247-K240-3-7619

37

Outputs OML:BSC

Base Station Controller

llll =

mmmm =

nnnn =

oooo =

For SNAP card: mask of the alarmated incoming PCM 8 Mb/s lines 16..31. The lines are connected in this way; lines 16..19 => LICD-3 lines 20..23 => LICD-4 lines 24..27 => LICD-5 lines 28..31 => LICD-6 For SN16 or SN64: Bits 0-3: mask of PCM 2 Mb/s lines coming from PPXX with PCM parity alarm; bits 4-15: not used. The 2 Mb/s lines from PPXX are connected in this way: line 0: PPCC-0,1; PPLD 0,1,2 line 1: PPLD 3,4,5,6 line 2: PPLD 7,8,9,10 or PPCU 2,3 line 3: PPLD 11,12,13,14 or PPCU 0,1 For SNAP card: mask of the alarmated incoming PCM 8 Mb/s lines 32..43. The lines are connected in this way; lines 32..35 => LICD-7 lines 36..39 => LICD-8 lines 40..43 => LICDS-1 lines 44..47 => NOT USED For SN16 or SN64: Bits 0-7: mask of outgoing PCM 8 Mb/s lines with comparison alarm (lines 16-23); bits 815: not used. The correspondence between lines and LICD is the same as the word jjjj For SNAP card: mask of the alarmated incoming PCM 8 Mb/s lines 48..55 coming from PPXX. The lines are connected in this way; lines 48..49 => PPXL 0..1 lines 50 ..55 => PPXU 0..5 lines 56..59 => NOT USED For SN16 or SN64: mask of outgoing PCM 8 Mb/s lines with comparison alarm (lines 0-15). See previous word. For SNAP card: comparison alarm on incoming PCM lines 0..15 Bit 0: Timing alarm flag of SN; bit 1: ubex bus parity alarm flag of SN (data and/or address); bit 2: cyclic test alarm (SN16 or SNAP) or control ram failure (SN64); bit 3: internal generic alarm; bit 4: alarm on ctrl G. A.; bit 5: alarm on input G. A.; bit 6: alarm on output G. A.; bit 7: fifo alarm (only SN16 and SNAP); bits 8-15: not used.

##StartSpecProbl##
Specific Problems = 146 SN64 PERMANENT FAILURE

Event Type = EQUIPMENT FAILURE EVENT Severity = MAJOR Proposed Repair Actions = 4 TEST THE ADDRESSED CARD(S)

Originator = 4200 MDHNWABAF, 4201 MDHNWDCHN, 4202 MDHNWDCSC, 4203 MDHNWDCUF, 4204 MDHNWININ, 4205 MDHNWDCAL, 4207 MDHNWDCSS, 4240 MDHSNDDCR A permanent fault has been detected on the SN64 of the related network copy. More details can be found in the other information (see below).
aaaa = bbbb = (Developer oriented) Source code line where the HW fault has been detected by the device driver Internal SW code error. The possible values are: 0=>Undefined HW error 1=>Loop test failed

38

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
2=>Bus parity error 3=>HW alarm active 5=>Alarm forcing failure 6=>CRC error (only PLLH) 7=>Wrong state of communication protocol (only PLLH) 8=>Time out during HW operation 0x11=>Unexpected state of HW 0x1A=>Invalid card type 0x1D=>Overflow of UBEX interrupts 0x1E=>NMI arisen while accessing HW affected device (it must be consistent with the error identity and the originator). The possible values are: 0: unknown 3: SN64 (Developer oriented) Originator which identifies the high level source file which has detected the failure (Developer oriented) Code line of the high level source file. Dump of the ubex alarm register. The following codes can be logically OR-ed: 0x1 (bit 0): Address parity error 0x2 (bit1): Data parity error 0x4 (bit 2) Chip select error Versions of the 2 PLLH (high byte): PLLH0 bit 8 .. 11; PLLH1 bit 12 .. 15. Value of the pllh alarm register (high byte). The following codes can be logically OR-ed: 0x1 (bit 0): If this bit is set, the PLLH is distributing its own clock signal, otherwise it is distributing the clock of the other PLLH 0x2 (bit 1): the input external synchronism is missing 0x4 (bit 2): the output clock is missing 0x8 (bit 3): the input external source to be measured to is missing 0x10 (bit 4): the PLLH is not synchronized with the other PLLH 0x20 (bit 5): address parity alarm on UBEX bus 0x40 (bit 6): data parity alarm on UBEX bus 0x80 (bit 7): watch dog alarm on the local processor Internal FW code of the PLLH (low byte) 0x1=>VCXO voltage out of range 0x2=>PLL unlocked 0x3=>Excessive jitter on synchronization source 0x4=>absence of the synchronization source 0x5=>last command from MPCC has not been understood 0x6=>VCXO voltage in the pre-alarm range 0x7=>interruption of the synchronization source 0x8=>eprom checksum failure 0x9=>fault on the DAC or on the ADC 0xA=>fault in the phase comparator 0xD=>CIOA fault (only PLLH V2) Dump of the alarm registers of the input block of SN (low byte). The following codes can be logically OR-ed: 0x1 (bit 0): fixed to 0 0x2 (bit 1): UBEX data parity error 0x4 (bit 2): UBEX address parity error 0x8 (bit 3): fixed to 0 0x10 (bit 4):timing alarm 0x20 (bit 5): fixed to 0 0x40 (bit 6): PCM parity error from LICD or PPXX 0x80 (bit 7): not meaningful Dump of the alarm registers of the control block of SN (high byte). The following codes can be logically OR-ed: 0x1 (bit 0): fixed to 0 0x2 (bit 1): UBEX data parity error 0x4 (bit 2): UBEX address parity error 0x8 (bit 3): generic RAM error 0x10 (bit 4):timing alarm 0x20 (bit 5): fixed to 0 0x40 (bit 6): not meaningful 0x80 (bit 7): not meaningful Low byte: dump of the global sense point. The lowest 4 bits are a redounded information of the other alarm registers of the SN64. The bit 7 (0x80) identifies

cccc =

dddd = eeee = ffff =

gggg =

hhhh =

iiii =

A30808-X3247-K240-3-7619

39

Outputs OML:BSC
the HW edition: if it is set, the edition number is greater than 2.

Base Station Controller

jjjj =

kkkk = llll =

mmmm = nnnn = oooo =

High byte: dump of the alarm register of the output block of SN. The following codes can be logically OR-ed: 0x1 (bit 0): fixed to 0 0x2 (bit 1): UBEX data parity error 0x4 (bit 2): address parity error 0x8 (bit 3): fixed to 0 0x10 (bit 4): timing alarm 0x20 (bit 5): comparison alarm 0x40 (bit 6): PCM parity error on some output PCM line 0x80 (bit 7): not meaningful For SN64 or SN16 Bits 0-7: mask of incoming PCM 8 Mb/s lines with PCM parity alarm (lines no. 16-23); bits 8-15: not used. The 8 Mb/s lines are connected in this way: lines 0-1=>LICDS-0 lines 2-3=>LICD-0 lines 4-5=>LICD-1 lines 6-7=>LICD-2 lines 8-9=>LICD-3 lines 10-11=>LICD-4 lines 12-13=>LICD-5 lines 14-15=>LICD-6 lines 16-17=>LICD-7 lines 18-19=>LICD-8 lines 20-21=>LICDS-1 lines 22-23=>All PPCC/PPLD/PPCU mask of incoming PCM 8 Mb/s lines with PCM parity alarm (lines no. 0-15); see previous word Bits 0-3: mask of PCM 2 Mb/s lines coming from PPXX with PCM parity alarm; bits 4-15: not used. The 2 Mb/s lines from PPXX are connected in this way: line 0: PPCC-0,1; PPLD 0,1,2 line 1: PPLD 3,4,5,6 line 2: PPLD 7,8,9,10 or PPCU 2,3 line 3: PPLD 11,12,13,14 or PPCU 0,1 Bits 0-7: mask of outgoing PCM 8 Mb/s lines with comparison alarm (lines 16-23); bits 815: not used. The correspondence between lines and LICD is the same as the word jjjj mask of outgoing PCM 8 Mb/s lines with comparison alarm (lines 0-15). See previous word. Bit 0: Timing alarm flag of SN; bit 1: ubex bus parity alarm flag of SN (data and/or address); bit 2:control ram failure; bit 3: internal generic alarm; bit 4: alarm on ctrl G. A.; bit 5: alarm on input G. A.; bit 6: alarm on output G. A.; bits 7-15: not used.

##StartSpecProbl##
Specific Problems = 151 LICD ACCESS PROBLEM

Event Type = EQUIPMENT FAILURE EVENT Severity = MINOR Proposed Repair Actions = 22 TEST THE LICD. IF OK, REPLACE THE UBEX

Originator = 4400 MDHLCDCDE Licd card does not answer. This sometimes means that card has been extracted
aaaa = bbbb = cccc = Developer reserved: code line number where error is emitted Error originator where error was detected Developer reserved: code line number where error was detected

40

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
Developer reserved: type of error occurred Developer reserved: cmdreg (low byte); type of licd (high byte): 0->DTLP; 1->QTLP V1; 2->QTLP V2. Mask of card line relays status (1=closed,0=open) Mask of card mate relays status (1=closed,0=open) Mask of physical pcm lines cutover status (1=line under cutover,0=line not cutovered) Ubex copy active (low byte); type of pcm working mode (high byte): 24(16h)->PCM24 ; 32(20h)->PCM32. Developer reserved: "hwchk" it should be 0x82, otherwise, a FW error has occurred Developer reserved: "cmdecho" value of the last command sent by MPCC to the FW of LICD Developer reserved: fwresp[0] Developer reserved: fwresp[1] Developer reserved: fwresp[2] Developer reserved: fwresp[3]

dddd = eeee =

ffff gggg hhhh iiii

= = = =

jjjj = kkkk = llll mmmm nnnn oooo = = = =

Originator = 4404 MDHLCSASC Licd card does not answer. This sometimes means that card has been extracted
aaaa bbbb cccc dddd eeee ffff gggg hhhh = = = = = = = = Licd type (0=DTLP, 1=QTLP V1, 2=QTLP V2) Developer reserved: code line number where error is emitted Developer reserved: error occurred Developer reserved: shadowdata cmdreg Mask of last card line relays status (1=closed,0=open) Mask of last card mate relays status (1=closed,0=open) Mask of last physical pcm lines cutover status (1=line under cutover,0=line not cutovered) Last Ubex copy active (low byte); type of pcm working mode (high byte): 24(16h)->PCM24 ; 32(20h)->PCM32. Developer reserved: shadowdata "hwchk": it should be 0x82, otherwise, a FW error has occurred Developer reserved: shadowdata "cmdecho" value of the last command sent by MPCC to the FW of LICD Developer reserved: shadowdata fwresp[0] Developer reserved: shadowdata fwresp[1] Developer reserved: shadowdata fwresp[2] Developer reserved: shadowdata fwresp[3] not used

iiii = jjjj = kkkk llll mmmm nnnn oooo = = = = =

##StartSpecProbl##
Specific Problems = 155 SN16 PERMANENT FAILURE

Event Type = EQUIPMENT FAILURE EVENT Severity = MAJOR Proposed Repair Actions = 4 TEST THE ADDRESSED CARD(S)

A30808-X3247-K240-3-7619

41

Outputs OML:BSC

Base Station Controller

Originator = 4200 MDHNWABAF, 4202 MDHNWDCSC, 4205 MDHNWDCAL, 4207 MDHNWDCSS, 4250 MDH16DDCR A permanent fault has been detected on the sn16 of the affected network copy. More details can be found in the other information (see below).
aaaa = bbbb = (Developer oriented) Source code line where the HW fault has been detected by the device driver Internal SW code error. The possible values are: 0=>Undefined HW error 1=>Loop test failed 2=>Bus parity error 3=>HW alarm active 5=>Alarm forcing failure 6=>CRC error (only PLLH) 7=>Wrong state of communication protocol (only PLLH) 8=>Time out during HW operation 0x11=>Unexpected state of HW 0x1A=>Invalid card type 0x1D=>Overflow of UBEX interrupts 0x1E=>NMI arisen while accessing HW affected device (it must be consistent with the error identity and the originator). The possible values are: 0: unknown 4: SN16 (Developer oriented) Originator which identifies the high level source file which has detected the failure (Developer oriented) Code line of the high level source file. Dump of the ubex alarm register. The following codes can be logically OR-ed: 0x1 (bit 0): Address parity error 0x2 (bit1): Data parity error 0x4 (bit 2) Chip select error Versions of the 2 PLLH (high byte): PLLH0 bit 8 .. 11; PLLH1 bit 12 .. 15. Value of the pllh alarm register (high byte). The following codes can be logically OR-ed: 0x1 (bit 0): If this bit is set, the PLLH is distributing its own clock signal, otherwise it is distributing the clock of the other PLLH 0x2 (bit 1): the input external synchronism is missing 0x4 (bit 2): the output clock is missing 0x8 (bit 3): the input external source to be measured to is missing 0x10 (bit 4): the PLLH is not synchronized with the other PLLH 0x20 (bit 5): address parity alarm on UBEX bus 0x40 (bit 6): data parity alarm on UBEX bus 0x80 (bit 7): watch dog alarm on the local processor Internal FW code of the PLLH (low byte) 0x1=>VCXO voltage out of range 0x2=>PLL unlocked 0x3=>Excessive jitter on synchronization source 0x4=>absence of the synchronization source 0x5=>last command from MPCC has not been understood 0x6=>VCXO voltage in the pre-alarm range 0x7=>interruption of the synchronization source 0x8=>eprom checksum failure 0x9=>fault on the DAC or on the ADC 0xA=>fault in the phase comparator0xD=>CIOA fault (only PLLH V2) Dump of the alarm registers of the input block of SN (low byte). The following codes can be logically OR-ed: 0x1 (bit 0): UBEX address parity error; 0x2 (bit 1): UBEX data parity error 0x4 (bit 2): PCM parity error from PPXX 0x8 (bit 3): PCM parity error from LICD 0x10 (bit 4): Wrong parity inside the control RAM 0x20 (bit 5): Generic alarm on input gate array 0x40 (bit 6): Lack of clock to input gate array 0x80 (bit 7): Lack of synchronism to the input gate array Dump of the alarm registers of the control block of SN (high byte). The following codes can be logically OR-ed:

cccc =

dddd = eeee = ffff =

gggg =

hhhh =

42

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
0x1 (bit 0): UBEX address parity error 0x2 (bit 1): UBEX data parity error 0x4 (bit 2): PLL alarm 0x8 (bit 3): FIFO error 0x10 (bit 4): Wrong parity inside the control RAM 0x20 (bit 5): Generic alarm on control gate array 0x40 (bit 6): Lack of clock to control gate array 0x80 (bit 7): Lack of synchronism to the control gate array Low byte not meaninigful High byte: dump of the alarm register of the output block of SN. The following codes can be logically OR-ed: 0x1 (bit 0): UBEX address parity error 0x2 (bit 1): UBEX data parity error 0x4 (bit 2): parity error on parallel bus 0x8 (bit 3): PCM parity error from LICD 0x10 (bit 4): Wrong parity inside the control RAM 0x20 (bit 5): Generic alarm on output gate array 0x40 (bit 6): Lack of clock to input gate array 0x80 (bit 7): Lack of synchronism to the output gate array Bits 0-7: mask of incoming PCM 8 Mb/s lines with PCM parity alarm (lines no. 16-23); bits 8-15: not used. The 8 Mb/s lines are connected in this way: lines 0-1=>LICDS-0 lines 2-3=>LICD-0 lines 4-5=>LICD-1 lines 6-7=>LICD-2 lines 8-9=>LICD-3 lines 10-11=>LICD-4 lines 12-13=>LICD-5 lines 14-15=>LICD-6 lines 16-17=>LICD-7 lines 18-19=>LICD-8 lines 20-21=>LICDS-1 lines 22-23=>All PPCC/PPLD/PPCU mask of incoming PCM 8 Mb/s lines with PCM parity alarm (lines no. 0-15); see previous word Bits 0-3: mask of PCM 2 Mb/s lines coming from PPXX with PCM parity alarm; bits 4-15: not used. The 2 Mb/s lines from PPXX are connected in this way: line 0: PPCC-0,1; PPLD 0,1,2 line 1: PPLD 3,4,5,6 line 2: PPLD 7,8,9,10 or PPCU 2,3 line 3: PPLD 11,12,13,14 or PPCU 0,1 Bits 0-7: mask of outgoing PCM 8 Mb/s lines with comparison alarm (lines 16-23); bits 815: not used. The correspondence between lines and LICD is the same as the word jjjj mask of outgoing PCM 8 Mb/s lines with comparison alarm (lines 0-15). See previous word. Bit 0: Timing alarm flag of SN16; bit 1: ubex bus parity alarm flag of SN16 (data and/or address); bit 2: cyclic test alarm (SN16); bit 3: internal generic alarm; bit 4: alarm on ctrl G. A.; bit 5: alarm on input G. A.; bit 6: alarm on output G. A.; bit 7: fifo alarm; bits 8-15: not used.

iiii =

jjjj =

kkkk = llll =

mmmm = nnnn = oooo =

##StartSpecProbl##
Specific Problems = 342 SNAP PERMANENT FAILURE

Event Type = EQUIPMENT FAILURE EVENT Severity = MAJOR Proposed Repair Actions = 4 TEST THE ADDRESSED CARD(S)

A30808-X3247-K240-3-7619

43

Outputs OML:BSC

Base Station Controller

Originator = 4200 MDHNWABAF, 4202 MDHNWDCSC, 4205 MDHNWDCAL, 4207 MDHNWDCSS, 4250 MDHNWDD08 A permanent fault has been detected on the SNAP of the affected network copy. More details can be found in the other information (see below).
aaaa = bbbb = (Developer oriented) Source code line where the HW fault has been detected by the device driver Internal SW code error. The possible values are: 0=>Undefined HW error 1=>Loop test failed 2=>Bus parity error 3=>HW alarm active 5=>Alarm forcing failure 6=>CRC error (only PLLH) 7=>Wrong state of communication protocol (only PLLH) 8=>Time out during HW operation 0x11=>Unexpected state of HW 0x1A=>Invalid card type 0x1D=>Overflow of UBEX interrupts 0x1E=>NMI arisen while accessing HW affected device (it must be consistent with the error identity and the originator). The possible values are: 0: unknown 5: SNAP (Developer oriented) Originator which identifies the high level source file which has detected the failure (Developer oriented) Code line of the high level source file. Dump of the ubex alarm register. The following codes can be logically OR-ed: 0x1 (bit 0): Address parity error 0x2 (bit1): Data parity error 0x4 (bit 2) Chip select error Versions of the 2 PLLH (high byte): PLLH0 bit 8 .. 11; PLLH1 bit 12 .. 15. Value of the pllh alarm register (high byte). The following codes can be logically OR-ed: 0x1 (bit 0): If this bit is set, the PLLH is distributing its own clock signal, otherwise it is distributing the clock of the other PLLH 0x2 (bit 1): the input external synchronism is missing 0x4 (bit 2): the output clock is missing 0x8 (bit 3): the input external source to be measured to is missing 0x10 (bit 4): the PLLH is not synchronized with the other PLLH 0x20 (bit 5): address parity alarm on UBEX bus 0x40 (bit 6): data parity alarm on UBEX bus 0x80 (bit 7): watch dog alarm on the local processor Internal FW code of the PLLH (low byte) 0x1=>VCXO voltage out of range 0x2=>PLL unlocked 0x3=>Excessive jitter on synchronization source 0x4=>absence of the synchronization source 0x5=>last command from MPCC has not been understood 0x6=>VCXO voltage in the pre-alarm range 0x7=>interruption of the synchronization source 0x8=>eprom checksum failure 0x9=>fault on the DAC or on the ADC 0xA=>fault in the phase comparator0xD=>CIOA fault (only PLLH V2) Dump of the alarm registers of the input block of SN (low byte). The following codes can be logically OR-ed: 0x1 (bit 0): UBEX address parity error 0x2 (bit 1): UBEX data parity error 0x4 (bit 2): PCM parity alarm from LICD 0x8 (bit 3): PCM parity alarm from PPXX (valid only if input lines are configured at 2Mb/s) 0x10 (bit 4): Parity address/data alarm on the CRAM 0x20 (bit 5): Timing/Re-Route alarm 0x40 (bit 6): No clock alarm 0x80 (bit 7): No sync alarm

cccc =

dddd = eeee = ffff =

gggg =

hhhh =

44

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
Dump of the alarm registers of the control block of SN (high byte). The following codes can be logically OR-ed: 0x1 (bit 0): UBEX address parity error 0x2 (bit 1): UBEX data parity error 0x4 (bit 2): PLLH alarm 0x8 (bit 3): FIFO error; 0x10 (bit 4): Wrong parity inside the control RAM 0x20 (bit 5): Internal timing alarm 0x40 (bit 6): Lack of clock to control gate array 0x80 (bit 7): Lack of synchronism to the control gate array Low byte: not meaninigful. High byte: dump of the alarm register of the output block of SN. The following codes can be logically OR-ed: 0x1 (bit 0): UBEX address parity error 0x2 (bit 1): UBEX data parity error 0x4 (bit 2): parity error on parallel bus 0x8 (bit 3): PCM parity error from LICD 0x10 (bit 4): Wong parity inside the control RAM 0x20 (bit 5): Internal timing re-route alarm 0x40 (bit 6): Lack of clock to input gate array 0x80 (bit 7): Lack of synchronism to the output gate array mask of the alarmated incoming PCM 8 Mb/s lines 0..15. The lines are connected in this way; lines 0..3 => LICDS-0 lines 4..7 => LICD-0 lines 8..11 => LICD-1 lines 12..15 => LICD-2 mask of the alarmated incoming PCM 8 Mb/s lines 16..31. The lines are connected in this way; lines 16..19 => LICD-3 lines 20..23 => LICD-4 lines 24..27 => LICD-5 lines 28..31 => LICD-6 mask of the alarmated incoming PCM 8 Mb/s lines 32..43. The lines are connected in this way; lines 32..35 => LICD-7 lines 36..39 => LICD-8 lines 40..43 => LICDS-1 lines 44..47 => NOT USED mask of the alarmated incoming PCM 8 Mb/s lines 48..55 coming from PPXX. The lines are connected in this way; lines 48..49 => PPXL 0..1 lines 50 ..55 => PPXU 0..5 lines 56..59 => NOT USED comparison alarm on incoming PCM lines 0..15 Bit 0: Timing alarm flag of SN; bit 1: ubex bus parity alarm flag of SN (data and/or address); bit 2: cyclic test alarm; bit 3: internal generic alarm; bit 4: alarm on ctrl G. A.; bit 5: alarm on input G. A.; bit 6: alarm on output G. A.; bit 7: fifo alarm; bits 8-15: not used.

iiii =

jjjj =

kkkk =

llll =

mmmm =

nnnn = oooo =

##StartSpecProbl##
Specific Problems = 158 TOO MANY UBEX INTERRUPT

Event Type = EQUIPMENT FAILURE EVENT Severity = WARNING Proposed Repair Actions = 5 SEE THE PROPOSED ACTION IN THE MANUAL

Originator = 4205 MDHNWDCAL


A30808-X3247-K240-3-7619 45

Outputs OML:BSC

Base Station Controller

A threshold of a maximum number of ubex interrupts has been reached during a fixed time interval (tipically 10000 interrupts in 100 seconds). This means that the ubex interrupts are so many as to keep dangerously busy the CPU real time resources. So this error is always associated to another error (UBEX_PERMANENT_FAILURE or similar) that puts the network copy in disabled state.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = code source line where error has been called number of occurred interrupt in the last observation period (see next word) value of the observation time unit (expressed in second) percentage of occurred interrupts due to PLLH percentage of occurred interrupts due to SN64, SN16 or SNAP percentage of occurred interrupts due to PPCC or PPLD percentage of occurred interrupts that cannot be surely attributed to any device internal time stamp (in seconds since last fill init) of the beginning of the last observation period internal time stamp (in second since last full init) of the last occurred interrupt not used not used not used not used not used not used

##StartSpecProbl##
Specific Problems = 161 PERMANENT COMPARISON ALARM ON SN

Event Type = EQUIPMENT FAILURE EVENT Severity = MINOR Proposed Repair Actions = 17 COLLECT INFO FOR ASSISTANCE (SEE MANUAL)

Originator = 4205 MDHNWDCAL On the SN there is a permanent comparison alarm. This means that there can be a difference between the 2 bit streams outgoing from the 2 copies of matrix. Generally, this alarm allows to detect SW problems (for which the network connection are not aligned on the 2 copies); anyway, when this error is issued, any possible SW cause for this alarm has been removed, and probably this is an inconsistent alarm due to HW problems. So the comparison alarm is disabled, to avoid that the fault detection is continuously busy to handle this alarm. In this way, however, a powerful diagnostic tool is no more available, and this is the reason why the NTW goes in degraded state. Later on, the device handler will perform a periodical check to see if this alarm can be enabled again, clearing this error.
aaaa = bbbb = cccc = dddd eeee ffff gggg hhhh iiii = = = = = = code source line where error occurred mask bit corresponding to the alarmed PCM lines from 32 to 59 (only for SNAP card) mask bit corresponding to the alarmed PCM lines from 0 to 31 (for SN64 or SN16 first 24 bits are significant). not used not used not used not used not used not used

46

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = = = not used not used not used not used not used not used

jjjj kkkk llll mmmm nnnn oooo

##StartSpecProbl##
Specific Problems = 163 WRONG PCM PARITY FROM LICD

Event Type = EQUIPMENT FAILURE EVENT Severity = MINOR Proposed Repair Actions = 0 NWK, LICD, FLAT CABLE PROBLEM (SEE MANUAL)

Originator = 4400 MDHLCDCDE A permanent PCM parity alarm has been detected on SN due to a bad signal coming from LICD.
aaaa bbbb cccc dddd eeee = = = = = Developer reserved: code line number where error is emitted Error originator where error was detected Developer reserved: code line number where error was detected Developer reserved: type of error occurred Developer reserved: cmdreg (low byte); type of licd (high byte): 0->DTLP; 1->QTLP V1; 2->QTLP V2. Mask of card line relays status (1=closed,0=open) Mask of card mate relays status (1=closed,0=open) Mask of physical pcm lines cutover status (1=line under cutover,0=line not cutovered) Ubex copy active (low byte); type of pcm working mode (high byte): 24(16h)->PCM24 ; 32(20h)->PCM32. Developer reserved: "hwchk": it should be 0x82, otherwise, a FW error has occurred Developer reserved: "cmdecho": value of the last command sent by MPCC to the FW of LICD Developer reserved: fwresp[0] Developer reserved: fwresp[1] Developer reserved: fwresp[2] Developer reserved: fwresp[3]

ffff gggg hhhh iiii

= = = =

jjjj = kkkk = llll mmmm nnnn oooo = = = =

##StartSpecProbl##
Specific Problems = 171 DISK NOT FORMATTED

Event Type = EQUIPMENT FAILURE EVENT Severity = MAJOR Proposed Repair Actions = 7 SEE THE AUTOMATIC DIAGNOSTIC TEST RESULT

A30808-X3247-K240-3-7619

47

Outputs OML:BSC

Base Station Controller

Originator = 1 MOSFSIO0, 2 MOSFSIO1 Disk isn't formatted. Only aaaa value has importance.
aaaa bbbb cccc dddd eeee ffff = = = = = = DiskFormatted Duam Field CardStatus " " StbyCardStatus " " Operationcode " " FileSystemBusy " " OperationReturnCode " " 0000 No Error 0003 Too Many Fs Clients 0005 Disk Full 0013 File In Use 0016 File Not Found 0018 Directory Not Found 0020 Cross Copy In Progress 1100 Both Disk Copies Out Of Service Other: for designer use only. FileIdentifier Duam Field Miscomparison " " LinkStatus " " DiskFreeSpace " " DiagResponse " " FileSystemSemaphore FSDataSemaphore MaintenaceSemaphore CmdInProegressSemaphore

gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

= = = = = = = = =

##StartSpecProbl##
Specific Problems = 186 IXLT SOFTWARE BAD RESTART

Event Type = EQUIPMENT FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 4451 MDHIXDCMC this error occurs when the IXLT SW sends a NACK to the RESTART command
aaaa = bbbb = cccc = the line number of the source module the command result coming from the IXLT I/O task the signal subtype of the RTE header coming from the IXLT I/O task 1 = T42_IXLT_FAILURE (IXLT not available) 2 = T42_IXLT_SEMLOCKED (IXLT DUAM semaphore locked) 3 = T42_IXLT_CMD_OUTSTANDING (IXLT SW busy) 4 = T42_IXLT_TIMEOUT (IXLT does not answer in sufficient time) 6 = T42_IXLT_CMDERROR (bad command sent to IXLT SW by DH) the state of the IXLT automata the NACK cause coming from IXLT SW a flag indicating if the IXLT must be reset (1) or not(0) not used

dddd eeee ffff gggg

= = = =

48

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = = = = = not used not used not used not used not used not used not used not used

hhhh iiii jjjj kkkk llll mmmm nnnn oooo

##StartSpecProbl##
Specific Problems = 187 IXLT SOFTWARE BAD COMMAND

Event Type = EQUIPMENT FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 4451 MDHIXDCMC this error occurs when the IXLT SW does not answer to the INIT, START or RESTART command.
aaaa = bbbb = cccc = the line number of the source module the command result coming from the IXLT I/O task the signal subtype of the RTE header coming from the IXLT I/O task 1 = T42_IXLT_FAILURE (IXLT not available) 2 = T42_IXLT_SEMLOCKED (IXLT DUAM semaphore locked) 3 = T42_IXLT_CMD_OUTSTANDING (IXLT SW busy) 4 = T42_IXLT_TIMEOUT (IXLT does not answer in sufficient time) 6 = T42_IXLT_CMDERROR (bad command sent to IXLT SW by DH) the state of the IXLT automata not used not used not used not used not used not used not used not used not used not used not used

dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

= = = = = = = = = = = =

Originator = 4451 MDHIXDCMC this error occurs when the IXLT, after the INIT or START command, does not work;
A30808-X3247-K240-3-7619 49

Outputs OML:BSC

Base Station Controller

particularly, the DUAM flag indicating the IXLT working state assumes a wrong value.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = the line number of the source module 0xFFFF the DUAM flag indicating the IXLT working state the state of the IXLT automata not used not used not used not used not used not used not used not used not used not used not used

##StartSpecProbl##
Specific Problems = 207 IXLT CARD CORRUPTED

Event Type = EQUIPMENT FAILURE EVENT Severity = MAJOR Proposed Repair Actions = 4 TEST THE ADDRESSED CARD(S)

Originator = 4450 MDHIXDCSA this error occurs when the control register of the IXLT was found corrupted during the periodical scan alarm.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = the number of the line of the source module the retry counter not used not used not used not used not used not used not used not used not used not used not used not used not used

50

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

##StartSpecProbl##
Specific Problems = 212 HARDWARE FAILURE DIAGNOSTIC REQUEST

Event Type = EQUIPMENT FAILURE EVENT Severity = MAJOR Proposed Repair Actions = 7 SEE THE AUTOMATIC DIAGNOSTIC TEST RESULT

Originator = 4305 MDH40IOSC This error occurs when a fault is issued from device handler of dk40. A System -info report supplies more information about the fault that have caused the error
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = module that generates the error Source code line of the module that generates the error not used not used not used not used not used not used not used not used not used not used not used not used not used

Originator = 4600 MDHPRDCDE The standby MEMT card has been found failed by the TDPC.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk = = = = = = = = = = = Line in the code where the error is issued. Code of the found error. Software item that recognized the error. Line in the software module where the error has been recognized. MEMT configuration on MPCC side. Not used. Not used. Not used. Not used. Not used. Not used.

A30808-X3247-K240-3-7619

51

Outputs OML:BSC
llll mmmm nnnn oooo = = = = Not used. Not used. Not used. Not used.

Base Station Controller

Originator = 4503 MDHXXDCSA This error is issued when PPCC (case a) or PPCU (case b) Device Handler or other fault detectors reveal a recoverable problem on a card.
aaaa = bbbb = cases a and b: number of source line where xxcuHwFault routine is called cases a and b: high byte: identifier of source item where problem was detected: 1 = DHXXDCCH; 2 = DHXXDCDE; 3 = DHXXDCEH; 4 = DHXXDCSA; 5 = DHXXDCSM; 6 = DHXXDCTH; 7 = DHXXDDDI; 8 = DHXXDDHD; 9 = DHXXGSUT; 10 = DHXXININ; 11 = DGHDXXDP; 12 = DHXXDDPU; low byte: error code: 0xA0 = alarm detected 0xA1 = failure of alarm forcing 0xA3 = failed writing operation on PPLD-MPCC HW interface 0xA4 = missing pointer to PPxx map (HW/SW interface) 0xD5 = Abic Problem detected by PPCU Agent 0xD6 = Gbic Problem detected by PPCU Agent 0xD7 = PCUC Problem detected by PPCU Agent case a: number of source line (instruction calling driver where fault is detected) case b: number of source line (driver detecting the fault) case a: high byte: identifier of source item calling involved driver; low byte: error code case b: high byte: identifier of source item calling involved driver; low byte: error code case a: number of source line (different from value in point aaaa only if xxcuHwFault routine is called for an error different from another problem already set) case b: number of source line (instruction calling driver where fault is detected) case a: high byte: identifier of source item calling involved driver; low byte: error code (values different from values in point bbbb only if xxcuHwFault routine is called for an error different from another problem already set) case b: (values different from values in point bbbb only if xxcuHwFault routine is called for an error different from another problem already set) high byte: identifier of source item calling involved driver; low byte: error code case a: bit mask of alarms not causing interrupts (high byte) and bit mask of masked UBEX alarms (low byte) case b: number of source line (different from value in point cccc only if xxcuHwFault routine is called for an error different from another problem already set) case a: power alarm (high byte) and bit mask of alarms causing interrupts (low byte) case b: alarms directly read on UBEX register on PPCU-MPCC DUAM (high byte) and stored copy of last values written on UBEX register (low byte) case a: trapped PCM channel data (high byte) and trapped PCM channel address (low byte) case b: last stored PPCU alarms (high byte) and SW semaphore on MPCC-PCUC DUAM (for commands to PCUC) (low byte) case a: trapped position of failed bit (if any) case b: first byte of command MPCC -> PCUC on DUAM case a: channel speed (high byte) and card operational parameters (low byte) case b: second byte of command MPCC -> PCUC on DUAM case a: first card programming register (high byte) and trap of loopback test done by FW (low byte) case b: SW semaphore for PCUC answer to MPCC (on DUAM) case a: state of transmission enabling (towards UBEX on PCM lines) (high byte) and second

cccc = dddd =

eeee =

ffff =

gggg =

hhhh =

iiii =

jjjj = kkkk = llll =

mmmm =

52

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
card programming register (low byte) case b: first byte of PCUC answer to MPCC (on DUAM) case a: not used case b: second byte of PCUC answer to MPCC (on DUAM) not used

nnnn = oooo =

Originator = 4504 MDHXXDCSM This error message is issued when a PCU Create command reveals a recoverable HW fault inside a PPCU card just created.
aaaa = bbbb = number of source line where xxcuHwFault routine is called high byte: identifier of source item where problem was detected: 1 = DHXXDCCH; 2 = DHXXDCDE; 3 = DHXXDCEH; 4 = DHXXDCSA; 5 = DHXXDCSM; 6 = DHXXDCTH; 7 = DHXXDDDI; 8 = DHXXDDHD; 9 = DHXXGSUT; 10 = DHXXININ; 11 = DGHDXXDP; 12 = DHXXDDPU; low byte: error code: 0xA0 = alarm detected 0xA1 = failure of alarm forcing 0xA3 = failed writing operation on PPLD-MPCC HW interface 0xA4 = missing pointer to PPxx map (HW/SW interface) 0xD5 = Abic Problem detected by PPCU Agent 0xD6 = Gbic Problem detected by PPCU Agent 0xD7 = PCUC Problem detected by PPCU Agent number of source line (driver detecting the fault) high byte: identifier of source item calling involved driver; low byte: error code number of source line (instruction calling driver where fault is detected) values different from values in point bbbb only if xxcuHwFault routine is called for an error different from another problem already set high byte: identifier of source item calling involved driver; low byte: error code number of source line (different from value in point cccc only if xxcuHwFault routine is called for an error different from another problem already set) alarms directly read on UBEX register on PPCU-MPCC DUAM (high byte) and stored copy of last values written on UBEX register (low byte) last stored PPCU alarms (high byte) and SW semaphore on MPCC-PCUC DUAM (for commands to PCUC) (low byte) first byte of command MPCC -> PCUC on DUAM second byte of command MPCC -> PCUC on DUAM SW semaphore for PCUC answer to MPCC (on DUAM) first byte of PCUC answer to MPCC (on DUAM) second byte of PCUC answer to MPCC (on DUAM) not used

cccc = dddd = eeee = ffff =

gggg = hhhh = iiii = jjjj kkkk llll mmmm nnnn oooo = = = = = =

Originator = 4509 MDHXXININ This error message is issued if a PPCC HW reset or other driver fails for recoverable problems during a dedicated time Init.
aaaa = bbbb = number of source line where xxcuHwFault routine is called high byte: identifier of source item where problem was detected:

A30808-X3247-K240-3-7619

53

Outputs OML:BSC

Base Station Controller

cccc = dddd = eeee = ffff =

gggg = hhhh iiii jjjj kkkk llll = = = = =

mmmm = nnnn = oooo =

1 = DHXXDCCH; 2 = DHXXDCDE; 3 = DHXXDCEH; 4 = DHXXDCSA; 5 = DHXXDCSM; 6 = DHXXDCTH; 7 = DHXXDDDI; 8 = DHXXDDHD; 9 = DHXXGSUT; 10 = DHXXININ; 11 = DGHDXXDP; 12 = DHXXDDPU; low byte: error code: 0xA0 = alarm detected 0xA1 = failure of alarm forcing 0xA3 = failed writing operation on PPLD-MPCC HW interface 0xA4 = missing pointer to PPxx map (HW/SW interface) 0xD5 = Abic Problem detected by PPCU Agent 0xD6 = Gbic Problem detected by PPCU Agent 0xD7 = PCUC Problem detected by PPCU Agent number of source line (instruction calling driver where fault is detected) high byte: identifier of source item calling involved driver; low byte: error code number of source line (different from value in point aaaa only if xxcuHwFault routine is called for an error different from another problem already set) high byte: identifier of source item calling involved driver; low byte: error code (values different from values in point bbbb only if xxcuHwFault routine is called for an error different from another problem already set) bit mask of alarms not causing interrupts (high byte) and bit mask of masked UBEX alarms (low byte) power alarm (high byte) and bit mask of alarms causing interrupts (low byte) trapped PCM channel data (high byte) and trapped PCM channel address (low byte) trapped position of failed bit (if any) channel speed (high byte) and card operational parameters (low byte) first card programming register (high byte) and trap of loopback test done by FW (low byte) state of transmission enabling (towards UBEX on PCM lines) (high byte) and second card programming register (low byte) not used not used

Originator = 4514 MDHXXLUSA This error is issued when PPXL Device Handler or other fault detectors reveal a recoverable problem on a card.
aaaa = bbbb = number of source line where xxcuHwFault routine is called high byte: identifier of source item where problem was detected: 14 = DHXXLUCH; 15 = DHXXLUDE; 16 = DHXXLUEH; 17 = DHXXLUSA; 18 = DHXXLUSM; 19 = DHXXLUTH; 7 = DHXXDDDI; 22 = DHXXDDLU; 20 = DHXXLUUT; 21 = DHXXLUIN; low byte: error code: LUALARM_ERR 0xA0 LUFORCE_ERR 0xA1 LUFAILED_DIAG 0xA2 LUWRITING_ERR 0xA3 LUMISSING_PPXX_PTR 0xA4 POWER_0_ALRM 0xA5 POWER_1_ALRM 0xA5 PLLH_0_MISSING_CLK_ALRM 0xA6 PLLH_1_MISSING_CLK_ALRM 0xA7 PLLH_0_SYNC_ALRM 0xA8 PLLH_1_SYNC_ALRM 0xA9 PARITY_ADDR_ALRM 0xAA PARITY_DATA_ALRM 0xAB SNAP_PARITY_ALRM_WIRE_D 0xAC SNAP_PARITY_ALRM_WIRE_P 0xAD TIMING_LOGIC_ALRM 0xAE

54

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
ACTIVE_PLLH_TIMING_ERR UBEX_PARITY_ERROR 0xAF 0xB0

cccc = dddd = eeee = ffff =

gggg = hhhh iiii jjjj kkkk llll = = = = =

mmmm = nnnn = oooo =

number of source line (instruction calling driver where fault is detected) high byte: identifier of source item calling involved driver; low byte: error code number of source line (different from value in point aaaa only if HwFault routine is called for an error different from another problem already set) high byte: identifier of source item calling involved driver; low byte: error code (values different from values in point bbbb only if xxcuHwFault routine is called for an error different from another problem already set) bit mask of alarms not causing interrupts (high byte) and bit mask of masked UBEX alarms (low byte) power alarm (high byte) and bit mask of alarms causing interrupts (low byte) trapped PCM channel data (high byte) and trapped PCM channel address (low byte) trapped position of failed bit (if any) channel speed (high byte) and card operational parameters (low byte) first card programming register (high byte) and trap of loopback test done by FW (low byte) state of transmission enabling (towards UBEX on PCM lines) (high byte) and second card programming register (low byte) not used not used

Originator = 4601 MDHPRDCMC The cross copy of the standby card, both for MPCC and TDPC, failed: the Memory Align Server unsuccessfully answered, due to FW problems during the cross copy.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Line in the code where this error is issued. The automa state. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

Originator = 4602 MDHPRDCSD This error is issued when the TDPC device handler receives an answer from load service
A30808-X3247-K240-3-7619 55

Outputs OML:BSC

Base Station Controller

with a card problem error code. In this case the affected card could be not really failed so the diagnostic has the purpose to verify it.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Line in the code where this error is issued. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

Originator = 4603 MDHPRDCUT The TDPC switch is not possible because of the failure of the initialization (BU_STDBY) on the standby card.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Line in the code where this error is issued. 1. Code of the occurred error. Software module in source field when the alarm checking has been activated. Software line in source field when the alarm checking has been activated. Status bits of TDPC (lower bits). Status bits of TDPC (higher bits). Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

Originator = 4603 MDHPRDCUT The TDPC switch is not possible because of the failure of the initialization (TASK_PRIME) on the active card.
aaaa = bbbb = Line in the code where this error is issued. 2.

56

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = = = = = = = = = = Code of the occurred error. Software module in source field when the alarm checking has been activated. Software line in source field when the alarm checking has been activated. Status bits of TDPC (lower bits). Status bits of TDPC (higher bits). Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

Originator = 4603 MDHPRDCUT The MPCC Hot Link faulted, either during initialization or alarm verification. The diagnostic on the circuitry of the active MPCC passed, so the standby card is considered faulted.
aaaa bbbb cccc dddd = = = = Line in the code where this error is issued. 3. Code of the occurred error. Software module in error field when the Hot Link initialization/alarm checking has been performed. Software line in error field when the Hot Link initialization/alarm checking has been performed. Error in the source field. Software module in source field when the Hot Link initialization/alarm checking has been activated. Software line in source field when the Hot Link initialization/alarm checking has been performed. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

eeee = ffff = gggg = hhhh = iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = =

Originator = 4603 MDHPRDCUT The TDPC Hot Link faulted, either during initialization or alarm verification. The diagnostic on the circuitry of the active TDPC passed, so the standby card is considered faulted.
aaaa = Line in the code where this error is issued.

A30808-X3247-K240-3-7619

57

Outputs OML:BSC
bbbb = cccc = dddd = eeee = ffff = gggg = hhhh = iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = =

Base Station Controller

4. Code of the occurred error. Software module in error field when the Hot Link initialization/alarm checking has been performed. Software line in error field when the Hot Link initialization/alarm checking has been performed. Error in the source field. Software module in source field when the Hot Link initialization/alarm checking has been activated. Software line in source field when the Hot Link initialization/alarm checking has been performed. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

Originator = 4604 MDHPRDCSM One HW failure took place while accessing MEMT card during maintenance operation.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Line in the code where this error is issued. Source input field (high). Source input field (low). Occurred error code (high). Occurred error code (low). MPCC alarm register. MPCC control point register. MPCC mask register. MPCC sense point register. zeroed. zeroed. zeroed. MEMT alarm register + memory boundary register. Memory small page selection reg. + memory large page selection reg. MEMT alarm mask register.

Originator = 4605 MDHPRININ The affected TDPC card could not be initialized (TASK_PRIME).
aaaa bbbb cccc dddd = = = = Line in the code where this error is issued. Code of the occurred error. Software line in error field when the alarm checking has been activated. Software module in error field when the alarm checking has been activated.

58

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = = = = = = = = MEMT cards configuration. MCR register of active MEMT copy. MEMT outage flag. Original TDPC status (high). Original TDPC status (low). Status bits of TDPC (lower bits). Status bits of TDPC (higher bits). Not used. Not used. Not used. Not used.

eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

Originator = 4606 MDHPRDCSA This error is issued by MPCC when the standby TDPC card is alarmed or failed to answer the audit.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Line in the code where this error is issued by MPCC. Cause input field (0 normal ,1 TDPC alarm detected). Status bits of TDPC (lower bits). Status bits of TDPC (higher bits). TDPC device handler internal status. Counter of sent messages. Counter of received messages. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

Originator = 4606 MDHPRDCSA This error is issued by MPCC when the standby MPCC is alarmed or failed to answer the audit.
aaaa bbbb cccc dddd eeee ffff gggg hhhh = = = = = = = = Line in the code where this error is issued. Software module where the error has been recognized. Line in the software module where the error has been found. Code of the occurred error. Software module in source field when the alarm checking has been activated. Software line in source field when the alarm checking has been activated. Device handler internal MPCC status. Cause input field.

A30808-X3247-K240-3-7619

59

Outputs OML:BSC
iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = Source of the MPCC alarm checking. Not used. Not used. Not used. Not used. Not used. Not used.

Base Station Controller

Originator = 4606 MDHPRDCSA This error is issued by MPCC when the active TDPC is found alarmed.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Line in the code where this error is issued by MPCC. Cause input field (0 normal, 1 TDPC alarm detected) Status bits of TDPC (lower bits) Status bits of TDPC (higher bits) TDPC device handler internal status. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

Originator = 4606 MDHPRDCSA This error is issued by MPCC when the active TDPC failed to answer to audit or the FW did not respond to commands.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn = = = = = = = = = = = = = = Line in the code where this error is issued by MPCC. Cause input field (0 normal, 1 TDPC alarm detected). Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

60

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
Not used.

oooo =

##StartSpecProbl##
Specific Problems = 213 HARDWARE FAILURE

Event Type = EQUIPMENT FAILURE EVENT Severity = MAJOR Proposed Repair Actions = 3 REPLACE THE ADDRESSED CARD

Originator = 4305 MDH40IOSC This error occurs when a failure is issued after a diagnostic request on the dk40 card.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Module that generates the error Source code line of the module that generates the error not used. not used. not used. not used. not used. not used. not used. not used. not used. not used. not used. not used. not used.

Originator = 4451 MDHIXDCMC this error occurs when the IXLT SW is being loaded and an HW error occurred while accessing the card.
aaaa = bbbb = cccc dddd eeee ffff gggg hhhh iiii = = = = = = = the line number of the source module the error code 11 = IXLT_BAD_SW_LOAD not used. not used. not used. not used. not used. not used. not used.

A30808-X3247-K240-3-7619

61

Outputs OML:BSC
jjjj kkkk llll mmmm nnnn oooo = = = = = = not used. not used. not used. not used. not used. not used.

Base Station Controller

Originator = 4451 MDHIXDCMC this error occurs when an NMI raised while accessing the card.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = the line number of the source module additional info provided by NMI handler additional info provided by NMI handler additional info provided by NMI handler additional info provided by NMI handler additional info provided by NMI handler additional info provided by NMI handler additional info provided by NMI handler additional info provided by NMI handler additional info provided by NMI handler additional info provided by NMI handler additional info provided by NMI handler additional info provided by NMI handler additional info provided by NMI handler additional info provided by NMI handler

Originator = 4451 MDHIXDCMC After the card reset, the system wait 10 seconds, then if the FW doesn't work yet correctly, the previous error is cleared and this alarm is issued .
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn = = = = = = = = = = = = = = the line number of the source module not used. not used. not used. not used. not used. not used. not used. not used. not used. not used. not used. not used. not used.

62

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
not used.

oooo =

Originator = 4453 MDHIXININ this error occurs when the IXLT card is being initialized and an HW error happened.
aaaa = bbbb = the line number of the source module error code 1 = IXLT_NOT_IN_FRAME 2 = IXLT_LOCAL_DUAM_NOT_INITIALIZED 3 = IXLT_CBC_DUAM_NOT_INITIALIZED 4 = IXLT_NOT_READY 5 = IXLT_DUAM_NOT_RESET 6 = IXLT_WRONG_DUAM_RESET not used. not used. not used. not used. not used. not used. not used. not used. not used. not used. not used. not used. not used.

cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

= = = = = = = = = = = = =

Originator = 4457 MDHIXDCSM this error occurs when the IXLT card is being put in service and an HW error happened.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = the line number of the source module not used. not used. not used. not used. not used. not used. not used. not used. not used. not used. not used. not used. not used. not used.

A30808-X3247-K240-3-7619

63

Outputs OML:BSC

Base Station Controller

Originator = 4503 MDHXXDCSA This error is issued when a severe HW problem is detected by PPCC/PPCU Device Handler or other fault detectors on a card (case a = PPCC; case b = PPCU).
aaaa = bbbb = cases a and b: number of source line where xxcuHwFault routine is called cases a and b: high byte: identifier of source item where problem was detected: 1 = DHXXDCCH; 2 = DHXXDCDE; 3 = DHXXDCEH; 4 = DHXXDCSA; 5 = DHXXDCSM; 6 = DHXXDCTH; 7 = DHXXDDDI; 8 = DHXXDDHD; 9 = DHXXGSUT; 10 = DHXXININ; 11 = DGHDXXDP; 12 = DHXXDDPU; low byte: error code: 0xE0 = problem detected by UBEX Interrupt Handler 0xE1 = problem detected by NMI Handler 0xE2 = card reset failure (FW self-test problem) 0xE3 = loop-back test failure 0xE4 = unexpected NMI 0xE5 = Abic severe problem (detected by PPCU Agent) 0xE6 = Gbic severe problem (detected by PPCU Agent) 0xE7 = PCUC severe problem (detected by PPCU Agent) case a: number of source line (instruction calling driver where fault is detected) case b: number of source line (driver detecting the fault) case a: high byte: identifier of source item calling involved driver; low byte: error code case b: high byte: identifier of source item calling involved driver; low byte: error code case a: number of source line (different from value in point aaaa only if xxcuHwFault routine is called for an error different from another problem already set) case b: number of source line (instruction calling driver where fault is detected) case a: high byte: identifier of source item calling involved driver; low byte: error code (values different from values in point bbbb only if xxcuHwFault routine is called for an error different from another problem already set) case b: (values different from values in point bbbb only if xxcuHwFault routine is called for an error different from another problem already set) high byte: identifier of source item calling involved driver; low byte: error code case a: bit mask of alarms not causing interrupts (high byte) and bit mask of masked UBEX alarms (low byte) case b: number of source line (different from value in point cccc only if xxcuHwFault routine is called for an error different from another problem already set) case a: power alarm (high byte) and bit mask of alarms causing interrupts (low byte) case b: alarms directly read on UBEX register on PPCU-MPCC DUAM (high byte) and stored copy of last values written on UBEX register (low byte) case a: trapped PCM channel data (high byte) and trapped PCM channel address (low byte) case b: last stored PPCU alarms (high byte) and SW semaphore on MPCC-PCUC DUAM (for commands to PCUC) (low byte) case a: trapped position of failed bit (if any) case b: first byte of command MPCC -> PCUC on DUAM case a: channel speed (high byte) and card operational parameters (low byte) case b: second byte of command MPCC -> PCUC on DUAM case a: first card programming register (high byte) and trap of loopback test done by FW (low byte) case b: SW semaphore for PCUC answer to MPCC (on DUAM) case a: state of transmission enabling (towards UBEX on PCM lines) (high byte) and second card programming register (low byte) case b: first byte of PCUC answer to MPCC (on DUAM) case a: not used case b: second byte of PCUC answer to MPCC (on DUAM)

cccc = dddd =

eeee =

ffff =

gggg =

hhhh =

iiii =

jjjj = kkkk = llll =

mmmm =

nnnn =

64

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
not used

oooo =

Originator = 4504 MDHXXDCSM This error message is issued when a PCU Create command reveals a severe HW fault inside a PPCU card just created.
aaaa = bbbb = number of source line where xxcuHwFault routine is called high byte: identifier of source item where problem was detected: 1 = DHXXDCCH; 2 = DHXXDCDE; 3 = DHXXDCEH; 4 = DHXXDCSA; 5 = DHXXDCSM; 6 = DHXXDCTH; 7 = DHXXDDDI; 8 = DHXXDDHD; 9 = DHXXGSUT; 10 = DHXXININ; 11 = DGHDXXDP; 12 = DHXXDDPU; low byte: error code: 0xE0 = problem detected by UBEX Interrupt Handler 0xE1 = problem detected by NMI Handler 0xE2 = card reset failure (FW self-test problem) 0xE3 = loop-back test failure 0xE4 = unexpected NMI 0xE5 = Abic severe problem (detected by PPCU Agent) 0xE6 = Gbic severe problem (detected by PPCU Agent) 0xE7 = PCUC severe problem (detected by PPCU Agent) number of source line (driver detecting the fault) high byte: identifier of source item calling involved driver; low byte: error code number of source line (instruction calling driver where fault is detected) values different from values in point bbbb only if xxcuHwFault routine is called for an error different from another problem already set high byte: identifier of source item calling involved driver; low byte: error code number of source line (different from value in point cccc only if xxcuHwFault routine is called for an error different from another problem already set) alarms directly read on UBEX register on PPCU-MPCC DUAM (high byte) and stored copy of last values written on UBEX register (low byte) last stored PPCU alarms (high byte) and SW semaphore on MPCC-PCUC DUAM (for commands to PCUC) (low byte) first byte of command MPCC -> PCUC on DUAM second byte of command MPCC -> PCUC on DUAM SW semaphore for PCUC answer to MPCC (on DUAM) first byte of PCUC answer to MPCC (on DUAM) second byte of PCUC answer to MPCC (on DUAM) not used

cccc = dddd = eeee = ffff =

gggg = hhhh = iiii = jjjj kkkk llll mmmm nnnn oooo = = = = = =

Originator = 4509 MDHXXININ This error message is issued if a PPCC HW reset or other driver fails for severe reasons during a dedicated time Init.
aaaa = bbbb = number of source line where xxcuHwFault routine is called high byte: identifier of source item where problem was detected: 1 = DHXXDCCH; 2 = DHXXDCDE; 3 = DHXXDCEH; 4 = DHXXDCSA; 5 = DHXXDCSM; 6 = DHXXDCTH; 7 = DHXXDDDI; 8 = DHXXDDHD; 9 = DHXXGSUT; 10 = DHXXININ; 11 = DGHDXXDP; 12 = DHXXDDPU;

A30808-X3247-K240-3-7619

65

Outputs OML:BSC

Base Station Controller

cccc = dddd = eeee = ffff =

gggg = hhhh iiii jjjj kkkk llll = = = = =

mmmm = nnnn = oooo =

low byte: error code: 0xE0 = problem detected by UBEX Interrupt Handler 0xE1 = problem detected by NMI Handler 0xE2 = card reset failure (FW self-test problem) 0xE3 = loop-back test failure 0xE4 = unexpected NMI number of source line (instruction calling driver where fault is detected) high byte: identifier of source item calling involved driver; low byte: error code number of source line (different from value in point aaaa only if xxcuHwFault routine is called for an error different from another problem already set) high byte: identifier of source item calling involved driver; low byte: error code (values different from values in point bbbb only if xxcuHwFault routine is called for an error different from another problem already set) bit mask of alarms not causing interrupts (high byte) and bit mask of masked UBEX alarms (low byte) power alarm (high byte) and bit mask of alarms causing interrupts (low byte) trapped PCM channel data (high byte) and trapped PCM channel address (low byte) trapped position of failed bit (if any) channel speed (high byte) and card operational parameters (low byte) first card programming register (high byte) and trap of loopback test done by FW (low byte) state of transmission enabling (towards UBEX on PCM lines) (high byte) and second card programming register (low byte) not used not used

Originator = 4514 MDHXXLUSA This error is issued when a severe HW problem is detected by PPXL Device Handler or other fault detectors on a card.
aaaa = bbbb = number of source line where HwFault routine is called high byte: identifier of source item where problem was detected: 14 = DHXXLUCH; 15 = DHXXLUDE; 16 = DHXXLUEH; 17 = DHXXLUSA; 18 = DHXXLUSM; 19 = DHXXLUTH; 7 = DHXXDDDI; 22 = DHXXDDLU; 20 = DHXXLUUT; 21 = DHXXLUIN; low byte: error code: LUKILL_BY_UBEX 0xE0 LUKILL_BY_NMI 0xE1 LUUNSUCC_RESET 0xE2 LULOOP_ERR 0xE3 LUNMI_ERR 0xE4 number of source line (instruction calling driver where fault is detected) high byte: identifier of source item calling involved driver; low byte: error code number of source line (different from value in point aaaa only if HwFault routine is called for an error different from another problem already set) high byte: identifier of source item calling involved driver; low byte: error code (values different from values in point bbbb only if xxcuHwFault routine is called for an error different from another problem already set) bit mask of alarms not causing interrupts (high byte) and bit mask of masked UBEX alarms (low byte) power alarm (high byte) and bit mask of alarms causing interrupts (low byte) trapped PCM channel data (high byte) and trapped PCM channel address (low byte) trapped position of failed bit (if any)

cccc = dddd = eeee = ffff =

gggg = hhhh = iiii = jjjj =

66

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
channel speed (high byte) and card operational parameters (low byte) first card programming register (high byte) and trap of loopback test done by FW (low byte) state of transmission enabling (towards UBEX on PCM lines) (high byte) and second card programming register (low byte) not used not used

kkkk = llll = mmmm = nnnn = oooo =

Originator = 4601 MDHPRDCMC An hardware failure has been detected on the affected card, no recovery is necessary because the failure location is sure.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Line in the code where the error has been recognized. If the affected card is PWRD or EPWR this field reports the automa state. If the affected card is PWRD or EPWR this field reports the event received by the DH. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

Originator = 4603 MDHPRDCUT The active TDPC card failed during the preliminary operation to initialize the card before the software load.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn = = = = = = = = = = = = = = Line in the code where the error report is issued. Code of the occurred error. Line in the software module where the error took place. Software module where the error took place. MEMT cards configuration. Active MEMT MCR . MEMT outage flag. Line in the code where the error has been recognized. Not used. Not used. Not used. Not used. Not used. Not used.

A30808-X3247-K240-3-7619

67

Outputs OML:BSC
oooo = Not used.

Base Station Controller

Originator = 4604 MDHPRDCSM An hardware failure has been detected on the MEMT card, no recovery is necessary because the failure location is sure, all the recovery actions have been peformed by the device handler.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn = = = = = = = = = = = = = = Line in the code where the error has been recognized. Source input field (high). Source input field (low). Occurred error code (high). Occurred error code (low). MPCC alarm register. MPCC control point register. MPCC mask register. MPCC sense point register. zeroed zeroed zeroed MEMT alarm register (low byte) + memory boundary register (high byte). Memory small page selection register (low byte) + memory large page selection register (high byte). MEMT alarm mask register.

oooo =

Originator = 4605 DHPRININ The TDPC restart failed.


aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Line in the code where the error report is issued. 2. Code of the occurred error. Software module where the error took place. Line in the software module where the error took place. MEMT cards configuration. Active MEMT MCR. MEMT outage flag. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

68

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Originator = 4605 DHPRININ The standby MPCC was found alarmed during its initialization.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Line in the code where the error report is issued. 1. The initialization level. The occurred error. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

##StartSpecProbl##
Specific Problems = 214 CARD RESERVED FOR TEST

Event Type = EQUIPMENT FAILURE EVENT Severity = MAJOR Proposed Repair Actions = 1 NO ACTION

Originator = 4304 MDH40IOSC This error occurs when diagnostic tests are requested on dk40 card
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Module that generates the error Source code line of the mnot usedodule that generates the error not used not used not used not used not used not used not used not used not used not used not used not used not used

A30808-X3247-K240-3-7619

69

Outputs OML:BSC

Base Station Controller

##StartSpecProbl##
Specific Problems = 215 CARD DIAGNOSTIC FAILED

Event Type = EQUIPMENT FAILURE EVENT Severity = MAJOR Proposed Repair Actions = 1 NO ACTION

Originator = 4202 MDHNWDCSC This error occurs when the scheduled diagnostic upon the NTW card failed, if the NTW was enabled before the test. No error is issued if the NTW was already failed before the test.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Source line of code where error has been issued not used not used not used not used not used not used not used not used not used not used not used not used not used not used

Originator = 4451 MDHIXDCMC this error occurs when the scheduled diagnostic upon the IXLT card failed.
aaaa = bbbb = cccc dddd eeee ffff gggg hhhh iiii jjjj = = = = = = = = the line number of the source module error code 10 = IXLT_UNDER_DIAG not used. not used. not used. not used. not used. not used. not used. not used.

70

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = = not used. not used. not used. not used. not used.

kkkk llll mmmm nnnn oooo

Originator = 4501 MDHXXDCDE A PPCC (case a) or PPCU (case b) Diagnostic Test failed.
aaaa = bbbb = case a: number of source line where error was found case b: number of source line where xxcuHwFault routine is called cases a and b: high byte: identifier of source item where problem was detected: 1 = DHXXDCCH; 2 = DHXXDCDE; 3 = DHXXDCEH; 4 = DHXXDCSA; 5 = DHXXDCSM; 6 = DHXXDCTH; 7 = DHXXDDDI; 8 = DHXXDDHD; 9 = DHXXGSUT; 10 = DHXXININ; 11 = DGHDXXDP; 12 = DHXXDDPU; low byte: error code: 0xa2 = diagnostic test failure case a: number of source line (calling driver where fault was detected) case b: number of source line (driver detecting the fault) cases a and b: high byte: identifier of source item calling involved driver; low byte: error code case a: number of source line (different from value in point aaaa only if xxcuHwFault routine is called for an error different from another problem already set) case b: number of source line (instruction calling driver where fault is detected) case a: high byte: identifier of source item calling involved driver; low byte: error code (values different from values in point dddd only if xxcuHwFault routine is called for an error different from another problem already set) case b: (values different from values in point bbbb only if xxcuHwFault routine is called for an error different from another problem already set) high byte: identifier of source item calling involved driver; low byte: error code case a: bit mask of alarms not causing interrupts (high byte) and bit mask of masked UBEX alarms (low byte) case b: number of source line (different from value in point cccc only if xxcuHwFault routine is called for an error different from another problem already set) case a: power alarm (high byte) and bit mask of alarms causing interrupts (low byte) case b: alarms directly read on UBEX register on PPCU-MPCC DUAM (high byte) and stored copy of last values written on UBEX register (low byte) case a: trapped PCM channel data (high byte) and trapped PCM channel address (low byte) case b: last stored PPCU alarms (high byte) and SW semaphore on MPCC-PCUC DUAM (for commands to PCUC) (low byte) case a: trapped position of failed bit (if any) case b: first byte of command MPCC -> PCUC on DUAM case a: channel speed (high byte) and card operational parameters (low byte) case b: second byte of command MPCC -> PCUC on DUAM case a: first card programming register (high byte) and trap of loopback test done by FW (low byte) case b: SW semaphore for PCUC answer to MPCC (on DUAM) case a: state of transmission enabling (towards UBEX on PCM lines) (high byte) and second card programming register (low byte) case b: first byte of PCUC answer to MPCC (on DUAM) case a: not used case b: second byte of PCUC answer to MPCC (on DUAM) not used

cccc = dddd =

eeee =

ffff =

gggg =

hhhh =

iiii =

jjjj = kkkk = llll =

mmmm =

nnnn = oooo =

A30808-X3247-K240-3-7619

71

Outputs OML:BSC

Base Station Controller

Originator = 4512 MDHXXLUDE this error occours when a PPXL Diagnostic fail
aaaa = bbbb = cccc = dddd = eeee = ffff = source code line high byte: identifier of source item where problem was detected: 15 = DHXXLUDE; source code line (intrunction calling driver where fault is decteted) high byte: identifier of source item calling involved driver; low byte: error code number of source line (different from value in point aaaa only if HwFault routine is called for an error different from another problem already set) high byte: identifier of source item calling involved driver; low byte: error code (values different from values in point bbbb only if xxcuHwFault routine is called for an error different from another problem already set) SupervisionAlarm and Alarm Register Mask Alarm Register(hight byte) and PPXX conf Register (low) SupervisionAlarm(hight byte) and Alarm Register(low) Pentium Reset Register Power Supply Register first Byte of command memory area first Byte of responce memory area not used not used

gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

= = = = = = = = =

Originator = 4604 MDHPRDCSM The requested diagnostic upon the affected card failed.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Line in the code where the error notification is formatted. Status manager status internal to the device handler (high). Status manager status internal to the device handler (low). Result of the diagnostic. Force parameter. Test termination value. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

72

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

##StartSpecProbl##
Specific Problems = 217 PERIPHERAL CARD FAILURE DIAGNOSTIC REQUIRED

Event Type = EQUIPMENT FAILURE EVENT Severity = MINOR Proposed Repair Actions = 7 SEE THE AUTOMATIC DIAGNOSTIC TEST RESULT

Originator = 4503 MDHXXDCSA This error message is issued when a recoverable or not severe fault takes place on a PPLD card.
aaaa = bbbb = number of source line high byte: identifier of source item where problem was detected: 1 = DHXXDCCH; 2 = DHXXDCDE; 3 = DHXXDCEH; 4 = DHXXDCSA; 5 = DHXXDCSM; 6 = DHXXDCTH; 7 = DHXXDDDI; 8 = DHXXDDHD; 9 = DHXXGSUT; 10 = DHXXININ; 11 = DGHDXXDP; 12 = DHXXDDPU; low byte: error code: 0xA0 = alarm detected 0xA1 = failure of alarm forcing 0xA3 = failed writing operation on PPLD-MPCC HW interface 0xA4 = missing pointer to PPxx map (HW/SW interface) 0xD5 = Abic Problem detected by PPCU Agent 0xD6 = Gbic Problem detected by PPCU Agent 0xD7 = PCUC Problem detected by PPCU Agent number of source line (instruction calling driver where fault is detected) high byte: identifier of source item calling involved driver; low byte: error code number of source line (different from value in point aaaa only if xxcuHwFault routine is called for an error different from another problem already set) high byte: identifier of source item calling involved driver; low byte: error code (values different from values in point bbbb only if xxcuHwFault routine is called for an error different from another problem already set) bit mask of alarms not causing interrupts (high byte) and bit mask of masked UBEX alarms (low byte) power alarm (high byte) and bit mask of alarms causing interrupts (low byte) trapped PCM channel data (high byte) and trapped PCM channel address (low byte) trapped position of failed bit (if any) channel speed (high byte) and card operational parameters (low byte) first card programming register (high byte) and trap of loopback test done by FW (low byte) state of transmission enabling (towards UBEX on PCM lines) (high byte) and second card programming register (low byte) not used not used

cccc = dddd = eeee = ffff =

gggg = hhhh iiii jjjj kkkk llll = = = = =

mmmm = nnnn = oooo =

Originator = 4504 MDHXXDCSM

A30808-X3247-K240-3-7619

73

Outputs OML:BSC

Base Station Controller

This error message is issued if PPLD Create routine (Device Handler) detects a recoverable problem on involved card.
aaaa = bbbb = number of source line high byte: identifier of source item where problem was detected: 1 = DHXXDCCH; 2 = DHXXDCDE; 3 = DHXXDCEH; 4 = DHXXDCSA; 5 = DHXXDCSM; 6 = DHXXDCTH; 7 = DHXXDDDI; 8 = DHXXDDHD; 9 = DHXXGSUT; 10 = DHXXININ; 11 = DGHDXXDP; 12 = DHXXDDPU; low byte: error code: 0xA0 = alarm detected 0xA1 = failure of alarm forcing 0xA3 = failed writing operation on PPLD-MPCC HW interface 0xA4 = missing pointer to PPxx map (HW/SW interface) 0xD5 = Abic Problem detected by PPCU Agent 0xD6 = Gbic Problem detected by PPCU Agent 0xD7 = PCUC Problem detected by PPCU Agent number of source line (instruction calling driver where fault is detected) high byte: identifier of source item calling involved driver; low byte: error code number of source line (different from value in point aaaa only if xxcuHwFault routine is called for an error different from another problem already set) high byte: identifier of source item calling involved driver; low byte: error code (values different from values in point bbbb only if xxcuHwFault routine is called for an error different from another problem already set) bit mask of alarms not causing interrupts (high byte) and bit mask of masked UBEX alarms (low byte) power alarm (high byte) and bit mask of alarms causing interrupts (low byte) trapped PCM channel data (high byte) and trapped PCM channel address (low byte) trapped position of failed bit (if any) channel speed (high byte) and card operational parameters (low byte) first card programming register (high byte) and trap of loopback test done by FW (low byte) state of transmission enabling (towards UBEX on PCM lines) (high byte) and second card programming register (low byte) not used not used

cccc = dddd = eeee = ffff =

gggg = hhhh iiii jjjj kkkk llll = = = = =

mmmm = nnnn = oooo =

Originator = 4514 MDHXXLUSA This error message is issued when a recoverable or not severe fault takes place on a PPXU card.
aaaa = bbbb = number of source line where HwFault routine is called high byte: identifier of source item where problem was detected: 14 = DHXXLUCH; 15 = DHXXLUDE; 16 = DHXXLUEH; 17 = DHXXLUSA; 18 = DHXXLUSM; 19 = DHXXLUTH; 7 = DHXXDDDI; 22 = DHXXDDLU; 20 = DHXXLUUT; 21 = DHXXLUIN; low byte: error code: LUALARM_ERR 0xA0 LUFORCE_ERR 0xA1 LUFAILED_DIAG 0xA2 LUWRITING_ERR 0xA3 LUMISSING_PPXX_PTR 0xA4 POWER_0_ALRM 0xA5 POWER_1_ALRM 0xA5 PLLH_0_MISSING_CLK_ALRM 0xA6 PLLH_1_MISSING_CLK_ALRM 0xA7 PLLH_0_SYNC_ALRM 0xA8

74

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
PLLH_1_SYNC_ALRM 0xA9 PARITY_ADDR_ALRM 0xAA PARITY_DATA_ALRM 0xAB SNAP_PARITY_ALRM_WIRE_D 0xAC SNAP_PARITY_ALRM_WIRE_P 0xAD TIMING_LOGIC_ALRM 0xAE ACTIVE_PLLH_TIMING_ERR 0xAF UBEX_PARITY_ERROR 0xB0

cccc = dddd = eeee = ffff =

gggg = hhhh iiii jjjj kkkk llll = = = = =

mmmm = nnnn = oooo =

number of source line (instruction calling driver where fault is detected) high byte: identifier of source item calling involved driver; low byte: error code number of source line (different from value in point aaaa only if HwFault routine is called for an error different from another problem already set) high byte: identifier of source item calling involved driver; low byte: error code (values different from values in point bbbb only if xxcuHwFault routine is called for an error different from another problem already set) bit mask of alarms not causing interrupts (high byte) and bit mask of masked UBEX alarms (low byte) power alarm (high byte) and bit mask of alarms causing interrupts (low byte) trapped PCM channel data (high byte) and trapped PCM channel address (low byte) trapped position of failed bit (if any) channel speed (high byte) and card operational parameters (low byte) first card programming register (high byte) and trap of loopback test done by FW (low byte) state of transmission enabling (towards UBEX on PCM lines) (high byte) and second card programming register (low byte) not used not used

Originator = 4509 MDHXXININ This error message is issued when a PPLD device driver fails inside dedicated time Init routine because of a recoverable or not severe problem.
aaaa = bbbb = number of source line high byte: identifier of source item where problem was detected: 1 = DHXXDCCH; 2 = DHXXDCDE; 3 = DHXXDCEH; 4 = DHXXDCSA; 5 = DHXXDCSM; 6 = DHXXDCTH; 7 = DHXXDDDI; 8 = DHXXDDHD; 9 = DHXXGSUT; 10 = DHXXININ; 11 = DGHDXXDP; 12 = DHXXDDPU; low byte: error code: 0xA0 = alarm detected 0xA1 = failure of alarm forcing 0xA3 = failed writing operation on PPLD-MPCC HW interface 0xA4 = missing pointer to PPxx map (HW/SW interface) 0xD5 = Abic Problem detected by PPCU Agent 0xD6 = Gbic Problem detected by PPCU Agent 0xD7 = PCUC Problem detected by PPCU Agent number of source line (instruction calling driver where fault is detected) high byte: identifier of source item calling involved driver; low byte: error code number of source line (different from value in point aaaa only if xxcuHwFault routine is called for an error different from another problem already set) high byte: identifier of source item calling involved driver; low byte: error code (values different from values in point bbbb only if xxcuHwFault routine is called for an error different from another problem already set) bit mask of alarms not causing interrupts (high byte) and bit mask of masked UBEX alarms (low byte)

cccc = dddd = eeee = ffff =

gggg =

A30808-X3247-K240-3-7619

75

Outputs OML:BSC
hhhh iiii jjjj kkkk llll = = = = =

Base Station Controller

mmmm = nnnn = oooo =

power alarm (high byte) and bit mask of alarms causing interrupts (low byte) trapped PCM channel data (high byte) and trapped PCM channel address (low byte) trapped position of failed bit (if any) channel speed (high byte) and card operational parameters (low byte) first card programming register (high byte) and trap of loopback test done by FW (low byte) state of transmission enabling (towards UBEX on PCM lines) (high byte) and second card programming register (low byte) not used not used

##StartSpecProbl##
Specific Problems = 218 PERIPHERAL CARD HARDWARE FAILURE

Event Type = EQUIPMENT FAILURE EVENT Severity = MINOR Proposed Repair Actions = 3 REPLACE THE ADDRESSED CARD

Originator = 4400 MDHLCDCDE A test requested by operator has failed for the LICD. This error is not issued if the LICD was already disabled before the test.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Source line of code where the error is issued. not used not used not used not used not used not used not used not used not used not used not used not used not used not used

76

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Originator = 4503 MDHXXDCSA This error message is issued when PPLD fault detector (inside Device Controller) is managing a card severe problem.
aaaa = bbbb = number of source line high byte: identifier of source item where problem was detected: 1 = DHXXDCCH; 2 = DHXXDCDE; 3 = DHXXDCEH; 4 = DHXXDCSA; 5 = DHXXDCSM; 6 = DHXXDCTH; 7 = DHXXDDDI; 8 = DHXXDDHD; 9 = DHXXGSUT; 10 = DHXXININ; 11 = DGHDXXDP; 12 = DHXXDDPU; low byte: error code: 0xE0 = fault detected by UBEX Interrupt Handler 0xE1 = fault detected by NMI Handler 0xE2 = card reset failure (unsuccessful FW self-test) 0xE3 = failed loop-back 0xE4 = unexpected NMI detected by PPLD DH 0xE5 = Abic Fatal Problem detected by PPCU Agent 0xE6 = Gbic Fatal Problem detected by PPCU Agent 0xE7 = PCUC Fatal Problem detected by PPCU Agent number of source line (instruction calling driver where fault is detected) high byte: identifier of source item calling involved driver; low byte: error code number of source line (different from value in point aaaa only if xxcuHwFault routine is called for an error different from another problem already set) high byte: identifier of source item calling involved driver; low byte: error code (values different from values in point bbbb only if xxcuHwFault routine is called for an error different from another problem already set) bit mask of alarms not causing interrupts (high byte) and bit mask of masked UBEX alarms (low byte) power alarm (high byte) and bit mask of alarms causing interrupts (low byte) trapped PCM channel data (high byte) and trapped PCM channel address (low byte) trapped position of failed bit (if any) channel speed (high byte) and card operational parameters (low byte) first card programming register (high byte) and trap of loopback test done by FW (low byte) state of transmission enabling (towards UBEX on PCM lines) (high byte) and second card programming register (low byte) not used not used

cccc = dddd = eeee = ffff =

gggg = hhhh iiii jjjj kkkk llll = = = = =

mmmm = nnnn = oooo =

Originator = 4504 MDHXXDCSM This error message is issued when a PPLD Create command reveals a severe HW fault inside PPLD card just created
aaaa = bbbb = number of source line high byte: identifier of source item where problem was detected: 1 = DHXXDCCH; 2 = DHXXDCDE; 3 = DHXXDCEH; 4 = DHXXDCSA; 5 = DHXXDCSM; 6 = DHXXDCTH; 7 = DHXXDDDI; 8 = DHXXDDHD; 9 = DHXXGSUT; 10 = DHXXININ; 11 = DGHDXXDP; 12 = DHXXDDPU; low byte: error code: 0xE0 = fault detected by UBEX Interrupt Handler 0xE1 = fault detected by NMI Handler 0xE2 = card reset failure (unsuccessful FW self-test) 0xE3 = failed loop-back 0xE4 = unexpected NMI detected by PPLD DH 0xE5 = Abic Fatal Problem detected by PPCU Agent

A30808-X3247-K240-3-7619

77

Outputs OML:BSC

Base Station Controller

cccc = dddd = eeee = ffff =

gggg = hhhh iiii jjjj kkkk llll = = = = =

mmmm = nnnn = oooo =

0xE6 = Gbic Fatal Problem detected by PPCU Agent 0xE7 = PCUC Fatal Problem detected by PPCU Agent number of source line (instruction calling driver where fault is detected) high byte: identifier of source item calling involved driver; low byte: error code number of source line (different from value in point aaaa only if xxcuHwFault routine is called for an error different from another problem already set) high byte: identifier of source item calling involved driver; low byte: error code (values different from values in point bbbb only if xxcuHwFault routine is called for an error different from another problem already set) bit mask of alarms not causing interrupts (high byte) and bit mask of masked UBEX alarms (low byte) power alarm (high byte) and bit mask of alarms causing interrupts (low byte) trapped PCM channel data (high byte) and trapped PCM channel address (low byte) trapped position of failed bit (if any) channel speed (high byte) and card operational parameters (low byte) first card programming register (high byte) and trap of loopback test done by FW (low byte) state of transmission enabling (towards UBEX on PCM lines) (high byte) and second card programming register (low byte) not used not used

Originator = 4514 MDHXXLUSA This error message is issued when PPXU fault detector (inside Device Controller) is managing a card severe problem.
aaaa = bbbb = number of source line where HwFault routine is called high byte: identifier of source item where problem was detected: 14 = DHXXLUCH; 15 = DHXXLUDE; 16 = DHXXLUEH; 17 = DHXXLUSA; 18 = DHXXLUSM; 19 = DHXXLUTH; 7 = DHXXDDDI; 22 = DHXXDDLU; 20 = DHXXLUUT; 21 = DHXXLUIN; low byte: error code: LUKILL_BY_UBEX 0xE0 LUKILL_BY_NMI 0xE1 LUUNSUCC_RESET 0xE2 LULOOP_ERR 0xE3 LUNMI_ERR 0xE4 LU_ABIC_FATAL_PROBLEM 0xE5 LU_PCUC_FATAL_PROBLEM 0xE7 number of source line (instruction calling driver where fault is detected) high byte: identifier of source item calling involved driver; low byte: error code number of source line (different from value in point aaaa only if HwFault routine is called for an error different from another problem already set) high byte: identifier of source item calling involved driver; low byte: error code (values different from values in point bbbb only if xxcuHwFault routine is called for an error different from another problem already set) bit mask of alarms not causing interrupts (high byte) and bit mask of masked UBEX alarms (low byte) power alarm (high byte) and bit mask of alarms causing interrupts (low byte) trapped PCM channel data (high byte) and trapped PCM channel address (low byte) trapped position of failed bit (if any) channel speed (high byte) and card operational parameters (low byte)

cccc = dddd = eeee = ffff =

gggg = hhhh iiii jjjj kkkk = = = =

78

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
first card programming register (high byte) and trap of loopback test done by FW (low byte) state of transmission enabling (towards UBEX on PCM lines) (high byte) and second card programming register (low byte) not used not used

llll = mmmm = nnnn = oooo =

Originator = 4509 MDHXXININ This error message is issued if a PPLD HW reset or other driver fails for severe reasons during a dedicated time Init.
aaaa = bbbb = number of source line high byte: identifier of source item where problem was detected: 1 = DHXXDCCH; 2 = DHXXDCDE; 3 = DHXXDCEH; 4 = DHXXDCSA; 5 = DHXXDCSM; 6 = DHXXDCTH; 7 = DHXXDDDI; 8 = DHXXDDHD; 9 = DHXXGSUT; 10 = DHXXININ; 11 = DGHDXXDP; 12 = DHXXDDPU; low byte: error code: 0xE0 = fault detected by UBEX Interrupt Handler 0xE1 = fault detected by NMI Handler 0xE2 = card reset failure (unsuccessful FW self-test) 0xE3 = failed loop-back 0xE4 = unexpected NMI detected by PPLD DH 0xE5 = Abic Fatal Problem detected by PPCU Agent 0xE6 = Gbic Fatal Problem detected by PPCU Agent 0xE7 = PCUC Fatal Problem detected by PPCU Agent number of source line (instruction calling driver where fault is detected) high byte: identifier of source item calling involved driver; low byte: error code number of source line (different from value in point aaaa only if xxcuHwFault routine is called for an error different from another problem already set) high byte: identifier of source item calling involved driver; low byte: error code (values different from values in point bbbb only if xxcuHwFault routine is called for an error different from another problem already set) bit mask of alarms not causing interrupts (high byte) and bit mask of masked UBEX alarms (low byte) power alarm (high byte) and bit mask of alarms causing interrupts (low byte) trapped PCM channel data (high byte) and trapped PCM channel address (low byte) trapped position of failed bit (if any) channel speed (high byte) and card operational parameters (low byte) first card programming register (high byte) and trap of loopback test done by FW (low byte) state of transmission enabling (towards UBEX on PCM lines) (high byte) and second card programming register (low byte) not used not used

cccc = dddd = eeee = ffff =

gggg = hhhh iiii jjjj kkkk llll = = = = =

mmmm = nnnn = oooo =

##StartSpecProbl##
Specific Problems = 254 ENVA REGISTERS MISMATCH

Event Type = EQUIPMENT FAILURE EVENT Severity = MINOR


A30808-X3247-K240-3-7619 79

Outputs OML:BSC

Base Station Controller

Proposed Repair Actions = 1 NO ACTION

Originator = 4001 MDHACENSA The value of the alarm register of Enva of the Mpcc active copy is different from the value of the standby copy. Note that, in case of discrepancy, the Enva alarm is always issued .
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Developer reserved: code line number where error is emitted Reports the current state of all Sense Points of the active Mpcc copy. Reports the current state of all Sense Points of the standby Mpcc copy. Reports the number of the active Mpcc. not used. not used. not used. not used. not used. not used. not used. not used. not used. not used. not used.

##StartSpecProbl##
Specific Problems = 320 INTER PROCESSOR COMMUNICATION PROBLEM WITH TDPC

Event Type = EQUIPMENT_FAILURE_EVENT Severity = MAJOR Proposed Repair Actions = 7 SEE THE AUTOMATIC DIAGNOSTIC TEST RESULT

Originator = 4514 MDHXXLUSA This error is issued when a recoverable problem is detected on PPXL DUAM by Inter Processor Communication on TDPC side.
aaaa = bbbb = number of source line where HwFault routine is called high byte: identifier of source item where problem was detected: 14 = DHXXLUCH; 15 = DHXXLUDE; 16 = DHXXLUEH; 17 = DHXXLUSA; 18 = DHXXLUSM; 19 = DHXXLUTH; 7 = DHXXDDDI; 22 = DHXXDDLU; 20 =

80

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
DHXXLUUT; 21 = DHXXLUIN; low byte: error code: LU_CORRUPTED_DUAM 0x70 LU_MSG_NOT_AVAILABLE 0x71 LU_FULL_DUAM 0x72 LU_EMPTY_PARTITION 0x73 LU_SUCCESSFUL_WRITE 0x74 LU_EXTRACTED_CARD 0x75

cccc = dddd = eeee = ffff =

gggg = hhhh iiii jjjj kkkk llll = = = = =

mmmm = nnnn = oooo =

line (instruction calling driver where fault is detected) high byte: identifier of source item calling involved driver; low byte: error code number of source line (different from value in point aaaa only if HwFault routine is called for an error different from another problem already set) high byte: identifier of source item calling involved driver; low byte: error code (values different from values in point bbbb only if xxcuHwFault routine is called for an error different from another problem already set) bit mask of alarms not causing interrupts (high byte) and bit mask of masked UBEX alarms (low byte) power alarm (high byte) and bit mask of alarms causing interrupts (low byte) trapped PCM channel data (high byte) and trapped PCM channel address (low byte) trapped position of failed bit (if any) channel speed (high byte) and card operational parameters (low byte) first card programming register (high byte) and trap of loopback test done by FW (low byte) state of transmission enabling (towards UBEX on PCM lines) (high byte) and second card programming register (low byte) not used not used

Originator = 4503 MDHXXDCSA This error is issued when a recoverable problem is detected on PPCC (case a) or PPCU (case b) DUAM by Inter Processor Communication on TDPC side.
aaaa = bbbb = cases a and b: number of source line where xxcuHwFault routine is called cases a and b: high byte: identifier of source item where problem was detected: 1 = DHXXDCCH; 2 = DHXXDCDE; 3 = DHXXDCEH; 4 = DHXXDCSA; 5 = DHXXDCSM; 6 = DHXXDCTH; 7 = DHXXDDDI; 8 = DHXXDDHD; 9 = DHXXGSUT; 10 = DHXXININ; 11 = DGHDXXDP; 12 = DHXXDDPU; low byte: error code: 0x70 = Corrupted DUAM 0x71 = Message not available 0x72 = Full DUAM 0x73 = empty partition case a: number of source line (instruction calling driver where fault is detected) case b: number of source line (driver detecting the fault) case a: high byte: identifier of source item calling involved driver; low byte: error code case b: high byte: identifier of source item calling involved driver; low byte: error code case a: number of source line (different from value in point aaaa only if xxcuHwFault routine is called for an error different from another problem already set) case b: number of source line (instruction calling driver where fault is detected) case a: high byte: identifier of source item calling involved driver; low byte: error code (values different from values in point bbbb only if xxcuHwFault routine is called for an error different from another problem already set) case b: (values different from values in point bbbb only if xxcuHwFault routine is called for

cccc = dddd =

eeee =

ffff =

A30808-X3247-K240-3-7619

81

Outputs OML:BSC

Base Station Controller

gggg =

hhhh =

iiii =

jjjj = kkkk = llll =

mmmm =

nnnn = oooo =

an error different from another problem already set) high byte: identifier of source item calling involved driver; low byte: error code case a: bit mask of alarms not causing interrupts (high byte) and bit mask of masked UBEX alarms (low byte) case b: number of source line (different from value in point cccc only if xxcuHwFault routine is called for an error different from another problem already set) case a: power alarm (high byte) and bit mask of alarms causing interrupts (low byte) case b: alarms directly read on UBEX register on PPCU-MPCC DUAM (high byte) and stored copy of last values written on UBEX register (low byte) case a: trapped PCM channel data (high byte) and trapped PCM channel address (low byte) case b: last stored PPCU alarms (high byte) and SW semaphore on MPCC-PCUC DUAM (for commands to PCUC) (low byte) case a: trapped position of failed bit (if any) case b: first byte of command MPCC -> PCUC on DUAM case a: channel speed (high byte) and card operational parameters (low byte) case b: second byte of command MPCC -> PCUC on DUAM case a: first card programming register (high byte) and trap of loopback test done by FW (low byte) case b: SW semaphore for PCUC answer to MPCC (on DUAM) case a: state of transmission enabling (towards UBEX on PCM lines) (high byte) and second card programming register (low byte) case b: first byte of PCUC answer to MPCC (on DUAM) case a: not used case b: second byte of PCUC answer to MPCC (on DUAM) not used

##StartSpecProbl##
Specific Problems = 321 FATAL HARDWARE ERROR DETECTED BY TDPC

Event Type = EQUIPMENT_FAILURE_EVENT Severity = MAJOR Proposed Repair Actions = 1 NO ACTION

Originator = 4514 DHXXLUSA This error is issued when a severe problem is detected by Inter Processor Communication task on PPXL card.
aaaa = bbbb = number of source line where HwFault routine is called high byte: identifier of source item where problem was detected: 14 = DHXXLUCH; 15 = DHXXLUDE; 16 = DHXXLUEH; 17 = DHXXLUSA; 18 = DHXXLUSM; 19 = DHXXLUTH; 7 = DHXXDDDI; 22 = DHXXDDLU; 20 = DHXXLUUT; 21 = DHXXLUIN; low byte: error code: LU_ERR_NMI 0x50 LU_ERR_LOOP 0x51 LU_INACCESSIBLE_DUAM 0x52 LU_ALARMED_CARD 0x54 line (instruction calling driver where fault is detected) high byte: identifier of source item calling involved driver; low byte: error code number of source line (different from value in point aaaa only if HwFault routine is called for an error different from another problem already set) high byte: identifier of source item calling involved driver; low byte: error code (values different from values in point bbbb only if xxcuHwFault routine is called for an error

cccc = dddd = eeee = ffff =

82

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
different from another problem already set) bit mask of alarms not causing interrupts (high byte) and bit mask of masked UBEX alarms (low byte) power alarm (high byte) and bit mask of alarms causing interrupts (low byte) trapped PCM channel data (high byte) and trapped PCM channel address (low byte) trapped position of failed bit (if any) channel speed (high byte) and card operational parameters (low byte) first card programming register (high byte) and trap of loopback test done by FW (low byte) state of transmission enabling (towards UBEX on PCM lines) (high byte) and second card programming register (low byte) not used not used

gggg = hhhh iiii jjjj kkkk llll = = = = =

mmmm = nnnn = oooo =

Originator = 4503 MDHXXDCSA This error is issued when a severe problem is detected by Inter Processor Communication task on PPCC (case a) or PPCU (case b) DUAM (on TDPC side).
aaaa = bbbb = cases a and b: number of source line where xxcuHwFault routine is called cases a and b: high byte: identifier of source item where problem was detected: 1 = DHXXDCCH; 2 = DHXXDCDE; 3 = DHXXDCEH; 4 = DHXXDCSA; 5 = DHXXDCSM; 6 = DHXXDCTH; 7 = DHXXDDDI; 8 = DHXXDDHD; 9 = DHXXGSUT; 10 = DHXXININ; 11 = DGHDXXDP; 12 = DHXXDDPU; low byte: error code: 0x50 = NMI detected 0x51 = Loopback Test failure 0x52 = Inaccessible DUAM 0x53 = extracted or unreadable card 0x54 = alarmed card case a: number of source line (instruction calling driver where fault is detected) case b: number of source line (driver detecting the fault) case a: high byte: identifier of source item calling involved driver; low byte: error code case b: high byte: identifier of source item calling involved driver; low byte: error code case a: number of source line (different from value in point aaaa only if xxcuHwFault routine is called for an error different from another problem already set) case b: number of source line (instruction calling driver where fault is detected) case a: high byte: identifier of source item calling involved driver; low byte: error code (values different from values in point bbbb only if xxcuHwFault routine is called for an error different from another problem already set) case b: (values different from values in point bbbb only if xxcuHwFault routine is called for an error different from another problem already set) high byte: identifier of source item calling involved driver; low byte: error code case a: bit mask of alarms not causing interrupts (high byte) and bit mask of masked UBEX alarms (low byte) case b: number of source line (different from value in point cccc only if xxcuHwFault routine is called for an error different from another problem already set) case a: power alarm (high byte) and bit mask of alarms causing interrupts (low byte) case b: alarms directly read on UBEX register on PPCU-MPCC DUAM (high byte) and stored copy of last values written on UBEX register (low byte) case a: trapped PCM channel data (high byte) and trapped PCM channel address (low byte) case b: last stored PPCU alarms (high byte) and SW semaphore on MPCC-PCUC DUAM (for commands to PCUC) (low byte) case a: trapped position of failed bit (if any) case b: first byte of command MPCC -> PCUC on DUAM case a: channel speed (high byte) and card operational parameters (low byte)

cccc = dddd =

eeee =

ffff =

gggg =

hhhh =

iiii =

jjjj = kkkk =

A30808-X3247-K240-3-7619

83

Outputs OML:BSC
llll =

Base Station Controller

mmmm =

nnnn = oooo =

case b: second byte of command MPCC -> PCUC on DUAM case a: first card programming register (high byte) and trap of loopback test done by FW (low byte) case b: SW semaphore for PCUC answer to MPCC (on DUAM) case a: state of transmission enabling (towards UBEX on PCM lines) (high byte) and second card programming register (low byte) case b: first byte of PCUC answer to MPCC (on DUAM) case a: not used case b: second byte of PCUC answer to MPCC (on DUAM) not used

##StartSpecProbl##
Specific Problems = 328 PERIPHERAL CARD INTER PROCESSOR COMMUNICATION PROBLEM WITH TDPC

Event Type = EQUIPMENT FAILURE EVENT Severity = MINOR Proposed Repair Actions = 7 SEE THE AUTOMATIC DIAGNOSTIC TEST RESULT

Originator = 4514 MDHXXLUSA A not severe PPXU DUAM problem was detected by Inter Processor Communication task on TDPC.
aaaa = bbbb = number of source line where HwFault routine is called high byte: identifier of source item where problem was detected: 14 = DHXXLUCH; 15 = DHXXLUDE; 16 = DHXXLUEH; 17 = DHXXLUSA; 18 = DHXXLUSM; 19 = DHXXLUTH; 7 = DHXXDDDI; 22 = DHXXDDLU; 20 = DHXXLUUT; 21 = DHXXLUIN; low byte: error code: LU_CORRUPTED_DUAM 0x70 LU_MSG_NOT_AVAILABLE 0x71 LU_FULL_DUAM 0x72 LU_EMPTY_PARTITION 0x73 LU_SUCCESSFUL_WRITE 0x74 LU_EXTRACTED_CARD 0x75 number of source line (instruction calling driver where fault is detected) high byte: identifier of source item calling involved driver; low byte: error code number of source line (different from value in point aaaa only if HwFault routine is called for an error different from another problem already set) high byte: identifier of source item calling involved driver; low byte: error code (values different from values in point bbbb only if xxcuHwFault routine is called for an error different from another problem already set) bit mask of alarms not causing interrupts (high byte) and bit mask of masked UBEX alarms (low byte) power alarm (high byte) and bit mask of alarms causing interrupts (low byte) trapped PCM channel data (high byte) and trapped PCM channel address (low byte) trapped position of failed bit (if any) channel speed (high byte) and card operational parameters (low byte) first card programming register (high byte) and trap of loopback test done by FW (low byte) state of transmission enabling (towards UBEX on PCM lines) (high byte) and second card programming register (low byte) not used not used

cccc = dddd = eeee = ffff =

gggg = hhhh iiii jjjj kkkk llll = = = = =

mmmm = nnnn = oooo =

84

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Originator = 4503 MDHXXDCSA A not severe PPLD DUAM problem was detected by Inter Processor Communication task on TDPC.
aaaa = bbbb = number of source line high byte: identifier of source item where problem was detected: 1 = DHXXDCCH; 2 = DHXXDCDE; 3 = DHXXDCEH; 4 = DHXXDCSA; 5 = DHXXDCSM; 6 = DHXXDCTH; 7 = DHXXDDDI; 8 = DHXXDDHD; 9 = DHXXGSUT; 10 = DHXXININ; 11 = DGHDXXDP; 12 = DHXXDDPU; low byte: error code: 0x70 = Corrupted DUAM 0x71 = Message Not Available 0x72 = Full DUAM 0x73 = Empty Partition number of source line (instruction calling driver where fault is detected) high byte: identifier of source item calling involved driver; low byte: error code number of source line (different from value in point aaaa only if xxcuHwFault routine is called for an error different from another problem already set) high byte: identifier of source item calling involved driver; low byte: error code (values different from values in point bbbb only if xxcuHwFault routine is called for an error different from another problem already set) bit mask of alarms not causing interrupts (high byte) and bit mask of masked UBEX alarms (low byte) power alarm (high byte) and bit mask of alarms causing interrupts (low byte) trapped PCM channel data (high byte) and trapped PCM channel address (low byte) trapped position of failed bit (if any) channel speed (high byte) and card operational parameters (low byte) first card programming register (high byte) and trap of loopback test done by FW (low byte) state of transmission enabling (towards UBEX on PCM lines) (high byte) and second card programming register (low byte) not used not used

cccc = dddd = eeee = ffff =

gggg = hhhh iiii jjjj kkkk llll = = = = =

mmmm = nnnn = oooo =

##StartSpecProbl##
Specific Problems = 329 PERIPHERAL CARD FATAL HARDWARE ERROR DETECTED BY TDPC

Event Type = EQUIPMENT FAILURE EVENT Severity = MINOR Proposed Repair Actions = 1 NO ACTION

Originator = 4514 MDHXXLUSA A severe PPXU DUAM problem was detected by Inter Processor Communication task on TDPC.
A30808-X3247-K240-3-7619 85

Outputs OML:BSC
aaaa = bbbb =

Base Station Controller

number of source line where HwFault routine is called high byte: identifier of source item where problem was detected: 14 = DHXXLUCH; 15 = DHXXLUDE; 16 = DHXXLUEH; 17 = DHXXLUSA; 18 = DHXXLUSM; 19 = DHXXLUTH; 7 = DHXXDDDI; 22 = DHXXDDLU; 20 = DHXXLUUT; 21 = DHXXLUIN; low byte: error code: LU_ERR_NMI 0x50 LU_ERR_LOOP 0x51 LU_INACCESSIBLE_DUAM 0x52 LU_ALARMED_CARD 0x54 number of source line (instruction calling driver where fault is detected) high byte: identifier of source item calling involved driver; low byte: error code number of source line (different from value in point aaaa only if HwFault routine is called for an error different from another problem already set) high byte: identifier of source item calling involved driver; low byte: error code (values different from values in point bbbb only if xxcuHwFault routine is called for an error different from another problem already set) bit mask of alarms not causing interrupts (high byte) and bit mask of masked UBEX alarms (low byte) power alarm (high byte) and bit mask of alarms causing interrupts (low byte) trapped PCM channel data (high byte) and trapped PCM channel address (low byte) trapped position of failed bit (if any) channel speed (high byte) and card operational parameters (low byte) first card programming register (high byte) and trap of loopback test done by FW (low byte) state of transmission enabling (towards UBEX on PCM lines) (high byte) and second card programming register (low byte) not used not used

cccc = dddd = eeee = ffff =

gggg = hhhh iiii jjjj kkkk llll = = = = =

mmmm = nnnn = oooo =

Originator = 4503 MDHXXDCSA A severe PPLD DUAM problem was detected by Inter Processor Communication task on TDPC.
aaaa = bbbb = number of source line high byte: identifier of source item where problem was detected: 1 = DHXXDCCH; 2 = DHXXDCDE; 3 = DHXXDCEH; 4 = DHXXDCSA; 5 = DHXXDCSM; 6 = DHXXDCTH; 7 = DHXXDDDI; 8 = DHXXDDHD; 9 = DHXXGSUT; 10 = DHXXININ; 11 = DGHDXXDP; 12 = DHXXDDPU; low byte: error code: 0x50 = NMI (Non Maskable Interrupt) 0x51 = Failure of Loopback test (write/read access) 0x52 = Inaccessible DUAM 0x53 = Extracted Card 0x54 = Alarmed Card number of source line (instruction calling driver where fault is detected) high byte: identifier of source item calling involved driver; low byte: error code number of source line (different from value in point aaaa only if xxcuHwFault routine is called for an error different from another problem already set) high byte: identifier of source item calling involved driver; low byte: error code (values different from values in point bbbb only if xxcuHwFault routine is called for an error different from another problem already set) bit mask of alarms not causing interrupts (high byte) and bit mask of masked UBEX alarms

cccc = dddd = eeee = ffff =

gggg =

86

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = = (low byte) power alarm (high byte) and bit mask of alarms causing interrupts (low byte) trapped PCM channel data (high byte) and trapped PCM channel address (low byte) trapped position of failed bit (if any) channel speed (high byte) and card operational parameters (low byte) first card programming register (high byte) and trap of loopback test done by FW (low byte) state of transmission enabling (towards UBEX on PCM lines) (high byte) and second card programming register (low byte) not used not used

hhhh iiii jjjj kkkk llll

mmmm = nnnn = oooo =

##StartSpecProbl##
Specific Problems = 330 PERIPHERAL CARD DIAGNOSTIC FAILED

Event Type = EQUIPMENT FAILURE EVENT Severity = MINOR Proposed Repair Actions = 1 NO ACTION

Originator = 4512 MDHXXLUDE this error occours when a PPXU Diagnostic fail
aaaa = bbbb = cccc = dddd = eeee = ffff = source code line high byte: identifier of source item where problem was detected: 15 = DHXXLUDE; source code line (intrunction calling driver where fault is decteted) high byte: identifier of source item calling involved driver; low byte: error code number of source line (different from value in point aaaa only if HwFault routine is called for an error different from another problem already set) high byte: identifier of source item calling involved driver; low byte: error code (values different from values in point bbbb only if xxcuHwFault routine is called for an error different from another problem already set) SupervisionAlarm and Alarm Register Mask Alarm Register(hight byte) and PPXX conf Register (low) SupervisionAlarm(hight byte) and Alarm Register(low) Pentium Reset Register Power Supply Register first Byte of command memory area first Byte of responce memory area not used not used

gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

= = = = = = = = =

A30808-X3247-K240-3-7619

87

Outputs OML:BSC

Base Station Controller

Originator = 4501 MDHXXDCDE A PPLD Diagnostic Test failed.


aaaa = bbbb = number of source line high byte: identifier of source item where problem was detected: 1 = DHXXDCCH; 2 = DHXXDCDE; 3 = DHXXDCEH; 4 = DHXXDCSA; 5 = DHXXDCSM; 6 = DHXXDCTH; 7 = DHXXDDDI; 8 = DHXXDDHD; 9 = DHXXGSUT; 10 = DHXXININ; 11 = DGHDXXDP; 12 = DHXXDDPU; low byte: error code: 0xa2 = diagnostic test failure number of source line (instruction calling driver where fault is detected) high byte: identifier of source item calling involved driver; low byte: error code number of source line (different from value in point aaaa only if xxcuHwFault routine is called for an error different from another problem already set) high byte: identifier of source item calling involved driver; low byte: error code (values different from values in point bbbb only if xxcuHwFault routine is called for an error different from another problem already set) bit mask of alarms not causing interrupts (high byte) and bit mask of masked UBEX alarms (low byte) power alarm (high byte) and bit mask of alarms causing interrupts (low byte) trapped PCM channel data (high byte) and trapped PCM channel address (low byte) trapped position of failed bit (if any) channel speed (high byte) and card operational parameters (low byte) first card programming register (high byte) and trap of loopback test done by FW (low byte) state of transmission enabling (towards UBEX on PCM lines) (high byte) and second card programming register (low byte) not used not used

cccc = dddd = eeee = ffff =

gggg = hhhh iiii jjjj kkkk llll = = = = =

mmmm = nnnn = oooo =

##StartSpecProbl##
Specific Problems = 334 NTW RECOVERY REQUIRED

Event Type = EQUIPMENT FAILURE EVENT Severity = MAJOR Proposed Repair Actions = 7 SEE THE AUTOMATIC DIAGNOSTIC TEST RESULT

Originator = 4203 MDHNWDCUF, 4205 MDHNWDCAL, 4206 MDHNWDCDE A permanent fault has been detected in a not specificied device of network (ubex, pllh, sn64, sn16 or SNAP). More details can be found in the other information (see below). This error occurs when the exact information about the HW fault has been lost due to a SW
88 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

exception, possibly caused by NMI. If the fault is not due to a loop access, an invalid card type, a failed power or an arisen NMI an automatic diagnostics is required to try to recover the device.
aaaa = bbbb = (Developer oriented) Source code line where the HW fault has been detected by the device driver Internal SW code error. The possible values are: 0=>Undefined HW error 1=>Loop test failed 2=>Bus parity error 3=>HW alarm active 5=>Alarm forcing failure 6=>CRC error (only PLLH) 7=>Wrong state of communication protocol (only PLLH) 8=>Time out during HW operation 0x11=>Unexpected state of HW 0x1A=>Invalid card type 0x1D=>Overflow of UBEX interrupts 0x1E=>NMI arisen while accessing HW affected device. The possible values are: 0: unknown1: 1 UBEX 2: PLLH 3: SN64 4: SN16 5: SNAP (Developer oriented) Originator which identifies the high level source file which has detected the failure (Developer oriented) Code line of the high level source file. Dump of the ubex alarm register. The following codes can be logically OR-ed: 0x1 (bit 0): Address parity error 0x2 (bit1): Data parity error 0x4 (bit 2) Chip select error Versions of the 2 PLLH (high byte): PLLH0 bit 8 .. 11; PLLH1 bit 12 .. 15. Value of the pllh alarm register (high byte). The following codes can be logically OR-ed: 0x1 (bit 0): If this bit is set, the PLLH is distributing its own clock signal, otherwise it is distributing the clock of the other PLLH 0x2 (bit 1): the input external synchronism is missing 0x4 (bit 2): the output clock is missing 0x8 (bit 3): the input external source to be measured to is missing 0x10 (bit 4): the PLLH is not synchronized with the other PLLH 0x20 (bit 5): address parity alarm on UBEX bus 0x40 (bit 6): data parity alarm on UBEX bus 0x80 (bit 7): watch dog alarm on the local processor Internal FW code of the PLLH (low byte) 0x1=>VCXO voltage out of range 0x2=>PLL unlocked 0x3=>Excessive jitter on synchronization source 0x4=>absence of the synchronization source 0x5=>last command from MPCC has not been understood 0x6=>VCXO voltage in the pre-alarm range 0x7=>interruption of the synchronization source 0x8=>eprom checksum failure 0x9=>fault on the DAC or on the ADC 0xA=>fault in the phase comparator 0xD=>CIOA fault (only PLLH V2) Dump of the alarm registers of the input block of SN (low byte). The following codes can be logically OR-ed: 0x1 (bit 0): SN16 or SNAP: UBEX address parity error; SN64: fixed to 0 0x2 (bit 1): SN16 or SNAP: UBEX data parity error; SN64: UBEX data parity error 0x4 (bit 2): SNAP: PCM parity alarm from LICD; SN16: PCM parity error from PPXX; SN64: UBEX address parity error 0x8 (bit 3): SNAP: PCM parity alarm from PPXX (valid only if input lines are configured at 2Mb/s); SN16: PCM parity error from LICD; SN64: fixed to 0 0x10 (bit 4): SNAP: Parity address/data alarm on the CRAM; SN16: Wrong parity inside the control RAM; SN64: timing alarm 0x20 (bit 5): SNAP: Timing/Re-Route alarm; SN16: Generic alarm on input gate array;

cccc =

dddd = eeee = ffff =

gggg =

hhhh =

A30808-X3247-K240-3-7619

89

Outputs OML:BSC

Base Station Controller

SN64: fixed to 0 0x40 (bit 6): SNAP: No clock alarm; SN16: Lack of clock to input gate array; SN64: PCM parity error from LICD or PPXX 0x80 (bit 7): SNAP: No sync alarm; SN16: Lack of synchronism to the input gate array; SN64: not meaningful Dump of the alarm registers of the control block of SN (high byte). The following codes can be logically OR-ed: 0x1 (bit 0): SNAP or SN16: UBEX address parity error; SN64: fixed to 0 0x2 (bit 1): SNAP or SN16: UBEX data parity error; SN64: UBEX data parity error 0x4 (bit 2): SNAP or SN16: PLL alarm; SN64: UBEX address parity error 0x8 (bit 3): SNAP or SN16: FIFO error; SN64: generic RAM error 0x10 (bit 4): SNAP or SN16: Wrong parity inside the control RAM; SN64: timing alarm 0x20 (bit 5): SNAP: Internal timing alarm; SN16: Generic alarm on control gate array; SN64: fixed to 0 0x40 (bit 6): SNAP or SN16: Lack of clock to control gate array; SN64: not meaningful 0x80 (bit 7): SNAP or SN16: Lack of synchronism to the control gate array; SN64: not meaningful Low byte (meaningful only for SN64): dump of the global sense point. The lowest 4 bits are a redounded information of the other alarm registers of the SN64. The bit 7 (0x80) identifies the HW edition: if it is set, the edition number is greater than 2. High byte: dump of the alarm register of the output block of SN. The following codes can be logically OR-ed: 0x1 (bit 0): SNAP or SN16: UBEX address parity error; SN64: fixed to 0 0x2 (bit 1): SNAP or SN16: UBEX data parity error; SN64: UBEX data parity error 0x4 (bit 2): SNAP or SN16: parity error on parallel bus; SN64: UBEX address parity error 0x8 (bit 3): SNAP or SN16: PCM parity error from LICD; SN64: fixed to 0 0x10 (bit 4): SNAP or SN16: Wrong parity inside the control RAM; SN64: timing alarm 0x20 (bit 5): SNAP: Internal timing re-route alarm; SN16: Generic alarm on output gate array; SN64: comparison alarm 0x40 (bit 6): SNAP or SN16: Lack of clock to input gate array; SN64: PCM parity error on some output PCM line 0x80 (bit 7): SNAP or SN16: Lack of synchronism to the output gate array; SN64: not meaningful For SN64 or SN16 Bits 0-7: mask of incoming PCM 8 Mb/s lines with PCM parity alarm (lines no. 16-23); bits 8-15: not used. The 8 Mb/s lines are connected in this way: lines 0-1=>LICDS-0 lines 2-3=>LICD-0 lines 4-5=>LICD-1 lines 6-7=>LICD-2 lines 8-9=>LICD-3 lines 10-11=>LICD-4 lines 12-13=>LICD-5 lines 14-15=>LICD-6 lines 16-17=>LICD-7 lines 18-19=>LICD-8 lines 20-21=>LICDS-1 lines 22-23=>All PPCC/PPLD/PPCU For SNAP card: mask of the alarmated incoming PCM 8 Mb/s lines 0..15. The lines are connected in this way; lines 0..3 => LICDS-0 lines 4..7 => LICD-0 lines 8..11 => LICD-1 lines 12..15 => LICD-2 For SN16 or SN64: mask of incoming PCM 8 Mb/s lines with PCM parity alarm (lines no. 0-15); see previous word For SNAP card: mask of the alarmated incoming PCM 8 Mb/s lines 16..31. The lines are connected in this way; lines 16..19 => LICD-3 lines 20..23 => LICD-4 lines 24..27 => LICD-5 lines 28..31 => LICD-6

iiii =

jjjj =

kkkk =

90

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
For SN16 or SN64: Bits 0-3: mask of PCM 2 Mb/s lines coming from PPXX with PCM parity alarm; bits 4-15: not used. The 2 Mb/s lines from PPXX are connected in this way: line 0: PPCC-0,1; PPLD 0,1,2 line 1: PPLD 3,4,5,6 line 2: PPLD 7,8,9,10 or PPCU 2,3 line 3: PPLD 11,12,13,14 or PPCU 0,1 For SNAP card: mask of the alarmated incoming PCM 8 Mb/s lines 32..43. The lines are connected in this way; lines 32..35 => LICD-7 lines 36..39 => LICD-8 lines 40..43 => LICDS-1 lines 44..47 => NOT USED For SN16 or SN64: Bits 0-7: mask of outgoing PCM 8 Mb/s lines with comparison alarm (lines 16-23); bits 815: not used. The correspondence between lines and LICD is the same as the word jjjj For SNAP card: mask of the alarmated incoming PCM 8 Mb/s lines 48..55 coming from PPXX. The lines are connected in this way; lines 48..49 => PPXL 0..1 lines 50 ..55 => PPXU 0..5 lines 56..59 => NOT USED For SN16 or SN64: mask of outgoing PCM 8 Mb/s lines with comparison alarm (lines 0-15). See previous word. For SNAP card: comparison alarm on incoming PCM lines 0..15 Bit 0: Timing alarm flag of SN; bit 1: ubex bus parity alarm flag of SN (data and/or address); bit 2: cyclic test alarm (SN16 or SNAP) or control ram failure (SN64); bit 3: internal generic alarm; bit 4: alarm on ctrl G. A.; bit 5: alarm on input G. A.; bit 6: alarm on output G. A.; bit 7: fifo alarm (only SN16 and SNAP); bits 8-15: not used.

llll =

mmmm =

nnnn =

oooo =

##StartSpecProbl##
Specific Problems = 335 UBEX RECOVERY REQUIRED

Event Type = EQUIPMENT FAILURE EVENT Severity = MAJOR Proposed Repair Actions = 7 SEE THE AUTOMATIC DIAGNOSTIC TEST RESULT

Originator = 4200 MDHNWABAF, 4201 MDHNWDCHN, 4202 MDHNWDCSC, 4203 MDHNWDCUF, 4204 MDHNWININ, 4205 MDHNWDCAL, 4220 MDHUBDDCR A permanent fault has been detected on the UBEX of the affected network copy. More details can be found in the other information (see below). If the fault is not due to a loop access, an invalid card type, a failed power or an arisen NMI an automatic diagnostics is required to try to recover the device.
aaaa = bbbb = (Developer oriented) source code line where the HW fault has been detected by the device driver Internal SW code error. The possible values are: 0=>Undefined HW error1=>Loop test failed 2=>Bus parity error 3=>HW alarm active 5=>Alarm forcing failure 6=>CRC error (only PLLH) 7=>Wrong state of communication protocol (only PLLH) 8=>Time out during HW operation 0x11=>Unexpected state of HW 0x1A=>Invalid card type 0x1D=>Overflow of UBEX interrupts

A30808-X3247-K240-3-7619

91

Outputs OML:BSC
cccc =

Base Station Controller

dddd = eeee = ffff =

gggg =

0x1E=>NMI arisen while accessing HW affected device (it must be consistent with the error identity and the originator). The possible values are: 0: unknown 1: UBEX (Developer oriented) originator which identifies the high level source file which has detected the failure (Developer oriented) code line of the high level source file. Dump of the ubex alarm register. The following codes can be logically OR-ed: 0x1 (bit 0): Address parity error 0x2 (bit1): Data parity error 0x4 (bit 2) Chip select error Versions of the 2 PLLH (high byte): PLLH0 bit 8 .. 11; PLLH1 bit 12 .. 15. Value of the pllh alarm register (high byte). The following codes can be logically OR-ed: 0x1 (bit 0): If this bit is set, the PLLH is distributing its own clock signal, otherwise it is distributing the clock of the other PLLH 0x2 (bit 1): the input external synchronism is missing 0x4 (bit 2): the output clock is missing 0x8 (bit 3): the input external source to be measured to is missing 0x10 (bit 4): the PLLH is not synchronized with the other PLLH 0x20 (bit 5): address parity alarm on UBEX bus 0x40 (bit 6): data parity alarm on UBEX bus 0x80 (bit 7): watch dog alarm on the local processor Internal FW code of the PLLH (low byte) 0x1=>VCXO voltage out of range 0x2=>PLL unlocked 0x3=>Excessive jitter on synchronization source 0x4=>absence of the synchronization source 0x5=>last command from MPCC has not been understood 0x6=>VCXO voltage in the pre-alarm range 0x7=>interruption of the synchronization source 0x8=>eprom checksum failure 0x9=>fault on the DAC or on the ADC 0xA=>fault in the phase comparator 0xD=>CIOA fault (only PLLH V2) Dump of the alarm registers of the input block of SN (low byte). The following codes can be logically OR-ed: 0x1 (bit 0): SN16 or SNAP: UBEX address parity error; SN64: fixed to 0 0x2 (bit 1): SN16 or SNAP: UBEX data parity error; SN64: UBEX data parity error 0x4 (bit 2): SNAP: PCM parity alarm from LICD; SN16: PCM parity error from PPXX; SN64: UBEX address parity error 0x8 (bit 3): SNAP: PCM parity alarm from PPXX (valid only if input lines are configured at 2Mb/s); SN16: PCM parity error from LICD; SN64: fixed to 0 0x10 (bit 4): SNAP: Parity address/data alarm on the CRAM; SN16: Wrong parity inside the control RAM; SN64: timing alarm 0x20 (bit 5): SNAP: Timing/Re-Route alarm; SN16: Generic alarm on input gate array; SN64: fixed to 0 0x40 (bit 6): SNAP: No clock alarm; SN16: Lack of clock to input gate array; SN64: PCM parity error from LICD or PPXX 0x80 (bit 7): SNAP: No sync alarm; SN16: Lack of synchronism to the input gate array; SN64: not meaningful Dump of the alarm registers of the control block of SN (high byte). The following codes can be logically OR-ed: 0x1 (bit 0): SNAP or SN16: UBEX address parity error; SN64: fixed to 0 0x2 (bit 1): SNAP or SN16: UBEX data parity error; SN64: UBEX data parity error 0x4 (bit 2): SNAP or SN16: PLL alarm; SN64: UBEX address parity error 0x8 (bit 3): SNAP or SN16: FIFO error; SN64: generic RAM error 0x10 (bit 4): SNAP or SN16: Wrong parity inside the control RAM; SN64: timing alarm 0x20 (bit 5): SNAP: Internal timing alarm; SN16: Generic alarm on control gate array; SN64: fixed to 0 0x40 (bit 6): SNAP or SN16: Lack of clock to control gate array; SN64: not meaningful 0x80 (bit 7): SNAP or SN16: Lack of synchronism to the control gate array; SN64: not meaningful Low byte (meaningful only for SN64): dump of the global sense point. The lowest 4 bits are a redounded information of the other alarm registers of the SN64. The bit 7 (0x80) identifies the HW edition: if it is set, the edition number is greater than 2.

hhhh =

iiii =

92

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
High byte: dump of the alarm register of the output block of SN. The following codes can be logically OR-ed: 0x1 (bit 0): SNAP or SN16: UBEX address parity error; SN64: fixed to 0 0x2 (bit 1): SNAP or SN16: UBEX data parity error; SN64: UBEX data parity error 0x4 (bit 2): SNAP or SN16: parity error on parallel bus; SN64: UBEX address parity error 0x8 (bit 3): SNAP or SN16: PCM parity error from LICD; SN64: fixed to 0 0x10 (bit 4): SNAP or SN16: Wrong parity inside the control RAM; SN64: timing alarm 0x20 (bit 5): SNAP: Internal timing re-route alarm; SN16: Generic alarm on output gate array; SN64: comparison alarm 0x40 (bit 6): SNAP or SN16: Lack of clock to input gate array; SN64: PCM parity error on some output PCM line 0x80 (bit 7): SNAP or SN16: Lack of synchronism to the output gate array; SN64: not meaningful For SN64 or SN16 Bits 0-7: mask of incoming PCM 8 Mb/s lines with PCM parity alarm (lines no. 16-23); bits 8-15: not used. The 8 Mb/s lines are connected in this way: lines 0-1=>LICDS-0 lines 2-3=>LICD-0 lines 4-5=>LICD-1 lines 6-7=>LICD-2 lines 8-9=>LICD-3 lines 10-11=>LICD-4 lines 12-13=>LICD-5 lines 14-15=>LICD-6 lines 16-17=>LICD-7 lines 18-19=>LICD-8 lines 20-21=>LICDS-1 lines 22-23=>All PPCC/PPLD/PPCU For SNAP card: mask of the alarmated incoming PCM 8 Mb/s lines 0..15. The lines are connected in this way; lines 0..3 => LICDS-0 lines 4..7 => LICD-0 lines 8..11 => LICD-1 lines 12..15 => LICD-2 For SN16 or SN64: mask of incoming PCM 8 Mb/s lines with PCM parity alarm (lines no. 0-15); see previous word For SNAP card: mask of the alarmated incoming PCM 8 Mb/s lines 16..31. The lines are connected in this way; lines 16..19 => LICD-3 lines 20..23 => LICD-4 lines 24..27 => LICD-5 lines 28..31 => LICD-6 For SN16 or SN64: Bits 0-3: mask of PCM 2 Mb/s lines coming from PPXX with PCM parity alarm; bits 4-15: not used. The 2 Mb/s lines from PPXX are connected in this way: line 0: PPCC-0,1; PPLD 0,1,2 line 1: PPLD 3,4,5,6 line 2: PPLD 7,8,9,10 or PPCU 2,3 line 3: PPLD 11,12,13,14 or PPCU 0,1 For SNAP card: mask of the alarmated incoming PCM 8 Mb/s lines 32..43. The lines are connected in this way; lines 32..35 => LICD-7 lines 36..39 => LICD-8 lines 40..43 => LICDS-1 lines 44..47 => NOT USED For SN16 or SN64: Bits 0-7: mask of outgoing PCM 8 Mb/s lines with comparison alarm (lines 16-23); bits 815: not used. The correspondence between lines and LICD is the same as the word jjjj For SNAP card: mask of the alarmated incoming PCM 8 Mb/s lines 48..55 coming from PPXX. The lines are connected in this way; lines 48..49 => PPXL 0..1

jjjj =

kkkk =

llll =

mmmm =

A30808-X3247-K240-3-7619

93

Outputs OML:BSC

Base Station Controller

nnnn =

oooo =

lines 50 ..55 => PPXU 0..5 lines 56..59 => NOT USED For SN16 or SN64: mask of outgoing PCM 8 Mb/s lines with comparison alarm (lines 0-15). See previous word. For SNAP card: comparison alarm on incoming PCM lines 0..15 Bit 0: Timing alarm flag of SN; bit 1: ubex bus parity alarm flag of SN (data and/or address); bit 2: cyclic test alarm (SN16 or SNAP) or control ram failure (SN64); bit 3: internal generic alarm; bit 4: alarm on ctrl G. A.; bit 5: alarm on input G. A.; bit 6: alarm on output G. A.; bit 7: fifo alarm (only SN16 and SNAP); bits 8-15: not used.

##StartSpecProbl##
Specific Problems = 336 PLLH RECOVERY REQUIRED

Event Type = EQUIPMENT FAILURE EVENT Severity = MAJOR Proposed Repair Actions = 7 SEE THE AUTOMATIC DIAGNOSTIC TEST RESULT

Originator = 4200 MDHNWABAF, 4201 MDHNWDCHN, 4202 MDHNWDCSC, 4203 MDHNWDCUF, 4204 MDHNWININ, 4205 MDHNWDCAL, 4230 MDHPLDDCR A permanent fault has been detected on the PLLH of the related network copy. More details can be found in the other information (see below). If the fault is not due to a loop access, an invalid card type, a failed power or an arisen NMI an automatic diagnostics is required to try to recover the device.
aaaa = bbbb = (Developer oriented) Source code line where the HW fault has been detected by the device driver Internal SW code error. The possible values are: 0=>Undefined HW error1=>Loop test failed 2=>Bus parity error 3=>HW alarm active 5=>Alarm forcing failure 6=>CRC error (only PLLH) 7=>Wrong state of communication protocol (only PLLH) 8=>Time out during HW operation 0x11=>Unexpected state of HW 0x1A=>Invalid card type 0x1D=>Overflow of UBEX interrupts 0x1E=>NMI arisen while accessing HW affected device (it must be consistent with the error identity and the originator). The possible values are: 0: unknown 2: PLLH (Developer oriented) Originator which identifies the high level source file which has detected the failure (Developer oriented) Code line of the high level source file. Dump of the ubex alarm register. The following codes can be logically OR-ed: 0x1 (bit 0): Address parity error 0x2 (bit1): Data parity error 0x4 (bit 2) Chip select error Versions of the 2 PLLH (high byte): PLLH0 bit 8 .. 11; PLLH1 bit 12 .. 15. Value of the pllh alarm register (high byte). The following codes can be logically OR-ed: 0x1 (bit 0): If this bit is set, the PLLH is distributing its own clock signal, otherwise it is distributing the clock of the other PLLH 0x2 (bit 1): the input external synchronism is missing 0x4 (bit 2): the output clock is missing 0x8 (bit 3): the input external source to be measured to is missing 0x10 (bit 4): the PLLH is not synchronized with the other PLLH

cccc =

dddd = eeee = ffff =

gggg =

94

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
0x20 (bit 5): address parity alarm on UBEX bus 0x40 (bit 6): data parity alarm on UBEX bus 0x80 (bit 7): watch dog alarm on the local processor Internal FW code of the PLLH (low byte )0x1=>VCXO voltage out of range 0x2=>PLL unlocked0x3=>Excessive jitter on synchronization source 0x4=>absence of the synchronization source 0x5=>last command from MPCC has not been understood 0x6=>VCXO voltage in the pre-alarm range 0x7=>interruption of the synchronization source 0x8=>eprom checksum failure 0x9=>fault on the DAC or on the ADC 0xA=>fault in the phase comparator 0xD=>CIOA fault (only PLLH V2) Dump of the alarm registers of the input block of SN (low byte). The following codes can be logically OR-ed: 0x1 (bit 0): SN16 or SNAP: UBEX address parity error; SN64: fixed to 0 0x2 (bit 1): SN16 or SNAP: UBEX data parity error; SN64: UBEX data parity error 0x4 (bit 2): SNAP: PCM parity alarm from LICD; SN16: PCM parity error from PPXX; SN64: UBEX address parity error 0x8 (bit 3): SNAP: PCM parity alarm from PPXX (valid only if input lines are configured at 2Mb/s); SN16: PCM parity error from LICD; SN64: fixed to 0 0x10 (bit 4): SNAP: Parity address/data alarm on the CRAM; SN16: Wrong parity inside the control RAM; SN64: timing alarm 0x20 (bit 5): SNAP: Timing/Re-Route alarm; SN16: Generic alarm on input gate array; SN64: fixed to 0 0x40 (bit 6): SNAP: No clock alarm; SN16: Lack of clock to input gate array; SN64: PCM parity error from LICD or PPXX 0x80 (bit 7): SNAP: No sync alarm; SN16: Lack of synchronism to the input gate array; SN64: not meaningful Dump of the alarm registers of the control block of SN (high byte). The following codes can be logically OR-ed: 0x1 (bit 0): SNAP or SN16: UBEX address parity error; SN64: fixed to 0 0x2 (bit 1): SNAP or SN16: UBEX data parity error; SN64: UBEX data parity error 0x4 (bit 2): SNAP or SN16: PLL alarm; SN64: UBEX address parity error 0x8 (bit 3): SNAP or SN16: FIFO error; SN64: generic RAM error 0x10 (bit 4): SNAP or SN16: Wrong parity inside the control RAM; SN64: timing alarm 0x20 (bit 5): SNAP: Internal timing alarm; SN16: Generic alarm on control gate array; SN64: fixed to 0 0x40 (bit 6): SNAP or SN16: Lack of clock to control gate array; SN64: not meaningful 0x80 (bit 7): SNAP or SN16: Lack of synchronism to the control gate array; SN64: not meaningful Low byte (meaningful only for SN64): dump of the global sense point. The lowest 4 bits are a redounded information of the other alarm registers of the SN64. The bit 7 (0x80) identifies the HW edition: if it is set, the edition number is greater than 2. High byte: dump of the alarm register of the output block of SN. The following codes can be logically OR-ed: 0x1 (bit 0): SNAP or SN16: UBEX address parity error; SN64: fixed to 0 0x2 (bit 1): SNAP or SN16: UBEX data parity error; SN64: UBEX data parity error 0x4 (bit 2): SNAP or SN16: parity error on parallel bus; SN64: UBEX address parity error 0x8 (bit 3): SNAP or SN16: PCM parity error from LICD; SN64: fixed to 0 0x10 (bit 4): SNAP or SN16: Wrong parity inside the control RAM; SN64: timing alarm 0x20 (bit 5): SNAP: Internal timing re-route alarm; SN16: Generic alarm on output gate array; SN64: comparison alarm 0x40 (bit 6): SNAP or SN16: Lack of clock to input gate array; SN64: PCM parity error on some output PCM line 0x80 (bit 7): SNAP or SN16: Lack of synchronism to the output gate array; SN64: not meaningful For SN64 or SN16 Bits 0-7: mask of incoming PCM 8 Mb/s lines with PCM parity alarm (lines no. 16-23); bits 8-15: not used. The 8 Mb/s lines are connected in this way: lines 0-1=>LICDS-0 lines 2-3=>LICD-0 lines 4-5=>LICD-1

hhhh =

iiii =

jjjj =

A30808-X3247-K240-3-7619

95

Outputs OML:BSC

Base Station Controller

kkkk =

llll =

mmmm =

nnnn =

oooo =

lines 6-7=>LICD-2 lines 8-9=>LICD-3 lines 10-11=>LICD-4 lines 12-13=>LICD-5 lines 14-15=>LICD-6 lines 16-17=>LICD-7 lines 18-19=>LICD-8 lines 20-21=>LICDS-1 lines 22-23=>All PPCC/PPLD/PPCU For SNAP card: mask of the alarmated incoming PCM 8 Mb/s lines 0..15. The lines are connected in this way; lines 0..3 => LICDS-0 lines 4..7 => LICD-0 lines 8..11 => LICD-1 lines 12..15 => LICD-2 For SN16 or SN64: mask of incoming PCM 8 Mb/s lines with PCM parity alarm (lines no. 0-15); see previous word For SNAP card: mask of the alarmated incoming PCM 8 Mb/s lines 16..31. The lines are connected in this way; lines 16..19 => LICD-3 lines 20..23 => LICD-4 lines 24..27 => LICD-5 lines 28..31 => LICD-6 For SN16 or SN64: Bits 0-3: mask of PCM 2 Mb/s lines coming from PPXX with PCM parity alarm; bits 4-15: not used. The 2 Mb/s lines from PPXX are connected in this way: line 0: PPCC-0,1; PPLD 0,1,2 line 1: PPLD 3,4,5,6 line 2: PPLD 7,8,9,10 or PPCU 2,3 line 3: PPLD 11,12,13,14 or PPCU 0,1 For SNAP card: mask of the alarmated incoming PCM 8 Mb/s lines 32..43. The lines are connected in this way; lines 32..35 => LICD-7 lines 36..39 => LICD-8 lines 40..43 => LICDS-1 lines 44..47 => NOT USED For SN16 or SN64: Bits 0-7: mask of outgoing PCM 8 Mb/s lines with comparison alarm (lines 16-23); bits 815: not used. The correspondence between lines and LICD is the same as the word jjjj For SNAP card: mask of the alarmated incoming PCM 8 Mb/s lines 48..55 coming from PPXX. The lines are connected in this way; lines 48..49 => PPXL 0..1 lines 50 ..55 => PPXU 0..5 lines 56..59 => NOT USED For SN16 or SN64: mask of outgoing PCM 8 Mb/s lines with comparison alarm (lines 0-15). See previous word. For SNAP card: comparison alarm on incoming PCM lines 0..15 Bit 0: Timing alarm flag of SN; bit 1: ubex bus parity alarm flag of SN (data and/or address); bit 2: cyclic test alarm (SN16 or SNAP) or control ram failure (SN64); bit 3: internal generic alarm; bit 4: alarm on ctrl G. A.; bit 5: alarm on input G. A.; bit 6: alarm on output G. A.; bit 7: fifo alarm (only SN16 and SNAP); bits 8-15: not used.

##StartSpecProbl##
Specific Problems = 337 SN64 RECOVERY REQUIRED

Event Type = EQUIPMENT FAILURE EVENT


96 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Severity = MAJOR Proposed Repair Actions = 7 SEE THE AUTOMATIC DIAGNOSTIC TEST RESULT

Originator = 4200 MDHNWABAF, 4201 MDHNWDCHN, 4202 MDHNWDCSC, 4203 MDHNWDCUF, 4204 MDHNWININ, 4205 MDHNWDCAL, 4207 MDHNWDCSS, 4240 MDHSNDDCR A permanent fault has been detected on the SN64 of the related network copy. More details can be found in the other information (see below). If the fault is not due to a loop access, an invalid card type, a failed power or an arisen NMI an automatic diagnostics is required to try to recover the device.
aaaa = bbbb = (Developer oriented) Source code line where the HW fault has been detected by the device driver Internal SW code error. The possible values are: 0=>Undefined HW error 1=>Loop test failed 2=>Bus parity error 3=>HW alarm active 5=>Alarm forcing failure 6=>CRC error (only PLLH) 7=>Wrong state of communication protocol (only PLLH) 8=>Time out during HW operation 0x11=>Unexpected state of HW 0x1A=>Invalid card type 0x1D=>Overflow of UBEX interrupts 0x1E=>NMI arisen while accessing HW affected device (it must be consistent with the error identity and the originator). The possible values are: 0: unknown 3: SN64 (Developer oriented) Originator which identifies the high level source file which has detected the failure (Developer oriented) Code line of the high level source file. Dump of the ubex alarm register. The following codes can be logically OR-ed: 0x1 (bit 0): Address parity error 0x2 (bit1): Data parity error 0x4 (bit 2) Chip select error Versions of the 2 PLLH (high byte): PLLH0 bit 8 .. 11; PLLH1 bit 12 .. 15. Value of the pllh alarm register (high byte). The following codes can be logically OR-ed: 0x1 (bit 0): If this bit is set, the PLLH is distributing its own clock signal, otherwise it is distributing the clock of the other PLLH 0x2 (bit 1): the input external synchronism is missing 0x4 (bit 2): the output clock is missing 0x8 (bit 3): the input external source to be measured to is missing 0x10 (bit 4): the PLLH is not synchronized with the other PLLH 0x20 (bit 5): address parity alarm on UBEX bus 0x40 (bit 6): data parity alarm on UBEX bus 0x80 (bit 7): watch dog alarm on the local processor Internal FW code of the PLLH (low byte) 0x1=>VCXO voltage out of range 0x2=>PLL unlocked 0x3=>Excessive jitter on synchronization source 0x4=>absence of the synchronization source 0x5=>last command from MPCC has not been understood 0x6=>VCXO voltage in the pre-alarm range 0x7=>interruption of the synchronization source 0x8=>eprom checksum failure 0x9=>fault on the DAC or on the ADC 0xA=>fault in the phase comparator 0xD=>CIOA fault (only PLLH V2) Dump of the alarm registers of the input block of SN (low byte). The following codes can be logically OR-ed:

cccc =

dddd = eeee = ffff =

gggg =

hhhh =

A30808-X3247-K240-3-7619

97

Outputs OML:BSC
0x1 (bit 0): fixed to 0 0x2 (bit 1): UBEX data parity error 0x4 (bit 2): UBEX address parity error 0x8 (bit 3): fixed to 0 0x10 (bit 4): timing alarm 0x20 (bit 5): fixed to 0 0x40 (bit 6): PCM parity error from LICD or PPXX 0x80 (bit 7): not meaningful

Base Station Controller

iiii =

jjjj =

kkkk = llll =

mmmm = nnnn = oooo =

Dump of the alarm registers of the control block of SN (high byte). The following codes can be logically OR-ed: 0x1 (bit 0): fixed to 0 0x2 (bit 1): UBEX data parity error 0x4 (bit 2): UBEX address parity error 0x8 (bit 3): generic RAM error 0x10 (bit 4): timing alarm 0x20 (bit 5): fixed to 0 0x40 (bit 6): not meaningful 0x80 (bit 7): not meaningful Low byte: dump of the global sense point. The lowest 4 bits are a redounded information of the other alarm registers of the SN64. The bit 7 (0x80) identifies the HW edition: if it is set, the edition number is greater than 2. High byte: dump of the alarm register of the output block of SN. The following codes can be logically OR-ed: 0x1 (bit 0): fixed to 0 0x2 (bit 1): UBEX data parity error 0x4 (bit 2): UBEX address parity error 0x8 (bit 3): fixed to 0 0x10 (bit 4): timing alarm 0x20 (bit 5): comparison alarm 0x40 (bit 6): PCM parity error on some output PCM line 0x80 (bit 7): not meaningful Bits 0-7: mask of incoming PCM 8 Mb/s lines with PCM parity alarm (lines no. 16-23); bits 8-15: not used. The 8 Mb/s lines are connected in this way: lines 0-1=>LICDS-0 lines 2-3=>LICD-0 lines 4-5=>LICD-1 lines 6-7=>LICD-2 lines 8-9=>LICD-3 lines 10-11=>LICD-4 lines 12-13=>LICD-5l ines 14-15=>LICD-6 lines 16-17=>LICD-7 lines 18-19=>LICD-8 lines 20-21=>LICDS-1 lines 22-23=>All PPCC/PPLD/PPCU mask of incoming PCM 8 Mb/s lines with PCM parity alarm (lines no. 0-15); see previous word Bits 0-3: mask of PCM 2 Mb/s lines coming from PPXX with PCM parity alarm; bits 4-15: not used. The 2 Mb/s lines from PPXX are connected in this way: line 0: PPCC-0,1; PPLD 0,1,2 line 1: PPLD 3,4,5,6 line 2: PPLD 7,8,9,10 or PPCU 2,3 line 3: PPLD 11,12,13,14 or PPCU 0,1 Bits 0-7: mask of outgoing PCM 8 Mb/s lines with comparison alarm (lines 16-23); bits 815: not used. The correspondence between lines and LICD is the same as the word jjjj mask of outgoing PCM 8 Mb/s lines with comparison alarm (lines 0-15). See previous word. Bit 0: Timing alarm flag of SN; bit 1: ubex bus parity alarm flag of SN (data and/or address); bit 2: control ram failure; bit 3: internal generic alarm; bit 4: alarm on ctrl G. A.; bit 5: alarm on input G. A.; bit 6: alarm on output G. A.; bits 7-15: not used.

##StartSpecProbl##
98 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Specific Problems = 343 SNAP RECOVERY REQUIRED

Event Type = EQUIPMENT FAILURE EVENT Severity = MAJOR Proposed Repair Actions = 7 SEE THE AUTOMATIC DIAGNOSTIC TEST RESULT

Originator = 4200 MDHNWABAF, 4205 MDHNWDCAL, 4207 MDHNWDCSS, 4250 MDHNWDD08 A permanent fault has been detected on the SNAP of the affected network copy. More details can be found in the other information (see below). If the fault is not due to a loop access, an invalid card type, a failed power or an arisen NMI an automatic diagnostics is required to try to recover the device..
aaaa = bbbb = (Developer oriented) Source code line where the HW fault has been detected by the device driver Internal SW code error. The possible values are: 0=>Undefined HW error 1=>Loop test failed 2=>Bus parity error 3=>HW alarm active 5=>Alarm forcing failure 6=>CRC error (only PLLH) 7=>Wrong state of communication protocol (only PLLH) 8=>Time out during HW operation 0x11=>Unexpected state of HW 0x1A=>Invalid card type 0x1D=>Overflow of UBEX interrupts 0x1E=>NMI arisen while accessing HW affected device (it must be consistent with the error identity and the originator). The possible values are: 0: unknown 5: SNAP (Developer oriented) Originator which identifies the high level source file which has detected the failure (Developer oriented) Code line of the high level source file. Dump of the ubex alarm register. The following codes can be logically OR-ed: 0x1 (bit 0): Address parity error 0x2 (bit1): Data parity error 0x4 (bit 2) Chip select error Versions of the 2 PLLH (high byte): PLLH0 bit 8 .. 11; PLLH1 bit 12 .. 15. Value of the pllh alarm register (high byte). The following codes can be logically OR-ed: 0x1 (bit 0): If this bit is set, the PLLH is distributing its own clock signal, otherwise it is distributing the clock of the other PLLH 0x2 (bit 1): the input external synchronism is missing 0x4 (bit 2): the output clock is missing 0x8 (bit 3): the input external source to be measured to is missing 0x10 (bit 4): the PLLH is not synchronized with the other PLLH 0x20 (bit 5): address parity alarm on UBEX bus 0x40 (bit 6): data parity alarm on UBEX bus 0x80 (bit 7): watch dog alarm on the local processor Internal FW code of the PLLH (low byte) 0x1=>VCXO voltage out of range 0x2=>PLL unlocked 0x3=>Excessive jitter on synchronization source 0x4=>absence of the synchronization source 0x5=>last command from MPCC has not been understood 0x6=>VCXO voltage in the pre-alarm range 0x7=>interruption of the synchronization source 0x8=>eprom checksum failure 0x9=>fault on the DAC or on the ADC 0xA=>fault in the phase comparator 0xD=>CIOA fault (only PLLH V2)

cccc =

dddd = eeee = ffff =

gggg =

A30808-X3247-K240-3-7619

99

Outputs OML:BSC
hhhh =

Base Station Controller

Dump of the alarm registers of the input block of SN (low byte). The following codes can be logically OR-ed: 0x1 (bit 0): UBEX address parity error 0x2 (bit 1): UBEX data parity error 0x4 (bit 2): PCM parity alarm from LICD 0x8 (bit 3): PCM parity alarm from PPXX (valid only if input lines are configured at 2Mb/s) 0x10 (bit 4): Parity address/data alarm on the CRAM 0x20 (bit 5): Timing/Re-Route alarm 0x40 (bit 6): No clock alarm 0x80 (bit 7): No sync alarm Dump of the alarm registers of the control block of SN (high byte). The following codes can be logically OR-ed: 0x1 (bit 0): UBEX address parity error 0x2 (bit 1): UBEX data parity error 0x4 (bit 2): PLLH alarm 0x8 (bit 3): FIFO error; 0x10 (bit 4): Wrong parity inside the control RAM 0x20 (bit 5): Internal timing alarm 0x40 (bit 6): Lack of clock to control gate array 0x80 (bit 7): Lack of synchronism to the control gate array Low byte: not meaninigful. High byte: dump of the alarm register of the output block of SN. The following codes can be logically OR-ed: 0x1 (bit 0): UBEX address parity error 0x2 (bit 1): UBEX data parity error 0x4 (bit 2): parity error on parallel bus 0x8 (bit 3): PCM parity error from LICD 0x10 (bit 4): Wong parity inside the control RAM 0x20 (bit 5): Internal timing re-route alarm 0x40 (bit 6): Lack of clock to input gate array 0x80 (bit 7): Lack of synchronism to the output gate array mask of the alarmated incoming PCM 8 Mb/s lines 0..15. The lines are connected in this way; lines 0..3 => LICDS-0 lines 4..7 => LICD-0 lines 8..11 => LICD-1 lines 12..15 => LICD-2 mask of the alarmated incoming PCM 8 Mb/s lines 16..31. The lines are connected in this way; lines 16..19 => LICD-3 lines 20..23 => LICD-4 lines 24..27 => LICD-5 lines 28..31 => LICD-6 mask of the alarmated incoming PCM 8 Mb/s lines 32..43. The lines are connected in this way; lines 32..35 => LICD-7 lines 36..39 => LICD-8 lines 40..43 => LICDS-1 lines 44..47 => NOT USED mask of the alarmated incoming PCM 8 Mb/s lines 48..55 coming from PPXX. The lines are connected in this way; lines 48..49 => PPXL 0..1 lines 50 ..55 => PPXU 0..5 lines 56..59 => NOT USED comparison alarm on incoming PCM lines 0..15 Bit 0: Timing alarm flag of SN; bit 1: ubex bus parity alarm flag of SN (data and/or address); bit 2: cyclic test alarm; bit 3: internal generic alarm; bit 4: alarm on ctrl G. A.; bit 5: alarm on input G. A.; bit 6: alarm on output G. A.; bit 7: fifo alarm; bits 8-15: not used.

iiii =

jjjj =

kkkk =

llll =

mmmm =

nnnn = oooo =

##StartSpecProbl##
Specific Problems = 338 SN16 RECOVERY REQUIRED

100

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Event Type = EQUIPMENT FAILURE EVENT Severity = MAJOR Proposed Repair Actions = 7 SEE THE AUTOMATIC DIAGNOSTIC TEST RESULT

Originator = 4200 MDHNWABAF, 4205 MDHNWDCAL, 4207 MDHNWDCSS, 4250 MDH16DDCR A permanent fault has been detected on the SN16 of the affected network copy. More details can be found in the other information (see below). If the fault is not due to a loop access, an invalid card type, a failed power or an arisen NMI an automatic diagnostics is required to try to recover the device..
aaaa = bbbb = (Developer oriented) Source code line where the HW fault has been detected by the device driver Internal SW code error. The possible values are: 0=>Undefined HW error 1=>Loop test failed 2=>Bus parity error 3=>HW alarm active 5=>Alarm forcing failure 6=>CRC error (only PLLH) 7=>Wrong state of communication protocol (only PLLH) 8=>Time out during HW operation 0x11=>Unexpected state of HW 0x1A=>Invalid card type 0x1D=>Overflow of UBEX interrupts 0x1E=>NMI arisen while accessing HW affected device (it must be consistent with the error identity and the originator). The possible values are: 0: unknown 4: SN16 (Developer oriented) Originator which identifies the high level source file which has detected the failure (Developer oriented) Code line of the high level source file. Dump of the ubex alarm register. The following codes can be logically OR-ed: 0x1 (bit 0): Address parity error 0x2 (bit1): Data parity error 0x4 (bit 2) Chip select error Versions of the 2 PLLH (high byte): PLLH0 bit 8 .. 11; PLLH1 bit 12 .. 15. Value of the pllh alarm register (high byte). The following codes can be logically OR-ed: 0x1 (bit 0): If this bit is set, the PLLH is distributing its own clock signal, otherwise it is distributing the clock of the other PLLH 0x2 (bit 1): the input external synchronism is missing 0x4 (bit 2): the output clock is missing 0x8 (bit 3): the input external source to be measured to is missing 0x10 (bit 4): the PLLH is not synchronized with the other PLLH 0x20 (bit 5): address parity alarm on UBEX bus 0x40 (bit 6): data parity alarm on UBEX bus 0x80 (bit 7): watch dog alarm on the local processor Internal FW code of the PLLH (low byte) 0x1=>VCXO voltage out of range 0x2=>PLL unlocked 0x3=>Excessive jitter on synchronization source 0x4=>absence of the synchronization source 0x5=>last command from MPCC has not been understood 0x6=>VCXO voltage in the pre-alarm range 0x7=>interruption of the synchronization source 0x8=>eprom checksum failure 0x9=>fault on the DAC or on the ADC 0xA=>fault in the phase comparator0xD=>CIOA fault (only PLLH V2) Dump of the alarm registers of the input block of SN (low byte). The following codes can be logically OR-ed: 0x1 (bit 0): UBEX address parity error

cccc =

dddd = eeee = ffff =

gggg =

hhhh =

A30808-X3247-K240-3-7619

101

Outputs OML:BSC
0x2 (bit 1): UBEX data parity error 0x4 (bit 2): PCM parity error from PPXX 0x8 (bit 3): PCM parity error from LICD 0x10 (bit 4): Wrong parity inside the control RAM 0x20 (bit 5): Generic alarm on input gate array 0x40 (bit 6): Lack of clock to input gate array 0x80 (bit 7): Lack of synchronism to the input gate array

Base Station Controller

iiii =

Dump of the alarm registers of the control block of SN (high byte). The following codes can be logically OR-ed: 0x1 (bit 0): UBEX address parity error 0x2 (bit 1): UBEX data parity error 0x4 (bit 2): PLL alarm 0x8 (bit 3): FIFO error 0x10 (bit 4): Wrong parity inside the control RAM 0x20 (bit 5): Generic alarm on control gate array 0x40 (bit 6): Lack of clock to control gate array 0x80 (bit 7): Lack of synchronism to the control gate array Low byte not meaningful. High byte: dump of the alarm register of the output block of SN. The following codes can be logically OR-ed: 0x1 (bit 0): UBEX address parity error 0x2 (bit 1): UBEX data parity error 0x4 (bit 2): parity error on parallel bus 0x8 (bit 3): PCM parity error from LICD 0x10 (bit 4): Wrong parity inside the control RAM 0x20 (bit 5): Generic alarm on output gate array 0x40 (bit 6): Lack of clock to input gate array 0x80 (bit 7): Lack of synchronism to the output gate array Bits 0-7: mask of incoming PCM 8 Mb/s lines with PCM parity alarm (lines no. 16-23); bits 8-15: not used. The 8 Mb/s lines are connected in this way: lines 0-1=>LICDS-0 lines 2-3=>LICD-0 lines 4-5=>LICD-1 lines 6-7=>LICD-2 lines 8-9=>LICD-3 lines 10-11=>LICD-4 lines 12-13=>LICD-5 lines 14-15=>LICD-6 lines 16-17=>LICD-7 lines 18-19=>LICD-8 lines 20-21=>LICDS-1 lines 22-23=>All PPCC/PPLD/PPCU mask of incoming PCM 8 Mb/s lines with PCM parity alarm (lines no. 0-15); see previous word Bits 0-3: mask of PCM 2 Mb/s lines coming from PPXX with PCM parity alarm; bits 4-15: not used. The 2 Mb/s lines from PPXX are connected in this way: line 0: PPCC-0,1; PPLD 0,1,2 line 1: PPLD 3,4,5,6 line 2: PPLD 7,8,9,10 or PPCU 2,3 line 3: PPLD 11,12,13,14 or PPCU 0,1 Bits 0-7: mask of outgoing PCM 8 Mb/s lines with comparison alarm (lines 16-23); bits 815: not used. The correspondence between lines and LICD is the same as the word jjjj mask of outgoing PCM 8 Mb/s lines with comparison alarm (lines 0-15). See previous word. Bit 0: Timing alarm flag of SN16; bit 1: ubex bus parity alarm flag of SN16 (data and/or address); bit 2: cyclic test alarm; bit 3: internal generic alarm; bit 4: alarm on ctrl G. A.; bit 5: alarm on input G. A.; bit 6: alarm on output G. A.; bit 7: fifo alarm; bits 8-15: not used.

jjjj =

kkkk = llll =

mmmm = nnnn = oooo =

102

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

16 LINE INTERFACE FAILURE


FAILURE EVENT REPORT: NAME = Probable cause = Specific Problems = Event Type = Event Time = Severity = Trend Indication = Notification Identifier = Correlated Notification Identifier = Related MO = Proposed Repair Actions = Additional Text = Originator = Additional Words =
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo <R.T.D.>

<R.T.D.> <R.T.D.> Line Interface Failure <see legend> <see legend> <R.T.D.> <see legend> <R.T.D.> <R.T.D.> <displayed only during Alarm Alignment> <R.T.D.> <R.T.D.> <see legend> <R.T.D.> <see legend>

Software Version =

Legend:

##StartSpecProbl##
Specific Problems = 189 LOSS OF SIGNAL

Event Type = COMMUNICATION FAILURE EVENT Severity = CRITICAL Proposed Repair Actions = 15 CHECK CABLES, CONNECTIONS, LINE QUALITY

Originator = 4404 MDHLCSASC The LICD does not receive the signal on the PCM line.
aaaa = bbbb = cccc = Developer reserved: code line number where error is emitted Licd type (0=DTLP, 1=QTLP, 2=QTLP V2) LOW BYTE contains the logical licd number (the object which manages a group of PCM lines, defined in the database), HIGH BYTE contains the phisycal licd (hardware card effectively in service). It may be different from the logical licd if the LICDS is providing service (9=spare 0, A=spare 1). Line involved (0-3) Link involved (1=link A, 2=link B) It should be always 0x100 High byte: counter of the L1CTS alarm rising edges Low byte: last value (2 bits long) trapped on the time slot

dddd eeee ffff gggg

= = = =

A30808-X3247-K240-3-7619

103

Outputs OML:BSC
hhhh = iiii = jjjj = kkkk = llll = mmmm = nnnn =

Base Station Controller

oooo =

Number of time slot at 16 Kb/s configured as L1CTS (4..124) High byte: LOS present Low byte: AIS alarm present High byte: LFA present Low byte: EER alarm present High byte: RAI present Low byte: LCA alarm present rnua alarm present LOW BYTE contains : lnua alarm present. HIGH BYTE contains: working mode (DD = double trunk , BB = single trunk ) If LicdType = DTLP then b5 alarm present, it means that the bit no. 5 of the time slot 0 is different from the expected value (1). In some networks of telecommunications it is used to notify the loss of synchronization (timing alarm procedure). For the GSM network however it is generally unused. It is handled only by the DTLP. If LicdType = QTLP V1 or QTLP V2 then alarm causes AA= Pcm Permanent CC= Pcm Micro Interruptions. LOW BYTE contains: txal alarm present, it reveals a wrong parity on the PCM stream transmitted to the LICD by the switching matrix. This signal is transmitted through a bus that is composed, for each LICD, by 4 lines at 8 Mb/s (of which 2 are redunded, and carry the parity signal). This alarm can be induced either by clock problems (due to PLLH), or by some faulted circuit on the switching matrix, or by some fault in the PCM parity checker of the LICD. It is handled only by the QTLP V1. HIGH BYTE contains: type of pcm working mode 24(16h)->PCM24; 32(20h)->PCM32.

##StartSpecProbl##
Specific Problems = 190 LOSS OF SIGNAL ON LINK A

Event Type = COMMUNICATION FAILURE EVENT Severity = MINOR Proposed Repair Actions = 15 CHECK CABLES, CONNECTIONS, LINE QUALITY

Originator = 4404 MDHLCSASC The LICD does not receive the signal on the link A of the PCM line. This alarm causes a reduction of the redundancy state of the line, and can be issued only for PCM lines configured in duplex.
aaaa = bbbb = cccc = Developer reserved: code line number where error is emitted Licd type (0=DTLP, 1=QTLP, 2=QTLP V2) LOW BYTE contains the logical licd number (the object which manages a group of PCM lines, defined in the database), HIGH BYTE contains the phisycal licd (hardware card effectively in service). It may be different from the logical licd if the LICDS is providing service (9=spare 0, A=spare 1). Line involved (0-3) Link involved (1=link A, 2=link B) signal absent ais alarm present lfa alarm present eer alarm present rai alarm present lca alarm present rnua alarm present LOW BYTE contains : lnua alarm present. HIGH BYTE contains: working mode (DD = double trunk , BB = single trunk )

dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm

= = = = = = = = = =

104

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
If LicdType = DTLP then b5 alarm present, it means that the bit no. 5 of the time slot 0 is different from the expected value (1). In some networks of telecommunications it is used to notify the loss of synchronization (timing alarm procedure). For the GSM network however it is generally unused. It is handled only by the DTLP. If LicdType = QTLP V1 or QTLP V2 then alarm causes AA= Pcm Permanent CC = Pcm Micro Interruptions . LOW BYTE contains: txal alarm present, it reveals a wrong parity on the PCM stream transmitted to the LICD by the switching matrix. This signal is transmitted through a bus that is composed, for each LICD, by 4 lines at 8 Mb/s (of which 2 are redunded, and carry the parity signal). This alarm can be induced either by clock problems (due to PLLH), or by some faulted circuit on the switching matrix, or by some fault in the PCM parity checker of the LICD. It is handled only by the QTLP V1. HIGH BYTE contains: type of pcm working mode 24(16h)->PCM24; 32(20h)->PCM32.

nnnn =

oooo =

##StartSpecProbl##
Specific Problems = 191 LOSS OF SIGNAL ON LINK B

Event Type = COMMUNICATION FAILURE EVENT Severity = MINOR Proposed Repair Actions = 15 CHECK CABLES, CONNECTIONS, LINE QUALITY

Originator = 4404 MDHLCSASC The LICD does not receive the signal on the link B of the PCM line. This alarm causes a reduction of the redundancy state of the line, and can be issued only for PCM lines configured in duplex.
aaaa = bbbb = cccc = Developer reserved: code line number where error is emitted Licd type (0=DTLP, 1=QTLP, 2=QTLP V2) LOW BYTE contains the logical licd number (the object which manages a group of PCM lines, defined in the database), HIGH BYTE contains the phisycal licd (hardware card effectively in service). It may be different from the logical licd if the LICDS is providing service (9=spare 0, A=spare 1). Line involved (0-3) Link involved (1=link A, 2=link B) signal absent ais alarm present lfa alarm present eer alarm present rai alarm present lca alarm present rnua alarm present LOW BYTE contains : lnua alarm present. HIGH BYTE contains: working mode (DD = double trunk , BB = single trunk ) If LicdType = DTLP then b5 alarm present, it means that the bit no. 5 of the time slot 0 is different from the expected value (1). In some networks of telecommunications it is used to notify the loss of synchronization (timing alarm procedure). For the GSM network however it is generally unused. It is handled only by the DTLP. If LicdType = QTLP V1 or QTLP V2 then alarm causes AA= Pcm Permanent CC = Pcm Micro Interruptions. LOW BYTE contains: txal alarm present, it reveals a wrong parity on the PCM stream transmitted to the LICD by the switching matrix. This signal is transmitted through a bus that is composed, for each LICD, by 4 lines at 8 Mb/s (of which 2 are redunded, and carry the parity signal). This alarm can be induced either by clock problems (due to PLLH), or by some faulted circuit on the switching matrix, or by some fault in the PCM parity checker of

dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm

= = = = = = = = = =

nnnn =

oooo =

A30808-X3247-K240-3-7619

105

Outputs OML:BSC

Base Station Controller

the LICD. It is handled only by the QTLP V1. HIGH BYTE contains: type of pcm working mode 24(16h)->PCM24; 32(20h)->PCM32.

##StartSpecProbl##
Specific Problems = 192 AIS ALARM

Event Type = COMMUNICATION FAILURE EVENT Severity = MAJOR Proposed Repair Actions = 11 CHECK THE RECEIVED SIGNAL

Originator = 4404 MDHLCSASC The "AIS" alarm has occurred on the line. This means that the PCM stream is composed by bits that are all 1.
aaaa = bbbb = cccc = Developer reserved: code line number where error is emitted Licd type (0=DTLP, 1=QTLP, 2=QTLP V2) LOW BYTE contains the logical licd number (the object which manages a group of PCM lines, defined in the database), HIGH BYTE contains the phisycal licd (hardware card effectively in service). It may be different from the logical licd if the LICDS is providing service (9=spare 0, A=spare 1). Line involved (0-3) Link involved (1=link A, 2=link B) signal absent ais alarm present lfa alarm present eer alarm present rai alarm present lca alarm present rnua alarm present LOW BYTE contains : lnua alarm present. HIGH BYTE contains: working mode (DD = double trunk , BB = single trunk ) If LicdType = DTLP then b5 alarm present, it means that the bit no. 5 of the time slot 0 is different from the expected value (1). In some networks of telecommunications it is used to notify the loss of synchronization (timing alarm procedure). For the GSM network however it is generally unused. It is handled only by the DTLP. If LicdType = QTLP V1 or QTLP V2 then alarm causes AA= Pcm Permanent CC = Pcm Micro Interruptions . LOW BYTE contains: txal alarm present, it reveals a wrong parity on the PCM stream transmitted to the LICD by the switching matrix. This signal is transmitted through a bus that is composed, for each LICD, by 4 lines at 8 Mb/s (of which 2 are redunded, and carry the parity signal). This alarm can be induced either by clock problems (due to PLLH), or by some faulted circuit on the switching matrix, or by some fault in the PCM parity checker of the LICD. It is handled only by the QTLP V1. HIGH BYTE contains: type of pcm working mode 24(16h)->PCM24; 32(20h)->PCM32.

dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm

= = = = = = = = = =

nnnn =

oooo =

##StartSpecProbl##
Specific Problems = 193 AIS ALARM ON LINK A

106

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Event Type = COMMUNICATION FAILURE EVENT Severity = MINOR Proposed Repair Actions = 11 CHECK THE RECEIVED SIGNAL

Originator = 4404 MDHLCSASC The "AIS" alarm has occurred on the link A of the line. This means that the PCM stream is composed by bits that are all 1. This alarm causes a reduction of the redundancy state of the line, and can be issued only for PCM lines configured in duplex.
aaaa = bbbb = cccc = Developer reserved: code line number where error is emitted Licd type (0=DTLP, 1=QTLP, 2=QTLP V2) LOW BYTE contains the logical licd number (the object which manages a group of PCM lines, defined in the database), HIGH BYTE contains the phisycal licd (hardware card effectively in service). It may be different from the logical licd if the LICDS isproviding service (9=spare 0, A=spare 1). Line involved (0-3) Link involved (1=link A, 2=link B) signal absent ais alarm present lfa alarm present eer alarm present rai alarm present lca alarm present rnua alarm present LOW BYTE contains : lnua alarm present. HIGH BYTE contains: working mode (DD = double trunk , BB = single trunk ) If LicdType = DTLP then b5 alarm present, it means that the bit no. 5 of the time slot 0 is different from the expected value (1). In some networks of telecommunications it is used to notify the loss of synchronization (timing alarm procedure). For the GSM network however it is generally unused. It is handled only by the DTLP. If LicdType = QTLP V1 or QTLP V2 then alarm causes AA= Pcm Permanent CC = Pcm Micro Interruptions . LOW BYTE contains: txal alarm present, it reveals a wrong parity on the PCM stream transmitted to the LICD by the switching matrix. This signal is transmitted through a bus that is composed, for each LICD, by 4 lines at 8 Mb/s (of which 2 are redunded, and carry the parity signal). This alarm can be induced either by clock problems (due to PLLH), or by some faulted circuit on the switching matrix, or by some fault in the PCM parity checker of the LICD. It is handled only by the QTLP V1. HIGH BYTE contains: type of pcm working mode 24(16h)->PCM24; 32(20h)->PCM32.

dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm

= = = = = = = = = =

nnnn =

oooo =

##StartSpecProbl##
Specific Problems = 194 AIS ALARM ON LINK B

Event Type = COMMUNICATION FAILURE EVENT Severity = MINOR Proposed Repair Actions = 11 CHECK THE RECEIVED SIGNAL

Originator = 4404 MDHLCSASC

A30808-X3247-K240-3-7619

107

Outputs OML:BSC

Base Station Controller

The "AIS" alarm has occurred on the link B of the line. This means that the PCM stream is composed by bits that are all 1. This alarm causes a reduction of the redundancy state of the line, and can be issued only for PCM lines configured in duplex.
aaaa = bbbb = cccc = Developer reserved: code line number where error is emitted Licd type (0=DTLP, 1=QTLP, 2=QTLP V2) LOW BYTE contains the logical licd number (the object which manages a group of PCM lines, defined in the database), HIGH BYTE contains the phisycal licd (hardware card effectively in service). It may be different from the logical licd if the LICDS isproviding service (9=spare 0, A=spare 1). Line involved (0-3) Link involved (1=link A, 2=link B) signal absent ais alarm present lfa alarm present eer alarm present rai alarm present lca alarm present rnua alarm present LOW BYTE contains : lnua alarm present. HIGH BYTE contains: working mode (DD = double trunk , BB = single trunk ) If LicdType = DTLP then b5 alarm present, it means that the bit no. 5 of the time slot 0 is different from the expected value (1). In some networks of telecommunications it is used to notify the loss of synchronization (timing alarm procedure). For the GSM network however it is generally unused. It is handled only by the DTLP. If LicdType = QTLP V1 or QTLP V2 then alarm causes AA= Pcm Permanent CC = Pcm Micro Interruptions . LOW BYTE contains: txal alarm present, it reveals a wrong parity on the PCM stream transmitted to the LICD by the switching matrix. This signal is transmitted through a bus that is composed, for each LICD, by 4 lines at 8 Mb/s (of which 2 are redunded, and carry the parity signal). This alarm can be induced either by clock problems (due to PLLH), or by some faulted circuit on the switching matrix, or by some fault in the PCM parity checker of the LICD. It is handled only by the QTLP V1. HIGH BYTE contains: type of pcm working mode 24(16h)->PCM24; 32(20h)->PCM32.

dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm

= = = = = = = = = =

nnnn =

oooo =

##StartSpecProbl##
Specific Problems = 257 L1CTS INTERRUPTION

Event Type = COMMUNICATION FAILURE EVENT Severity = MAJOR Proposed Repair Actions = 15 CHECK CABLES, CONNECTIONS, LINE QUALITY

Originator = 4404 MDHLCSASC An interruption has been detected (downlink or uplink) in the PCM link between the BSC and a BTS that is directly connected to it. This interruption is detected by the BSC by monitoring the pattern received on the Layer 1 Control Time Slot, which can be configured in the BSC database for the PCMB objects. This mechanism of fault detection is applied only for the PCMB in simplex mode. For the PCMB on duplex mode, instead, the Layer 1 Control Time Slot, if configured, is handled only by the BTS. The PCMB is put in disabled/offline state. As a consequence, all the traffic channels that are subordinate of the PCMB cannot be used as long as the alarm is present.
aaaa = Developer reserved: code line number where error is emitted

108

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
Licd type (0=DTLP, 1=QTLP, 2=QTLP V2) LOW BYTE contains the logical licd number (the object which manages a group of PCM lines, defined in the database), HIGH BYTE contains the phisycal licd (hardware card effectively in service). It may be different from the logical licd if the LICDS is providing service (9=spare 0, A=spare 1). Line involved (0-3) Link involved (1=link A, 2=link B) signal absent ais alarm present lfa alarm present eer alarm present rai alarm present lca alarm present rnua alarm present LOW BYTE contains : lnua alarm present. HIGH BYTE contains: working mode (DD = double trunk , BB = single trunk ) If LicdType = DTLP then b5 alarm present, it means that the bit no. 5 of the time slot 0 is different from the expected value (1). In some networks of telecommunications it is used to notify the loss of synchronization (timing alarm procedure). For the GSM network however it is generally unused. It is handled only by the DTLP. If LicdType = QTLP V1 or QTLP V2 then alarm causes AA= Pcm Permanent CC = Pcm Micro Interruptions . LOW BYTE contains: txal alarm present, it reveals a wrong parity on the PCM stream transmitted to the LICD by the switching matrix. This signal is transmitted through a bus that is composed, for each LICD, by 4 lines at 8 Mb/s (of which 2 are redunded, and carry the LOW parity signal). This alarm can be induced either by clock problems (due to PLLH), or by some faulted circuit on the switching matrix, or by some fault in the PCM parity checker of the LICD. It is handled only by the QTLP V1. HIGH BYTE contains: type of pcm working mode 24(16h)->PCM24; 32(20h)->PCM32.

bbbb = cccc =

dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm

= = = = = = = = = =

nnnn =

oooo =

##StartSpecProbl##
Specific Problems = 266 MPCC HOT LINK FAILED

Event Type = QUALITY OF SERVICE FAILURE EVENT Severity = MAJOR Proposed Repair Actions = 15 CHECK CABLES, CONNECTIONS, LINE QUALITY

Originator = 4603 MDHPRDCUT This error is reported when the start of the Hot Link functionality fails and the diagnostic of the local circuitry of the active card failed.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj = = = = = = = = = = the line of the source module where the error is issued. the hot link diagnostic failure code (high word). the hot link diagnostic failure code (low word). not used. not used. not used. not used. not used. not used. not used.

A30808-X3247-K240-3-7619

109

Outputs OML:BSC
kkkk llll mmmm nnnn oooo = = = = = not used. not used. not used. not used. not used.

Base Station Controller

Originator = 4604 MDHPRDCSM This error is reported when the Hot Link is found failed after the standby card diagnostic, due to HW problems of the link cable.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = line of the source module where the error is issued. the hot link failure code (high word). the hot link failure code (low word). not used. not used. not used. not used. not used. not used. not used. not used. not used. not used. not used. not used.

##StartSpecProbl##
Specific Problems = 267 TDPC HOT LINK FAILED

Event Type = QUALITY OF SERVICE FAILURE EVENT Severity = MAJOR Proposed Repair Actions = 15 CHECK CABLES, CONNECTIONS, LINE QUALITY

Originator = 4603 MDHPRDCUT This error is reported when the start of the Hot Link functionality fails and the diagnostic of the local circuitry of the active card failed.
aaaa bbbb cccc dddd eeee ffff = = = = = = the line of the source module where the error is issued. the hot link diagnostic failure code (high word). the hot link diagnostic failure code (low word). not used. not used. not used.

110

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = = = = = = not used. not used. not used. not used. not used. not used. not used. not used. not used.

gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

Originator = 4604 MDHPRDCSM This error is reported when the Hot Link is found failed after the standby card diagnostic, due to HW problems of the link cable.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = line of the source module where the error is issued. the hot link failure code (high word). the hot link failure code (low word). not used. not used. not used. not used. not used. not used. not used. not used. not used. not used. not used. not used.

##StartSpecProbl##
Specific Problems = 282 NOTIFIED LOSS OF SIGNAL

Event Type = COMMUNICATION FAILURE EVENT Severity = MAJOR Proposed Repair Actions = 15 CHECK CABLES, CONNECTIONS, LINE QUALITY

Originator = 4400 MDHLCDCDE, 4754 TDHTRDCMS Error notified by TRAU towards the BSC on PCMA/PCMS objects. See TRAU error manual at error LOSS_OF_SIGNAL.
aaaa = bbbb = cccc = See TRAU error manual. See TRAU error manual. See TRAU error manual.

A30808-X3247-K240-3-7619

111

Outputs OML:BSC
dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual.

Base Station Controller

##StartSpecProbl##
Specific Problems = 283 NOTIFIED AIS ALARM

Event Type = COMMUNICATION FAILURE EVENT Severity = MAJOR Proposed Repair Actions = 15 CHECK CABLES, CONNECTIONS, LINE QUALITY

Originator = 4400 MDHLCDCDE, 4754 TDHTRDCMS Error notified by TRAU towards the BSC on PCMA/PCMS objects. See TRAU error manual at error AIS_ALARM.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual.

##StartSpecProbl##
Specific Problems = 289 NOTIFIED LOSS OF SIGNAL ON LINK A

Event Type = COMMUNICATION FAILURE EVENT Severity = MINOR


112 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Proposed Repair Actions = 15 CHECK CABLES, CONNECTIONS, LINE QUALITY

Originator = 4400 MDHLCDCDE, 4754 TDHTRDCMS Error notified by TRAU towards the BSC on PCMS/PCMA objects. See TRAU error manual at error LOSS_OF_SIGNAL ON_LINK_A.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual.

##StartSpecProbl##
Specific Problems = 290 NOTIFIED LOSS OF SIGNAL ON LINK B

Event Type = COMMUNICATION FAILURE EVENT Severity = MINOR Proposed Repair Actions = 15 CHECK CABLES, CONNECTIONS, LINE QUALITY

Originator = 4400 MDHLCDCDE, 4754 TDHTRDCMS Error notified by TRAU towards the BSC on PCMS/PCMA objects. See TRAU error manual at error LOSS_OF_SIGNAL_ON_LINK_B.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn = = = = = = = = = = = = = = See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual.

A30808-X3247-K240-3-7619

113

Outputs OML:BSC
oooo = See TRAU error manual.

Base Station Controller

##StartSpecProbl##
Specific Problems = 291 NOTIFIED AIS ALARM ON LINK A

Event Type = COMMUNICATION FAILURE EVENT Severity = MINOR Proposed Repair Actions = 15 CHECK CABLES, CONNECTIONS, LINE QUALITY

Originator = 4400 MDHLCDCDE, 4754 TDHTRDCMS Error notified by TRAU towards the BSC on PCMS/PCMA objects. See TRAU error manual at error AIS_ALARM_ON_LINK_A
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual.

##StartSpecProbl##
Specific Problems = 292 NOTIFIED AIS ALARM ON LINK B

Event Type = COMMUNICATION FAILURE EVENT Severity = MINOR Proposed Repair Actions = 15 CHECK CABLES, CONNECTIONS, LINE QUALITY

Originator = 4400 MDHLCDCDE, 4754 TDHTRDCMS Error notified by TRAU towards the BSC on PCMS/PCMA objects. See TRAU error manual at errorAIS_ALARM_ON_LINK_B.
aaaa = bbbb = See TRAU error manual. See TRAU error manual.

114

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = = = = = = = = = = See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual.

cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

Specific Problems = 307 NOTIFY PDT ALIGNMENT LOST

Event Type = COMMUNICATION FAILURE EVENT Severity = WARNING Proposed Repair Actions = 5 SEE THE PROPOSED ACTION IN THE MANUAL

Originator = 7211 PKTSABBPDS A PDT has been released. The cause is specified in cccc field. A check on the cables, connections and lines quality can be made. Check also the configuration established between BSC and BTS.
aaaa = bbbb = cccc = Process State. Process Instance (PDT index). EDOS Message Code: this field is associated to the release cause and can assume the following values: 0xce or 0x12: Internal Problems in PCUC/PCUX PDCH scheduler; 0x14: PDT alignment not reached 0x40: Frame Alignment in Progress: PDT alignment reached but lost; 0x41: Time Alignment in Progress: PDT alignment reached but lost; 0x43: Time Alignment Error: the PCUC/PCUX has received 3 even no consecutive PCU frames with signal "downlink frame errors detected by the BTS", without having at least two correct frames in between; 0x44: Block Number Internal Error: the AbIC reported that it has received a Block Number different from the one it was expecting; or two consecutive valid UL blocks received on the same PDT has not consecutive Block Number. 0x45: Frame Alignment Error: the AbIC has received 3 consecutive UL PCU frames which are affected by frame errors; 0x46: CRC Error: the PCUC/PCUX has received 3 even no consecutive PCU frames which are affected by CRC error, without having at least two correct frames in between. 0xce: Empty Queue: the Internal Queue of scheduled messages to be sent to AbIC has been found empty. Process Source Line. Not used. Not used. Not used. Not used. Not used.

dddd eeee ffff gggg hhhh iiii

= = = = = =

A30808-X3247-K240-3-7619

115

Outputs OML:BSC
jjjj kkkk llll mmmm nnnn oooo = = = = = =

Base Station Controller

Not used. BVCI TRX (1st byte) and TSL (2nd byte) of the BVCI where the problem occurred Not used. Not used. PPCU/PPXU involved (1st byte) and Process Sending Message (2nd byte).

116

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

17 LINK FAILURE
FAILURE EVENT REPORT: NAME = Probable cause = Specific Problems = Event Type = Event Time = Severity = Trend Indication = Notification Identifier = Correlated Notification Identifier = Related MO = Proposed Repair Actions = Additional Text = Originator = Additional Words =
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo <R.T.D.>

<R.T.D.> <R.T.D.> Link Failure <see legend> <see legend> <R.T.D.> <see legend> <R.T.D.> <R.T.D.> <displayed only during Alarm Alignment> <R.T.D.> <R.T.D.> <see legend> <R.T.D.> <see legend>

Software Version =

Legend:

##StartSpecProbl##
Specific Problems = 068 AP CONNECTION FAILURE

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 7100 TL3RDALL A Connection Failure message was received.


aaaa bbbb cccc dddd = = = = Process Identifier (see annex D for more details) Process Instance Process State Cause. It can assume the following values: 1 = Radio Link Failure 2 = Handover access failure 18 = Timer T_MSRFPCI expired 28 = Remote transcoder failure PCMA and Time Slot number Cell Trx in the cell Channel Subchannel

eeee ffff gggg hhhh iiii

= = = = =

A30808-X3247-K240-3-7619

117

Outputs OML:BSC
jjjj kkkk llll mmmm nnnn oooo = = = = = = Channel type Pcu number (high part) and Pdt Number (low part) in case of GPRS call. Not Used Not Used Not Used Not Used

Base Station Controller

##StartSpecProbl##
Specific Problems = 182 OMAL DISCONNECTED

Event Type = COMMUNICATION FAILURE EVENT Severity = MAJOR Proposed Repair Actions = 1 NO ACTION

Originator = 4450 MDHIXDCSA This error occurs when the layer 7 of the OSI stack used to communicate with the OMC is down.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = the line number of the source module the number of the IXLT supporting the OMC link the bit coded value indicating the OSI levels state for the OMC part the error code that determined the crash of the OMC link (it is under the responsibility of the OMC group) data stored in the duam to debug omal behaviour ("fill[11]") data stored in the duam to debug omal behaviour ("fill[12]") data stored in the duam to debug omal behaviour ("fill[13]") data stored in the duam to debug omal behaviour ("fill[14]") data stored in the duam to debug omal behaviour ("fill[15]") data stored in the duam to debug omal behaviour ("fill[16]") data stored in the duam to debug omal behaviour ("fill[17]") data stored in the duam to debug omal behaviour ("fill[18]") data stored in the duam to debug omal behaviour ("fill[19]") data stored in the duam to debug omal behaviour ("fill[20]") data stored in the duam to debug omal behaviour ("fill[21]")

Originator = 4457 MDHIXDCSM this error occurs when the IXLT is going out of service and the OMC link supported cannot be recovered.
aaaa = bbbb = cccc = the line number of the source module the number of the IXLT supporting the OMC link not used.

118

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = = = = = = = = = not used. not used. not used. not used. not used. not used. not used. not used. not used. not used. not used. not used.

dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

##StartSpecProbl##
Specific Problems = 183 X25 DISCONNECTED

Event Type = COMMUNICATION FAILURE EVENT Severity = MAJOR Proposed Repair Actions = 1 NO ACTION

Originator = 4450 MDHIXDCSA This error occurs when the layer 2 of the X25 link is down.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = the line number of the source module the number of the IXLT supporting the link the bit coded value indicating the OSI levels state for the OMC part the error code that determined the crash of the X25 link (it is under the responsibility of the OMC group) data stored in the duam to debug x25 link behaviour ("fill[11]") data stored in the duam to debug x25 link behaviour ("fill[12]") data stored in the duam to debug x25 link behaviour ("fill[13]") data stored in the duam to debug x25 link behaviour ("fill[14]") data stored in the duam to debug x25 link behaviour ("fill[15]") data stored in the duam to debug x25 link behaviour ("fill[16]") data stored in the duam to debug x25 link behaviour ("fill[17]") data stored in the duam to debug x25 link behaviour ("fill[18]") data stored in the duam to debug x25 link behaviour ("fill[19]") data stored in the duam to debug x25 link behaviour ("fill[20]") data stored in the duam to debug x25 link behaviour ("fill[21]")

Originator = 4457 MDHIXDCSM this error occurs when the IXLT is going out of service and the X25 link supported cannot
A30808-X3247-K240-3-7619 119

Outputs OML:BSC

Base Station Controller

be recovered.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = the line number of the source module the number of the IXLT supporting the link not used. not used. not used. not used. not used. not used. not used. not used. not used. not used. not used. not used. not used.

##StartSpecProbl##
Specific Problems = 184 CBCL DISCONNECTED

Event Type = COMMUNICATION FAILURE EVENT Severity = MAJOR Proposed Repair Actions = 1 NO ACTION

Originator = 4450 MDHIXDCSA This error occurs when the layer 3 of the OSI stack used to communicate with the CBC is down.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = the line number of the source module the number of the IXLT supporting the CBC link the bit coded value indicating the OSI levels' state for the CBC part the error code that determined the crash of the CBC link (it is under the responsability of the OMC group) data stored in the duam to debug Cbcl link behaviour ("fill[11]") data stored in the duam to debug Cbcl link behaviour ("fill[12]") data stored in the duam to debug Cbcl link behaviour ("fill[13]") data stored in the duam to debug Cbcl link behaviour ("fill[14]") data stored in the duam to debug Cbcl link behaviour ("fill[15]") data stored in the duam to debug Cbcl link behaviour ("fill[16]") data stored in the duam to debug Cbcl link behaviour ("fill[17]") data stored in the duam to debug Cbcl link behaviour ("fill[18]") data stored in the duam to debug Cbcl link behaviour ("fill[19]") data stored in the duam to debug Cbcl link behaviour ("fill[20]") data stored in the duam to debug Cbcl link behaviour ("fill[21]")

120

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Originator = 4457 MDHIXDCSM this error occurs when the IXLT is going out of service and the CBC link supported cannot be recovered
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = the line number of the source module the number of the IXLT supporting the CBC link not used. not used. not used. not used. not used. not used. not used. not used. not used. not used. not used. not used. not used.

##StartSpecProbl##
Specific Problems = 185 CBCL DISCONNECTED FOR OVERLOAD

Event Type = COMMUNICATION FAILURE EVENT Severity = MAJOR Proposed Repair Actions = 1 NO ACTION

Originator = 4450 MDHIXDCSA This error occurs when the layer 3 of the OSI stack used to communicate with the CBC is down for the IXLT overload condition.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = the line number of the source module the number of the IXLT supporting the CBC link the bit coded value indicating the OSI levels' state for the CBC part the error code that determined the crash of the CBC link (it is under the responsability of the OMC group) data stored in the duam to debug Cbcl link behaviour ("fill[11]") data stored in the duam to debug Cbcl link behaviour ("fill[12]") data stored in the duam to debug Cbcl link behaviour ("fill[13]") data stored in the duam to debug Cbcl link behaviour ("fill[14]") data stored in the duam to debug Cbcl link behaviour ("fill[15]") data stored in the duam to debug Cbcl link behaviour ("fill[16]") data stored in the duam to debug Cbcl link behaviour ("fill[17]") data stored in the duam to debug Cbcl link behaviour ("fill[18]") data stored in the duam to debug Cbcl link behaviour ("fill[19]") data stored in the duam to debug Cbcl link behaviour ("fill[20]") data stored in the duam to debug Cbcl link behaviour ("fill[21]")

A30808-X3247-K240-3-7619

121

Outputs OML:BSC

Base Station Controller

##StartSpecProbl##
Specific Problems = 269 LINK DOWN

Event Type = COMMUNICATION FAILURE EVENT Severity = MAJOR Proposed Repair Actions = 15 CHECK CABLES, CONNECTIONS, LINE QUALITY

Originator = 4802 TDHLPDCEN This error occurs when the device handler of the LAPD links detects a permanent failure of the specified logical link (LPDL). The error is notified if the disconnection persists more than a predefined threshold period.
aaaa = bbbb = source code line (developer oriented) Current value of the finite state machine (FSM): CDHLP_OOS = 0x00 The link is released and the LPDL operational state is DISABLED. This is the initial state after the link creation, or it reaches this state after an unrecovered link release. CDHLP_INIT = 0x01 The device handler received the establishment indication from layer 2 and wait few msec to filter the initial LAPD transitions: in this period the LPDL state is set to ENABLED Initializing. CDHLP_FILTERING = 0x02 This state gives the possibility to filter eventually a temporary link transition. If the link restarts in a few time, the LPDL device handler does not report any operational state transition to Status Manager. CDHLP_MONITOR = 0x03 This is the normal operating condition of the link: established with the operational state set to ENABLED. Event managed by the LAPD DH: CDHLP_TMOUT = 0 tmout occurred CDHLP_ESTABL = 1 link established CDHLP_RELEAS = 2 ink released CDHLP_SMENBL = 3 SM ENABLE command CDHLP_SMDSBL = 4 SM DISABLE command Link disconnection's probable cause (L2Err): Received when the L2 Status = 1 or 4: NO VALUE 0xFF MDL ERROR RESPONSE MESSAGE 0x00 MDL REMOVE REQUEST MESSAGE 0x01 Received when the L2 Status = 7: DM FRAME RECEIVED 0x02 TIMER T200 EXPIRED 0x03 MDL REMOVE REQUEST MESSAGE 0x04 Received when the L2 Status = 8: DISC FRAME RECEIVED 0x05 MDL REMOVE REQUEST MESSAGE 0x06 Layer 2 protocol status: 1 = TEI unassigned 2 = Assign awaiting TEI 3 = Establish awaiting TEI 4 = TEI assigned 5 = Awaiting Establishment 6 = Awaiting Release 7 = Multiple Frame Established 8 = Timer Recovery. Not used.

cccc =

dddd =

eeee =

ffff =

122

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = = = = = = Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

Originator = 4953 TDHGPIHGB This error occurs when the FR layer 2 notifies a protocol failure.
aaaa = bbbb = the line number of the source module the cause of FRL link down: 0x00 - FR_LINK_ACTIVE 0x01 - FR_LINK_FAIL 0x02 - FR_LINK_OFFLINE 0x03 - FR_LINK_INIT GbIC prc state: 0xFF - GB_NOT_CREATED 0x00 - GB_INITIALIZING 0x01 - GB_ACTIVE 0x02 - GB_FAILURE 0x03 - GB_BLOCKED 0x04 - GB_UNBLOCKED 0x05 - GB_PVC_FAIL 0x06 - GB_SETTING 0x07 - GB_DELETING 0xFE - GB_ERROR GbIC ope state: 0xFF - GB_NULL 0x01 FRL_OFFLINE 0x02 FRL_IDLE 0x03 FRL_ACTIVE GbIC prot state: 0xFF - FRL_NOT_CREATED 0x00 - FRL_CREATING 0x01 - FRL_INITIALIZING_PH 0x02 - FRL_INITIALIZING_LINK 0x03 - FRL_ACTIVE_WAITING_STATUS 0x04 - FRL_ACTIVE_POLLING_COMPLETE 0x05 - FRL_FAILURE_WAITING_STATUS 0x06 - FRL_FAILURE_POLLING_COMPLETE 0x07 - FRL_CHANGING_ATTRIBUTES 0x08 - FRL_CHANGING_PH_CONFIGURATION 0x09 - FRL_DELETING 0xFE FRL_ERROR Not used Not used Not used Not used Not used Not used Not used Not used Not used

cccc =

dddd =

eeee =

ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn

= = = = = = = = =

A30808-X3247-K240-3-7619

123

Outputs OML:BSC
oooo = Not used

Base Station Controller

Specific Problems = 271 NSVC CONNECTION FAILURE

Event Type = COMMUNICATION FAILURE EVENT Severity = MINOR Proposed Repair Actions = 15 CHECK CABLES, CONNECTIONS, LINE QUALITY

Originator = 4953 TDHGPIHGB This error occurs when the NS layer of the Gb interface fails.
aaaa = bbbb = the line number of the source module the cause of NS link down: 0x04 - PVC_LINK_ACTIVE 0x05 - PVC_LINK_FAIL 0x06 - NS_LINK_ALIVE 0x07 - NS_LINK_UNBLOCKED 0x08 - NS_LINK_BLOCKED 0x09 - OM_UNBLOCK_OK 0x0A - OM_BLOCK_OK 0x0B - NS_LINK_DEAD 0x0C - NS_TEST_FAIL 0x0D - NS_RESET_REQUEST 0x0E - OM_BLOCK_FAIL GbIC prc state: 0xFF - GB_NOT_CREATED 0x00 - GB_INITIALIZING 0x01 - GB_ACTIVE 0x02 - GB_FAILURE 0x03 - GB_BLOCKED 0x04 - GB_UNBLOCKED 0x05 - GB_PVC_FAIL 0x06 - GB_SETTING 0x07 - GB_DELETING 0xFE - GB_ERROR GbIC ope state: 0xFF - GB_NULL 0x04 - NSVC_LOCAL_NOT_AVAILABLE 0x05 - NSVC_REMOTE_NOT_AVAILABLE 0x06 - NSVC_ALIVE GbIC prot state: 0xFF - NSVC_NOT_CREATED 0x00 - NSVC_CREATING 0x01 - NSVC_ATTACHING_LINK 0x02 - NSVC_PVC_LINK_WAITING 0x03 - NSVC_PVC_LINK_FAILURE 0x04 - NSVC_DEAD_INITIALIZING 0x05 - NSVC_DEAD_BLOCKING 0x06 - NSVC_DEAD_BLOCKED 0x07 - NSVC_ALIVE_BLOCKED 0x08 - NSVC_ALIVE_UNBLOCKING 0x09 - NSVC_ALIVE_BLOCKING 0x0A - NSVC_ALIVE_UNBLOCKED 0x0B - NSVC_CHANGING_ATTRIBUTES 0x0C - NSVC_DETACHING_LINK 0x0D - NSVC_DELETING 0xFE - NSVC_ERROR

cccc =

dddd =

eeee =

124

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = = = = = = = Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used

ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

A30808-X3247-K240-3-7619

125

Outputs OML:BSC

Base Station Controller

18 LOSS OF SYNCHRONIZATION
FAILURE EVENT REPORT: NAME = Probable cause = Specific Problems = Event Type = Event Time = Severity = Trend Indication = Notification Identifier = Correlated Notification Identifier = Related MO = Proposed Repair Actions = Additional Text = Originator = Additional Words =
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo <R.T.D.>

<R.T.D.> <R.T.D.> Loss Of Synchronization <see legend> <see legend> <R.T.D.> <see legend> <R.T.D.> <R.T.D.> <displayed only during Alarm Alignment> <R.T.D.> <R.T.D.> <see legend> <R.T.D.> <see legend>

Software Version =

Legend:

##StartSpecProbl##
Specific Problems = 139 SYNCHRONISM OF PLLH ERROR

Event Type = EQUIPMENT FAILURE EVENT Severity = MINOR Proposed Repair Actions = 21 CREATE A NEW SYNC (SYNE)

Originator = 4206 MDHNWDCDE, 4208 MDHNWDCSY The synchronism source (SYNC or SYNE) that was synchronizing the pllh master is degraded or has been switched off, so that the PLLH has gone spontaneously in free running mode. If XXXX = 4206 MDHNWDCDE, it means that a previous call of this error, or of another error that puts the object in disable, has been lost, and the present call is to clear the consequent data base inconsistency.
aaaa = bbbb = (Developer oriented) Source code line where the error occurerd value of the pllh alarm register (*). The following codes can be logically OR-ed: 0x1 (bit 0): If this bit is set, the PLLH is distributing its own clock signal to the peripheral cards, otherwise it is distributing the clocks of the other PLLH 0x2 (bit 1): the input external synchronism is missing 0x4 (bit 2): the output clock is missing 0x8 (bit 3): the input external source to be measured is missing 0x10 (bit 4): the PLLH is not synchronized with the other PLLH 0x20 (bit 5): address parity alarm on UBEX bus

126

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
0x40 (bit 6): data parity alarm on UBEX bus 0x80 (bit 7): watch dog alarm on the local processor Internal FW code of the PLLH (*): 0x1=>VCXO voltage out of range 0x2=>PLL unlocked 0x3=>Excessive jitter on synchronization source 0x4=>absence of the synchronization source 0x5=>last command from MPCC has not been understood 0x6=>VCXO voltage in the pre-alarm range 0x7=>interruption of the synchronization source 0x8=>eprom checksum failure 0x9=>fault on the DAC or on the ADC 0xA=>fault in the phase comparator 0xD=>CIOA fault (only PLLH V2) K (where fr. err = K*10(-E)): base of the last frequency error measured for that source (*) E (where fr. err = K*10(-E)): exponent of the last frequency error measured for that source. (*) TUNE word of master PLLH (*) DAC word of master PLLH (*) TUNE word of slave PLLH (if standby network is disabled, this value can be meaningless) (*) DAC word of slave PLLH (if standby network is disabled, this value can be meaningless) (*) Copy of PLLH that is working as master (0/1) (*) Edition of the 2 PLLH (0=659-7/0035x <x=B,C>, 1=PLLH V1, 2=PLLH V2). In the low byte, there is the edition of this PLLH, in the high byte the edition of other copy. (*) Frequency in KHz of the synchronization source (*) Phase error measured on the PLLH. The 16th bit is the sign bit; the lowest 15 bits are the absolute value (i.e. without sign) of the phase error. This value is expressed in units of 40 ns. Phase error (see previous word) measured by the other PLLH. It may be not meaningful if this PLLH is out of service. (*) not used N O T E: (*) not used if XXXX = 4206 MDHNWDCDE

cccc =

dddd = eeee = ffff = gggg = hhhh = iiii = jjjj = kkkk = llll = mmmm = nnnn = oooo =

##StartSpecProbl##
Specific Problems = 140 SYNC LINK ERROR

Event Type = EQUIPMENT FAILURE EVENT Severity = MINOR Proposed Repair Actions = 21 CREATE A NEW SYNC (SYNE)

Originator = 4208 MDHNWDCSY The TRAU whose SYNC was synchronizing the BSC is no longer able to provide to the BSC the clock from the MSC. This can be due to several reasons: either the loss of the LPDLS link, or a layer 1 error of the PCMS, or a problem in the A-interface that causes the availability of the SYNCT object of the TRAU. However, when the problem is due to errors of the PCMS or of the LPDLS, other alarms are issued on OMC/LMT for these objects, explaining the real origin of the problem.
aaaa = bbbb = (developer oriented) source code line where the error has been called value of the pllh alarm register. The following codes can be logically OR-ed: 0x1 (bit 0): If this bit is set, the PLLH is distributing its own clock signal to the peripheral cards, otherwise it is distributing the clocks of the other PLLH 0x2 (bit 1): the input external synchronism is missing 0x4 (bit 2): the output clock is missing 0x8 (bit 3): the input external source to be measured is missing

A30808-X3247-K240-3-7619

127

Outputs OML:BSC

Base Station Controller

cccc =

dddd eeee ffff gggg hhhh iiii jjjj

= = = = = = =

kkkk = llll = mmmm = nnnn = oooo =

0x10 (bit 4): the PLLH is not synchronized with the other PLLH 0x20 (bit 5): address parity alarm on UBEX bus 0x40 (bit 6): data parity alarm on UBEX bus 0x80 (bit 7): watch dog alarm on the local processor Internal FW error code of the PLLH: 0x1=>VCXO voltage out of range 0x2=>PLL unlocked 0x3=>Excessive jitter on synchronization source 0x4=>absence of the synchronization source 0x5=>last command from MPCC has not been understood 0x6=>VCXO voltage in the pre-alarm range 0x7=>interruption of the synchronization source 0x8=>eprom checksum failure 0x9=>fault on the DAC or on the ADC 0xA=>fault in the phase comparator 0xD=>CIOA fault (only PLLH V2) K (where fr. err = K*10(-E)): base of the last frequency error measured for that source E (where fr. err = K*10(-E)): exponent of the last frequency error measured for that source. TUNE word of master PLLH DAC word of master PLLH TUNE word of slave PLLH (if standby network is disabled, this value can be meaningless) DAC word of slave PLLH (if standby network is disabled, this value can be meaningless) Edition of the 2 PLLH (0=659-7/0035x <x=B,C>, 1=PLLH V1, 2=PLLH V2). In the low byte, there is the edition of this PLLH, in the high byte the edition of other copy. PLLH edition (0=659-7/0035x <x=B,C>, 1=PLLH V1, 2=PLLH V2) Frequency in KHz of the synchronization source Phase error measured on the PLLH. The 16th bit is the sign bit; the lowest 15 bits are the absolute value (i.e. without sign) of the phase error. This value is expressed in units of 40 ns. Phase error (see previous word) measured by the other PLLH. It may be not meaningful if this PLLH is out of service. not used

##StartSpecProbl##
Specific Problems = 141 PLLH VCXO OUT OF NORMAL RANGE

Event Type = EQUIPMENT FAILURE EVENT Severity = WARNING Proposed Repair Actions = 5 SEE THE PROPOSED ACTION IN THE MANUAL

Originator = 4205 MDHNWDCAL The control voltage of the clock generator of the PLLH is in the warning range, though there are not other alarms. Probably, the clock signal that is providing synchronism (SYNC or SYNE) has a frequency error around 1 Hz.
aaaa bbbb cccc dddd = = = = (developer oriented) code source line where error occurred TUNE word of the PLLH DAC word of the PLLH TUNE word of the other PLLH (if the other network is disabled, this value can be meaningless) DAC word of the other PLLH (if the other network is disabled, this value can be meaningless) Edition of the 2 PLLH (0=659-7/0035x <x=B,C>, 1=PLLH V1, 2=PLLH V2). In the lower byte, there is the edition of this PLLH, in the higher byte the edition of other copy. Type of active synchronization source: 44(0x2C): SYNC; 45(0x2D): SYNE; 0xFFFF: PLLH is free running

eeee = ffff = gggg =

128

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
Instance number of SYNC or SYNE that is active, or 0xFFFF if PLLH is free running. K (where fr. err = K*10(-E)): base of the last frequency error measured for the SYNC or SYNE that is active, or 0xFFFF if PLLH is free running. E (where fr. err = K*10(-E)): exponent of the last frequency error measured for the SYNC or SYNE that is active, or 0xFFFF if PLLH is free running. Frequency in KHz of the SYNC or SYNE that is providing service, or 0xFFFF if PLLH is free running. Phase error measured on the PLLH. The 16th bit is the sign bit; the lowest 15 bits are the absolute value (i.e. without sign) of the phase error. This value is expressed in units of 40 ns. Phase error (see previous word) measured by the other PLLH. It may be not meaningful if this PLLH is out of service. not used not used

hhhh = iiii = jjjj = kkkk = llll = mmmm = nnnn = oooo =

##StartSpecProbl##
Specific Problems = 142 SYNCHRONISM FAILED MEASUREMENT

Event Type = EQUIPMENT FAILURE EVENT Severity = WARNING Proposed Repair Actions = 5 SEE THE PROPOSED ACTION IN THE MANUAL

Originator = 4232 MDHPLSHHS The frequency measurement of the synchronism source that has been selected for synchronizing the PLLH does not fulfill the requirements. The reason for this can be related to either the source itself or to the aging of the PLLH.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii = = = = = = = = = (developer oriented) source code line where the error has been called base (or mantissa) of the relative frequency measurement exponent of the relative frequency measuremen [err = bbbb*10^(-cccc)] Tune word of the active PLLH DAC word of the active PLLH Tune word of the standby PLLH (not meaningful if the standby NTW is disabled) DAC word of the standby PLLH (not meaningful if the standby NTW is disabled) Copy of PLLH that is working as master (0/1) Edition of the 2 PLLH (0=659-7/0035x <x=B,C>, 1=PLLH V1, 2=PLLH V2). In the lower byte, there is the edition of this PLLH, in the higher byte the edition of other copy. Frequency in KHz of the synchronization source Phase error measured on the PLLH. The 16th bit is the sign bit; the lowest 15 bits are the absolute value (i.e. without sign) of the phase error. This value is expressed in units of 40 ns. Phase error (see previous word) measured by the other PLLH. It may be not meaningful if this PLLH is out of service. not used not used not used

jjjj = kkkk = llll = mmmm = nnnn = oooo =

Specific Problems = 152 SYNE WITHOUT SIGNAL

Event Type = EQUIPMENT FAILURE EVENT


A30808-X3247-K240-3-7619 129

Outputs OML:BSC

Base Station Controller

Severity = MINOR Proposed Repair Actions = 15 CHECK CABLES, CONNECTIONS, LINE QUALITY

Originator = 4232 MDHPLSHHS No signal is arriving to the jack for the sinusoidal synchronism source ("SYNE")
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = No. of the source code line where the error has been detected alarm register of the PLLH Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used

130

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

22 POWER SUPPLY FAILURE


FAILURE EVENT REPORT: NAME = Probable cause = Specific Problems = Event Type = Event Time = Severity = Trend Indication = Notification Identifier = Correlated Notification Identifier = Related MO = Proposed Repair Actions = Additional Text = Originator = Additional Words =
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo <R.T.D.>

<R.T.D.> <R.T.D.> POWER SUPPLY FAILURE <see legend> <see legend> <R.T.D.> <see legend> <R.T.D.> <R.T.D.> <displayed only during Alarm Alignment> <R.T.D.> <R.T.D.> <see legend> <R.T.D.> <see legend>

Software Version =

Legend:

##StartSpecProbl## Specific Problems = 0 347 EXTENDED RACK 48V COPY 0 FAILED Event Type = POWER SUPPLY FAILURE Severity = MAJOR Proposed Repair Actions = 1 NO ACTION

Originator = 4400 MDHLCDCDE This error occurred when a STLP in extende rack ( only new type rack, introduced from BR 6.02 ) detected a fault on 48 V power copy 0 ( line A)
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk = = = = = = = = = = = Line bit mask containing previous cards number which detected fault on 48V (line A) bit mask containing previous cards number which detected fault on 48V (line B) bit mask containing current cards number which detected fault on 48V (line A) bit mask containing current cards number which detected fault on 48V (line B) not used not used not used not used not used not used

A30808-X3247-K240-3-7619

131

Outputs OML:BSC
llll mmmm nnnn oooo = = = = not used not used not used not used

Base Station Controller

##StartSpecProbl##
Specific Problems = 348 EXTENDED RACK 48V COPY 1 FAILED

Event Type = POWER SUPPLY FAILURE Severity = MAJOR Proposed Repair Actions = 1 NO ACTION

Originator = 4400 MDHLCDCDE This error occurred when a STLP in extende rack ( only new type rack, introduced from BR 6.02 ) detected a fault on 48 V power line B (copy 1)
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Line bit mask containing previous cards number which detected fault on 48V (line A) bit mask containing previous cards number which detected fault on 48V (line B) bit mask containing current cards number which detected fault on 48V (line A) bit mask containing current cards number which detected fault on 48V (line B) not used not used not used not used not used not used not used not used not used not used

132

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

29 TRANSCEIVER PROBLEM
FAILURE EVENT REPORT: NAME = Probable cause = Specific Problems = Event Type = Event Time = Severity = Trend Indication = Notification Identifier = Correlated Notification Identifier = Related MO = Proposed Repair Actions = Additional Text = Originator = Additional Words =
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo <R.T.D.>

<R.T.D.> <R.T.D.> Transceiver Problem <see legend> <see legend> <R.T.D.> <see legend> <R.T.D.> <R.T.D.> <displayed only during Alarm Alignment> <R.T.D.> <R.T.D.> <see legend> <R.T.D.> <see legend>

Software Version =

Legend:

##StartSpecProbl##
Specific Problems = 066 NO CALL IN CELL WITHIN A PREDEFINED TIME FRAME

Event Type = QUALITY OF SERVICE FAILURE EVENT Severity = MINOR Proposed Repair Actions = 28 CHECK BARRING INFORMATION AND BTS HW

Originator = 7777 TL3SCELL This error occurs if no call in a cell has occurred for a predefined time frame. This is an indication of a potentially faulty cell. The following properties are configurable on per-cell base via O&M command : -enabled/disabled alarm detection - time frame for alarm detection (up to two different time zones - low and high traffic)
aaaa = bbbb = cccc = dddd = Cell number. 0 : Cell NOT barred by Data Base; 1 : Cell barred by Data Base. 0 : Cell NOT barred for overload or for SS7 fault; 1 : Cell barred for overload or for SS7 fault. Access class barring by Data Base. Considering the binary representation, each bit is an access class : 000000000000000 : all access class NOT barred.

A30808-X3247-K240-3-7619

133

Outputs OML:BSC
000000000000001 : access class 0 barred. 000000000000011 : access class 0 and 1 barred. ... 100000000000000 : access class 15 barred 111111111111111 : all access class barred. Access class barring by overload. Considering the binary representation, each bit is an access class : 000000000000000 : all access class NOT barred. 000000000000001 : access class 0 barred. 000000000000011 : access class 0 and 1 barred. ... 100000000000000 : access class 15 barred 111111111111111 : all access class barred. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

Base Station Controller

eeee =

ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

= = = = = = = = = =

Specific Problems = 070 NO CALL IN TRX WITHIN A PREDEFINED TIME FRAME

Event Type = QUALITY OF SERVICE FAILURE EVENT Severity = MINOR Proposed Repair Actions = 29 CHECK THE TRX HW

Originator = 7777 TL3SCELL The error occurs if no call in a TRX has for a predefined time frame. This is an indication of a potentially faulty TRX. The following properties are configurable on per-cell base via O&M command : - enabled/disabled alarm detection. - time frame for alarm detection (up to two different time zones - low and high traffic).
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Absolute TRX number. Cell number. TRX number within the cell. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

134

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

A30808-X3247-K240-3-7619

135

Outputs OML:BSC

Base Station Controller

37 DATABASE INCONSISTENCY
FAILURE EVENT REPORT: NAME = Probable cause = Specific Problems = Event Type = Event Time = Severity = Trend Indication = Notification Identifier = Correlated Notification Identifier = Related MO = Proposed Repair Actions = Additional Text = Originator = Additional Words =
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo <R.T.D.>

<R.T.D.> <R.T.D.> Database Inconsistency <see legend> <see legend> <R.T.D.> <see legend> <R.T.D.> <R.T.D.> <displayed only during Alarm Alignment> <R.T.D.> <R.T.D.> <see legend> <R.T.D.> <see legend>

Software Version =

Legend:

##StartSpecProbl##
Specific Problems = 013 TDPC DATABASE NOT CONSISTENT

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 2000 MDATABASE This error can occur in two differt situation: in COMMAND MODE, when the operator enters a command from LMT, the DBL on the TDPC processor is updated with the new values and the updating of the DBC on BSC is failed. In this case only aaaa and bbbb additional info are logged. Second scenario: a periodic audit check the consistency between DBC and DBL. If a mismatch is detected then additional information about (cccc-hhhh) wich network element is involved are logged. Note:For the corrispondence between the displayed numbers and the file identifiers, see ANNEX C.
aaaa bbbb cccc dddd eeee = = = = = line. file identifier btsm number error code. mnemonic object.

136

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = = = = = = = bts number. trx number chan number. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

##StartSpecProbl##
Specific Problems = 018 STATUS MANAGER DEVICE HANDLER AUDIT MISMATCH

Event Type = QUALITY OF SERVICE FAILURE EVENT Severity = MINOR Proposed Repair Actions = 1 NO ACTION

Originator = 3101 MSMSHADSA A mismatch between Status Manager /Device Handler state or Status Manager/Data Base equipment, about a managed object, has been detected. Corrective actions have been started.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii = = = = = = = = = Mnemonic Unit address[0] Unit address[1] Unit address[2] Unit address[3] Status Manager Administartive State Status Manager Operational State Not Used. If jjjj = 0 Status Manager StandBy Status If jjjj = 1 or 2 Not used. Audit Type discriminator: 0 = Status Manager - Device Handler state audit 1 or 2 = Staus Manager - Data Base equipment audit If jjjj = 0 Device Handler Administrative State If jjjj = 1 or 2 Not used. If jjjj = 0 Device Handler Operational State If jjjj = 1 or 2 Not used. If jjjj = 0 Hardware State If jjjj = 1 or 2 Not Used If jjjj = 0 Device Handler StandBy Status If jjjj = 1 or 2 Not Used Source code line.

jjjj = kkkk = llll = mmmm = nnnn = oooo =

##StartSpecProbl##
A30808-X3247-K240-3-7619 137

Outputs OML:BSC
Specific Problems = 027 DATABASE INCONSISTENCY WARNING

Base Station Controller

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 5 SEE THE PROPOSED ACTION IN THE MANUAL

Originator = 2000 MDATABASE The error occurs if an unforeseen arrives or if the updating of TDPC local data fails or if something fails during the transmission to LV3 of a frequency redefinition message. A periodic audit task check the consistency between DBC and DBL. If a mismatch is detected then additional information (cccc-hhhh) about wich network element is involved are logged.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Source C line where the error occurred Source C file identifier btsm number internal error code. mnemonic object bts number trx number channel number Not Used Not Used Not Used Not Used Not Used Not Used Not Used

Originator = 2222 CDBMDHSA The current object results not equipped or in wrong state within the data base table dhsa_fsm (ex: lock for a object not created)
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn = = = = = = = = = = = = = = Source C line Used by designer to indicate the instn value (Current number of SCA/RFLOOP object) Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used

138

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
Not used

oooo =

Originator = 2600 TDATABASE The error occurs if a not expected message arrives to the task.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used

Originator = 3111 MSMSHHDHT Status manager cant build the MNEMONIC or the UNIT ADDRESS of a superordinate object.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Source line number Mnemonic identifier source Unit address[0] Unit address[1] Unit address[2] Unit address[3] Superordinate identifier Unit address[0] Unit address[1] Unit address[2] Unit address[3] Mnemonic value of father retrieved from Entity table Chain value Not used Not used

A30808-X3247-K240-3-7619

139

Outputs OML:BSC

Base Station Controller

Originator = 3140 MSMSHPCCC Status Manager retrieved an invalid TIT entry value.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Source line number Mnemonic value Unit address[0] Unit address[1] Unit address[2] Unit address[3] Not used Not used Not used Not used Not used Not used Not used Not used Not used

Originator = 3143 MSMSHPCPI Status Manager doesnt update its database during a create of LPDL object.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Source line number Action Action result received from Device Handler Mnemonic Unit address[0] Unit address[1] Unit address[2] Unit address[3] Not used Not used Not used Not used Not used Not used Not used

Originator = 4202 MDHNWDCSC It has been requested to NTW Device Handler the creation of a NUC object, but the data that are provided by DBA for this object contain some inconsistency. The reason for it can
140 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

be understood from the additional words.


aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Source line of code where the error is issued Mnemonic entity code of the PCM line "to termination" (PCMB: 0x1F; PCMS: 0x22) Instance number of the PCM line "to termination" Auxiliary mnemonic entity code of the PCM line "to termination" (it should be PCML 0x21) No. of LICD where the PCM "to termination" is created No. of PCM couple on the LICD where the PCM "to termination" is created No. of trunk (0=A, 1=B) in the PCM couple where the PCM "to termination" is created Mnemonic entity code of the PCM line "from termination" (PCMB: 0x1F; PCMS: 0x22) Instance number of the PCM line "from termination" Auxiliary mnemonic entity code of the PCM line "from termination" (it should be PCML 0x21) No. of LICD where the PCM "from termination" is created No. of PCM couple on the LICD where the PCM "from termination" is created No. of trunk (0=A, 1=B) in the PCM couple where the PCM "from termination" is created Time slot (1--31) "to termination" on low byte; time slot "from termination" on high byte Source line of code where the error has been found

Originator = 4203 MDHNWININ This error reveals during initialization of both network copies at dedicated init.
aaaa = bbbb = cccc = Source line of code where the error is issued Parameter indicating if the database has been successfully loaded Network type present in the BSC database. Particularly results 0 if is a SN64 1 if is a SN16 2 if is a SNAP card PCM type. Particularly is 24 if it is a PCM24 31 if it is a PCM30 Asub enhanced capacity. 0 if it is FALSE 1 if it is TRUE Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used

dddd =

eeee =

ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

= = = = = = = = = =

Originator = 4351 MDHBCDCDE

A30808-X3247-K240-3-7619

141

Outputs OML:BSC

Base Station Controller

This define is used when a function of Bsc Controller found an invalid state in the local database. The additional info are not meaningful for the operator
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = local code error designed oriented. internal data designer oriented. source code line. Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used

Originator = 4352 MDHBCDCGI This define is used when a function of Bsc Controller found an invalid value in the response message from Status Manager, or in the allocated buffer where the upload service parks the data received from the Network Element.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = source code line designer oriented. internal data designer oriented. internal data designer oriented. internal data designer oriented. internal data designer oriented. Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used

142

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Originator = 4502 MDHXXDCEH This error message is issued by PPCC Device Handler if a software problem arises during PPCC database loading (Set MTL2, Create OPC commands and PPCC Initializations).
aaaa = Identifier of source item where error was found (1 = DHXXDCCH, 2 = DHXXDCDE, 3 = DHXXDCEH, 4 = DHXXDCSA, 5 = DHXXDCSM, 6 = DHXXDCTH, 7 = DHXXDDDI, 8 = DHXXDDHD, 9 = DHXXGSUT, 0x0a = DHXXINIT) Line number of source file where error was found. Error code (0x19 = Out Of Range). Line number of routine calling error handling function. High byte: third byte of PPCC answer Low byte: second byte of PPCC answer Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used

bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

= = = = = = = = = = = = = =

Originator = 4504 MDHXXDCSM This error message is issued in two cases: 1) when fdbca_getPpxxInfo DBA utility returns (for PPLD or PPCC) a value different from Equipped during a PPLD or PPCC Device Controller operation of card connection (Network and LICD setting). 2) when utility for Create / Delete LAPD link (HW operations on PPLD side) fails because DBA utility defines the link to be managed as not equipped
aaaa bbbb cccc dddd = = = = Source item identifier Source line number Error code (0x17) Case 1: value returned by fdbca_getPpxxInfo; case 2: absolute LPDL number inside database In case 1: absolute card number; in case 2: signal subtype inside internal message to DH (value 1 means LAPD Create, 2 means LAPD Delete). Only for case 1: logical PPLD number or PPCC number Only for case 1: total numer of links (according to DBA) Only for case 1: number of PPxx circuit (all circuits if 0xFF) Only for case 1: action to be done (1 = Connect Ppld and Ntw, 2 = connect Ppld only, 3 = disconnect Ppld) Not used Not used Not used Not used Not used Not used

eeee = ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = =

A30808-X3247-K240-3-7619

143

Outputs OML:BSC

Base Station Controller

Originator =

4503 MDHXXDCSA 4514 MDHXXLUSA

This error accours in two cases: 1- A call to Database Service Function has fail 2- A command not compatible with actual configuration has been received by PPXX DH
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = internal error code source line absolute card instance not used not used not used not used not used not used not used not used not used not used not used not used

Originator = 4707 TDHBFINIT The BTSM DH performs a consistency check in the internal database when a new functional object is created; when a disalignment is detected, this notification is reported..
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Line of module where the Error Collector is called internal error code (see dh_gs.h, dbcadh.h) Module in which the error occurred Line of module in which the error occurred object identifier (mnemonic) object identifier (first address) object identifier (second address) Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used

144

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Originator = 4758 TDHTRDCL3 The TRAU DH performs a consistency check between internal database state of tslt and shared table with LV3 radio. Whenever a mismatch is detected the TRAU DH retriggers the notification to LV3 radio in order to correct the inconsistency and notify it to the operator.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Line of module where the Error C ollector call is Pcma number Pcmt number LSB of TSLT mask MSB of TSLAT mask Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used

Originator = 4950 TDHGPCCIN When a request to create an object not concerning the GPRS functional ones, this error is emitted.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = module line of the error call Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used

Originator = 5000 CPM_MPCC_ORIGINATOR


A30808-X3247-K240-3-7619 145

Outputs OML:BSC

Base Station Controller

This message error is issued if an inconsistent scan state has been found, if an inconsistent request arrives from Status Manager , if the scanner device handler starts again ( after an abort ) in a critical zone or if a mismatch with an object of a measure arises. All related additional info are developer oriented and useful for debugging activity
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Module that generates the error. Source code line of the module that generates the error. Internal use. Internal use. Internal use.. Internal use.. Internal use. Internal use. Internal use. Internal use. Internal use.. Internal use. Internal use. Internal use.. Internal use..

Originator = 5001 CPM_IMSI_ORIGINATOR This message is issued by IMSI TRACING task when a problem in retrieving a database object occurs. All related additional info are developer oriented and useful for debugging activity
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Module that generates the error. Source code line of the module that generates the error. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use.

146

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Originator = 5002 CPM_CTR_ORIGINATOR This message is issued by CTR Tracing task when a problem in retrieving a database object occurs. All related additional info are developer oriented and useful for debugging activity
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Module that generates the error. Source code line of the module that generates the error. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use.

Originator = 5100 CPM_PCUC_ORIGINATOR This message is issued by PM GPRS task when a problem in retrieving a database object occurs. All related additional info are developer oriented and useful for debugging activity
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Module that generates the error. Source code line of the module that generates the error. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use.

A30808-X3247-K240-3-7619

147

Outputs OML:BSC

Base Station Controller

Originator = 5500 CPM_TDPC_ORIGINATOR TDPC performs a consistency check in the internal database regarding Performance Measures task. This error occurs if a disalignment is detected. All related additional info are developer oriented and useful for debugging activity
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Source module that generates the error; it can be 1, 2, 4 or 5. Source code line of the module that generates the error. Source code line of the module that generates the error. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use.

Originator = 7021 TL3N7HMRT1, 7025 TL3N7LMAC1, 7028 TL3N7TMSR1, 7032 TL3N7TMCB2, 7033 TL3N7TMCB3, 7034 TL3N7TMCB4, 7035 TL3N7TMCB5, 7036 TL3N7TMC01, 7038 TL3N7TMC03 This error is output when a database inconsistency is found during sharing table and routing table management.
aaaa bbbb cccc dddd = = = = Instance EDOS signal (see annex D for more details) Source C line where the error is occurred Error type. It can assume the following values (and, as consequence, the other words make sence): 1 MTP STMREADY EXPIRED 2 MTP WAITDATA2 EXPIRED 5 MTP SLS IS NOT CARRIED 6 MTP CONGESTION LEVEL CORRUPTED 8 MTP AVAILABLE LINK NOT FOUND eeee oooo = Not Used 4 MTP CANNOT INITIALIZE TABLE eeee = Number of engiineered links ffff oooo = Not Used 3 MTP SLS NOT FOUND 7 MTP SLS ROUTING TABLE INCONSISTENCY eeee = SLS ffff oooo = Not Used see "dddd" Additional Info see "dddd" Additional Info see "dddd" Additional Info see "dddd" Additional Info see "dddd" Additional Info see "dddd" Additional Info see "dddd" Additional Info

eeee ffff gggg hhhh iiii jjjj kkkk

= = = = = = =

148

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = see "dddd" Additional Info see "dddd" Additional Info see "dddd" Additional Info see "dddd" Additional Info

llll mmmm nnnn oooo

Originator = 7053 TL3N7TMFC1 This report means that the detected link congestion level is greater than the destinations one.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Instance EDOS signal (see annex D for more details) Source C line where the error is occurred 6 MTP CONGESTION LEVEL CORRUPTED Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used

##StartSpecProbl##
Specific Problems = 028 AP CIRCUIT POOL MISMATCH

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 5 SEE THE PROPOSED ACTION IN THE MANUAL

Originator = 7100 TL3RDALL The pool type associated to the PCMA (indicated by the received Circuit Identity Code) doesnt support the request of MSC.
aaaa bbbb cccc dddd eeee ffff gggg hhhh = = = = = = = = Process identifier (see annex D for more details) Process Instance Process State Not Used Process Source Line received CIC pool type associated to the PCMA(first byte), PCMA Id (second byte) Channel Type IE of the received request, coded as GSM 08.08

A30808-X3247-K240-3-7619

149

Outputs OML:BSC
iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = Channel Type IE of the received request, coded as GSM 08.08 Channel Type IE of the received request, coded as GSM 08.08 Channel Type IE of the received request, coded as GSM 08.08 Channel Type IE of the received request, coded as GSM 08.08 Not Used Not Used Not Used

Base Station Controller

##StartSpecProbl##
Specific Problems = 105 UNCOMPATIBLE BSC CONFIGURATION

Event Type = PROCESSING FAILURE EVENT Severity = CRITICAL Proposed Repair Actions = 12 CHECK THE CONFIGURATION/HW COMPATIBILITY

Originator = 4752 DHTRDCMC This alarm is output when he TRAU configuration is not correct.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = DBA utility result (developer oriented) configuration alarm flag in TRAU DH database (developer oriented) TRAU DH internal state of the finite state machine logic (developer oriented) TRAU DH database internal alarm status (developer oriented) Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

##StartSpecProbl##
Specific Problems = 176 LPDL LINK AUDIT MISMATCH

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 5 SEE THE PROPOSED ACTION IN THE MANUAL

Originator = 4802 TDHLPDCEN


150 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

The related link has changed its state from up to down or viceversa, but the LAPD DH found an inconsistency between the new state sent by Lapd Layer 2 and its database.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = source code line (originator oriented). Lapd Layer 2 new state (off/on) (developer oriented). lapd operational state in DH database (developer oriented). LAPD related NE (BTSM/TRAU) operational state in DH database (developer oriented) LAPD finite state machine in DH database (developer oriented). Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

##StartSpecProbl##
Specific Problems = 341 DATABASE NOT COMPATIBLE WITH ESUSW

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 5 SEE THE PROPOSED ACTION IN THE MANUAL

Originator = 507 MSDBASDL A SET BSCOSUSW attribute has been requested, but the BSCESUDB instance currently stored in the related attribute (backupESU, newESU or fallbackESU) for the object BSCOSUDB is not compatible with the involved BSCESUSW. It causes that the BSCESUDB instance is unlinked by the BSCOSUDB attribute (which is set to null value). A new compatible database instance should be assigned to it. It prevents the attempt to load a new MPCC executable software with an invalid database version.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to rebuild MPCC processor call stack. Used by the designer to rebuild MPCC processor call stack. Used by the designer to rebuild MPCC processor call stack. Used by the designer to rebuild MPCC processor call stack. Used by the designer to rebuild MPCC processor call stack. Used by the designer to rebuild MPCC processor call stack. Used by the designer to rebuild MPCC processor call stack. Used by the designer to rebuild MPCC processor call stack. Used by the designer to rebuild MPCC processor call stack. Used by the designer to rebuild MPCC processor call stack. Used by the designer to rebuild MPCC processor call stack. Used by the designer to rebuild MPCC processor call stack. Used by the designer to rebuild MPCC processor call stack. Used by the designer to rebuild MPCC processor call stack. Used by the designer to rebuild MPCC processor call stack.

A30808-X3247-K240-3-7619

151

Outputs OML:BSC

Base Station Controller

##StartSpecProbl##
Specific Problems = 344 TRAU AMR BUT POOLING DISABLED

Event Type = PROCESSING FAILURE EVENT Severity = CRITICAL Proposed Repair Actions = 12 CHECK THE CONFIGURATION/HW COMPATIBILITY

Originator = 4752 DHTRDCMC This alarm is output when he TRAU configuration is not correct.
aaaa bbbb cccc dddd eeee ffff = = = = = = source code line (developer oriented) result of the DBA function call that checks the Configuration event that determined the last alignment current state of main state machine current state of alignment state machine TRAU operational state from SM Note that this field also marks the existence of a certain instance, in case of not equipped instances the value is NO_OPERATIONAL_STATE (0). TRAU administrative state from SM TRAU operational state from Abis TRAU administrative state from Abis identifier for the PCMA alarm identifier for the PCMA temporary alarm control sequence of state audit of Asub (High part) control sequence of state audit of Asub (Low part) counter of the TRAU_FAILEDPROC events for filtering (High part) counter of the TRAU_FAILEDPROC events for filtering (Low part)

gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

= = = = = = = = =

152

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

38 FILE SYSTEM CALL UNSUCCESSFUL


FAILURE EVENT REPORT: NAME = Probable cause = Specific Problems = Event Type = Event Time = Severity = Trend Indication = Notification Identifier = Correlated Notification Identifier = Related MO = Proposed Repair Actions = Additional Text = Originator = Additional Words =
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo <R.T.D.>

<R.T.D.> <R.T.D.> File System Call Unsuccessful <see legend> <see legend> <R.T.D.> <see legend> <R.T.D.> <R.T.D.> <displayed only during Alarm Alignment> <R.T.D.> <R.T.D.> <see legend> <R.T.D.> <see legend>

Software Version =

Legend:

Specific Problems = 004 FILE SYSTEM OPERATION FAILURE

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 5 MOSFSIODF A file system operation, issued by the Delete File procedure, has failed.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to locate the instruction (line of third calling instruction, if any). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any). File system failure cause: 0003 Too Many Fs Clients 0005 Disk Full 0013 File In Use 0016 File Not Found

A30808-X3247-K240-3-7619

153

Outputs OML:BSC
0018 Directory Not Found 0020 Cross Copy In Progress 1100 Both Disk Copies Out Of Service Other: for designer use only. Not used. Not used. Not used. Not used. Not used. Not used.

Base Station Controller

jjjj kkkk llll mmmm nnnn oooo

= = = = = =

Originator = 6 MOSFSIODD During the display directory command it was not possible to activate successfully the Display_Dir() low level routine.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any) Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to locate the instruction (line of third calling instruction, if any). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any). File system failure cause: 0003 Too Many Fs Clients 0005 Disk Full 0013 File In Use 0016 File Not Found 0018 Directory Not Found 0020 Cross Copy In Progress 1100 Both Disk Copies Out Of Service Other: for designer use only. Not used. Not used. Not used. Not used. Not used. Not used.

jjjj kkkk llll mmmm nnnn oooo

= = = = = =

Originator = 122 MOSSDCFFS A file system operation, during the check of the 'Expected Sw Version' attribute, has failed.
aaaa bbbb cccc dddd = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any).

154

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = = Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to locate the instruction (line of third calling instruction, if any). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any). File system failure cause: 0003 Too Many Fs Clients 0005 Disk Full 0013 File In Use 0016 File Not Found 0018 Directory Not Found 0020 Cross Copy In Progress 1100 Both Disk Copies Out Of Service Other: for designer use only. Not used Not used Not used Not used Not used Not used

eeee ffff gggg hhhh iiii

jjjj kkkk llll mmmm nnnn oooo

= = = = = =

Originator = 124 MOSSDNDDL0 A file system operation, issued by the BTSE download task, has failed.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to locate the instruction (line of third calling instruction, if any). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any). File system failure cause: 0003 Too Many Fs Clients 0005 Disk Full 0013 File In Use 0016 File Not Found 0018 Directory Not Found 0020 Cross Copy In Progress 1100 Both Disk Copies Out Of Service Other: for designer use only. Not used Not used Not used Not used Not used Not used

jjjj kkkk llll mmmm nnnn oooo

= = = = = =

A30808-X3247-K240-3-7619

155

Outputs OML:BSC

Base Station Controller

Originator = 125 MOSSDNDDL1 A file system operation, issued by the TRAU download task, has failed.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to locate the instruction (line of third calling instruction, if any). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any). File system failure cause: 0003 Too Many Fs Clients 0005 Disk Full 0013 File In Use 0016 File Not Found 0018 Directory Not Found 0020 Cross Copy In Progress 1100 Both Disk Copies Out Of Service Other: for designer use only. not used. not used. not used. not used. not used. not used.

jjjj kkkk llll mmmm nnnn oooo

= = = = = =

Originator = 126 MOSSDNSBL A file system operation, issued by the BTSE alignment task, has failed.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to locate the instruction (line of third calling instruction, if any). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any). File system failure cause: 0003 Too Many Fs Clients 0005 Disk Full 0013 File In Use 0016 File Not Found 0018 Directory Not Found 0020 Cross Copy In Progress 1100 Both Disk Copies Out Of Service Other: for designer use only. Not used. Not used. Not used. Not used. Not used. Not used.

jjjj kkkk llll mmmm nnnn oooo

= = = = = =

156

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Originator = 127 MOSSDNSTL A file system operation, issued by the TRAU alignment task, has failed.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to locate the instruction (line of third calling instruction, if any). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any). File system failure cause: 0003 Too Many Fs Clients 0005 Disk Full 0013 File In Use 0016 File Not Found 0018 Directory Not Found 0020 Cross Copy In Progress 1100 Both Disk Copies Out Of Service Other: for designer use only. Not used. Not used. Not used. Not used. Not used. Not used.

jjjj kkkk llll mmmm nnnn oooo

= = = = = =

Originator = 128 MOSSDNSBC A file system operation, issued by the BTSE activation task, has failed.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to locate the instruction (line of third calling instruction, if any). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any). File system failure cause: 0003 Too Many Fs Clients 0005 Disk Full 0013 File In Use 0016 File Not Found 0018 Directory Not Found 0020 Cross Copy In Progress

A30808-X3247-K240-3-7619

157

Outputs OML:BSC
1100 Both Disk Copies Out Of Service Other: for designer use only. Not used. Not used. Not used. Not used. Not used. Not used.

Base Station Controller

jjjj kkkk llll mmmm nnnn oooo

= = = = = =

Originator = 129 MOSSDNSTC A file system operation, issued by the TRAU activation task, has failed.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to locate the instruction (line of third calling instruction, if any). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any). File system failure cause: 0003 Too Many Fs Clients 0005 Disk Full 0013 File In Use 0016 File Not Found 0018 Directory Not Found 0020 Cross Copy In Progress 1100 Both Disk Copies Out Of Service Other: for designer use only. Not used Not used Not used Not used Not used Not used

jjjj kkkk llll mmmm nnnn oooo

= = = = = =

Originator = 130 MOSSDFSMS, 132 MOSSDFSCS During a move or copy sw command it was not possible to activate a file system service.
aaaa bbbb cccc dddd eeee ffff gggg = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to locate the instruction (line of third calling instruction, if any). Used by the designer to locate the instruction (file id of fourth calling instruction, if any).

158

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
Used by the designer to locate the instruction (line of fourth calling instruction, if any). File system failure cause: 0003 Too Many Fs Clients 0005 Disk Full 0013 File In Use 0016 File Not Found 0018 Directory Not Found 0020 Cross Copy In Progress 1100 Both Disk Copies Out Of Service Other: for designer use only. Not used. Not used. Not used. Not used. Not used. Not used.

hhhh = iiii =

jjjj kkkk llll mmmm nnnn oooo

= = = = = =

Originator = 131 MOSSDFSRS A file system operation, issued by the Get SW Version procedure, failed.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to locate the instruction (line of third calling instruction, if any). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any). File system failure cause: 0003 Too Many Fs Clients 0005 Disk Full 0013 File In Use 0016 File Not Found 0018 Directory Not Found 0020 Cross Copy In Progress 1100 Both Disk Copies Out Of Service Other: for designer use only. Not used. Not used. Not used. Not used. Not used. Not used.

jjjj kkkk llll mmmm nnnn oooo

= = = = = =

Originator = 133 MOSSDFSDS During a download from the LMT/OMC to the BSC, the download task could not activate a file system service.
A30808-X3247-K240-3-7619 159

Outputs OML:BSC
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii = = = = = = = = =

Base Station Controller

jjjj kkkk llll mmmm nnnn oooo

= = = = = =

Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to locate the instruction (line of third calling instruction, if any). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any). File system failure cause: 0003 Too Many Fs Clients 0005 Disk Full 0013 File In Use 0016 File Not Found 0018 Directory Not Found 0020 Cross Copy In Progress 1100 Both Disk Copies Out Of Service Other: for designer use only. Not used. Not used. Not used. Not used. Not used. Not used.

Originator = 136 MOSSDFSUD During an upload from the BSC to the LMT/OMC, the upload task could not activate a file system service.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to locate the instruction (line of third calling instruction, if any). Used by the designer to locate the instruction (file id of fourth calling instruction, if any) Used by the designer to locate the instruction (line of fourth calling instruction, if any). File system failure cause: 0003 Too Many Fs Clients 0005 Disk Full 0013 File In Use 0016 File Not Found 0018 Directory Not Found 0020 Cross Copy In Progress 1100 Both Disk Copies Out Of Service Other: for designer use only. Not used. Not used. Not used. Not used. Not used. Not used.

jjjj kkkk llll mmmm nnnn oooo

= = = = = =

160

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Originator = 304 MOSICELWR, 320 MOSICCLWR A File System function, called by BSC Logging task, failed.
aaaa = - Error code returned by File System, if bbbb = 0000 or 0001 or 0002 or 0003 or 0005 or 0006; - The .LOG file instance currently in use, if bbbb = 0008 or 0009. Used by designer to identify context in which fault occurred; its value can be: - 0000; - 0001; - 0002; - 0003; - 0005; - 0006; - 0008; - 0009. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

bbbb =

cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

= = = = = = = = = = = = =

Originator = 315 MOSICLFUP A File System function, called by BSC Upload of proprietary log files task, failed.
aaaa = Used by the designer as an internal error code; its value can be: - 0008 (.LOG file not found); - 0009 (.UPL file not deleted); - 000B (invalid control record). Number of the source code line where error was issued. - The .LOG file instance which cannot be found, if aaaa = 0008; - Transfer identifier (most significant word), if aaaa = 0009 or 000B. - Transfer identifier (most significant word), if aaaa = 0008; - Transfer identifier (least significant word), if aaaa = 0009 or 000B. - Transfer identifier (least significant word), if aaaa = 0008; - I/O source value of I/O header, if aaaa = 0009 or 000B. Current value of errno. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

bbbb = cccc = dddd = eeee = ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn = = = = = = = = =

A30808-X3247-K240-3-7619

161

Outputs OML:BSC
oooo = Not used.

Base Station Controller

Originator = 317 MOSICIWAS A file system operation, issued by the Interworking Alarm Summary task while performing a Get_Alarm_Event_Condition SBS command, has failed.
aaaa = bbbb = Code line where the error was detected. File system failure cause: 0003 Too Many Fs Clients 0005 Disk Full 0013 File In Use 0016 File Not Found 0018 Directory Not Found 0020 Cross Copy In Progress 1100 Both Disk Copies Out Of Service Other: for designer use only. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

= = = = = = = = = = = = =

Originator = 500 MSDLSLTPI, 501 MSDLSLTPL, 502 MSDLSLTPP, 503 MSDLSLTPT, 600 MSDBACTDA, 601 MSDBACTMT, 603 MSDBACTMA, 604 MSDBACTIA 605 MSDBACTPA, 606 MSDBACTTA, 700 TOSSDATPL During a loading process (at Bring Up or Dedicated Load) it was not possible to activate a file system service.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to locate the instruction (line of third calling instruction, if any). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any). File system failure cause: 0003 Too Many Fs Clients

162

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
0005 Disk Full 0013 File In Use 0016 File Not Found 0018 Directory Not Found 0020 Cross Copy In Progress 1100 Both Disk Copies Out Of Service Other: for designer use only. Not used. Not used. Not used. Not used. Not used. Not used.

jjjj kkkk llll mmmm nnnn oooo

= = = = = =

Originator = 505 MSDSMCTMA One of the file system function, called by compression task, failed.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to lacate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to lacate the instruction (line of third calling instruction). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any). Number of file. Number of file system error. Not used. Not used. Not used. Not used. Not used.

Originator = 622 MSDRIBSHF One of the file system function, called by BSC Remote Inventory task, failed:
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii = = = = = = = = = error checkpoint (used to identify the logical code line where the error occurred). file system failure error code internal return code from file system (file pointer) internal return code from file system Not used. Not used. Not used. Not used. Not used.

A30808-X3247-K240-3-7619

163

Outputs OML:BSC
jjjj kkkk llll mmmm nnnn oooo = = = = = = Not used. Not used. Not used. Not used. Not used. Not used.

Base Station Controller

Originator = 5000 CPM_MPCC_ORIGINATOR This error message is issued when a reporting, inhibit or allow operation has failed All related additional info are developer oriented and useful for debugging activity .
aaaa bbbb cccc dddd = = = = Module that generates the error: Source code line of the module that generates the error. Internal use. File system failure cause: 0003 Too Many Fs Clients 0005 Disk Full 0013 File In Use 0016 File Not Found 0018 Directory Not Found 0020 Cross Copy In Progress 1100 Both Disk Copies Out Of Service Other: for designer use only. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use.

eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

= = = = = = = = = = =

Originator = 5001 CPM_IMSI_ORIGINATOR One of the file system function, called by IMSI Tracing task, failed: All related additional info are developer oriented and useful for debugging activity .
aaaa bbbb cccc dddd = = = = Module that generates the error: Source code line of the module that generates the error. Internal use. Internal use.

164

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = = = = = = = = Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use.

eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

Originator = 5002 CPM_CTR_ORIGINATOR One of the file system function, called by CTR Tracing task, failed: All related additional info are developer oriented and useful for debugging activity .
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Module that generates the error: Source code line of the module that generates the error. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use.

Originator = 10102 MFTRS A file system call performed by ftrs (FTAM responder) task failed
aaaa = bbbb = cccc dddd eeee ffff = = = = designer oriented: an integher identifieng the module where the file system call originating the error is performed designer oriented: the line (hex value) within the module the module where the file system call originating the error is performed Not used. Not used. Not used. Not used.

A30808-X3247-K240-3-7619

165

Outputs OML:BSC
gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

Base Station Controller

Originator = 10106 MBAMA A file system call performed by the MIT aligner task failed
aaaa = bbbb = cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = designer oriented: an integher identifieng the module where the file system call originating the error is performed designer oriented: the line (hex value) within the module the module where the file system call originating the error is performed Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

Originator = 10106 MBAMA A file system call performed by the MIT aligner task failed
aaaa = bbbb = cccc dddd eeee ffff gggg hhhh iiii = = = = = = = designer oriented: an integher identifieng the module where the file system call originating the error is performed designer oriented: the line (hex value) within the module the module where the file system call originating the error is performed return value of the failed system call Not used. Not used. Not used. Not used. Not used. Not used.

166

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = = = Not used. Not used. Not used. Not used. Not used. Not used.

jjjj kkkk llll mmmm nnnn oooo

Originator = 10107 MBAAW A file system call performed by the Agent Worker task failed
aaaa = bbbb = cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = designer oriented: an integher identifieng the module where the file system call originating the error is performed designer oriented: the line (hex value) within the module the module where the file system call originating the error is performed Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

Originator = 10107 MBAAW A file system call performed by the Agent Worker task failed
aaaa = bbbb = cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm = = = = = = = = = = = designer oriented: an integher identifieng the module where the file system call originating the error is performed designer oriented: the line (hex value) within the module the module where the file system call originating the error is performed return value of the failed system call Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

A30808-X3247-K240-3-7619

167

Outputs OML:BSC
nnnn = oooo = Not used. Not used.

Base Station Controller

168

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

39 INPUT PARAMETER OUT OF RANGE


FAILURE EVENT REPORT: NAME = Probable cause = Specific Problems = Event Type = Event Time = Severity = Trend Indication = Notification Identifier = Correlated Notification Identifier = Related MO = Proposed Repair Actions = Additional Text = Originator = Additional Words =
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo <R.T.D.>

<R.T.D.> <R.T.D.> Input Parameter Out Of Range <see legend> <see legend> <R.T.D.> <see legend> <R.T.D.> <R.T.D.> <displayed only during Alarm Alignment> <R.T.D.> <R.T.D.> <see legend> <R.T.D.> <see legend>

Software Version =

Legend:

##StartSpecProbl##
Specific Problems = 025 INPUT PARAMETER OUT OF RANGE WARNING

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 133 MOSSDFSDS The message sent by the LMT/OMC to activate a download toward the BSC contains a wrong parameter or a parameter which is not consistent with the others.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj = = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to locate the instruction (line of third calling instruction, if any). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any). not used. not used.

A30808-X3247-K240-3-7619

169

Outputs OML:BSC
kkkk llll mmmm nnnn oooo = = = = = not used. not used. not used. not used. not used.

Base Station Controller

Originator = 136 MOSSDFSUD The message sent by the LMT/OMC to activate an upload from the BSC contains a wrong parameter or a parameter which is not consistent with the others.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to locate the instruction. not used. not used. not used. not used. not used. not used. not used. not used. not used. not used. not used. not used. not used. not used.

Originator = 305 MOSICILEM An invalid message has been received by the MPCC interface task that collect errors coming from IXLT software.
aaaa = bbbb = cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm = = = = = = = = = = = internal checkpoint used by designers. task instance that received the invalid message; it can only assume value 0 or 1 according to IXLT copy that it interfaces. not used. not used. not used. not used. not used. not used. not used. not used. not used. not used. not used.

170

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
not used. not used.

nnnn = oooo =

Originator = 318 MOSICUSSC One of the messages sent to the Upload Server task contains a wrong parameter or a parameter which is not consistent with the others.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to lacate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to lacate the instruction (line of third calling instruction). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any). Used by the designer. Used by the designer. Used by the designer. Used by the designer. Used by the designer. Used by the designer. not used.

Originator = 502 MSDLSLTPP One of the messages sent to the PPXX loader task contains a wrong parameter or a parameter which is not consistent with the others.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction). Used by the designer to locate the instruction (line of second calling instruction). Used by the designer to locate the instruction (file id of third calling instruction). Used by the designer to locate the instruction (line of third calling instruction). Used by the designer to locate the instruction (file id of fourth calling instruction). Used by the designer to locate the instruction (line of fourth calling instruction). Not used. Not used. Not used. Not used. Not used. Not used. Not used.

A30808-X3247-K240-3-7619

171

Outputs OML:BSC

Base Station Controller

Originator = 505 MSDSMCTMA One of the messages sent to the Compression task contains a wrong parameter or a parameter which is not consistent with the others.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to lacate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to lacate the instruction (line of third calling instruction). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any). number of file or operation code. not used. not used. not used. not used. not used. not used.

Originator = 700 TOSSDATPL The activation message of a PPXX loading on TDPC contains a bad processor type.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to locate the instruction (line of third calling instruction, if any). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any). not used. not used. not used. not used. not used. not used. not used.

172

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Originator = 2000 MDATABASE The error occurs when the expected buffer doesn't contain the GSM TIME ID. Note. For the correspondence between the displayed numbers and the file identifiers, see ANNEX C.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = line file identifier not used not used not used not used not used not used not used not used not used not used not used not used not used

Originator = 2222 CDBMDHSA This error is issued in these possible cases: 1) Invalid value of current instance of object SCA,RFLOOP,BSCAN. 2) Invalid event
aaaa = bbbb = Source C line Depends on the source C line this fiel could be: 1) Not used 2) Used by the designer to indicate an invalid current value current object during the set of timeout 3) Used by the designer to indicate an invalid address of current object BSCAN 4) Used by the designer to indicate a mnemonic related to an invalid instance of current object 5) Used bt the designer to indicate an invalind intance of current object during a manual upload request 6) Used by the designer to indicate an invalid result of function obj_ToBscan 7) Used by the designer to indicate an invalid event value Depends on the source C line this field could be: 1) Not used 2) Used by the designer to indicate a mnemonic related to an invalid BSCAN 3) Used by the designer to indicate the address[0] of an invalid current obiect 4) Used by the designer to indicate the file_type related a manual upload of an invalid current object Depends on the source C line this field could be: 1) Not used 2) Used by the designer to indicate the address[1] of invalid current obiect 3) Used by the designer to indicate the file_subtype[0] related a manual upload of an invalid current object Depends on the source C line this field could be: 1) Not used 2) Used by the designer to indicate the address[2] of invalid current obiect 3) Used by the designer to indicate the file subtype[1] related a manual upload of an

cccc =

dddd =

eeee =

A30808-X3247-K240-3-7619

173

Outputs OML:BSC
ffff =

Base Station Controller

gggg =

hhhh iiii jjjj kkkk llll mmmm nnnn oooo

= = = = = = = =

invalid current object Depends on the source C line this field could be: 1) Not used 2) Used by the designer to indicate the address[3] of invalid current obiect 3) Used by the designer to indicate the file_subtype[2] related a manual upload of an invalid current object Depends on the source C line this field could be: 1) Not used 2) Used by the designer to indicate the file_subtype[3] related a manual upload of an invalid current object Not used Not used Not used Not used Not used Not used Not used Not used

Originator = 2600 TDATABASE The task performing the recovery procedure on TDPC receive a wrong recovery type.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = not used not used not used not used not used not used not used not used not used not used not used not used not used not used not used

Originator = 3000 MSMARECCO, 3500 TSMARECCO Error ceased on MPCC or TDPC received an error ceased message buffer with an unknown action. The processing of the message received cannot continue.
aaaa bbbb cccc dddd = = = = source code line number mnemonic of the object involved first addres of the object involved second address of the object involved

174

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = = = = = = = = third address of the object involved fourth address of the object involved error identifier of the input message not used not used not used not used not used not used not used not used

eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

Originator = 3101 MSMSHADSA This define is used when audit function receives wrong state values from Device Handler or from Status Manager Database.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = <source line> <me_id.me_mnemonic> <me_id.me_address[0]> <me_id.me_address[1]> <me_id.me_address[2]> <me_id.me_address[3]> <sm_state(administrative and operational)> <hw_state> <dh_state(administrative and operational)> not used not used not used not used not used not used

Originator = 3130 MSMSHPIRM This define is used to show that one or more field of input buffer are not corrects.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii = = = = = = = = = Source line Signal type Signal subtype Transition index Action Mnemonic Unit address[0] Unit address[1] Unit address[2]

A30808-X3247-K240-3-7619

175

Outputs OML:BSC
jjjj kkkk llll mmmm nnnn oooo = = = = = = Unit address[3] Result not used not used not used not used

Base Station Controller

Originator = 4305 MDH40IOSC One of the messages sent to the DK40 Device Handler task contains a wrong parameter or a parameter which is not consistent with the others.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction). Used by the designer to locate the instruction (file id of second calling instruction). Used by the designer to locate the instruction (file id of third calling instruction). Used by the designer to locate the instruction (file id of third calling instruction). Used by the designer to locate the instruction (file id of fourth calling instruction). Used by the designer to locate the instruction (file id of fourth calling instruction). Used by the designer to identify the task status Used by the designer to identify the task status Used by the designer to identify the task status Used by the designer to identify the task status Used by the designer to identify the task status Used by the designer to identify the task status Used by the designer to identify the task status

Originator = 4451 MDHIXDCMC this error occurs when a parameter coming from other tasks to Device Handler is invalid.
aaaa = bbbb = the line number of the source module the error code (see include file DHIXDC.H) 1 = IXLT_INV_SIGNAL 2 = IXLT_INV_MNEMO 4 = IXLT_INV_CMD 9 = IXLT_CMD_TABLE_BUSY designer reserved. designer reserved. designer reserved. not used. not used. not used. not used. not used. not used.

cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk

= = = = = = = = =

176

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = not used. not used. not used. not used.

llll mmmm nnnn oooo

Originator = 4453 MDHIXININ this error occurs when an invalid initialization level was passed to the IXLT initialization procedure by the operating system.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = the initialization level. not used. not used. not used. not used. not used. not used. not used. not used. not used. not used. not used. not used. not used. not used.

Originator = 4457 MDHIXDCSM this error occurs when a status change about IXLT has to be performed but a parameter coming from Status Manager is invalid.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = the line number of the source module the error code indicating the kind of invalid parameter the mnemonic value the copy value the action value the signal subtype value not used. not used. not used. not used. not used. not used. not used. not used. not used.

A30808-X3247-K240-3-7619

177

Outputs OML:BSC

Base Station Controller

Originator = 4500 MDHXXDCCH This warning is generated if inside routine sending Ack message to BSC Agent proc_type field is not MM_PPLD nor MM_PPCC nor MM_PPCU.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = command bit mask of requested cards uncorrect proc_type not used not used not used not used not used not used not used not used not used not used not used not used

Originator = 4501 MDHXXDCDE This error message is issued if a SW error is returned by a routine implementing a command received by PPxx Device Controller.
aaaa = identifier of source file where the problem took place (1 = DHXXDCCH, 2 = DHXXDCDE, 3 = DHXXDCEH, 4 = DHXXDCSA, 5 = DHXXDCSM, 6 = DHXXDCTH, 7 = DHXXDDDI, 8 = DHXXDDHD, 9 = DHXXGSUT, 0x0a = DHXXINIT) line of source file (where the problem happened) Device Handler error code (0x0d = unexpected object instance, 0x0e = unexpected signal type, 0x15 = table of BSC Agent commands (to PPxx DH) is busy, 0x17 = card not stopped (not Offline) source system of command (0 = MPCC, 1 = TDPC) signal type signal subtype not used not used not used not used not used not used not used not used not used

bbbb = cccc =

dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

= = = = = = = = = = = =

178

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Originator = 4504 MDHXXDCSM This error is issued when an uncorrect input arrives from Status Manager task to PPXX Device Handler.
aaaa = source item where the problem took place (1 = DHXXDCCH, 2 = DHXXDCDE, 3 = DHXXDCEH, 4 = DHXXDCSA, 5 = DHXXDCSM, 6 = DHXXDCTH, 7 = DHXXDDDI, 8 = DHXXDDHD, 9 = DHXXGSUT, 10 = DHXXINIT, 11 = DGHDXXDP, DHXXDDPU = 12) source line where the problem was found error code (0x0E = Unexpected Signal Sigtype; 0x10 = Invalid Status Manager Action) line where utility was called absolute card number (0-14 -> PPLD 0-14; 15-16 -> PPCC 0-1; 17-20 -> PPCU 0-3) not used not used not used not used not used not used not used not used not used not used

bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

= = = = = = = = = = = = = =

Originator =

4503 MDHXXDCSA 4514 MDHXXLUSA

This error accours when a message containing an invalid field value as been received by PPXX DH.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = internal error code souce code line absolute card istance not used not used not used not used not used not used not used not used not used not used not used not used

A30808-X3247-K240-3-7619

179

Outputs OML:BSC

Base Station Controller

Originator = 5002 CPM_CTR_ORIGINATOR This message is issued by CTR Tracing task if one of the input parameters for a function is out of range. All related additional info are developer oriented and useful for debugging activity
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Module that generates the error. Source code line of the module that generates the error. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use.

Originator = 5100 CPM_PCUC_ORIGINATOR The error occurs if one of the input parameters for a function is out of range. All related additional info are developer oriented and useful for debugging activity
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Module that generates the error. Source code line of the module that generates the error. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use.

180

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Originator = 5500 CPM_TDPC_ORIGINATOR The error occurs if one of the input parameters for a function is out of range. All related additional info are developer oriented and useful for debugging activity
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Module that generates the error. Source code line of the module that generates the error. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use.

Originator = 8000 MNCPCMHIP Sw error type. This error indicates that Network Controller has received a message from Level 3 Radio with inconsistence of information (typically, out of range values).
aaaa = bbbb = cccc = Source line code where error was issued message discriminator (it should be 3) message type: 0XB4 = New call setup or hand over 0XB0 = Call release message counter value for call processing software no. of PCMA no. of TSLA no. of TRX mask containing information for the radio channel number request cause (meaningful only if cccc = 0XB4): 1= New call assignment 2= Hand over external to BSC 3= Hand over internal to BSC (inter/intra-cell) message counter value for Network controller not used not used not used not used not used

dddd eeee ffff gggg hhhh iiii

= = = = = =

jjjj kkkk llll mmmm nnnn oooo

= = = = = =

A30808-X3247-K240-3-7619

181

Outputs OML:BSC

Base Station Controller

Originator = 8002 MNCANMHIA Sw error type. This error shows that Network Controller has received a request ,that requires a semipermanent connection reconfiguration, with erroneous information.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = (designer oriented): source code line where error was issued (designer oriented): signal type (designer oriented): other fields of the wrong message not used not used not used not used not used not used not used not used not used not used not used not used

Originator = 9003 MDGDMPEPR, 9005 TDGDMPEPR It will be issued during diagnosis execution process if process receives an activation request in which diagnosis parameters are not correct.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = <source line> < instance> < mnemonic > not used not used not used not used not used not used not used not used not used not used not used not used

182

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

##StartSpecProbl##
Specific Problems = 041 INVALID SPECIFIC PROBLEM IN ERROR CALL

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 3000 MSMARECCO, 3500 TSMARECCO Error collector/ceased on MPCC or TDPC received an unknown error identifier (error_id) in the input buffer. In the following we name as original failure, the failure during the processing of which the error arised.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Originator of the original failure. Source code line number of error collector module. Error collector/ceased internal error. Error identifier of the original failure. Not used. Object mnemonic identifier of the original failure. Object first address of the original failure. Object second address of the original failure. Object third address of the original failure. Object fourth address of the original failure. Not used. Not used. Not used. Not used. Not used.

Originator = 3011 MSMAREPCO Error processor on MPCC received an unknown error identifier (error_id) in the input buffer. In the following we name as original error ceased, the module during the processing of which the error arised.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Source code number of error processor Error identifier relative to the original fault. Mnemonic of the object relative to the original fault. First address of the object relative to the original fault. Second address of the object relative to the original fault. Third address of the object relative to the original fault. Fourth address of the object relative to the original fault. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

A30808-X3247-K240-3-7619

183

Outputs OML:BSC

Base Station Controller

##StartSpecProbl##
Specific Problems = 042 INVALID OBJECT IDENTIFIER IN ERROR CALL

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 3000 MSMARECCO, 3500 TSMARECCO Error collector/ceasaed on MPCC or TDPC received an unknown maintenance entity identifier in the input buffer. In the following we name as original failure, the failure during the processing of which the error arised.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Originator of the original failure. Source Code line of error collector module. Error Collector/Ceased internal error Error identifier of the original failure Not used. Object mnemonic identifier of the original failure. Object first unit address of the original failure. Object second unit address of the original failure. Object third unit address of the original failure. Object fourth unit address of the original failure. Not used. Not used. Not used. Not used. Not used.

Originator = 3011 MSMAREPCO Error processor on MPCC received an unknown maintenance entity identifier in the input buffer. In the following we name as original error ceased, the module during the processing of which the error arised.
aaaa bbbb cccc dddd eeee ffff gggg hhhh = = = = = = = = Originator of the original error ceased. Source Code line of error processor module. Error identifier of the original failure Mnemonic identifier of the object relative to the original failure. First address of the object relative to the original failure Second address of the object relative to the original failure. Third address of the object relative to the original failure. Fourth address of the object relative to the original failure.

184

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = = = = Not used Not used Not used Not used Not used Not used Not used

iiii jjjj kkkk llll mmmm nnnn oooo

##StartSpecProbl##
Specific Problems = 054 AP A-BIS TIMER FAULT

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 7100 TL3RDALL Requested A-bis timer was not equipped.


aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Process Identifier (see annex D for more details) Process Instance Process State Not Used Process Source Line Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used

##StartSpecProbl##
Specific Problems = 056 AP CELL OVERFLOW

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 7100 TL3RDALL


A30808-X3247-K240-3-7619 185

Outputs OML:BSC

Base Station Controller

Reading/ Updating database error: the cell index offset was out of range.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Process Identifier (see annex D for more details) Process Instance Process State Not used Process Source Line Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used

##StartSpecProbl##
Specific Problems = 074 AP CHANNEL OVERFLOW

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 7100 TL3RDALL Reading / Updating database error: the channel index offset is out of range.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Process Identifier (see annex D for more details) Process Instance Process State Not Used Process Source Line Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used

186

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Originator = 7208 PKTSPRMPCH Reading / Updating internal error: the channel index offset is out of range.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Process State Process Instance EDOS Message Code. Process Source Line. Procedure Module Originator. Procedure Module Line. Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used PPCU/PPXU involved (1st byte) and Process Sending Message (2nd byte).

##StartSpecProbl##
Specific Problems = 077 AP CONNECTION OVERFLOW

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 7100 TL3RDALL Reading / Updating database error: the SCCP connection index is out of range.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Process Identifier (see annex D for more details) Process Instance Process State Not Used Process Source Line Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used

A30808-X3247-K240-3-7619

187

Outputs OML:BSC

Base Station Controller

##StartSpecProbl##
Specific Problems = 079 AP ID2MBIT OVERFLOW

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 7100 TL3RDALL Reading / Udpating database error: the PCM index offset is out of range.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Process Identifier (see annex D for more details) Process Instance Process State Not Used Process Source Line Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used

##StartSpecProbl##
Specific Problems = 087 AP MODE OVERFLOW

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 7100 TL3RDALL The mode discriminator of cell in BSC is not an allowed one.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj = = = = = = = = = = Process Identifier (see annex D for more details) Process Instance Process State Not Used Process Source Line Not Used Not Used Not Used Not Used Not Used

188

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = = Not Used Not Used Not Used Not Used Not Used

kkkk llll mmmm nnnn oooo

##StartSpecProbl##
Specific Problems = 098 AP SUBCHANNEL OVERFLOW

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 7100 TL3RDALL Reading / Updating database error : the sub-channel index offset is out of range.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Process Identifier (see annex D for more details) Process Instance Process State Not Used Process Source Line Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used

##StartSpecProbl##
Specific Problems = 099 AP TRX OVERFLOW

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 7100 TL3RDALL

A30808-X3247-K240-3-7619

189

Outputs OML:BSC

Base Station Controller

Reading / Updating database error : the TRX index offset is out of range.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Process Identifier (see annex D for more details) Process Instance Process State Not Used Process Source Line Not Used Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

Originator = 7208 PKTSPRMPCH, 7210 PKTSPRMPFR, 7211 PKTSABBPDS Reading / Updating internal error: the TRX index offset is out of range.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Process State Process Instance EDOS Message Code. Process Source Line. Procedure Module Originator. Procedure Module Line. Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used PPCU/PPXU involved (1st byte) and Process Sending Message (2nd byte).

##StartSpecProbl##
Specific Problems = 100 AP TERRESTRIAL TIME SLOT OVERFLOW

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 7100 TL3RDALL


190 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Reading / Updating database error : the index offset of PCM-A Slot is out of range.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Process Identifier (see annex D for more details) Process Instance Process State Not Used Process Source Line Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used

##StartSpecProbl##
Specific Problems = 104 AP HW CIRCUIT IDENTITY CODE OVERFLOW

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 7100 TL3RDALL Reading / Updating database error : the index offset of Circuit Identity Code is out of range.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Process Identifier (see annex D for more details) Process Instance Process State Not Used Process Source Line Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used

A30808-X3247-K240-3-7619

191

Outputs OML:BSC

Base Station Controller

##StartSpecProbl##
Specific Problems = 275 AP BVC OVERFLOW

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 7100 TL3RDALL Reading/ Updating database error: the BVC index offset was out of range.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Process Identifier (see annex D for more details) Process Instance Process State Not used Process Source Line Bvc index Not used Not used Not used Not used Not used Not used Not used Not used Not used

Originator = 7200 PKINRMMRMD, 7201 PKINOMMGMD, 7203 PKINABMABD, 7204 PKPMUTBUTC, 7204 PKPMUTBUTC, 7207 PKPMDTBDTM, 7208 PKTSPRMPCH, 7209 PKTSPRMPPM, 7210 PKTSPRMPRF. A message with a wrong BVCI is managed.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Process State. Process Instance. EDOS Message Code. Process Source Line. Procedure Module Originator. Procedure Module Line. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. PPCU/PPXU involved (1st byte) and Process Sending Message (2nd byte).

192

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

##StartSpecProbl##
Specific Problems = 277 AP PCU OVERFLOW

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 7100 TL3RDALL Reading/ Updating database error: the PCU index offset was out of range.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Process Identifier (see annex D for more details) Process Instance Process State Not used Process Source Line PCU index Not used Not used Not used Not used Not used Not used Not used Not used Not used

##StartSpecProbl##
Specific Problems = 279 AP PDT OVERFLOW

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 7100 TL3RDALL Reading/ Updating database error: the PDT index offset was out of range.
aaaa bbbb cccc dddd eeee ffff gggg = = = = = = = Process Identifier (see annex D for more details) Process Instance Process State Not used Process Source Line PCU index PDT index

A30808-X3247-K240-3-7619

193

Outputs OML:BSC
hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = Not used Not used Not used Not used Not used Not used Not used Not used

Base Station Controller

Originator = 7203 PKINABMABD, 7208 PKTSPRMPCH, 7210 PKTSPRMPFR, 7215 PKUTBMBGPG. A message with wrong PDT has been managed.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Process State. Process Instance. EDOS Message Code. Process Source Line. Procedure Module Originator. Procedure Module Line. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. PPCU/PPXU involved (1st byte) and Process Sending Message (2nd byte).

Specific Problems = 281 AP PCU TIMER FAULT

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 7100 TL3RDALL Requested PCU timer was not equipped.


aaaa bbbb cccc dddd eeee ffff = = = = = = Process Identifier (see annex D for more details) Process Instance Process State Not Used Process Source Line Not Used

194

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = = = = = = Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used

gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

A30808-X3247-K240-3-7619

195

Outputs OML:BSC

Base Station Controller

41 INVALID POINTER
FAILURE EVENT REPORT: NAME = Probable cause = Specific Problems = Event Type = Event Time = Severity = Trend Indication = Notification Identifier = Correlated Notification Identifier = Related MO = Proposed Repair Actions = Additional Text = Originator = Additional Words =
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo <R.T.D.>

<R.T.D.> <R.T.D.> Invalid Pointer <see legend> <see legend> <R.T.D.> <see legend> <R.T.D.> <R.T.D.> <displayed only during Alarm Alignment> <R.T.D.> <R.T.D.> <see legend> <R.T.D.> <see legend>

Software Version =

Legend:

##StartSpecProbl##
Specific Problems = 023 INVALID POINTER WARNING

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 5 SEE THE PROPOSED ACTION IN THE MANUAL

Originator = 313 MOSICILPD The pointer to the buffer related to a message whose reassembling has been stopped inBSC T-interface packet splitting task, is invalid.
aaaa = bbbb = cccc = Used by the designer as an internal error code; its value is: 0001 (pointer not found in list). Number of the source code line where error was issued. Job number identifying the message to reassemble.

196

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = = = = = = = = = Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

Originator = 410 MOSKNMSEH, 901 TOSKNMSEH This error is generated many times as described below.
aaaa = 0x0E BAD TMC LINK timing cell queues error 0x0F BAD SUSP LINK suspended task queue error 0x10 SCHED ERR scheduler error 0x15 UNDECLARED FUNCTION call to undeclared function 0x16 NULL POINT assignement through a null pointer If aaaa=0x15 than contains the task entry point. If aaaa=0x16 than contains data segment dump from offset 0. If "aaaa"=0x15 than contains the "task entry point". If "aaaa"=0x16 than contains data segment dump from offset 0. If "aaaa"=0x15 than contains the "call stack". If "aaaa"=0x16 than contains data segment dump from offset 0. If "aaaa"=0x15 than contains the "call stack". If "aaaa"=0x16 than contains data segment dump from offset 0. If "aaaa"=0x15 than contains the "call stack". If "aaaa"=0x16 than contains data segment dump from offset 0. If "aaaa"=0x15 than contains the "call stack". If "aaaa"=0x16 than contains data segment dump from offset 0. If "aaaa"=0x15 than contains the "call stack". If "aaaa"=0x16 than contains data segment dump from offset 0. If "aaaa"=0x15 than contains the "call stack". If "aaaa"=0x16 than contains data segment dump from offset 0. If "aaaa"=0x15 than contains the "call stack". If "aaaa"=0x16 than contains data segment dump from offset 0. If "aaaa"=0x15 than contains the "call stack". If "aaaa"=0x16 than contains data segment dump from offset 0. If "aaaa"=0x15 than contains the "call stack". If "aaaa"=0x16 than contains data segment dump from offset 0. If "aaaa"=0x15 than contains the "call stack". If "aaaa"=0x16 than contains data segment dump from offset 0. If "aaaa"=0x15 than contains the "call stack". If "aaaa"=0x16 than contains data segment dump from offset 0. If "aaaa"=0x15 than contains the "call stack". If "aaaa"=0x16 than contains data segment dump from offset 0.

bbbb = cccc = dddd = eeee = ffff = gggg = hhhh = iiii = jjjj = kkkk = llll = mmmm = nnnn = oooo =

Originator = 410 MOSKNMSEH, 901 TOSKNMSEH


A30808-X3247-K240-3-7619 197

Outputs OML:BSC

Base Station Controller

This error is generated many times as described below.


aaaa bbbb cccc dddd eeee ffff gggg hhhh = = = = = = = = 0x028 MSG POOL ERROR pool number requested by m_get_block(low byte) link type (high byte) pool number (low byte) source sys (high byte) dest sys (low byte) flags (high byte) source mbx (low byte) destination (high byte) signal type signal subtype datalen From the high byte of "bbbb" to "hhhh" the information is related to the fields of the message, that the procedure "m_get_block" is managing. 0 or the same value of the low byte of "bbbb" If the low byte of "iiii" is not zero, from the high byte of "iiii" to "oooo" there are the same values of "bbbb""hhhh" related to the previous message in the pool. Not used. Not used. Not used. Not used. Not used. Not used.

iiii =

jjjj kkkk llll mmmm nnnn oooo

= = = = = =

Originator = 410 MOSKNMSEH, 901 TOSKNMSEH This error is generated many times as described below.
aaaa = 0x8013 call stack related to the Initialization Completed message 0x8014 call stack related to the Current Task Deleted message 0x801D call stack related to the Deleted Current Init Function message 0x8814 call stack related to the deletion of the task, wich caused an initialization (1st message) information of the current task (2nd message) 0x0A13 call stack related to the first deletion in the interrupt handlers loop. 0x0C13 call stack related to the last deletion in the interrupt handlers loop. call stack call stack call stack call stack call stack call stack call stack call stack call stack call stack call stack call stack call stack call stack

bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

= = = = = = = = = = = = = =

198

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Originator = 410 MOSKNMSEH, 901 TOSKNMSEH This error is generated many times as described below.
aaaa = bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = 0x0B13 current task information related to the first deletion in the interrupt handlers loop. 0x0D13 current task information related to the last deletion in the interrupt handlers loop. Entry point of the deleted task (low word) Entry point of the deleted task (medium word) Entry point of the deleted task (high word) Interrupt number The value of the CS register The value of the IP register (low word) The value of the IP register (high word) The value of the FS register The value of the GS register The value of the AX register (low word) The value of the AX register (high word) The value of the BX register (low word) The value of the BX register (high word) not used

Originator = 2000 MDATABASE The error occurs if the pub dimensions are exceeded. Note. For the corrispondence between the displayed numbers and the file identifiers, see ANNEX C.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = line file identifier not used not used not used not used not used not used not used not used not used not used not used not used not used

Originator = 2600 TDATABASE


A30808-X3247-K240-3-7619 199

Outputs OML:BSC

Base Station Controller

The error occurs if the pub dimensions are exceeded.


aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Source C line File identifier. Its value is 0x001E (DBLAUTPH_FILE) Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used

Originator = 5500 CPM_TDPC_ORIGINATOR The error occurs if there is a pointer internal corruption.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer as an internal error code, its value is c. Source module that generates the error collector; its value is 4. Source code line of the module that generates the error. This field idicates the scanner number or internal use. Internal use. not used not used not used not used not used not used not used not used not used not used

Originator = 8888 TFSEDMSG A possible buffer corruption has been detected.


aaaa bbbb cccc dddd eeee = = = = = originator process process instance process state destination process message code

200

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = = = = = = = message length message pointer pool number not used not used not used not used not used not used not used

ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

Originator = 10108 MQ3CB A pointer to data buffer is invalid


aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = (developer oriented) source module (developer oriented) number of source module line not used not used not used not used not used not used not used not used not used not used not used not used not used

Specific Problems = 024 INVALID POINTER FULL INITIALIZATION

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 410 MOSKNMSEH/ 901 TOSKNMSEH An interrupt occured and the system as a defense action is trying to delete the current task when a second interrupt occurs generating a task abort loop. The informations about the current task are shown in the following messages.
aaaa = bbbb = cccc = 0x1F FULL INIT RQ not used not used

A30808-X3247-K240-3-7619

201

Outputs OML:BSC
dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = not used not used not used not used not used not used not used not used not used not used not used not used

Base Station Controller

202

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

42 MESSAGE NOT EXPECTED


FAILURE EVENT REPORT: NAME = Probable cause = Specific Problems = Event Type = Event Time = Severity = Trend Indication = Notification Identifier = Correlated Notification Identifier = Related MO = Proposed Repair Actions = Additional Text = Originator = Additional Words =
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo <R.T.D.>

<R.T.D.> <R.T.D.> Message Not Expected <see legend> <see legend> <R.T.D.> <see legend> <R.T.D.> <R.T.D.> <displayed only during Alarm Alignment> <R.T.D.> <R.T.D.> <see legend> <R.T.D.> <see legend>

Software Version =

Legend:

##StartSpecProbl##
Specific Problems = 040 UNEXPECTED MESSAGE RECEIVED ERROR

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 5 MOSFSIODF A corrupt delete file message has been received from LMT/OMC
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk = = = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction). Used by the designer to locate the instruction (line of second calling instruction). Used by the designer to locate the instruction (file id of third calling instruction). Used by the designer to locate the instruction (line of third calling instruction). Used by the designer to locate the instruction (file id of fourth calling instruction). Used by the designer to locate the instruction (line of fourth calling instruction). Not used. Not used. Not used.

A30808-X3247-K240-3-7619

203

Outputs OML:BSC
llll mmmm nnnn oooo = = = = Not used. Not used. Not used. Not used.

Base Station Controller

Originator = 6 MOSFSIODD A corrupt display dir message has been received from LMT/OMC.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction). Used by the designer to locate the instruction (line of second calling instruction). Used by the designer to locate the instruction (file id of third calling instruction). Used by the designer to locate the instruction (line of third calling instruction). Used by the designer to locate the instruction (file id of fourth calling instruction). Used by the designer to locate the instruction (line of fourth calling instruction). Not used. Not used. Not used. Not used. Not used. Not used. Not used.

Originator = 124 MOSSDNDDL0 A message received by the BTSE download task wasnt one of the NE messages.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction). Used by the designer to locate the instruction (line of second calling instruction). Used by the designer to locate the instruction (file id of third calling instruction). Used by the designer to locate the instruction (line of third calling instruction). Used by the designer to locate the instruction (file id of fourth calling instruction). Used by the designer to locate the instruction (line of fourth calling instruction). Message source system. Signal type. Signal subtype. ABIS, ASUB, LMT or OMC operation code. NE identifier. Not used. Not used.

204

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Originator = 125 MOSSDNDDL1 A message received by the TRAU download task wasnt one of the NE messages.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction). Used by the designer to locate the instruction (line of second calling instruction). Used by the designer to locate the instruction (file id of third calling instruction). Used by the designer to locate the instruction (line of third calling instruction). Used by the designer to locate the instruction (file id of fourth calling instruction). Used by the designer to locate the instruction (line of fourth calling instruction). Message source system. Signal type. Signal subtype. ABIS, ASUB, LMT or OMC operation code. NE identifier. Not used. Not used.

Originator = 126 MOSSDNSBL A message received by the BTSE alignment task wasnt one of the NE alignment.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction). Used by the designer to locate the instruction (line of second calling instruction). Used by the designer to locate the instruction (file id of third calling instruction). Used by the designer to locate the instruction (line of third calling instruction). Used by the designer to locate the instruction (file id of fourth calling instruction). Used by the designer to locate the instruction (line of fourth calling instruction). Message source system. Signal type. Signal subtype. ABIS, ASUB, LMT or OMC operation code. NE identifier. Not used. Not used.

A30808-X3247-K240-3-7619

205

Outputs OML:BSC

Base Station Controller

Originator = 127 MOSSDNSTL A message received by the TRAU alignment wasnt one of the NE alignment.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction). Used by the designer to locate the instruction (line of second calling instruction). Used by the designer to locate the instruction (file id of third calling instruction). Used by the designer to locate the instruction (line of third calling instruction). Used by the designer to locate the instruction (file id of fourth calling instruction). Used by the designer to locate the instruction (line of fourth calling instruction). Message source system. Signal type. Signal subtype. ABIS, ASUB, LMT or OMC operation code. NE identifier. Not used. Not used.

Originator = 128 MOSSDNSBC A message received by the BTSE activation procedure on the BSC wasnt one of the NE activation messages.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction). Used by the designer to locate the instruction (line of second calling instruction). Used by the designer to locate the instruction (file id of third calling instruction). Used by the designer to locate the instruction (line of third calling instruction). Used by the designer to locate the instruction (file id of fourth calling instruction). Used by the designer to locate the instruction (line of fourth calling instruction). Message source system. Signal type. Signal subtype. ABIS, ASUB, LMT or OMC operation code. NE identifier. Not used. Not used.

Originator = 129 MOSSDNSTC A message received by the TRAU activation procedure on the BSC wasnt one of the NE activation messages.
206 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = = = = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction). Used by the designer to locate the instruction (line of second calling instruction). Used by the designer to locate the instruction (file id of third calling instruction). Used by the designer to locate the instruction (line of third calling instruction). Used by the designer to locate the instruction (file id of fourth calling instruction). Used by the designer to locate the instruction (line of fourth calling instruction). Message source system. Signal type. Signal subtype. ABIS, ASUB, LMT or OMC operation code. NE identifier. Not used. Not used.

aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

Originator = 133 MOSSDFSDS A wrong message type has been received in some phase of the download procedure from LMT/OMC on the BSC.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction). Used by the designer to locate the instruction (line of second calling instruction). Used by the designer to locate the instruction (file id of third calling instruction). Used by the designer to locate the instruction (line of third calling instruction). Used by the designer to locate the instruction (file id of fourth calling instruction). Used by the designer to locate the instruction (line of fourth calling instruction). Not used. Not used. Not used. Not used. Not used. Not used. Not used.

Originator = 135 MOSSDFSMF A wrong message type has been received by file system task.
aaaa bbbb cccc dddd eeee ffff = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction). Used by the designer to locate the instruction (line of second calling instruction). Used by the designer to locate the instruction (file id of third calling instruction). Used by the designer to locate the instruction (line of third calling instruction).

A30808-X3247-K240-3-7619

207

Outputs OML:BSC
gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = =

Base Station Controller

Used by the designer to locate the instruction (file id of fourth calling instruction). Used by the designer to locate the instruction (line of fourth calling instruction). Not used. Not used. Not used. Not used. Not used. Not used. Not used.

Originator = 136 MOSSDFSUD A wrong message type has been received in some phase or the upload procedure from the BSC to the LMT/OMC.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction). Used by the designer to locate the instruction (line of second calling instruction). Used by the designer to locate the instruction (file id of third calling instruction). Used by the designer to locate the instruction (line of third calling instruction). Used by the designer to locate the instruction (file id of fourth calling instruction). Used by the designer to locate the instruction (line of fourth calling instruction). Not used. Not used. Not used. Not used. Not used. Not used. Not used.

Originator = 305 MOSICILEM A wrong message type has been sent by the IXLT software to its MPCC alarm interface task.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj = = = = = = = = = = Used by the designer to locate the checkpoint. IXLT copy that send bad message. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

208

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = = Not used. Not used. Not used. Not used. Not used.

kkkk llll mmmm nnnn oooo

Originator = 311 MOSICIOPO It is not possible to receive a pSOS+ message.


aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = 0x04 INVALID_PSOS_OUTPUT. Current value of the err variable. Current value of the mbx_id. Current value of the board number. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

Originator = 313 MOSICILPD A wrong type message has been received by BSC T-interface packet splitting task.
aaaa = Used by the designer as an internal error code; its value can be: - 0004 (duplicated job number); - 000D (wrong I/O destination value). Number of the source code line where error was issued. - Job number value of I/O header, if aaaa = 0004; - I/O destination value of I/O header, if aaaa = 000D. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

bbbb = cccc = dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm = = = = = = = = = =

A30808-X3247-K240-3-7619

209

Outputs OML:BSC
nnnn = oooo = Not used. Not used.

Base Station Controller

Originator = 314 MOSICILSH A wrong type message has been received by BSC Symbolic names handler task.
aaaa = bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = Used by the designer as an internal error code; its value is: 0001 (invalid operation code value of I/O header). Number of the source code line where error was issued. Operation code value of I/O header. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

Originator = 315 MOSICLFUP A wrong type message has been received by BSC Upload of proprietary log files task .
aaaa = Used by the designer as an internal error code; its value can be: - 0003 (invalid operation code value of I/O header); - 0004 (invalid file type requested for upload); - 0007 (invalid originator); - 000A (invalid log type). Number of the source code line where error was issued. - Io source value of I/O header, if aaaa = 0003 or 0004 or 0007; - Value of byte 1 of file subtype attribute, if aaaa = 000A. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

bbbb = cccc = dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = =

210

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Originator = 318 MOSICUSSC The Upload Server task received an unexpected message.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to lacate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to lacate the instruction (line of third calling instruction). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any). Number of process. Current state. Current event. Not used. Not used. Not used. Not used.

Originator = 500 MSDLSLTPI A wrong message was received by the IXLT loader task on MPCC processor: it may be a bad activation message or a wrong response from the IXLT FW.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction). Used by the designer to locate the instruction (line of second calling instruction). Used by the designer to locate the instruction (file id of third calling instruction). Used by the designer to locate the instruction (line of third calling instruction). Used by the designer to locate the instruction (file id of fourth calling instruction). Used by the designer to locate the instruction (line of fourth calling instruction). Used by the designer to indicate the signal type. Used by the designer to indicate the signal subtype. Used by the designer to indicate the source mailbox name. Used by the designer to indicate the source system. Not used. Not used. Not used.

Originator = 501 MSDLSLTPL, 503 MSDLSLTPT


A30808-X3247-K240-3-7619 211

Outputs OML:BSC

Base Station Controller

The Loading Server tasks received an unexpected message.


aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction). Used by the designer to locate the instruction (line of second calling instruction). Used by the designer to locate the instruction (file id of third calling instruction). Used by the designer to locate the instruction (line of third calling instruction). Used by the designer to locate the instruction (file id of fourth calling instruction). Used by the designer to locate the instruction (line of fourth calling instruction). Used by the designer to indicate the signal type. Used by the designer to indicate the signal subtype. Used by the designer to indicate the source mailbox name. Used by the designer to indicate the source system. Not used. Not used. Not used.

Originator = 502 MSDLSLTPP A wrong message was received by the PPXX loader task on MPCC processor: it may be a bad activation message or a wrong response from the PPXX loader task on TDPC.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction). Used by the designer to locate the instruction (line of second calling instruction). Used by the designer to locate the instruction (file id of third calling instruction). Used by the designer to locate the instruction (line of third calling instruction). Used by the designer to locate the instruction (file id of fourth calling instruction). Used by the designer to locate the instruction (line of fourth calling instruction). Used by the designer to indicate the signal type. Used by the designer to indicate the signal subtype. Used by the designer to indicate the source mailbox name. Used by the designer to indicate the source system. Not used. Not used. Not used.

Originator = 507 MSDBASDL An unexpected signal is received by BSCA or the signal is expected but it's occurred in a wrong time
aaaa = bbbb = Not used Not used

212

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = = = = = = = = = = Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used

cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

Originator = 510 MOSIWROMA, 513 MOSIWROSP A wrong source_sys value is occurred when a message is handled by Interworking task
aaaa = bbbb = cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = Source code line Used by the designer to indicate the Error description -INVALID_SUBSYSTEM Used by the designer to indicate the source_sys Used by the designer to indicate the dest_sys Used by the designer to indicate the flags Used by the designer to indicate the source_mbx Used by the designer to indicate the destination Used by the designer to indicate the signal_type Used by the designer to indicate the signal_subtype Used by the designer to indicate the datalen Used by the designer to indicate the operationcode Used by the designer to indicate the message_type Not used Not used Not used

Originator = 600 MSDBACTDA, 601 MSDBACTMT, 603 MSDBACTMA, 604 MSDBACTIA, 605 MSDBACTPA, 606 MSDBACTTA The processor controllers (MSDBACTDA--> PPLD controller, MSDBACTMA --> MPCC controller, MSDBACTIA --> IXLT controller, MSDBACTPA --> PPCC controller, MSDBACTTA --> TDPC controller) or the BSC Agent (MSDBACTMT) received an unexpected message.
aaaa bbbb cccc dddd eeee ffff = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction). Used by the designer to locate the instruction (line of second calling instruction). Used by the designer to locate the instruction (file id of third calling instruction). Used by the designer to locate the instruction (line of third calling instruction).

A30808-X3247-K240-3-7619

213

Outputs OML:BSC
gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = =

Base Station Controller

Used by the designer to locate the instruction (file id of fourth calling instruction). Used by the designer to locate the instruction (line of fourth calling instruction). Used by the designer to indicate the signal type. Used by the designer to indicate the signal subtype. Used by the designer to indicate the source mailbox name. Used by the designer to indicate the source system. Not used. Not used. Not used.

Originator = 700 TOSSDATPL A wrong message was received by the PPXX loader task on TDPC processor: it may be a bad message read in DUAM, a bad activation message, a message with bad subtype from MPCC task.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction). Used by the designer to locate the instruction (line of second calling instruction). Used by the designer to locate the instruction (file id of third calling instruction). Used by the designer to locate the instruction (line of third calling instruction). Used by the designer to locate the instruction (file id of fourthcalling instruction). Used by the designer to locate the instruction (line of fourthcalling instruction). Not used. Not used. Not used. Not used. Not used. Not used. Not used.

Originator = 2000 MDATABASE This error occurs when the Data Base task on MPCC processor receives a message containing some invalid parameters.
aaaa = bbbb = cccc = Source C line Source module identifier Depends on the source C line and the source module this field could be: 1) Not used 2) Used by the designer to indicate the source_sys of a message with a signal _type different from exepcted 3) Used by the designer to indicate a operation code wrong related to a message received Depends on the source C line and the source module this field could be: 1) Not used 2) Used by the designer to indicate the signal _type for a message received with an operation code wrong 3) Used by the designer to indicate the dest sys for a message with a signal type different

dddd =

214

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
from exepcted. Depends on the source C line and the source module this field could be: 1) Not used 2) Used by the designer to indicate the signal_subtype for a message received with an operation code wrong 3) Used by the designer to indicate the name of mailbox related to a message with signal_ type different from expected Depends on the source C line and the source module this field could be: 1) Not used 2) Used by the designer to indicate the source_sys for a message received with an operation code wrong 3) Used by the designer to indicate the destination related to a message with signal type different from expected Depends on the source C line and the source module this field could be: 1) Not used 2) Used by the designer to indicate the flags for a message received with an operation code wrong 3) Used by the designer to indicate the signal_type related to a message with signal type different from expected Depends on the source C line and the source module this field could be: 1) Not used 2) Used by the designer to indicate the name of mailbox related to a message received with an operation code wrong 3) Used by the designer to indicate the signal_subtype related to a message with signal type different from expected Depends on the source C line and the source module this field could be: 1) Not used 2) Used by the designer to indicate the element space[0] of mailbox related to a message received with an operation code wrong Depends on the source C line and the source module this field could be: 1) Not used 2) Used by the designer to indicate the element space[2] of mailbox related to a message received with an operation code wrong Depends on the source C line and the source module this field could be: 1) Not used 2) Used by the designer to indicate the element space[4] of mailbox related to a message received with an operation code wrong Not used Not used Not used Not used

eeee =

ffff =

gggg =

hhhh =

iiii =

jjjj =

kkkk =

llll mmmm nnnn oooo

= = = =

Originator = 2001 MDBCADHDE This error occurs when the Data Base task on MPCC processor receives a message containing some invalid parameters.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll = = = = = = = = = = = = Source code line. Source module identifier. Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used

A30808-X3247-K240-3-7619

215

Outputs OML:BSC
mmmm = nnnn = oooo = Not Used Not Used Not Used

Base Station Controller

Originator = 2100 CDBMDBFH This error occurs when the Data Base task on MPCC processor receives a message containing some invalid parameters.
aaaa = bbbb = Source code line. Depends on the source C line, this field could be: 1) Not used 2) Used by the designer to indicate the current state Depends on the source C line, this field could be: 1) Not used 2) Used by the designer to indicate the operaton code of IO_HDR message 3) Used by the designer to indicate the signal type of MSG_HDR message Depends on the source C line, this field could be: 1) Not used 2) Used by the designer to indicate the source of IO_HDR message 3) Used by the designer to indicate the signal sub_type of MSG_HDR message Depends on the source C line, this field could be: 1) Not used 2) Used by the designer to indicate the destination of IO_HDR message 3) Used by the designer to indicate the source of MSG_HDR message Depends on the source C line, this field could be: 1) Not used 2) Used by the designer to indicate the flags of MSG_HDR message Depends on the source C line, this field could be: 1) Not used 2) Used by the designer to indicate the name of mailbox related to MSG_HDR message Depends on the source C line, this field could be: 1) Not used 2) Used by the designer to indicate the element space[0] of mailbox Depends on the source C line, this field could be: 1) Not used 2) Used by the designer to indicate the element space[2] of mailbox Depends on the source C line, this field could be: 1) Not used 2) Used by the designer to indicate the element space[4] of mailbox Not Used Not Used Not Used Not Used Not Used

cccc =

dddd =

eeee =

ffff =

gggg =

hhhh =

iiii =

jjjj =

kkkk llll mmmm nnnn oooo

= = = = =

Originator = 2222 CDBMDHSA This error occurs when the Data Base task on MPCC processor receives a message
216 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

containing some invalid parameters. It's necessary to consider the case in which the message is received from a MPCC or TDPC processor, and the case related at an unknow processor origin.
aaaa = bbbb = Source C line where the alarm is issued Depends on the Source C line this field could be: 1) Used by the designer to indicate the source_sys of a message received from a processor different to MPCC and TDPC 2) Used by the designer to indicate the source C line where the task recognize the presencce of an error in a message recived (unexp_msg_orig) from MPCC or TDPC Depends on the source C line this field could be: 1) Used by the designer to indicate the signal type of a message recived from a processor different to MPCC and TDPC 2) Used by the designer to indicate the currennt state Depends on the source C line this field could be: 1) Used by the designer to indicate the signal subtype of a message received from a processor differten from MPCC and TDPC 2) Used by the designer to indicate the current instance object Depends on the source C line this field could be: 1) Used by the designer to indicate the flags of a message received from a processor different to MPCC and TDPC 2) Used by the designer to indicate the signal type of message recived from a MPCC or a TDPC processor Depends on the source C line this field could be: 1) Used by the designer to indicate the name of mailbox related to a message received from a processor different to MPCC and TDPC 2) Used by the designer to indicate the signal sub_type of message recived from a MPCC or a TDPC processor Depends on the source C line this field could be: 1) Used by the designer to indicate the element space[0] of mailbox related to a message received from a processor different to MPCC and TDPC 2) Used by the designer to indicate the flags of message recived from a MPCC or a TDPC processor Depends on the source C line this field could be: 1) Used by the designer to indicate the element space[2] of mailbox related to a message received from a processor different to MPCC and TDPC 2) Used by the designer to indicate the name of mailbox related to a message recived from a MPCC or a TDPC processor Depends on the source C line this field could be: 1) Used by the designer to indicate the element space[4] of mailbox related to a message received from a processor different to MPCC and TDPC 2) Used by the designer to indicate the element space[0] of mailbox related to a message recived from a MPCC or a TDPC processor Used by the designer to indicate the element space[2] of mailbox related to a message recived from a MPCC or a TDPC processor Used by the designer to indicate the element space[4] of mailbox related to a message recived from a MPCC or a TDPC processor Not used Not used Not used Not used

cccc =

dddd =

eeee =

ffff =

gggg =

hhhh =

iiii =

jjjj = kkkk = llll mmmm nnnn oooo = = = =

Originator = 2600 TDATABASE This error occurs when the Data Base task on TDPC processor receives a message containing some invalid parameters.
aaaa bbbb cccc dddd = = = = Source code line. Source module identifier. Not Used Not Used

A30808-X3247-K240-3-7619

217

Outputs OML:BSC
eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used

Base Station Controller

Originator = 3010 MSMAREPDE Error processor in the delay management has received an message that it cannot recognize.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Source code line of the error processor module. Signal subtype found in the received message. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

Originator = 3140 MSMSHPCCC This define is used to advice that a DISABLE request or LOCK FORCE request has been rejected by the device handler, and that Status Manager changes this response in SUCCESSFUL.A DISABLE request against a fault device, cannot be rejected.
aaaa bbbb cccc dddd eeee ffff gggg hhhh = = = = = = = = Source line Action Result Mnemonic Unit address[0] Unit address[1] Unit address[2] Unit address[3]

218

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = = = = Not used Not used Not used Not used Not used Not used Not used

iiii jjjj kkkk llll mmmm nnnn oooo

Originator = 3143 MSMSHPCPI This error indicates two possible situations: -DH has sent an UNSUCCESSFUL response to Status Manager during a CREATE response.In this case Status Manager complete the command but put the object in DISABLED state. -Status Manager has received a system response but the object isnt in transaction state.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Source line Action Result Mnemonic Unit address[0] Unit address[1] Unit address[2] Unit address[3] Not used Not used Not used Not used Not used Not used Not used

Originator = 4206 MDHNWDCDE An inconsistent message has been received by the device controller task of network, or an inconsistency internal to network device handler has been occurred induced by an expired timer.If the inconsistent message comes from Asub interface only the first field aaaa is significant.
aaaa = bbbb cccc dddd eeee = = = = source code line of the module MDHNWDCDE where error has been called or number of the TRAU that generated inconsistency. module where the error occurred (it could be MDHNWDCDE itself) source code line in the module <bbbb> where the error has been detected internal error code of for the error type (see SN64, PLLH,... PERMANENT_FAILURE) internal code for the alarmed NTW card (see SN64, PLLH,...PERMANENT_FAILURE; in this case should be always 0)

A30808-X3247-K240-3-7619

219

Outputs OML:BSC
ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = =

Base Station Controller

source system where the message is coming from (0: MPCC; 1: TDPC, 4: IXLT, 2: TRAU) signal type of the received message (meaningful for the designer) signal sub-type of the received message (meaningful for the designer) not used not used not used not used not used not used not used

Originator = 4209 MDHNWDCEP a)A status change is required for a not equipped Enva managed object or b)there is an inconsistence in the message coming from Status Manager.
aaaa = bbbb = source code line of the MDHNWDCEP module where error has been called (developer oriented). a)source system of the message received by the dispatcher engine managing enva objects (developer oriented) b) action required from Status Manager a)signal type of the of the message received by the dispatcher engine managing enva objects (developer oriented) b)mnemonic of the enva managed object. a)signal subtype of the message received by the dispatcher engine managing enva objects (developer oriented) b)instance of the object. a)Not used b)operational state of the object a)Not used b)administrative state of the managed object. Not used Not used Not used Not used Not used Not used Not used Not used Not used

cccc =

dddd =

eeee = ffff = gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = =

Originator = 4351 MDHBCDCDE An unknown or out of sequence message has been received by the BscController task.
aaaa = bbbb = cccc = local code error local data _LINE_

220

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = = = = = = = = = source mbx signal type signal subtype Not used Not used Not used Not used Not used Not used Not used Not used Not used

dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

Originator = 4400 MDHLCDCDE The LAPD handler task, from TDPC, is sending a message to LICD DH for a not equipped BTSM (case 1) or a generic message with wrong parameters is arrived to LICD DH (case 2).
aaaa = bbbb = cccc = dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = Developer reserved: code line number where error is emitted Developer reserved: type of error occurred Developer reserved: number of BTSM involved (case 1) or source processor involved (case 2) Developer reserved: (case 2 only): signal type Developer reserved: (case 2 only): signal subtype not used not used not used not used not used not used not used not used not used not used

Originator = 4403 MDHLCUTGE It has been notified to LICD DH the creation of radio channels on a BTSM that is not equipped
aaaa bbbb cccc dddd eeee = = = = = Developer oriented: source line of code where error is issued Developer oriented: internal error code Instance number of the BTSM Not used Not used

A30808-X3247-K240-3-7619

221

Outputs OML:BSC
ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used

Base Station Controller

Originator = 4501 MDHXXDCDE This warning message is issued when one of the following events takes place: a) an unexpected GbIC message comes to PPCU DH during a Get Info command b) a PPCU Get Info request comes from BSC Controller task to PPCU DH while another Get Info command (concerning another PPCU card) is still in progress. c) A Load PPCU Patch Request Nack message, different from Load Already In Progress, comes from Load Server task to PPCU Device Handler
aaaa = bbbb = case a: PPCU number; cases b and c: source line case a: number of periodic DH timer expirations (one or two) in GbIC - MPCC interface; case b: signal subtype inside Get Info message to PPCU DH case c: PPCU mnemonic case a: nackCause field (GbIC answer); case b: number of PPCU involved in unexpected command; case c: absolute card number (number of PPCU + 17) case a: cmd field; case b: PPCU number related to command correctly in progress case c: "Reason" of Nack inside Load Patch answer message (possible values: 13 = CSD_LD_ALREADY_IN_PROG, 14 = CSD_INVALID_SVR) case a: sequence number field; case b: number of timers expired for command correctly in progress case c: bit mask of PPCU cards involved in Patch Load case a: PCU mnemonic (object class field); case b: not used case c: "step" field of "Current Patch Load Command" variable (possible values: 1 = WAITING FOR LOAD SERVER ACK 2 = WAIT FOR FIRST KEEP ALIVE MESSAGE 3 = WAITING FOR SECOND KEEP ALIVE MESSAGE case a: PCU object identifier; case b: not used case c: Patch type (0 = ALL PATCH PERMANENT, 1 = ALL PATCH RUNNING, 2 = SINGLE_PATCH) cases a,b: not used case c: me mnemonic of patch object identifier cases a,b: not used case c: me address[0] of patch object identifier case a, b: not used case c: message signal subtype not used not used not used not used not used

cccc =

dddd =

eeee =

ffff =

gggg =

hhhh = iiii = jjjj = kkkk llll mmmm nnnn oooo = = = = =

222

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Originator = 4503 MDHXXDCSA This error is issued when an unexpected command answer arrives from PPCU Agent to PPCU Device Handler on MPCC.
aaaa = bbbb = cccc dddd eeee ffff = = = = Number of line where error collector is called. High byte: software module low byte: error code (unexpected response) Line where the problem took place PPCU card number Command (0x33 = GIVE STATUS; 0x34 = START; 0x32 = FORCE IN SERVICE) Result of command analysis (1 = OPERATING CODE INCONSISTENCY; 2 = COMMAND LENGTH INCONSISTENCY; 3 = SW STATE INCONSISTENCY; 4 = COMMAND RESULT INCONSISTENCY; 5 = COMMAND INCONSISTENCY; 6 = PCUC/ABIC/GBIC PROBLEM) Byte 0 of answer message Byte 1 of answer message Byte 2 of answer message Byte 3 of answer message Byte 4 of answer message Not used Not used Not used Not used

gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

= = = = = = = = =

Originator = 4600 MDHPRDCDE The signal subtype of the received message is not valid, it could be wrong or out of sequence.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Line in the code where the error has been issued. Code of the occurred error. Software module where the error took place. Line in the software module where the error has been discovered. Source system field in input message. Signal type field of the input message. Signal subtype field of the input message. Reserved [0,1] field of input message. Reserved [2,3] field of input message. Reserved [4,5] field of input message. Reserved [6,7] field of input message. Reserved [8,9] field of input message. Data field [0] of the received message. Data field [1] of the received message. Data field [2] of the received message.

A30808-X3247-K240-3-7619

223

Outputs OML:BSC

Base Station Controller

Originator = 4609 MDHPRDCHL, 4902 TDHPRDCHL The signal subtype of the message received by the Memory Align Server is not valid, it could be wrong or out of sequence.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Line in the code where the error has been issued. 1. Code of the occurred error. Software module where the error took place. Line in the software module where the error has been discovered. Source system field in input message. Signal type field of the input message. Signal subtype field of the input message. Reserved [0,1] field of input message. Reserved [2,3] field of input message. Reserved [4,5] field of input message. Reserved [6,7] field of input message. Reserved [8,9] field of input message. Not used. Not used.

Originator = 4609 MDHPRDCHL, 4902 TDHPRDCHL The standby FW answered with the wrong ACK to the message of cross copying the SW load.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Line in the code where the error has been issued. 2. The destination address of the SW load packet. The source address of the SW load packet. The length of the SW load packet. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

224

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Originator = 4702 TDHBFDCDE This error occurs when the BTSM DH receives a message containing some invalid parameters.
aaaa = bbbb = Line of module where the Error Collector call is. Internal error code (dh_gs.h): ERR_INVALID_RANGE = 0xEC72 ERR_UNEXISTING_ISTANCE = 0xEC6B ERR_UNEXPECTED_SUBTYPE = 0xEC68 ERR_DATA_INCONSITENCY = 0xEC70 ERR_UNEXPECTED_MEID = 0xEC71 ERR_UNEXPECTED_TIMEOUT = 0xEC76 ERR_UNEXPECTED_CLASS = 0xEC6a ERR_UNEXPECTED_SIGTYPE = 0xEC69 Module in which the error occurred. Line of the midule in which the error occurred. Source_sys Signal_type Signal_subtype reserved[0] reserved[2] reserved[4] reserved[8] body of message body of message body of message body of message

cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

= = = = = = = = = = = = =

Originator = 4751 TDHTRDCDE This error occurs when the TRAU DH receives a message containing some invalid parameters.
aaaa = bbbb = Line of module where the Error Collector call is. Internal error code (dh_gs.h): ERR_INVALID_RANGE = 0xEC72 ERR_UNEXISTING_ISTANCE = 0xEC6B ERR_UNEXPECTED_SUBTYPE = 0xEC68 ERR_DATA_INCONSITENCY = 0xEC70 ERR_UNEXPECTED_MEID = 0xEC71 ERR_UNEXPECTED_TIMEOUT = 0xEC76 ERR_UNEXPECTED_CLASS = 0xEC6a ERR_UNEXPECTED_SIGTYPE = 0xEC69 Module in which the error occurred. Line of the midule in which the error occurred. Source_sys Signal_type Signal_subtype Not used. Not used. Not used.

cccc dddd eeee ffff gggg hhhh iiii jjjj

= = = = = = = =

A30808-X3247-K240-3-7619

225

Outputs OML:BSC
kkkk llll mmmm nnnn oooo = = = = = Not used. Not used. Not used. Not used. Not used.

Base Station Controller

Originator = 4754 TDHTRDCMS This error indicates that there are no corrispondence between BSC alarm and TRAU alarm.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = the line number of the source module number of TRAU alarm number of BSC alarm mnemonic of the object (meid.mnem) object number ( meid.madd[0]) not used not used not used not used not used not used not used not used not used not used

Originator = 4901 TDHPRDCSV The signal subtype of the received message is not valid, it could be wrong or out of sequence.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Line in the code where the error has been issued. Code of the occurred error. Software module where the error took place. Line in the software module where the error has been discovered. Source system field in input message. Signal type field of the input message. Signal subtype field of the input message. Reserved [0,1] field of input message. Reserved [2,3] field of input message. Reserved [4,5] field of input message. Reserved [6,7] field of input message. Reserved [8,9] field of input message. Data field [0] of the received message. Data field [1] of the received message. Data field [2] of the received message.

226

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Originator = 4951 TDHGPDCDE The GPRS DH received an inconsistent message.


aaaa = bbbb = Source code line of the error processor module. Internal error code: 0x10 - GP_ERR_QUEUE_OVERFLOW 0x11 - GP_ERR_PCU_INIT 0x1F - GP_LAST_PCUALIGN_ERR 0x20 - GP_ERR_DATA_INCONSISTENCY 0x21 - GP_ERR_INVALID_RANGE 0x22 - GP_ERR_UNEXPECTED_SIGTYPE 0x23 - GP_ERR_UNEXISTING_INSTANCE 0x24 - GP_ERR_INVALID_MEID 0x25 - GP_ERR_INVALID_SM_ACTION 0x26 - GP_ERR_OBJ_NOT_EQUIPPED 0x27 - GP_ERR_GI_ALREADY_RUN 0x30 - GP_ERR_INVALID_GB_ACTION Source_sys found in the received message. Signal type found in the received message. Signal subtype found in the received message. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

= = = = = = = = = = = = =

Originator = 4960 UDHPCMNEN The GPRS DH received an inconsistent message.


aaaa bbbb cccc dddd eeee = = = = = Source code line of the error processor module. Source_sys found in the received message. Signal type found in the received message. Signal subtype found in the received message. command field in pcuHeader: 0x00 - PC_CREATE 0x01 - PC_DELETE 0x02 - PC_SET 0x03 - PC_GET_INFO 0x04 - PC_GET Sequence Number of the Command received (SN field in the pcuHeader) Object Class field in pcuHeader: 0x52 - MM_PCU 0x57 - MM_PTPPKF 0x79 - MM_PSCAN

ffff = gggg =

A30808-X3247-K240-3-7619

227

Outputs OML:BSC
hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = Object Id field in pcuHeader. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

Base Station Controller

Originator = 4980 NDHPDDCMA, 4990 YDHPDDCMA This error is issued when an inconsistent state is set inside state machine of PPXU/PPXL Agent.
aaaa = Source code line__LINE__, msg[0], msg[1], msg[2], CmdRspList[msg[0]], PPXUADescr.State First byte of MPCC message (command code) Second byte of MPCC message Third byte of MPCC message Command code inside Agent answer Card state inside Agent database Not used Not used Not used Not used Not used Not used Not used Not used Not used

bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

= = = = = = = = = = = = = =

Originator = 9000 MDGDMPIPR It will be issued if the message received from DH by the main task, after an End Diagnostic message, is different from the allowed one.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii = = = = = = = = = <source line> <signal_subtype> <mnemonic> not used not used not used not used not used not used

228

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = = = not used not used not used not used not used not used

jjjj kkkk llll mmmm nnnn oooo

Originator = 9000 MDGDMPIPR It will be issued if the message send by the main task to DH to activate or to end a diagnostic, has not been correctly exchanged.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = <source line> < DGWRONGMSG - 0x3> <signal_subtype> not used not used not used not used not used not used not used not used not used not used not used not used

Originator = 9000 MDGDMPIPR It will be issued if the message response from DH, after the request to activate a diagnostic, is different from the allowed one.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm = = = = = = = = = = = = = <source line> < mnemonic > not used not used not used not used not used not used not used not used not used not used not used

A30808-X3247-K240-3-7619

229

Outputs OML:BSC
nnnn = oooo = not used not used

Base Station Controller

Originator = 9000 MDGDMPIPR It will be issued if the message received by the main task from mailbox is different from the allowed one.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = <source line> < DGWRONGMSG - 0x3> < source system > < destination system > < signal_type > < signal_subtype > not used not used not used not used not used not used not used not used not used

Originator = 9001 MDGDMDAPR It will be issued if the message response from executor task, after the request to activate a diagnostic, is different from the allowed one.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = <source line> < signal_type > < instance > not used not used not used not used not used not used not used not used not used not used not used not used

230

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Originator = 9003 MDGDMPEPR , 9005 TDGDMPEPR It will be issued if the message received from executor task, after the request to activate or to stop a diagnostic, is different from the allowed one.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = <source line> < instance > < mot > not used not used not used not used not used not used not used not used not used not used not used not used

Originator = 10108 MQ3CB An unknown event occurred. The unknown event is discarded and the current operation is aborted
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = (developer oriented) source module (developer oriented) number of source module line (developer oriented) event code not used not used not used not used not used not used not used not used not used not used not used not used

##StartSpecProbl##
A30808-X3247-K240-3-7619 231

Outputs OML:BSC
Specific Problems = 047 RECEIVED CORRUPTED MESSAGE

Base Station Controller

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 511 MOSIWROCO, 512 MOSIWRORE,513 MOSIWROSP An invalid message layout is occurred when Interworking task is activated
aaaa = bbbb = Source code line Used by the designer to indicate the Error description -case 1: INVALID_MESSAGE_TYPE_IN_RESPONSE. Occurred when message_type field, in a response, is wrong -case 2: INVALID_ME_ID. Occurred when a message has an invalid MAINTENANCE_ENTIY_ID structure -INVALID_ATTRIBUTE. Occurred when a message contains an invalid attribute identifiers INVALID_OBJ. Occurred when a message contains invalid object class and/or instance values -case 3:COSIW_CORRUPTED_CMD_DATALEN(44). Occurred when a command contains an invalid datalen field. In this case NO NACK RESPONSE IS SENT -case 4:COSIW_CORRUPTED_RESP_DATALEN(45). Occurred when a response contains an invalid datalen field.In this case a NACK RESPONSE is sent to the requestor. -case 5:COSIW_CORRUPTED_SPONT_DATALEN(46).Occurred when a spontaneous contains an invalid datalen field Used by the designer to indicate the source_sys Used by the designer to indicate the dest_sys In cases 3-4-5 Used by the desiger to indicate Network element (BTS or TRAU) instance number. Used by the designer to indicate the flags Used by the designer to indicate the source_mbx Used by the designer to indicate the destination Used by the designer to indicate the signal_type Used by the designer to indicate the signal_subtype Used by the designer to indicate the datalen Used by the designer to indicate the operationcode Used by the designer to indicate the message_type Not used Not used Not used

cccc = dddd =

eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

= = = = = = = = = = =

232

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Originator = 510 MOSIWROMA, 512 MOSIWRORE A fossd_get_running_svr DBA function UNSUCCESSFUL result is occurred when Interworking task is running
aaaa = bbbb = Source code line Used by the designer to indicate the Error description -GET_NE_SVR. Occurred when is not possible to found software version value. Used by the designer to indicate the source_sys Used by the designer to indicate the dest_sys Used by the designer to indicate the flags Used by the designer to indicate the source_mbx Used by the designer to indicate the destination Used by the designer to indicate the signal_type Used by the designer to indicate the signal_subtype Used by the designer to indicate the datalen Used by the designer to indicate the operationcode Used by the designer to indicate the message_type Not used Not used Not used

cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

= = = = = = = = = = = = =

Originator = 700 TOSSDATPL During a PPXX loading, TIME OUT expired while loader task on TDPC was waiting for a packet to load.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to locate the instruction (line of third calling instruction, if any). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any). NOT USED. NOT USED. NOT USED. NOT USED. NOT USED. NOT USED. NOT USED.

A30808-X3247-K240-3-7619

233

Outputs OML:BSC

Base Station Controller

Originator = 3007 MSMAREPCO Error processor task on MPCC has received a message with unknown parameters.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = source code line of the module that generate the error not used. not used. not used. not used. not used. not used. not used. not used. not used. not used. not used. not used. not used. not used.

Originator = 3131 MSMSHPICE This error indicates that Status Manager has received a Disable request without status bits.The command is executed but Status Manager inform the operatore that the request is not correct.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Source line Source processor Source mailbox Action Mnemonic of target object Unit address[0] Unit address[1] Unit address[2] Unit address[3] Mnemonic under transaction Unit address[0] Unit address[1] Unit address[2] Unit address[3] Not used

Originator = 4306 MDH40MTPA Thi error occurs during validation of message for triggering periodic activities related to
234 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

dk40, if signal_type contained in the message is different from signal_type corresponding to TIME_OUT
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Module that generates the error Source code line of the module that generates the error Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

Originator = 5000 CPM_MPCC_ORIGINATOR Scanner device handler and writing files tasks have received an uncorrect message. All related additional info are developer oriented and useful for debugging activity.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Module that generates the error. Source code line of the module that generates the error. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use.

Originator = 5001 CPM_IMSI_ORIGINATOR This error is issued if there are problems after the receiving of a message All related additional info are developer oriented and useful for debugging activity .
A30808-X3247-K240-3-7619 235

Outputs OML:BSC
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Module that generates the error. Source code line of the module that generates the error. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use.

Base Station Controller

Originator = 5002 CPM_CTR_ORIGINATOR This error is issued if there are problems after the receiving of a message. All related additional info are developer oriented and useful for debugging activity
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Module that generates the error. Source code line of the module that generates the error. Internal use. Internal use Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use.

Originator = 5100 CPM_PCUC_ORIGINATOR This error is issued if there are problems after the receiving of a message. All related additional info are developer oriented and useful for debugging activity
aaaa = Module that generates the error.

236

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = = = = = = = = = = = Source code line of the module that generates the error. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use.

bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

Originator = 5500 CPM_TDPC_ORIGINATOR Performance measurements tasks on TDPC have received a message with unexpected parameters. All related additional info are developer oriented and useful for debugging activity
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Module that generates the error, it can be 1, 3 or 5. Source code line of the module that generates the error. Source code line of the module that generates the error. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use.

Originator = 7205 PKPMUTBUTM, 7207 PKPMDTBDTM Wrong RLC sequence is received from MS or wrong LLC length from SGSN.
aaaa bbbb cccc dddd eeee ffff = = = = = = Process State. Process Instance. EDOS Message Code. Process Source Line. Procedure Module Originator. Procedure Module Line.

A30808-X3247-K240-3-7619

237

Outputs OML:BSC
gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. PPCU/PPXU involved (1st byte) and Process Sending Message (2nd byte).

Base Station Controller

##StartSpecProbl##
Specific Problems = 084 AP MESSAGE LENGTH FAULT

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 7100 TL3RDALL A-Interface protocol error : the length of the message is wrong.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Process Identifier (see annex D for more details) Process Instance Process State Not Used Process Source Line Length Expected Message Length Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used

##StartSpecProbl##
Specific Problems = 085 AP MANDATORY ELEMENT FAULT

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

238

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Originator = 7100 TL3RDALL In the received message a mandatory Element Identifier is wrong.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Process Identifier (see annex D for more details) Process Instance Process State Not Used Process Source Line Received message Received message Received message Received message Received message Received message Received message Received message Received message Received message

##StartSpecProbl##
Specific Problems = 086 AP MANDATORY ELEMENT OVERFLOW

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 7100 TL3RDALL The received message contains an unexpected mandatory Element Identifier.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Process Identifier (see annex D for more details) Process Instance Process State Not Used Process Source Line Received message Received message Received message Received message Received message Received message Received message Received message Received message Received message

A30808-X3247-K240-3-7619

239

Outputs OML:BSC

Base Station Controller

##StartSpecProbl##
Specific Problems = 088 AP MESSAGE TYPE FAULT

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 7100 TL3RDALL The Message Type of the received message is wrong.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Process Identifier (see annex D for more details) Process Instance Process State Not Used Process Source Line Message Type Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used

##StartSpecProbl##
Specific Problems = 094 AP O&M DISCRIMINATOR FAULT

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 7100 TL3RDALL O&M-Interface protocol error : in the received message the Protocol Discriminator is wrong.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll = = = = = = = = = = = = Process Identifier (see annex D for more details) Process Instance Process State Not Used Process Source Line Protocol Discriminator Not Used Not Used Not Used Not Used Not Used Not Used

240

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
Not Used Not Used Not Used

mmmm = nnnn = oooo =

##StartSpecProbl##
Specific Problems = 095 AP OPTIONAL ELEMENT FAULT

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 7100 TL3RDALL In the received message an optional Element Identifier is wrong.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Process Identifier (see annex D for more details) Process Instance Process State Not Used Process Source Line Received message Received message Received message Received message Received message Received message Received message Received message Received message Received message

##StartSpecProbl##
Specific Problems = 096 AP OPTIONAL ELEMENT OVERFLOW

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 7100 TL3RDALL The received message contains an unexpected optional Element Identifier.
aaaa = bbbb = Process Identifier (see annex D for more details) Process Instance

A30808-X3247-K240-3-7619

241

Outputs OML:BSC
cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = Process State Not Used Process Source Line Received message Received message Received message Received message Received message Received message Received message Received message Received message Received message

Base Station Controller

##StartSpecProbl##
Specific Problems = 097 AP PROTOCOL DISCRIMINATOR FAULT

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 7100 TL3RDALL The Protocol Discriminator of the message received from A-bis Interface is wrong.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Process Identifier (see annex D for more details) Process Instance Process State Not Used Process Source Line Protocol Discriminator Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used

##StartSpecProbl##
Specific Problems = 177 INVALID ASUB MESSAGE

Event Type = COMMUNICATION FAILURE EVENT Severity = WARNING


242 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Proposed Repair Actions = 1 NO ACTION

Originator = 4751 TDHTRDCDE This error occurs when the device handler of the TRAUs receives an invalid message from the Asub Interface.
aaaa = bbbb = Line of the module where the Error Collector call is Internal error code (dh_gs.h): ERR_UNEXPECTED_CLASS = 0xEC6A ERR_UNEXISTING_ISTANCE = 0xEC6B ERR_UNEXPECTED_SIGTYPE = 0xEC69 ERR_UNEXPECTED_SUBTYPE = 0xEC68 ERR_UNEXPECTED_MEID = 0xEC71 ERR_INVALID_RANGE = 0xEC72 ERR_DATA_INCONSISTENCY = 0xEC70 ERR_UNEXPECTED_TIMEOUT = 0xEC76 ERR_INVALID_SM_ACTION = 0xEC75 ERR_UNEXPECTED_INFO_ID = 0xEC66 ERR_UNEXPECTED_TYPE = 0xEC67 Module in which the error occurred Line of the module in which the error occurred Message Type Object Class Object Instance [0] Object Instance [1] Object Instance [2] not used not used not used not used not used not used

cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

= = = = = = = = = = = = =

##StartSpecProbl##
Specific Problems = 181 INVALID ABIS MESSAGE

Event Type = COMMUNICATION FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 4702 TDHBFDCDE This error occurs when the BTSM device handler receives an invalid message from Abis interface.
aaaa = bbbb = Line of the module where the Error Collector call is. Internal error code (dh_gs.h): ERR_INVALID_RANGE = 0xEC72 ERR_UNEXISTING_ISTANCE = 0xEC6B ERR_UNEXPECTED_SUBTYPE = 0xEC68 ERR_DATA_INCONSITENCY = 0xEC70 ERR_UNEXPECTED_MEID = 0xEC71

A30808-X3247-K240-3-7619

243

Outputs OML:BSC
ERR_UNEXPECTED_TIMEOUT = 0xEC76 ERR_UNEXPECTED_CLASS = 0xEC6a ERR_UNEXPECTED_SIGTYPE = 0xEC69 Module in which the error occurred. Line of the module in which the error occurred. Message Type. Object Class. Object Instance[0]. Object Instance[1]. Object Instance[2]. not used not used not used not used not used not used

Base Station Controller

cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

= = = = = = = = = = = = =

##StartSpecProbl##
Specific Problems = 245 AP TRACE ERROR NOTIFICATION INVALID PARAMETER

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 7100 TL3RDALL A not correct MSG_INVOKE_TRACE message was received by the BSC.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Process Identifier (see annex D for more details) Process Instance Process State Not Used Process Source Line Trace Error Cause Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used

244

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

##StartSpecProbl##
Specific Problems = 262 INVALID MESSAGE TO PCUC

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 813 TOSICIOOT It is not possible to write a message on DUAM, because the filed dest_sys of the RTE+ message is wrong: it is not possible to write a message on PCUC-TDPC or PPXU-TDPC duam.
aaaa = 0x09 INVALID_DESTINATION_SYSTEM 0x0a INVALID_DUAM_NUMBER 0x28 INVALID_LOGICAL_ASSOCIACTION Current value of the variable source_sys Current value of the variable dest_sys Current value of the variable source_mbx Current value of the variable dest_mbx Current value of the variable signal_type Current value of the variable signal_subtype Current value of the variable object_name Current value of the variable object_number Current value of the variable pcu_number 0x01 REGULAR_CAPACITY_CONF 0X02 HIGH_CAPACITY_CONF not used not used not used not used

bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

= = = = = = = = = = = = = =

##StartSpecProbl##
Specific Problems = 305 ABIC INVALID MESSAGE

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 7203 PKINABMABD Wrong message is received from AbIC for a specific PDT
aaaa bbbb cccc dddd eeee ffff = = = = = = Process state Process instance EDOS message code Process line originator Not used. Relative TRX of the BVCI where the Invalid message was received (1st byte) and error cause (2nd byte): 0x01: CRC Error: a message from BTS with CRC error has been detected by AbIC. When the PCu receives three even no consecutive CRC indications on the same PDT, without having at least two conecutive correct frames in between, the PDT alignment is considered lost and the corresponding channel is released.

A30808-X3247-K240-3-7619

245

Outputs OML:BSC
0x02: 0x03: 0x04: 0x05: 0x07:

Base Station Controller

0x08:

0x09:

0x0a:

Invalid Payload type received: a message with wrong Payload Type has been received; Message not expected received: the MS has sent a message in a wrong block; Wrong Op code from AbIC; AbIC has sent two messages with not in sequence Block Number: the PDT is released. A message indicating Time Alignment Error is received: the content is considered as invalid and any expected RLC block is considered as not arrived. This error message is issued whenever the BTS indicates to the PCU the reception of a wrong downlink frame. When the PCU receives for the same PDT three uncorrect frames, even not consecutive, without having at least two consecutive correct frames in between, the PDT alignment is considered lost and the corresponding channel is released. Valid for PPXU only: during Alignment phase or at the end of the alignment it reports one these possible inconsistencies : - Unexpected Frame type - Unknown frame type - Corrupted frame - Invalid Time Alignment Adjustment Request; It doesn't cause any PDT release; Valid for PPXU only and used as warning: either a block received by the AbIC through the HDLC controller was corrupted or no blocks were received. The persistence of this problem is signalled through the Alarm Status Report and is checked by a maintenance function Wrong filling of "expected structure"

gggg hhhh iiii jjjj kkkk llll

= = = = = =

mmmm = nnnn = oooo =

For causes 0x02, 0x03, 0x04 and 0x0a the message is discarded , for cause 0x05 the channel is released, for causes 0x01 and 0x07 the channel is released if the problem is occurring in groups of three uncorrect frames, even not consecutive, without having at least two consecutive correct frames in between, for cause 0x08 no action is done but the emission of the error, for cause 0x09 eventual actions are done in Maintenance Area. Opcode of AbIC primitive (only for internal use). First byte of RLC message contained in AbIC primitive (it includes the RLC Payload type) Second byte of RLC message contained in AbIC primitive Third byte of RLC message contained in AbIC primitive BVCI TS number where the invalid message was received (1st byte) and UL Block Number of the invalid message Error information (1st 4 bits, only on PPXU) and UL Super Block Number of the invalid message (last 10 bits) PDT number where the invalid message was received PPCU/PPXU involved (1st byte) and Process sending message (2nd byte).

246

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

43 MESSAGE NOT INITIALIZED


FAILURE EVENT REPORT: NAME = Probable cause = Specific Problems = Event Type = Event Time = Severity = Trend Indication = Notification Identifier = Correlated Notification Identifier = Related MO = Proposed Repair Actions = Additional Text = Originator = Additional Words =
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo <R.T.D.>

<R.T.D.> <R.T.D.> Message Not Initialized <see legend> <see legend> <R.T.D.> <see legend> <R.T.D.> <R.T.D.> <displayed only during Alarm Alignment> <R.T.D.> <R.T.D.> <see legend> <R.T.D.> <see legend>

Software Version =

Legend:

Specific Problems = 026 MESSAGE NOT INITIALIZED WARNING

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 7012 TL3N7UTIH1, 7017 TL3N7DIMU1, 7018 TL3N7DIST1, 7053 TL3N7TMFC1, 7054 TL3N7GESG1, 7056 TL3N7GESG3, 7057 TL3N7GESG4, 7058 TL3N7GESG5 This error is output when an internal message received contains wrong parameters.
aaaa bbbb cccc dddd = = = = Instance EDOS Signal Source C line where the error is occurred Error type. It can assume the following values (and as consequence the other words make sense): 1 MTP INVALID IMU RECEIVED eeee = IMU ffff oooo = not used 2 MTP INVALID SLOT OR PCM LINE eeee = State ffff = Action gggg = PCM line hhhh = Time slot iiii oooo = not used

A30808-X3247-K240-3-7619

247

Outputs OML:BSC
3 MTP INVALID ACTION FROM SM eeee = State ffff = Action gggg oooo = not used 4 MTP INVALID SIGNAL SUBTYPE 5 MTP INVALID SIGNAL TYPE eeee = SIGNAL TYPE ffff = SIGNAL SUBTYPE gggg oooo = not used 6 MTP INVALID LINK NUMBER eeee = Link number ffff oooo = not used 7 MTP INVALID ACTIVATION TYPE eeee = activation type ffff oooo = not used 8 MTP INVALID MNEMONIC NAME eeee = Action ffff = Mnemonic gggg oooo = not used 9 MTP INVALID AUDIT MSG eeee = AUDIT MESSAGE TYPE ffff oooo = not used 10 WRONG PRIMTYPE 11 WRONG PRIMID 12 WRONG SPCD 13 WRONG SSND 14 WRONG SPCG 15 WRONG SSNG eeee oooo = not used see dddd Additional Info see dddd Additional Info see dddd Additional Info see dddd Additional Info see dddd Additional Info see dddd Additional Info see dddd Additional Info see dddd Additional Info see dddd Additional Info see dddd Additional Info see dddd Additional Info

Base Station Controller

eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

= = = = = = = = = = =

248

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

44 MESSAGE OUT OF SEQUENCE


FAILURE EVENT REPORT: NAME = Probable cause = Specific Problems = Event Type = Event Time = Severity = Trend Indication = Notification Identifier = Correlated Notification Identifier = Related MO = Proposed Repair Actions = Additional Text = Originator = Additional Words =
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo <R.T.D.>

<R.T.D.> <R.T.D.> Message Out Of Sequence <see legend> <see legend> <R.T.D.> <see legend> <R.T.D.> <R.T.D.> <displayed only during Alarm Alignment> <R.T.D.> <R.T.D.> <see legend> <R.T.D.> <see legend>

Software Version =

Legend:

Specific Problems = 032 MESSAGE OUT OF SEQUENCE WARNING

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 124 MOSSDNDDL0 A message received by the BTSE download task is out of sequence.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll = = = = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to locate the instruction (line of third calling instruction, if any). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any). Message source system. Signal type. Signal subtype. ABIS, ASUB, LMT or OMC operation code.

A30808-X3247-K240-3-7619

249

Outputs OML:BSC
mmmm = nnnn = oooo = NE identifier. not used not used

Base Station Controller

Originator = 125 MOSSDNDDL1 A message received by the TRAU download tasks is out of sequence.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to locate the instruction (line of third calling instruction, if any). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any). Message source system. Signal type. Signal subtype. ABIS, ASUB, LMT or OMC operation code. NE identifier. not used not used

Originator = 126 MOSSDNSBL A message received by the BTSE alignment task is out of sequence.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to locate the instruction (line of third calling instruction, if any). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any). Message source system. Signal type. Signal subtype. ABIS, ASUB, LMT or OMC operation code. NE identifier. not used not used

250

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Originator = 127 MOSSDNSTL A message received by the TRAU alignment tasks is out of sequence.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to locate the instruction (line of third calling instruction, if any). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any). Message source system. Signal type. Signal subtype. ABIS, ASUB, LMT or OMC operation code. NE identifier. not used not used

Originator = 133 MOSSDFSDS During a download from the LMT/OMC to the BSC, the download task was waiting for messages carrying segments of the file, but the segments received were in the wrong order.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to locate the instruction (line of third calling instruction, if any). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any). not used not used not used not used not used not used not used

A30808-X3247-K240-3-7619

251

Outputs OML:BSC

Base Station Controller

Originator = 313 MOSICILPD A message received by BSC T-interface packet splitting task is out of sequence.
aaaa = Used by the designer as an internal error code; its value can be: - 0005 (wrong packet size); - 0006 (wrong packet number); - 0007 (wrong packet type); - 0008 (wrong job number); - 000B (unexpected timeout received). Number of the source code line where error was issued. - Job number value of I/O header, if aaaa = 0005 or 0006 or 0007 or 0008; - Signal subtype value of RTE header, if aaaa = 000B. - Expected max size, if aaaa = 0005; - Expected packet number, if aaaa = 0006; - Received packet type, if aaaa = 0007. - Actual size, if aaaa = 0005; - Actual packet number, if aaaa = 0006. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

bbbb = cccc = dddd =

eeee = ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = =

Originator = 315 MOSICLFUP A message received by the BSC Upload of proprietary log files task is out of sequence.
aaaa = Used by the designer as an internal error code; its value can be: - 0005 (upload already in progress); - 0006 (upload not in progress); - 000C (invalid transfer id). Number of the source code line where error was issued. Transfer identifier (most significant word). Transfer identifier (least significant word). Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

= = = = = = = = = = = = = =

252

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Originator = 318 MOSICUSSC The Upload Server received an out of sequence Load Data Segment.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to lacate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to lacate the instruction (line of third calling instruction). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any). Number of process. Current state. Current event. Expected segment. Received segment. Not used. Not used.

Originator = 502 MSDLSLTPP The PPXX loader task received an out of sequence Load Data Segment.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to lacate the instruction (file id of first calling instruction). Used by the designer to lacate the instruction (line of first calling instruction). Used by the designer to lacate the instruction (file id of secondcalling instruction). Used by the designer to lacate the instruction (line of secondcalling instruction). Used by the designer to lacate the instruction (file id of third calling instruction). Used by the designer to lacate the instruction (line of third calling instruction). Used by the designer to lacate the instruction (file id of fourth calling instruction). Used by the designer to lacate the instruction (line of fourth calling instruction). Not used. Not used. Not used. Not used. Not used. Not used. Not used.

Originator = 513 MOSIWROSP Operating System Interworking task receives Start or End Alignment spontaneous with
A30808-X3247-K240-3-7619 253

Outputs OML:BSC

Base Station Controller

correlated notification mismatch values


aaaa = bbbb = cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = Source code line Used by the designer to indicate the Error description -COSIW_OUT_OF_SEQUENCE Used by the designer to indicate the source_sys Used by the designer to indicate Network element instance number Used by the designer to indicate dest_sys Used by the designer to indicate the flag Used by the designer to indicate the source_mbx Used by the designer to indicate the destination_mbx Used by the designer to indicate the signal_type Used by the designer to indicate the signal_subtype Used by the designer to indicate the datalen Used by the designer to indicate the operationcode Used by the designer to indicate the message_type Not used Not used

Originator = 700 TOSSDATPL During a PPXX loading, the PPXX loader task on TDPC received a packet out of sequence from the PPXX loader task on MPCC.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to locate the instruction (line of third calling instruction, if any). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any). not used not used not used not used not used not used not used

Originator = 4500 MDHXXDCCH This error message is issued when a PPLD or PPCC or PPCU Load command is sent by BSC Agent task to PPxx Device Handler and one PPLD or PPCC or PPCU is not in required Offline status, that is the card was not previously reserved by BSC Agent for the operation. This warning is generated only if the command was not requested for all PPCC or PPLD or PPCU.
254 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = = = = = = = = = = = = Source file internal identifier Line number in source code Error code (Card Not Stopped) Number of physical PPLD or PPCC or PPCU Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used

aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

Originator = 4501 MDHXXDCDE This error is issued when an unexpected message has arrived from GPRS DH to PPCU DH.
aaaa = bbbb = cccc = PCU number Counter of retries. Old state of the finite state machine (Possible values: 0 = PCUSTS_RUNNING, 1 = PCUSTS_W_TRANS_CARDOFF_ACK, 2 = PCUSTS_W_PERM_CARDOFF_ACK, 3 = PCUSTS_W_CARDON_ACK, 4 = PCUSTS_OUTAGE) New state of the finite state machine. Event induced by GPRS DH message (possible values: 0 = PCUEVT_RESTART, 1 = PCUEVT_TCARD_OFF_ACK, 2 = PCUEVT_PCARD_OFF_ACK, 3 = PCUEVT_CARD_ON_ACK, 4 = PCUEVT_CARD_SWITCH, 5 = PCUEVT_CRASH, 6 = PCUEVT_OUTAGE_END, 7 = PCUEVT_TM_EXPIRED, 8 = PCUEVT_NULL) Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used

dddd = eeee =

ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

= = = = = = = = = =

A30808-X3247-K240-3-7619

255

Outputs OML:BSC

Base Station Controller

Originator =

4503 MDHXXDCSA 4514 MDHXXLUSA

This error is issued when an unexpected message has arrived from GPRS DH to PPXU/PPXL DH.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Error parameter Line Number of card involved not used not used not used not used not used not used not used not used not used not used not used not used

Originator = 4512 MDHXXLUDE This error is issued when an unexpected message has arrived from GPRS DH to PPXU/PPXL DH.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Number of PCU Number of retry Old state of the finite state machine New state of the finite state machine Event induced by GPRS DH message Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used

256

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Originator = 4980 NDHPDDCMA This error is issued when, during PPXU Agent procedure for answer to MPCC, an internal semaphore is found not locked.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Source code line. Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used

Originator = 5000 CPM_MPCC_ORIGINATOR This error message is issued when the scanner device handler receives an unexpected message. All related additional info are developer oriented and useful for debugging activity
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Module that generates the error. Source code line of the module that generates the error. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use.

Originator = 5500 CPM_TDPC_ORIGINATOR

A30808-X3247-K240-3-7619

257

Outputs OML:BSC

Base Station Controller

This error message is issued when there is a synchronization loss between TDPC and MPCC. All related additional info are developer oriented and useful for debugging activity
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Source module that generates the error Source code line of the module that generates the error. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use.

Originator = 7000 TL3N7SCOC050, 7001 TL3N7SCOC060, 7002 TL3N7SCLC010, 7003 TL3N7SCOC040, 7004 TL3N7SCOC030, 7005 TL3N7SCOC020, 7006 TL3N7SCOC010, 7007 TL3N7SCRC010, 7008 TL3N7SCPI030, 7009 TL3N7SCPI020, 7010 TL3N7SCPI010, 7011 TL3N7LTST1, 7013 TL3N7LMAC2, 7014 TL3N7LTST2, 7015 TL3N7HMDD1, 7016 TL3N7LTST3, 7017 TL3N7DIMU1, 7018 TL3N7DIST1, 7019 TL3N7UTEH1, 7020 TL3N7UTOH1, 7021 TL3N7HMRT1, 7022 TL3N7LMAC3, 7023 TL3N7LMAC4, 7024 TL3N7LMAC5, 7025 TL3N7LMAC1, 7026 TL3N7TMLA1, 7027 TL3N7TMLA2, 7028 TL3N7TMSR1, 7029 TL3N7TMSR2, 7030 TL3N7TMSR3, 7031 TL3N7TMCB1, 7032 TL3N7TMCB2, 7033 TL3N7TMCB3, 7034 TL3N7TMCB4, 7035 TL3N7TMCB5, 7036 TL3N7TMCO1, 7037 TL3M7TMCO2, 7038 TL3N7TMCO3, 7039 TL3N7TMCO4, 7040 TL3N7TMCO5, 7041 TL3N7TMCO6, 7042 TL3N7TMCO7, 7043 TL3N7TMCO8, 7044 TL3N7UTOS1, 7045 TL3N7SCMG010, 7046 TL3N7UTER1, 7047 TL3N7GEMG1, 7048 TL3N7GEMG2, 7049 TL3N7GEMG3, 7050 TL3N7GEMR1, 7051 TL3N7GEGS1, 7054 TL3N7GESG1, 7055 TL3N7GESG2, 7056 TL3N7GESG3, 7057 TL3N7GESG4, 7058 TL3N7GESG5 Reception of an unexpected message in one process state of the network layer 7 functional area.
aaaa = bbbb = cccc = dddd = eeee = Instance EDOS Signal (see annex D for more details). For the MTP processes (SCO, SPI, SCL, SRC, SMG) the correct value is done by the expression 'EDOS signal - 0xAA' Source C Line where the error is occurred Process state Error type. It can assume the following values: 0 = MESSAGE OUT OF SEQUENCE 1 = TIMER EXPIRED not used not used not used not used not used not used not used

ffff gggg hhhh iiii jjjj kkkk llll

= = = = = = =

258

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
not used not used not used

mmmm = nnnn = oooo =

Originator = 7053 TL3N7TMFC1 This report means that a congestion IMU for an unavailable SS7 link is arrived.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Instance EDOS Signal (see annex D for more details) Source C line where the error is occurred 1 - TIMER EXPIRED not used not used not used not used not used not used not used not used not used not used not used

Originator = 7100 TL3RDALL Reception of an unexpected message in one level 3 radio process state.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = not used not used not used not used Originator (see annex D for more details) Destination (see annex D for more details) Code message (see annex D for more details) Instance Process state not used not used not used not used not used not used

A30808-X3247-K240-3-7619

259

Outputs OML:BSC

Base Station Controller

Originator = 7200 PKINRMMRMD, 7201 PKINOMMGMD, 7202 PKINGBMGBD, 7203 PKINABMABD, 7204 PKPMUTBUTC, 7205 PKPMUTBUTM, 7206 PKPMDTBDTC, 7207 PKPMDTBDTM, 7208 PKTSPRMPCH, 7209 PKTSPRMPPM, 7210 PKTSPRMPFR, 7211 PKTSABBPDS, 7212 PKTSABBTBS, 7213 PKUTBMBUPR, 7214 PKUTBMBBVM, 7215 PKUTBMBGPG, 7216 PKUTBMBLLM, 7217 PKUTBMBLLR, 7218 PKUTBMBGOV, 7219 PKUTGEMGER, 7220 PKUTTGBTGM, 7221 PKUTTGBTBM, 7222 PKGBICOH, 7223 PKGBICSIGIH, 7224 PKGBICDATIH, 7225 PKTDPCRMIH, 7226 PKTDPCOMIH, 7227 PKTDPCOH, 7228 PKABICIH. Reception of an unexpected message in one UPK process state.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Process State. Process Instance. EDOS Message Code. Process Source Line. Procedure Module Originator. Procedure Module Line. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. PPCU/PPXU involved (1st byte) and Process Sending Message. (2nd byte).

Originator = 8000 MNCPCMHIP This error message is issued when Network Controller receives a message from LV3 Radio with an unexpected sequence number. The probable cause could be the loss of some messages, or the time inversion of 2 messages for I/O problems. The other info field reports the message layout and the expected message number.
aaaa = bbbb = cccc = Source line code where error was issued message discriminator (it should be 3) message type: 0XB4 = New call setup or hand over 0XB0 = Call release message counter value for call processing software no. of PCMA no. of TSLA no. of TRX mask containing information for the radio channel number request cause (meaningful only if cccc = 0XB4): 1= New call assignment 2= Hand over external to BSC 3= Hand over internal to BSC (inter/intra-cell)

dddd eeee ffff gggg hhhh iiii

= = = = = =

260

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = = = message counter value for Network controller not used not used not used not used not used

jjjj kkkk llll mmmm nnnn oooo

Originator = 10108 MQ3CB A wrong job number or sequences number has been detected
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = (developer oriented) source module (developer oriented) number of source module line (developer oriented) message length (developer oriented) job number or the sequence number not used not used not used not used not used not used not used not used not used not used not used

A30808-X3247-K240-3-7619

261

Outputs OML:BSC

Base Station Controller

45 SYSTEM CALL UNSUCCESSFUL


FAILURE EVENT REPORT: NAME = Probable cause = Specific Problems = Event Type = Event Time = Severity = Trend Indication = Notification Identifier = Correlated Notification Identifier = Related MO = Proposed Repair Actions = Additional Text = Originator = Additional Words =
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo <R.T.D.>

<R.T.D.> <R.T.D.> System Call Unsuccessful <see legend> <see legend> <R.T.D.> <see legend> <R.T.D.> <R.T.D.> <displayed only during Alarm Alignment> <R.T.D.> <R.T.D.> <see legend> <R.T.D.> <see legend>

Software Version =

Legend:

##StartSpecProbl##
Specific Problems = 002 DATABASE BACKUP FAILED

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 2000 MDATABASE The error occurs if is not possible to active the saving task or if the disk saving procedure fails. Note: For the corrispondence between the displayed numbers and the file identifiers, see ANNEX C..
aaaa bbbb cccc dddd eeee ffff gggg hhhh = = = = = = = = line. file identifier. Not used. Not used. Not used. Not used. Not used. Not used.

262

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = = = = Not used. Not used. Not used. Not used. Not used. Not used. Not used

iiii jjjj kkkk llll mmmm nnnn oooo

##StartSpecProbl##
Specific Problems = 003 FUNCTION CALL UNSUCCESSFUL

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 124 MOSSDNDDL0 A function call has failed in some phase of a BTSE download procedure from BSC.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to locate the instruction (line of third calling instruction, if any). Used by the designer to locate the instruction (file id of fourth calling instruction, if any) Used by the designer to locate the instruction (line of fourth calling instruction, if any) Not used. Not used. Not used. Not used. Not used. Not used. Not used.

Originator = 125 MOSSDNDDL1 A function call has failed in some phase of a TRAU download procedure from BSC.
aaaa bbbb cccc dddd = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any).

A30808-X3247-K240-3-7619

263

Outputs OML:BSC
eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = =

Base Station Controller

Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to locate the instruction (line of third calling instruction, if any). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any). Not used Not used Not used Not used Not used Not used Not used

Originator = 507 MSDBASDL A function call by BSC Agent task has failed.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to rebuild the call stack. Used by the designer to rebuild the call stack. Used by the designer to rebuild the call stack. Used by the designer to rebuild the call stack. Used by the designer to rebuild the call stack. Used by the designer to rebuild the call stack. Used by the designer to rebuild the call stack. Used by the designer to rebuild the call stack. Used by the designer to rebuild the call stack. Used by the designer to rebuild the call stack. Used by the designer to rebuild the call stack. Used by the designer to rebuild the call stack. Used by the designer to rebuild the call stack. Used by the designer to rebuild the call stack. Used by the designer to rebuild the call stack.

Originator = 10100 MQ3US An internal Q3 stack procedure has failed.


aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj = = = = = = = = = = source file identifier. line number within the source module. not used. not used. not used. not used. not used. not used. (developer oriented) it identifies a failed internal action. not used.

264

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = = not used. not used. not used. not used. not used.

kkkk llll mmmm nnnn oooo

Originator = 10108 MQ3CB Temporary anomaly to the communication between CBC and Q3 stack
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = (developer oriented) Source module (developer oriented) Number of source module line. (developer oriented) Error code not used. not used. not used. not used. not used. not used. not used. not used. not used. not used. not used. not used.

##StartSpecProbl##
Specific Problems = 029 SYSTEM CALL UNSUCCESSFUL WARNING

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 5 MOSFSIODF A system call has failed in some phase of a Delete File procedure from BSC.
aaaa bbbb cccc dddd eeee ffff gggg hhhh = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to locate the instruction (line of third calling instruction, if any). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any).

A30808-X3247-K240-3-7619

265

Outputs OML:BSC
iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = Not used. Not used. Not used. Not used. Not used. Not used. Not used.

Base Station Controller

Originator = 6 MOSFSIODD During the display directory command it was not possible to activate an operating system service (message reception/sending, memory allocation), though it repeatedly tried to do it.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to locate the instruction (line of third calling instruction, if any). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any). Not used. Not used. Not used. Not used. Not used. Not used. Not used.

Originator = 122 MOSSDCFFS A system call has failed in some phase of a Set/Create BTSM/TRAU command specifying the Expected SW Version attribute
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll = = = = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to locate the instruction (line of third calling instruction, if any). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any). Not used. Not used. Not used. Not used.

266

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
Not used. Not used. Not used.

mmmm = nnnn = oooo =

Originator = 124 MOSSDNDDL0 A system call has failed in some phase of a BTSE download procedure from BSC.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to locate the instruction (line of third calling instruction, if any). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any). Not used. Not used. Not used. Not used. Not used. Not used. Not used.

Originator = 125 MOSSDNDDL1 A system call has failed in some phase of a TRAU download procedure from BSC.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to locate the instruction (line of third calling instruction, if any). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any). Not used. Not used. Not used. Not used. Not used. Not used. Not used.

A30808-X3247-K240-3-7619

267

Outputs OML:BSC

Base Station Controller

Originator = 126 MOSSDNSBL A system call has failed in some phase of a BTSE alignment procedure from BSC.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to locate the instruction (line of third calling instruction, if any). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any). Not used. Not used. Not used. Not used. Not used. Not used. Not used.

Originator = 127 MOSSDNSTL A system call has failed in some phase of a TRAU alignment procedure from BSC.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = A system call has failed in some phase of a TRAU alignment procedure from BSC. Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to locate the instruction (line of third calling instruction, if any). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any). Not used. Not used. Not used. Not used. Not used. Not used. Not used.

Originator = 128 MOSSDNSBC, 129 MOSSDNSTC


268 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

A system call has failed during the execution of a BTSE/TRAU SW Activation command.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to locate the instruction (line of third calling instruction, if any). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any). Not used. Not used. Not used. Not used. Not used. Not used. Not used.

Originator = 130 MOSSDFSMS, 132 MOSSDFSCS During a copy or move sw command it was not possible to activate an operating system service (message reception/sending, memory allocation), though the software repeatedly tried to do it.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to locate the instruction (line of third calling instruction, if any). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any). Not used. Not used. Not used. Not used. Not used. Not used. Not used.

Originator = 131 MOSSDFSRS A system call failed in some phase of a Get SW Version procedure from BSC.
aaaa = bbbb = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction).

A30808-X3247-K240-3-7619

269

Outputs OML:BSC
cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = =

Base Station Controller

Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to locate the instruction (line of third calling instruction, if any). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any). Not used. Not used. Not used. Not used. Not used. Not used. Not used.

Originator = 133 MOSSDFSDS During a download from the LMT/OMC to the BSC, the download task could not activate an operating system service (message reception/sending, memory allocation), though it repeatedly tried to do it.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to locate the instruction (line of third calling instruction, if any). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any). Not used. Not used. Not used. Not used. Not used. Not used. Not used.

Originator = 301 MOSICCPRT, 815 TOSICCPRT This error occurs due to an internal error within the inter-processor links receive task.
aaaa = Internal error type:

270

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
0001 Unable to get a memory block for received message. 0002 Unable to write the received message into application software mailbox. 0003 Error detected in IPC header of received message. 0004 Error detected in RTE header of received message. 0005 Invalid length of revieved message (from software on other copy). 0006 Invalid length of received message (from firmware on other copy). 0007 Error detected in received messagess firmware header. 0008 Error converting the firmware header. 0009 Error reading additional data field of firmware message. Developer reserved: Additional debug information dependant on error type. Developer reserved: Additional debug information dependant on error type. Developer reserved: Additional debug information dependant on error type. Developer reserved: Additional debug information dependant on error type. Developer reserved: Additional debug information dependant on error type. Developer reserved: Additional debug information dependant on error type. Developer reserved: Additional debug information dependant on error type. Developer reserved: Additional debug information dependant on error type. Developer reserved: Additional debug information dependant on error type. Developer reserved: Additional debug information dependant on error type. Developer reserved: Additional debug information dependant on error type. Developer reserved: Additional debug information dependant on error type. Developer reserved: Additional debug information dependant on error type. Developer reserved: Additional debug information dependant on error type.

bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

= = = = = = = = = = = = = =

Originator = 302 MOSICCPST, 816 TOSICCPST This error occurs due to an internal error within the inter-processor links standby transmit task.
aaaa = Internal error type: 0001 Unable to get a memory block for received message. 0002 Unable to write the message into the links transmit queue. 0003 Error converting firmware message. 0004 Invalid link control command received from application software. Developer reserved: Additional debug information dependant on error type. Developer reserved: Additional debug information dependant on error type. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

= = = = = = = = = = = = = =

A30808-X3247-K240-3-7619

271

Outputs OML:BSC

Base Station Controller

Originator = 305 MOSICILEM During normal operations the IXLT alarm interface task on MPCC processor could not activate one of the operating system services (message reception or sending, memory allocation), though it repeatedly tried to do it.
aaaa = bbbb = cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = Used by designers to identify checkpoint. task instance identity; it may only assume value 0 or 1 according to the controlled IXLT copy Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

Originator = 312 MOSICIOPI This error occurres when a system call has failed.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = 0x8 - Allocation of a buffer failed. Length of the requested buffer. System call return value. It indicates the call point. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

272

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Originator = 313 MOSICILPD An operating system function, called by T-interface packet splitting task, failed.
aaaa = Used by the designer as an internal error code; its value can be: - 0002 (timeout not created); - 0003 (buffer not allocated); - 0009 (message send failure). Number of the source code line where error was issued. Job number value of I/O header. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

= = = = = = = = = = = = = =

Originator = 314 MOSICILSH An operating system function, called by BSC Symbolic names handler task, failed.
aaaa = Used by the designer as an internal error code; its value can be: - 0004 (buffer not allocated); - 0005 (message send failure). Number of the source code line where error was issued. Job number value of I/O header. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

= = = = = = = = = = = = = =

A30808-X3247-K240-3-7619

273

Outputs OML:BSC

Base Station Controller

Originator = 315 MOSICLFUP An operating system function, called by BSC Upload of proprietary log files task, failed.
aaaa = Used by the designer as an internal error code; its value can be: - 0001 (message send failure); - 0002 (buffer not allocated). Number of the source code line where error was issued. Transfer identifier (most significant word). Transfer identifier (least significant word). Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

= = = = = = = = = = = = = =

Originator = 316 MOSICUTBM This error occurres when a system call has failed.
aaaa = 0x13 - Memory Partition failed. 0x14 - Allocation data buffer failed. 0x15 - Release data buffer failed. 0x16 - Identification of the currently executing task failed. 0x17 - Modification the contents of a task's notepad register failed. System call return value. If aaaa=0x15, 0x16, 0x17 indicates the call point. If aaaa=0x14, indicates the task entry point. If aaaa=0x14, indicates the task entry point. If aaaa=0x14, indicates the pool number. If aaaa=0x14, indicates the length of buffer requested. If aaaa=0x14, indicates the length of buffer requested. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

bbbb = cccc = dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = =

Originator = 317 MOSICUTMT

274

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

This error occurres when a system call has failed.


aaaa = 0x18 - Creation of a PSOS message queue failed. 0x19 - Deletion of a PSOS message queue failed. 0x1A - Request message from the specified mailbox failed. 0x1B - Message sending failed. System call return value. If aaaa=0x1A, indicates the logical mailbox id. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

= = = = = = = = = = = = = =

Originator = 318 MOSICUSSC, 505 MSDSMCTMA One of the operating system functions, called by Compression task or Upload Server, failed.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to lacate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to lacate the instruction (line of third calling instruction). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any). Used by the designer Used by the designer Used by the designer Used by the designer Used by the designer Not used. Not used.

Originator = 504 MSDLSXCCT, 750 TSDLSXCCT This error occurs if the MPCC or TDPC Crosscopy fails.
aaaa = Link trace / internal error. 0000 Link trace information for unsuccessful crosscopy other Line number of internal error. Developer reserved: Current internal link time / internal error additional debug infomation.

bbbb =

A30808-X3247-K240-3-7619

275

Outputs OML:BSC
cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = =

Base Station Controller

Developer reserved: Number of link events / internal error additional debug information. Developer reserved: Link event or error and time occurred / Not used. Developer reserved: Link event or error and time occurred / Not used. Developer reserved: Link event or error and time occurred / Not used. Developer reserved: Link event or error and time occurred / Not used. Developer reserved: Link event or error and time occurred / Not used. Developer reserved: Link event or error and time occurred / Not used. Developer reserved: Link event or error and time occurred / Not used. Developer reserved: Link event or error and time occurred / Not used. Developer reserved: Link event or error and time occurred / Not used. Developer reserved: Link event or error and time occurred / Not used. Developer reserved: Link event or error and time occurred / Not used. Developer reserved: Link event or error and time occurred / Not used.

Originator = 504 MSDLSXCCT, 750 TSDLSXCCT This error occurs if the MPCC or TDPC Crosscopy fails.
aaaa = Link trace / internal error. 0000 Link trace information for unsuccessful crosscopy. other Line number of internal error. Developer reserved: Current internal link time / internal error additional debug infomation. Developer reserved: Number of link events / internal error additional debug information. Developer reserved: Link event or error and time occurred / Not used. Developer reserved: Link event or error and time occurred / Not used. Developer reserved: Link event or error and time occurred / Not used. Developer reserved: Link event or error and time occurred / Not used. Developer reserved: Link event or error and time occurred / Not used. Developer reserved: Link event or error and time occurred / Not used. Developer reserved: Link event or error and time occurred / Not used. Developer reserved: Link event or error and time occurred / Not used. Developer reserved: Link event or error and time occurred / Not used. Developer reserved: Link event or error and time occurred / Not used. Developer reserved: Link event or error and time occurred / Not used. Developer reserved: Link event or error and time occurred / Not used.

bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

= = = = = = = = = = = = = =

Originator = 510 MOSIWROMA An errorCollector function is called when Operating System Interworking task is unable to create itself. This occurs when t_create function returns an unsuccessful result
aaaa = bbbb = Source code line Used by the designer to indicate the Error description -IW_AUDIT_TASK_NOT_CREATED

276

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = = = = = = = = = = Used by the designer to indicate the source_sys Used by the designer to indicate the dest_sys Used by the designer to indicate the flags Used by the designer to indicate the source_mbx Used by the designer to indicate the destination Used by the designer to indicate the signal_type Used by the designer to indicate the signal_subtype Used by the designer to indicate the datalen Used by the designer to indicate the operationcode Used by the designer to indicate the message_type Not used Not used Not used

cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

Originator = 511 MOSIWROCO, 512 MOSIWRORE, 513 MOSIWROSP Interworking task has received a corrupted datalen message field
aaaa = bbbb = Source code line Used by the designer to indicate the Error description -COSIW_CORRUPTED_DATA Used by the designer to indicate the source_sys Used by the designer to indicate the dest_sys Used by the designer to indicate the flags Used by the designer to indicate the source_mbx Used by the designer to indicate the destination Used by the designer to indicate the signal_type Used by the designer to indicate the signal_subtype Used by the designer to indicate the CORRUPTED datalen Used by the designer to indicate the operationcode Used by the designer to indicate the message_type Not Used Not Used Not Used

cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

= = = = = = = = = = = = =

Originator = 513 MOSIWROSP,515 MOSIWMEMA,517 MOSIWMEST,518 MOSIWMEAL,520 MOSIWMEME An error is occurred when Operating System Interworking task is unable to retrieve software version value
aaaa = bbbb = Source code line Used by the designer to indicate the Error description -SW_VERSION_NOT_RETRIEVED Used by the designer to indicate the source_sys Used by the designer to indicate the dest_sys Used by the designer to indicate the flags

cccc = dddd = eeee =

A30808-X3247-K240-3-7619

277

Outputs OML:BSC
ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = Used by the designer to indicate the source_mbx Used by the designer to indicate the destination Used by the designer to indicate the signal_type Used by the designer to indicate the signal_subtype Used by the designer to indicate the datalen Used by the designer to indicate the operationcode Used by the designer to indicate the message_type Not used Not used Not used

Base Station Controller

Originator = 510 MOSIWROMA,511 MOSIWROCO,512 MOSIWRORE,515 MOSIWMEMA,516 MOSIWMEMI,517, MOSIWMEST,518 MOSIWMEAL,519 MOSIWMETE,520 MOSIWMEME, An errorCollector function is called when Operating System Interworking task is unable to allocate output buffer. This occours when safe_get_msg function returns an unsuccessful result.
aaaa = bbbb = Source code line Used by the designer to indicate the Error description -BUFFER_NOT_ALLOCATED_TO_A. Occurred when Interworking task is unable to allocate memory to build messages addressed to Abis/Asub interface -BUFFER_NOT_ALLOCATED_TO_T.Occurred when Interworking task is unable to allocate memory to build messages addressed to OMC/LMT system Used by the designer to indicate the source_sys Used by the designer to indicate the dest_sys Used by the designer to indicate the flags Used by the designer to indicate the source_mbx Used by the designer to indicate the destination Used by the designer to indicate the signal_type Used by the designer to indicate the signal_subtype Used by the designer to indicate the datalen Used by the designer to indicate the operationcode Used by the designer to indicate the message_type Not used Not used Not used

cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

= = = = = = = = = = = = =

Originator = 510 MOSIWROMA,511 MOSIWROCO,512 MOSIWRORE,513 MOSIWROSP,515 MOSIWMEMA,516 MOSIWMEMI,517, MOSIWMEST,518 MOSIWMEAL,519 MOSIWMETE,520 MOSIWMEME, An errorCollector function is called when Operating System Interworking task is unable to send output messages. This occours when c_tsk_msg_send function returns an unsuccessful result.
278 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
Source code line Used by the designer to indicate the Error description -MSG_SEND_FAILED_TO_A. Occurred when Interworking task is unable to send messages addressed to Abis/Asub interface -MSG_SEND_FAILED_TO_T.Occurred when Interworking task is unable to send messages addressed to OMC/LMT system Used by the designer to indicate the source_sys Used by the designer to indicate the dest_sys Used by the designer to indicate the flags Used by the designer to indicate the source_mbx Used by the designer to indicate the destination Used by the designer to indicate the signal_type Used by the designer to indicate the signal_subtype Used by the designer to indicate the datalen Used by the designer to indicate the operationcode Used by the designer to indicate the message_type Not used Not used Not used

aaaa = bbbb =

cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

= = = = = = = = = = = = =

Originator = 600 MSDBACTDA, 603 MSDBACTMA, 604 MSDBACTIA, 605 MSDBACTPA, 606 MSDBACTTA One of the operating system functions, called by PPLD controller task or MPCC controller task or IXLT controller task or PPCC controller task or TDPC controller task, failed.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction). Used by the designer to locate the instruction (line of second calling instruction). Used by the designer to locate the instruction (file id of third calling instruction). Used by the designer to locate the instruction (line of third calling instruction). Used by the designer to locate the instruction (file id of fourth calling instruction). Used by the designer to locate the instruction (line of fourth calling instruction). Not used. Not used. Not used. Not used. Not used. Not used. Not used.

Originator = 625 MSDRIBSIU Trans_up/down_received message sending failure


A30808-X3247-K240-3-7619 279

Outputs OML:BSC
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = line where the error is occurred Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used

Base Station Controller

Originator = 700 TOSSDATPL During a Dedicated Load it was not possible to activate an operating system service (message reception/sending, memory allocation), though it repeatedly tried to do it.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to locate the instruction (line of third calling instruction, if any). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any). Not used. Not used. Not used. Not used. Not used. Not used. Not used.

Originator = 972 XOSICIOPT The Send_message function returned an error


aaaa bbbb cccc dddd eeee = = = = = SEND_MESSAGE_FAILED error code returned by the called function souce system destinadion system source mailbox

280

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = = = = = = = destination mailbox signal type signal subtype message length Not used. Not used. Not used. Not used. Not used. Not used.

ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

Originator = 2000 MDATABASE The error occurs if a system call function fails
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Source C line Source C file identifier Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used

Originator = 2001 MDBCADHDE A problem during a dba server abis/asub procedure has been detected: fail sending/receiving message on interface or unexpected nack or message received out of sequence.
aaaa = bbbb = Source module line number where error is emitted Depends on the source C line thid field can be: 1) Absolute network element involved in running operation. 2) developer oriented Depends on the source C line this field can be: 1) Originator module where error was detected. 2) developer oriented Depends on the source C line thid field can be : 1) Line of error detection, used by the designer to locate the instruction. 2) developer oriented Depends on the source C line this field can be: 1) Internal error code, used by the designer to locate the instruction.

cccc =

dddd =

eeee =

A30808-X3247-K240-3-7619

281

Outputs OML:BSC
ffff =

Base Station Controller

gggg =

hhhh iiii jjjj kkkk llll mmmm nnnn oooo

= = = = = = = =

2) developer oriented Depends on the source C line this field can be : 1) Event tha trigger the running transition, used by the designer to locate the instruction.. 2) developer oriented Depends on the source C line this field can be: 1) Procedure result, used by the designer to locate the instruction. 2) developer oriented developer oriented developer oriented Not Used Not Used Not Used Not Used Not Used Not Used

Originator = 2100 CDBMDBFH A system call function fails


aaaa = bbbb = Source C line Depends on the source C line, this field can be: 1) Not Used 2) Used by the designer to indicate the error number value Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used

cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

= = = = = = = = = = = = =

Originator = 2222 CDBMDHSA A system call function fails


aaaa = bbbb = Source C line Depends on the source C line, this field can be: 1) Not Used 2) Used by the designer to indicate error number value related to open/write/close operation on file 3) Used by the designer to indicate a negative results from the function called to obtain

282

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
parameters of SCA/RFLOOP Depends on the source C line, this field can be: 1) Not Used 2) Used by the designer to indicate the current number of SCA/RFLOOP object Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used

cccc =

dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

= = = = = = = = = = = =

Originator = 2600 TDATABASE The error occurs if it is not possible to send the responce message to updating message because a system call fails
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used

Originator = 3000 MSMARECCO, 3500 TSMARECCO Error collector has required to OS a buffer, but the response was negative.
aaaa bbbb cccc dddd eeee ffff = = = = = = Source code line of the calling module Error identifier of the original fault. Mnemonic of the object involved. First address of the object involved. Second address of the object involved. Third address of the object involved.

A30808-X3247-K240-3-7619

283

Outputs OML:BSC
gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = Fourth address of the object involved. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

Base Station Controller

Originator = 3000 MSMARECCO, 3500 TSMARECCO Error collector/ceased on MPCC or TDPC has sent a buffer to OS, but the response was negative.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Source code line of the module (designer oriented). System Information identifier Mnemonic of the object involved. First address of the object involved. Second address of the object involved. Third address of the object involved. Fourth address of the object involved. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

Originator = 3000 MSMARECCO, 3500 TSMARECCO Error collector/ceased on MPCC or TDPC has requested a buffer to OS, but the response was negative.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj = = = = = = = = = = Originator of the module that found the error. Source code line of the module that found the error. Error collector/ceased internal error. Error identifier found during the processing. Not used Mnemonic of the object involved. First address of the object involved. Second address of the object involved. Third address of the object involved. Fourth address of the object involved.

284

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = = Not used. Not used. Not used. Not used. Not used.

kkkk llll mmmm nnnn oooo

Originator = 3010 MSMAREPDE Error processor delay task on MPCC has sent a message to OS, but the response was negative.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Source code line of the delay module. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

Originator = 3011 MSMAREPCO Error processor has sent a message to OS, but the response was negative.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Source code line of the error processor module. Error or Probable Cause of the fault received to process. Mnemonic of the object involved. First address of the object involved. Second address of the object involved. Third address of the object involved. Fourth address of the object involved. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

A30808-X3247-K240-3-7619

285

Outputs OML:BSC

Base Station Controller

Originator = 3012 MSMAREPHA Error processor on MPCC has requested a buffer to OS, but the response was negative.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Source code line of the error processor module. Error identifier that error processor was managing before the it found the problem. Mnemonic of the object involved. First address of the object involved. Second address of the object involved. Third address of the object involved. Fourth address of the object involved. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

Originator = 3110 MSMSHHDHQ This error is called when Status Manager try to enqueue an LOCKED object in LOCK LIST but there are 50 objects enqueued jet.So Status Manager doesn't remember all locked objects and,after a full initialization,some devices will remain in UNLOCKED state.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Action Mnemonic Unit address[0] Unit address[1] Unit address[2] Unit address[3] source line not used not used not used not used not used not used not used not used

286

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Originator = 3141 MSMSHPCCD This error is called when Status Manager requests an Operating System buffer but there is not memory available.So Status Manager wait till a buffer is available and then continues to process the command.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = source line Mnemonic Unit address[0] Unit address[1] Unit address[2] Unit address[3] Action Transition index not used not used not used not used not used not used not used

Originator = 4000 MDHACENIN A system call has failed in the case of create the audit task mailbox. The function of Operating System that create the mailbox has failed. So the audit of external alarms can't be performed.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Source code line number of module that generate this error. not used. not used. not used. not used. not used. not used. not used. not used. not used. not used. not used. not used. not used. not used.

A30808-X3247-K240-3-7619

287

Outputs OML:BSC

Base Station Controller

Originator = 4403 MDHLCUTGE A Device Handler of some object has issued a service request with wrong parameters to the LICD Device Handler.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Developer reserved: code line number where error is emitted Developer reserved: Type of error occurred Developer reserved: code line number where error is detected Originator of error detection Developer reserved: Mnemonic of object involved with issued request: mnem Developer reserved: Mnemonic of object involved with issued request: maddr[0] Developer reserved: Mnemonic of object involved with issued request: maddr[1] Developer Reserved: Mnemonic of object involved with issued request: maddr[2] Not used. Not used. Not used. Not used. Not used. Not used. Not used.

Originator = 4455 MDHIXDCUF this error occurs when the programming onto LICD of the AINT link towards OMC failed.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = the line number of the source module the IXLT supporting the link the type of programming: set of link (1) or reset of link (0) not used not used not used not used not used not used not used not used not used not used not used not used

288

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Originator = 4501 MDHXXDCDE This error is issued if fsdsmGetExeSvr() routine fails inside Load Service End case of ldMsg routine.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = source item index line where the problem was found error code line where the routine handling the fault was called card absolute number Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

Originator = 4503 MDHXXDCSA This error message is issued if a call of c_tsk_msg_send (RTE utility) fails during an internal alarm management inside PPxx Device Handler
aaaa = Bit masks of alarmed PPLD (or PPCC or PPCU): PPLD occupy bits from position 1 to position 15 from the right (card number from 0 to 14); PPCC occupy bits 16 and 17 (absolute number in PPxx DH: 15 and 16, corresponding to PPCC-0 and PPCC-1), PPCU use bits from 18 to 21 (absolute numeration from 17 to 20, which correspond to PPCU 0,1,2,3). Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used

bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

= = = = = = = = = = = = = =

A30808-X3247-K240-3-7619

289

Outputs OML:BSC

Base Station Controller

Originator = 4508 MDHXXGSUT This error message is issued when a mailbox creation fails during xxcuDba routine, called by fdhxx_lapd_cmd and fdhxx_frl_cmd utilities respectively for LAPD Create/Delete and FRL Create/Set/Delete.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Absolute LAPD or FRL identifier Operation code (0x91 = T_CREATE, 0x92 = T_DELETE, 0x93 = T_SET) Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used

Originator = 4514 MDHXXLUSA This error message is issued if a call of c_tsk_msg_send (RTE utility) fails during an internal alarm management inside PPxx Device Handler
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = internal error code source code line absolute card intance not used not used not used not used not used not used not used not used not used not used not used not used

Originator = 4609 MDHPRDCHL, 4902 TDHPRDCHL

290

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

The initialization of the Memory Align Server failed.


aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = The line of the module where the error is issued. The messages' handle. The OS timer pointer. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

Originator = 5000 CPM_MPCC_ORIGINATOR This error occurs when a system function call fails for system resources exhaustion (memory, buffers, timer). All related additional info are developer oriented and useful for debugging activity
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Module that generates the error. Source code line of the module that generates the error. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use.

Originator = 5001 CPM_IMSI_ORIGINATOR This error comes issued when there are problems about the set of timer or during the sending of a message by IMSI Trace tasks, or at the creation of a task. All related additional info are developer oriented and useful for debugging activity

A30808-X3247-K240-3-7619

291

Outputs OML:BSC
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Module that generates the error. Source code line of the module that generates the error. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use.

Base Station Controller

Originator = 5002 CPM_CTR_ORIGINATOR This error comes issued when there are problems during the sending of a message by CTR tasks or at the creation of a task. All related additional info are developer oriented and useful for debugging activity
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Module that generates the error. Source code line of the module that generates the error. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use.

Originator = 5100 CPM_PCUC_ORIGINATOR This error occurs when a system function call fails. All related additional info are developer oriented and useful for debugging activity
aaaa = bbbb = Module that generates the error. Source code line of the module that generates the error.

292

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = = = = = = = = = = Source code line of the module that generates the error. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use.

cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

Originator = 5500 CPM_TDPC_ORIGINATOR This error occurs when a system function call fails.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Source module that generates the error. Source code line of the module that generates the error. Source code line of the module that generates the error. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use.

Originator = 7000 TL3N7SCOC050, 7001 TL3N7SCOC060, 7002 TL3N7SCLC010, 7004 TL3N7TMSCOC030, 7005 TL3N7SCOC020, 7006 TL3N7SCOC010, 7007 TL3N7SCRC010, 7008 TL3N7SCPI030, 7009 TL3N7SCPI020, 7010 TL3N7SCPI010, 7011 TL3N7LTST1, 7012 TL3N7UTIH1, 7013 TL3N7LMAC2, 7014 TL3N7TST2, 7016 TL3N7TST3, 7018 TL3N7DIST1, 7022 TL3N7LMAC3, 7023 TL3N7LMAC4, 7024 TL3N7LMAC5, 7025 TL3N7LMAC1, 7026 TL3N7TMLA1, 7027 TL3N7TMLA2, 7028 TL3N7TMSR1, 7032 TL3N7TMCB2, 7033 TL3N7TMCB3, 7034 TL3N7TMCB4, 7035 TL3N7TMCB5, 7036 TL3N7TMCO1, 7037 TL3N7TMCO2, 7038 TL3N7TMCO3, 7039 TL3N7TMCO4, 7040 TL3N7TMCO5, 7041 TL3N7TMCO6, 7042 TL3N7TMCO7, 7043 TL3N7TMCO8, 7045 TL3N7SCMG010, 7046 TL3N7UTER1, 7050 TL3N7GEMR1, 7053 TL3N7TMFC1, 7054 TL3N7GESG1, 7057 TL3N7GESG4, 7058 TL3N7GESG5

A30808-X3247-K240-3-7619

293

Outputs OML:BSC

Base Station Controller

This error is generated in case of unsuccessful response at buffer allocation request.


aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Instance Process State EDOS Signal (see annex D for more details) Type of the requested pool. Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used

Originator = 9000 MDGDMPIPR Diagnostic manager tries to format a message to LMT/OMC (create/delete notification, ACK/NACK stop, get test) or to executor task to cancel a test, but safe_tsk_msg_send() function doesn't work correctly.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = <source line> < DGMSGSEND 0x1> not used. not used. not used. not used. not used. not used. not used. not used. not used. not used. not used. not used. not used.

Originator = 9000 MDGDMPIPR This error is called in the following cases: 1 - Diagnostic Manager tries to create a mailbox but the c_create_mbx() or c_mbx_public() functions dont work properly (executor task test activation, DH test end ).
294 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

2 - Diagnostic Manager exchanges messages with DH to stop a diagnostic. The message received is a timeout or safe_tsk_msg_send() function doesn't work correctly.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = <source line> < signal_subtype> < mnemonic > not used not used not used not used not used not used not used not used not used not used not used not used

Originator = 9000 MDGDMPIPR This error is called in the following cases: 1 - Diagnostic Manager exchanges messages with DH to activate a diagnostic. The message received is a timeout or safe_tsk_msg_send() function doesn't work correctly.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = <source line> < mnemonic > not used not used not used not used not used not used not used not used not used not used not used not used not used

Originator = 9001 MDGDMDAPR This error is called in the following cases: 1 - Diagnostic Manager exchanges messages with executor task to activate a diagnostic. The message received is a timeout or safe_tsk_msg_send() function doesn't work correctly.
aaaa = <source line>

A30808-X3247-K240-3-7619

295

Outputs OML:BSC
bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = < signal_subtype> < instance > not used. not used. not used. not used. not used. not used. not used. not used. not used. not used. not used. not used.

Base Station Controller

Originator = 9002 MDGDMOUPR Diagnostic manager tries to format a message to LMT/OMC (test result, test object alignment response) but safe_tsk_msg_send() function doesn't work correctly.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = <source line> < DGMSGSEND 0x1> not used. not used. not used. not used. not used. not used. not used. not used. not used. not used. not used. not used. not used.

Originator = 9003 MDGDMPEPR, 9005 TDGDMPEPR Executor task tries to format a message to Diagnostic manager (test in progress and test result) but safe_tsk_msg_send() function doesn't work correctly.
aaaa bbbb cccc dddd eeee = = = = = <source line> < DGMSGSEND 0x1> not used. not used. not used.

296

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = = = = = = = not used. not used. not used. not used. not used. not used. not used. not used. not used. not used.

ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

Originator = 9003 MDGDMPEPR, 9005 TDGDMPEPR Executor task tries to create a mailbox (to receive message from Diagnostic Manager or send test in progress response) but the c_create_mbx()functions dont work properly ().
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = <source line> < instance > < mot > not used not used not used not used not used not used not used not used not used not used not used not used

Originator = 10101 MFTIH, 10102 MFTRS It indicates that an error occires during a msg_send or msg_receive call performed by FTAM tasks
aaaa bbbb cccc dddd eeee ffff gggg hhhh = = = = = = = = designer oriented: an integer identifing the module where the failed system call is performed designer oriented: the line (Hex value) where the failed system call is perfomed. return value of the failed system call not used not used not used not used not used

A30808-X3247-K240-3-7619

297

Outputs OML:BSC
iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = not used not used not used not used not used not used not used

Base Station Controller

Originator = 10103 MBACW It indicates that a function call by BSC Agent Class Worker task has failed
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = designer oriented: an integer identifing the module where the failed system call is performed designer oriented: the line (Hex value) where the failed system call is perfomed. return value of the failed system call not used not used not used not used not used not used not used not used not used not used not used not used

Originator = 10103 MBACW It indicates that a function call by BSC Agent Class Worker task has failed
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm = = = = = = = = = = = = = designer oriented: an integer identifing the module where the failed system call is performed designer oriented: the line (Hex value) where the failed system call is perfomed. not used not used not used not used not used not used not used not used not used not used not used

298

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
not used not used

nnnn = oooo =

Originator = 10104 MBAMW It indicates that an error occurs during a Psos system call or an Api system call by originating subsystem of BSS Agent area, where the call is performed with parameter System call unsuccesfull warning.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = designer oriented: an integer identifing the module where the failed system call is performed designer oriented: the line (Hex value) where the failed system call is perfomed. return value of the failed system call not used not used not used not used not used not used not used not used not used not used not used not used

Originator = 10106 MBAMW It indicates that a function call by BSC Agent Mit Aligner task has failed.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = designer oriented: an integer identifing the module where the failed system call is performed designer oriented: the line (Hex value) where the failed system call is perfomed. not used not used not used not used not used not used not used not used not used not used not used not used not used

A30808-X3247-K240-3-7619

299

Outputs OML:BSC

Base Station Controller

Originator = 10106 MBAMW A log record is rejected because it exceeds the maximum dimension allowed by the system.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = designer oriented: an integer identifing the module where the failed system call is performed designer oriented: the line (Hex value) where the failed system call is perfomed. dimension (byte) of the rejected log record not used not used not used not used not used not used not used not used not used not used not used not used

Originator = 10106 MBAMW It indicates that a function call by BSC Agent Mit Aligner task has failed.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = designer oriented: an integer identifing the module where the failed system call is performed designer oriented: the line (Hex value) where the failed system call is perfomed. return value of the failed system call not used not used not used not used not used not used not used not used not used not used not used not used

Originator = 10107 MBAAW It indicates that a function call by BSC Agent Agent Worker task has failed
aaaa = bbbb = designer oriented: an integer identifing the module where the failed system call is performed designer oriented: the line (Hex value) where the failed system call is perfomed.

300

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = = = = = = = = = = return value of the failed system call not used not used not used not used not used not used not used not used not used not used not used not used

cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

Originator = 10107 MBAAW It indicates that a function call by BSC Agent Agent Worker task has failed
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = designer oriented: an integer identifing the module where the failed system call is performed designer oriented: the line (Hex value) where the failed system call is perfomed. not used not used not used not used not used not used not used not used not used not used not used not used not used

Originator = 10107 MBAAW It indicates that a function call by BSC Agent Agent Worker task has failed
aaaa = bbbb = cccc = dddd eeee ffff gggg hhhh = = = = = designer oriented: an integer identifing the module where the failed system call is performed designer oriented: the line (Hex value) where the failed system call is perfomed. pointer to the Object Identifier that the function failed to copy. This parameter is meaningful when it refers to a static global structure not used not used not used not used not used

A30808-X3247-K240-3-7619

301

Outputs OML:BSC
iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = not used not used not used not used not used not used not used

Base Station Controller

Originator = 10108 MQ3CB Error calling a PSOS timer function.


aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = (developer oriented) Source module (developer oriented) Number of source module line (developer oriented) Error code not used not used not used not used not used not used not used not used not used not used not used not used

##StartSpecProbl##
Specific Problems = 030 SYSTEM CALL UNSUCCESSFUL PRIME TASK INIT

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 410 MOSKNMSEH/901 TOSKNMSEH This error can be generated by two different events: you can distinguish using the first field of the message. The periodic audit of the scheduling queues pointed out that a task in the Prime Time
302 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

queues didn't give up the control. The system causes a Task Prime Initialization to delete the problem. An interrupt occured and the system as a defense action is trying to delete the current task when a second interrupt occurs generating a task abort loop. The informations about the current task are shown in the following messages. The system causes a Task Prime Initialization to resolve the problem.
aaaa = 0x25 SCH AUDIT ERROR TP (Scheduler Audit error) 0x26 SCH AUDIT ERROR TS (Scheduler Audit error) 0x1F FULL INIT RQ (Interrupt loop) last priority scheduled by RTE+ scheduler (meaningful for Scheduler Audit error) number of Prime Task init requested by Scheduler Audit (low word, meaningful for Scheduler Audit error) number of Prime Task init requested by Scheduler Audit (high word, meaningful for Scheduler Audit error) not used not used not used not used not used not used not used not used not used not used not used

bbbb = cccc = dddd = eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = =

Originator = 641 MPSOSCALL The error is issued when a pSOS system call fails returning an error code and an initialization is required
aaaa = bbbb = cccc = Used by designer to locate the module where the error is issued. Line in the code where the error is issued. Identifier of the failed pSOS system calls. It can assume one of the following values: 0x01 (T_CREATE_LBL) => t_create 0x02 (T_DELETE_LBL) => t_delete 0x03 (T_GETREG_LBL) => t_getreg 0x04 (T_IDENT_LBL) => t_ident 0x05 (T_MODE_LBL) => t_mode 0x06 (T_RESTART_LBL) => t_restatrt 0x07 (T_RESUME_LBL) => t_resume 0x08 (T_SETPRI_LBL) => t_setpri 0x09 (T_SETREG_LBL) => t_setreg 0x0A (T_START_LBL) => t_start 0x0B (T_SUSPEND_LBL) => t_suspend 0x11 (Q_BROADCAST_LBL) => q_broadcast 0x12 (Q_CREATE_LBL) => q_create 0x13 (Q_DELETE_LBL) => q_delete 0x14 (Q_IDENT_LBL) => q_ident 0x15 (Q_RECEIVE_LBL) => q_receive 0x16 (Q_SEND_LBL) => q_send 0x17 (Q_URGENT_LBL) => q_urgent 0x18 (TAB_CORRUPT_LBL) => error during updating of PTT or TIT 0x19 (DE_INIT_LBL) => de_init 0x1A (DE_CNTRL_LBL) => de_cntrl 0x1B (DE_WRITE_LBL) => de_write

A30808-X3247-K240-3-7619

303

Outputs OML:BSC
dddd =

Base Station Controller

eeee = ffff =

gggg = hhhh =

iiii = jjjj =

0x1C (DE_READ_LBL) => de_read If the field cccc assumes the value 0x18 it is the bad value returned by the function that produced the error; otherwise it is the error code returned by pSOS system call (rtn_Psos_Error). It is the second word of the variable contained in field dddd. Assumes a different meaning according to the value of field cccc, as shown below: Field cccc => Field ffff 0x01 => Task name (name) 0x02 => Not used 0x03 => Register number (regnum) 0x04 => Task name (name) 0x05 => Attributes to be changed (mask) 0x06 => First startup argument (targs[0]) 0x07 => Not used 0x08 => New priority (newprio) 0x09 => Register number (regnum) 0x0A => Initial task attributes (mode) 0x0B => Not used 0x11 => First field in message buffer (msg_buf[0]) 0x12 => Queue name (name) 0x13 => Not used 0x14 => Queue name (name) 0x15 => Queue attributes (flags) 0x16 => First field in message buffer (msg_buf[0]) 0x17 => First field in message buffer (msg_buf[0]) 0x18 => Not used. 0x19 => Device Major number 0x1A => Device Major number 0x1B => Device Major number 0x1C => Device Major number It is the second word of the variable contained in field ffff. Assumes a different meaning according to the value of field cccc, as shown below: Field cccc => Field hhhh 0x01 => Task priority (prio) 0x02 => Not used 0x03 => Not used 0x04 => Node number (node) 0x05 => New attributes (newmode) 0x06 => Second startup argument (targs[1]) 0x07 => Not used 0x08 => Not used 0x09 => Register value (regvalue) 0x0A => Task address (start_address) 0x0B => Not used 0x11 => Second field in message buffer (msg_buf[1]) 0x12 => Queue size (count) 0x13 => Not used 0x14 => Node number (node) 0x15 => Timeout in clock ticks (timeout) 0x16 => Second field in message buffer (msg_buf[1]) 0x17 => Second field in message buffer (msg_buf[1]) 0x18 => Not used. 0x19 => Device Minor number 0x1A => Device Minor number 0x1B => Device Minor number 0x1C => Device Minor number It is the second word of the variable contained in field hhhh. Assumes a different meaning according to the value of field cccc, as shown below: Field cccc => Field jjjj 0x01 => Task attributes (flags) 0x02 => Not used 0x03 => Not used 0x04 => Not used 0x05 => Not used 0x06 => Third startup argument (targs[2]) 0x07 => Not used 0x08 => Not used 0x09 => Not used

304

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
0x0A => First startup argument (targs[0]) 0x0B => Not used 0x11 => Third field in message buffer (msg_buf[2]) 0x12 => Queue attributes (flags) 0x13 => Not used 0x14 => Not used 0x15 => Not used 0x16 => Third field in message buffer (msg_buf[2]) 0x17 => Third field in message buffer (msg_buf[2]) 0x18 => Not used. 0x19 => Not used. 0x1A => Not used. 0x1B => Not used. 0x1C => Not used. It is the second word of the variable contained in field jjjj. Assumes a different meaning according to the value of field cccc, as shown below: Field cccc => Field llll 0x01 => Not used 0x02 => Not used 0x03 => Not used 0x04 => Not used 0x05 => Not used 0x06 => Fourth startup argument (targs[3]) 0x07 => Not used 0x08 => Not used 0x09 => Not used 0x0A => Second startup argument (targs[1]) 0x0B => Not used 0x11 => Fourth field in message buffer (msg_buf[3]) 0x12 => Not used 0x13 => Not used 0x14 => Not used 0x15 => Not used 0x16 => Fourth field in message buffer (msg_buf[3]) 0x17 => Fourth field in message buffer (msg_buf[3]) 0x18 => Not used. 0x19 => Not used. 0x1A => Not used. 0x1B => Not used. 0x1C => Not used. It is the second word of the variable contained in field llll. pSOS entry point of the current task (PsosEntryPoint). The value 0x0000 makes the field invalid and meaningless. It is the second word of the variable contained in field nnnn.

kkkk = llll =

mmmm = nnnn = oooo =

Originator = 642 MPSOSSTMOD Every pSOS task must receive as input parameter the start mode: it identifies the action that must be performed (start, restart, abort, etc.). The error is issued when this parameter is not valid and an initialization is required.
aaaa bbbb cccc dddd eeee ffff = = = = = = Used by designer to locate the module where the error is issued. Line in the code where the system info is issued. Not used. Invalid start mode value (value of the variable start_mode). It is the second word of the variable contained in field dddd. pSOS name of the task that should perform the action identified by the start mode parameter (name). The value "RTET" identifies a generic RTE+ application task; the value 0x0000 makes the field invalid and meaningless.

A30808-X3247-K240-3-7619

305

Outputs OML:BSC
gggg = hhhh = iiii = jjjj = kkkk llll mmmm nnnn oooo = = = = =

Base Station Controller

It is the second word of the variable contained in field ffff. pSOS entry point of the task that should perform the action identified by the start mode parameter (PsosEntryPoint). The value 0x0000 makes the field invalid and meaningless. It is the second word of the variable contained in field hhhh. pSOS identifier of the task that should perform the action identified by the start mode parameter (PsosId). The value 0x0000 makes the field invalid and meaningless. It is the second word of the variable contained in field jjjj. Not used. Not used. Not used. Not used.

Originator = 4098 MDHPCSAMA The scan work function that creates the MPCC audit task with the standby one doesn't succeeded in creating the task. The creation is retried several times before issue the error.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Line in the code where the error took place Designer use only value not used not used not used not used not used not used not used not used not used not used not used not used not used

##StartSpecProbl##
Specific Problems = 031 SYSTEM CALL UNSUCCESSFUL FULL INIT

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 3002 MSMGSSMFU, 3600 TSMGSSMFU The safe function is unable to operate during a task abort.
aaaa = bbbb = Source module Source code line

306

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = = = = = = = = = = Pool type requested Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used

cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

Originator = 10100 MQ3US The creation of a task or the get of a message has failed.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Source module Source code line Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used

##StartSpecProbl##
Specific Problems = 034 COMMAND REJECTED WARNING

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 126 MOSSDNSBL A command issued by the BTSE alignment task has been rejected by some other BSC task.
A30808-X3247-K240-3-7619 307

Outputs OML:BSC
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = =

Base Station Controller

Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to locate the instruction (line of third calling instruction, if any). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any). NE whose alignment has failed. Failure cause. not used not used not used not used not used

Originator = 127 MOSSDNSTL A command issued by the TRAU alignment task has been rejected by some other BSC task.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to locate the instruction (line of third calling instruction, if any). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any). NE whose alignment has failed. Failure cause. not used not used not used not used not used

Originator = 128 MOSSDNSBC A command issued by the BTSE activation procedure on the BSC has been rejected by some BTSE.
aaaa bbbb cccc dddd eeee = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any).

308

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = = = = = = = Used by the designer to locate the instruction (line of third calling instruction, if any). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any). not used not used not used not used not used not used not used

ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

Originator = 129 MOSSDNSTC A command issued by the TRAU activation procedure on the BSC has been rejected by some TRAU.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to locate the instruction (line of third calling instruction, if any). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any). not used not used not used not used not used not used not used

Originator = 318 MOSICUSSC One of NEs sent a nack as a response to a request of the Upload Server
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj = = = = = = = = = = Used by the designer to lacate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to lacate the instruction (line of third calling instruction). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any). Number of process. Current state.

A30808-X3247-K240-3-7619

309

Outputs OML:BSC
kkkk llll mmmm nnnn oooo = = = = = Current event. Not used. Not used. Not used. Not used.

Base Station Controller

Originator = 510 MOSIWROMA A Command from LMT system with incompatible value between software version and Network Element instance is occurred
aaaa = bbbb = cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = Source code line Used by the designer to indicate the Error description Used by the designer to indicate the source_sys Used by the designer to indicate the dest_sys Used by the designer to indicate the flags Used by the designer to indicate the source_mbx Used by the designer to indicate the destination Used by the designer to indicate the signal_type Used by the designer to indicate the source_subtype Used by the designer to indicate the datalen Used by the designer to indicate the operationcode Used by the designer to indicate the message_type Not used Not used Not used

Originator = 5500 CPM_TDPC_ORIGINATOR Request result can't be supplied because of an allocation memory failure.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer as an internal error code; its value is 4. Source module that generates the error; its value is 1. Source code line of the module that generates the error. Scanner number. Size of memory block. 0 (not used). 0 (not used). 0 (not used). 0 (not used). 0 (not used). 0 (not used). 0 (not used). 0 (not used). 0 (not used). 0 (not used).

310

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Specific Problems = 053 INACCESSIBLE DUAM ERROR

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 500 MSDLSLTPI During an IXLT loading, a read or write operation on DUAM failed.
aaaa bbbb cccc dddd eeee ffff gggg hhhh = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). not used. not used. not used. not used. not used. Used to indicate processor type: 2 IXLT processor; 6 TDPC processor. Used to indicate processor number. Used to indicate the number of packet that the task was trying to write in DUAM (not used if read op, or used to indicate the data record type if end of load msg). Used to indicate the data record type (not used if read op or end of load msg). not used not used not used not used

iiii = jjjj = kkkk llll mmmm nnnn oooo = = = = =

Originator = 700 TOSSDATPL During a PPXX loading, a read operation on DUAM failed.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk = = = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to locate the instruction (line of third calling instruction, if any). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any). error code. not used. not used.

A30808-X3247-K240-3-7619

311

Outputs OML:BSC
llll mmmm nnnn oooo = = = = not used. not used. not used. not used.

Base Station Controller

Originator = 4980 NDHPDDCMA, 4990 YDHPDDCMA This error is issued by PPXU/PPXL Agent when, during an internal event hanling (Get or Set), an internal semaphore (for access to PPXX-MPCC DUAM) is found locked (it should be free).
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Source code line Not used Not used Not used Not used Not used Not used Not used Not used Not used. Not used. Not used. Not used. Not used. Not used.

312

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

46 TIMEOUT EXPIRED
FAILURE EVENT REPORT: NAME = Probable cause = Specific Problems = Event Type = Event Time = Severity = Trend Indication = Notification Identifier = Correlated Notification Identifier = Related MO = Proposed Repair Actions = Additional Text = Originator = Additional Words =
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo <R.T.D.>

<R.T.D.> <R.T.D.> Timeout Expired <see legend> <see legend> <R.T.D.> <see legend> <R.T.D.> <R.T.D.> <displayed only during Alarm Alignment> <R.T.D.> <R.T.D.> <see legend> <R.T.D.> <see legend>

Software Version =

Legend:

##StartSpecProbl##
Specific Problems = 033 TIMEOUT EXPIRED WARNING

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 124 MOSSDNDDL0 A timeout has expired while the BTSE download task was waiting for an acknowledgement from a NE.
aaaa bbbb cccc dddd eeee = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any).

A30808-X3247-K240-3-7619

313

Outputs OML:BSC
ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = =

Base Station Controller

Used by the designer to locate the instruction (line of third calling instruction, if any). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any). Expected message source system. Expected signal type. Expected signal subtype. Expected ABIS, ASUB, LMT or OMC operation code. Expected NE identifier. not used not used

Originator = 125 MOSSDNDDL1 A timeout has expired while the TRAU download task was waiting for an acknowledgement from a NE.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to locate the instruction (line of third calling instruction, if any). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any). Expected message source system. Expected signal type. Expected signal subtype. Expected ABIS, ASUB, LMT or OMC operation code. Expected NE identifier. not used not used

Originator = 126 MOSSDNSBL A timeout has expired when one the BTSE alignment task was waiting for an acknowledgement from another BSC task.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to locate the instruction (line of third calling instruction, if any). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any). Expected message source system.

314

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = = = Expected signal type. Expected signal subtype. Expected ABIS, ASUB, LMT or OMC operation code. Expected NE identifier. not used not used

jjjj kkkk llll mmmm nnnn oooo

Originator = 127 MOSSDNSTL A timeout has expired when the TRAU alignment task was waiting for an acknowledgement from another BSC task.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to locate the instruction (line of third calling instruction, if any). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any). Expected message source system. Expected signal type. Expected signal subtype. Expected ABIS, ASUB, LMT or OMC operation code. Expected NE identifier. not used not used

Originator = 128 MOSSDNSBC A timeout has expired when one the BTSE activation procedure on the BSC was waiting for an acknowledgement from a BTSE.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm = = = = = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to locate the instruction (line of third calling instruction, if any). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any). Expected message source system. Expected signal type. Expected signal subtype. Expected ABIS, ASUB, LMT or OMC operation code. Expected NE identifier.

A30808-X3247-K240-3-7619

315

Outputs OML:BSC
nnnn = oooo = not used not used

Base Station Controller

Originator = 129 MOSSDNSTC A timeout has expired when the TRAU activation procedure on the BSC was waiting for an acknowledgement from a TRAU.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to locate the instruction (line of third calling instruction, if any). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any). Expected message source system. Expected signal type. Expected signal subtype. Expected ABIS, ASUB, LMT or OMC operation code. Expected NE identifier. not used not used

Originator = 133 MOSSDFSDS During a download from the LMT/OMC to the BSC, the download task was waiting for a message from the LMT/OMC but too much time has passed.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to locate the instruction (line of third calling instruction, if any). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any). not used not used not used not used not used not used not used

316

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Originator = 136 MOSSDFSUD During an upload from the BSC to the LMT/OMC, the upload task was waiting for a message from the LMT/OMC but too much time has passed.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to locate the instruction. not used not used not used not used not used not used not used not used not used not used not used not used not used not used

Originator = 313 MOSICILPD A timeout has expired during the collection of packets in BSC T-interface packet splitting task.
aaaa = bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm = = = = = = = = = = = = Used by the designer as an internal error code; its value is: 000A (message reassembling interrupted). Number of the source code line where error was issued. Signal subtype value of RTE header. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

A30808-X3247-K240-3-7619

317

Outputs OML:BSC
nnnn = oooo = Not used. Not used.

Base Station Controller

Originator = 318 MOSICUSSC A timeout has expired during an Upload Procedure.


aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to lacate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to lacate the instruction (line of third calling instruction). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any). Number of process. Current state. Current event. Not used. Not used. Not used. Not used.

Originator = 500 MSDLSLTPI, 501 MSDLSLTPL, 503 MSDLSLTPT A timeout has expired during a Loading Procedure of IXLT or TDPC processor or TDPC/MPCC patches.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to lacate the instruction (file id of first calling instruction). Used by the designer to lacate the instruction (lineof first calling instruction). Used by the designer to lacate the instruction (file id of second calling instruction). Used by the designer to lacate the instruction (lineof second calling instruction). Used by the designer to lacate the instruction (file id of third calling instruction). Used by the designer to lacate the instruction (lineof third calling instruction). Used by the designer to lacate the instruction (file id of fourth calling instruction). Used by the designer to lacate the instruction (lineof fourth calling instruction). Not used. Not used. Not used. Not used. Not used. Not used. Not used.

318

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Originator = 502 MSDLSLTPP During a PPXX loading, TIME OUT expired because loader task on TDPC didn't answer an ack to the loader task on MPCC.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to locate the instruction (line of third calling instruction, if any). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any). not used not used not used not used not used not used not used

Originator = 507 MSDBASDL A timeout is expired while BSCA is waiting for a response by another entity
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used

A30808-X3247-K240-3-7619

319

Outputs OML:BSC

Base Station Controller

Originator = 510 MOSIWROMA An errorCollector function is called when Operating system Interworking audit task: 1- find saved_cmd_table entries busied too long. In this case a timeout expired message is sent to OMC/LMT system. 2- find aling info table entries busied too long because related End Alignment notification is not received. No fault responses are sent to OMC/LMT system.
aaaa = bbbb = Source code line Case 1: Error description depicted by designer: -CMD_TABLE_BUSIED_TOO_LONG. Occurred when some saved_cmd_table entries are busied beyond a specific fixed timeout (60 seconds) Case 2: Network Element mnemonic (MM_TRAU or MM_BTSM) Used only in case 2: Network Element instance number. Used only in case 2:Number of busyed structure table (Internal sw info) Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used

cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

= = = = = = = = = = = = =

Originator = 600 MSDBACTDA, 601 MSDBACTMT, 603 MSDBACTMA, 604 MSDBACTIA, 605 MSDBACTPA, 606 MSDBACTTA A timeout has expired during a communication between BSC Agent and processor controllers or between processor controllers and device handlers.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to lacate the instruction (file id of first calling instruction). Used by the designer to lacate the instruction (lineof first calling instruction). Used by the designer to lacate the instruction (file id of second calling instruction). Used by the designer to lacate the instruction (lineof second calling instruction). Used by the designer to lacate the instruction (file id of third calling instruction). Used by the designer to lacate the instruction (lineof third calling instruction). Used by the designer to lacate the instruction (file id of fourth calling instruction). Used by the designer to lacate the instruction (lineof fourth calling instruction). Not used. Not used. Not used. Not used. Not used. Not used. Not used.

320

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Originator = 625 MSDRIBSIU Timeout elapsed waiting the required file download end
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = line where the error is occurred Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used

Originator = 700 TOSSDATPL During a PPXX loading, TIME OUT expired while loader task on TDPC was waiting for a packet to load.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to locate the instruction (line of third calling instruction, if any). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any). not used not used not used not used not used not used not used

Originator = 2000 MDATABASE The error occurs if does not arrive the processor or task acknowledge message before the time out expired.
A30808-X3247-K240-3-7619 321

Outputs OML:BSC
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = =

Base Station Controller

line file identifier in which the error occurs not used not used not used not used not used not used not used not used not used not used not used not used not used Note. For the correspondence between the displayed numbers and the file identifiers, see ANNEX C.

Originator = 2001 MDBCADHDE 1)Timeout expired with a dba-server procedure still pending: procedure aborted and notification sent to relative device handler. 2) Time out expired with network element semaphore locked: semaphore is unlocked
aaaa = bbbb = cccc = source line absolute network element identifier (0-MAX_NBR_TRAU = TRAUN) (MAX_NBR_TRAU - MAX_NBR_TRAU+MAX_NBR_BTSM = BTSM+MAX_NBR_TRAU) 1 or 2 :allow to discriminate between case 1 or 2 if cccc = 1 if cccc = 2 dddd = requested semaphore state eeee = actual semaphore state ffff = high part of time-out time for semaphore gggg = low part of above time hhhh oooo = not used. mnemonic of the object target of procedure address[0] of the above object address[1] of the above object address[2] of the above object address[3] of the above object address[4] of the above object not used not used not used not used not used not used

dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

= = = = = = = = = = = =

322

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Originator = 2100 CDBMDBFH Time out expired while waiting a response from RC during an upload procedure
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Source line Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used

Originator = 2600 TDATABASE The error occurs if does not arrive the acknowledge message to Data Base task on TDPC from Device Handler task before the time out expired.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Source line code Source module identifier Not Used. Not Used. Not Used. Not Used. Not Used. Not Used. Not Used. Not Used. Not Used. Not Used. Not Used. Not Used. Not Used.

Originator = 3132 MSMSHPIHT This define is used to show that a timer associated to an executing command, has expired.
aaaa = Source line

A30808-X3247-K240-3-7619

323

Outputs OML:BSC
bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = Action Mnemonic of target object Unit address[0] Unit address[1] Unit address[2] Unit address[3] Mnemonic of object that has generated the timeout Unit address[0] Unit address[1] Unit address[2] Unit address[3] not used not used not used

Base Station Controller

Originator = 4451 MDHIXDCMC this error occurs when a timeout expired while the IXLT SW loading was in progress; the keep alive message from Load Server did not arrive to Device Handler.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = the line number of the source module the number of the IXLT card loading the state of the IXLT automata not used. not used. not used. not used. not used. not used. not used. not used. not used. not used. not used. not used.

Originator =

4501 MDHXXDCDE 4512 MDHXXLUDE

This error is generated in two cases.


324 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Case A) During a PPCU/PPXU Get Info command, GbIC processor (whose real time counters are requested) does not answer within 4 seconds. Case B)When an expected message from GPRS Device Handler has not been received in time.
aaaa = bbbb = cccc = dddd = eeee = ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = Case A) Error code. Case B) Number of PCU Case A) Source identifier. Case B) Counter of the times we have had to resend a message to GPRS Device Handler. Case A) Source line Case B) Old status of PCU Case A) Number of PPCU involved by Get Info command Case B) New status of PCU Case A) Counter of DH timers expirations. Case B) Event: Time out expired not used not used not used not used not used not used not used not used not used not used

Originator = 4508 MDHXXGSUT This error message is issued if a timer expires during message interface between DBA task for LAPD Create/Delete and PPLD DH or between DBA task handling FRL Create/Set/Delete and PPCU DH.
aaaa = bbbb = LAPD or FRL identifier Signal subtype in message from DBA task to PPxx DH: 1 = T15_LAPD_CREATE 2 = T15_LAPD_DELETE 7 = T15_FRL_CREATE 8 = T15_FRL_SET 9 = T15_FRL_DELETE Not used Not used Not used Not used Not used

cccc dddd eeee ffff gggg

= = = = =

A30808-X3247-K240-3-7619

325

Outputs OML:BSC
hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = Not used Not used Not used Not used Not used Not used Not used Not used

Base Station Controller

Originator = 4803 TDHLPSASC The device handler of the LAPD links performs a periodical audit on all existing LAPD instances; in case of the BTSM / TRAU device handler does not reply to a release or establish notification, this error is emitted.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = next lpdl to control time of last establishment or 0 when link is off mnemonic of associated network element number of associated network element not used not used not used not used not used not used not used not used not used not used not used

Originator = 5000 CPM_MPCC_ORIGINATOR The error occurs if there is no replay to a measurement result request from TDPC task.
aaaa bbbb cccc dddd eeee ffff = = = = = = not used not used not used not used not used not used

326

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = = = = = = not used not used not used not used not used not used not used not used not used

gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

Originator = 5000 CPM_MPCC_ORIGINATOR This error occurs if the schedule message from TDPC is in late or a timeout expires while MPCC is waiting for an answer from BTS device handler.
aaaa = bbbb = cccc = dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = Module that generates the error. Source code line of the module that generates the error. If (cccc<>0) this field indicates the schedule message late in seconds or it indicates scanner number. Internal use. Internal use. Internal use. Internal use. not used not used not used not used not used not used not used not used

Originator = 7001 TL3N7SCOC060, 7005 TL3N7SCOC020 This error is issued if the timers tconn or trel expire without a reply from the remote extreme.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii = = = = = = = = = Instance EDOS signal (see annex D for more details) Source C line where the error is occurred Process State not used not used not used not used not used

A30808-X3247-K240-3-7619

327

Outputs OML:BSC
jjjj kkkk llll mmmm nnnn oooo = = = = = = not used not used not used not used not used not used

Base Station Controller

Originator = 7100 TL3RDALL This error is issued if the timer T3 or T4 concerning respectively SUSPEND and RESUME procedures expired for SUSPEND/RESUME RETRIES (3) consecutive times for the same MS.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Process Identifier (see annex D for more details) Process Instance Process State (0x14 for SUSPEND, 0x28 for RESUME) Not Used Process Source Line Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used

Originator = 7205 PKPMUTBUTM, 7207 PKPMDTBDTM. This error is issued if the timer T3191, T3195 or T3169 expired.
aaaa = bbbb = cccc = Process State. Process Instance. EDOS Message Code. Timers are: 0x22: T3191 0x24: T3195 0x21: T3169 ProcessSource Line. Procedure Module Originator. Procedure Module Line. Not used. VQ where the TBF is (UL) TLLI TLLI BVCI where the TBF is established.

dddd eeee ffff gggg hhhh iiii jjjj kkkk

= = = = = = = =

328

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = N3101 counter (for UL) or N3103 counter (for DL). N3103 counter (for UL) or N3105 counter (for DL). Not used. PPCU/PPXU involved (1st byte) and Process Sending Message (2nd byte).

llll mmmm nnnn oooo

Originator = 7208 PKTSPRMPCH This is an error issued if no response arrives to Packet Resource Manager either from TDPC (when a new PDCH is required) or from AbIC (when the alignment of a new PDT is required).
aaaa = bbbb = cccc = dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = Process State. Process Instance. EDOS Message Code (0x00 or 0x1B: No response from TDPC; 0x17: No response from AbIC). ProcessSource Line. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. PPCU/PPXU involved (1st byte) and Process Sending Message (2nd byte).

Originator = 9000 MDGDMPIPR This define is used to show that a timer associated to a start test in progress has expired.So Diagnostic Manager releases the entry and discharges the command.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn = = = = = = = = = = = = = = <test_id.me_mnemonic>(logical object under test) <test_id.me_address[0]> <test_id.me_address[1]> <test_id.me_address[2]> <test_id.me_address[3]> <me_id.me_mnemonic>(real object under test) <me_id.me_address[0]> <me_id.me_address[1]> <me_id.me_address[2]> <me_id.me_address[3]> <job number> <phases to be executed> <phases executed> <destination>

A30808-X3247-K240-3-7619

329

Outputs OML:BSC
oooo = not used

Base Station Controller

<Test_id>is a logical value (MM_TEST-x)used by Diagnostic Manager to identify the running test. <me_id>is the object requested by the operator with the start_test command.

Originator = 10100 MQ3US A timeout related to the confirmation of a previously sent message is expired
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = designer oriented: an integher identifying the module where timout expired designer oriented: the line (hex value) within the module where timout expired not used not used not used not used not used not used designer oriented : it identifies the message type not used designer oriented : it identifies the destination mailbox of the message not used not used not used not used

Originator = 10103 MBACW A timeout related to a pending back_end operation expires


aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = designer oriented: an integher identifying the module where timout expired designer oriented: the line (hex value) within the module where timout expired not used not used not used not used not used not used not used not used not used not used not used not used not used

330

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Originator = 10104 MBAMW A timeout related to a pending back_end operation expires during a function of MBAEH subsystem called by originating subsystem of BSS Agent area
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = designer oriented: an integher identifying the module where timout expired designer oriented: the line (hex value) within the module where timout expired not used not used not used not used not used not used not used not used not used not used not used not used not used

Originator = 10106 MBAMA A MBAMA subsystem of BSS Agent area timeout expires
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = designer oriented: an integher identifying the module where timout expired designer oriented: the line (hex value) within the module where timout expired designer oriented: the BSC objects (0) or the equipment type (1=BTSE, 2=TRAU) designer oriented: the equipment number (significant only if previous is 1 or 2) designer oriented: the tymer type flag (1=NORMAL STATE, 2=WAIT START AUDIT STATE, 3=WAIT SNAPSHOT STATE, 4=WAIT TO REQUEST SNAPSHOT STATE) not used not used not used not used not used not used not used not used not used not used

A30808-X3247-K240-3-7619

331

Outputs OML:BSC

Base Station Controller

Originator = 10107 MBAAW A MBAAW subsystem of BSS Agent area timeout expires
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = designer oriented: an integher identifying the module where timout expired designer oriented: the line (hex value) within the module where timout expired not used not used not used not used not used not used not used not used not used not used not used not used not used

Originator = 10108 MQ3CB A timer related to the CB-command/CB-response (or the spontaneous event) expired.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = (developer oriented) source module (developer oriented) number of source module line (developer oriented) (developer oriented) not used not used not used not used not used not used not used not used not used not used not used

332

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

47 VARIABLE OUT OF RANGE


FAILURE EVENT REPORT: NAME = Probable cause = Specific Problems = Event Type = Event Time = Severity = Trend Indication = Notification Identifier = Correlated Notification Identifier = Related MO = Proposed Repair Actions = Additional Text = Originator = Additional Words =
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo <R.T.D.>

<R.T.D.> <R.T.D.> Variable Out Of Range <see legend> <see legend> <R.T.D.> <see legend> <R.T.D.> <R.T.D.> <displayed only during Alarm Alignment> <R.T.D.> <R.T.D.> <see legend> <R.T.D.> <see legend>

Software Version =

Legend:

Specific Problems = 022 VARIABLE OUT OF RANGE WARNING

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 124 MOSSDNDDL0 A variable used by the BTSE download task contains an out of range value.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll = = = = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to locate the instruction (line of third calling instruction, if any). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any). not used. not used. not used. not used.

A30808-X3247-K240-3-7619

333

Outputs OML:BSC
mmmm = nnnn = oooo = not used. not used. not used.

Base Station Controller

Originator = 125 MOSSDNDDL1 A variable used by the TRAU download task contains an out of range value.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to locate the instruction (line of third calling instruction, if any). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any). not used. not used. not used. not used. not used. not used. not used.

Originator = 126 MOSSDNSBL A variable used by the BTSE alignment task contains an out of range value.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to locate the instruction (line of third calling instruction, if any). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any). NE whose alignment has failed. Failure cause. not used. not used. not used. not used. not used.

334

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Originator = 127 MOSSDNSTL A variable used by the TRAU alignment task contains an out of range value.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to locate the instruction (line of third calling instruction, if any). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any). NE whose alignment has failed. Failure cause. not used. not used. not used. not used. not used.

Originator = 128 MOSSDNSBC A variable used by the BTSE activation procedure on the BSC contains an out of range value.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to locate the instruction (line of third calling instruction, if any). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any). Not used. Not used. Not used. Not used. Not used. Not used. Not used.

A30808-X3247-K240-3-7619

335

Outputs OML:BSC

Base Station Controller

Originator = 129 MOSSDNSTC A variable used by the TRAU activation procedure on the BSC contains an out of range value.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to locate the instruction (line of third calling instruction, if any). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any). Not used. Not used. Not used. Not used. Not used. Not used. Not used.

Originator = 624 MSDRIBSMA Internal flag used to identify current status of the BSC Remote Inventory task has been detected outside valid range.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = line where the error is occurred current state Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

Originator = 2000 MDATABASE The error occurs if one parameter is not in the right range. Note. For the corrispondence between the displayed numbers and the file identifiers, see
336 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

ANNEX C.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = line file identifier not used not used not used not used not used not used not used not used not used not used not used not used not used

Originator = 2100 CDBMDBFH A variable used by the Upload task contains an out of range value
aaaa = bbbb = Source C line Depends on the source C line this field could be: 1)Not used 2)Used by the designer to indicate the activity current value 3)Used by the designer to indicate the state current value 4)Used by the designer to indicate the event current value 5)Used by the designer to indicate the file_subtype definition value Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used

cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

= = = = = = = = = = = = =

Originator = 2222 CDBMDHSA This error is issued when the function fdba objToBscan returns a value different from
A30808-X3247-K240-3-7619 337

Outputs OML:BSC

Base Station Controller

SUCCESSFULL or when the local variable for the current state is out of range.
aaaa = bbbb = Source C line Depends on the source C line this field could be: 1) Used by the designer to indicate the return value of fdbca_objToBscan 2) Used by the designer to indicate the current state Depends on the source C line this field could be: 1) Used by the designer to indicate the mnemonic of current object SCA/RFLOOP 2) Not used Depends on the source C line this field could be: 1) Used by the designer to indicate the address[0] of current object SCA/RFLOOP 2) Not used Depends on the source C line this field could be: 1) Used by the designer to indicate the address[1] of current object SCA/RFLOOP 2) Not used Depends on the source C line this field could be: 1) Used by the designer to indicate the address[2] of current object SCA/RFLOOP 2) Not used Depends on the source C line this field could be: 1) Used by the designer to indicate the address[3] of current object SCA/RFLOOP 2) Not used Not used Not used Not used Not used Not used Not used Not used Not used

cccc =

dddd =

eeee =

ffff =

gggg =

hhhh iiii jjjj kkkk llll mmmm nnnn oooo

= = = = = = = =

Originator = 2600 TDATABASE A variable contains an out of range value


aaaa = bbbb = Source C line Source module that generates the error. Possible values are: 0x0005 for DBLACEBS_FILE 0x0007 for DBLACECH_FILE 0x001D for DBLAUTFC_FILE Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used

cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

= = = = = = = = = = = = =

338

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Originator = 3000 MSMARECCO, 3500 TSMARECCO Error collector on MPCC or TDPC has verified that the error received is managed with thresholds, but it was not able to find the counter of the threshold examined in the related table. Error collector cannot continue to process this fault message.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Originator of error that caused this warning. Source code line number of error collector module. Error identifier of message that caused this warning. Not used. Not used. Object mnemonic identifier of message that caused this warning. Object first address of message that caused this warning. Object second address of message that caused this warning. Object third address of message that caused this warning. Object fourth address of message that caused this warning. Not used. Not used. Not used. Not used. Not used.

Originator = 4980 NDHPDDCMA This error is issued if a command coming from PPXX DH on MPCC is not contained inside a "PPXU Agent" internal list.
aaaa = bbbb = cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = Source code line Code of MPCC message (Force OOS Idle = 0x31, Force In Service = 0x32, Give Status = 0x33, Restart = 0x40, Get Info = 0x70, Execute Diagnostic Test = 0x21) Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used

A30808-X3247-K240-3-7619

339

Outputs OML:BSC

Base Station Controller

Originator = 4990 YDHPDDCMA This error is issued if a command coming from PPXX DH on MPCC is not contained inside a "PPXL Agent" internal list.
aaaa = bbbb = cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = Source code line Code of MPCC message (Force OOS Idle = 0x31, Force In Service = 0x32, Give Status = 0x33, Restart = 0x40, Get Info = 0x70, Execute Diagnostic Test = 0x21) Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used

Originator = 5100 CPM_PCUC_ORIGINATOR The error occurs if a variable is not in the right range. All related additional info are developer oriented and useful for debugging activity
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Source module that generates the error; Source code line of the module that generates the error. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use.

340

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Originator = 5500 CPM_TDPC_ORIGINATOR The error occurs if a variable is not in the right range. All related additional info are developer oriented and useful for debugging activity
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Source module that generates the error; Source code line of the module that generates the error. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use.

Originator = 9004 MDGDMPIIR This error is issued normally at the reception of a message not forseen by the test managment main task. Besides, during a reception and elaboration process of a STOP TEST request, the error is provided for wrong value specification in the input message. Valid value for 'bbbb' field are "TEST NOT IN", "STOP DONE" or "STOP UNDONE". In the last case it has been received a wrong value.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = <source line when the error has occured> <value of istance of test> not used not used not used not used not used not used not used not used not used not used not used not used not used

A30808-X3247-K240-3-7619

341

Outputs OML:BSC

Base Station Controller

Originator = 10108 MQ3CB An invalid state or event or entry has been detected
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = (developer oriented)source module (developer oriented) number of source module line (developer oriented) state, event and entry not used not used not used not used not used not used not used not used not used not used not used not used

342

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

49 COOLING SYSTEM FAILURE


FAILURE EVENT REPORT: NAME = Probable cause = Specific Problems = Event Type = Event Time = Severity = Trend Indication = Notification Identifier = Correlated Notification Identifier = Related MO = Proposed Repair Actions = Additional Text = Originator = Additional Words =
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo <R.T.D.>

<R.T.D.> <R.T.D.> Cooling System Failure <see legend> <see legend> <R.T.D.> <see legend> <R.T.D.> <R.T.D.> <displayed only during Alarm Alignment> <R.T.D.> <R.T.D.> <see legend> <R.T.D.> <see legend>

Software Version =

Legend:

Specific Problems = 125 AIR CONDITIONING EQUIPMENT ALARM

Event Type = ENVIRONMENTAL FAILURE EVENT Severity = MAJOR Proposed Repair Actions = 6 SEE THE FORESEEN OPERATING COMPANY REPAIR ACTION

Originator = 4001 MDHACENSA The air conditioning system does not work.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll = = = = = = = = = = = = Developer reserved: code line number where error is emitted Error originator where error was detected Reports the Sense Point number to which the temperature sensor is connected (from 0 to 4). Reports the number of seconds to consider the alarm as true (i.e. the alarm must persist the reported number of seconds to take it into account). Reports the current state of all Sense Points. Reports if the alarm was detecetd on the active copy of Mpcc (1if TRUE , 0 if FALSE) Reports if the alarm was detecetd on the standby copy of Mpcc (1if TRUE , 0 if FALSE). Reports the number of the active Mpcc. not used not used not used not used

A30808-X3247-K240-3-7619

343

Outputs OML:BSC
mmmm = nnnn = oooo = not used not used not used

Base Station Controller

344

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

50 EXTERNAL EQUIPMENT FAILURE


FAILURE EVENT REPORT: NAME = Probable cause = Specific Problems = Event Type = Event Time = Severity = Trend Indication = Notification Identifier = Correlated Notification Identifier = Related MO = Proposed Repair Actions = Additional Text = Originator = Additional Words =
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo <R.T.D.>

<R.T.D.> <R.T.D.> External Equipment Failure <see legend> <see legend> <R.T.D.> <see legend> <R.T.D.> <R.T.D.> <displayed only during Alarm Alignment> <R.T.D.> <R.T.D.> <see legend> <R.T.D.> <see legend>

Software Version =

Legend:

Specific Problems = 134 OPERATOR DEFINED ALARM

Event Type = ENVIRONMENTAL FAILURE EVENT Severity = MAJOR Proposed Repair Actions = 6 SEE THE FORESEEN OPERATING COMPANY REPAIR ACTION

Originator = 4001 MDHACENSA An operator defined problem has been detected in the BSC system environmental alarm.
aaaa = bbbb = cccc = Developer reserved: code line number where error is emitted Error originator where error was detected Reports the Sense Point number to which the main power supply sensor is connected (from 0 to 4). Reports the number of seconds to consider the alarm as true (i.e. the alarm must persist the reported number of seconds to take it into account). Reports the current state of all Sense Points. Reports if the alarm was detecetd on the active copy of Mpcc (1if TRUE , 0 if FALSE) Reports if the alarm was detecetd on the standby copy of Mpcc (1if TRUE , 0 if FALSE). Reports the number of the active Mpcc. Not used. Not used. Not used.

dddd = eeee ffff gggg hhhh iiii jjjj kkkk = = = = = = =

A30808-X3247-K240-3-7619

345

Outputs OML:BSC
llll mmmm nnnn oooo = = = = Not used. Not used. Not used. Not used.

Base Station Controller

346

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

51 EXTERNAL POWER SUPPLY FAILURE


FAILURE EVENT REPORT: NAME = Probable cause = Specific Problems = Event Type = Event Time = Severity = Trend Indication = Notification Identifier = Correlated Notification Identifier = Related MO = Proposed Repair Actions = Additional Text = Originator = Additional Words =
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo <R.T.D.>

<R.T.D.> <R.T.D.> External Power Supply Failure <see legend> <see legend> <R.T.D.> <see legend> <R.T.D.> <R.T.D.> <displayed only during Alarm Alignment> <R.T.D.> <R.T.D.> <see legend> <R.T.D.> <see legend>

Software Version =

Legend:

Specific Problems = 133 MAIN POWER SUPPLY ALARM

Event Type = ENVIRONMENTAL FAILURE EVENT Severity = MAJOR Proposed Repair Actions = 6 SEE THE FORESEEN OPERATING COMPANY REPAIR ACTION

Originator = 4001 MDHACENSA A problem has been detected in the main power supply (the power supply which feeds the BSC).
aaaa = bbbb = cccc = Developer reserved: code line number where error is emitted Error originator where error was detected Reports the Sense Point number to which the main power supply sensor is connected (from 0 to 4). Reports the number of seconds to consider the alarm as true (i.e. the alarm must persist the reported number of seconds to take it into account). Reports the current state of all Sense Points. Reports if the alarm was detecetd on the active copy of Mpcc (1if TRUE , 0 if FALSE) Reports if the alarm was detecetd on the standby copy of Mpcc (1if TRUE , 0 if FALSE). Reports the number of the active Mpcc. Not used. Not used.

dddd = eeee ffff gggg hhhh iiii jjjj = = = = = =

A30808-X3247-K240-3-7619

347

Outputs OML:BSC
kkkk llll mmmm nnnn oooo = = = = = Not used. Not used. Not used. Not used. Not used.

Base Station Controller

348

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

52 EXTERNAL TRANSMISSION DEVICE FAILURE


FAILURE EVENT REPORT: NAME = Probable cause = Specific Problems = Event Type = Event Time = Severity = Trend Indication = Notification Identifier = Correlated Notification Identifier = Related MO = Proposed Repair Actions = Additional Text = Originator = Additional Words =
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo <R.T.D.>

<R.T.D.> <R.T.D.> External Transmission Device Failure <see legend> <see legend> <R.T.D.> <see legend> <R.T.D.> <R.T.D.> <displayed only during Alarm Alignment> <R.T.D.> <R.T.D.> <see legend> <R.T.D.> <see legend>

Software Version =

Legend:

Specific Problems = 130 TRANSMISSION EQUIPMENT ALARM

Event Type = ENVIRONMENTAL FAILURE EVENT Severity = MAJOR Proposed Repair Actions = 6 SEE THE FORESEEN OPERATING COMPANY REPAIR ACTION

Originator = 4001 MDHACENSA A problem has been detected in the transmission equipment.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll = = = = = = = = = = = = Developer reserved: code line number where error is emitted Error originator where error was detected Reports the Sense Point number to which the temperature sensor is connected (from 0 to 4). Reports the number of seconds to consider the alarm as true (i.e. the alarm must persist the reported number of seconds to take it into account). Reports the current state of all Sense Points. Reports if the alarm was detecetd on the active copy of Mpcc (1if TRUE , 0 if FALSE) Reports if the alarm was detecetd on the standby copy of Mpcc (1if TRUE , 0 if FALSE). Reports the number of the active Mpcc. not used. not used. not used. not used.

A30808-X3247-K240-3-7619

349

Outputs OML:BSC
mmmm = nnnn = oooo = not used. not used. not used.

Base Station Controller

350

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

56 INTRUSION DETECTED
FAILURE EVENT REPORT: NAME = Probable cause = Specific Problems = Event Type = Event Time = Severity = Trend Indication = Notification Identifier = Correlated Notification Identifier = Related MO = Proposed Repair Actions = Additional Text = Originator = Additional Words =
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo <R.T.D.>

<R.T.D.> <R.T.D.> Intrusion Detected <see legend> <see legend> <R.T.D.> <see legend> <R.T.D.> <R.T.D.> <displayed only during Alarm Alignment> <R.T.D.> <R.T.D.> <see legend> <R.T.D.> <see legend>

Software Version =

Legend:

Specific Problems = 129 INTRUSION DETECTION ALARM

Event Type = ENVIRONMENTAL FAILURE EVENT Severity = MAJOR Proposed Repair Actions = 6 SEE THE FORESEEN OPERATING COMPANY REPAIR ACTION

Originator = 4001 MDHACENSA An intrusion in the environment where the system is located has been detected.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll = = = = = = = = = = = = Developer reserved: code line number where error is emitted Error originator where error was detected Reports the Sense Point number to which the temperature sensor is connected (from 0 to 4). Reports the number of seconds to consider the alarm as true (i.e. the alarm must persist the reported number of seconds to take it into account). Reports the current state of all Sense Points. Reports if the alarm was detecetd on the active copy of Mpcc (1if TRUE , 0 if FALSE) Reports if the alarm was detecetd on the standby copy of Mpcc (1if TRUE , 0 if FALSE). Reports the number of the active Mpcc. not used. not used. not used. not used.

A30808-X3247-K240-3-7619

351

Outputs OML:BSC
mmmm = nnnn = oooo = not used. not used. not used.

Base Station Controller

352

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

59 SMOKE DETECTED
FAILURE EVENT REPORT: NAME = Probable cause = Specific Problems = Event Type = Event Time = Severity = Trend Indication = Notification Identifier = Correlated Notification Identifier = Related MO = Proposed Repair Actions = Additional Text = Originator = Additional Words =
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo <R.T.D.>

<R.T.D.> <R.T.D.> Smoke Detected <see legend> <see legend> <R.T.D.> <see legend> <R.T.D.> <R.T.D.> <displayed only during Alarm Alignment> <R.T.D.> <R.T.D.> <see legend> <R.T.D.> <see legend>

Software Version =

Legend:

Specific Problems = 128 SMOKE DETECTION ALARM

Event Type = ENVIRONMENTAL FAILURE EVENT Severity = MAJOR Proposed Repair Actions = 6 SEE THE FORESEEN OPERATING COMPANY REPAIR ACTION

Originator = 4001 MDHACENSA Smoke in the environment where the system is located has been detected.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll = = = = = = = = = = = = Developer reserved: code line number where error is emitted Error originator where error was detected Reports the Sense Point number to which the temperature sensor is connected (from 0 to 4). Reports the number of seconds to consider the alarm as true (i.e. the alarm must persist the reported number of seconds to take it into account). Reports the current state of all Sense Points. Reports if the alarm was detecetd on the active copy of Mpcc (1if TRUE , 0 if FALSE) Reports if the alarm was detecetd on the standby copy of Mpcc (1if TRUE , 0 if FALSE). Reports the number of the active Mpcc. not used. not used. not used. not used.

A30808-X3247-K240-3-7619

353

Outputs OML:BSC
mmmm = nnnn = oooo = not used. not used. not used.

Base Station Controller

354

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

64 SYSTEM RESOURCES OVERLOAD


FAILURE EVENT REPORT: NAME = Probable cause = Specific Problems = Event Type = Event Time = Severity = Trend Indication = Notification Identifier = Correlated Notification Identifier = Related MO = Proposed Repair Actions = Additional Text = Originator = Additional Words =
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo <R.T.D.>

<R.T.D.> <R.T.D.> System Resources Overload <see legend> <see legend> <R.T.D.> <see legend> <R.T.D.> <R.T.D.> <displayed only during Alarm Alignment> <R.T.D.> <R.T.D.> <see legend> <R.T.D.> <see legend>

Software Version =

Legend:

##StartSpecProbl##
Specific Problems = 132 CTR OVERLOAD

Event Type = QUALITY OF SERVICE FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 5002 CPM_CTR ORIGINATOR This message is issued by CTR Tracing task if there are problems before a request of tracing or if there are informations about the tracement itself. All related additional info are developer oriented and useful for debugging activity
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii = = = = = = = = = Module that generates the error. Source code line of the module that generates the error. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use.

A30808-X3247-K240-3-7619

355

Outputs OML:BSC
jjjj kkkk llll mmmm nnnn oooo = = = = = = Internal use. Internal use. Internal use. Internal use. Internal use. Internal use.

Base Station Controller

##StartSpecProbl##
Specific Problems = 188 MSC OVERLOAD DETECTED

Event Type = QUALITY OF SERVICE FAILURE EVENT Severity = CRITICAL Proposed Repair Actions = 1 NO ACTION

Originator = 7100 TL3RDALL Traffic overload detected


aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used

##StartSpecProbl##
Specific Problems = 223 AP TRACE TDPC OVERLOAD

Event Type = QUALITY OF SERVICE FAILURE EVENT Severity = MAJOR Proposed Repair Actions = 1 NO ACTION

Originator = 7100 TL3RDALL

356

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

TDPC Overload started: Trace Control Object is going disabled.


aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Process Identifier (see annex D for more details) Process Instance Process State Not Used Process Source Line Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used

##StartSpecProbl##
Specific Problems = 243 BTS OVERLOAD DETECTED

Event Type = QUALITY OF SERVICE FAILURE EVENT Severity = MINOR Proposed Repair Actions = 1 NO ACTION

Originator = 7100 TL3RDALL Traffic overload detected


aaaa = BTS overload cause 06 AGCH CONGESTION 07 CCCH CONGESTION 08 ACCH CONGESTION Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used

bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

= = = = = = = = = = = = = =

A30808-X3247-K240-3-7619

357

Outputs OML:BSC

Base Station Controller

Specific Problems = 249 BSC OVERLOAD DETECTED

Event Type = QUALITY OF SERVICE FAILURE EVENT Severity = CRITICAL Proposed Repair Actions = 1 NO ACTION

Originator = 7100 TL3RDALL Traffic overload detected


aaaa = In case of NAME equal to BSC: BSC overload cause 01 TDPC realtime consuming over configured threshold 02 call processing register type 1 usage over 95% 03 call processing register type 2 usage over 95% 04 call processing register type 3 usage over 95% 05 ss7l congestion 09 TDPC os dynamic memory congestion In case of NAME equal to PCU (PCUC realtime consuming over fixed threshold): Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used

bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

= = = = = = = = = = = = = =

358

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

65 BROADCAST CHANNEL FAILURE


FAILURE EVENT REPORT: NAME = Probable cause = Specific Problems = Event Type = Event Time = Severity = Trend Indication = Notification Identifier = Correlated Notification Identifier = Related MO = Proposed Repair Actions = Additional Text = Originator = Additional Words =
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo <R.T.D.>

<R.T.D.> <R.T.D.> Broadcast Channel Failure <see legend> <see legend> <R.T.D.> <see legend> <R.T.D.> <R.T.D.> <displayed only during Alarm Alignment> <R.T.D.> <R.T.D.> <see legend> <R.T.D.> <see legend>

Software Version =

Legend:

##StartSpecProbl##
Specific Problems = 113 BTS NO CBCH AVAILABLE

Event Type = QUALITY OF SERVICE FAILURE EVENT Severity = CRITICAL Proposed Repair Actions = 1 NO ACTION

Originator = 4700 TDHBFCFMN This notification occurs when the BTSM DH detects the loss of the COMMON BROADCAST channel.
aaaa bbbb cccc dddd eeee = = = = = module line when the Error Collector call is. BTSM number BTS relative number BTSM software release High BAR condition (DHBFI.H): BAR_NO_BTSM 0x1 btsm disabled or locked BAR_NO_BTS 0x2 bts disabled or locked BAR_NO_TRX 0x4 no one trx enabled-unlocked BAR_NO_BCCH 0x8 no bcch currently available BAR_FAILED_BCCH 0x10 bcch trx locked or disabled dep abis BAR_BCCH_DSBL 0x20 keep barred the cell as long as bcch is not enable BAR_NO_SDCCH 0x40 no sdcch currently available

A30808-X3247-K240-3-7619

359

Outputs OML:BSC
BAR_FAILED_SDCCH 0x80 BAR_NO_TCH 0x100 BAR_TCH_DSBL 0x200 BAR_FAILED_HOP 0x400 BAR_FAILED_CBCH 0x800 BAR_STRTM 0x1000 BAR_ENABLE_HOP 0x2000 BAR_BCCH_FREQ 0x4000 Low BAR condition (DHBFI.H): BAR_NO_BTSM 0x1 BAR_NO_BTS 0x2 BAR_NO_TRX 0x4 BAR_NO_BCCH 0x8 BAR_FAILED_BCCH 0x10 BAR_BCCH_DSBL 0x20 BAR_NO_SDCCH 0x40 BAR_FAILED_SDCCH 0x80 BAR_NO_TCH 0x100 BAR_TCH_DSBL 0x200 BAR_FAILED_HOP 0x400 BAR_FAILED_CBCH 0x800 BAR_STRTM 0x1000 BAR_ENABLE_HOP 0x2000 BAR_BCCH_FREQ 0x4000 Internal high error code: EC_BCCH_OUTAGE 0x1 EC_NO_BCCH 0x2 EC_FAILED_HOP 0x4 EC_NO_TCH 0x8 EC_NO_SDCCH 0x10 EC_NO_CBCH 0x20 EC_DEGRADED_BARR 0x40 EC_DEGRADED_DIV 0x80 EC_CRIT_THR 0x400 EC_MAJOR_THR 0x200 EC_MINOR_THR 0x100 EC_RESTART_HOP 0x800 EC_BCCH_FREQ 0x1000 Internal low error code: EC_BCCH_OUTAGE 0x1 EC_NO_BCCH 0x2 EC_FAILED_HOP 0x4 EC_NO_TCH 0x8 EC_NO_SDCCH 0x10 EC_NO_CBCH 0x20 EC_DEGRADED_BARR 0x40 EC_DEGRADED_DIV 0x80 EC_CRIT_THR 0x400 EC_MAJOR_THR 0x200 EC_MINOR_THR 0x100 EC_RESTART_HOP 0x800 EC_BCCH_FREQ 0x1000 BCCH TRX absolute number SCBCH TRX absolute number number of SDCCH channels number of TCH channels IsHopp status value (TRUE/FALSE) AbisHopp value (TRUE/FALSE) Not Used

Base Station Controller

last sdcch trx locked or disabled dep abis no traffic channel available keep barred the cell at least a channel is enabled hopping trx locked of disable dep abis cbch trx locked or disabled dep abis starting time procedure evolving restart of hopping procedure bcch frequency change procedure btsm disabled or locked bts disabled or locked no one trx enabled-unlocked no bcch currently available bcch trx locked or disabled dep abis keep barred the cell as long as bcch is not enable no sdcch currently available last sdcch trx locked or disabled dep abis no traffic channel available keep barred the cell at least a channel is enabled hopping trx locked of disable dep abis cbch trx locked or disabled dep abis starting time procedure evolving restart of hopping procedure bcch frequency change procedure

ffff =

gggg =

bts degraded for bar causes; bts degraded for diversity

hhhh =

bts degraded for bar causes; bts degraded for diversity

iiii jjjj kkkk llll mmmm nnnn oooo

= = = = = = =

360

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Specific Problems = 167 BCCH OUTAGE

Event Type = COMMUNICATION FAILURE EVENT Severity = CRITICAL Proposed Repair Actions = 1 NO ACTION

Originator = 4916 TDHBFCFMN This error occurs when there is no possibility to recover the BCCH because no TRX is available. Only in this situation the cell gets DISABLED.
aaaa = bbbb = cccc = Line of the module where the Error Collector call is. Btsm number. Bar condition: DHBFI.H ==> BAR_NO_BTSM = 0x1, btsm disabled or locked; BAR_NO_BTS = 0x2, bts disabled or locked; BAR_NO_TRX = 0x4, no one trx enabled unlocked; BAR_NO_BCCH = 0x8, no bcch currently available; BAR_FAILED_BCCH = 0x10, bcch trx locked or disabled dep abis BAR_BCCH_DSBL = 0x20, keep barred the cell as long as bcch is not enable; BAR_NO_SDCCH = 0x40, no sdcch currently available; BAR_FAILED_SDCCH = 0x80, last sdcch trx locked or disabled dep abis; BAR_NO_TCH = 0x100, no traffic channel available; BAR_TCH_DSBL = 0x200, keep barred the cell at least a channel is enabled; BAR_FAILED_HOP = 0x400, hopping trx locked of disable dep abis BAR_FAILED_CBCH = 0x800, cbch trx locked or disabled dep abis BAR_STRTM = 0x1000, starting time procedure evolving; BAR_RECFILT = (BAR_FAILED_BCCH + BAR_FAILED_SDCCH + BAR_FAILED_CBCH + BAR_FAILED_HOP), bar conditions related to reconfigurations; BAR_SUPER = (BAR_NO_BTSM + BAR_NO_BTS), superior bar condition that inhibit any reconfiguration; Internal error code: EC_BCCH_OUTAGE 0x1, BTS_BCCH_OUTAGE: EC_NO_BCCH 0x2, BTS_NO_BCCH_AVAILABLE; EC_FAILED_HOP 0x4, BTS_FAILED_HOPPING_SYSTEM: EC_NO_TCH 0x8, BTS_NO_TCH_AVAILABLE: EC_NO_SDCCH 0x10, BTS_NO_SDCCH_AVAILABLE: EC_NO_CBCH 0x20, BTS_NO_CBCH_AVAILABLE: EC_DEGRADED_BARR 0x40, BTS DGRADED FOR BAR CAUSES: EC_DEGRADED_DIV 0x80, BTS DEGRADED FOR DIVERSITY CAUSES: EC_DEGRADED (EC_DEGRADED_BARR + EC_DEGRADED_DIV): EC_FAILURES (EC_NO_BCCH | EC_NO_TCH): This three last value is related to a BTS availability thresholds depending on the available channels: EC_CRIT_THR 0x100, CRITICAL_THRESHOLD: EC_MAJOR_THR 0x200, MAJOR_THRESHOLD: EC_MINOR_THR 0x400, MINOR_THRESHOLD. Bcch Trx absolute number. Scbch Trx absolute number. Bts relative number. not used not used not used not used not used not used not used not used

dddd =

eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

= = = = = = = = = = =

A30808-X3247-K240-3-7619

361

Outputs OML:BSC

Base Station Controller

67 INVALID MESSAGE RECEIVED


FAILURE EVENT REPORT: NAME = Probable cause = Specific Problems = Event Type = Event Time = Severity = Trend Indication = Notification Identifier = Correlated Notification Identifier = Related MO = Proposed Repair Actions = Additional Text = Originator = Additional Words =
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo <R.T.D.>

<R.T.D.> <R.T.D.> Invalid Message Received <see legend> <see legend> <R.T.D.> <see legend> <R.T.D.> <R.T.D.> <displayed only during Alarm Alignment> <R.T.D.> <R.T.D.> <see legend> <R.T.D.> <see legend>

Software Version =

Legend:

##StartSpecProbl##
Specific Problems = 108 INVALID MESSAGE FROM ABIS/ASUB

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 812 TOSICIOIT It is no possible to receive a message from ABIS ASUB interface, because some field of the RTE++ or NM headers is wrong: it is no possibile to calculate the message destination.
aaaa = 0x01 INVALID SOURCE SYS 0x02 INVALID SAPI 0x03 INVALID MESSAGE TYPE 0x04 INVALID OBJECT CLASS 0x05 INVALID LAPD ADDRESS Current value of the variable source_sys Current value of the variable dest_sys Current value of the variable sapi_no Current value of the variable btsm_no /trau_no/bts_no/trxidx Current value of the variable card_no Current value of the variable d_channel_no/timeslot_no_hc Current value of the variable tei_no

bbbb cccc dddd eeee ffff gggg hhhh

= = = = = = =

362

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = = = = Current value of the variable message_type Current value of the variable object_class Current value of the variable object_inst_0 Current value of the variable object_inst_1 Current value of the variable object_inst_2 Curennt value of error value of db_get_network_element else it is 0 0x01 REGULAR_CAPACITY_CONF 0X02 HIGH_CAPACITY_CONF

iiii jjjj kkkk llll mmmm nnnn oooo

##StartSpecProbl##
Specific Problems = 109 INVALID MESSAGE TO ABIS/ASUB

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 813 TOSICIOOT It is no possible to send a message to ABIS ASUB interface, because some field of the RTE++ or NM headers is wrong: it is no possibile to calculate the message destination.
aaaa = bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = 0x03 INVALID MESSAGE TYPE 0x06 INVALID NETWORK ELEMENT Current value of the variable source_sys Current value of the variable dest_sys Current value of the variable sapi_no Current value of the variable btsm_no /trau_no/bts_no/trxidx Current value of the variable card_no Current value of the variable d_channel Current value of the variable tei_no Current value of the variable message_type Current value of the variable object_class Current value of the variable object_inst_0 Current value of the variable object_inst_1 Current value of the variable object_inst_2 Curennt value of error value of db_get_lapd_address else it is 0 0x01 REGULAR_CAPACITY_CONF 0X02 HIGH_CAPACITY_CONF

##StartSpecProbl##
Specific Problems = 263 INVALID MESSAGE FROM PCUC

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

A30808-X3247-K240-3-7619

363

Outputs OML:BSC

Base Station Controller

Originator = 812 TOSICIOIT Some fields of the RTE+ message are wrong, so it is not possible to send a message to a task, after the DUAM reading.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = 0x0b INVALID_ROUTING Current value of the variable source_sys Current value of the variable dest_sys Current value of the variable source_mbx Current value of the variable dest_mbx Current value of the variable signal_type Current value of the variable signal_subtype Current value of the variable rtn_err Current value of the variable channel_no=0 0x01 REGULAR_CAPACITY_CONF 0X02 HIGH_CAPACITY_CONF not used not used not used not used not used

##StartSpecProbl##
Specific Problems = 265 INVALID READING MESSAGE

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 951 UOSICIOIT

364

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

It is not possible to send a message to a task, because some fileds of RTE+ message header are wrong: it is not possible to send a message to PCUC task or out of PCUC system.
aaaa = bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = 0x0c INVALID ROUTING FROM GbIC 0x0d INVALID ROUTING FROM TDPC Current value of the variable source_sys Current value of the variable dest_sys Current value of the variable source_mbx Current value of the variable dest_mbx Current value of the variable signal_type Current value of the variable signal_subtype Current value of the variable rtn_error not used not used not used not used not used not used not used

Originator = 980 YOSICIOIT, 981 YOSICIOOT It is not possible to send a message to a task, because some fileds of RTE+ message header are wrong: it is not possible to send a message to PPXL task or out of PPXL system.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = 0x0d INVALID ROUTING FROM TDPC Current value of the variable source_sys Current value of the variable dest_sys Current value of the variable source_mbx Current value of the variable dest_mbx Current value of the variable signal_type Current value of the variable signal_subtype Current value of the variable rtn_error not used not used not used not used not used not used not used

Originator = 990 NOSICIOIT, 991 NOSICIOOT It is not possible to send a message to a task, because some fileds of RTE+ message header are wrong: it is not possible to send a message to PPXU task or out of PPXU system.
aaaa = bbbb = 0x0d INVALID ROUTING FROM TDPC Current value of the variable source_sys

A30808-X3247-K240-3-7619

365

Outputs OML:BSC
cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = Current value of the variable dest_sys Current value of the variable source_mbx Current value of the variable dest_mbx Current value of the variable signal_type Current value of the variable signal_subtype Current value of the variable rtn_error not used not used not used not used not used not used not used

Base Station Controller

##StartSpecProbl##
Specific Problems = 268 BSSGP INVALID MESSAGE

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 7202 PKINGBMGBD, 7206 PKPMDTBDTC, 7207 PKPMDTBDTM, 7216 PKUTBMBLLM Wrong BSSGP message from GbIC is received.
aaaa bbbb cccc dddd eeee ffff gggg = = = = = = = Process State. Process Instance. EDOS Message Code. Process Source line. Procedure Module Originator Procedure Module Line. Cause of release 1 = Wrong primitive ID (h h h h = NS-ID, i i i i = NS-BVCI, j j j j = Not used) 2 = Wrong signal type (h h h h = Not used, i i i i = Not used, j j j j = Not used) 3 = Wrong signal subtype (h h h h = Not used, i i i i = Not used, j j j j = Not used) 4 = Message length error in NS header (h h h h = NS-ID, i i i i = NS-BVCI, j j j j = Not used) 5 = BVCI out of range in NS header (h h h h = NS-ID, i i i i = NS-BVCI, j j j j = Not used) 6 = Wrong NS congestion cause (h h h h = NS-ID, i i i i = NS-BVCI, j j j j = Cause) 7 = Wrong NS status cause (h h h h = NS-ID, i i i i = NS-BVCI, j j j j = Cause) 8 = NS message received in a wrong mailbox (h h h h = NS-ID, i i i i = NS-BVCI, j j j j = Not used) 9 = Wrong PDU type (h h h h = PDU_TYPE, i i i i = Not used, j j j j = Not used) 10 = Mandatory IE not present (h h h h = PDU_TYPE, i i i i = IE-received, j j j j = IE-expected) 11 = Conditional IE not present

366

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
(h h h h = PDU_TYPE, i i i i = IE-received, j j j j = IE-expected) 12 = Wrong mandatory IE (h h h h = PDU_TYPE, i i i i = IE-received, j j j j = IE-expected) 13 = Wrong conditional IE (h h h h = PDU_TYPE, i i i i = IE-received, j j j j = IE-expected) 14 = Wrong optional IE (h h h h h = PDU_TYPE, i i i i = IE-received, j j j j = IE-expected) 15 = Optional IE overflow (h h h h = PDU_TYPE, i i i i = IE-received, j j j j = IE-expected) 16 = Wrong BSSGP length (h h h h = PDU_TYPE, i i i i = Not used, j j j j = Not used) 17 = PDU message in wrong BVC (h h h h = NS-ID, i i i i = NS-BVCI, j j j j = PDU_TYPE) 18 = PDU not supported (h h h h = PDU_TYPE, i i i i = Not used, j j j j = Not used) 19 = Wrong BVCI in header of PCUC/PCUX message (h h h h = NS-ID, i i i i = NS-BVCI, j j j j = PDU_TYPE, k k k k = Second Byte of BSSGP PDU, l l l l = Third byte of BSSGP PDU, m m m m = Fourth byte of BSSGP PDU, n n n n = Fifth byte of BSSGP PDU) 20 = PDU in opposite direction (h h h h = PDU_TYPE, i i i i = Not used, j j j j = Not used)

hhhh iiii jjjj kkkk llll mmmm nnnn oooo

= = = = = = = =

See gggg field. See gggg field See gggg field See gggg field See gggg field See gggg field See gggg field PPCU/PPXU involved (1st byte) and Process Sending Message (2nd byte).

Specific Problems = 346 INVALID MESSAGE FROM PPXL

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 812 TOSICIOIT Some fields of the RTE+ message are wrong, so it is not possible to send a message to a task, after the DUAM reading.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj = = = = = = = = = = 0x32 INVALID_ROUTING_FROM_PPXL Current value of the variable source_sys Current value of the variable dest_sys Current value of the variable source_mbx Current value of the variable dest_mbx Current value of the variable signal_type Current value of the variable signal_subtype Current value of the variable rtn_error=0 Current value of the variable channel_no 0x01 REGULAR_CAPACITY_CONF 0X02 HIGH_CAPACITY_CONF Not used.

kkkk =

A30808-X3247-K240-3-7619

367

Outputs OML:BSC
llll mmmm nnnn oooo = = = = Not used. Not used. Not used. Not used.

Base Station Controller

368

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

68 INVALID MSU RECEIVED


FAILURE EVENT REPORT: NAME = Probable cause = Specific Problems = Event Type = Event Time = Severity = Trend Indication = Notification Identifier = Correlated Notification Identifier = Related MO = Proposed Repair Actions = Additional Text = Originator = Additional Words =
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo <R.T.D.>

<R.T.D.> <R.T.D.> Invalid Msu Received <see legend> <see legend> <R.T.D.> <see legend> <R.T.D.> <R.T.D.> <displayed only during Alarm Alignment> <R.T.D.> <R.T.D.> <see legend> <R.T.D.> <see legend>

Software Version =

Legend:

##StartSpecProbl##
Specific Problems = 106 SCCP INVALID MSU RECEIVED

Event Type = COMMUNICATION FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 7002 TL3N7SCLC010, 7003 TL3N7SCOC040, 7005 TL3N7SCOC020, 7006 TL3N7SCOC010, 7007 TL3N7SCRC010 This error is output when a received MSU contains wrong parameters.
aaaa bbbb cccc dddd = = = = Instance Code of message (see annex D for more details) Source line where the error occurred. Error type. It can assume one of the following values: For all SCCP messages managed in SBS: B = INCORRECT PROT CLASS E = SCCP INVALID ADDRESS INDICATOR F = SCCP INVALID SPC 10 = SCCP INVALID SSN The following values are used only for SCCP management messages (SST/SSA/SSP): 13 = SCMG WRONG LENGTH

A30808-X3247-K240-3-7619

369

Outputs OML:BSC
D = SCMG WRONG FORMAT IDENTIFIER 11 = SCMG WRONG AFFECTED SSN 12 = SCMG WRONG AFFECTED SPC eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used

Base Station Controller

Specific Problems = 168 INVALID MSU RECEIVED

Event Type = COMMUNICATION FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 7015 TL3N7HMDD1, 7018 TL3N7DIST1, 7021 TL3N7HMRT1 This error is output when a received MSU contains wrong parameters
aaaa bbbb cccc dddd = = = = Instance EDOS Signal (see annex D for more details) Source C Line where the error is occurred Error type. It can assume the following values: 1 MTP INVALID DPC 2 MTP INVALID NI 3 MTP INVALID NM H0 4 MTP INVALID H1 5 MTP INVALID SI 6 MTP INVALID H1 ECO 7 MTP INVALID H1 MAN INHIBIT 8 MTP INVALID H1 TAM 9 MTP INVALID OPC A MTP INVALID H0 C MTP INVALID INSTANCE 12 MTP INVALID SLC RECEIVED IN SLT 13 MTP INVALID PRIORITY 14 MTP RECEIVED TAM UP UNAVAILABLE 15 MTP INVALID LENGHT SI NI LOW DPC LOW OPC SLS in ccitt CASE and SLC in ansi case H0 H1 HIGTH DPC (0 in ccitt case) HIGTH OPC (0 in ccitt case) not used

eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn

= = = = = = = = = =

370

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
not used

oooo =

A30808-X3247-K240-3-7619

371

Outputs OML:BSC

Base Station Controller

69 LAPD LINK PROTOCOL FAILURE


FAILURE EVENT REPORT: NAME = Probable cause = Specific Problems = Event Type = Event Time = Severity = Trend Indication = Notification Identifier = Correlated Notification Identifier = Related MO = Proposed Repair Actions = Additional Text = Originator = Additional Words =
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo <R.T.D.>

<R.T.D.> <R.T.D.> Lapd Link Protocol Failure <see legend> <see legend> <R.T.D.> <see legend> <R.T.D.> <R.T.D.> <displayed only during Alarm Alignment> <R.T.D.> <R.T.D.> <see legend> <R.T.D.> <see legend>

Software Version =

Legend:

##StartSpecProbl##
Specific Problems = 174 LPDL LINK UNSTABLE

Event Type = COMMUNICATION FAILURE EVENT Severity = CRITICAL Proposed Repair Actions = 15 CHECK CABLES, CONNECTIONS, LINE QUALITY

Originator = 4802 TDHLPDCEN This error occurs when the device handler of the LAPD links detects repeated link transitions within the threshold period after which it is declared the permanent failure. The LPDL is declared unstable when a threshold number of transitions occur within a threshold period.
aaaa = Current value of the finite state machine (FSM): CDHLP_OOS = 0x00 The link is released and the LPDL operational state is DISABLED. This is the initial state after the link creation, or it reaches this state after an unrecovered link release. CDHLP_INIT = 0x01 The device handler received the establishment indication from layer 2 and wait few msec to filter the initial LAPD transitions: in this period the LPDL state is set to ENABLED Initializing. CDHLP_FILTERING = 0x02 This state gives the possibility to filter eventually a temporary link transition. If the link

372

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
restarts in a few time, the LPDL device handler does not report any operational state transition to Status Manager. CDHLP_MONITOR = 0x03 This is the normal operating condition of the link: established with the operational state set to ENABLED. Layer 2 protocol status: 1 = TEI unassigned 2 = Assign awaiting TEI 3 = Establish awaiting TEI 4 = TEI assigned 5 = Awaiting Establishment 6 = Awaiting Release 7 = Multiple Frame Established 8 = Timer Recovery. Instability counter (developer oriented). Instability Period (developer oriented). System Info Report flag (developer oriented). System Info Report timer (developer oriented). not used not used not used not used not used not used not used not used not used

bbbb =

cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

= = = = = = = = = = = = =

##StartSpecProbl##
Specific Problems = 175 LPDL LINK TRANSITION

Event Type = COMMUNICATION FAILURE EVENT Severity = WARNING Proposed Repair Actions = 5 SEE THE PROPOSED ACTION IN THE MANUAL

Originator = 4802 TDHLPDCEN This warning occurs when the device handler of the LAPD links detects a LAPD link transition within the threshold period after which it is declared the permanent failure. As first action a check on cables and lines quality can be made.
aaaa = bbbb = source code line (developer oriented) Current value of the finite state machine (FSM): CDHLP_OOS = 0x00 The link is released and the LPDL operational state is DISABLED. This is the initial state after the link creation, or it reaches this state after an unrecovered link release. CDHLP_INIT = 0x01 The device handler received the establishment indication from layer 2 and wait few msec to filter the initial LAPD transitions: in this period the LPDL state is set to ENABLED Initializing. CDHLP_FILTERING = 0x02 This state gives the possibility to filter eventually a temporary link transition. If the link restarts in a few time, the LPDL device handler does not report any operational state transition to Status Manager. CDHLP_MONITOR = 0x03

A30808-X3247-K240-3-7619

373

Outputs OML:BSC

Base Station Controller

cccc =

dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

= = = = = = = = = = = =

This is the normal operating condition of the link: established with the operational state set to ENABLED. Event managed by the LAPD DH: CDHLP_TMOUT = 0 tmout occurred CDHLP_ESTABL = 1 link established CDHLP_RELEAS = 2 ink released CDHLP_SMENBL = 3 SM ENABLE command CDHLP_SMDSBL = 4 SM DISABLE command. DH internal operation state of the LAPD. Status Handler operational state of the LAPD. not used not used not used not used not used not used not used not used not used not used

##StartSpecProbl##
Specific Problems = 331 BTSM UNSTABLE ALIGNMENT

Event Type = COMMUNICATION FAILURE EVENT Severity = CRITICAL Proposed Repair Actions = 1 NO ACTION

Originator = 4704 TDHBFDCMC This error occurs when too much fast alignment on BTSM has been triggered: that is more than 5 fast alignment in less than 15 minutes..
aaaa = Incoming event the BTSM DH is handling: BMEVT_NONE = 0x00, BMEVT_TMOUT = 0x01, BMEVT_SWALGOK = 0x02, BMEVT_SWALGEND = 0x03, BMEVT_SWSTRDWLD = 0x04, BMEVT_SWALGFAIL = 0x05, BMEVT_SWREFRESH = 0x06, BMEVT_LINKUP = 0x07, BMEVT_LINKDOWN = 0x08, BMEVT_ABISTMT = 0x09, BMEVT_ABISENDERR = 0x0a, BMEVT_SYSALGNREQ = 0x0b, BMEVT_AUDITFAIL = 0x0c, BMEVT_MSGDSBL = 0x0d, BMEVT_MSGENBL = 0x0e, BMEVT_STOPEVREP = 0x0f, BMEVT_RSTEVREP = 0x10, BMEVT_RESETRES = 0x11, BMEVT_RCVNACK = 0x12, BMEVT_SMENBL = 0x13, BMEVT_SMDSBL = 0x14, BMEVT_SMUNLOCK = 0x15,

374

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
BMEVT_DBDHKLV = 0x16, BMEVT_DBDHERR = 0x17, BMEVT_DBDHREQ = 0x18, BMEVT_DBDHRPL = 0x19, BMEVT_ADMOK = 0x1a, BMEVT_BFSTRTM = 0x1b, BMEVT_ABISDEL = 0x1c BMEVT_SALESOK, = 0x1d BMEVT_SALESFAIL = 0x1e BMEVT_SMLOCK = 0x1f BMEVT_LOCKOK = 0x20 Current state of the BTSM finite state machine BMFSM_LINK_DOWN = 0x00, BMFSM_WAIT_STOP_EVT = 0x01, BMFSM_WAIT_SW_ALIGN = 0x02, BMFSM_WAIT_DB_ALIGN = 0x03, BMFSM_WAIT_RESET_RES = 0x04, BMFSM_WAIT_REST_EVT = 0x05, BMFSM_WAIT_EVT_REP = 0x06, BMFSM_MONITOR = 0x07, BMFSM_WAIT_DBDH = 0x08, BMFSM_WAIT_RELAX_TIME= 0x09 BMFSM_WAIT_SALES_EVT = 0x0a BMFSM_WAIT_LOCK = 0x0b New state of the BTSM finite state machine see above. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

bbbb =

cccc = dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = =

A30808-X3247-K240-3-7619

375

Outputs OML:BSC

Base Station Controller

71 REMOTE ALARM INDICATOR


FAILURE EVENT REPORT: NAME = Probable cause = Specific Problems = Event Type = Event Time = Severity = Trend Indication = Notification Identifier = Correlated Notification Identifier = Related MO = Proposed Repair Actions = Additional Text = Originator = Additional Words =
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo <R.T.D.>

<R.T.D.> <R.T.D.> Remote Alarm Indicator <see legend> <see legend> <R.T.D.> <see legend> <R.T.D.> <R.T.D.> <displayed only during Alarm Alignment> <R.T.D.> <R.T.D.> <see legend> <R.T.D.> <see legend>

Software Version =

Legend:

##StartSpecProbl##
Specific Problems = 112 PCM UNAVAILABLE REMOTE PROBLEMS

Event Type = COMMUNICATION FAILURE EVENT Severity = MAJOR Proposed Repair Actions = 1 NO ACTION

Originator = 4754 TDHTRDCMS This error is generated in corrispondence of a TRAUE FER on PCMA / PCMS objects.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll = = = = = = = = = = = = This nuber identifies the error id on TRAUE. For more details see TRAUEs Error Manual. See TRAUEs Error Manual for additional info related to aaaa error id See TRAUEs Error Manual for additional info related to aaaa error id See TRAUEs Error Manual for additional info related to aaaa error id See TRAUEs Error Manual for additional info related to aaaa error id See TRAUEs Error Manual for additional info related to aaaa error id See TRAUEs Error Manual for additional info related to aaaa error id See TRAUEs Error Manual for additional info related to aaaa error id See TRAUEs Error Manual for additional info related to aaaa error id See TRAUEs Error Manual for additional info related to aaaa error id See TRAUEs Error Manual for additional info related to aaaa error id See TRAUEs Error Manual for additional info related to aaaa error id

376

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
See TRAUEs Error Manual for additional info related to aaaa error id See TRAUEs Error Manual for additional info related to aaaa error id See TRAUEs Error Manual for additional info related to aaaa error id

mmmm = nnnn = oooo =

##StartSpecProbl##
Specific Problems = 204 REMOTE ALARM

Event Type = COMMUNICATION FAILURE EVENT Severity = MAJOR Proposed Repair Actions = 9 CHECK LINE CONFIGURATION/HW ON BOTH SIDE

Originator = 4404 MDHLCSASC The remote alarm indication has been detected on the line. This means that the other network element has decided to disable the line for some alarm on the PCM stream provided by the BSC, notifying the failure to the BSC itself so that it takes the suitable recovery actions.
aaaa = bbbb = cccc = Developer reserved: code line number where error is emitted Licd type (0=DTLP, 1=QTLP, 2=QTLP V2) LOW BYTE contains the logical licd number (the object which manages a group of PCM lines, defined in the database), HIGH BYTE contains the phisycal licd (hardware card effectively in service). It may be different from the logical licd if the LICDS is providing service (9=spare 0, A=spare 1). Line involved (0-3) Link involved (1=link A, 2=link B) signal absent ais alarm present lfa alarm present eer alarm present rai alarm present lca alarm present rnua alarm present LOW BYTE contains : lnua alarm present. HIGH BYTE contains: working mode (DD = double trunk , BB = single trunk ) If LicdType = DTLP then b5 alarm present, it means that the bit no. 5 of the time slot 0 is different from the expected value (1). In some networks of telecommunications it is used to notify the loss of synchronization (timing alarm procedure). For the GSM network however it is generally unused. It is handled only by the DTLP. If LicdType = QTLP V1 or QTLP V2 then alarm causes AA= Pcm Permanent CC = Pcm Micro Interruptions . LOW BYTE contains: txal alarm present, it reveals a wrong parity on the PCM stream transmitted to the LICD by the switching matrix. This signal is transmitted through a bus that is composed, for each LICD, by 4 lines at 8 Mb/s (of which 2 are redunded, and carry the LOW parity signal). This alarm can be induced either by clock problems (due to PLLH), or by some faulted circuit on the switching matrix, or by some fault in the PCM parity checker of the LICD. It is handled only by the QTLP V1. HIGH BYTE contains: type of pcm working mode 24(16h)->PCM24; 32(20h)->PCM32.

dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm

= = = = = = = = = =

nnnn =

oooo =

A30808-X3247-K240-3-7619

377

Outputs OML:BSC

Base Station Controller

##StartSpecProbl##
Specific Problems = 205 REMOTE ALARM ON LINK A

Event Type = COMMUNICATION FAILURE EVENT Severity = MINOR Proposed Repair Actions = 9 CHECK LINE CONFIGURATION/HW ON BOTH SIDE

Originator = 4404 MDHLCSASC This alarm causes a reduction of the redundancy of the line, and can be issued only for PCM lines configured in duplex; it is issued when the remote alarm indication has been detected on link A. This means that the other network element has decided to disable the link for some alarm on the PCM stream provided by the BSC, notifying the failure to the BSC so that it takes the suitable recovery action.
aaaa = bbbb = cccc = Developer reserved: code line number where error is emitted Licd type (0=DTLP, 1=QTLP, 2=QTLP V2) LOW BYTE contains the logical licd number (the object which manages a group of PCM lines, defined in the database), HIGH BYTE contains the phisycal licd (hardware card effectively in service). It may be different from the logical licd if the LICDS is providing service (9=spare 0, A=spare 1). Line involved (0-3) Link involved (1=link A, 2=link B) signal absent ais alarm present lfa alarm present eer alarm present rai alarm present lca alarm present rnua alarm present LOW BYTE contains : lnua alarm present. HIGH BYTE contains: working mode (DD = double trunk , BB = single trunk ) If LicdType = DTLP then b5 alarm present, it means that the bit no. 5 of the time slot 0 is different from the expected value (1). In some networks of telecommunications it is used to notify the loss of synchronization (timing alarm procedure). For the GSM network however it is generally unused. It is handled only by the DTLP. If LicdType = QTLP V1 or QTLP V2 then alarm causes AA= Pcm Permanent CC = Pcm Micro Interruptions . LOW BYTE contains: txal alarm present, it reveals a wrong parity on the PCM stream transmitted to the LICD by the switching matrix. This signal is transmitted through a bus that is composed, for each LICD, by 4 lines at 8 Mb/s (of which 2 are redunded, and carry the LOW parity signal). This alarm can be induced either by clock problems (due to PLLH), or by some faulted circuit on the switching matrix, or by some fault in the PCM parity checker of the LICD. It is handled only by the QTLP V1. HIGH BYTE contains: type of pcm working mode 24(16h)->PCM24; 32(20h)->PCM32.

dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm

= = = = = = = = = =

nnnn =

oooo =

##StartSpecProbl##
Specific Problems = 206 REMOTE ALARM ON LINK B

Event Type = COMMUNICATION FAILURE EVENT Severity = MINOR


378 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Proposed Repair Actions = 9 CHECK LINE CONFIGURATION/HW ON BOTH SIDE

Originator = 4404 MDHLCSASC This alarm causes a reduction of the redundancy of the line, and can be issued only for PCM lines configured in duplex; it is issued when the remote alarm indication has been detected on link B. This means that the other network element has decided to disable the link for some alarm on the PCM stream provided by the BSC, notifying the failure to the BSC so that it takes the suitable recovery action.
aaaa = bbbb = cccc = Developer reserved: code line number where error is emitted Licd type (0=DTLP, 1=QTLP, 2=QTLP V2) LOW BYTE contains the logical licd number (the object which manages a group of PCM lines, defined in the database), HIGH BYTE contains the phisycal licd (hardware card effectively in service). It may be different from the logical licd if the LICDS is providing service (9=spare 0, A=spare 1). Line involved (0-3) Link involved (1=link A, 2=link B) signal absent ais alarm present lfa alarm present eer alarm present rai alarm present lca alarm present rnua alarm present LOW BYTE contains : lnua alarm present. HIGH BYTE contains: working mode (DD = double trunk , BB = single trunk ) If LicdType = DTLP then b5 alarm present, it means that the bit no. 5 of the time slot 0 is different from the expected value (1). In some networks of telecommunications it is used to notify the loss of synchronization (timing alarm procedure). For the GSM network however it is generally unused. It is handled only by the DTLP. If LicdType = QTLP V1 or QTLP V2 then alarm causes AA= Pcm Permanent CC = Pcm Micro Interruptions . LOW BYTE contains: txal alarm present, it reveals a wrong parity on the PCM stream transmitted to the LICD by the switching matrix. This signal is transmitted through a bus that is composed, for each LICD, by 4 lines at 8 Mb/s (of which 2 are redunded, and carry the LOW parity signal). This alarm can be induced either by clock problems (due to PLLH), or by some faulted circuit on the switching matrix, or by some fault in the PCM parity checker of the LICD. It is handled only by the QTLP V1. HIGH BYTE contains: type of pcm working mode 24(16h)->PCM24; 32(20h)->PCM32.

dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm

= = = = = = = = = =

nnnn =

oooo =

##StartSpecProbl##
Specific Problems = 286 NOTIFIED REMOTE ALARM

Event Type = COMMUNICATION FAILURE EVENT Severity = MAJOR Proposed Repair Actions = 15 CHECK CABLES, CONNECTIONS, LINE QUALITY

Originator = 4400 MDHLCDCDE, 4754 TDHTRDCMS


A30808-X3247-K240-3-7619 379

Outputs OML:BSC

Base Station Controller

Error notified by TRAU towards the BSC on PCMS/PCMA objects. See TRAU error manual at error REMOTE_ALARM.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual.

##StartSpecProbl##
Specific Problems = 297 NOTIFIED REMOTE ALARM ON LINK A

Event Type = COMMUNICATION FAILURE EVENT Severity = MINOR Proposed Repair Actions = 15 CHECK CABLES, CONNECTIONS, LINE QUALITY

Originator = 4400 MDHLCDCDE, 4754 TDHTRDCMS Error notified by TRAU towards the BSC on PCMS/PCMA objects. See TRAU error manual at error REMOTE_ALARM_ON_LINK_A.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual.

380

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Specific Problems = 298 NOTIFIED REMOTE ALARM ON LINK B

Event Type = COMMUNICATION FAILURE EVENT Severity = MINOR Proposed Repair Actions = 15 CHECK CABLES, CONNECTIONS, LINE QUALITY

Originator = 4400 MDHLCDCDE, 4754 TDHTRDCMS Error notified by TRAU towards the BSC on PCMS/PCMA objects. See TRAU error manual at error REMOTE_ALARM_ON_LINK_B.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual.

A30808-X3247-K240-3-7619

381

Outputs OML:BSC

Base Station Controller

72 ROUTING FAILURE
FAILURE EVENT REPORT: NAME = Probable cause = Specific Problems = Event Type = Event Time = Severity = Trend Indication = Notification Identifier = Correlated Notification Identifier = Related MO = Proposed Repair Actions = Additional Text = Originator = Additional Words =
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo <R.T.D.>

<R.T.D.> <R.T.D.> Routing Failure <see legend> <see legend> <R.T.D.> <see legend> <R.T.D.> <R.T.D.> <displayed only during Alarm Alignment> <R.T.D.> <R.T.D.> <see legend> <R.T.D.> <see legend>

Software Version =

Legend:

Specific Problems = 107 ROUTING FAILURE

Event Type = COMMUNICATION FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 7002 TL3N7SCLC010, 7006 TL3N7SCOC010 This message is output when the routing of a SCCP message fails.
aaaa bbbb cccc dddd eeee = = = = = Instance EDOS Signal (see annex D for more details) Source C line where the error is occurred Process State Reason of failure. It can assume the following values: 0 = Internal state disaligned 1 = SUBSYSTEM UNAVAILABLE 2 = DPC UNACCESSIBLE Not Used Not Used Not Used Not Used Not Used Not Used

ffff gggg hhhh iiii jjjj kkkk

= = = = = =

382

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = Not Used Not Used Not Used Not Used

llll mmmm nnnn oooo

A30808-X3247-K240-3-7619

383

Outputs OML:BSC

Base Station Controller

73 SS7 PROTOCOL FAILURE


FAILURE EVENT REPORT: NAME = Probable cause = Specific Problems = Event Type = Event Time = Severity = Trend Indication = Notification Identifier = Correlated Notification Identifier = Related MO = Proposed Repair Actions = Additional Text = Originator = Additional Words =
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo <R.T.D.>

<R.T.D.> <R.T.D.> Ss7 Protocol Failure <see legend> <see legend> <R.T.D.> <see legend> <R.T.D.> <R.T.D.> <displayed only during Alarm Alignment> <R.T.D.> <R.T.D.> <see legend> <R.T.D.> <see legend>

Software Version =

Legend:

##StartSpecProbl##
Specific Problems = 169 SS7 LINK ACTIVATION FAILURE

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 7013 TL3N7LMAC2 This error is output when it is not possible to satisfy an activation request of a SS7 link.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll = = = = = = = = = = = = Instance EDOS Signal (see annex D for more details) Source C line where the error is occurred LINK status not used not used not used not used not used not used not used not used

384

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
not used not used not used

mmmm = nnnn = oooo =

##StartSpecProbl##
Specific Problems = 219 UNAVAILABLE SS7 LINKS THRESHOLD MINOR

Event Type = QUALITY OF SERVICE FAILURE EVENT Severity = MINOR Proposed Repair Actions = 1 NO ACTION

Originator = 3111 MSMSHHDHT The percentage of SS7L out of service has exceeded the value defined by operator as minor threshold.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Number of TSLA out of service. Number of SS7-MSC out of service. Number of SS7-LCS out of service. Number of TSLA equipped. Number of SS7-MSC equipped. Number of SS7-LCS equipped. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

##StartSpecProbl##
Specific Problems = 221 UNAVAILABLE SS7 LINKS THRESHOLD MAJOR

Event Type = QUALITY OF SERVICE FAILURE EVENT Severity = MAJOR Proposed Repair Actions = 1 NO ACTION

Originator = 3111 MSMSHHDHT The percentage of SS7L out of service has exceeded the value defined by operator as major threshold.
A30808-X3247-K240-3-7619 385

Outputs OML:BSC
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Number of TSLA out of service. Number of SS7-MSC out of service. Number of SS7-LCS out of service. Number of TSLA equipped. Number of SS7-MSC equipped. Number of SS7-LCS equipped. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

Base Station Controller

##StartSpecProbl##
Specific Problems = 224 UNAVAILABLE SS7 LINKS THRESHOLD CRITICAL

Event Type = QUALITY OF SERVICE FAILURE EVENT Severity = CRITICAL Proposed Repair Actions = 1 NO ACTION

Originator = 3111 MSMSHHDHT The percentage of SS7L out of service has exceeded the value defined by operator as critical threshold.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Number of TSLA out of service. Number of SS7-MSC out of service. Number of SS7-LCS out of service. Number of TSLA equipped. Number of SS7-MSC equipped. Number of SS7-LCS equipped. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

Specific Problems = 252 SS7L FAILURE

386

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Event Type = COMMUNICATION FAILURE EVENT Severity = MINOR Proposed Repair Actions = 1 NO ACTION

Originator = 7022 TL3N7LMAC3, 7023 TL3N7LMAC4 Timer T19 expires


aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Istance Code of message (see annex D for more details) Source line where the error occurred Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used

A30808-X3247-K240-3-7619

387

Outputs OML:BSC

Base Station Controller

74 TRANSMISSION ERROR
FAILURE EVENT REPORT: NAME = Probable cause = Specific Problems = Event Type = Event Time = Severity = Trend Indication = Notification Identifier = Correlated Notification Identifier = Related MO = Proposed Repair Actions = Additional Text = Originator = Additional Words =
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo <R.T.D.>

<R.T.D.> <R.T.D.> Transmission Error <see legend> <see legend> <R.T.D.> <see legend> <R.T.D.> <R.T.D.> <displayed only during Alarm Alignment> <R.T.D.> <R.T.D.> <see legend> <R.T.D.> <see legend>

Software Version =

Legend:

##StartSpecProbl##
Specific Problems = 059 REMOTE LOWER BER THRESHOLD EXCEEDED

Event Type = COMMUNICATION FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 4754 TDHTRDCMS This error is generated in corrispondence of a TRAUE FER "PCM LOWER BER EXCEEDED" on PCMA / PCMS objects.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk = = = = = = = = = = = This nuber identifies the error id on TRAUE. For more details see TRAUEs Error Manual. See TRAUEs Error Manual for additional info related to aaaa error id See TRAUEs Error Manual for additional info related to aaaa error id See TRAUEs Error Manual for additional info related to aaaa error id See TRAUEs Error Manual for additional info related to aaaa error id See TRAUEs Error Manual for additional info related to aaaa error id See TRAUEs Error Manual for additional info related to aaaa error id See TRAUEs Error Manual for additional info related to aaaa error id See TRAUEs Error Manual for additional info related to aaaa error id See TRAUEs Error Manual for additional info related to aaaa error id See TRAUEs Error Manual for additional info related to aaaa error id

388

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = See TRAUEs Error Manual for additional info related to aaaa error id See TRAUEs Error Manual for additional info related to aaaa error id See TRAUEs Error Manual for additional info related to aaaa error id See TRAUEs Error Manual for additional info related to aaaa error id

llll mmmm nnnn oooo

##StartSpecProbl##
Specific Problems = 201 HIGHER BER THRESHOLD EXCEEDED

Event Type = COMMUNICATION FAILURE EVENT Severity = MAJOR Proposed Repair Actions = 10 CHECK THE LICD PCM CABLE, TUNE THE BER

Originator = 4404 MDHLCSASC The Bit Error Ratio has exceeded the higher threshold (whose value is set by the operator together with all the other parameters of the PCM line). This can be due either to disturbs or to a big attenuation on the PCM signal.
aaaa = bbbb = cccc = Developer reserved: code line number where error is emitted Licd type (0=DTLP, 1=QTLP, 2=QTLP V2) LOW BYTE contains the logical licd number (the object which manages a group of PCM lines, defined in the database), HIGH BYTE contains the phisycal licd (hardware card effectively in service). It may be different from the logical licd if the LICDS is providing service (9=spare 0, A=spare 1). Line involved (0-3) Link involved (1=link A, 2=link B) signal absent ais alarm present lfa alarm present eer alarm present rai alarm present lca alarm present rnua alarm present LOW BYTE contains : lnua alarm present. HIGH BYTE contains: working mode (DD = double trunk , BB = single trunk ) If LicdType = DTLP then b5 alarm present, it means that the bit no. 5 of the time slot 0 is different from the expected value (1). In some networks of telecommunications it is used to notify the loss of synchronization (timing alarm procedure). For the GSM network however it is generally unused. It is handled only by the DTLP. If LicdType = QTLP V1 or QTLP V2 then alarm causes AA= Pcm Permanent CC = Pcm Micro Interruptions . LOW BYTE contains: txal alarm present, it reveals a wrong parity on the PCM stream transmitted to the LICD by the switching matrix. This signal is transmitted through a bus that is composed, for each LICD, by 4 lines at 8 Mb/s (of which 2 are redunded, and carry the LOW parity signal). This alarm can be induced either by clock problems (due to PLLH), or by some faulted circuit on the switching matrix, or by some fault in the PCM parity checker of the LICD. It is handled only by the QTLP V1. HIGH BYTE contains: type of pcm working mode 24(16h)->PCM24; 32(20h)->PCM32.

dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm

= = = = = = = = = =

nnnn =

oooo =

A30808-X3247-K240-3-7619

389

Outputs OML:BSC

Base Station Controller

##StartSpecProbl##
Specific Problems = 202 HIGHER BER THRESHOLD EXCEEDED ON LINK A

Event Type = COMMUNICATION FAILURE EVENT Severity = MINOR Proposed Repair Actions = 10 CHECK THE LICD PCM CABLE, TUNE THE BER

Originator = 4404 MDHLCSASC The Bit Error Ratio has exceeded the higher threshold (whose value is set by the operator together with all the other parameters of the LICD) on link A. This can be due either to disturbs or to a big attenuation on the PCM signal. This alarm causes a reduction of the redundancy of the line, and can be issued only for PCM lines configured in duplex.
aaaa = bbbb = cccc = Developer reserved: code line number where error is emitted Licd type (0=DTLP, 1=QTLP, 2=QTLP V2) LOW BYTE contains the logical licd number (the object which manages a group of PCM lines, defined in the database), HIGH BYTE contains the phisycal licd (hardware card effectively in service). It may be different from the logical licd if the LICDS is providing service (9=spare 0, A=spare 1). Line involved (0-3) Link involved (1=link A, 2=link B) signal absent ais alarm present lfa alarm present eer alarm present rai alarm present lca alarm present rnua alarm present LOW BYTE contains : lnua alarm present. HIGH BYTE contains: working mode (DD = double trunk , BB = single trunk ) If LicdType = DTLP then b5 alarm present, it means that the bit no. 5 of the time slot 0 is different from the expected value (1). In some networks of telecommunications it is used to notify the loss of synchronization (timing alarm procedure). For the GSM network however it is generally unused. It is handled only by the DTLP. If LicdType = QTLP V1 or QTLP V2 then alarm causes AA= Pcm Permanent CC = Pcm Micro Interruptions . LOW BYTE contains: txal alarm present, it reveals a wrong parity on the PCM stream transmitted to the LICD by the switching matrix. This signal is transmitted through a bus that is composed, for each LICD, by 4 lines at 8 Mb/s (of which 2 are redunded, and carry the LOW parity signal). This alarm can be induced either by clock problems (due to PLLH), or by some faulted circuit on the switching matrix, or by some fault in the PCM parity checker of the LICD. It is handled only by the QTLP V1. HIGH BYTE contains: type of pcm working mode 24(16h)->PCM24; 32(20h)->PCM32.

dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm

= = = = = = = = = =

nnnn =

oooo =

##StartSpecProbl##
Specific Problems = 203 HIGHER BER THRESHOLD EXCEEDED ON LINK B

Event Type = COMMUNICATION FAILURE EVENT Severity = MINOR Proposed Repair Actions = 10 CHECK THE LICD PCM CABLE, TUNE THE BER
390 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Originator = 4404 MDHLCSASC The Bit Error Ratio has exceeded the higher threshold (whose value is set by the operator together with all the other parameters of the LICD) on link B. This can be due either to disturbs or to a big attenuation on the PCM signal. This alarm causes a reduction of the redundancy of the line, and can be issued only for PCM lines configured in duplex.
aaaa = bbbb = cccc = Developer reserved: code line number where error is emitted Licd type (0=DTLP, 1=QTLP, 2=QTLP V2) LOW BYTE contains the logical licd number (the object which manages a group of PCM lines, defined in the database), HIGH BYTE contains the phisycal licd (hardware card effectively in service). It may be different from the logical licd if the LICDS is providing service (9=spare 0, A=spare 1). Line involved (0-3) Link involved (1=link A, 2=link B) signal absent ais alarm present lfa alarm present eer alarm present rai alarm present lca alarm present rnua alarm present LOW BYTE contains : lnua alarm present. HIGH BYTE contains: working mode (DD = double trunk , BB = single trunk ) If LicdType = DTLP then b5 alarm present, it means that the bit no. 5 of the time slot 0 is different from the expected value (1). In some networks of telecommunications it is used to notify the loss of synchronization (timing alarm procedure). For the GSM network however it is generally unused. It is handled only by the DTLP. If LicdType = QTLP V1 or QTLP V2 then alarm causes AA= Pcm Permanent CC = Pcm Micro Interruptions . LOW BYTE contains: txal alarm present, it reveals a wrong parity on the PCM stream transmitted to the LICD by the switching matrix. This signal is transmitted through a bus that is composed, for each LICD, by 4 lines at 8 Mb/s (of which 2 are redunded, and carry the LOW parity signal). This alarm can be induced either by clock problems (due to PLLH), or by some faulted circuit on the switching matrix, or by some fault in the PCM parity checker of the LICD. It is handled only by the QTLP V1. HIGH BYTE contains: type of pcm working mode 24(16h)->PCM24; 32(20h)->PCM32.

dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm

= = = = = = = = = =

nnnn =

oooo =

##StartSpecProbl##
Specific Problems = 210 LOWER BER THRESHOLD EXCEEDED ON LINK A

Event Type = COMMUNICATION FAILURE EVENT Severity = MINOR Proposed Repair Actions = 10 CHECK THE LICD PCM CABLE, TUNE THE BER

Originator = 4404 MDHLCSASC This error is valid for licd type QTLP V2 only (not valid for DTLP , QTLP V1) .
A30808-X3247-K240-3-7619 391

Outputs OML:BSC

Base Station Controller

The Bit Error Ratio has exceeded the lower threshold (whose value is set by the operator together with all the other parameters of the PCM line) on the link A of the PCM line. This can be due either to disturbs or to a big attenuation on the PCM signal.
aaaa = bbbb = cccc = Developer reserved: code line number where error is emitted Licd type (0=DTLP, 1=QTLP V1, 2=QTLP V2) LOW BYTE contains the logical licd number (the object which manages a group of PCM lines, defined in the database), HIGH BYTE contains the phisycal licd (hardware card effectively in service). It may be different from the logical licd if the LICDS is providing service (9=spare 0, A=spare 1). Line involved (0-3) Link involved (1=link A, 2=link B, 3=both links) not used not used PCM working mode (24 => PCM24; 32 => PCM32) Working mode (DD = double trunk , BB = single trunk ) not used not used not used not used not used not used

dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

= = = = = = = = = = = =

##StartSpecProbl##
Specific Problems = 211 LOWER BER THRESHOLD EXCEEDED ON LINK B

Event Type = COMMUNICATION FAILURE EVENT Severity = MINOR Proposed Repair Actions = 10 CHECK THE LICD PCM CABLE, TUNE THE BER

Originator = 4404 MDHLCSASC This error is valid for licd type QTLP V2 only (not valid for DTLP , QTLP V1) . The Bit Error Ratio has exceeded the lower threshold (whose value is set by the operator together with all the other parameters of the PCM line) on the link B of the PCM line. This can be due either to disturbs or to a big attenuation on the PCM signal.
aaaa = bbbb = cccc = Developer reserved: code line number where error is emitted Licd type (0=DTLP, 1=QTLP V1, 2=QTLP V2) LOW BYTE contains the logical licd number (the object which manages a group of PCM lines, defined in the database), HIGH BYTE contains the phisycal licd (hardware card effectively in service). It may be different from the logical licd if the LICDS is providing service (9=spare 0, A=spare 1). Line involved (0-3) Link involved (1=link A, 2=link B, 3=both links) not used not used PCM working mode (24 => PCM24; 32 => PCM32) Working mode (DD = double trunk , BB = single trunk ) not used not used

dddd eeee ffff gggg hhhh iiii jjjj kkkk

= = = = = = = =

392

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = not used not used not used not used

llll mmmm nnnn oooo

##StartSpecProbl##
Specific Problems = 287 NOTIFIED HIGHER BER THRESHOLD EXCEEDED

Event Type = COMMUNICATION FAILURE EVENT Severity = MAJOR Proposed Repair Actions = 15 CHECK CABLES, CONNECTIONS, LINE QUALITY

Originator = 4400 MDHLCDCDE, 4754 TDHTRDCMS Error notified by TRAU towards the BSC on PCMS/PCMA objects. See TRAU error manual at error HIGHER_BER_THRESHOLD_EXCEEDED.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual.

##StartSpecProbl##
Specific Problems = 288 NOTIFIED LOWER BER THRESHOLD EXCEEDED

Event Type = COMMUNICATION FAILURE EVENT Severity = MINOR Proposed Repair Actions = 15 CHECK CABLES, CONNECTIONS, LINE QUALITY

Originator = 4400 MDHLCDCDE,4754 TDHTRDCMS Error notified by TRAU towards the BSC on PCMS/PCMA objects . See TRAU error
A30808-X3247-K240-3-7619 393

Outputs OML:BSC

Base Station Controller

manual at error LOWER_BER_THRESHOLD_EXCEEDED.


aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual.

##StartSpecProbl##
Specific Problems = 299 NOTIFIED HIGHER BER THRESHOLD EXCEEDED ON LINK A

Event Type = COMMUNICATION FAILURE EVENT Severity = MINOR Proposed Repair Actions = 15 CHECK CABLES, CONNECTIONS, LINE QUALITY

Originator = 4400 MDHLCDCDE, 4754 TDHTRDCMS Error notified by TRAU towards the BSC on PCMS/PCMA objects. See TRAU error manual at error HIGHER_BER_THRESHOLD_EXCEEDED_ON_LINK_A.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual.

394

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

##StartSpecProbl##
Specific Problems = 300 NOTIFIED HIGHER BER THRESHOLD EXCEEDED ON LINK B

Event Type = COMMUNICATION FAILURE EVENT Severity = MINOR Proposed Repair Actions = 15 CHECK CABLES, CONNECTIONS, LINE QUALITY

Originator = 4400 MDHLCDCDE, 4754 TDHTRDCMS Error notified by TRAU towards the BSC on PCMS/PCMA objects. See TRAU error manual at error HIGHER_BER_THRESHOLD_EXCEEDED_ON_LINK_B.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual.

##StartSpecProbl##
Specific Problems = 301 NOTIFIED LOWER BER THRESHOLD EXCEEDED ON LINK A

Event Type = COMMUNICATION FAILURE EVENT Severity = MINOR Proposed Repair Actions = 15 CHECK CABLES, CONNECTIONS, LINE QUALITY

Originator = 4400 MDHLCDCDE, 4754 TDHTRDCMS Error notified by TRAU towards the BSC on PCMS/PCMA objects. See TRAU error manual at error LOWER_BER_THRESHOLD_EXCEEDED_ON_LINK_A.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj = = = = = = = = = = See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual.

A30808-X3247-K240-3-7619

395

Outputs OML:BSC
kkkk llll mmmm nnnn oooo = = = = = See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual.

Base Station Controller

Specific Problems = 302 NOTIFIED LOWER BER THRESHOLD EXCEEDED ON LINK B

Event Type = COMMUNICATION FAILURE EVENT Severity = MINOR Proposed Repair Actions = 15 CHECK CABLES, CONNECTIONS, LINE QUALITY

Originator = 4400 MDHLCDCDE, 4754 TDHTRDCMS Error notified by TRAU towards the BSC on PCMS/PCMA objects. See TRAU error manual at error LOWER_BER_THRESHOLD_EXCEEDED_ON_LINK_B.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual.

396

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

ISO, PROBABLE CAUSES

07 CONFIGURATION OR CUSTOMIZATION ERROR


FAILURE EVENT REPORT: NAME = Probable cause = Specific Problems = Event Type = Event Time = Severity = Trend Indication = Notification Identifier = Correlated Notification Identifier = Related MO = Proposed Repair Actions = Additional Text = Originator = Additional Words =
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo <R.T.D.>

<R.T.D.> <R.T.D.> Configuration Or Customization Error <see legend> <see legend> <R.T.D.> <see legend> <R.T.D.> <R.T.D.> <displayed only during Alarm Alignment> <R.T.D.> <R.T.D.> <see legend> <R.T.D.> <see legend>

Software Version =

Legend:

##StartSpecProbl##
Specific Problems = 016 BTSM SOFTWARE VERSION NOT DEFINED

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 5 SEE THE PROPOSED ACTION IN THE MANUAL

Originator = 126 MOSSDNSBL the system has found the attribute 'Expected Sw Version' for a Btsm not defined during a BTSE Sw Alignment .
aaaa bbbb cccc dddd eeee = = = = = Btsm number Not used Not used Not used Not used

A30808-X3247-K240-3-7619

397

Outputs OML:BSC
ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used

Base Station Controller

##StartSpecProbl##
Specific Problems = 017 TRAU SOFTWARE VERSION NOT DEFINED

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 5 SEE THE PROPOSED ACTION IN THE MANUAL

Originator = 127 MOSSDNSTL the system has found the attribute 'Expected Sw Version' for a Trau not defined during a Trau Sw Alignment .
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Trau number. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

##StartSpecProbl##
Specific Problems = 055 AP BTS IDENTIFIER FAULT

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

398

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Originator = 7100 TL3RDALL Reading/ Updating database error : Bts Identifier mismatch.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Process Identifier (see annex D for more details) Process Instance Process State Not Used Process Source Line Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used

##StartSpecProbl##
Specific Problems = 057 AP CELL NOT CONFIGURED

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 7100 TL3RDALL Reading/ Updating database error : cell identifier not equipped.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Process Identifier (see annex D for more details) Process Instance Process State Not used Process Source Line Cell Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used

A30808-X3247-K240-3-7619

399

Outputs OML:BSC

Base Station Controller

##StartSpecProbl##
Specific Problems = 058 AP CHANNEL NOT CONFIGURED

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 7100 TL3RDALL Reading/ Updating database error : channel combination not equipped.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Process Identifier (see annex D for more details) Process Instance Process State Not Used Process Source Line Cell Trx in the cell Channel Not Used Not Used Not Used Not Used Not Used Not Used Not Used

##StartSpecProbl##
Specific Problems = 067 AP TRX NOT CONFIGURED

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 7100 TL3RDALL Reading/Writing database error : trx index offset mismatch.
aaaa bbbb cccc dddd eeee ffff gggg hhhh = = = = = = = = Process Identifier (see annex D for more details) Process Instance Process State Not Used Process Source Line Not Used Not Used Not Used

400

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = = = = Not Used Not Used Not Used Not Used Not Used Not Used Not Used

iiii jjjj kkkk llll mmmm nnnn oooo

##StartSpecProbl##
Specific Problems = 072 AP AIR TIMER FAULT

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 7100 TL3RDALL The requested A-interface timer was not equipped.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Process Identifier (see annex D for more details) Process Instance Process State Not Used Process Source Line Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used

##StartSpecProbl##
Specific Problems = 073 AP CELL GLOBAL IDENTIFICATION NOT PRESENT

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 7100 TL3RDALL


A30808-X3247-K240-3-7619 401

Outputs OML:BSC

Base Station Controller

The cell with the specified Cell Global Identification parameters is not equipped.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Process Identifier (see annex D for more details) Process Instance Process State Not Used Process Source Line Mcc Mnc Lac Ci Not Used Not Used Not Used Not Used Not Used Not Used

##StartSpecProbl##
Specific Problems = 075 AP CELL IDENTIFICATION NOT PRESENT

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 7100 TL3RDALL The cell identified by the Cell Identification parameter is not equipped.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Process Identifier (see annex D for more details) Process Instance Process State Not Used Process Source Line Ci Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used

402

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

##StartSpecProbl##
Specific Problems = 081 AP LOCATION AREA CODE CELL IDENTIFICATION NOT PRESENT

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 7100 TL3RDALL The cell identified by the Location Area and Cell Identification parameters is not equipped.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Process Identifier (see annex D for more details) Process Instance Process State Not Used Process Source Line Lac Ci Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used

##StartSpecProbl##
Specific Problems = 082 AP LOCATION AREA CODE NOT PRESENT

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 7100 TL3RDALL The cell identified by the Location Area code is not equipped.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll = = = = = = = = = = = = Process Identifier (see annex D for more details) Process Instance Process State Not used Process Source Line Lac Not Used Not Used Not Used Not Used Not Used Not Used

A30808-X3247-K240-3-7619

403

Outputs OML:BSC
mmmm = nnnn = oooo = Not Used Not Used Not Used

Base Station Controller

##StartSpecProbl##
Specific Problems = 083 AP LOCATION AREA IDENTIFICATION NOT PRESENT

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 7100 TL3RDALL Reading database error : Location Area Identification not equipped.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Process Identifier (see annex D for more details) Process Instance Process State Not used Process Source Line Mcc Mnc Lac Not Used Not Used Not Used Not Used Not Used Not Used Not Used

##StartSpecProbl##
Specific Problems = 089 AP NO ADJACENT CELL

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 7100 TL3RDALL The target cell was not found in the adjacent list of the serving cell.
aaaa = bbbb = Process Identifier (see annex D for more details) Process Instance

404

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = = = = = = = = = = Process State Not used Process Source Line Cell Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used

cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

##StartSpecProbl##
Specific Problems = 090 AP NO CELL PRESENT

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 7100 TL3RDALL Reading database error : no cell is equipped in the system.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Process Identifier (see annex D for more details) Process Instance Process State Not Used Process Source Line Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used

##StartSpecProbl##
Specific Problems = 093 AP NO TERRESTRIAL CHANNEL

Event Type = PROCESSING FAILURE EVENT Severity = WARNING


A30808-X3247-K240-3-7619 405

Outputs OML:BSC

Base Station Controller

Proposed Repair Actions = 1 NO ACTION

Originator = 7100 TL3RDALL Reading/updating database error: the terrestrial channel (PCM multiplex and timeslot) has not a Circuit Identity Code associated as described in GSM 08.08.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Process Identifier (see annex D for more details) Process Instance Process State Not Used Process Source Line Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used

##StartSpecProbl##
Specific Problems = 103 AP HW CIRCUIT IDENTITY CODE NOT CONFIGURED

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 7100 TL3RDALL The requested Circuit Identity Code was not equipped.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Process Identifier (see annex D for more details) Process Instance Process State Not used Process source line Hcic Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used

406

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

##StartSpecProbl##
Specific Problems = 110 UNEXPECTED LPDL ESTABLISHED

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 5 SEE THE PROPOSED ACTION IN THE MANUAL

Originator = 4803 TDHLPSASC This error is issued when a request to establish an unrecognized lpdl arrives to the LAPD device handler.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = source code line (developer oriented) logical PPLD dchannel tei: terminal endpoint identifier sapi: service access point identifier result of dba function me_id: PCMB / PCMS me_id: PCMB / PCMS me_id: PCMB / PCMS time slot number sub time slot number not used not used not used not used

##StartSpecProbl##
Specific Problems = 135 AP BTS WITHOUT ALL BBSIG44 CARDS

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 5 SEE THE PROPOSED ACTION IN THE MANUAL

Originator = 7100 TL3RDALL During call processing involving 14.4 kb/s data calls, it has been verified that some messages (i.e. Channel Activation/Channel Activation Nack and/or Mode Modify Request/Mode Modify Nack) have been exchanged with TRX not supporting the service (no BBSIG44 cards).
aaaa = bbbb = Process identifier (see annex D for more details) Process Instance

A30808-X3247-K240-3-7619

407

Outputs OML:BSC
cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = Process State not used. Process Source Line BTS number TRX number not used. not used. not used. not used. not used. not used. not used. not used.

Base Station Controller

##StartSpecProbl##
Specific Problems = 157 INVALID TYPE OF SN

Event Type = PROCESSING FAILURE EVENT Severity = MAJOR Proposed Repair Actions = 12 CHECK THE CONFIGURATION/HW COMPATIBILITY

Originator = 4202 MDHNWDCSC, 4204 MDHNWININ, 4206 MDHNWDCDE The type of switching matrix (SN64, SN16 or SNAP) that is physically in frame is not consistent with the attribute of the BSC. This error causes the network object to become disabled/offline, because it cannot work for the required feature
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = code source line where error occurred Originator which identifies the high level source file which has detected the failure Code line of the high level source file. Type of SN required Type of SN actually present in the rack not used not used not used not used not used not used not used not used not used not used

408

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

##StartSpecProbl##
Specific Problems = 160 INVALID TYPE OF PLLH

Event Type = PROCESSING FAILURE EVENT Severity = MINOR Proposed Repair Actions = 12 CHECK THE CONFIGURATION/HW COMPATIBILITY

Originator = 4202 MDHNWDCSC, 4204 MDHNWININ The type of PLLH that is physically in frame is not consistent with the attribute PCMTYPE of the BSC: this can happen if this attribute is PCM24 and the PLLH is of an old edition ("V0"), which does not support the synchronization with the PCMS lines at 1544 KHz. This error causes the network object to become disabled/offline, because it cannot work for the required feature. The error with originator MDHNWDCDE is issued as a consequence of a set BSC command with change of the attribute PCMTYPE from PCM32 to PCM24.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = code source line where error occurred Originator which identifies the high level source file which has detected the failure Code line of the high level source file. Not meaningful Not meaningful not used not used not used not used not used not used not used not used not used not used

##StartSpecProbl##
Specific Problems = 162 INVALID TYPE OF LICD

Event Type = PROCESSING FAILURE EVENT Severity = MINOR Proposed Repair Actions = 12 CHECK THE CONFIGURATION/HW COMPATIBILITY

Originator = 4400 MDHLCDCDE


A30808-X3247-K240-3-7619 409

Outputs OML:BSC

Base Station Controller

The type of LICD that is physically in frame is not consistent with the attributes NTWCARD or ASUBENCAP of the BSC basic package: this can happen if ASUBENCAP is TRUE, and the QTLP is of an old edition ("V1"), which does not support correctly the lines in transparent mode, or if the NTWCARD is NTWSN16, and the LICD is a DTLP. The same error occurs if the NTWCARD attribute is NTWSN64 and the card in the slot is a QTLP. This error causes the LICD object to become disabled/offline, because it cannot work for the required feature.
aaaa bbbb cccc dddd = = = = Developer reserved: code line number where error is emitted Developer reserved: error originator where error was detected Developer reserved: code line number where error was detected Expected LICD type (low byte) and LICD present in the slot (high byte), where 0=DTLP; 1=QTLP V1, 2=QTLP V2 Developer reserved: cmdreg (low byte); type of licd present in the slot (high byte; redounded of dddd): 0->DTLP; 1->QTLP V1; 2->QTLP V2. Mask of card line relays status (1=closed,0=open) Mask of card mate relays status (1=closed,0=open) Mask of physical pcm lines cutover status (1=line under cutover,0=line not cutovered) Ubex copy active (low byte); type of pcm working mode (high byte): 24(16h)->PCM24; 32(20h)->PCM32. Developer reserved: "hwchk" it should be 0x82, otherwise, a FW error has occurred Developer reserved: "cmdecho" value of the last command sent by MPCC to the FW of LICD Developer reserved: fwresp[0] Developer reserved: fwresp[1] Developer reserved: fwresp[2] Developer reserved: fwresp[3]

eeee = ffff gggg hhhh iiii = = = =

jjjj = kkkk = llll mmmm nnnn oooo = = = =

##StartSpecProbl##
Specific Problems = 270 CONFIGURATION MISMATCH

Event Type = PROCESSING FAILURE EVENT Severity = MINOR Proposed Repair Actions = 8 CHECK LINE CONFIGURATION ON BOTH SIDE

Originator = 4953 TDHGPIHGB This error occurs when the NS layer of the Gb interface fails on network side or a NSBLOCK is received by the network.
aaaa = bbbb = the line number of the source module the cause of NS link down: 0x04 - PVC_LINK_ACTIVE 0x05 - PVC_LINK_FAIL 0x06 - NS_LINK_ALIVE 0x07 - NS_LINK_UNBLOCKED 0x08 - NS_LINK_BLOCKED 0x09 - OM_UNBLOCK_OK 0x0A - OM_BLOCK_OK 0x0B - NS_LINK_DEAD 0x0C - NS_TEST_FAIL 0x0D - NS_RESET_REQUEST 0x0E - OM_BLOCK_FAIL GbIC prc state:

cccc =

410

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
0xFF - GB_NOT_CREATED 0x00 - GB_INITIALIZING 0x01 - GB_ACTIVE 0x02 - GB_FAILURE 0x03 - GB_BLOCKED 0x04 - GB_UNBLOCKED 0x05 - GB_PVC_FAIL 0x06 - GB_SETTING 0x07 - GB_DELETING 0xFE - GB_ERROR GbIC ope state: 0xFF - GB_NULL 0x04 - NSVC_LOCAL_NOT_AVAILABLE 0x05 - NSVC_REMOTE_NOT_AVAILABLE 0x06 - NSVC_ALIVE GbIC prot state: 0xFF - NSVC_NOT_CREATED 0x00 - NSVC_CREATING 0x01 - NSVC_ATTACHING_LINK 0x02 - NSVC_PVC_LINK_WAITING 0x03 - NSVC_PVC_LINK_FAILURE 0x04 - NSVC_DEAD_INITIALIZING 0x05 - NSVC_DEAD_BLOCKING 0x06 - NSVC_DEAD_BLOCKED 0x07 - NSVC_ALIVE_BLOCKED 0x08 - NSVC_ALIVE_UNBLOCKING 0x09 - NSVC_ALIVE_BLOCKING 0x0A - NSVC_ALIVE_UNBLOCKED 0x0B - NSVC_CHANGING_ATTRIBUTES 0x0C - NSVC_DETACHING_LINK 0x0D - NSVC_DELETING 0xFE - NSVC_ERROR Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used

dddd =

eeee =

ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

= = = = = = = = = =

##StartSpecProbl##
Specific Problems = 276 AP BVC NOT CONFIGURED

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 7100 TL3RDALL Reading/ Updating database error : BVC not equipped.
aaaa = Process Identifier (see annex D for more details)

A30808-X3247-K240-3-7619

411

Outputs OML:BSC
bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = Process Instance Process State Not used Process Source Line BVC index Not used Not used Not used Not used Not used Not used Not used Not used Not used

Base Station Controller

##StartSpecProbl##
Specific Problems = 278 AP PCU NOT CONFIGURED

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 7100 TL3RDALL Reading/ Updating database error : PCU not equipped.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Process Identifier (see annex D for more details) Process Instance Process State Not used Process Source Line Pcu Index Not used Not used Not used Not used Not used Not used Not used Not used Not used

##StartSpecProbl##
Specific Problems = 280 AP PDT NOT CONFIGURED

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION
412 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Originator = 7200 PKINRMMRMD A Reference to a not existent PDT is found


aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Process State. Process Instance EDOS message code Process Source Line Procedure Module Originator Procedure Module Line Not used Not used Not used Not used Not used Not used Not used Not used PPCU/PPXU involved (1st byte) and Process Message Originator (2nd byte)

Originator = 7100 TL3RDALL Reading/ Updating database error : PDT not equipped.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Process Identifier (see annex D for more details) Process Instance Process State Not used Process Source Line PCU index PDT index Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used

##StartSpecProbl##
Specific Problems = 306 AP ROUTING AREA CODE NOT PRESENT

Event Type = PROCESSING FAILURE EVENT


A30808-X3247-K240-3-7619 413

Outputs OML:BSC

Base Station Controller

Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 7100 TL3RDALL Reading database error : Routing Area Code not present.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Process Identifier (see annex D for more details) Process Instance Process State Not used Process Source Line Mcc Mnc Lac Rac Not Used Not Used Not Used Not Used Not Used Not Used

414

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

08 CONGESTION
FAILURE EVENT REPORT: NAME = Probable cause = Specific Problems = Event Type = Event Time = Severity = Trend Indication = Notification Identifier = Correlated Notification Identifier = Related MO = Proposed Repair Actions = Additional Text = Originator = Additional Words =
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo <R.T.D.>

<R.T.D.> <R.T.D.> Congestion <see legend> <see legend> <R.T.D.> <see legend> <R.T.D.> <R.T.D.> <displayed only during Alarm Alignment> <R.T.D.> <R.T.D.> <see legend> <R.T.D.> <see legend>

Software Version =

Legend:

##StartSpecProbl##
Specific Problems = 043 START THROTTLING ERROR

Event Type = QUALITY OF SERVICE FAILURE EVENT Severity = MINOR Proposed Repair Actions = 1 NO ACTION

Originator = 3002 MSMARECTH, 3502 TSMARECTH, 3702 USMARECTH Error Collector on MPCC / TDPC communicates that message buffers with INDUCED error that will arrive on its mailbox, from this time, are saved in a special throttling queue, because error collector has too many of them to process.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii = = = = = = = = = not used not used not used not used not used not used not used not used not used

A30808-X3247-K240-3-7619

415

Outputs OML:BSC
jjjj kkkk llll mmmm nnnn oooo = = = = = = not used not used not used not used not used not used

Base Station Controller

##StartSpecProbl##
Specific Problems = 273 OVERFLOW OF COMMANDS TABLES

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 10102 MFTRS It is used to indicate that context table is congestioned, where context table refers in this subsystem to thw table containing information about ftrs (FTAM Responder) task active on MPCC. So no more ftrs task are allowed to use this table and to be started.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = not used not used not used not used not used not used not used not used not used not used not used not used not used not used not used

Originator = 10104 MBAMW It is used to indicate that the Job Number Table or the Invoke Identifier Table are full. Those tables are used by MBAMW functions to handle the association message-command.
aaaa bbbb cccc dddd eeee ffff = = = = = = not used not used not used not used not used not used

416

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = = = = = = not used not used not used not used not used not used not used not used not used

gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

A30808-X3247-K240-3-7619

417

Outputs OML:BSC

Base Station Controller

09 CORRUPT DATA
FAILURE EVENT REPORT: NAME = Probable cause = Specific Problems = Event Type = Event Time = Severity = Trend Indication = Notification Identifier = Correlated Notification Identifier = Related MO = Proposed Repair Actions = Additional Text = Originator = Additional Words =
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo <R.T.D.>

<R.T.D.> <R.T.D.> Corrupt Data <see legend> <see legend> <R.T.D.> <see legend> <R.T.D.> <R.T.D.> <displayed only during Alarm Alignment> <R.T.D.> <R.T.D.> <see legend> <R.T.D.> <see legend>

Software Version =

Legend:

##StartSpecProbl##
Specific Problems = 147 INVALID MESSAGE TO RTE

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 308 MOSICIOIT It is not possible to have an RTE+ message from the specified pool or the pool chosen is an invalid pool.
aaaa = bbbb cccc dddd eeee ffff gggg hhhh iiii = = = = = = = = 0x24 INVALID_MESSAGE_POINTER. 0x25 INVALID_MESSAGE_FIELD. Current value of the variable source_sys. Current value of the variable dest_sys. Current value of the variable source_mbx. Current value of the variable dest_mbx. Current value of the variable msg_type. Current value of the variable msg_subtype. Current value of the variable len. Not used.

418

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = = = Not used. Not used. Not used. Not used. Not used. Not used.

jjjj kkkk llll mmmm nnnn oooo

##StartSpecProbl##
Specific Problems = 005 CHECK ON FILE CONTENTS FAILED

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 5 SEE THE PROPOSED ACTION IN THE MANUAL

Originator = 133 MOSSDFSDS The BSC executable file that was being transferred has a wrong format.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any) Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to locate the instruction (line of third calling instruction, if any). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any). Not used. Not used. Not used. Not used. Not used. Not used. Not used.

Originator = 501 MSDLSLTPL During a Patch Load the file to be loaded is corrupted: it may be due to bad CRC or lack of the end of file record.
aaaa bbbb cccc dddd eeee ffff gggg = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to locate the instruction (line of third calling instruction, if any). Used by the designer to locate the instruction (file id of fourth calling instruction, if any).

A30808-X3247-K240-3-7619

419

Outputs OML:BSC
hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = =

Base Station Controller

Used by the designer to locate the instruction (line of fourth calling instruction, if any). Not Used Not Used Not Used Not Used Not Used Not Used Not Used

Originator = 506 SDSM This Failure occours when, during a Download Procedure, the checksum function of a transferred file fails.In this case SDSM task deletes the corrupted files and sets the created object (RSUEXE, RSUSWLH, etc) to DISABLE-FAILED state. To restore the situation, the operator has to trigger again the previous CREATE Object command.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by developer Used by developer Used by developer Used by developer Used by developer Used by developer Used by developer Used by developer Used by developer Used by developer Used by developer Used by developer Used by developer Used by developer Used by developer to identify a nested procedure in the Source Code to identify a nested procedure in the Source Code to identify a nested procedure in the Source Code to identify a nested procedure in the Source Code to identify a nested procedure in the Source Code to identify a nested procedure in the Source Code to identify a nested procedure in the Source Code to identify a nested procedure in the Source Code to identify a nested procedure in the Source Code to identify a nested procedure in the Source Code to identify a nested procedure in the Source Code to identify a nested procedure in the Source Code to identify a nested procedure in the Source Code to identify a nested procedure in the Source Code to identify a nested procedure in the Source Code

##StartSpecProbl##
Specific Problems = 264 INVALID ACCESS TO DATA

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION
420 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Originator = 812 TOSICIOIT It is not possible to access correct data because some values of the logical_ppxx table are corrupted: it is not possible to have the PCU number.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = 0x0a INVALID DUAM NUMBER Current value of the variable source_sys Current value of the variable dest_sys Current value of the variable source_mbx Current value of the variable dest_mbx Current value of the variable sig_type Current value of the variable sig_subtype Current value of the variable object_name Current value of the variable object_number Current value of the variable pcu_number Not used Not used Not used Not used Not used

Originator = 813 TOSICIOOT It is not possible to access TDPC-PPLD or TDPC-PPCC or TDPC-PPXL duam correctly because the 'sys_no' message header reserved field is corrupted: it is not possible to have the duam number.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll = = = = = = = = = = = = 0x0a INVALID DUAM NUMBER Current value of the variable duam_no. Current value of 'source_sys' message header field. Current value of 'dest_sys' message header field. Current value of 'flags' message header field. Current value of 'source_mbx.name' message header field. Current value of 'destination.name' message header field. Current value of 'signal_type' message header field. Current value of 'signal_subtype' message header field. Current value of 'datalen' message header field. Current value of 'sys_no' message header reserved field. 0x01 REGULAR CAPACITY CONFIGURATION 0x02 HIGH CAPACITY CONFIGURATION Not used Not used Not used

mmmm = nnnn = oooo =

A30808-X3247-K240-3-7619

421

Outputs OML:BSC

Base Station Controller

##StartSpecProbl##
Specific Problems = 304 INVALID MESSAGE LENGTH

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 308 MOSICIOIT It is not possible for MPCC to receive a message from a task running on TDPC because some fields of RTE+ message header filled in on TDPC are wrong: it is not possible for MPCC to receive a message from a TDPC task or to send a message out of MPCC system.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = 0x20 LOAD MSG FROM TDPC Current value of the variable datalen not used not used not used not used not used not used not used not used not used not used not used not used not used

Originator = 309 MOSICIOOT It is not possible for MPCC to send a message to a task running on TDPC because some fields of RTE+ message header filled in on MPCC are wrong: it is not possible to send a message to a TDPC task or to send a message out of MPCC system.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = 0x13 MESSAGE TO TDPC. Current value of the variable source_sys. Current value of the variable dest_sys. Current value of the variable flags. Current value of the variable source_mbx. Current value of the variable dest_mbx. Current value of the variable signal_type. Current value of the variable signal_subtype. Current value of the variable datalen. Not used. Not used. Not used. Not used. Not used. Not used.

422

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Originator = 313 MOSICILPD It is not necessary to split the received message into packets in order to send it to LMT remote.
aaaa = bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = Used by the designer as an internal error code; its value is: 000C (message does not need fragmentation). Number of the source code line where error was issued. Size of data field of the message. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

Originator = 319 MOSICIOIR It is not possible for MPCC to receive a message from a task running on TDPC because some fields of RTE+ message header filled in on TDPC are wrong: it is not possible for MPCC to receive a message from TDPC or to send a message out of MPCC system.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = 0x14 MESSAGE FROM TDPC Current value of the variable source_sys Current value of the variable dest_sys Current value of the variable flags Current value of the variable source_mbx Current value of the variable dest_mbx Current value of the variable signal type Current value of the variable signal subtype Current value of the variable datalen not used not used not used not used not used not used

A30808-X3247-K240-3-7619

423

Outputs OML:BSC

Base Station Controller

Originator = 812 TOSICIOIT It is not possible for TDPC to receive a message from a task running on PPLD or PPCC (PPXL) or from a load task running on PCUC (PPXU) because some fields of RTE+ message header filled in on PPLD or PPCC or PCUC (or PPXL or PPXU) are wrong; as a consequence, it is not possible to send a message out of TDPC system.
aaaa = 0x18 BUFF MSG FROM PPLD (or PPXL) 0x17 DB MSG FROM PPLD 0x1a LOAD MSG FROM PPLD (or PPXL) 0x16 BUFF MSG FROM PPCC (or PPXL) 0x15 DB MSG FROM PPCC 0x1b LOAD MSG FROM PPCC 0x1e LOAD MSG FROM PPCU (or PPXU) 0x1f QUEUE MSG FROM PPLD (or PPXL) 0x2b QUEUE MSG FROM PPCC (or PPXL) 0x2d DB MSG FROM PPXL Current value of the variable datalen 0x01 REGULAR_CAPACITY_CONF 0x02 HIGH_CAPACITY_CONF not used not used not used not used not used not used not used not used not used not used not used not used

bbbb = cccc = dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = =

Originator = 813 TOSICIOOT It is not possible to send a message to a task running on PPLD or PPCC or PPCU (or PPXL or PPXU) or MPCC from TDPC, because some fields of RTE+ message header sent to PPXX or MPCC are wrong: it is not possible to send a message to PPXX or MPCC task or send a message out of MPCC system.
aaaa = 0x0f MESSAGE TO PPLD (or PPXL) 0x10 DB MSG TO PPCC (or PPXL) 0x11 BUFF MSG TO PPCC (or PPXL) 0x12 MESSAGE TO MPCC 0x19 MESSAGE TO PPCU (or PPXU) 0x34 RTE OM MSG TO PPXL Current value of the variable source_sys Current value of the variable dest_sys Current value of the variable flags Current value of the variable source_mbx Current value of the variable dest_mbx

bbbb cccc dddd eeee ffff

= = = = =

424

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = = = = = = Current value of the variable signal_type Current value of the variable signal_subtype Current value of the variable datalen 0x01 REGULAR_CAPACITY_CONF 0x02 HIGH_CAPACITY_CONF not used not used not used not used not used

gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

Originator = 819 TOSICIOIR It is not possible for TDPC to receive a message from a task running on PCUC/PPXU or MPCC because some fields of RTE+ message header filled in on PCUC/PPXU or MPCC are wrong: it is not possible for TDPC to receive a message from PCUC/PPXU or MPCC task or to send a message out of TDPC system.
aaaa = 0x14 MESSAGE FROM MPCC 0x1d MSG FROM PCUC TO TDPC 0x2c ERR MSG FROM PPXL Current value of the variable source_sys Current value of the variable dest_sys Current value of the variable flags Current value of the variable source_mbx Current value of the variable dest_mbx Current value of the variable signal type Current value of the variable signal subtype Current value of the variable datalen 0x01 REGULAR_CAPACITY_CONF 0x02 HIGH_CAPACITY_CONF not used not used not used not used not used

bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

= = = = = = = = = = = = = =

Originator = 820 TOSICIOMM It is not possible for TDPC to send a paging test message to a TRX because the length of the message is out of range.
aaaa bbbb cccc dddd = = = = 0x27 MULTI_MSG_TO_TRX Current value of 'datalen' message header field. Current value of 'trxidx' message header field. Current value of 'channel_number' field.

A30808-X3247-K240-3-7619

425

Outputs OML:BSC
eeee = ffff = gggg = hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = Current value of 'paging_group' field. Number of messages successfully sent. 0x01 REGULAR_CAPACITY_CONF 0x02 HIGH_CAPACITY_CONF Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

Base Station Controller

Originator = 951 UOSICIOIT It is not possible for PCUC to receive a message from a task running on GbIC or TDPC because some fields of RTE+ message header sent by a task running on GbIC or TDPC are wrong: it is not possible to receive a message from a GbIC or TDPC task or to send a message out of PCUC system.
aaaa = bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = 0x1c MSG FROM TDPC TO PCUC 0x22 MSG FROM GbIC TO PCUC Current value of the variable source_sys Current value of the variable dest_sys Current value of the variable flags Current value of the variable source_mbx Current value of the variable dest_mbx Current value of the variable signal type Current value of the variable signal subtype Current value of the variable datalen not used not used not used not used not used not used

Originator = 952 UOSICIOOT It is not possible for PCUC to send a message to a task running on TDPC or on GbIC because some fields of RTE+ message header filled in on PCUC are wrong: it is not possible to send a message to a TDPC or GbIC task or to send a message out of PCUC system.
aaaa = bbbb = 0x13 MESSAGE TO TDPC 0x0e MESSAGE TO GbIC Current value of the variable source_sys

426

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = = = = = = = = = = Current value of the variable dest_sys Current value of the variable flags Current value of the variable source_mbx Current value of the variable dest_mbx Current value of the variable signal_type Current value of the variable signal_subtype Current value of the variable datalen Not used Not used Not used Not used Not used Not used

cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

Originator = 980 YOSICIOIT It is not possible for PPXL to receive a message from a task running on TDPC because some fields of RTE+ message header filled in on PPXL are wrong: it is not possible to receive a message from TDPC task or to send a message out of PPXL system.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = 0x2e MSG FROM TDPC TO PPXL Current value of the variable source_sys Current value of the variable dest_sys Current value of the variable flags Current value of the variable source_mbx Current value of the variable dest_mbx Current value of the variable signal type Current value of the variable signal subtype Current value of the variable datalen 0x01 REGULAR_CAPACITY_CONF 0x02 HIGH_CAPACITY_CONF Not used Not used Not used Not used Not used

Originator = 981 YOSICIOOT It is not possible for PPXL to send a message to a task running on TDPC because some fields of RTE+ message header filled in on PPXL are wrong: it is not possible to send a message to a TDPC task or to send a message out of PPXL system.
aaaa bbbb cccc dddd = = = = 0x13 MESSAGE TO TDPC Current value of the variable source_sys Current value of the variable dest_sys Current value of the variable flags

A30808-X3247-K240-3-7619

427

Outputs OML:BSC
eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = Current value of the variable source_mbx Current value of the variable dest_mbx Current value of the variable signal_type Current value of the variable signal_subtype Current value of the variable datalen Not used Not used Not used Not used Not used Not used

Base Station Controller

Originator = 990 NOSICIOIT It is not possible for PPXU to receive a message from a task running on TDPC because some fields of RTE+ message header filled in on PPXU are wrong: it is not possible to receive a message from TDPC task or to send a message out of PPXU system.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = 0x2f MSG FROM TDPC TO PPXU Current value of the variable source_sys Current value of the variable dest_sys Current value of the variable flags Current value of the variable source_mbx Current value of the variable dest_mbx Current value of the variable signal type Current value of the variable signal subtype Current value of the variable datalen 0x01 REGULAR_CAPACITY_CONF 0x02 HIGH_CAPACITY_CONF Not used Not used Not used Not used Not used

Originator = 991 NOSICIOOT It is not possible for PPXU to send a message to a task running on TDPC because some fields of RTE+ message header filled in on PPXU are wrong: it is not possible to send a message to a TDPC task or to send a message out of PPXU system.
aaaa bbbb cccc dddd eeee ffff gggg hhhh = = = = = = = = 0x13 MESSAGE TO TDPC Current value of the variable source_sys Current value of the variable dest_sys Current value of the variable flags Current value of the variable source_mbx Current value of the variable dest_mbx Current value of the variable signal_type Current value of the variable signal_subtype

428

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = = = = Current value of the variable datalen Not used Not used Not used Not used Not used Not used

iiii jjjj kkkk llll mmmm nnnn oooo

##StartSpecProbl##
Specific Problems = 308 INVALID DESTINATION MAILBOX

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 951 UOSICIOIT It is not possible to send a message to a task running on PCUC because the destination field of RTE+ message header is wrong: it is not possible to send a message to a PCUC task or out of PCUC system.
aaaa = bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = 0x0c INVALID ROUTING FROM GbIC 0x0d INVALID ROUTING FROM TDPC Current value of the variable source_sys and dest_sys Current value of the variable flags and priority Current value of the variable source_mbx Current value of the variable dest_mbx Current value of the variable sig_type Current value of the variable sig_subtype Current value of the variable datalen Current value of the variable rsvd[0] e rsvd[1] Current value of the variable rsvd[2] e rsvd[3] Current value of the variable rsvd[4] e rsvd[5] Current value of the variable rsvd[6] e rsvd[7] Current value of the variable rsvd[8] e rsvd[9] Current value of the variable rsvd[10] e rsvd[11] Current value of the first 2 bytes of message data

Originator = 952 UOSICIOOT It is not possible for PCUC to send a message to a task running on TDPC or on GbIC because the destination field of RTE+ message header is wrong: it is not possible to send a message to TDPC or GbIC task or to send a message out of PCUC system.
A30808-X3247-K240-3-7619 429

Outputs OML:BSC
aaaa = bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = 0x07 INVALID ROUTING TO GbIC 0x08 INVALID ROUTING TO TDPC Current value of the variable source_sys and dest_sys Current value of the variable flags and priority Current value of the variable source_mbx Current value of the variable dest_mbx Current value of the variable sig_type Current value of the variable sig_subtype Current value of the variable datalen Current value of the variable rsvd[0] e rsvd[1] Current value of the variable rsvd[2] e rsvd[3] Current value of the variable rsvd[4] e rsvd[5] Current value of the variable rsvd[6] e rsvd[7] Current value of the variable rsvd[8] e rsvd[9] Current value of the variable rsvd[10] e rsvd[11] Current value of the first 2 bytes of message data

Base Station Controller

Originator = 980 YOSICIOIT It is not possible to send a message to a task because the destination field of RTE+ message header is wrong: it is not possible to send a message to a PPXL task or out of PPXL system.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = 0x0d INVALID ROUTING FROM TDPC Current value of the variable source_sys and dest_sys Current value of the variable flags and priority Current value of the variable source_mbx Current value of the variable dest_mbx Current value of the variable sig_type Current value of the variable sig_subtype Current value of the variable datalen Current value of the variable rsvd[0] e rsvd[1] Current value of the variable rsvd[2] e rsvd[3] Current value of the variable rsvd[4] e rsvd[5] Current value of the variable rsvd[6] e rsvd[7] Current value of the variable rsvd[8] e rsvd[9] Current value of the variable rsvd[10] e rsvd[11] Current value of the first 2 bytes of message data

Originator = 981 YOSICIOOT It is not possible for PPXL to send a message to a task running on TDPC because the destination field of RTE+ message header is wrong: it is not possible to send a message to TDPC or to send a message out of PPXL system.
aaaa = bbbb = 0x08 INVALID ROUTING TO TDPC Current value of the variable source_sys and dest_sys

430

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = = = = = = = = = = Current value of the variable flags and priority Current value of the variable source_mbx Current value of the variable dest_mbx Current value of the variable sig_type Current value of the variable sig_subtype Current value of the variable datalen Current value of the variable rsvd[0] e rsvd[1] Current value of the variable rsvd[2] e rsvd[3] Current value of the variable rsvd[4] e rsvd[5] Current value of the variable rsvd[6] e rsvd[7] Current value of the variable rsvd[8] e rsvd[9] Current value of the variable rsvd[10] e rsvd[11] Current value of the first 2 bytes of message data

cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

Originator = 990 NOSICIOIT It is not possible to send a message to a task because the destination field of RTE+ message header is wrong: it is not possible to send a message to a PPXU task or out of PPXU system.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = 0x0d INVALID ROUTING FROM TDPC Current value of the variable source_sys and dest_sys Current value of the variable flags and priority Current value of the variable source_mbx Current value of the variable dest_mbx Current value of the variable sig_type Current value of the variable sig_subtype Current value of the variable datalen Current value of the variable rsvd[0] e rsvd[1] Current value of the variable rsvd[2] e rsvd[3] Current value of the variable rsvd[4] e rsvd[5] Current value of the variable rsvd[6] e rsvd[7] Current value of the variable rsvd[8] e rsvd[9] Current value of the variable rsvd[10] e rsvd[11] Current value of the first 2 bytes of message data

Originator = 991 NOSICIOOT It is not possible for PPXU to send a message to a task running on TDPC because the destination field of RTE+ message header is wrong: it is not possible to send a message to TDPC or to send a message out of PPXU system.
aaaa bbbb cccc dddd eeee = = = = = 0x08 INVALID ROUTING TO TDPC Current value of the variable source_sys and dest_sys Current value of the variable flags and priority Current value of the variable source_mbx Current value of the variable dest_mbx

A30808-X3247-K240-3-7619

431

Outputs OML:BSC
ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = Current value of the variable sig_type Current value of the variable sig_subtype Current value of the variable datalen Current value of the variable rsvd[0] e rsvd[1] Current value of the variable rsvd[2] e rsvd[3] Current value of the variable rsvd[4] e rsvd[5] Current value of the variable rsvd[6] e rsvd[7] Current value of the variable rsvd[8] e rsvd[9] Current value of the variable rsvd[10] e rsvd[11] Current value of the first 2 bytes of message data

Base Station Controller

##StartSpecProbl##
Specific Problems = 333 MEMORY BUFFER CORRUPTED

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 316 MOSICUTBM The message buffer is corrupted.


aaaa = 0x11 - The top of the buffer is corrupted. 0x12 - The bottom of the buffer is corrupted. 0x1f - The current item's header of the list of buffers owned by the task in execution is out of range. 0x20 - The down pointer of the current item of the list of buffers owned by the task in execution is out of range. 0x23 - The value of a pointer in the list of buffers owned by the task in execution is out of range. 0x24 - The value of the pointer to the list of buffers owned by the task in execution is out of range. 0x26 - There are too many buffers owned by the task in execution. If aaaa=0x11 or 0x12, it indicates the name of the running pSOS+ task (least significant word). If aaaa=0x1f, it indicates the head item's value (least significant word) If aaaa=0x20, it indicates the down pointer's value of the current item of the list (least significant word). If aaaa=0x23, it indicates the number of buffers currently owned by the task in execution.. If aaaa=0x24, it indicates the call point of the function which checks the consistency of pointer's value. If aaaa=0x26, it indicates the entry point of the running pSOS+ task (least significant word). If aaaa=0x11 or 0x12, it indicates the name of the running pSOS+ task (most significant word). If aaaa=0x1f, it indicates the head item's value (most significant word) If aaaa=0x20, it indicates the down pointer's value of the current item of the list (most significant word). If aaaa=0x23, it indicates the call point of the function which checks the consistency of pointers' values. If aaaa=0x24, it indicates the pointer's value (least significant word). If aaaa=0x26, it indicates the entry point of the running pSOS+ task (most significant word). If aaaa=0x11 or 0x12, it indicates the entry point of the running pSOS+ task (least significant word). If aaaa=0x1f, it indicates the tail item's value (least significant word) If aaaa=0x20, it indicates the down pointer's value of the current item of the list (most

bbbb =

cccc =

dddd =

432

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
significant word). If aaaa=0x23 and dddd=0x1111, it indicates that the first head or down pointer in the first or middle element of the list is out of range. If aaaa=0x24, it indicates the pointer's value (most significant word). If aaaa=0x26, it indicates the number of buffers currently owned by the task in execution.. If aaaa=0x11 or 0x12, it indicates the entry point of the running pSOS+ task (most significant word). If aaaa=0x1f, it indicates the tail item's value (most significant word) If aaaa=0x23 and eeee=0x2222, it indicates that the last up pointer in the first or middle element of the list is out of range. If aaaa=0x11, it indicates the start address of the operational control area at the beginning of message buffer (least significant word). If aaaa=0x12, it indicates the end address of the message buffer (least significant word). If aaaa=0x1f, it indicates the current item's value (least significant word) If aaaa=0x23 and ffff=0x3333, it indicates that the value of the pointer to the last element of the list is out of range. If aaaa=0x11, it indicates the start address of the operational control area at the beginning of message buffer (most significant word). If aaaa=0x12, it indicates the end address of the message buffer (most significant word). If aaaa=0x1f, it indicates the current item's value (most significant word) If aaaa=0x23 and gggg=0x4444, it indicates that the up pointer in the last element of the list is out of range. If aaaa=0x11 or 0x12, it indicates the current value of the first word of message buffer If aaaa=0x23 and hhhh=0x5555, it indicates that the down pointer in the last element of the list is out of range. If aaaa=0x11 or 0x12, it indicates the current value of the second word of message buffer If aaaa=0x23 and dddd=0x6666, it indicates that the tail pointer in the header of the list is out of range. If aaaa=0x11 or 0x12, it indicates the current value of the third word of message buffer If aaaa=0x11 or 0x12, it indicates the current value of the fourth word of message buffer If aaaa=0x11 or 0x12, it indicates the current value of the fifth word of message buffer If aaaa=0x11 or 0x12, it indicates the current value of the sixth word of message buffer If aaaa=0x11 or 0x12, it indicates the current value of the seventh word of message buffer If aaaa=0x11 or 0x12, it indicates the current value of the eighth word of message buffer

eeee =

ffff =

gggg =

hhhh =

iiii =

jjjj kkkk llll mmmm nnnn oooo

= = = = = =

Originator = 317 MOSICUTMT The message buffer to send is corrupted.


aaaa = bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm = = = = = = = = = = = = 0x11 - The top of the buffer is corrupted. 0x12 - The bottom of the buffer is corrupted. Name of the running pSOS+ task (least significant word). Name of the running pSOS+ task (most significant word). Entry Point of the running pSOS+ task (least significant word). Entry Point of the running pSOS+ task (most significant word). Current value of 'source_sys' message header field. Current value of 'dest_sys' message header field. Current value of 'source_mbx' message header field. Current value of 'dest_mbx' message header field. Current value of 'msg_type' message header field. Current value of 'msg_subtype' message header field. Current value of 'len' message header field. If aaaa=0x11, it indicates the start address of the operational control area at the beginning of message buffer (least significant word). If aaaa=0x12, it indicates the end address of the message buffer (least significant word). If aaaa=0x11, it indicates the start address of the operational control area at the beginning of message buffer (most significant word).

nnnn =

A30808-X3247-K240-3-7619

433

Outputs OML:BSC
oooo =

Base Station Controller

If aaaa=0x12, it indicates the end address of the message buffer (most significant word). If aaaa=0x11, it indicates the current value of 'magic_no' field of the operational control area at the beginning of message buffer (least significant word). If aaaa=0x12, it indicates the current value of 'magic_no' field at the end of message buffer (least significant word).

Originator = 970 XOSICUTBM The message buffer is corrupted.


aaaa = 0x11 - The top of the buffer is corrupted. 0x12 - The bottom of the buffer is corrupted. 0x1f - The current item's header of the list of buffers owned by the task in execution is out of range. 0x20 - The down pointer of the current item of the list of buffers owned by the task in execution is out of range. 0x23 - The value of a pointer in the list of buffers owned by the task in execution is out of range. 0x24 - The value of the pointer to the list of buffers owned by the task in execution is out of range. 0x26 - There are too many buffers owned by the task in execution. If aaaa=0x11, it indicates the start address of the operational control area at the beginning of message buffer (least significant word). If aaaa=0x12, it indicates the end address of the message buffer (least significant word). If aaaa=0x1f, it indicates the head item's value (least significant word) If aaaa=0x20, it indicates the down pointer's value of the current item of the list (least significant word). If aaaa=0x23, it indicates the number of buffers currently owned by the task in execution.. If aaaa=0x24, it indicates the call point of the function which checks the consistency of pointer's value. If aaaa=0x26, its value is zero. If aaaa=0x11, it indicates the start address of the operational control area at the beginning of message buffer (most significant word). If aaaa=0x12, it indicates the end address of the message buffer (most significant word). If aaaa=0x1f, it indicates the head item's value (most significant word) If aaaa=0x20, it indicates the down pointer's value of the current item of the list (most significant word). If aaaa=0x23, it indicates the call point of the function which checks the consistency of pointers' values. If aaaa=0x24, it indicates the pointer's value (least significant word). If aaaa=0x26, its value is zero. If aaaa=0x11 or 0x12, it indicates the current value of the first word of message buffer. If aaaa=0x1f, it indicates the tail item's value (least significant word) If aaaa=0x23 and dddd=0x1111, it indicates that the first head or down pointer in the first or middle element of the list is out of range. If aaaa=0x24, it indicates the pointer's value (most significant word). If aaaa=0x26, it indicates the number of buffers currently owned by the task in execution.. If aaaa=0x11 or 0x12, it indicates the current value of the second word of message buffer If aaaa=0x1f, it indicates the tail item's value (most significant word) If aaaa=0x23 and eeee=0x2222, it indicates that the last up pointer in the first or middle element of the list is out of range. If aaaa=0x11 or 0x12, it indicates the current value of the third word of message buffer If aaaa=0x1f, it indicates the current item's value (least significant word) If aaaa=0x23 and ffff=0x3333, it indicates that the value of the pointer to the last element of the list is out of range. If aaaa=0x11 or 0x12, it indicates the current value of the fourth word of message buffer If aaaa=0x1f, it indicates the current item's value (most significant word) If aaaa=0x23 and gggg=0x4444, it indicates that the up pointer in the last element of the list is out of range. If aaaa=0x11 or 0x12, it indicates the current value of the fifth word of message buffer

bbbb =

cccc =

dddd =

eeee =

ffff =

gggg =

hhhh =

434

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
If aaaa=0x23 and hhhh=0x5555, it indicates that the down pointer in the last element of the list is out of range. If aaaa=0x11 or 0x12, it indicates the current value of the sixth word of message buffer If aaaa=0x23 and dddd=0x6666, it indicates that the tail pointer in the header of the list is out of range. If aaaa=0x11 or 0x12, it indicates the current value of the seventh word of message buffer If aaaa=0x11 or 0x12, it indicates the current value of the eighth word of message buffer If aaaa=0x11 or 0x12, it indicates the current value of the ninth word of message buffer If aaaa=0x11 or 0x12, it indicates the current value of the tenth word of message buffer If aaaa=0x11 or 0x12, it indicates the current value of the eleventh word of message buffer If aaaa=0x11 or 0x12, it indicates the current value of the twelfth word of message buffer

iiii =

jjjj kkkk llll mmmm nnnn oooo

= = = = = =

Originator = 971 XOSICUTMT The message buffer to send is corrupted.


aaaa = bbbb cccc dddd eeee ffff gggg hhhh iiii = = = = = = = = 0x11 - The top of the buffer is corrupted. 0x12 - The bottom of the buffer is corrupted. Current value of 'source_sys' message header field. Current value of 'dest_sys' message header field. Current value of 'source_mbx' message header field. Current value of 'dest_mbx' message header field. Current value of 'msg_type' message header field. Current value of 'msg_subtype' message header field. Current value of 'len' message header field. If aaaa=0x11, it indicates the start address of the operational control area at the beginning of message buffer (least significant word). If aaaa=0x12, it indicates the end address of the message buffer (least significant word). If aaaa=0x11, it indicates the start address of the operational control area at the beginning of message buffer (most significant word). If aaaa=0x12, it indicates the end address of the message buffer (most significant word). If aaaa=0x11, it indicates the current value of 'magic_no' field of the operational control area at the beginning of message buffer (least significant word). If aaaa=0x12, it indicates the current value of 'magic_no' field at the end of message buffer (least significant word). If aaaa=0x11, it indicates the current value of 'magic_no' field of the operational control area at the beginning of message buffer (most significant word). If aaaa=0x12, it indicates the current value of 'magic_no' field at the end of message buffer (most significant word). Not used. Not used. Not used.

jjjj =

kkkk =

llll =

mmmm = nnnn = oooo =

A30808-X3247-K240-3-7619

435

Outputs OML:BSC

Base Station Controller

Specific Problems = 345 INVALID DUAM INDEX

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 308 MOSICIOIT, 812 TOSICIOIT, 951 UOSICIOIT, 980 YOSICIOIT, 990 NOSICIOIT The writing or reading index of the duam reception partition have inconsistent values.
aaaa = 0x30 - The writing index stored in duam is corrupted. 0x31 - The local reading index is corrupted. 0x33 - The value of the next message's index heading the message in duam is different from the one expected. If aaaa=0x30 or 0x31, it indicates the segment part of the address of the duam partition writing index, from which the PPXL card number can be obtained. If aaaa=0x33, it indicates the segment part of the address of the duam partition reading index, from which the PPXL card number can be obtained. If aaaa=0x30 or 0x31, it indicates the offset part of the address of the duam partition writing index, from which the partition number can be obtained. If aaaa=0x33, it indicates the offset part of the address of the duam partition reading index, from which the partition number can be obtained. If aaaa=0x30 or 0x31, it indicates the current value of the writing index stored in duam. If aaaa=0x33, it indicates the current value of the next message's index heading the message in duam. If aaaa=0x30 or 0x31, it indicates the current value of the reading index stored in duam. If aaaa=0x33, it indicates the expected value of the next message's index. If aaaa=0x30 or 0x31, it indicates the current value of the local writing index. If aaaa=0x33, it indicates the message's length as stored in duam before the related message. Current value of local reading index. Not used Not used Not used Not used Not used Not used Not used Not used

bbbb =

cccc =

dddd =

eeee = ffff = gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = =

Originator = 821 TOSICIOMR The writing or reading index of the duam transmission partition for SS7 traffic type messages, used for MSU retrieval, have inconsistent values.
aaaa = bbbb = 0x33 - The value of the next message's index heading the message in duam is different from the one expected. Segment part of the address of the duam partition writing index, from which the PPXL card number can be obtained.

436

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
Offset part of the address of the duam partition writing index, from which the partition number can be obtained. Current value of the next message's index heading the message in duam. Expected value of the next message's index. Message's length as stored in duam before the related message. Current value of local reading index. Not used Not used Not used Not used Not used Not used Not used Not used

cccc = dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = =

A30808-X3247-K240-3-7619

437

Outputs OML:BSC

Base Station Controller

14 ENCLOSURE DOOR OPEN


FAILURE EVENT REPORT: NAME = Probable cause = Specific Problems = Event Type = Event Time = Severity = Trend Indication = Notification Identifier = Correlated Notification Identifier = Related MO = Proposed Repair Actions = Additional Text = Originator = Additional Words =
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo <R.T.D.>

<R.T.D.> <R.T.D.> <see legend> <see legend> <R.T.D.> <see legend> <R.T.D.> <R.T.D.> <displayed only during Alarm Alignment> <R.T.D.> <R.T.D.> <see legend> <R.T.D.> <see legend>

Software Version =

Legend:

Specific Problems = 127 ENCLOSURE DOOR OPEN ALARM

Event Type = ENVIRONMENTAL FAILURE EVENT Severity = MINOR Proposed Repair Actions = 6 SEE THE FORESEEN OPERATING COMPANY REPAIR ACTION

Originator = 4001 MDHACENSA The door of the environment where the system is located has been left open.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll = = = = = = = = = = = = Developer reserved: code line number where error is emitted Error originator where error was detected Reports the Sense Point number to which the temperature sensor is connected (from 0 to 4). Reports the number of seconds to consider the alarm as true (i.e. the alarm must persist the reported number of seconds to take it into account). Reports the current state of all Sense Points. Reports if the alarm was detecetd on the active copy of Mpcc (1if TRUE , 0 if FALSE) Reports if the alarm was detecetd on the standby copy of Mpcc (1if TRUE , 0 if FALSE). Reports the number of the active Mpcc. not used. not used. not used. not used.

438

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
not used. not used. not used.

mmmm = nnnn = oooo =

A30808-X3247-K240-3-7619

439

Outputs OML:BSC

Base Station Controller

17 FILE ERROR
FAILURE EVENT REPORT: NAME = Probable cause = Specific Problems = Event Type = Event Time = Severity = Trend Indication = Notification Identifier = Correlated Notification Identifier = Related MO = Proposed Repair Actions = Additional Text = Originator = Additional Words =
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo <R.T.D.>

<R.T.D.> <R.T.D.> File Error <see legend> <see legend> <R.T.D.> <see legend> <R.T.D.> <R.T.D.> <displayed only during Alarm Alignment> <R.T.D.> <R.T.D.> <see legend> <R.T.D.> <see legend>

Software Version =

Legend:

##StartSpecProbl##
Specific Problems = 170 ERROR IN PREPAIRING FILE

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 2100 CDBMDBFH This error is issued during the preparation of reports file when the task which zipped the file doesn't answer to the caller.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj = = = = = = = = = = Source C line Signal type Not used Not used Not used Not used Not used Not used Not used Not used

440

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = = Not used Not used Not used Not used Not used

kkkk llll mmmm nnnn oooo

Originator = 2222 CDBMDHSA This error is issued when at the end of period of automatic upload, some SCA results still in auto-upload (pending)
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Source C line auto_upload value related to SCA btsmn value related to SCA btsrn value related to SCA Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used

Specific Problems = 216 FILE TOO LONG WARNING

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 318 MOSICUSSC The Upload Server received more bytes than it expected.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction). Used by the designer to locate the instruction (line of second calling instruction). Used by the designer to locate the instruction (file id of third calling instruction). Used by the designer to locate the instruction (line of third calling instruction). Used by the designer to locate the instruction (file id of fourth calling instruction). Used by the designer to locate the instruction (line of fourth calling instruction). number of instance

A30808-X3247-K240-3-7619

441

Outputs OML:BSC
jjjj kkkk llll mmmm nnnn oooo = = = = = = state event buffer size buffer size + message length Not used Not used

Base Station Controller

442

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

18 FIRE DETECTED
FAILURE EVENT REPORT: NAME = Probable cause = Specific Problems = Event Type = Event Time = Severity = Trend Indication = Notification Identifier = Correlated Notification Identifier = Related MO = Proposed Repair Actions = Additional Text = Originator = Additional Words =
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo <R.T.D.>

<R.T.D.> <R.T.D.> Fire Detected <see legend> <see legend> <R.T.D.> <see legend> <R.T.D.> <R.T.D.> <displayed only during Alarm Alignment> <R.T.D.> <R.T.D.> <see legend> <R.T.D.> <see legend>

Software Version =

Legend:

Specific Problems = 126 FIRE DETECTED ALARM

Event Type = ENVIRONMENTAL FAILURE EVENT Severity = CRITICAL Proposed Repair Actions = 6 SEE THE FORESEEN OPERATING COMPANY REPAIR ACTION

Originator = 4001 MDHACENSA Fire in the environment where the system is located has been detected.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll = = = = = = = = = = = = Developer reserved: code line number where error is emitted Error originator where error was detected Reports the Sense Point number to which the temperature sensor is connected (from 0 to 4). Reports the number of seconds to consider the alarm as true (i.e. the alarm must persist the reported number of seconds to take it into account). Reports the current state of all Sense Points. Reports if the alarm was detecetd on the active copy of Mpcc (1if TRUE , 0 if FALSE) Reports if the alarm was detecetd on the standby copy of Mpcc (1if TRUE , 0 if FALSE). Reports the number of the active Mpcc. not used. not used. not used. not used.

A30808-X3247-K240-3-7619

443

Outputs OML:BSC
mmmm = nnnn = oooo = not used. not used. not used.

Base Station Controller

444

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

22 HUMIDITY UNACCEPTABLE
FAILURE EVENT REPORT: NAME = Probable cause = Specific Problems = Event Type = Event Time = Severity = Trend Indication = Notification Identifier = Correlated Notification Identifier = Related MO = Proposed Repair Actions = Additional Text = Originator = Additional Words =
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo <R.T.D.>

<R.T.D.> <R.T.D.> Humidity Unacceptable <see legend> <see legend> <R.T.D.> <see legend> <R.T.D.> <R.T.D.> <displayed only during Alarm Alignment> <R.T.D.> <R.T.D.> <see legend> <R.T.D.> <see legend>

Software Version =

Legend:

Specific Problems = 124 HUMIDITY UNACCEPTABLE ALARM

Event Type = ENVIRONMENTAL FAILURE EVENT Severity = MAJOR Proposed Repair Actions = 6 SEE THE FORESEEN OPERATING COMPANY REPAIR ACTION

Originator = 4001 MDHACENSA The humidity of the environment where the system is located has exceeded the acceptable limit.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk = = = = = = = = = = = Developer reserved: code line number where error is emitted Error originator where error was detected Reports the Sense Point number to which the temperature sensor is connected (from 0 to 4). Reports the number of seconds to consider the alarm as true (i.e. the alarm must persist the reported number of seconds to take it into account). Reports the current state of all Sense Points. Reports if the alarm was detecetd on the active copy of Mpcc (1if TRUE , 0 if FALSE) Reports if the alarm was detecetd on the standby copy of Mpcc (1if TRUE , 0 if FALSE). Reports the number of the active Mpcc. not used. not used. not used.

A30808-X3247-K240-3-7619

445

Outputs OML:BSC
llll mmmm nnnn oooo = = = = not used. not used. not used. not used.

Base Station Controller

446

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

28 LOSS OF FRAME
FAILURE EVENT REPORT: NAME = Probable cause = Specific Problems = Event Type = Event Time = Severity = Trend Indication = Notification Identifier = Correlated Notification Identifier = Related MO = Proposed Repair Actions = Additional Text = Originator = Additional Words =
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo <R.T.D.>

<R.T.D.> <R.T.D.> Loss Of Frame <see legend> <see legend> <R.T.D.> <see legend> <R.T.D.> <R.T.D.> <displayed only during Alarm Alignment> <R.T.D.> <R.T.D.> <see legend> <R.T.D.> <see legend>

Software Version =

Legend:

##StartSpecProbl##
Specific Problems = 195 LOSS OF FRAME ALIGNMENT

Event Type = COMMUNICATION FAILURE EVENT Severity = MAJOR Proposed Repair Actions = 8 CHECK LINE CONFIGURATION ON BOTH SIDE

Originator = 4404 MDHLCSASC The frame alignment has been lost. This can be due by 50% to BSC and by 50% to the network element connected to the line.
aaaa = bbbb = cccc = Developer reserved: code line number where error is emitted Licd type (0=DTLP, 1=QTLP, 2=QTLP V2) LOW BYTE contains the logical licd number (the object which manages a group of PCM lines, defined in the database), HIGH BYTE contains the phisycal licd (hardware card effectively in service). It may be different from the logical licd if the LICDS is providing service (9=spare 0, A=spare 1). Line involved (0-3) Link involved (1=link A, 2=link B) signal absent ais alarm present lfa alarm present

dddd eeee ffff gggg hhhh

= = = = =

A30808-X3247-K240-3-7619

447

Outputs OML:BSC
iiii jjjj kkkk llll mmmm = = = = =

Base Station Controller

nnnn =

oooo =

eer alarm present rai alarm present lca alarm present rnua alarm present LOW BYTE contains : lnua alarm present. HIGH BYTE contains: working mode (DD = double trunk , BB = single trunk ) If LicdType = DTLP then b5 alarm present, it means that the bit no. 5 of the time slot 0 is different from the expected value (1). In some networks of telecommunications it is used to notify the loss of synchronization (timing alarm procedure). For the GSM network however it is generally unused. It is handled only by the DTLP. If LicdType = QTLP V1 or QTLP V2 then alarm causes AA= Pcm Permanent CC = Pcm Micro Interruptions . LOW BYTE contains: txal alarm present, it reveals a wrong parity on the PCM stream transmitted to the LICD by the switching matrix. This signal is transmitted through a bus that is composed, for each LICD, by 4 lines at 8 Mb/s (of which 2 are redunded, and carry the parity signal). This alarm can be induced either by clock problems (due to PLLH), or by some faulted circuit on the switching matrix, or by some fault in the PCM parity checker of the LICD. It is handled only by the QTLP V1. HIGH BYTE contains: type of pcm working mode 24(16h)->PCM24; 32(20h)->PCM32.

##StartSpecProbl##
Specific Problems = 196 LOSS OF FRAME ALIGNMENT ON LINK A

Event Type = COMMUNICATION FAILURE EVENT Severity = MINOR Proposed Repair Actions = 8 CHECK LINE CONFIGURATION ON BOTH SIDE

Originator = 4404 MDHLCSASC The frame alignment has been lost on the link A of the line. This can be due by 50% to BSC and by 50% to the network element connected to the line. This alarm causes a reduction of the redundancy state of the line, and can be issued only for PCM lines configured in duplex.
aaaa = bbbb = cccc = Developer reserved: code line number where error is emitted Licd type (0=DTLP, 1=QTLP, 2=QTLP V2) LOW BYTE contains the logical licd number (the object which manages a group of PCM lines, defined in the database), HIGH BYTE contains the phisycal licd (hardware card effectively in service). It may be different from the logical licd if the LICDS is providing service (9=spare 0, A=spare 1). Line involved (0-3) Link involved (1=link A, 2=link B) signal absent ais alarm present lfa alarm present eer alarm present rai alarm present lca alarm present rnua alarm present LOW BYTE contains : lnua alarm present. HIGH BYTE contains: working mode (DD = double trunk , BB = single trunk ) If LicdType = DTLP then b5 alarm present, it means that the bit no. 5 of the time slot 0 is different from the expected value (1). In some networks of telecommunications it is used to

dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm

= = = = = = = = = =

nnnn =

448

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
notify the loss of synchronization (timing alarm procedure). For the GSM network however it is generally unused. It is handled only by the DTLP. If LicdType = QTLP V1 or QTLP V2 then alarm causes AA= Pcm Permanent CC = Pcm Micro Interruptions . LOW BYTE contains: txal alarm present, it reveals a wrong parity on the PCM stream transmitted to the LICD by the switching matrix. This signal is transmitted through a bus that is composed, for each LICD, by 4 lines at 8 Mb/s (of which 2 are redunded, and carry the parity signal). This alarm can be induced either by clock problems (due to PLLH), or by some faulted circuit on the switching matrix, or by some fault in the PCM parity checker of the LICD. It is handled only by the QTLP V1. HIGH BYTE contains: type of pcm working mode 24(16h)->PCM24; 32(20h)->PCM32.

oooo =

##StartSpecProbl##
Specific Problems = 197 LOSS OF FRAME ALIGNMENT ON LINK B

Event Type = COMMUNICATION FAILURE EVENT Severity = MINOR Proposed Repair Actions = 8 CHECK LINE CONFIGURATION ON BOTH SIDE

Originator = 4404 MDHLCSASC The frame alignment has been lost on the link B of the line. This can be due by 50% to BSC and by 50% to the network element connected to the line. This error causes a reduction of the redundancy state of the line, and can be issued only for PCM lines configured in duplex.
aaaa = bbbb = cccc = Developer reserved: code line number where error is emitted Licd type (0=DTLP, 1=QTLP, 2=QTLP V2) LOW BYTE contains the logical licd number (the object which manages a group of PCM lines, defined in the database), HIGH BYTE contains the phisycal licd (hardware card effectively in service). It may be different from the logical licd if the LICDS is providing service (9=spare 0, A=spare 1). Line involved (0-3) Link involved (1=link A, 2=link B) signal absent ais alarm present lfa alarm present eer alarm present rai alarm present lca alarm present rnua alarm present LOW BYTE contains : lnua alarm present. HIGH BYTE contains: working mode (DD = double trunk , BB = single trunk ) If LicdType = DTLP then b5 alarm present, it means that the bit no. 5 of the time slot 0 is different from the expected value (1). In some networks of telecommunications it is used to notify the loss of synchronization (timing alarm procedure). For the GSM network however it is generally unused. It is handled only by the DTLP. If LicdType = QTLP V1 or QTLP V2 then alarm causes AA= Pcm Permanent CC = Pcm Micro Interruptions . LOW BYTE contains: txal alarm present, it reveals a wrong parity on the PCM stream transmitted to the LICD by the switching matrix. This signal is transmitted through a bus that is composed, for each LICD, by 4 lines at 8 Mb/s (of which 2 are redunded, and carry the LOW parity signal). This alarm can be induced either by clock problems (due to PLLH), or

dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm

= = = = = = = = = =

nnnn =

oooo =

A30808-X3247-K240-3-7619

449

Outputs OML:BSC

Base Station Controller

by some faulted circuit on the switching matrix, or by some fault in the PCM parity checker of the LICD. It is handled only by the QTLP V1. HIGH BYTE contains: type of pcm working mode 24(16h)->PCM24; 32(20h)->PCM32.

##StartSpecProbl##
Specific Problems = 198 LOSS OF CRC ALIGNMENT

Event Type = COMMUNICATION FAILURE EVENT Severity = MAJOR Proposed Repair Actions = 8 CHECK LINE CONFIGURATION ON BOTH SIDE

Originator = 4404 MDHLCSASC The CRC (cyclic redundancy code) alignment has been lost.
aaaa = bbbb = cccc = Developer reserved: code line number where error is emitted Licd type (0=DTLP, 1=QTLP, 2=QTLP V2) LOW BYTE contains the logical licd number (the object which manages a group of PCM lines, defined in the database), HIGH BYTE contains the phisycal licd (hardware card effectively in service). It may be different from the logical licd if the LICDS is providing service (9=spare 0, A=spare 1). Line involved (0-3) Link involved (1=link A, 2=link B) signal absent ais alarm present lfa alarm present eer alarm present rai alarm present lca alarm present rnua alarm present LOW BYTE contains : lnua alarm present. HIGH BYTE contains: working mode (DD = double trunk , BB = single trunk ) If LicdType = DTLP then b5 alarm present, it means that the bit no. 5 of the time slot 0 is different from the expected value (1). In some networks of telecommunications it is used to notify the loss of synchronization (timing alarm procedure). For the GSM network however it is generally unused. It is handled only by the DTLP. If LicdType = QTLP V1 or QTLP V2 then alarm causes AA= Pcm Permanent CC = Pcm Micro Interruptions . LOW BYTE contains: txal alarm present, it reveals a wrong parity on the PCM stream transmitted to the LICD by the switching matrix. This signal is transmitted through a bus that is composed, for each LICD, by 4 lines at 8 Mb/s (of which 2 are redunded, and carry the LOW parity signal). This alarm can be induced either by clock problems (due to PLLH), or by some faulted circuit on the switching matrix, or by some fault in the PCM parity checker of the LICD. It is handled only by the QTLP V1. HIGH BYTE contains: type of pcm working mode 24(16h)->PCM24; 32(20h)->PCM32.

dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm

= = = = = = = = = =

nnnn =

oooo =

##StartSpecProbl##
450 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Specific Problems = 199 LOSS OF CRC ALIGNMENT ON LINK A

Event Type = COMMUNICATION FAILURE EVENT Severity = MINOR Proposed Repair Actions = 8 CHECK LINE CONFIGURATION ON BOTH SIDE

Originator = 4404 MDHLCSASC The CRC (cyclic redundancy code) alignment has been lost on link A. This alarm causes a reduction of the redundancy state of the line, and can be issued only for PCM lines configured in duplex.
aaaa = bbbb = cccc = Developer reserved: code line number where error is emitted Licd type (0=DTLP, 1=QTLP, 2=QTLP V2) LOW BYTE contains the logical licd number (the object which manages a group of PCM lines, defined in the database), HIGH BYTE contains the phisycal licd (hardware card effectively in service). It may be different from the logical licd if the LICDS is providing service (9=spare 0, A=spare 1). Line involved (0-3) Link involved (1=link A, 2=link B) signal absent ais alarm present lfa alarm present eer alarm present rai alarm present lca alarm present rnua alarm present LOW BYTE contains : lnua alarm present. HIGH BYTE contains: working mode (DD = double trunk , BB = single trunk ) If LicdType = DTLP then b5 alarm present, it means that the bit no. 5 of the time slot 0 is different from the expected value (1). In some networks of telecommunications it is used to notify the loss of synchronization (timing alarm procedure). For the GSM network however it is generally unused. It is handled only by the DTLP. If LicdType = QTLP V1 or QTLP V2 then alarm causes AA= Pcm Permanent CC = Pcm Micro Interruptions . LOW BYTE contains: txal alarm present, it reveals a wrong parity on the PCM stream transmitted to the LICD by the switching matrix. This signal is transmitted through a bus that is composed, for each LICD, by 4 lines at 8 Mb/s (of which 2 are redunded, and carry the LOW parity signal). This alarm can be induced either by clock problems (due to PLLH), or by some faulted circuit on the switching matrix, or by some fault in the PCM parity checker of the LICD. It is handled only by the QTLP V1. HIGH BYTE contains: type of pcm working mode 24(16h)->PCM24; 32(20h)->PCM32.

dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm

= = = = = = = = = =

nnnn =

oooo =

##StartSpecProbl##
Specific Problems = 200 LOSS OF CRC ALIGNMENT ON LINK B

Event Type = COMMUNICATION FAILURE EVENT Severity = MINOR Proposed Repair Actions = 8 CHECK LINE CONFIGURATION ON BOTH SIDE

A30808-X3247-K240-3-7619

451

Outputs OML:BSC

Base Station Controller

Originator = 4404 MDHLCSASC The CRC (cyclic redundancy code) alignment has been lost on link B. This alarm causes a reduction of the redundancy state of the line, and can be issued only for PCM lines configured in duplex.
aaaa = bbbb = cccc = Developer reserved: code line number where error is emitted Licd type (0=DTLP, 1=QTLP, 2=QTLP V2) LOW BYTE contains the logical licd number (the object which manages a group of PCM lines, defined in the database), HIGH BYTE contains the phisycal licd (hardware card effectively in service). It may be different from the logical licd if the LICDS is providing service (9=spare 0, A=spare 1). Line involved (0-3) Link involved (1=link A, 2=link B) signal absent ais alarm present lfa alarm present eer alarm present rai alarm present lca alarm present rnua alarm present LOW BYTE contains : lnua alarm present. HIGH BYTE contains: working mode (DD = double trunk , BB = single trunk ) If LicdType = DTLP then b5 alarm present, it means that the bit no. 5 of the time slot 0 is different from the expected value (1). In some networks of telecommunications it is used to notify the loss of synchronization (timing alarm procedure). For the GSM network however it is generally unused. It is handled only by the DTLP. If LicdType = QTLP V1 or QTLP V2 then alarm causes AA= Pcm Permanent CC = Pcm Micro Interruptions . LOW BYTE contains: txal alarm present, it reveals a wrong parity on the PCM stream transmitted to the LICD by the switching matrix. This signal is transmitted through a bus that is composed, for each LICD, by 4 lines at 8 Mb/s (of which 2 are redunded, and carry the LOW parity signal). This alarm can be induced either by clock problems (due to PLLH), or by some faulted circuit on the switching matrix, or by some fault in the PCM parity checker of the LICD. It is handled only by the QTLP V1. HIGH BYTE contains: type of pcm working mode 24(16h)->PCM24; 32(20h)->PCM32.

dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm

= = = = = = = = = =

nnnn =

oooo =

##StartSpecProbl##
Specific Problems = 208 SLIP ALARM ON LINK A

Event Type = COMMUNICATION FAILURE EVENT Severity = MINOR Proposed Repair Actions = 24 CHANGE SYNC SOURCE OR TUNE THE PLLH

Originator = 4404 MDHLCSASC A slip alarm has occurred on the trunk A of the line. This means that the misalignment between the received and transmitted PCM frames has caused some frame to be lost or duplicated, because the elastic buffer is full. This alarm can occur if the network elements (BTS, BSC and TRAU) are not synchronized between them. The slip alarm is filtered according to CR 541: it is issued if 3 slips are detected in an hour, and it is cleared if no slips at all are detected in an hour.
452 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
Developer reserved: code line number where error is emitted Licd type (0=DTLP, 1=QTLP V1, 2=QTLP V2) LOW BYTE contains the logical licd number (the object which manages a group of PCM lines, defined in the database), HIGH BYTE contains the phisycal licd (hardware card effectively in service). It may be different from the logical licd if the LICDS is providing service (9=spare 0, A=spare 1). Line involved (0-3) Link involved (1=link A, 2=link B, 3=both links) No. of SLIPs that have been detected (according to CR 541 , this number should be 3, accordingly to the SLIP management on BTSE) Observation time, in seconds, used in the SLIP filtering alghoritm (again for CR 541, it should be 3600) PCM working mode (24 => PCM24; 32 => PCM32) Working mode (DD = double trunk , BB = single trunk ) not used not used not used not used not used not used

aaaa = bbbb = cccc =

dddd = eeee = ffff = gggg = hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = =

##StartSpecProbl##
Specific Problems = 209 SLIP ALARM ON LINK B

Event Type = COMMUNICATION FAILURE EVENT Severity = MINOR Proposed Repair Actions = 24 CHANGE SYNC SOURCE OR TUNE THE PLLH

Originator = 4404 MDHLCSASC A slip alarm has occurred on the trunk B of the line. This means that the misalignment between the received and transmitted PCM frames has caused some frame to be lost or duplicated, because the elastic buffer is full. This alarm can occur if the network elements (BTS, BSC and TRAU) are not synchronized between them. The slip alarm is filtered according to CR 541: it is issued if 3 slips are detected in an hour, and it is cleared if no slips at all are detected in an hour.
aaaa = bbbb = cccc = Developer reserved: code line number where error is emitted Licd type (0=DTLP, 1=QTLP V1, 2=QTLP V2) LOW BYTE contains the logical licd number (the object which manages a group of PCM lines, defined in the database), HIGH BYTE contains the phisycal licd (hardware card effectively in service). It may be different from the logical licd if the LICDS is providing service (9=spare 0, A=spare 1). Line involved (0-3) Link involved (1=link A, 2=link B, 3=both links) No. of SLIPs that have been detected (according to CR 541 , this number should be 3, accordingly to the SLIP management on BTSE) Observation time, in seconds, used in the SLIP filtering alghoritm (again for CR 541, it should be 3600) PCM working mode (24 => PCM24; 32 => PCM32) Working mode (DD = double trunk , BB = single trunk ) not used

dddd = eeee = ffff = gggg = hhhh = iiii = jjjj =

A30808-X3247-K240-3-7619

453

Outputs OML:BSC
kkkk llll mmmm nnnn oooo = = = = = not used not used not used not used not used

Base Station Controller

##StartSpecProbl##
Specific Problems = 284 NOTIFIED LOSS OF FRAME ALIGNMENT

Event Type = COMMUNICATION FAILURE EVENT Severity = MAJOR Proposed Repair Actions = 15 CHECK CABLES, CONNECTIONS, LINE QUALITY

Originator = 4400 MDHLCDCDE, 4754 TDHTRDCMS Error notified by TRAU towards the BSC on PCMA/PCMS objects. See TRAU error manual at error LOSS_OF_FRAME_ALIGNMENT.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual.

##StartSpecProbl##
Specific Problems = 285 NOTIFIED LOSS OF CRC ALIGNMENT

Event Type = COMMUNICATION FAILURE EVENT Severity = MAJOR Proposed Repair Actions = 15 CHECK CABLES, CONNECTIONS, LINE QUALITY

Originator = 4400 MDHLCDCDE, 4754 TDHTRDCMS

454

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Error notified by TRAU towards the BSC on PCMS/PCMA objects. See TRAU error manual at error LOSS_OF_CRC_ALIGNMENT.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual.

##StartSpecProbl##
Specific Problems = 293 NOTIFIED LOSS OF FRAME ALIGNMENT ON LINK A

Event Type = COMMUNICATION FAILURE EVENT Severity = MINOR Proposed Repair Actions = 15 CHECK CABLES, CONNECTIONS, LINE QUALITY

Originator = 4400 MDHLCDCDE, 4754 TDHTRDCMS Error notified by TRAU towards the BSC on PCMS/PCMA objects. See TRAU error manual at error LOSS_OF_FRAME_ALIGNMENT_ON_LINK_A.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual.

A30808-X3247-K240-3-7619

455

Outputs OML:BSC

Base Station Controller

##StartSpecProbl##
Specific Problems = 294 NOTIFIED LOSS OF FRAME ALIGNMENT ON LINK B

Event Type = COMMUNICATION FAILURE EVENT Severity = MINOR Proposed Repair Actions = 15 CHECK CABLES, CONNECTIONS, LINE QUALITY

Originator = 4400 MDHLCDCDE, 4754 TDHTRDCMS Error notified by TRAU towards the BSC on PCMS/PCMA objects. See TRAU error manual at error LOSS_OF_FRAME_ALIGNMENT_ON_LINK_B.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual.

##StartSpecProbl##
Specific Problems = 295 NOTIFIED LOSS OF CRC ALIGNMENT ON LINK A

Event Type = COMMUNICATION FAILURE EVENT Severity = MINOR Proposed Repair Actions = 15 CHECK CABLES, CONNECTIONS, LINE QUALITY

Originator = 4400 MDHLCDCDE, 4754 TDHTRDCMS Error notified by TRAU towards the BSC on PCMS/PCMA objects. See TRAU error manual at error LOSS_OF_CRC_ALIGNMENT_ON_LINK_A.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii = = = = = = = = = See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual.

456

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = = = See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual.

jjjj kkkk llll mmmm nnnn oooo

Specific Problems = 296 NOTIFIED LOSS OF CRC ALIGNMENT ON LINK B

Event Type = COMMUNICATION FAILURE EVENT Severity = MINOR Proposed Repair Actions = 15 CHECK CABLES, CONNECTIONS, LINE QUALITY

Originator = 4400 MDHLCDCDE, 4754 TDHTRDCMS Error notified by TRAU towards the BSC on PCMS/PCMA objects. See TRAU error manual at error LOSS_OF_CRC_ALIGNMENT_ON_LINK_B.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual. See TRAU error manual.

A30808-X3247-K240-3-7619

457

Outputs OML:BSC

Base Station Controller

32 OUT OF MEMORY
FAILURE EVENT REPORT: NAME = Probable cause = Specific Problems = Event Type = Event Time = Severity = Trend Indication = Notification Identifier = Correlated Notification Identifier = Related MO = Proposed Repair Actions = Additional Text = Originator = Additional Words =
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

<R.T.D.> <R.T.D.> Out Of Memory <see legend> <see legend> <R.T.D.> <see legend> <R.T.D.> <R.T.D.> <displayed only during Alarm Alignment> <R.T.D.> <R.T.D.> <see legend> <R.T.D.> <see legend>

Software Version =

<R.T.D.>

Legend:

##StartSpecProbl##
Specific Problems = 039 FULL INIT REQUESTED

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 4701 TDHBFDCDB The error occurs if the DH could not enqueue the procedure in progress.
aaaa = code module line

458

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = = = = = = = = = = = intrnal error code (dh_gs.h, dbcadhex.h) Btsm number Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used

bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

##StartSpecProbl##
Specific Problems = 045 MEMORY NOT AVAILABLE

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 305 MOSICILEM A buffer allocation needed to send an alarm request to IXLT fails.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = used by designers to identify checkpoint. identity of the task instance. not used not used not used not used not used not used not used not used not used not used not used not used not used

A30808-X3247-K240-3-7619

459

Outputs OML:BSC

Base Station Controller

Originator = 316 MOSICUTBM, 970 XOSICUTBM This error occurs when it isn't possible to add data buffer to the requesting task.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = 0x1D - Request of a buffer failed. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

Originator = 2000 MDATABASE A buffer allocation for a message or a memory allocation for internal operation fails.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = line file identifier in which error occurs not used not used not used not used not used not used not used not used not used not used not used not used not used Note: for the corrispondence between the displayed numbers and the file identifiers, see ANNEX C.

Originator = 2100 CDBMDBFH A buffer allocation for sending a message fails.


aaaa = bbbb = cccc = Source line Not used Not used

460

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = = = = = = = = = Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used

dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

Originator = 2222 CDBMDHSA A buffer allocation for sending a message fails.


aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Source C line Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used

Originator = 2600 TDATABASE A buffer allocation for the response to updating message from MPCC fails.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk = = = = = = = = = = = not used not used not used not used not used not used not used not used not used not used not used

A30808-X3247-K240-3-7619

461

Outputs OML:BSC
llll mmmm nnnn oooo = = = = not used not used not used not used

Base Station Controller

Originator = 3130 MSMSHPIRM This error indicates that Status Manager must enqueue a request in DEFERRED list but there are no buffers available.The request cant be executed.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Source line Action Object mnemonic Object Unit address[0] Object Unit address[1] Object Unit address[2] Object Unit address[3] Not used Not used Not used Not used Not used Not used Not used Not used

Originator = 3144 MSMSHPCSO No entry available in internal MSceTbl table used to handle State Changed Event information.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Source line Action Not used Not used Not used Object mnemonic Object unit address[0] Object unit address[1] Object unit address[2] Object unit address[3] Target Object mnemonic Target Object unit address[0] Target Object unit address[1] Target Object unit address[2] Target Object unit address[3]

462

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Originator = 4305 MDH40IOSC The DK40 Device Handler task cant process an event because the memory allocated has been exhausted
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction). Used by the designer to locate the instruction (file id of second calling instruction). Used by the designer to locate the instruction (file id of third calling instruction). Used by the designer to locate the instruction (file id of third calling instruction). Used by the designer to locate the instruction (file id of fourth calling instruction). Used by the designer to locate the instruction (file id of fourth calling instruction). Used by the designer to identify the task status Used by the designer to identify the task status Used by the designer to identify the task status Used by the designer to identify the task status Used by the designer to identify the task status Used by the designer to identify the task status Used by the designer to identify the task status

Originator = 5001 CPM_IMSI_ORIGINATOR A buffer allocation for a message or a memory allocation for internal operation, fails. All related additional info are developer oriented and useful for debugging activity
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Module that generates the error. Source code line of the module that generates the error. Internal use Internal use Internal use Internal use Internal use Internal use Internal use Internal use Internal use Internal use Internal use Internal use Internal use

A30808-X3247-K240-3-7619

463

Outputs OML:BSC

Base Station Controller

Originator = 5002 CPM_CTR_ORIGINATOR A buffer allocation for a message or a memory allocation for internal operation fails All related additional info are developer oriented and useful for debugging activity .
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Module that generates the error. Source code line of the module that generates the error. Internal use Internal use Internal use Internal use Internal use Internal use Internal use Internal use Internal use Internal use Internal use Internal use Internal use

Originator = 5100 CPM_PCUC_ORIGINATOR A buffer allocation for a message or a memory allocation for internal operation fails All related additional info are developer oriented and useful for debugging activity .
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Module that generates the error. Source code line of the module that generates the error. Internal use Internal use Internal use Internal use Internal use Internal use Internal use Internal use Internal use Internal use Internal use Internal use Internal use

464

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Originator = 5500 CPM_TDPC_ORIGINATOR A buffer allocation for a message or a memory allocation for internal operation fails All related additional info are developer oriented and useful for debugging activity .
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Module that generates the error. Source code line of the module that generates the error. Internal use Internal use Internal use Internal use Internal use Internal use Internal use Internal use Internal use Internal use Internal use Internal use Internal use

Originator = 10103 MBACW A buffer allocation for a message or a memory allocation for internal operation fails.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Module that generates the error. Source code line of the module that generates the error. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

Originator = 10103 MBACW


A30808-X3247-K240-3-7619 465

Outputs OML:BSC

Base Station Controller

A buffer allocation for a message or a memory allocation for internal operation fails.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Module that generates the error. Source code line of the module that generates the error. Return value of the failed function call Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

Originator = 10105 - MBAMF A buffer allocation for a message or a memory allocation for internal operation fails.
aaaa = a3a2a1a0 = a3a2 : mediation_direction a3a2 0 0: CMIP_TO_BII 0 1: BII_TO_CMIP a1a0 : source_file_id (id file whose exception occurs) source_file_line_number c3c2 : context_kind (it fixes the meaning of the following bytes) c3c2 0 1: CBAMF_MOC_MOI_CTX 0 2: CBAMF_MOC_MOI_MEDIATION_CTX 0 3: CBAMF_MESSAGE_CTX 0 4: CBAMF_CONTAINER_CTX c1c0 : message_source_task (from IO_HDR) d3d2 : message_destination_task (from IO_HDR)) d1d0 : message_job_number (from IO_HDR) message_operation_code (from IO_HDR) if CBAMF_MESSAGE_CTX f3f2 = cmip_service 0 0: CBAMF_CREATE_ARGUMENT 0 1: CBAMF_CREATE_RESULT 0 2: CBAMF_DELETE_ARGUMENT 0 3: CBAMF_DELETE_RESULT 0 4: CBAMF_SET_ARGUMENT 0 5: CBAMF_SET_RESULT 0 6: CBAMF_GET_ARGUMENT 0 7: CBAMF_GET_RESULT 0 8: CBAMF_CREATE_INFO 0 9: CBAMF_SET_INFO 0 A: CBAMF_ACTION_ARGUMENT 0 B: CBAMF_ACTION_RESULT 0 C: CBAMF_PROCESSING_FAILURE 0 D: CBAMF_EVENT_REPORT

bbbb = cccc =

dddd =

eeee = ffff =

466

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
f1 f0 = number_of_responses (0..CBAMF_MAX_BII_MESSAGES)

gggg =

if CBAMF_MOC_MOI_CTX g3g2g1g0f3f2f1f0 = class descriptor reference if CBAMF_CONTAINER_CTX g3g2g1g0f3f2f1f0 = reference to the attribute translator

hhhh = iiii =

if CBAMF_MOC_MOI_CTX

h3h2h1h0 = MOC

if CBAMF_MOC_MOI_CTX i3i2i1i0 = address[0] of MOI if CBAMF_CONTAINER_CTX i3i2i1i0h3h2h1h0 = a BII-attribute value if CBAMF_MOC_MOI_CTX j3j2j1j0 = address[1] of MOI if CBAMF_CONTAINER_CTX j3j2 = current_subitem (items counter) j1 j0 = cmip_container_type 0 0: CBAMF_ATTRIBUTE_LIST_CT 0 1: CBAMF_CMIP_SEQUENCE_CT 0 2: CBAMF_CMIP_SEQUENCE_OF_AD_CT 0 3: CBAMF_CMIP_SEQUENCE_OF_NATIVE_CT if CBAMF_MOC_MOI_CTX k3k2k1k0 = address[2] of MOI if CBAMF_MESSAGE_CTX g3g2g1g0h3h2h1h0i3i2i1i0j3j2j1j0k1k0 = IO_HDR first response if CBAMF_CONTAINER_CTX k1k0 = bii_container_type k1k0 0 4: CBAMF_T_MESSAGE_CT 0 5: CBAMF_T_CONFIGURATION_MESSAGE_CT 0 6: CBAMF_T_TAGGED_MESSAGE_CT 0 7: CBAMF_ASB_MESSAGE_CT 0 8: CBAMF_ASB_CONFIGURATION_MESSAGE_CT 0 9: CBAMF_BII_SEQUENCE_CT 0 A: CBAMF_BII_CHOICE_CT 0 B: CBAMF_BII_SEQUENCE_OF_CT if CBAMF_CONTAINER_CTX and (k1k0 = 04 or 05 or 06 or 07 or 08) k3k2 : current_message (BII-messages counter) if CBAMF_MOC_MOI_CTX l3l2l1l0 = address[3] of MOI if CBAMF_MOC_MOI_CTX m3m2m1m0 = address[4] of MOI if CBAMF_CONTAINER_CTX and (k1k0 = 04 or 05 or 06 or 07 or 08) m3m2m1m0l3l2l1l0 = reference to message_translator if CBAMF_CONTAINER_CTX and (k1k0 = 0B) m3m2m1m0l3l2l1l0k3k2 = space for the SequenceOf element value if CBAMF_CONTAINER_CTX and (k1k0 = 04 or 05 or 06 or 07 or 08) n3n2 = current offset in body_message n1n0 = msg_operation_code if CBAMF_CONTAINER_CTX and (k1k0 = 09 or 0A) n3n2n1n0m3m2m1m0l3l2l1l0k3k2 = space for the Sequence field value if CBAMF_CONTAINER_CTX and (k1k0 = 0B) n3n2 = number of SequenceOf elements n1n0 = phisical size of the SequenceOf element if CBAMF_MOC_MOI_CTX n3n2n1n0o3o2o1o0 = ASB_MEID if CBAMF_MESSAGE_CTX k3k2l3l2l1l0m3m2m1m0n3n2n1n0o3o2o1o0 = IO_HDR second response if CBAMF_CONTAINER_CTX and (j1j0 = 00) o3o2 = current_attribute (Attributes counter) o1o0 = Attribute List length if CBAMF_CONTAINER_CTX and (j1j0 = 02 or 03)

jjjj =

kkkk =

llll = mmmm =

nnnn =

oooo =

A30808-X3247-K240-3-7619

467

Outputs OML:BSC
o3o2 = number of SequenceOf elements o1o0 = number of used SequenceOf elements

Base Station Controller

Originator = 10106 MBAMA A buffer allocation for a message or a memory allocation for internal operation fails.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Module that generates the error. Source code line of the module that generates the error. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

Originator = 10107 MBAAW A buffer allocation for a message or a memory allocation for internal operation fails.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Module that generates the error. Source code line of the module that generates the error. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

468

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Originator = 10107 MBAAW A buffer allocation for a message or a memory allocation for internal operation fails.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Module that generates the error. Source code line of the module that generates the error. Return value of the failed function call Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

##StartSpecProbl##
Specific Problems = 048 ERROR MESSAGES DISCARDED

Event Type = QUALITY OF SERVICE FAILURE EVENT Severity = MINOR Proposed Repair Actions = 1 NO ACTION

Originator = 3002 MSMARECTH, 3502 TSMARECTH Error collector throttling task has received from error collector on MPCC or TDPC an INDUCED failure event, but the table on which this type of messages are stored is busy, so the input message is lost.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm = = = = = = = = = = = = = Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

A30808-X3247-K240-3-7619

469

Outputs OML:BSC
nnnn = oooo = Not used. Not used.

Base Station Controller

Originator = 3010 MSMAREPDE Error Collector delay task on MPCC can't store all INDUCED fault messages buffers sent from this time because the table that manages them is busy.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Source code line where the error happended (designer oriented). not used not used not used not used not used not used not used not used not used not used not used not used not used not used

##StartSpecProbl##
Specific Problems = 049 MEMORY OVERFLOW

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 5 SEE THE PROPOSED ACTION IN THE MANUAL

Originator = 410 MOSKNMSEH, 901 TOSKNMSEH, 950 UOSKNMSEH, 982 YOSKNMSEH, 992 NOSKNMSEH This error is generated every time it isn't possible to grant a require of memory.
aaaa = 0x11 0x12 0x13 not used not used not used not used not used not used MEM_OVF MEM_BAD_ADDR MSG_OVF

bbbb cccc dddd eeee ffff gggg

= = = = = =

470

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = = = = = not used not used not used not used not used not used not used not used

hhhh iiii jjjj kkkk llll mmmm nnnn oooo

Originator = 505 MSDSMCTMA The Compression task needs more memory than the available.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to lacate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to lacate the instruction (line of third calling instruction). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any). Number of file. Not used. Not used. Not used. Not used. Not used. Not used.

Originator = 5500 CPM_TDPC_ORIGINATOR This error is generated when there is an internal data area violation.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm = = = = = = = = = = = = = Used by the designer as an internal error code; its value is a. Source module that generates the error; its value is 4. Source code line of the module that generates the error. Scanner number. Internal use. not used not used not used not used not used not used not used not used

A30808-X3247-K240-3-7619

471

Outputs OML:BSC
nnnn = oooo = not used not used

Base Station Controller

Originator = 10108 MQ3CB A data structure is corrupted


aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = (developer oriented) source module (developer oriented) number of source module line not used not used not used not used not used not used not used not used not used not used not used not used not used

##StartSpecProbl##
Specific Problems = 050 DYNAMIC MEMORY POOL OVERFLOW

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 410 MOSKNMSEH, 901 TOSKNMSEH, 950 UOSKNMSEH, 982 YOSKNMSEH, 992 NOSKNMSEH This error is generated every time it isn't possible to grant a require of blocks of memory from the dynamic memory pools.
aaaa = 0 POOL_TR, 1 POOL_TC, 2 POOL_MB, 3 POOL_SEM, 4 POOL_STK, 5 POOL_HDR, 6 POOL_DATA_MSG, 7 POOL_MSG_0, 8 POOL_MSG_1, 9 POOL_MSG_2, 0x0A POOL_MSG_3 number of overflows in the pool overflow threshold

bbbb = cccc =

472

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = = = = = = = = = consecutive overflow number consecutive overflow threshold initialization threshold (low word) initialization threshold (high word) not used not used not used not used not used not used not used not used

dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

##StartSpecProbl##
Specific Problems = 060 AP MEMORY MESSAGE FAULT

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 7100 TL3RDALL Buffer pool not available during handover or assignment procedure, the message was discarded.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Process Identifier (see annex D for more details) Process Istance Process State Not Used Process Source Line Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used

##StartSpecProbl##
Specific Problems = 091 AP NO MEMORY

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

A30808-X3247-K240-3-7619

473

Outputs OML:BSC

Base Station Controller

Originator = 7100 TL3RDALL Buffer pool not available, the message is discarded.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Process Identifier (see annex D for more details) Process Instance Process State Not Used Process Source Line Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used

Originator = 7200 PKINRMMRMD, 7201 PKINOMMGMD, 7202 PKINGBMGBD, 7203 PKINABMABD, 7204 PKPMUTBUTC, 7205 PKPMUTBUTM, 7206 PKPMDTBDTC, 7207 PKPMDTBDTM, 7208 PKTSPRMPCH, 7209 PKTSPRMPPM, 7210 IPKTSPRMPFR, 7211 PKTSABBPDS, 7212 PKTSABBTBS, 7213 PKUTBMBUPR, 7214 PKUTBMBBVM, 7215 PKUTBMBGPG, 7216 PKUTBMBLLM, 7217 PKUTBMBLLR, 7218 PKUTBMBGOV, 7219 PKUTGEMGER, 7220 PKUTTGBTGM, 7221 PKUTTGBTBM, 7222 PKGBICOH, 7223 PKGBICSIGIH, 7224 PKGBICDATIH, 7225 PKTDPCRMIH, 7226 PKTDPCOMIH, 7227 PKTDPCOH, 7228 PKABICIH. No buffer is available to store a message or a RLC block.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Process State. Process Instance. EDOS Message Code. Process Source Line. Procedure Module Originator. Procedure Module Line. Involved pool. Not used. Not used. Not used. Not used. Not used. Not used. Not used. PPCU/PPXU involved (1st byte) and Process Sending Message (2nd byte).

474

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Originator = 8200 PKINRMMRMD, 8201 PKINOMMGMD, 8202 PKINGBMGBD, 8203 PKINABMABD, 8204 PKPMUTBUTC, 8205 PKPMUTBUTM, 8206 PKPMDTBDTC, 8207 PKPMDTBDTM, 8208 PKTSPRMPCH, 8209 PKTSPRMPPM, 8210 IPKTSPRMPFR, 8211 PKTSABBPDS, 8212 PKTSABBTBS, 8213 PKUTBMBUPR, 8214 PKUTBMBBVM, 8215 PKUTBMBGPG, 8216 PKUTBMBLLM, 8217 PKUTBMBLLR, 8218 PKUTBMBGOV, 8219 PKUTGEMGER, 8220 PKUTTGBTGM, 8221 PKUTTGBTBM, 8222 PKGBICOH, 8223 PKGBICSIGIH, 8224 PKGBICDATIH, 8225 PKTDPCRMIH, 8226 PKTDPCOMIH, 8227 PKTDPCOH, 8228 PKABICIH. No buffer is available to store a message or a RLC block.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Process State. Process Instance. EDOS Message Code. Process Source Line. Procedure Module Originator. Procedure Module Line. Involved pool. Not used. Not used. Not used. Not used. Not used. Not used. Not used. PPCU/PPXU involved (1st byte) and Process Sending Message (2nd byte).

##StartSpecProbl##
Specific Problems = 114 MEMT DUAM OVERFLOW

Event Type = PROCESSING FAILURE EVENT Severity = MAJOR Proposed Repair Actions = 1 NO ACTION

Originator = 309 MOSICIOOT The DUAM of TDPC is full: the MPCC output task (TASK_I_O) cannot write the DUAM.
aaaa bbbb cccc dddd eeee ffff gggg hhhh = = = = = = = = not used not used not used not used not used not used not used not used

A30808-X3247-K240-3-7619

475

Outputs OML:BSC
iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = not used not used not used not used not used not used not used

Base Station Controller

Originator = 813 TOSICIOOT The DUAM of TDPC is full: the TDPC output task (TASK_I_O) cannot write the DUAM.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = not used not used not used not used not used not used not used not used not used not used not used not used not used not used not used

##StartSpecProbl##
Specific Problems = 232 DYNAMIC MEMORY POOL OVERFLOW UPPINIT

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 410 MOSKNMSEH, 901 TOSKNMSEH, 950 UOSKNMSEH, 982 YOSKNMSEH, 992 NOSKNMSEH This error is generated when the number of DYNAMIC MEMORY POOL OVERFLOW errors has reached the upper threshold. It is required a FULL initialization.
aaaa = 0 1 2 3 4 5 6 POOL_TR, POOL_TC, POOL_MB, POOL_SEM, POOL_STK, POOL_HDR, POOL_DATA_MSG,

476

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
7 POOL_MSG_0, 8 POOL_MSG_1, 9 POOL_MSG_2, 0x0A POOL_MSG_3 number of overflows in the pool overflow threshold consecutive overflow number consecutive overflow threshold initialization threshold (low word) initialization threshold (high word) not used not used not used not used not used not used not used not used

bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

= = = = = = = = = = = = = =

##StartSpecProbl##
Specific Problems = 311 DYNAMIC MEMORY POOL OVERFLOW LOWINIT

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 410 MOSKNMSEH, 901 TOSKNMSEH, 950 UOSKNMSEH, 982 YOSKNMSEH, 992 NOSKNMSEH This error is generated when the number of DYNAMIC MEMORY POOL OVERFLOW errors has reached the lower threshold. It is required a TASK PRIME initialization.
aaaa = 0 POOL_TR, 1 POOL_TC, 2 POOL_MB, 3 POOL_SEM, 4 POOL_STK, 5 POOL_HDR, 6 POOL_DATA_MSG, 7 POOL_MSG_0, 8 POOL_MSG_1, 9 POOL_MSG_2, 0x0A POOL_MSG_3 number of overflows in the pool overflow threshold consecutive overflow number consecutive overflow threshold initialization threshold (low word) initialization threshold (high word) not used not used not used not used not used

bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll

= = = = = = = = = = =

A30808-X3247-K240-3-7619

477

Outputs OML:BSC
mmmm = nnnn = oooo = not used not used not used

Base Station Controller

##StartSpecProbl##
Specific Problems = 312 MEMORY OVERFLOW LOWINIT

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 5 SEE THE PROPOSED ACTION IN THE MANUAL

Originator = 410 MOSKNMSEH, 901 TOSKNMSEH, 950 UOSKNMSEH, 982 YOSKNMSEH, 992 NOSKNMSEH This error is generated when the number of unsatisfied memory requests has reached the lower threshold. It requires a TASK PRIME initialization.
aaaa = 0x11 0x12 0x13 not used not used not used not used not used not used not used not used not used not used not used not used not used not used MEM_OVF MEM_BAD_ADDR MSG_OVF

bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

= = = = = = = = = = = = = =

##StartSpecProbl##
Specific Problems = 313 MEMORY OVERFLOW UPPINIT

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 5 SEE THE PROPOSED ACTION IN THE MANUAL

Originator = 410 MOSKNMSEH, 901 TOSKNMSEH, 950 UOSKNMSEH, 982 YOSKNMSEH, 992 NOSKNMSEH

478

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

This error is generated when the number of unsatisfied memory requests has reached the upper threshold. It requires a FULL initialization.
aaaa = 0x11 0x12 0x13 not used not used not used not used not used not used not used not used not used not used not used not used not used not used MEM_OVF MEM_BAD_ADDR MSG_OVF

bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

= = = = = = = = = = = = = =

A30808-X3247-K240-3-7619

479

Outputs OML:BSC

Base Station Controller

46

SOFTWARE ERROR
<R.T.D.> <R.T.D.> Software Error <see legend> <see legend> <R.T.D.> <see legend> <R.T.D.> <R.T.D.> <displayed only during Alarm Alignment> <R.T.D.> <R.T.D.> <see legend> <R.T.D.> <see legend>
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo <R.T.D.>

FAILURE EVENT REPORT: NAME = Probable cause = Specific Problems = Event Type = Event Time = Severity = Trend Indication = Notification Identifier = Correlated Notification Identifier = Related MO = Proposed Repair Actions = Additional Text = Originator = Additional Words =

Software Version =

Legend:

##StartSpecProbl##
Specific Problems = 001 COMMAND FULL INITIALIZATION REQUIRED

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 2000 MDATABASE Failed notification of a command to Status Handler or to Device Handler or to Performance Measurement Note:For the corrispondence between the displayed numbers and the file identifiers, see ANNEX C.
aaaa bbbb cccc dddd eeee ffff gggg = = = = = = = source code line where the error was called file identifier in which the error occur Not used. Not used. Not used. Not used. Not used.

480

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = = = = = Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

hhhh iiii jjjj kkkk llll mmmm nnnn oooo

Originator = 4200 MDHNWABAF A severe inconsistency is possible to exist in the network database, due to an abort occurred while the network device handler task was active. This error is also called if the abort routine of network is aborted on its turn.
aaaa = bbbb = source code line where the error was called if its value is 0XAB, an abort of network has been aborted; if it is 0XDB, there is probably an unrecoverable data base inconsistency. The value of this flag discriminates the meaning of some of next other info's (see eeee-gggg) if bbbb=0XDB, it is the value of an internal SW variable indicating the task state (there is an inconsistency if it is greater than 9); if bbbb=0XAB, it is not used if bbbb=0XDB, it is the signal type of the message that was being processed when the abort occurred; if bbbb=0XAB, it is not used like ffff, but it indicates the sub-type of the message. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

cccc = dddd = eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = =

Originator = 4701 TDHBFDCDB The error occurs when the procedures for performing a reconfiguration of specified TRXs or when the procedure to stop trx hopping fails.
aaaa = bbbb = Line of module where the Error Collector call is Internal error code (dh_gs.h) ERR_DATA_OVERFLOW (EC6C)

A30808-X3247-K240-3-7619

481

Outputs OML:BSC

Base Station Controller

cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

= = = = = = = = = = = = =

BTS Number or BTSM Number Old TRX Number New TRX Number Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used

##StartSpecProbl##
Specific Problems = 009 FILE TRANSFER ABORTED BY NETWORK ELEMENT

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 124 MOSSDNDDL0 A BTSE has aborted the download because is no longer able to support it.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to locate the instruction (line of third calling instruction, if any). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any). NE whose download has failed. Not used Not used Not used Not used Not used Not used

482

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Originator = 125 MOSSDNDDL1 A TRAU has aborted the download because is no longer able to support it.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to locate the instruction (line of third calling instruction, if any). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any). NE whose download has failed. Not used Not used Not used Not used Not used Not used

Originator = 314 MOSICILSH A BSC has aborted the transfer of symbolic names file to the requesting LMT.
aaaa = Used by the designer as an internal error code; its value can be: - 0002 (error reading file); - 0003 (unexpected file size). Number of the source code line where error was issued. Job number value of I/O header. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

= = = = = = = = = = = = = =

Originator = 318 MOSICUSSC

A30808-X3247-K240-3-7619

483

Outputs OML:BSC

Base Station Controller

The Upload Server received a Load Data Abort message.


aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to lacate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to lacate the instruction (line of third calling instruction). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any). Number of process. State. Current event. Not used. Not used. Not used. Not used.

##StartSpecProbl##
Specific Problems = 010 FILE TRANSFER FAILED ON NETWORK ELEMENT

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 124 MOSSDNDDL0 A BTSE has notified that the download of the file is failed.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to locate the instruction (line of third calling instruction, if any). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any). NE whose download has failed. Failure cause (Nack Cause). Not used Not used Not used Not used Not used

484

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Originator = 125 MOSSDNDDL1 A TRAU has notified that the download of the file is failed.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to locate the instruction (line of third calling instruction, if any). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any). NE whose download has failed. Failure cause (Nack Cause). Not used. Not used. Not used. Not used. Not used.

##StartSpecProbl##
Specific Problems = 011 FILE TRANSFER REFUSED BY NETWORK ELEMENT

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 124 MOSSDNDDL0 A BTSE has notified that is not able to support the download.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to locate the instruction (line of third calling instruction, if any). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any). NE whose download has failed. Failure cause (Nack Cause). Not used Not used Not used Not used Not used

A30808-X3247-K240-3-7619

485

Outputs OML:BSC

Base Station Controller

Originator = 125 MOSSDNDDL1 A TRAU has notified that is not able to support the download
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to locate the instruction (line of third calling instruction, if any). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any). NE whose download has failed. Failure cause (Nack Cause). Not used. Not used. Not used. Not used. Not used.

##StartSpecProbl##
Specific Problems = 012 STATUS MANAGER DATABASE NOT ALIGNED

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 5 SEE THE PROPOSED ACTION IN THE MANUAL

Originator = 2000 MDATABASE The error is issued in COMMAND MODE, when the operator enters a DELETE command from LMT, if the DBL or DBC updating failed and the Status Manager realignment procedure fails. Note: For the corrispondence between the displayed numbers and the file identifiers, see ANNEX C.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm = = = = = = = = = = = = = line. file identifier. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

486

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
Not used. Not used

nnnn = oooo =

##StartSpecProbl##
Specific Problems = 015 GENERIC SOFTWARE ERROR

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 305 MOSICILEM One of the task instances that collects IXLT error reports was no more running; an audit procedure has detect it.
aaaa = bbbb = cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = used by designer to identify code checkpoint. task instance identity; it may assume value 0 or 1 according to the IXLT copy that the task interfaces. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

Originator = 506 MSDSM This error occours when: case1-The Rsu object under test is not valid, or the procedure of creation of an absolute meid returns unsuccessful or, more generally, in a decision task appens a value not expected. case2-A No Instance Free of a DB or of a SW object ( RSUPCH, RSUEXE,etc) is occurred.
A30808-X3247-K240-3-7619 487

Outputs OML:BSC

Base Station Controller

In this case a recovery action is performed with a complete delete of SW object on MPCC disk (if the involved obj is SW) or only the RSUEXE-0 is freed (if the involved obj is a DB obj).
aaaa = bbbb = cccc = Used in case2 to identify the type of problem (0x666=>rebuild problem in bring-up) Used by the developer, in case2 , to identify the source line code Used only in case2 to identify the type of error: -0x01=DB error -0x02=SW error Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used

dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

= = = = = = = = = = = =

Originator = 510 MOSIWROMA,512 MOSIWRORE,515 MOSIWMEMA,516 MOSIWMEMI,517 MOSIWMEST,518 MOSIWMEAL,519 MOSIWMETE, An errorCollector function is called when Operating System Interworking task is unable to retrieve network Element software version.
aaaa = bbbb = Source code line Used by the designer to indicate the Error description -GET_NE_SVR_FAILED. Occurred when fossd_get_running_ne_svr , called by Interworking ,returns an unsuccessful result Used by the designer to indicate the source_sys Used by the designer to indicate the dest_sys Used by the designer to indicate the flags Used by the designer to indicate the source_mbx Used by the designer to indicate the destination Used by the designer to indicate the signal_type Used by the designer to indicate the signal_subtype Used by the designer to indicate the datalen Used by the designer to indicate the operationcode Used by the designer to indicate the message_type Not used Not used Not used

cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

= = = = = = = = = = = = =

Originator = 600 MSDBACTDA, 603 MSDBACTMA, 604 MSDBACTIA, 605 MSDBACTPA,


488 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

606 MSDBACTTA This error is emitted when a processor controller automata is in a wrong state or when a bad parameter is passed to set state function.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction). Used by the designer to locate the instruction (line of second calling instruction). Used by the designer to locate the instruction (file id of third calling instruction). Used by the designer to locate the instruction (line of third calling instruction). Used by the designer to locate the instruction (file id of fourth calling instruction). Used by the designer to locate the instruction (line of fourth calling instruction). Used by the designer to indicate the processor type. Used by the designer to indicate the wrong state. Not used. Not used. Not used. Not used. Not used.

Originator = 10105 - MBAMF A buffer allocation for a message or a memory allocation for internal operation fails.
aaaa = a3a2a1a0 = a3a2 : mediation_direction a3a2 0 0: CMIP_TO_BII 0 1: BII_TO_CMIP a1a0 : source_file_id (id file whose exception occurs) source_file_line_number c3c2 : context_kind (it fixes the meaning of the following bytes) c3c2 0 1: CBAMF_MOC_MOI_CTX 0 2: CBAMF_MOC_MOI_MEDIATION_CTX 0 3: CBAMF_MESSAGE_CTX 0 4: CBAMF_CONTAINER_CTX c1c0 : message_source_task (from IO_HDR) d3d2 : message_destination_task (from IO_HDR)) d1d0 : message_job_number (from IO_HDR) message_operation_code (from IO_HDR) if CBAMF_MESSAGE_CTX f3f2 = cmip_service 0 0: CBAMF_CREATE_ARGUMENT 0 1: CBAMF_CREATE_RESULT 0 2: CBAMF_DELETE_ARGUMENT 0 3: CBAMF_DELETE_RESULT 0 4: CBAMF_SET_ARGUMENT 0 5: CBAMF_SET_RESULT 0 6: CBAMF_GET_ARGUMENT 0 7: CBAMF_GET_RESULT 0 8: CBAMF_CREATE_INFO 0 9: CBAMF_SET_INFO 0 A: CBAMF_ACTION_ARGUMENT 0 B: CBAMF_ACTION_RESULT 0 C: CBAMF_PROCESSING_FAILURE 0 D: CBAMF_EVENT_REPORT

bbbb = cccc =

dddd = eeee = ffff =

A30808-X3247-K240-3-7619

489

Outputs OML:BSC

Base Station Controller

f1 f0 = number_of_responses (0..CBAMF_MAX_BII_MESSAGES) gggg = if CBAMF_MOC_MOI_CTX g3g2g1g0f3f2f1f0 = class descriptor reference if CBAMF_CONTAINER_CTX g3g2g1g0f3f2f1f0 = reference to the attribute translator if CBAMF_MOC_MOI_CTX h3h2h1h0 = MOC if CBAMF_MOC_MOI_CTX i3i2i1i0 = address[0] of MOI if CBAMF_CONTAINER_CTX i3i2i1i0h3h2h1h0 = a BII-attribute value if CBAMF_MOC_MOI_CTX j3j2j1j0 = address[1] of MOI if CBAMF_CONTAINER_CTX j3j2 = current_subitem (items counter) j1 j0 = cmip_container_type 0 0: CBAMF_ATTRIBUTE_LIST_CT 0 1: CBAMF_CMIP_SEQUENCE_CT 0 2: CBAMF_CMIP_SEQUENCE_OF_AD_CT 0 3: CBAMF_CMIP_SEQUENCE_OF_NATIVE_CT if CBAMF_MOC_MOI_CTX k3k2k1k0 = address[2] of MOI if CBAMF_MESSAGE_CTX g3g2g1g0h3h2h1h0i3i2i1i0j3j2j1j0k1k0 = IO_HDR first response if CBAMF_CONTAINER_CTX k1k0 = bii_container_type k1k0 0 4: CBAMF_T_MESSAGE_CT 0 5: CBAMF_T_CONFIGURATION_MESSAGE_CT 0 6: CBAMF_T_TAGGED_MESSAGE_CT 0 7: CBAMF_ASB_MESSAGE_CT 0 8: CBAMF_ASB_CONFIGURATION_MESSAGE_CT 0 9: CBAMF_BII_SEQUENCE_CT 0 A: CBAMF_BII_CHOICE_CT 0 B: CBAMF_BII_SEQUENCE_OF_CT if CBAMF_CONTAINER_CTX and (k1k0 = 04 or 05 or 06 or 07 or 08) k3k2 : current_message (BII-messages counter) if CBAMF_MOC_MOI_CTX l3l2l1l0 = address[3] of MOI if CBAMF_MOC_MOI_CTX m3m2m1m0 = address[4] of MOI if CBAMF_CONTAINER_CTX and (k1k0 = 04 or 05 or 06 or 07 or 08) m3m2m1m0l3l2l1l0 = reference to message_translator if CBAMF_CONTAINER_CTX and (k1k0 = 0B) m3m2m1m0l3l2l1l0k3k2 = space for the SequenceOf element value if CBAMF_CONTAINER_CTX and (k1k0 = 04 or 05 or 06 or 07 or 08) n3n2 = current offset in body_message n1n0 = msg_operation_code if CBAMF_CONTAINER_CTX and (k1k0 = 09 or 0A) n3n2n1n0m3m2m1m0l3l2l1l0k3k2 = space for the Sequence field value if CBAMF_CONTAINER_CTX and (k1k0 = 0B) n3n2 = number of SequenceOf elements n1n0 = phisical size of the SequenceOf element if CBAMF_MOC_MOI_CTX n3n2n1n0o3o2o1o0 = ASB_MEID if CBAMF_MESSAGE_CTX k3k2l3l2l1l0m3m2m1m0n3n2n1n0o3o2o1o0 = IO_HDR second response if CBAMF_CONTAINER_CTX and (j1j0 = 00) o3o2 = current_attribute (Attributes counter) o1o0 = Attribute List length if CBAMF_CONTAINER_CTX and (j1j0 = 02 or 03) o3o2 = number of SequenceOf elements o1o0 = number of used SequenceOf elements

hhhh = iiii =

jjjj =

kkkk =

llll = mmmm =

nnnn =

oooo =

490

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Originator = 10108 - MQ3CB The CBC Finite State Machine is in an incongruent state. The current operation is aborted and the CBC FSM is reset. aaaa = designer oriented : it identifies the source module bbbb = designer oriented : it identifies the line number within the source module
cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = designer oriented designer oriented

designer oriented designer oriented designer oriented designer oriented designer oriented designer oriented designer oriented designer oriented designer oriented designer oriented designer oriented

##StartSpecProbl##
Specific Problems = 019 UNABLE TO RUN TEST

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 9000 MDGDMPIPR Normally, when a TEST REQUEST cannot be performed, the command is rejected by a NACK answer with the proper nack cause. When the command to be rejected is one previously enqueued, no NACK answer can be sent because the test was accepted in the enqueing phase with the ack message; so this alarm is generated together with the test result, to inform the operator about the cause of the test execution failure.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll = = = = = = = = = = = = <source line> < error cause> < instance> not used not used not used not used not used not used not used not used not used

A30808-X3247-K240-3-7619

491

Outputs OML:BSC
mmmm = nnnn = oooo = not used not used not used

Base Station Controller

##StartSpecProbl##
Specific Problems = 020 WRONG CONNECTION REQUEST

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 4203 DHNWDCUF The SN16/SN64/SNAP is the switching matrix through which all the time slots of the BSC are switched, i.e. time slots used for Abis/Asub traffic channels, LAPD, SS7L, etc. For example, when a traffic call is set up, a connection is established in the switching matrix between an Abis time slot and an Asub time slot. If this error message is generated, it means that some SW entity of the BSC has requested to set up or to release a connection between two time slots, but the state of the 2 timeslots is not consistent with this request. This can happen if a connection set up has been attempted, and one of the 2 channels to be allocated is not idle. It is also generated if a connection release has been requested for 2 channels which are already idle or which are not connected between themselves. Therefore the operation is rejected, because the inconsistency is considered major. In other cases instead the operation is accepted anyway: in these cases, the error "WRONG CONNECTION REQUEST" is generated (see in this manual). The decision whether to accept or to reject the operation depends on the priority that is assigned to the different connections that could be lost serving the request: in particular, the connections used by LAPD, SS7L, X25, NUC are more important than the connection used for the traffic calls, and in case of conflict the latter are sacrificed. In case of conflict between traffic calls, the new connection is refused, but also the existing connection is erased, in order to "clean" the state of the involved time slots. NOTE: in case of processor switch (MPCC or TDPC), for example due to power crash, it is possible that some messages coming from Call Processing are lost, due to the task abort occurred; the corresponding traffic calls are dropped in this case. This causes the misalignment between the database of Call Processing and the state of the network connections in the switching matrix, and the present warning message can appear on LMT, even a certain time later than the time of the processor switch. However, once the inconsistent state of the time slots has been detected, the state of the switching matrix is realigned to the database of Call Processing, and from now on the state of these time slots is correct.
aaaa = bbbb = (designer oriented) source line code where the error is issued Request type: 0=connection establishment (for new traffic call, or creation of LAPD/SS7 L/NUC/FRL); 1=internal hand over; 2=connection release request (for traffic call release, or for deletion of LAPD/SS7L/NUC/FRL);

492

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
0xDDDD=switch of PPLD Length of the channels to be connected or released (In no. of bits: 1=8 Kb/s; 2=16 Kb/s; 8= 64 Kb/s) Type of the first channel (for traffic connections, this is always the terrestrial channel): 0x5555=Circuit of PPCC or PPLD (for signalling channels); 0xAAAA=Channel of LICD 0xAA55=Omal channel (from IXLT) 0xFFAA=Channel of a PCU (valid starting from release BR5.5) 0x5A5A=Reverse idle code inserted (used for HSCSD) 0xAAFF=NUC channel 0xA5A5=Idle channel 1st coordinate of the first channel: if dddd=0x5555, no. of PPXX (0-14=PPLD; 15,16= PPCC 0,1) if dddd=0xAAAA, no. of LICD (high byte) and of PCM circuit (low byte) if dddd=0xAA55,0xA5A5,0xAAFF,0x5A5A not meaningful (0xFFFF) 2nd coordinate of the first channel: if dddd=0x5555, no. of circuit of PPXX if dddd=0xAAAA, no. of the 1st bit of the channel in the 2 Mb/s line(8-255) if dddd=0xAA55,0xA5A5, not meaningful (0xFF) coordinates of the channel that has been found connected to (dddd-ffff), with the same conventions as dddd-ffff. The channel type, however, can assume also the value 0x55AA, which means that the sub-channels which are found connected to (dddd-ffff) do not constitute a self-consistent channel (for example, some sub-channels are connected, and other are idle). This can happen of course only for channels long more than 1 bit. coordinates of the channel that has been found connected to (dddd-ffff), with the same conventions as dddd-ffff. The channel type, however, can assume also the value 0x55AA, which means that the sub-channels which are found connected to (dddd-ffff) do not constitute a self-consistent channel (for example, some sub-channels are connected, and other are idle). This can happen of course only for channels long more than 1 bit. coordinates of the channel that has been found connected to (dddd-ffff), with the same conventions as dddd-ffff. The channel type, however, can assume also the value 0x55AA, which means that the sub-channels which are found connected to (dddd-ffff) do not constitute a self-consistent channel (for example, some sub-channels are connected, and other are idle). This can happen of course only for channels long more than 1 bit. coordinates of the other channel to be connected, with the same conventions of dddd-ffff. For traffic connections, this is always the radio channel. coordinates of the other channel to be connected, with the same conventions of dddd-ffff. For traffic connections, this is always the radio channel. coordinates of the other channel to be connected, with the same conventions of dddd-ffff. For traffic connections, this is always the radio channel. coordinates of the channel that has been found connected to jjjj-llll. coordinates of the channel that has been found connected to jjjj-llll. coordinates of the channel that has been found connected to jjjj-llll.

cccc = dddd =

eeee =

ffff =

gggg =

hhhh =

iiii =

jjjj = kkkk = llll = mmmm = nnnn = oooo =

##StartSpecProbl##
Specific Problems = 021 CONNECTION REQUEST REJECTED

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 4203 DHNWDCUF The SN16/SN64/SNAP is the switching matrix through which all the time slots of the BSC are switched, i.e. time slots used for Abis/Asub traffic channels, LAPD, SS7L, etc. For example, when a traffic call is set up, a connection is established in the switching matrix between an Abis time slot and an Asub time slot.
A30808-X3247-K240-3-7619 493

Outputs OML:BSC

Base Station Controller

If this error message is generated, it means that some SW entity of the BSC has requested to set up or to release a connection between two time slots, but the state of the 2 timeslots is not consistent with this request. This can happen if a connection set up has been attempted, and one of the 2 channels to be allocated is not idle. It is also generated if a connection release has been requested for 2 channels which are already idle or which are not connected between themselves. Nevertheless, the connection request is processed anyway, because it is considered a minor inconsistency. In other cases instead the operation is rejected: in these cases, the error "CONNECTION REQUEST REJECTED" is generated (see in this manual). The decision whether to accept or to reject the operation depends on the priority that is assigned to the different connections that could be lost serving the request: in particular, the connections used by LAPD, SS7L, X25, NUC are more important than the connection used for the traffic calls, and in case of conflict the latter are sacrificed. NOTE: in case of processor switch (MPCC or TDPC), for example due to power crash, it is possible that some messages coming from Call Processing are lost, due to the task abort occurred; the corresponding traffic calls are dropped in this case. This causes the misalignment between the database of Call Processing and the state of the network connections in the switching matrix, and the present warning message can appear on LMT, even a certain time later than the time of the processor switch. However, once the inconsistent state of the time slots has been detected, the state of the switching matrix is realigned to the database of Call Processing, and from now on the state of these time slots is correct.
aaaa = bbbb = (designer oriented) source line code where the error is issued Request type: 0=connection establishment (for new traffic call, or creation of LAPD/SS7L/NUC/FRL); 1=internal hand over; 2=connection release request (for traffic call release, or for deletion of LAPD/SS7L/NUC/FRL); 0xDDDD=switch of PPLD Length of the channels to be connected or released (In no. of bits: 1=8 Kb/s; 2=16 Kb/s; 8= 64 Kb/s) Type of the first channel (for traffic connections, this is always the terrestrial channel): 0x5555=Circuit of PPCC or PPLD (for signalling channels); 0xAAAA=Channel of LICD 0xAA55=Omal channel (from IXLT) 0xFFAA=Channel of a PCU (valid starting from release BR5.5) 0x5A5A=Reverse idle code inserted (used for HSCSD) 0xAAFF=NUC channel 0xA5A5=Idle channel 1st coordinate of the first channel: if dddd=0x5555, no. of PPXX (0-14=PPLD; 15,16= PPCC 0,1) if dddd=0xAAAA, no. of LICD (high byte) and of PCM circuit (low byte) if dddd=0xAA55,0xA5A5,0xAAFF,0x5A5A not meaningful (0xFFFF) 2nd coordinate of the first channel: if dddd=0x5555, no. of circuit of PPXX if dddd=0xAAAA, no. of the 1st bit of the channel in the 2 Mb/s line(8-255) if dddd=0xAA55,0xA5A5, not meaningful (0xFF) coordinates of the channel that has been found connected to (dddd-ffff), with the same conventions as dddd-ffff. The channel type, however, can assume also the value 0x55AA, which means that the sub-channels which are found connected to (dddd-ffff) do not constitute a self-consistent channel (for example, some sub-channels are connected, and other are idle). This can happen of course only for channels long more than 1 bit. coordinates of the channel that has been found connected to (dddd-ffff), with the same conventions as dddd-ffff. The channel type, however, can assume also the value 0x55AA, which means that the sub-channels which are found connected to (dddd-ffff) do not constitute a self-consistent channel (for example, some sub-channels are connected, and other are idle). This can happen of course only for channels long more than 1 bit. coordinates of the channel that has been found connected to (dddd-ffff), with the same conventions as dddd-ffff. The channel type, however, can assume also the value 0x55AA, which means that the sub-channels which are found connected to (dddd-ffff) do not constitute a self-consistent channel (for example, some sub-channels are connected, and

cccc = dddd =

eeee =

ffff =

gggg =

hhhh =

iiii =

494

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
other are idle). This can happen of course only for channels long more than 1 bit. coordinates of the other channel to be connected, with the same conventions of dddd-ffff. For traffic connections, this is always the radio channel. coordinates of the other channel to be connected, with the same conventions of dddd-ffff. For traffic connections, this is always the radio channel. coordinates of the other channel to be connected, with the same conventions of dddd-ffff. For traffic connections, this is always the radio channel. coordinates of the channel that has been found connected to jjjj-llll. coordinates of the channel that has been found connected to jjjj-llll. coordinates of the channel that has been found connected to jjjj-llll.

jjjj = kkkk = llll = mmmm = nnnn = oooo =

##StartSpecProbl##
Specific Problems = 035 MAILBOX NOT ALLOCATED ERROR

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 317 MOSICUTMT, 971 XOSICUTMT This error occurs if there isn't a valid relationship logical name - physical identity for a specified mailbox.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = 0x1C - Physical mailbox identity request failed. Logical mailbox identifier Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

Originator = 2000 MDATABASE The error occurs if it is impossible a mailbox creation. Note: For the correspondence between the displayed numbers and the file identifiers, see
A30808-X3247-K240-3-7619 495

Outputs OML:BSC

Base Station Controller

ANNEX C.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = line file identifier in which the error occurs not used not used not used not used not used not used not used not used not used not used not used not used not used

Originator = 2600 TDATABASE The error occurs if it is not possible a mailbox creation.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = not used not used not used not used not used not used not used not used not used not used not used not used not used not used not used

Originator = 4305 MDH40IOSC The mailbox of the DK40 Device Handler cant be allocated.
aaaa bbbb cccc dddd eeee ffff gggg hhhh = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction). Used by the designer to locate the instruction (file id of second calling instruction). Used by the designer to locate the instruction (file id of third calling instruction). Used by the designer to locate the instruction (file id of third calling instruction). Used by the designer to locate the instruction (file id of fourth calling instruction). Used by the designer to locate the instruction (file id of fourth calling instruction).

496

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = = = = Used by the designer to identify the task status Used by the designer to identify the task status Used by the designer to identify the task status Used by the designer to identify the task status Used by the designer to identify the task status Used by the designer to identify the task status Used by the designer to identify the task status

iiii jjjj kkkk llll mmmm nnnn oooo

Originator = 4843 MDHIXDCUF0 During an RTE message transmission, the mailbox for the answer can't be created.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = BSC mnemonic. the signal type of the message to be transmitted not used not used not used not used not used not used not used not used not used not used not used not used not used

##StartSpecProbl##
Specific Problems = 036 UNSUCCESSFUL RESPONSE FROM STATUS MANAGER ERROR

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 2000 MDATABASE The error occurs if, after sending a message to SM, arrives no response or failed response. Note. For the correspondence between the displayed numbers and the file identifiers, see ANNEX C.
aaaa = bbbb = cccc = line file identifier in which the error occurs not used

A30808-X3247-K240-3-7619

497

Outputs OML:BSC
dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = not used not used not used not used not used not used not used not used not used not used not used not used

Base Station Controller

Originator = 4098 MDHPCSAMA Unsuccessful response from a Status Manager function. There might be a data base corruption.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = NUMERIC VALUE (designer use only) Line in the code where the error took place not used not used not used not used not used not used not used not used not used not used not used not used not used

##StartSpecProbl##
Specific Problems = 037 SPARE TO PRIME INITIALIZATION

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 410 MOSKNMSEH, 901 TOSKNMSEH, 950 UOSKNMSEH, 982 YOSKNMSEH, 992 NOSKNMSEH A sequence of a Spare Task Initializations in a too short interval. The level of the
498 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

initialization is upgraded to Task Prime.


aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = 0x23 not used not used not used not used not used not used not used not used not used not used not used not used not used not used SPARE2TIME

##StartSpecProbl##
Specific Problems = 038 PRIME TO FULL INITIALIZATION

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 410 MOSKNMSEH, 901 TOSKNMSEH, 950 UOSKNMSEH, 982 YOSKNMSEH, 992 NOSKNMSEH A sequence of a Task Prime Initializations in a too short interval. The level of the initialization is upgraded to Full.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = 0x22 RTE+ internal code error (for developer's use) Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used

A30808-X3247-K240-3-7619

499

Outputs OML:BSC

Base Station Controller

##StartSpecProbl##
Specific Problems = 046 MESSAGE DISCARDED

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 3142 MSMSHPCHC This error indicates that there are no buffer available to enqueue the command in HOLD list. So Status Manager replaces the last system command enqueued with the new system request.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Source line Action of command in progres on the managed object. Action of system command removed from HOLD queue. Action of new system command inserteded in HOLD queue. Number of commands in HOLD state Mnemonic Unit address[0] Unit address[1] Unit address[2] Unit address[3] not used not used not used not used not used

Originator = 4305 MDH40IOSC The DK40 Device Handler is trying to process en event which isnt handled in the current state
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction). Used by the designer to locate the instruction (file id of second calling instruction). Used by the designer to locate the instruction (file id of third calling instruction). Used by the designer to locate the instruction (file id of third calling instruction). Used by the designer to locate the instruction (file id of fourth calling instruction). Used by the designer to locate the instruction (file id of fourth calling instruction). Used by the designer to identify the task status Used by the designer to identify the task status Used by the designer to identify the task status Used by the designer to identify the task status Used by the designer to identify the task status Used by the designer to identify the task status Used by the designer to identify the task status

500

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Originator = 5000 CPM_MPCC_ORIGINATOR This error message is issued when some reports stored in internal buffer are lost. All related additional info are developer oriented and useful for debugging activity
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Module that generates the error. Source code line of the module that generates the error. This field is not used or it indicates number of reports lost. This field is not used or it indicates the size of reports lost in word. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use.

Originator = 5100 CPM_PCUC_ORIGINATOR This error message is issued when some reports stored in internal buffer are lost. All related additional info are developer oriented and useful for debugging activity
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Source module that generates the error Source code line of the module that generates the error. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use.

A30808-X3247-K240-3-7619

501

Outputs OML:BSC

Base Station Controller

Originator = 5500 CPM_TDPC_ORIGINATOR This error message is issued when an internal or a BTSE report failed. All related additional info are developer oriented and useful for debugging activity
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Source module that generates the error Source code line of the module that generates the error. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use.

Originator = 7100 TL3RDALL This error is output when a Block message received contains a wrong Cause.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Process Identifier (see annex D for more details) Process Instance Process State Not Used Process Source Line not used not used not used not used not used not used not used not used not used not used

502

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Originator = 9002 MDGDMOUPR Diagnostic Manager has received a result phase but this phase number is not correct. Probably this phase has not been found running or is not one to be executed.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = <source line> < DGWRONGMSG - 0x3> < phases to be executed > < phase number received > not used not used not used not used not used not used not used not used not used not used not used

Originator = 10100 MQ3US A message received by the Q3 stack task is invalid.


aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = designer oriented: it identifies the source module designer oriented : it identifies the line number within the source module not used not used not used not used not used not used designer oriented: it identifies the type of the discarded message not used not used not used not used not used not used

A30808-X3247-K240-3-7619

503

Outputs OML:BSC

Base Station Controller

Originator = 10100 MQ3US A message received by the Q3 stack task is invalid.


aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = designer oriented: it identifies the source module designer oriented : it identifies the line number within the source module not used not used not used not used not used not used designer oriented: it identifies the type of the discarded message not used designer oriented : it identifies a field of the discarded message not used not used not used not used

Originator = 10108 MQ3CB A message is too long. The current operation is aborted
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = designer oriented: it identifies the source module designer oriented : it identifies the line number within the source module not used not used not used not used not used not used not used not used not used not used not used not used not used

##StartSpecProbl##
Specific Problems = 051 DELETED CURRENT TASK

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

504

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Originator = 410 MOSKNMSEH, 901 TOSKNMSEH, 950 UOSKNMSEH, 982 YOSKNMSEH, 992 NOSKNMSEH A task or a scan work function caused an exception and the system deletes it; if the Entry point is equal to zero the activity which caused the interrupt is a scan work function.A RTE System Info Report is related to this message. For more details, please refers to ANNEX E.
aaaa = 0x14 0x1E 0x2D DEL CURR TSK DEL CURR SWF DEL CURR TSK PSOS

bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

= = = = = = = = = = = = = =

Task Entry Point (offset 32bit) Task Entry Point (offset 32bit) Interrupt Type Processor Register (16bit): CS Processor Register (32bit): IP Processor Register (32bit): IP Callstack (4 entries; call reverse order: first entry = last call) Callstack Callstack Callstack Callstack Callstack Callstack Callstack

Originator = 10108 MQ3CB The MQ3CB can not work properly because of the task initialization was not successful
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = designer oriented: it identifies the source module designer oriented : it identifies the line number within the source module not used not used not used not used not used not used not used not used not used not used not used not used not used

A30808-X3247-K240-3-7619

505

Outputs OML:BSC

Base Station Controller

##StartSpecProbl##
Specific Problems = 052 SYSTEM RESTART

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 410 MOSKNMSEH, 901 TOSKNMSEH, 950 UOSKNMSEH, 982 YOSKNMSEH, 992 NOSKNMSEH This error is generated when some bad actions caused a system restart.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = 0x12 not used not used not used not used not used not used not used not used not used not used not used not used not used not used SYS_RST

##StartSpecProbl##
Specific Problems = 069 AP ERROR REPORT

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 7100 TL3RDALL An Error Report message was received. Presently the error is filtered out, but if necessary its emission can be enabled by the designer.
aaaa bbbb cccc dddd eeee ffff = = = = = = Process Identifier (see annex D for more details) Process Instance Process State Not Used Process Source Line Cell

506

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = = = = = = Trx in the cell Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used

gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

Originator = 8101 TL3CIPH A 'channel activation nack' or a 'error report' with cause 'service option not implemented unspecified' has been received from BTS. This error is output by LV3 radio code.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = process number (developer oriented) absolute trx number 14h (process state) a965h (change request number) a965h (change request number) not used not used not used not used not used not used not used not used not used not used

##StartSpecProbl##
Specific Problems = 071 AP ERROR INDICATION

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 7100 TL3RDALL An Error Indication message was received


aaaa = bbbb = Process Identifier (see annex D for more details) Process Instance

A30808-X3247-K240-3-7619

507

Outputs OML:BSC
cccc = dddd = Process State Cause. It can assume the following values: 01 = Timer T200 expired (N200+1) times 02 = Re-establishment request 03 = Unsolicited UA response 04 = Unsolicited DM response 05 = Unsolicited DM response mlt. frame 06 = Unsolicited supervisory response 07 = Sequence error 08 = U frame with incorrect parameter 09 = S frame with incorrect parameter 0a = I frame with incorrect use Mbit 0b = I frame with incorrect length 0c = frame not implemented 0d = SABM command mlt. frame 0e = SABM frame with inf. not allowed Process Source Line Cell Trx in the cell Channel Subchannel Channel type Not Used Not Used Not Used Not Used Not Used

Base Station Controller

eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

= = = = = = = = = = =

##StartSpecProbl##
Specific Problems = 076 AP CONNECTION NOT ACTIVE

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 7100 TL3RDALL Reading database error: the SCCP connection indicated is not active in the system.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn = = = = = = = = = = = = = = Process Identifier (see annex D for more details) Process Instance Process State Not Used Process Source Line Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used

508

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
Not Used

oooo =

##StartSpecProbl##
Specific Problems = 078 AP CONNECTION STATUS FAULT

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 7100 TL3RDALL Updating database error : SCCP connection USAGE state mismatch.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Process Identifier (see annex D for more details) Process Instance Process State Not Used Process Source Line Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used

##StartSpecProbl##
Specific Problems = 080 AP INCONSISTENCY

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 7100 TL3RDALL General purpose error: an inconsistency between the message received (both from A and Abis interface) and the contents of the LV3 data structure occurred.
aaaa = bbbb = Process Identifier (see annex D for more details) Process Instance

A30808-X3247-K240-3-7619

509

Outputs OML:BSC
cccc dddd eeee ffff = = = =

Base Station Controller

gggg = hhhh = iiii = jjjj = kkkk = llll = mmmm = nnnn = oooo =

Process State Not Used Process Source Line if the error is detected during the validation of an SCCP message (aaaa=1c), these words report the message received, otherwise they are meaningless. if the error is detected during the validation of an SCCP message (aaaa=1c), these words report the message received, otherwise they are meaningless. if the error is detected during the validation of an SCCP message (aaaa=1c), these words report the message received, otherwise they are meaningless. if the error is detected during the validation of an SCCP message (aaaa=1c), these words report the message received, otherwise they are meaningless. if the error is detected during the validation of an SCCP message (aaaa=1c), these words report the message received, otherwise they are meaningless. if the error is detected during the validation of an SCCP message (aaaa=1c), these words report the message received, otherwise they are meaningless. if the error is detected during the validation of an SCCP message (aaaa=1c), these words report the message received, otherwise they are meaningless. if the error is detected during the validation of an SCCP message (aaaa=1c), these words report the message received, otherwise they are meaningless. if the error is detected during the validation of an SCCP message (aaaa=1c), these words report the message received, otherwise they are meaningless. if the error is detected during the validation of an SCCP message (aaaa=1c), these words report the message received, otherwise they are meaningless.

Originator = 7200 PKINRMMRMD, 7201 PKINOMMGMD, 7202 PKINGBMGBD, 7203 PKINABMABD, 7204 PKPMUTBUTC, 7205 PKPMUTBUTM, 7206 PKPMDTBDTC, 7207 PKPMDTBDTM, 7208 PKTSPRMPCH, 7209 PKTSPRMPPM, 7210 IPKTSPRMPFR, 7211 PKTSABBPDS, 7212 PKTSABBTBS, 7213 PKUTBMBUPR, 7214 PKUTBMBBVM, 7215 PKUTBMBGPG, 7216 PKUTBMBLLM, 7217 PKUTBMBLLR, 7218 PKUTBMBGOV, 7219 PKUTGEMGER, 7220 PKUTTGBTGM, 7221 PKUTTGBTBM, 7222 PKGBICOH, 7223 PKGBICSIGIH, 7224 PKGBICDATIH, 7225 PKTDPCRMIH, 7226 PKTDPCOMIH, 7227 PKTDPCOH, 7228 PKABICIH General purpose error: an inconsistency between the message managed and the contents of the UPK data structure occurred.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Process State. Process Instance. EDOS Message Code. Process Source Line. Procedure Module Originator. Procedure Module Line. Procedure Module Originator. Procedure Module Line. Procedure Module Originator. Procedure Module Line. Not used. Not used. Not used. Not used. PPCU/PPXU involved (1st byte) and Process Sending Message (2nd byte).

510

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Originator = 8209 PKTSPRMPPM PPXU/PPCU TBF Audit Task. It detects if a TBF (UL or DL) is hanged in one state without proceeding (by checking current BSN for DL TBF and VQ for UL TBF). The maximum time for releasing the TBF and consequently the related resources is 96 minutes for PPCU and 192 for PPXU.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Process State. Process Instance. EDOS Message Code. Process Source Line. UL or DL instance. BVCI. BVC trxndx. TLLI. TLLI. VQ for UL and BSN for DL. Process Source Line. Not used. Not used. Not used. PPCU/PPXU involved (1st byte) and Process Sending Message (2nd byte).

Originator = 8220 PKUTTGBTGM An inconsistency is found in RLC queue.


aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Process State. Process Instance. EDOS Message Code. Process Source Line. Procedure Module Originator. Process Source Line. Inconsistency type. RLC pool indication. Not used. Not used. Not used. Not used. Not used. Process that is now managing the RLC. PPCU/PPXU involved (1st byte) and Process Sending Message (2nd byte).

A30808-X3247-K240-3-7619

511

Outputs OML:BSC

Base Station Controller

Originator = 7999 TL3AUDIT The level 3 radio audit has released the resources associated to a call for one of the following cases: - a stable call which lasts more than 8 hours; - a not stable call which lasts more than 4 hours.
aaaa bbbb cccc dddd eeee ffff gggg = = = = = = = Absolute cell number Relative TRX number Channel number Subchannel number Channel type and timeslot Instance number of involved process Type of the released channel. It can assume the following values: 0008 = Full Rate Only 0010 = Full and Half 0020 = Main BCCH Combined or BCBCH 0040 = SDCCH or SCBCH UTF process state Absolute TRX number Connection number Absolute TRX number of a second channel involved in the dropped call Instance number of the process of a second channel involved in the dropped call Timeslot number of a second channel involved in the dropped call. Terrestrial channel State of the matrix.

hhhh iiii jjjj kkkk llll mmmm nnnn oooo

= = = = = = = =

##StartSpecProbl##
Specific Problems = 092 AP NO RADIO CHANNEL

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 7100 TL3RDALL During the sending of a DTAP message to MSC, no connection was found associated to the specified radio channel. At the moment this error is filtered out, but its emission can be enabled, if necessary, by the designer.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk = = = = = = = = = = = Process Identifier (see annex D for more details) Process Instance Process State Not Used Process Source Line Received message Received message Received message Received message Received message Received message

512

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = Received message Received message Received message Received message

llll mmmm nnnn oooo

##StartSpecProbl##
Specific Problems = 101 AP NOT UPDATED

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 7100 TL3RDALL Updating database error : has been used a wrong value of the USAGE or the ADMINISTRATIVE state of a PCMA slot.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Process Identifier (see annex D for more details) Process Instance Process State Not Used Process Source Line Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used

##StartSpecProbl##
Specific Problems = 111 AP CONFUSION

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 7100 TL3RDALL This report is generated by the Level 3 Radio when it receives a CONFUSION message
A30808-X3247-K240-3-7619 513

Outputs OML:BSC

Base Station Controller

from the MSC.


aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Cause + Error pointer Error pointer + CONFUSION message contents (ref. GSM 08.08) CONFUSION message contents (ref. GSM 08.08) CONFUSION message contents (ref. GSM 08.08) CONFUSION message contents (ref. GSM 08.08) CONFUSION message contents (ref. GSM 08.08) CONFUSION message contents (ref. GSM 08.08) CONFUSION message contents (ref. GSM 08.08) CONFUSION message contents (ref. GSM 08.08) CONFUSION message contents (ref. GSM 08.08) CONFUSION message contents (ref. GSM 08.08) CONFUSION message contents (ref. GSM 08.08) CONFUSION message contents (ref. GSM 08.08) CONFUSION message contents (ref. GSM 08.08) CONFUSION message contents (ref. GSM 08.08)

##StartSpecProbl##
Specific Problems = 115 MEMT SEMAPHORE LOCKED

Event Type = EQUIPMENT FAILURE EVENT Severity = MAJOR Proposed Repair Actions = 1 NO ACTION

Originator = 308 MOSICIOIT The semaphores of TDPC DUAM are blocked: the MPCC input task (TASK_I_O) cannot read the DUAM.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = not used not used not used not used not used not used not used not used not used not used not used not used not used not used not used

514

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Originator = 309 MOSICIOOT The semaphores of TDPC DUAM are blocked: the MPCC output task (TASK_I_O) cannot write the DUAM.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = not used not used not used not used not used not used not used not used not used not used not used not used not used not used not used

Originator = 812 TOSICIOIT The DUAM semaphores of the TDPC are blocked: the TDPC input task (TASK_I_O) cannot read the DUAM.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = not used not used not used not used not used not used not used not used not used not used not used not used not used not used not used

Originator = 813 TOSICIOOT The DUAM semaphores of the TDPC are blocked: the TDPC output task (TASK I O)
A30808-X3247-K240-3-7619 515

Outputs OML:BSC

Base Station Controller

cannot write the DUAM.


aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = not used not used not used not used not used not used not used not used not used not used not used not used not used not used not used

##StartSpecProbl##
Specific Problems = 131 CTR GENERIC MESSAGE

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 5002 CPM_CTR_ORIGINATOR This message is issued by CTR Tracing task if there are problems before a request of tracing or if there are informations about the tracement itself All related additional info are developer oriented and useful for debugging activity
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Module that generates the error. Source code line of the module that generates the error. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use. Internal use.

516

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

##StartSpecProbl##
Specific Problems = 136 INVALID MESSAGE TO PSOS

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 309 MOSICIOOT It is not possible to have a pSOS+ buffer with the specified length.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = 0x24 INVALID_MESSAGE_POINTER. Current value of the variable source_sys. Current value of the variable dest_sys. Current value of the variable source_mbx. Current value of the variable dest_mbx. Current value of the variable signal_type. Current value of the variable signal_subtype. Current value of the variable datalen. Current value of the variable err. Not used. Not used. Not used. Not used. Not used. Not used.

##StartSpecProbl##
Specific Problems = 137 INVALID SEND MESSAGE IN RTE

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 309 MOSICIOOT It is not possible to send a pSOS message.


aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii = = = = = = = = = 0x26 INVALID_RTE_OUTPUT. Current value of the variable source_sys. Current value of the variable dest_sys. Current value of the variable source_mbx. Current value of the variable dest_mbx. Current value of the variable signal_type. Current value of the variable signal_subtype. Current value of the variable datalen. Current value of the variable err.

A30808-X3247-K240-3-7619

517

Outputs OML:BSC
jjjj kkkk llll mmmm nnnn oooo = = = = = = Not used. Not used. Not used. Not used. Not used. Not used.

Base Station Controller

##StartSpecProbl##
Specific Problems = 138 INVALID RECEIVE MESSAGE IN RTE

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 308 MOSICIOIT It is not possible to receive a pSOS message correctly.


aaaa = bbbb = cccc = dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = 0x23 INVALID_RTE_INPUT. Current value of the variable err. Current value of the variable mbx_id, identifier of the mailbox on which we are waiting for the message. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

##StartSpecProbl##
Specific Problems = 148 PSE ERROR

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 310 MOSICIOIO

518

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

It is not possible to open the specified stream.


aaaa = bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = 0x01 INVALID_STREAM_OPEN. 0x02 INVALID_STREAM_IOCTL. Current return value of the stream system call. Current value of the board number. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

Originator = 311 MOSICIOPO


It is not possible to allocate an mblk aaaa = 0x03 INVALID_MBLK_ALLOCATION. bbbb = Current value of the mblk length. cccc = Current value of the board number. dddd = Not used. eeee = Not used. ffff = Not used. gggg = Not used. hhhh = Not used. iiii = Not used. jjjj = Not used. kkkk = Not used. llll = Not used. mmmm = Not used. nnnn = Not used. oooo = Not used.

##StartSpecProbl##
Specific Problems = 149 INVALID SEND MESSAGE

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 311 MOSICIOPO

A30808-X3247-K240-3-7619

519

Outputs OML:BSC

Base Station Controller

The destination system of the message received is wrong.


aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = 0x06 INVALID_DEST_SYS. Current value of the dest_sys of the pSOS message. Current value of the board number. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

Originator = 312 MOSICIOPI It is not possible to send a message.


aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = 0x05 INVALID_PSOS_INPUT. Current value of the source_sys. Current value of the dest_sys. Current value of the source_mbx. Current value of the dest_mbx. Current value of the signal_type. Current value of the signal_subtype. Current value of the message length. System call return value. Current value of the board number. Not used. Not used. Not used. Not used. Not used.

##StartSpecProbl##
Specific Problems = 150 INVALID STREAM OUTPUT

Event Type = PROCESSING FAILURE EVENT Severity = MINOR Proposed Repair Actions = 1 NO ACTION

520

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Originator = 311 MOSICIOPO


It is not possible to write the message into the IPC stream. aaaa = 0x07 INVALID_PUTMSG. bbbb = Current value of the stream identifier. cccc = Current value of the returned err. dddd = Current value of the board number. eeee = Not used. ffff = Not used. gggg = Not used. hhhh = Not used. iiii = Not used. jjjj = Not used. kkkk = Not used. llll = Not used. mmmm = Not used. nnnn = Not used. oooo = Not used.

##StartSpecProbl##
Specific Problems = 154 INVALID CLOSE

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 308 MOSICIOIT, 310 MOSICIOIO


It is not possible to close the IPC stream. aaaa = 0x09 INVALID_PSOS_CLOSE. bbbb = Current value of the returned err. cccc = Current value of the board number. dddd = Not used. eeee = Not used. ffff = Not used. gggg = Not used. hhhh = Not used. iiii = Not used. jjjj = Not used. kkkk = Not used. llll = Not used. mmmm = Not used. nnnn = Not used. oooo = Not used.

##StartSpecProbl##
Specific Problems = 178 TRAU ALIGNMENT FAILED

Event Type = COMMUNICATION FAILURE EVENT


A30808-X3247-K240-3-7619 521

Outputs OML:BSC

Base Station Controller

Severity = CRITICAL Proposed Repair Actions = 26 CHECK THE TRAU

Originator = 4752 TDHTRDCMC This error occurs when the device handler of the TRAUs fails the alignment procedure towards the Network Element.
aaaa = Internal code of the event that triggered this failed alignment: TRAU_TMOUT = 01, timeout occurred TRAU_SMENBL = 02, status manager ENABLE command TRAU_SMDSBL = 03, status manager DISABLE command TRAU_SMLOCK = 04, status manager LOCK command TRAU_SMUNLOCK = 05, status manager UNLOCK command TRAU_SWALGOK = 06, successful end of SW alignment TRAU_SWALGFAIL = 07, failed SW alignment TRAU_SWREFRESH = 08, refresh from SW alignment process TRAU_SWSTRDWLD = 09, started download of NE TRAU_SWALGEND = 0a, successful end of download TRAU_SWACTREQ = 0b, software activation TRAU_LINKUP = 0c, link transition down->up TRAU_LINKDOWN = 0d, link transition up->down TRAU_RCVNACK = 0e, received nack reply during alignment TRAU_MSGDSBL = 0f, notification of TRAU disabled TRAU_MSGENBL = 10, notification of TRAU enabled TRAU_STOPEVREP = 11, ack to "Stop sending event report" TRAU_RSTEVREP = 12, ack to "Restart sending event report" TRAU_RESETRES = 13, ack to "Reset resource message" TRAU_FAILEDPROC = 14, failed elementary procedure TRAU_AUDITFAIL = 15, audit of state is not consistent TRAU_ALGNREQ = 16, alignment request from system TRAU_DBDHKLV = 17, periodical execution audit TRAU_DBDHERR = 18, failed dbdh procedure TRAU_DBDHREQ = 19, request queued to dbdh TRAU_DBDHRPL = 1a, reply received from dbdh TRAU_ADMOK = 1b, ackwnoledge of an administrative state proc Internal code of the current state of main state machine: TRFS_LNKDW = 00, TRFS_ALGN = 01, TRFS_RELAX = 02, TRFS_MON = 03 Internal code of the current state of alignment state machine: WAIT_STOP_EVT_ACK = 00, WAIT_SW_ALIGN_RES = 01, WAIT_DB_ALIGN_RES = 02, WAIT_RST_EVT_ACK = 03, WAIT_RST_RES_ACK = 04, WAIT_EVENT_FLOW = 05, WAIT_LINK_DOWN = 06 Internal code of the event that determined last alignment: TRAU_TMOUT = 01, timeout occurred TRAU_SMENBL = 02, status manager ENABLE command TRAU_SMDSBL = 03, status manager DISABLE command TRAU_SMLOCK = 04, status manager LOCK command TRAU_SMUNLOCK = 05, status manager UNLOCK command TRAU_SWALGOK = 06, successful end of SW alignment TRAU_SWALGFAIL = 07, failed SW alignment TRAU_SWREFRESH = 08, refresh from SW alignment process TRAU_SWSTRDWLD = 09, started download of NE TRAU_SWALGEND = 0a, successful end of download TRAU_SWACTREQ = 0b, software activation TRAU_LINKUP = 0c, link transition down->up TRAU_LINKDOWN = 0d, link transition up->down TRAU_RCVNACK = 0e, received nack reply during alignment TRAU_MSGDSBL = 0f, notification of TRAU disabled

bbbb =

cccc =

dddd =

522

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
TRAU_MSGENBL = 10, notification of TRAU enabled TRAU_STOPEVREP = 11, ack to "Stop sending event report" TRAU_RSTEVREP = 12, ack to "Restart sending event report" TRAU_RESETRES = 13, ack to "Reset resource message" TRAU_FAILEDPROC = 14, failed elementary procedure TRAU_AUDITFAIL = 15, audit of state is not consistent TRAU_ALGNREQ = 16, alignment request from system TRAU_DBDHKLV = 17, periodical execution audit TRAU_DBDHERR = 18, failed dbdh procedure TRAU_DBDHREQ = 19, request queued to dbdh TRAU_DBDHRPL = 1a, reply received from dbdh TRAU_ADMOK = 1b, ackwnoledge of an administrative state proc not used not used not used not used not used not used not used not used not used not used not used

eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

= = = = = = = = = = =

##StartSpecProbl##
Specific Problems = 179 BTSM FAILED ALIGNMENT

Event Type = COMMUNICATION FAILURE EVENT Severity = CRITICAL Proposed Repair Actions = 1 NO ACTION

Originator = 4704 TDHBFDCMC This error occurs when the link goes down or a nack message is received during a BTSM alignment procedure.
aaaa = Incoming event the BTSM DH is handling: (DHBFI.H) ==> BMEVT_NONE = 0x00, BMEVT_TMOUT = 0x01, BMEVT_SWALGOK = 0x02, BMEVT_SWALGEND = 0x03, BMEVT_SWSTRDWLD = 0x04, BMEVT_SWALGFAIL = 0x05, BMEVT_SWREFRESH = 0x06, BMEVT_LINKUP = 0x07, BMEVT_LINKDOWN = 0x08, BMEVT_ABISTMT = 0x09, BMEVT_ABISENDERR = 0x0a, BMEVT_SYSALGNREQ = 0x0b, BMEVT_AUDITFAIL = 0x0c, BMEVT_MSGDSBL = 0x0d, BMEVT_MSGENBL = 0x0e, BMEVT_STOPEVREP = 0x0f, BMEVT_RSTEVREP = 0x10, BMEVT_RESETRES = 0x11,

A30808-X3247-K240-3-7619

523

Outputs OML:BSC
BMEVT_RCVNACK = 0x12, BMEVT_SMENBL = 0x13, BMEVT_SMDSBL = 0x14, BMEVT_SMUNLOCK = 0x15, BMEVT_DBDHKLV = 0x16, BMEVT_DBDHERR = 0x17, BMEVT_DBDHREQ = 0x18, BMEVT_DBDHRPL = 0x19, BMEVT_ADMOK = 0x1a, BMEVT_BFSTRTM = 0x1b, BMEVT_ABISDEL = 0x1c BMEVT_SALESOK, = 0x1d BMEVT_SALESFAIL = 0x1e BMEVT_SMLOCK = 0x1f BMEVT_LOCKOK = 0x20 Current state of the BTSM finite state machine BMFSM_LINK_DOWN = 0x00, BMFSM_WAIT_STOP_EVT = 0x01, BMFSM_WAIT_SW_ALIGN = 0x02, BMFSM_WAIT_DB_ALIGN = 0x03, BMFSM_WAIT_RESET_RES = 0x04, BMFSM_WAIT_REST_EVT = 0x05, BMFSM_WAIT_EVT_REP = 0x06, BMFSM_MONITOR = 0x07, BMFSM_WAIT_DBDH = 0x08, BMFSM_WAIT_RELAX_TIME= 0x09 BMFSM_WAIT_SALES_EVT = 0x0a BMFSM_WAIT_LOCK = 0x0b New state of the BTSM finite state machine see above. not used not used not used not used not used not used not used not used not used not used not used not used

Base Station Controller

bbbb =

cccc = dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = =

##StartSpecProbl##
Specific Problems = 220 BAD SOFTWARE ON PERIPHERAL CARD

Event Type = PROCESSING FAILURE EVENT Severity = MINOR Proposed Repair Actions = 1 NO ACTION

Originator = 45 MDHXXLUEH

524

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

This error is issued in four cases: a) PPXL/PPXU patch load fails because of File System problems (CSD_FS_FAILED Load Server answer); the card is not Offline. b) PPXL/PPXU patch load fails because a PPXL/PPXU card (not Offline) is waiting for Load Server ack (before Load) or Load Server result, but a time-out takes place or a negative answer (CSD_FAILED) comes from Load Server during a second retry of Load (Recovery). c) PPxx SW load fails for timeout or Load Server problems (finite state is Waiting For Load). d) PPxx SW load fails for file system problems (no BSC Agent command is in progress). e) PPxx SW load fails (finite state is Load Running) because of Load Server time-out or card HW/SW problem (no BSC Agent command is in progress).
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Line Status on local database Successfull / Unsuccesfull command for involved card Current command in progress Patch Type (permanet / no permanent ) me_mnemonic me_address Hig byte of cardMask in actual vdhxx_luBscAgCmd structure Low byte of cardMask in actual vdhxx_luBscAgCmd structure Hig byte of activeMask in actual vdhxx_luBscAgCmd structure Low byte of activeMask in actual vdhxx_luBscAgCmdCmd structure Field CMD in actual vdhxx_luBscAgCmd structure me_addres of rsuExeId field in actual vdhxx_luBscAgCmd structure me_mnemonic of rsuExeId field in actual vdhxx_luBscAgCmd structure Originator

Originator = 4502 MDHXXDCEH This error is issued in four cases: a) PPCU patch load fails because of File System problems (CSD_FS_FAILED Load Server answer); the card is not Offline. b) PPCU patch load fails because a PPCU card (not Offline) is waiting for Load Server ack (before Load) or Load Server result, but a time-out takes place or a negative answer (CSD_FAILED) comes from Load Server during a second retry of Load (Recovery). c) PPxx SW load fails for timeout or Load Server problems (finite state is Waiting For Load). d) PPxx SW load fails for file system problems (no BSC Agent command is in progress). e) PPxx SW load fails (finite state is Load Running) because of Load Server time-out or card HW/SW problem (no BSC Agent command is in progress).
aaaa = a) Source code line b) Source code line c) Source code line d) Source code line e) Source code line a) status (bit mask of Status Manager statuses, reassigned according to the following values: 0x01 = XX_DEPENDENCY 0x02 = XX_FAILED 0x04 = XX_INITIALIZING 0x08 = XX_IN_TEST 0x10 = XX_NOT_INITIALIZED 0x20 = XX_OFFLINE

bbbb =

A30808-X3247-K240-3-7619

525

Outputs OML:BSC

Base Station Controller

cccc =

dddd =

eeee =

ffff =

gggg =

hhhh =

iiii =

jjjj =

kkkk =

llll =

mmmm =

nnnn =

oooo =

0x40 = XX_RSVD_FOR_TEST 0x80 = XX_NOT_INIT_ALARMED b) Event (4 = time-out, 10 = Load Server nack, 17 = Load Server fault) c) Event (4 = time-out, 17 = Load Server Fault, 18 = Load Server Card fault) d) Event (SW Load File System failure) e) Event (4 = time-out, 17 = Load Server Fault, 18 = Load Server Card fault) a) Command result (for answer to BSC Agent) b) Card finite state c) Card finite state d) Status (bit mask) e) Initial finite state a) Number of current command b) Not used c) Not used d) Current command e) Not used a) patch type (0 = All Permanent, 1 = All Running, 2 = Single Patch) in Patch Load command b) Not used c) Not used d) Not used e) Not used a) Me mnemonic of id associated to patch load b) Not used c) Not used d) Not used e) Not used a) Me_address[0] of id associated to patch load. b) Not used c) Not used d) Not used e) Not used a) Low word in cards mask associated to BSC Agent command b) Not used c) Not used d) Not used e) Not used a) High word in cards mask associated to BSC Agent command b) Not used c) Not used d) Not used e) Not used a) Low word in mask of cards whose command must be processed b) Not used c) Not used d) Not used e) Not used a) High word in mask of cards whose command must be processed b) Not used c) Not used d) Not used e) Not used a) Command (0xFF if no command) b) Not used c) Not used d) Not used e) Not used a) Id inside BSC Agent command (me address[0]). b) Not used c) Not used d) Not used e) Not used a) Id inside BSC Agent command (me mnemonic) b) Not used c) Not used d) Not used e) Not used a) Command originator (1 = PPXX DIAGNOSTIC TEST; 2 = BSC AGENT COMMAND)

526

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
b) Not used c) Not used d) Not used e) Not used

Originator = 4505 MDHXXDCTH 4516 MDHXXLUTH This error is issued in two cases: a) During patch load due to PPCU/PPXU DH recovery, if a SDBA utility (fsdba_GetLoadingInfo) fails. b) During SW load due to PPCU/PPLD/PPCC/PPXU?PPXL DH recovery, if a SDBA utility (fsdba_GetLoadingInfo) fails.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = a) e b) Source code line a) e b) status a) e b) Not used a) e b) Not used a) e b) Not used a) e b) Not used a) e b) Not used a) e b) Not used a) e b) Not used a) e b) Not used a) e b) Not used a) e b) Not used a) e b) Not used a) e b) Not used a) e b) Not used

Originator = 4500 MDHXXDCCH 4511 MDHXXLUCH This error is issued in two cases: During PPxx SW version check (load due to PPCU/PPXU DH recovery), if a SDBA utility (fsdba_GetLoadingInfo) fails.
aaaa bbbb cccc dddd eeee ffff gggg hhhh = = = = = = = = Source code line Staus Not Used Not Used Not Used Not Used Not Used Not Used

A30808-X3247-K240-3-7619

527

Outputs OML:BSC
iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = Not Used Not Used Not Used Not Used Not Used Not Used Not Used

Base Station Controller

Originator = 4508 MDHXXGSUT 4518 MDHXXLUUT During PPxx SW version check (for load), if a SDBA utility (fsdsmGetExeSvr) fails.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Source code line status Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used

##StartSpecProbl##
Specific Problems = 222 AP TRACE ERROR NOTIFICATION

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 7100 TL3RDALL An error is occurred while managing a Trace procedure.


aaaa bbbb cccc dddd eeee ffff = = = = = = Process Identifier (see annex D for more details) Process Instance Process State Not Used Process Source Line Trace Error Cause

528

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = = = = = = Trace Reference Mobile Identity (see GSM 04.08) Mobile Identity (see GSM 04.08) Mobile Identity (see GSM 04.08) Mobile Identity (see GSM 04.08) Mobile Identity (see GSM 04.08) Not Used Not Used Not Used

gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

##StartSpecProbl##
Specific Problems = 229 BRING UP ACTIVE REQUESTED

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 507 MSDBASDL A new bring up initialization is requested due to a serious software fault.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to rebuild MPCC processor call stack. Used by the designer to rebuild MPCC processor call stack. Used by the designer to rebuild MPCC processor call stack. Used by the designer to rebuild MPCC processor call stack. Used by the designer to rebuild MPCC processor call stack. Used by the designer to rebuild MPCC processor call stack. Used by the designer to rebuild MPCC processor call stack. Used by the designer to rebuild MPCC processor call stack. Used by the designer to rebuild MPCC processor call stack. Used by the designer to rebuild MPCC processor call stack. Used by the designer to rebuild MPCC processor call stack. Used by the designer to rebuild MPCC processor call stack. Used by the designer to rebuild MPCC processor call stack. Used by the designer to rebuild MPCC processor call stack. Used by the designer to rebuild MPCC processor call stack.

##StartSpecProbl##
Specific Problems = 240 REPORT INCOMPLETED

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

A30808-X3247-K240-3-7619

529

Outputs OML:BSC

Base Station Controller

Originator = 3204 MSMGSHRIH This error is output in 3 cases: a) TRAU or BTSE not accessible b) exchange message problem with DHLP subsystem c) exchange message problem with DHGP subsystem
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Source code line (a); object mnemonic (b), (c) object mnemonic (a); madd[0] (b), (c) madd[0] (a); madd[1] (b), (c) madd[1] (a); madd[2] (b), (c) madd[2] (a); madd[3] (b), (c) madd[3] (a); madd[4] (b), (c) neNbr (a); madd[4] (b), (c) objClass (a) objInst[0] (a) objInst[1] (a) objInst[2] (a) type: CSM_ABIS or CSM_ASUB (a) CSMGS_NE_NOT_AVAIL (a) Not used Not used

Originator = 4351 MDHBCDCDE This error is output in two cases: - when the Get Info manager doesnt receive any answer from the Device Handler; - when a generic Nack Cause is received by the Device Handler. The get info report is issued and this error signals that the information output are incompleted.
aaaa = bbbb = cccc = dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = Source code line (designer oriented). internal get info command indentifier OR getinfo object (designer oriented). current level, this is a field of the local database OR index of the "state machine" processed (designer oriented). low map, this is a field of the local database OR action to be executed (designer oriented). high map, this is a field of the local database OR result of the processing (designer oriented). destination of the report, this is a field of the local database OR not used (designer oriented). Not used Not used Not used Not used Not used Not used Not used Not used Not used

530

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Originator = 45xx MDHXXLUDE This warning message is issued when a PPXU / PPXL Get Info command generates an incomplete
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Line Item code number of card involved NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED

Originator = 4501 MDHXXDCDE This warning message is issued when a PPCU Get Info command generates an incomplete report, because of one of the following conditions: a) HW problem or time-out during interface with PPCU Agent (on PCUC) for acquisition of card information (Pentium counters) b) Uncorrect answer from PCUC (see point a) c) HW problem or time-out during Give Status command (MPCC - PCUC) d) Missing answer from GbIC processor (interface for counters concerning real time) e) Uncorrect answer from GbIC (erroneous PCU number or GbIC Get Counters Nack)
aaaa = bbbb = source code line (all cases) item identifier (high byte, with the meaningful of: 1 = DHXXDCCH.C, 2 = DHXXDCDE, 3 = DHXXDCEH, 4 = DHXXDCSA, 5 = DHXXDCSM, 6 = DHXXDCTH, 7 = DHXXDDDI, 8 = DHXXDDHD, 9 = DHXXGSUT, 10 = DHXXINIT, 11 = DHXXDGHD, 12 = DHXXDDPU) and error code (low byte; possible values: 0x8a = time-out in MPCC-PCUC command interface, 0xe3 = loopback test failure, 0xe4 = NMI during access to card, 0x8f = HW semaphore locked, 0xa0 = alarm detection while sending command, 0xa3 = wrong writing operation while sending command, 0x8c = missing PCUC SW/FW acknowledge on DUAM, 0x1b = timeout expired in GbIC - MPCC interface, 0x1a = GbIC Nack or unexpected response) (all cases) PPCU number (all cases) value of SW semafore inside MPCC -> PCUC interface (all cases) first byte inside MPCC -> PCUC command (on DUAM) (all cases) second byte inside MPCC -> PCUC command (all cases) value of SW semafore inside PCUC -> MPCC interface (all cases) first byte inside PCUC -> MPCC answer (on DUAM) (all cases) second byte inside PCUC -> MPCC answer (all cases)

cccc dddd eeee ffff gggg hhhh iiii

= = = = = = =

A30808-X3247-K240-3-7619

531

Outputs OML:BSC
jjjj = kkkk = llll = mmmm = nnnn = oooo =

Base Station Controller

third byte inside PCUC -> MPCC answer (all cases) fourth byte inside PCUC -> MPCC answer (all cases) copy of last written byte on UBEX register of PPCU (low byte) and alarms mask directly read on it (high byte) (all cases) first byte of PCUC answer (cases d, e only) second byte of PCUC answer (cases d, e only) third byte of PCUC answer (cases d, e only)

Originator = 4951 TDHGPDCDE This error is output in two cases: - when the DH doesnt receive any answer from the card's processors; - when the request from MDHBC concerns a PCU not in MONITOR
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Source code line (designer oriented). PCU number Target Object class Target Object Instance cmd code Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used

##StartSpecProbl##
Specific Problems = 248 PPXX DEVICE HANDLER INTER PROCESSOR COMMUNICATION SEMAPHORE LOCKED

Event Type = PROCESSING FAILURE EVENT Severity = MINOR Proposed Repair Actions = 1 NO ACTION

Originator = 4506 MDHXXDDDI This error message is issued when PPLD (PPCC) Device Handler interface with IPC fails during a writing or reading operation on MEMT (PPxx data), because a semaphore keeps its high state even if a reset done by PPxx DH.
aaaa = bbbb = Source file internal identifier (DHXXDDDI) Source line.

532

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = = = = = = = = = = Error code (DUAM Semaphore Locked) Type of action on MEMT (1 = Read DUAM, 2 = Write DUAM) Number of attempts done in order to free semaphore. Number of physical PPLD or PPCC card. Not used Not used Not used Not used Not used Not used Not used Not used Not used

cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

##StartSpecProbl##
Specific Problems = 250 IMSI TRACE GENERIC MESSAGE

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 5001 CPM_IMSI_ORIGINATOR This message is issued if there are problems before a request of tracing or if there are informations about the tracement itself. All related additional info are developer oriented and useful for debugging activity
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Module that generates the error. Source code line of the module that generates the error. Internal use Internal use Internal use Internal use Internal use Internal use Internal use Internal use Internal use Internal use Internal use Internal use Internal use

##StartSpecProbl##
A30808-X3247-K240-3-7619 533

Outputs OML:BSC
Specific Problems = 255 FULL INITIALIZATION OCCURRED

Base Station Controller

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 507 MSDBASDL This alarm is output when a system full initialization spontaneously occurred caused by BSC software problems. This alarm is of particular interest for the OMC; in case the link is temporary down, the BSC Agent software stores it internally untill the link returns up.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = =

Originator = 607 MSDBAFPBU This alarm is output when a system full initialization spontaneously occurred when a first OMC connection is performed. This alarm is of particular interest for the OMC; in case the link is temporary down, the BSC Agent software stores it internally untill the link returns up.This is not a Init user request notification.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to rebuild the MPCC processor call stack. Used by the designer to rebuild the MPCC processor call stack. Used by the designer to rebuild the MPCC processor call stack. Used by the designer to rebuild the MPCC processor call stack. Used by the designer to rebuild the MPCC processor call stack. Used by the designer to rebuild the MPCC processor call stack. Used by the designer to rebuild the MPCC processor call stack. Used by the designer to rebuild the MPCC processor call stack. Used by the designer to rebuild the MPCC processor call stack. Used by the designer to rebuild the MPCC processor call stack. Used by the designer to rebuild the MPCC processor call stack. Used by the designer to rebuild the MPCC processor call stack. Used by the designer to rebuild the MPCC processor call stack. Used by the designer to rebuild the MPCC processor call stack. Used by the designer to rebuild the MPCC processor call stack.

534

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

##StartSpecProbl##
Specific Problems = 256 BRING UP INITIALIZATION OCCURRED

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 507 MSDBASDL This alarm is output when a system Bring Up initialization spontaneously occurred caused by BSC software problems. This alarm is of particular interest for the OMC; in case the link is temporary down, the BSC Agent software stores it internally untill the link returns up.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to rebuild the MPCC processor call stack. Used by the designer to rebuild the MPCC processor call stack. Used by the designer to rebuild the MPCC processor call stack. Used by the designer to rebuild the MPCC processor call stack. Used by the designer to rebuild the MPCC processor call stack. Used by the designer to rebuild the MPCC processor call stack. Used by the designer to rebuild the MPCC processor call stack. Used by the designer to rebuild the MPCC processor call stack. Used by the designer to rebuild the MPCC processor call stack. Used by the designer to rebuild the MPCC processor call stack. Used by the designer to rebuild the MPCC processor call stack. Used by the designer to rebuild the MPCC processor call stack. Used by the designer to rebuild the MPCC processor call stack. Used by the designer to rebuild the MPCC processor call stack. Used by the designer to rebuild the MPCC processor call stack.

##StartSpecProbl##
Specific Problems = 274 PCU ALIGNMENT FAILURE

Event Type = PROCESSING FAILURE EVENT Severity = CRITICAL Proposed Repair Actions = 1 NO ACTION

Originator = 4952 TDHGPDCMC This error occurs when the PCUalignment is interrupted.
A30808-X3247-K240-3-7619 535

Outputs OML:BSC
aaaa = bbbb = the line number of the source module PCU FSM state: 00 - GPFSM_OOS 01 - GPFSM_WAIT_CARD_ON 02 - GPFSM_INITIALIZING 03 - GPFSM_RELAX 04 - GPFSM_MONITOR Event causing the alignment interruption: 00 - GPEVT_NONE 01 - GPEVT_TMOUT 02 - GPEVT_CARDON 03 - GPEVT_CARDOFF 04 - GPEVT_PCUTMT 05 - GPEVT_PCUSENDERR 06 - GPEVT_PCUALGNREQ 07 - GPEVT_AUDITFAIL 08 - GPEVT_CMDFAIL 09 - GPEVT_CMDRESP 0a - GPEVT_CMDEND 0b - GPEVT_ALGNSTART 0c - GPEVT_SMUNLOCK 0d - GPEVT_SMLOCK 0e - GPEVT_SMDISABLE 0f - GPEVT_SMENABLE PCU Alignment state: 00 - GPASM_WAIT_START_ALGN 01 - GPASM_WAIT_PCU_ALGN 02 - GPASM_WAIT_PTP_ALGN 03 - GPASM_WAIT_GBICU_ALGN 04 - GPASM_WAIT_FRL_ALGN 05 - GPASM_WAIT_NSVC_ALGN 06 GPASM_WAIT_SCAN_ALGN Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used

Base Station Controller

cccc =

dddd =

eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

= = = = = = = = = = =

##StartSpecProbl##
Specific Problems = 303 NOTIFIED GBIC CONFIGURATION MISMATCH

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 4953 TDHGPIHGB This error maps a GbIC error event on BSC alarm in the following cases: an O&M command for an object not yet created has been received
536 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

(OM_EVT_OBJ_NOT_CREATED), an O&M Create Object command for an object already created has been received(OM_EVT_ OBJ_ALREADY_CREATED), An invalid response has been received from Physical Bearer Handler (OM_ INVALID_PH_RESP), Error response reported from Physical Bearer Handler (OM_ PH_ERR), An NSVC could not be bound to a FRL (OM_ FRL_ATTACH_FAIL).
aaaa = GbIC ERROR CAUSE: 0x10 = OM_EVT_OBJ_NOT_CREATED 0x11 = OM_EVT_ OBJ_ALREADY_CREATED 0x20 = OM_ INVALID_PH_RESP 0x21 = OM_ PH_ERR 0x22 = OM_ FRL_ATTACH_FAIL case ERROR CAUSE: - OM_EVT_OBJ_NOT_CREATED: - OM_EVT_ OBJ_ALREADY_CREATED: command type - OM_ INVALID_PH_RESP: response type - OM_ PH_ERR: command issued to Physical Bearer Handler - OM_ FRL_ATTACH_FAIL: failure cause (1 FRL not available, 2 DLCI already present, 3 DLCI reserved for PVC Handler signalling) case ERROR CAUSE: - OM_EVT_OBJ_NOT_CREATED: - OM_EVT_ OBJ_ALREADY_CREATED: message sequence number - OM_ INVALID_PH_RESP: relevant invalid parameter - OM_ PH_ERR: command issued to Physical Bearer Handler - OM_ FRL_ATTACH_FAIL: failure cause (1 FRL not available, 2 DLCI already present, 3 DLCI reserved for PVC Handler signalling) case ERROR CAUSE: - OM_ PH_ERR: PH error code - OM_ FRL_ATTACH_FAIL: FRL index case ERROR CAUSE: - OM_ PH_ERR: PH error code - OM_ FRL_ATTACH_FAIL: protocol state of the NSVC case ERROR CAUSE: - OM_ PH_ERR: protocol state of the relevant GbIC object Not used Not used Not used Not used Not used Not used Not used Not used Not used

bbbb =

cccc =

dddd =

eeee =

ffff = gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = =

##StartSpecProbl##
Specific Problems = 309 AP NOFREE PDT

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 7100 TL3RDALL All available PDT in the PCU are BUSY or DISABLE.
aaaa = Process Identifier (see annex D for more details)

A30808-X3247-K240-3-7619

537

Outputs OML:BSC
bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = Process Instance Process State Not used Process Source Line PCU number Not used Not used Not used Not used Not used Not used Not used Not used Not used

Base Station Controller

##StartSpecProbl##
Specific Problems = 310 NOTIFY GPRS PREHEMPTION

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 8102 TL3GPRS GPRS Preemption has been enabled or disabled.


aaaa = bbbb = cccc = dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = GPRS Preemption new status: if 1 GPRS Preemption is enabled, if 0 GPRS Preemption is disabled Cell index Mask indicating the packet data channels allocated on the BCCH TRX for the specified cell (present only if additional info aaaa is equal to 0) Preemption mask from PCU (present only if additional info aaaa is equal to 0) Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used

538

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

##StartSpecProbl##
Specific Problems = 314 DELETED CURRENT TASK LOWINIT

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 410 MOSKNMSEH, 901 TOSKNMSEH, 950 UOSKNMSEH, 982 YOSKNMSEH, 992 NOSKNMSEH A task or a scan work function caused an exception and the system deletes it; if the Entry point is equal to zero the activity which caused the interrupt is a scan work function.A RTE System Info Report is related to this message. For more details, please refers to ANNEX E. A TASK PRIME initialization is required because the number of deleted task/swf has reached the lower threshold.
aaaa = 0x14 DEL CURR TSK 0x1E DEL CURR SWF 0x2D DEL CURR TSK PSOS Task Entry Point (offset 32bit) Task Entry Point (offset 32bit) Interrupt Type Processor Register (16bit): CS Processor Register (32bit): IP Processor Register (32bit): IP Callstack (4 entries; call reverse order: first entry = last call) Callstack Callstack Callstack Callstack Callstack Callstack Callstack

bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

= = = = = = = = = = = = = =

##StartSpecProbl##
Specific Problems = 315 DELETED CURRENT TASK UPPINIT

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 410 MOSKNMSEH, 901 TOSKNMSEH, 950 UOSKNMSEH, 982 YOSKNMSEH, 992 NOSKNMSEH A task or a scan work function caused an exception and the system deletes it; if the Entry point is equal to zero the activity which caused the interrupt is a scan work function.A RTE System Info Report is related to this message. For more details, please refers to ANNEX E. A FULL initialization is required because the number of deleted task/swf has reached the upper threshold.
A30808-X3247-K240-3-7619 539

Outputs OML:BSC
aaaa = 0x14 DEL CURR TSK 0x1E DEL CURR SWF 0x2D DEL CURR TSK PSOS Task Entry Point (offset 32bit) Task Entry Point (offset 32bit) Interrupt Type Processor Register (16bit): CS Processor Register (32bit): IP Processor Register (32bit): IP Callstack (4 entries; call reverse order: first entry = last call) Callstack Callstack Callstack Callstack Callstack Callstack Callstack

Base Station Controller

bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

= = = = = = = = = = = = = =

##StartSpecProbl##
Specific Problems = 322 SDSM SM DATABASE NOT ALIGNED

Event Type = PROCESSING_FAILURE_EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 506 MSDSM The database of sdsm and the database of sm are not aligned because sm do not sends an acknowledgemnt to sdsm after a create/delete object request
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used

540

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

##StartSpecProbl##
Specific Problems = 323 SDSM DATABASE NOT ALIGNED

Event Type = PROCESSING_FAILURE_EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 506 MSDSM because of the failure of an operation on rsu objects, for example the object is not valid or it's busy in another operation, the database of sdsm is no more aligned
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used

##StartSpecProbl##
Specific Problems = 324 ANOTHER OPERATION IS IN PROGRESS

Event Type = PROCESSING_FAILURE_EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 506 MSDSM It is'nt possible to make the operation required on the object because the object is busy by another operation
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj = = = = = = = = = = Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used

A30808-X3247-K240-3-7619

541

Outputs OML:BSC
kkkk llll mmmm nnnn oooo = = = = = Not used Not used Not used Not used Not used

Base Station Controller

##StartSpecProbl##
Specific Problems = 326 DOWNLOAD FAILED

Event Type = PROCESSING_FAILURE_EVENT Severity = MINOR Proposed Repair Actions = 5 SEE THE PROPOSED ACTION IN THE MANUAL

Originator = 506 MSDSM the download procedure is not terminated because the meid of the object is not valid and it isn't possible to obtain by the meid the subtype value of integer type
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used

##StartSpecProbl##
Specific Problems = 327 FILE UNUSABLE

Event Type = PROCESSING FAILURE EVENT Severity = MINOR Proposed Repair Actions = 5 SEE THE PROPOSED ACTION IN THE MANUAL

Originator = 506 MSDSM the object is carried to disabled-failed and its alarm is setted to file unusable value
aaaa = bbbb = Not used Not used

542

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = = = = = = = = = = Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used

cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

Originator = 625 SDRIBSIU The BSC local or central IDT file upload has not been performed successfully; UNLOCK and then LOCK the REMINV object and then perform the upload again
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Source error line Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

##StartSpecProbl##
Specific Problems = 332 WRONG PROCESSOR COPY

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 650 MOSGSUTFH This error occurs when the task is activated on MPCC active copy and not on MPCC standby copy.
A30808-X3247-K240-3-7619 543

Outputs OML:BSC
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

Base Station Controller

##StartSpecProbl##
Specific Problems = 339 FILE MISSING

Event Type = PROCESSING_FAILURE_EVENT Severity = MINOR Proposed Repair Actions = 5 SEE THE PROPOSED ACTION IN THE MANUAL

Originator = 506 MSDSM in the rebuild procedure the object is initialized and its alarm is setted to file missing value
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used

##StartSpecProbl##
Specific Problems = 319 INVALID STATUS WARNING

544

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 124 MOSSDNDDL0, 125 MOSSDNDDL1 This error occours when is requested a download of a DISABLE NEYESUSW
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to indicate file id of first calling instruction Used by the designer to indicate line of first calling instruction Used by the designer to indicate file id of second calling instruction Used by the designer to indicate line of second calling instruction Used by the designer to indicate file id of third calling instruction Used by the designer to indicate line of third calling instruction Used by the designer to indicate file id of fourth calling instruction Used by the designer to indicate line of fourth calling instruction Not used Not used Not used Not used Not used Not used Not used

Originator = 500 MSDLSLTPI, 501 MSDLSLTPL, 502 MSDLSLTPP, 503 MSDLSLTPT This error occurs when: 1-If the originator is 500, is requested a load of a DISABLE RSUEXE for IXLT. processor. 2- If the originator is 501, is requested a load of a DISABLE RSUPCH. 3- If the originator is 502, is requested a load of a DISABLE RSUEXE for PPXX processors. 4- If the originator is 503, is requested a load of a DISABLE RSUEXE for TDPC.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj = = = = = = = = = = Used by the designer to indicate file id of first calling instruction Used by the designer to indicate line of first calling instruction Used by the designer to indicate file id of second calling instruction Used by the designer to indicate line of second calling instruction Used by the designer to indicate file id of third calling instruction Used by the designer to indicate line of third calling instruction Used by the designer to indicate file id of fourth calling instruction Used by the designer to indicate line of fourth calling instruction Not used Not used

A30808-X3247-K240-3-7619

545

Outputs OML:BSC
kkkk llll mmmm nnnn oooo = = = = = Not used Not used Not used Not used Not used

Base Station Controller

##StartSpecProbl##
Specific Problems = 340 BUFFER NOT FOUND

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 5 SEE THE PROPOSED ACTION IN THE MANUAL

Originator = 316 MOSICUTBM An error occurred looking for a buffer to be removed from the list associated to the task.
aaaa = 0x1E TASK_CONTROL_BUFFER_MISSING. 0x21 BUFFER_NOT_FOUND. 0x22 BUFFER_POINTER_NULL. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

= = = = = = = = = = = = = =

546

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

47 SOFTWARE PROGRAM ABNORMALLY TERMINATED


FAILURE EVENT REPORT: NAME = Probable cause = Specific Problems = Event Type = Event Time = Severity = Trend Indication = Notification Identifier = Correlated Notification Identifier = Related MO = Proposed Repair Actions = Additional Text = Originator = Additional Words =
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo <R.T.D.>

<R.T.D.> <R.T.D.> Software Program Abnormally Terminated <see legend> <see legend> <R.T.D.> <see legend> <R.T.D.> <R.T.D.> <displayed only during Alarm Alignment> <R.T.D.> <R.T.D.> <see legend> <R.T.D.> <see legend>

Software Version =

Legend:

##StartSpecProbl##
Specific Problems = 014 TASK ABORTED BY SYSTEM

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 7 MOSFSIOMP, 132 MOSSDFSCS The task (File System or File System Command Handler) has been aborted by the Operating System.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj = = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction). Used by the designer to locate the instruction (line of second calling instruction). Used by the designer to locate the instruction (file id of third calling instruction). Used by the designer to locate the instruction (line of third calling instruction). Used by the designer to locate the instruction (file id of fourth calling instruction). Used by the designer to locate the instruction (line of fourth calling instruction). Not used. Not used.

A30808-X3247-K240-3-7619

547

Outputs OML:BSC
kkkk llll mmmm nnnn oooo = = = = = Not used. Not used. Not used. Not used. Not used.

Base Station Controller

Originator = 318 MOSICUSSC, 505 MSDSMCTMA, 4305 MDH40IOSC The task (Upload Server, Compression or DK40 Device Handler) has been aborted by the Operating System.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to lacate the instruction (line of third calling instruction). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any). Used by the designer to identify the task status Used by the designer to identify the task status Used by the designer to identify the task status Used by the designer to identify the task status Used by the designer to identify the task status Used by the designer to identify the task status Used by the designer to identify the task status

Originator = 500 MSDLSLTPI, 501 MSDLSLTPL, 502 MSDLSLTPP, 503 MSDLSLTPT The task (IXLT load server or patch load server or PPXX load server or TDPC load server) has been aborted by the Operating System.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn = = = = = = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (file line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction). Used by the designer to locate the instruction (file line of second calling instruction). Used by the designer to locate the instruction (file id of third calling instruction). Used by the designer to locate the instruction (file line of third calling instruction). Used by the designer to locate the instruction (file id of fourth calling instruction). Used by the designer to locate the instruction (file line of fourth calling instruction). Not used. Not used. Not used. Not used. Not used. Not used.

548

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
Not used.

oooo =

Originator = 507 MSDBASDL The task (the BSC Agent or a processor controller) has been aborted by the Operating System.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to rebuild the MPCC processor call stack. Used by the designer to rebuild the MPCC processor call stack. Used by the designer to rebuild the MPCC processor call stack. Used by the designer to rebuild the MPCC processor call stack. Used by the designer to rebuild the MPCC processor call stack. Used by the designer to rebuild the MPCC processor call stack. Used by the designer to rebuild the MPCC processor call stack. Used by the designer to rebuild the MPCC processor call stack. Used by the designer to rebuild the MPCC processor call stack. Used by the designer to rebuild the MPCC processor call stack. Used by the designer to rebuild the MPCC processor call stack. Used by the designer to rebuild the MPCC processor call stack. Used by the designer to rebuild the MPCC processor call stack. Used by the designer to rebuild the MPCC processor call stack. Used by the designer to rebuild the MPCC processor call stack.

Originator = 4354 MDHBCABHA This error is issued when the task Bsc Controller has been aborted by the Operating System and a GetInfo command was processing. The additional infos are not meaningful for the operator.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll = = = = = = = = = = = = _LINE_ giServer[].giMan (DHBC local database). giServer[].curlevel (DHBC local database). giserver[].replied (DHBC local database). giServer[].map (DHBC local database). giServer[].repDest (DHBC local database). Not used. Not used. Not used. Not used. Not used. Not used.

A30808-X3247-K240-3-7619

549

Outputs OML:BSC
mmmm = nnnn = oooo = Not used. Not used. Not used.

Base Station Controller

##StartSpecProbl##
Specific Problems = 238 UNABLE TO INITIALIZE

Event Type = PROCESSING FAILURE EVENT Severity = CRITICAL Proposed Repair Actions = 1 NO ACTION

Originator = 4607 MDHPRDDM2 The boot sequence of MPCC at any initialization level fails. The system is unable to run.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Line in the code where the error has been recognized. Code of the occurred error (high). Code of the occurred error (low). Requested initialization level (high). Requested initialization level(low). ME2M configuration. MPCC alarm register. MPCC control point register. MPCC mask register. MPCC sense point register. MPCC GA alarm register. MPCC GA external sense point register. MPCC GA control point register. PIC master mask & in service int. register. PIC slave mask & in service int. register.

Specific Problems = 246 AP TRACE ERROR NOTIFICATION ABNORMAL TERMINATION

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 7100 TL3RDALL A trace activity was abnormally stopped.


aaaa = Process Identifier (see annex D for more details)

550

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = = = = = = = = = = = Process Instance Process State Not Used Process Source Line Trace Error Cause Trace Reference Mobile Identity (see GSM 04.08) Mobile Identity (see GSM 04.08) Mobile Identity (see GSM 04.08) Mobile Identity (see GSM 04.08) Mobile Identity (see GSM 04.08) Not Used Not Used Not Used

bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

A30808-X3247-K240-3-7619

551

Outputs OML:BSC

Base Station Controller

49 STORAGE CAPACITY ERROR


FAILURE EVENT REPORT: NAME = Probable cause = Specific Problems = Event Type = Event Time = Severity = Trend Indication = Notification Identifier = Correlated Notification Identifier = Related MO = Proposed Repair Actions = Additional Text = Originator = Additional Words =
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo <R.T.D.>

<R.T.D.> <R.T.D.> Storage Capacity Error <see legend> <see legend> <R.T.D.> <see legend> <R.T.D.> <R.T.D.> <displayed only during Alarm Alignment> <R.T.D.> <R.T.D.> <see legend> <R.T.D.> <see legend>

Software Version =

Legend:

Specific Problems = 006 INTERWORKING COMMAND TABLE ERROR

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 511 MOSIWROCO,515 MOSIWMEMA,516 MOSIWMEMI,517 MOSIWMEST,518 MOSIWMEAL,519 MOSIWMETE, 520 MOSIWMEME The saved_cmd_info table entry, used to store some information of the commands before sending them toward the Abis-Asub, is busy.
aaaa = bbbb = Source code line Used by the designer to indicate the Error description -TABLE_BUSY .Occurred when saved_cmd_table entry, is busy (another command for same NE is already in progress)

552

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = = = = = = = = = = Used by the designer to indicate the source_sys Used by the designer to indicate the dest_sys Used by the designer to indicate the flags Used by the designer to indicate the source_mbx Used by the designer to indicate the destination Used by the designer to indicate the signal_type Used by the designer to indicate the signal_subtype Used by the designer to indicate the datalen Used by the designer to indicate the operationcode Used by the designer to indicate the message_type Not used. Not used. Not used.

cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo

A30808-X3247-K240-3-7619

553

Outputs OML:BSC

Base Station Controller

50 TEMPERATURE UNACCEPTABLE
FAILURE EVENT REPORT: NAME = Probable cause = Specific Problems = Event Type = Event Time = Severity = Trend Indication = Notification Identifier = Correlated Notification Identifier = Related MO = Proposed Repair Actions = Additional Text = Originator = Additional Words =
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo <R.T.D.>

<R.T.D.> <R.T.D.> Temperature Unacceptable <see legend> <see legend> <R.T.D.> <see legend> <R.T.D.> <R.T.D.> <displayed only during Alarm Alignment> <R.T.D.> <R.T.D.> <see legend> <R.T.D.> <see legend>

Software Version =

Legend:

Specific Problems = 123 TEMPERATURE UNACCEPTABLE ALARM

Event Type = ENVIRONMENTAL FAILURE EVENT Severity = MAJOR Proposed Repair Actions = 6 SEE THE FORESEEN OPERATING COMPANY REPAIR ACTION

Originator = 4001 MDHACENSA The temperature of the environment where the system is located has exceeded (higher or lower than) the acceptable limit.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk = = = = = = = = = = = Developer reserved: code line number where error is emitted Error originator where error was detected Reports the Sense Point number to which the temperature sensor is connected (from 0 to 4). Reports the number of seconds to consider the alarm as true (i.e. the alarm must persist the reported number of seconds to take it into account). Reports the current state of all Sense Points. Reports if the alarm was detecetd on the active copy of Mpcc (1if TRUE , 0 if FALSE) Reports if the alarm was detecetd on the standby copy of Mpcc (1if TRUE , 0 if FALSE). Reports the number of the active Mpcc. not used. not used. not used.

554

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = not used. not used. not used. not used.

llll mmmm nnnn oooo

A30808-X3247-K240-3-7619

555

Outputs OML:BSC

Base Station Controller

56 UNDERLYING RESOURCE NOT AVAILABLE


FAILURE EVENT REPORT: NAME = Probable cause = Specific Problems = Event Type = Event Time = Severity = Trend Indication = Notification Identifier = Correlated Notification Identifier = Related MO = Proposed Repair Actions = Additional Text = Originator = Additional Words =
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo <R.T.D.>

<R.T.D.> <R.T.D.> Underlying Resource Not Available <see legend> <see legend> <R.T.D.> <see legend> <R.T.D.> <R.T.D.> <displayed only during Alarm Alignment> <R.T.D.> <R.T.D.> <see legend> <R.T.D.> <see legend>

Software Version =

Legend:

##StartSpecProbl##
Specific Problems = 008 FILE ALREADY IN USE

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 5 SEE THE PROPOSED ACTION IN THE MANUAL

Originator = 124 MOSSDNDDL0 The BTSE download task can not access a file because already in use. This means that a system operation, that can be in conflict with the BTSE download, is in progress.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj = = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any) Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to locate the instruction (line of third calling instruction, if any). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any). Not used Not used

556

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = = Not used Not used Not used Not used Not used

kkkk llll mmmm nnnn oooo

Originator = 125 MOSSDNDDL1 The TRAU download task can not access a file because already in use. This means that a system operation, that can be in conflict with the TRAU download, is in progress.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to locate the instruction (line of third calling instruction, if any). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any). Not used. Not used. Not used. Not used. Not used. Not used. Not used.

##StartSpecProbl##
Specific Problems = 061 AP NO CHANNEL PRESENT

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 7100 TL3RDALL No channel was found in the cell with the requested channel combination.
aaaa bbbb cccc dddd eeee ffff gggg hhhh = = = = = = = = Process Identifier (see annex D for more details) Process Instance Process State Not used Process Source Line Cell Not Used Not Used

A30808-X3247-K240-3-7619

557

Outputs OML:BSC
iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = Not Used Not Used Not Used Not Used Not Used Not Used Not Used

Base Station Controller

##StartSpecProbl##
Specific Problems = 062 AP NO FREE CHANNELS

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 7100 TL3RDALL All available channels in the cell are BUSY or DISABLE.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Process Identifier (see annex D for more details) Process Instance Process State Not used Process Source Line Cell Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used

##StartSpecProbl##
Specific Problems = 063 AP NO FREE CONNECTIONS

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

558

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Originator = 7100 TL3RDALL During an immediate assignment, no free entry was found in the SCCP connection table.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Process Identifier (see annex D for more details) Process Instance Process State Not Used Process Source Line Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used

##StartSpecProbl##
Specific Problems = 064 AP NO FREE INSTANCE

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 7100 TL3RDALL A Call Register exhaustion is occurred.


aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Process Identifier (see annex D for more details) Process Instance Process State Not Used Process Source Line Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used

A30808-X3247-K240-3-7619

559

Outputs OML:BSC

Base Station Controller

##StartSpecProbl##
Specific Problems = 065 AP NO HANDOVER REFERENCE

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 7100 TL3RDALL The maximum number of simultaneous handover(256) was exceeded.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Process Identifier (see annex D for more details) Process Instance Process State Not Used Process Source Line Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used

##StartSpecProbl##
Specific Problems = 102 UNAVAILABLE RADIO SIGNALLING CHANNELS THRESHOLD MINOR

Event Type = QUALITY OF SERVICE FAILURE EVENT Severity = MINOR Proposed Repair Actions = 1 NO ACTION

Originator = 4700 TDHBFCFMN This error occurs when the minor threshold related to the out of services SDCCH channels (disable or lock), set by the operator with the SET BTS command, is exceeded.
aaaa bbbb cccc dddd = = = = Number of SDCCH channels lost. Value of radio signalling channel threshold. Number of SDCCH channels created. Internal high error code: EC_BCCH_OUTAGE 0x1 EC_NO_BCCH 0x2 EC_FAILED_HOP 0x4 EC_NO_TCH 0x8 EC_NO_SDCCH 0x10 EC_NO_CBCH 0x20 EC_DEGRADED_BARR 0x40 bts degraded for bar causes; EC_DEGRADED_DIV 0x80 bts degraded for diversity

560

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
EC_CRIT_THR 0x400 EC_MAJOR_THR 0x200 EC_MINOR_THR 0x100 EC_RESTART_HOP 0x800 EC_BCCH_FREQ 0x1000 Internal low error code: EC_BCCH_OUTAGE 0x1 EC_NO_BCCH 0x2 EC_FAILED_HOP 0x4 EC_NO_TCH 0x8 EC_NO_SDCCH 0x10 EC_NO_CBCH 0x20 EC_DEGRADED_BARR 0x40 bts degraded for bar causes; EC_DEGRADED_DIV 0x80 bts degraded for diversity EC_CRIT_THR 0x400 EC_MAJOR_THR 0x200 EC_MINOR_THR 0x100 EC_RESTART_HOP 0x800 EC_BCCH_FREQ 0x1000 Btsm number Bts relative number high BAR condition (DHBFI.H): BAR_NO_BTSM 0x1 btsm disabled or locked BAR_NO_BTS 0x2 bts disabled or locked BAR_NO_TRX 0x4 no one trx enabled-unlocked BAR_NO_BCCH 0x8 no bcch currently available BAR_FAILED_BCCH 0x10 bcch trx locked or disabled dep abis BAR_BCCH_DSBL 0x20 keep barred the cell as long as bcch is not enable BAR_NO_SDCCH 0x40 no sdcch currently available BAR_FAILED_SDCCH 0x80 last sdcch trx locked or disabled dep abis BAR_NO_TCH 0x100 no traffic channel available BAR_TCH_DSBL 0x200 keep barred the cell at least a channel is enabled BAR_FAILED_HOP 0x400 hopping trx locked of disable dep abis BAR_FAILED_CBCH 0x800 cbch trx locked or disabled dep abis BAR_STRTM 0x1000 starting time procedure evolving BAR_ENABLE_HOP 0x2000 restart of hopping procedure BAR_BCCH_FREQ 0x4000 bcch frequency change procedure low BAR condition (DHBFI.H): BAR_NO_BTSM 0x1 btsm disabled or locked BAR_NO_BTS 0x2 bts disabled or locked BAR_NO_TRX 0x4 no one trx enabled-unlocked BAR_NO_BCCH 0x8 no bcch currently available BAR_FAILED_BCCH 0x10 bcch trx locked or disabled dep abis BAR_BCCH_DSBL 0x20 keep barred the cell as long as bcch is not enable BAR_NO_SDCCH 0x40 no sdcch currently available BAR_FAILED_SDCCH 0x80 last sdcch trx locked or disabled dep abis BAR_NO_TCH 0x100 no traffic channel available BAR_TCH_DSBL 0x200 keep barred the cell at least a channel is enabled BAR_FAILED_HOP 0x400 hopping trx locked of disable dep abis BAR_FAILED_CBCH 0x800 cbch trx locked or disabled dep abis BAR_STRTM 0x1000 starting time procedure evolving BAR_ENABLE_HOP 0x2000 restart of hopping procedure BAR_BCCH_FREQ 0x4000 bcch frequency change procedure not used not used not used not used not used not used

eeee =

ffff = gggg = hhhh =

iiii =

jjjj kkkk llll mmmm nnnn oooo

= = = = = =

##StartSpecProbl##
A30808-X3247-K240-3-7619 561

Outputs OML:BSC
Specific Problems = 118 UNAVAILABLE RADIO SIGNALLING CHANNELS THRESHOLD MAJOR

Base Station Controller

Event Type = QUALITY OF SERVICE FAILURE EVENT Severity = MAJOR Proposed Repair Actions = 1 NO ACTION

Originator = 4700 TDHBFCFMN This error occurs when the major threshold related to the out of services SDCCH channels (disable or lock), set by the operator with the SET BTS command, is exceeded.
aaaa bbbb cccc dddd = = = = Number of SDCCH channels lost. Value of radio signalling channel threshold. Number of SDCCH channels created. Internal high error code: EC_BCCH_OUTAGE 0x1 EC_NO_BCCH 0x2 EC_FAILED_HOP 0x4 EC_NO_TCH 0x8 EC_NO_SDCCH 0x10 EC_NO_CBCH 0x20 EC_DEGRADED_BARR 0x40 bts degraded for bar causes; EC_DEGRADED_DIV 0x80 bts degraded for diversity EC_CRIT_THR 0x400 EC_MAJOR_THR 0x200 EC_MINOR_THR 0x100 EC_RESTART_HOP 0x800 EC_BCCH_FREQ 0x1000 Internal low error code: EC_BCCH_OUTAGE 0x1 EC_NO_BCCH 0x2 EC_FAILED_HOP 0x4 EC_NO_TCH 0x8 EC_NO_SDCCH 0x10 EC_NO_CBCH 0x20 EC_DEGRADED_BARR 0x40 bts degraded for bar causes; EC_DEGRADED_DIV 0x80 bts degraded for diversity EC_CRIT_THR 0x400 EC_MAJOR_THR 0x200 EC_MINOR_THR 0x100 EC_RESTART_HOP 0x800 EC_BCCH_FREQ 0x1000 Btsm number Bts relative number high BAR condition (DHBFI.H): BAR_NO_BTSM 0x1 btsm disabled or locked BAR_NO_BTS 0x2 bts disabled or locked BAR_NO_TRX 0x4 no one trx enabled-unlocked BAR_NO_BCCH 0x8 no bcch currently available BAR_FAILED_BCCH 0x10 bcch trx locked or disabled dep abis BAR_BCCH_DSBL 0x20 keep barred the cell as long as bcch is not enable BAR_NO_SDCCH 0x40 no sdcch currently available BAR_FAILED_SDCCH 0x80 last sdcch trx locked or disabled dep abis BAR_NO_TCH 0x100 no traffic channel available BAR_TCH_DSBL 0x200 keep barred the cell at least a channel is enabled BAR_FAILED_HOP 0x400 hopping trx locked of disable dep abis BAR_FAILED_CBCH 0x800 cbch trx locked or disabled dep abis BAR_STRTM 0x1000 starting time procedure evolving BAR_ENABLE_HOP 0x2000 restart of hopping procedure BAR_BCCH_FREQ 0x4000 bcch frequency change procedure low BAR condition (DHBFI.H): BAR_NO_BTSM 0x1 btsm disabled or locked BAR_NO_BTS 0x2 bts disabled or locked BAR_NO_TRX 0x4 no one trx enabled-unlocked

eeee =

ffff = gggg = hhhh =

iiii =

562

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
BAR_NO_BCCH 0x8 BAR_FAILED_BCCH 0x10 BAR_BCCH_DSBL 0x20 BAR_NO_SDCCH 0x40 BAR_FAILED_SDCCH 0x80 BAR_NO_TCH 0x100 BAR_TCH_DSBL 0x200 BAR_FAILED_HOP 0x400 BAR_FAILED_CBCH 0x800 BAR_STRTM 0x1000 BAR_ENABLE_HOP 0x2000 BAR_BCCH_FREQ 0x4000 not used not used not used not used not used not used no bcch currently available bcch trx locked or disabled dep abis keep barred the cell as long as bcch is not enable no sdcch currently available last sdcch trx locked or disabled dep abis no traffic channel available keep barred the cell at least a channel is enabled hopping trx locked of disable dep abis cbch trx locked or disabled dep abis starting time procedure evolving restart of hopping procedure bcch frequency change procedure

jjjj kkkk llll mmmm nnnn oooo

= = = = = =

##StartSpecProbl##
Specific Problems = 156 UNAVAILABLE RADIO SIGNALLING CHANNELS THRESHOLD CRITICAL

Event Type = QUALITY OF SERVICE FAILURE EVENT Severity = CRITICAL Proposed Repair Actions = 1 NO ACTION

Originator = 4700 TDHBFCFMN This error occurs when the critical threshold related to the out of services SDCCH channels (disable or lock), set by the operator with the SET BTS command, is exceeded.
aaaa bbbb cccc dddd = = = = Number of SDCCH channels lost. Value of radio signalling channel threshold. Number of SDCCH channels created. Internal high error code: EC_BCCH_OUTAGE 0x1 EC_NO_BCCH 0x2 EC_FAILED_HOP 0x4 EC_NO_TCH 0x8 EC_NO_SDCCH 0x10 EC_NO_CBCH 0x20 EC_DEGRADED_BARR 0x40 bts degraded for bar causes; EC_DEGRADED_DIV 0x80 bts degraded for diversity EC_CRIT_THR 0x400 EC_MAJOR_THR 0x200 EC_MINOR_THR 0x100 EC_RESTART_HOP 0x800 EC_BCCH_FREQ 0x1000 Internal low error code: EC_BCCH_OUTAGE 0x1 EC_NO_BCCH 0x2 EC_FAILED_HOP 0x4 EC_NO_TCH 0x8 EC_NO_SDCCH 0x10 EC_NO_CBCH 0x20 EC_DEGRADED_BARR 0x40 bts degraded for bar causes;

eeee =

A30808-X3247-K240-3-7619

563

Outputs OML:BSC
EC_DEGRADED_DIV 0x80 EC_CRIT_THR 0x400 EC_MAJOR_THR 0x200 EC_MINOR_THR 0x100 EC_RESTART_HOP 0x800 EC_BCCH_FREQ 0x1000 Btsm number Bts relative number high BAR condition (DHBFI.H): BAR_NO_BTSM 0x1 BAR_NO_BTS 0x2 BAR_NO_TRX 0x4 BAR_NO_BCCH 0x8 BAR_FAILED_BCCH 0x10 BAR_BCCH_DSBL 0x20 BAR_NO_SDCCH 0x40 BAR_FAILED_SDCCH 0x80 BAR_NO_TCH 0x100 BAR_TCH_DSBL 0x200 BAR_FAILED_HOP 0x400 BAR_FAILED_CBCH 0x800 BAR_STRTM 0x1000 BAR_ENABLE_HOP 0x2000 BAR_BCCH_FREQ 0x4000 low BAR condition (DHBFI.H): BAR_NO_BTSM 0x1 BAR_NO_BTS 0x2 BAR_NO_TRX 0x4 BAR_NO_BCCH 0x8 BAR_FAILED_BCCH 0x10 BAR_BCCH_DSBL 0x20 BAR_NO_SDCCH 0x40 BAR_FAILED_SDCCH 0x80 BAR_NO_TCH 0x100 BAR_TCH_DSBL 0x200 BAR_FAILED_HOP 0x400 BAR_FAILED_CBCH 0x800 BAR_STRTM 0x1000 BAR_ENABLE_HOP 0x2000 BAR_BCCH_FREQ 0x4000 not used not used not used not used not used not used bts degraded for diversity

Base Station Controller

ffff = gggg = hhhh =

btsm disabled or locked bts disabled or locked no one trx enabled-unlocked no bcch currently available bcch trx locked or disabled dep abis keep barred the cell as long as bcch is not enable no sdcch currently available last sdcch trx locked or disabled dep abis no traffic channel available keep barred the cell at least a channel is enabled hopping trx locked of disable dep abis cbch trx locked or disabled dep abis starting time procedure evolving restart of hopping procedure bcch frequency change procedure btsm disabled or locked bts disabled or locked no one trx enabled-unlocked no bcch currently available bcch trx locked or disabled dep abis keep barred the cell as long as bcch is not enable no sdcch currently available last sdcch trx locked or disabled dep abis no traffic channel available keep barred the cell at least a channel is enabled hopping trx locked of disable dep abis cbch trx locked or disabled dep abis starting time procedure evolving restart of hopping procedure bcch frequency change procedure

iiii =

jjjj kkkk llll mmmm nnnn oooo

= = = = = =

##StartSpecProbl##
Specific Problems = 164 UNAVAILABLE ABIS TCH THRESHOLD MINOR

Event Type = QUALITY OF SERVICE FAILURE EVENT Severity = MINOR Proposed Repair Actions = 1 NO ACTION

Originator = 4700 TDHBFCFMN

564

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

This error occurs when the minor threshold related to the out of services traffic channels (disable or lock), set by the operator with the SET BTS command, is exceeded.
aaaa bbbb cccc dddd = = = = Number of traffic channels lost Value of channel threshold. Number of traffic channels created. Internal high error code: EC_BCCH_OUTAGE 0x1 EC_NO_BCCH 0x2 EC_FAILED_HOP 0x4 EC_NO_TCH 0x8 EC_NO_SDCCH 0x10 EC_NO_CBCH 0x20 EC_DEGRADED_BARR 0x40 bts degraded for bar causes; EC_DEGRADED_DIV 0x80 bts degraded for diversity EC_CRIT_THR 0x400 EC_MAJOR_THR 0x200 EC_MINOR_THR 0x100 EC_RESTART_HOP 0x800 EC_BCCH_FREQ 0x1000 Internal low error code: EC_BCCH_OUTAGE 0x1 EC_NO_BCCH 0x2 EC_FAILED_HOP 0x4 EC_NO_TCH 0x8 EC_NO_SDCCH 0x10 EC_NO_CBCH 0x20 EC_DEGRADED_BARR 0x40 bts degraded for bar causes; EC_DEGRADED_DIV 0x80 bts degraded for diversity EC_CRIT_THR 0x400 EC_MAJOR_THR 0x200 EC_MINOR_THR 0x100 EC_RESTART_HOP 0x800 EC_BCCH_FREQ 0x1000 Btsm number Bts relative number high BAR condition (DHBFI.H): BAR_NO_BTSM 0x1 btsm disabled or locked BAR_NO_BTS 0x2 bts disabled or locked BAR_NO_TRX 0x4 no one trx enabled-unlocked BAR_NO_BCCH 0x8 no bcch currently available BAR_FAILED_BCCH 0x10 bcch trx locked or disabled dep abis BAR_BCCH_DSBL 0x20 keep barred the cell as long as bcch is not enable BAR_NO_SDCCH 0x40 no sdcch currently available BAR_FAILED_SDCCH 0x80 last sdcch trx locked or disabled dep abis BAR_NO_TCH 0x100 no traffic channel available BAR_TCH_DSBL 0x200 keep barred the cell at least a channel is enabled BAR_FAILED_HOP 0x400 hopping trx locked of disable dep abis BAR_FAILED_CBCH 0x800 cbch trx locked or disabled dep abis BAR_STRTM 0x1000 starting time procedure evolving BAR_ENABLE_HOP 0x2000 restart of hopping procedure BAR_BCCH_FREQ 0x4000 bcch frequency change procedure low BAR condition (DHBFI.H): BAR_NO_BTSM 0x1 btsm disabled or locked BAR_NO_BTS 0x2 bts disabled or locked BAR_NO_TRX 0x4 no one trx enabled-unlocked BAR_NO_BCCH 0x8 no bcch currently available BAR_FAILED_BCCH 0x10 bcch trx locked or disabled dep abis BAR_BCCH_DSBL 0x20 keep barred the cell as long as bcch is not enable BAR_NO_SDCCH 0x40 no sdcch currently available BAR_FAILED_SDCCH 0x80 last sdcch trx locked or disabled dep abis BAR_NO_TCH 0x100 no traffic channel available BAR_TCH_DSBL 0x200 keep barred the cell at least a channel is enabled BAR_FAILED_HOP 0x400 hopping trx locked of disable dep abis BAR_FAILED_CBCH 0x800 cbch trx locked or disabled dep abis BAR_STRTM 0x1000 starting time procedure evolving BAR_ENABLE_HOP 0x2000 restart of hopping procedure BAR_BCCH_FREQ 0x4000 bcch frequency change procedure

eeee =

ffff = gggg = hhhh =

iiii =

A30808-X3247-K240-3-7619

565

Outputs OML:BSC
jjjj kkkk llll mmmm nnnn oooo = = = = = = not used not used not used not used not used not used

Base Station Controller

##StartSpecProbl##
Specific Problems = 165 UNAVAILABLE ABIS TCH THRESHOLD MAJOR

Event Type = QUALITY OF SERVICE FAILURE EVENT Severity = MAJOR Proposed Repair Actions = 1 NO ACTION

Originator = 4700 TDHBFCFMN This error occurs when the major threshold related to the out of service traffic channels (disabled or locked), set by the operator with the SET BTS command, is exceeded.
aaaa bbbb cccc dddd = = = = Number of traffic channels lost. Value of channel threshold. Number of traffic channels created. Internal high error code: EC_BCCH_OUTAGE 0x1 EC_NO_BCCH 0x2 EC_FAILED_HOP 0x4 EC_NO_TCH 0x8 EC_NO_SDCCH 0x10 EC_NO_CBCH 0x20 EC_DEGRADED_BARR 0x40 bts degraded for bar causes; EC_DEGRADED_DIV 0x80 bts degraded for diversity EC_CRIT_THR 0x400 EC_MAJOR_THR 0x200 EC_MINOR_THR 0x100 EC_RESTART_HOP 0x800 EC_BCCH_FREQ 0x1000 Internal low error code: EC_BCCH_OUTAGE 0x1 EC_NO_BCCH 0x2 EC_FAILED_HOP 0x4 EC_NO_TCH 0x8 EC_NO_SDCCH 0x10 EC_NO_CBCH 0x20 EC_DEGRADED_BARR 0x40 bts degraded for bar causes; EC_DEGRADED_DIV 0x80 bts degraded for diversity EC_CRIT_THR 0x400 EC_MAJOR_THR 0x200 EC_MINOR_THR 0x100 EC_RESTART_HOP 0x800 EC_BCCH_FREQ 0x1000 Btsm number Bts relative number high BAR condition (DHBFI.H): BAR_NO_BTSM 0x1 btsm disabled or locked BAR_NO_BTS 0x2 bts disabled or locked BAR_NO_TRX 0x4 no one trx enabled-unlocked

eeee =

ffff = gggg = hhhh =

566

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
BAR_NO_BCCH 0x8 BAR_FAILED_BCCH 0x10 BAR_BCCH_DSBL 0x20 BAR_NO_SDCCH 0x40 BAR_FAILED_SDCCH 0x80 BAR_NO_TCH 0x100 BAR_TCH_DSBL 0x200 BAR_FAILED_HOP 0x400 BAR_FAILED_CBCH 0x800 BAR_STRTM 0x1000 BAR_ENABLE_HOP 0x2000 BAR_BCCH_FREQ 0x4000 low BAR condition (DHBFI.H): BAR_NO_BTSM 0x1 BAR_NO_BTS 0x2 BAR_NO_TRX 0x4 BAR_NO_BCCH 0x8 BAR_FAILED_BCCH 0x10 BAR_BCCH_DSBL 0x20 BAR_NO_SDCCH 0x40 BAR_FAILED_SDCCH 0x80 BAR_NO_TCH 0x100 BAR_TCH_DSBL 0x200 BAR_FAILED_HOP 0x400 BAR_FAILED_CBCH 0x800 BAR_STRTM 0x1000 BAR_ENABLE_HOP 0x2000 BAR_BCCH_FREQ 0x4000 not used not used not used not used not used not used no bcch currently available bcch trx locked or disabled dep abis keep barred the cell as long as bcch is not enable no sdcch currently available last sdcch trx locked or disabled dep abis no traffic channel available keep barred the cell at least a channel is enabled hopping trx locked of disable dep abis cbch trx locked or disabled dep abis starting time procedure evolving restart of hopping procedure bcch frequency change procedure btsm disabled or locked bts disabled or locked no one trx enabled-unlocked no bcch currently available bcch trx locked or disabled dep abis keep barred the cell as long as bcch is not enable no sdcch currently available last sdcch trx locked or disabled dep abis no traffic channel available keep barred the cell at least a channel is enabled hopping trx locked of disable dep abis cbch trx locked or disabled dep abis starting time procedure evolving restart of hopping procedure bcch frequency change procedure

iiii =

jjjj kkkk llll mmmm nnnn oooo

= = = = = =

##StartSpecProbl##
Specific Problems = 166 UNAVAILABLE ABIS TCH THRESHOLD CRITICAL

Event Type = QUALITY OF SERVICE FAILURE EVENT Severity = CRITICAL Proposed Repair Actions = 1 NO ACTION

Originator = 4700 TDHBFCFMN This error occurs when the critical threshold related to the out of services traffic channels (disable or lock), set by the operator with the SET BTS command, is exceeded.
aaaa bbbb cccc dddd = = = = Number of traffic channels lost. Value of channel threshold. Number of traffic channels created. Internal high error code: EC_BCCH_OUTAGE 0x1 EC_NO_BCCH 0x2 EC_FAILED_HOP 0x4 EC_NO_TCH 0x8 EC_NO_SDCCH 0x10

A30808-X3247-K240-3-7619

567

Outputs OML:BSC
EC_NO_CBCH 0x20 EC_DEGRADED_BARR 0x40 EC_DEGRADED_DIV 0x80 EC_CRIT_THR 0x400 EC_MAJOR_THR 0x200 EC_MINOR_THR 0x100 EC_RESTART_HOP 0x800 EC_BCCH_FREQ 0x1000 Internal low error code: EC_BCCH_OUTAGE 0x1 EC_NO_BCCH 0x2 EC_FAILED_HOP 0x4 EC_NO_TCH 0x8 EC_NO_SDCCH 0x10 EC_NO_CBCH 0x20 EC_DEGRADED_BARR 0x40 EC_DEGRADED_DIV 0x80 EC_CRIT_THR 0x400 EC_MAJOR_THR 0x200 EC_MINOR_THR 0x100 EC_RESTART_HOP 0x800 EC_BCCH_FREQ 0x1000 Btsm number Bts relative number high BAR condition (DHBFI.H): BAR_NO_BTSM 0x1 BAR_NO_BTS 0x2 BAR_NO_TRX 0x4 BAR_NO_BCCH 0x8 BAR_FAILED_BCCH 0x10 BAR_BCCH_DSBL 0x20 BAR_NO_SDCCH 0x40 BAR_FAILED_SDCCH 0x80 BAR_NO_TCH 0x100 BAR_TCH_DSBL 0x200 BAR_FAILED_HOP 0x400 BAR_FAILED_CBCH 0x800 BAR_STRTM 0x1000 BAR_ENABLE_HOP 0x2000 BAR_BCCH_FREQ 0x4000 low BAR condition (DHBFI.H): BAR_NO_BTSM 0x1 BAR_NO_BTS 0x2 BAR_NO_TRX 0x4 BAR_NO_BCCH 0x8 BAR_FAILED_BCCH 0x10 BAR_BCCH_DSBL 0x20 BAR_NO_SDCCH 0x40 BAR_FAILED_SDCCH 0x80 BAR_NO_TCH 0x100 BAR_TCH_DSBL 0x200 BAR_FAILED_HOP 0x400 BAR_FAILED_CBCH 0x800 BAR_STRTM 0x1000 BAR_ENABLE_HOP 0x2000 BAR_BCCH_FREQ 0x4000 not used not used not used not used not used not used bts degraded for bar causes; bts degraded for diversity

Base Station Controller

eeee =

bts degraded for bar causes; bts degraded for diversity

ffff = gggg = hhhh =

btsm disabled or locked bts disabled or locked no one trx enabled-unlocked no bcch currently available bcch trx locked or disabled dep abis keep barred the cell as long as bcch is not enable no sdcch currently available last sdcch trx locked or disabled dep abis no traffic channel available keep barred the cell at least a channel is enabled hopping trx locked of disable dep abis cbch trx locked or disabled dep abis starting time procedure evolving restart of hopping procedure bcch frequency change procedure btsm disabled or locked bts disabled or locked no one trx enabled-unlocked no bcch currently available bcch trx locked or disabled dep abis keep barred the cell as long as bcch is not enable no sdcch currently available last sdcch trx locked or disabled dep abis no traffic channel available keep barred the cell at least a channel is enabled hopping trx locked of disable dep abis cbch trx locked or disabled dep abis starting time procedure evolving restart of hopping procedure bcch frequency change procedure

iiii =

jjjj kkkk llll mmmm nnnn oooo

= = = = = =

568

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

##StartSpecProbl##
Specific Problems = 225 UNAVAILABLE AINT TCH THRESHOLD MINOR

Event Type = QUALITY OF SERVICE FAILURE EVENT Severity = MINOR Proposed Repair Actions = 1 NO ACTION

Originator = 3111 MSMSHHDHT The percentage of TSLA out of service has exceeded the value defined by operator as minor threshold.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Number of TSLA out of service. Number of SS7L-MSC out of service. Number of SS7L-LCS out of service. Number of TSLA equipped. Number of SS7L-MSC equipped. Number of SS7L-LCS equipped. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

##StartSpecProbl##
Specific Problems = 226 UNAVAILABLE AINT TCH THRESHOLD MAJOR

Event Type = QUALITY OF SERVICE FAILURE EVENT Severity = MAJOR Proposed Repair Actions = 1 NO ACTION

Originator = 3111 MSMSHHDHT The percentage of TSLA out of service has exceeded the value defined by operator as major threshold.
aaaa bbbb cccc dddd eeee ffff gggg hhhh = = = = = = = = Number of TSLA out of service. Number of SS7L-MSC out of service. Number of SS7L-LCS out of service. Number of TSLA equipped. Number of SS7L-MSC equipped. Number of SS7L-LCS equipped. Not used. Not used.

A30808-X3247-K240-3-7619

569

Outputs OML:BSC
iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = Not used. Not used. Not used. Not used. Not used. Not used. Not used.

Base Station Controller

##StartSpecProbl##
Specific Problems = 227 UNAVAILABLE AINT TCH THRESHOLD CRITICAL

Event Type = QUALITY OF SERVICE FAILURE EVENT Severity = CRITICAL Proposed Repair Actions = 1 NO ACTION

Originator = 3111 MSMSHHDHT The percentage of TSLA out of service has exceeded the value defined by operator as critical threshold.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Number of TSLA out of service. Number of SS7L-MSC out of service. Number of SS7L-LCS out of service. Number of TSLA equipped. Number of SS7L-MSC equipped. Number of SS7L-LCS equipped. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

##StartSpecProbl##
Specific Problems = 230 MPCC OUTAGE

Event Type = QUALITY OF SERVICE FAILURE EVENT Severity = CRITICAL Proposed Repair Actions = 1 NO ACTION

570

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Originator = 3111 MSMSHHDHT Both MPCC cards functionality is lost.


aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Process Source Line. MPCC 0 card state. MPCC 1 card state. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

Originator = 4605 MDHPRININ A task init is executed on the active MPCC, it could be spontaneous or induced by a fault on the active copy, but the current active MPCC is locked or it has some problem. The system state is unstable.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Line in the code where the error has been recognized. Not used. Not used. Active MPCC administrative state. Active MPCC operational state. ME2M configuration. MPCC alarm register. MPCC control point register. MPCC mask register. MPCC sense point register. MPCC GA alarm register. MPCC GA external sense point register. MPCC GA control point register. PIC master mask & in service int. register. PIC slave mask & in service int. register.

##StartSpecProbl##
Specific Problems = 231 TDPC OUTAGE

Event Type = QUALITY OF SERVICE FAILURE EVENT Severity = CRITICAL Proposed Repair Actions = 1 NO ACTION
A30808-X3247-K240-3-7619 571

Outputs OML:BSC

Base Station Controller

Originator = 3111 MSMSHHDHT Both TDPC cards functionality is lost.


aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Process Source Line. TDPC 0 card state. TDPC 1 card state. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

Originator = 4604 MDHPRDCSM A disable command has been asked against the last TDPC card available.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Line in the code where the error has been recognized. TDPC number. TDPC number. Orig ME mnemonic. Force parameter. ME2M configuration. MPCC alarm register. MPCC control point register. MPCC mask register. MPCC sense point register. MPCC GA alarm register. MPCC GA external sense point register. MPCC GA control point register. PIC master mask & in service int. register. PIC slave mask & in service int. register.

##StartSpecProbl##
Specific Problems = 233 MEMT OUTAGE

Event Type = QUALITY OF SERVICE FAILURE EVENT


572 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Severity = CRITICAL Proposed Repair Actions = 1 NO ACTION

Originator = 3111 MSMSHHDHT Both MEMT cards functionality is lost.


aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Process Source Line. MEMT 0 card state. MEMT 1 card state. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

Originator = 4603 MDHPRDCUT The last MEMT card available is lost, it could happens due to an hw failure during the normal exercise, or during the initialization sequence.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Line in the code where the error has been recognized. Code of the occurred error (high). Code of the occurred error (low). Result of last hw check on both MEMT cards. Result of last hw check on both MEMT cards. ME2M configuration. MPCC alarm register. MPCC control point register. MPCC mask register. MPCC sense point register. MPCC GA alarm register. MPCC GA external sense point register. MPCC GA control point register. PIC master mask & in service int. register. PIC slave mask & in service int. register.

A30808-X3247-K240-3-7619

573

Outputs OML:BSC

Base Station Controller

##StartSpecProbl##
Specific Problems = 234 DISK OUTAGE

Event Type = QUALITY OF SERVICE FAILURE EVENT Severity = CRITICAL Proposed Repair Actions = 1 NO ACTION

Originator = 3111 MSMSHHDHT Both DISK cards functionality is lost.


aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Process Source Line. DISK 0 card state. DISK 1 card state. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

##StartSpecProbl##
Specific Problems = 235 IXLT OUTAGE

Event Type = QUALITY OF SERVICE FAILURE EVENT Severity = CRITICAL Proposed Repair Actions = 1 NO ACTION

Originator = 3111 MSMSHHDHT Both IXLT cards functionality is lost.


aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll = = = = = = = = = = = = Process Source Line. IXLT 0 card state. IXLT 1 card state. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

574

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
Not used. Not used. Not used.

mmmm = nnnn = oooo =

##StartSpecProbl##
Specific Problems = 236 NTW OUTAGE

Event Type = QUALITY OF SERVICE FAILURE EVENT Severity = CRITICAL Proposed Repair Actions = 1 NO ACTION

Originator = 3111 MSMSHHDHT Both NTW cards functionality is lost.


aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Process Source Line. NTW 0 card state. NTW 1 card state. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

##StartSpecProbl##
Specific Problems = 241 EPWR OUTAGE

Event Type = QUALITY OF SERVICE FAILURE EVENT Severity = CRITICAL Proposed Repair Actions = 1 NO ACTION

Originator = 3111 MSMSHHDHT Both EPWR cards functionality is lost.


aaaa = bbbb = Process Source Line. EPWR 0 card state.

A30808-X3247-K240-3-7619

575

Outputs OML:BSC
cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = EPWR 1 card state. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

Base Station Controller

##StartSpecProbl##
Specific Problems = 242 PPCC OUTAGE

Event Type = QUALITY OF SERVICE FAILURE EVENT Severity = CRITICAL Proposed Repair Actions = 1 NO ACTION

Originator = 3111 MSMSHHDHT Both PPCC cards functionality is lost.


aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Process Source Line. PPCC 0 card state. PPCC 1 card state. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

##StartSpecProbl##
Specific Problems = 244 AP TRACE ERROR NOTIFICATION UNAVAILABILITY

Event Type = PROCESSING FAILURE EVENT


576 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 7100 TL3RDALL A Trace Activity cannot be started due to: - no more free trace entries (7 traces currently active); - Trace Control Object is not created, or locked, or shutting down, or disabled.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Process Identifier (see annex D for more details) Process Instance Process State Not Used Process Source Line Trace Error Cause Trace Reference Mobile Identity (see GSM 04.08) Mobile Identity (see GSM 04.08) Mobile Identity (see GSM 04.08) Mobile Identity (see GSM 04.08) Mobile Identity (see GSM 04.08) Not Used Not Used Not Used

##StartSpecProbl##
Specific Problems = 247 FUNCTIONALITY LOST

Event Type = QUALITY OF SERVICE FAILURE EVENT Severity = CRITICAL Proposed Repair Actions = 1 NO ACTION

Originator = 4706 TDHBFDCSM Every time a BTS object changes its operational state from ENABLED to DISABLED this failure is issued. This error, with a severity CRITICAL, replace the BCCH_OUTAGE failure.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll = = = = = = = = = = = = orig_act: the action that triggered the BTS status change. orig_meid: the object menmonic that triggered the BTS status change. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

A30808-X3247-K240-3-7619

577

Outputs OML:BSC
mmmm = nnnn = oooo = Not used. Not used. Not used.

Base Station Controller

Originator = 4753 TDHTRDCSM Every time a TRAU object changes its operational state from ENABLED to DISABLED the new FUNCTIONALITY_LOST failure event report is issued.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = input command. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

Originator = 4953 TDHGPIHGB If a NSVC remains offline after the initialization, the FUNCTIONALITY LOST failure event report is iussed on all PTPPKFs involved.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = the line number of source module Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used

578

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Originator = 4954 TDHGPIHSM Every time a object changes its operational state from ENABLED to DISABLED the FUNCTIONALITY LOST failure event report is iussed.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = the line number of the source module Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used

Originator = 4955 TDHGPIHL3 On PTPPKF creation, if no NSVC is available, the FUNCTIONALITY LOST failure event report is issued.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = the line number of the source module Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used

A30808-X3247-K240-3-7619

579

Outputs OML:BSC

Base Station Controller

##StartSpecProbl##
Specific Problems = 251 SYNE OUTAGE

Event Type = QUALITY OF SERVICE FAILURE EVENT Severity = CRITICAL Proposed Repair Actions = 1 NO ACTION

Originator = 4208 MDHNWDCSY This error is generated by the BSC when non more external synchronismus signal (SYNE) is available, automatic ceased as soon as a single external source is available again.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = (designer oriented) source line code where the error is issued Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used

##StartSpecProbl##
Specific Problems = 253 SS7S FAILURE

Event Type = COMMUNICATION FAILURE EVENT Severity = CRITICAL Proposed Repair Actions = 1 NO ACTION

Originator = 7059 TL3N7LMLC1 There are not ss7 links available


aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj = = = = = = = = = = Istance Code of message (see annex D for more details) Source line where the error occurred Not used Not used Not used Not used Not used Not used Not used

580

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC
= = = = = Not used Not used Not used Not used Not used

kkkk llll mmmm nnnn oooo

##StartSpecProbl##
Specific Problems = 258 OMAL OUTAGE

Event Type = QUALITY OF SERVICE FAILURE EVENT Severity = CRITICAL Proposed Repair Actions = 1 NO ACTION

Originator = 3111 MSMSHHDHT Both OMAL functionality is lost


aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = source line Omal-0 state value omal-1 state value Not Used. Not Used. Not Used. Not Used. Not Used. Not Used. Not Used. Not Used. Not Used. Not Used. Not Used. Not Used.

##StartSpecProbl##
Specific Problems = 259 CBCL OUTAGE

Event Type = QUALITY OF SERVICE FAILURE EVENT Severity = CRITICAL Proposed Repair Actions = 1 NO ACTION

Originator = 3111 MSMSHHDHT Both CBCL functionality is lost


A30808-X3247-K240-3-7619 581

Outputs OML:BSC
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Source line CBCL-0 state value CBCL-1 state value Not Used. Not Used. Not Used. Not Used. Not Used. Not Used. Not Used. Not Used. Not Used. Not Used. Not Used. Not Used.

Base Station Controller

Specific Problems = 260 X25 OUTAGE

Event Type = QUALITY OF SERVICE FAILURE EVENT Severity = CRITICAL Proposed Repair Actions = 1 NO ACTION

Originator = 3111 MSMSHHDHT Both X25 functionality is lost


aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Source line X25A/D-0 state value X25A/D-1 state value Not Used. Not Used. Not Used. Not Used. Not Used. Not Used. Not Used. Not Used. Not Used. Not Used. Not Used. Not Used.

582

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

57 VERSION MISMATCH
FAILURE EVENT REPORT: NAME = Probable cause = Specific Problems = Event Type = Event Time = Severity = Trend Indication = Notification Identifier = Correlated Notification Identifier = Related MO = Proposed Repair Actions = Additional Text = Originator = Additional Words =
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo <R.T.D.>

<R.T.D.> <R.T.D.> Version Mismatch <see legend> <see legend> <R.T.D.> <see legend> <R.T.D.> <R.T.D.> <displayed only during Alarm Alignment> <R.T.D.> <R.T.D.> <see legend> <R.T.D.> <see legend>

Software Version =

Legend:

##StartSpecProbl##
Specific Problems = 007 SOFTWARE NOT ALIGNED

Event Type = PROCESSING FAILURE EVENT Severity = WARNING Proposed Repair Actions = 1 NO ACTION

Originator = 126 MOSSDNSBL The BTSE alignment task has found out that the software of some NE is not aligned.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk = = = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to locate the instruction (line of third calling instruction, if any). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any). NE whose alignment has failed. Not used. Not used.

A30808-X3247-K240-3-7619

583

Outputs OML:BSC
llll mmmm nnnn oooo = = = = Not used. Not used. Not used. Not used.

Base Station Controller

Originator = 127 MOSSDNSTL The TRAU alignment task has found out that the software of some NE is not aligned.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to locate the instruction (file id of first calling instruction). Used by the designer to locate the instruction (line of first calling instruction). Used by the designer to locate the instruction (file id of second calling instruction, if any). Used by the designer to locate the instruction (line of second calling instruction, if any). Used by the designer to locate the instruction (file id of third calling instruction, if any). Used by the designer to locate the instruction (line of third calling instruction, if any). Used by the designer to locate the instruction (file id of fourth calling instruction, if any). Used by the designer to locate the instruction (line of fourth calling instruction, if any). NE whose alignment has failed. Not used. Not used. Not used. Not used. Not used. Not used.

Originator = 507 MSDBASDL The BSC Agent task has found out that the software of some BSC cards is not aligned or that, when a bring up initialization was requested by the User, the attributes runningESU and backupESU of the object BSCOSUSW are different.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = Used by the designer to rebuild the MPCC processor call stack Used by the designer to rebuild the MPCC processor call stack Used by the designer to rebuild the MPCC processor call stack Used by the designer to rebuild the MPCC processor call stack Used by the designer to rebuild the MPCC processor call stack Used by the designer to rebuild the MPCC processor call stack Used by the designer to rebuild the MPCC processor call stack Used by the designer to rebuild the MPCC processor call stack Used by the designer to rebuild the MPCC processor call stack Used by the designer to rebuild the MPCC processor call stack Used by the designer to rebuild the MPCC processor call stack Used by the designer to rebuild the MPCC processor call stack Used by the designer to rebuild the MPCC processor call stack Used by the designer to rebuild the MPCC processor call stack Used by the designer to rebuild the MPCC processor call stack

584

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Specific Problems = 228 IXLT CARD RESET Event Type = PROCESSING FAILURE EVENT

Severity = MAJOR Proposed Repair Actions = 1 NO ACTION

Originator = 4455 MDHIXDCUF this error occurs when the IXLT card is reset since the current loaded SW does not match with the expected one.
aaaa bbbb cccc dddd eeee ffff gggg hhhh iiii jjjj kkkk llll mmmm nnnn oooo = = = = = = = = = = = = = = = not used. not used. not used. not used. not used. not used. not used. not used. not used. not used. not used. not used. not used. not used. not used.

A30808-X3247-K240-3-7619

585

Outputs OML:BSC

Base Station Controller

Annex A

OBJECT DESCRIPTION list


OBJECT DESCRIPTION ============================================================================= MM_NONE TEST class SBS_BSC: BSC BSCESUDB BSCESUSW NEYESUSW RSUDB RSUEXE RSUEXEA RSUPCH RSUPCHA REMINV SCA SCAA SCAN SCANBSC SCANBTS SCANBTSE SCANBTSIHO SCANBTSM SCANBTSHOI SCANBTSHON SCANCHAN SCANCTRX SCANGPRS SCANSS7L SCANTRX class SBS_EQUIPMENT: BSCE BTSE CTRCO CTRSCHED DK40 ENVA EPWR FRL IXLT
586

mnemonic null = 0x7FFF identifies diagnostic elements

It identifies the whole network element BSC from the software point of view. BSC Executable Software Unit for Database files BSC Executable Software Unit for Generic Software BSC Executable Software Unit for BTS/TRAU Software BSC Replaceable Software Unit for Database file BSC Replaceable Software Unit for a generic executable file BSC auxiliary Replaceable Software Unit for a generic executable file BSC Replaceable Software Unit for a patch file BSC auxiliary Replaceable Software Unit for a patch file Remote Inventory object identifier BSC Smart Carrier Allocation BSC auxiliary Smart Carrier Allocation BSC Scanner generic object identifier BSC Scanner BSC Scanner for BTS BSC Scanner for BTSE BSC Scanner for BTS Hopping BSC Scanner for BTSM BSC Scanner for BTS Hopping BSC Scanner for BTS Hopping BSC Scanner for CHAN BSC Scanner for TRX BSC Scanner for GPRS BSC Scanner for SS7L BSC Scanner for TRX

It identifies the whole network element BSC from the equipment point of view. It identifies the whole network element BTS from the equipment point of view. BSC Control object identifier BSC Control schedule object identifier File system function BSC Environmental alarms identifier Power supply of extended rack GPRS Frame Relay Link identifier OMC and local terminal interface
A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

OBJECT DESCRIPTION ============================================================================= LICD LICDS MEMT MPCC NTW NSVC NUC PCU PLLH PPCC PPCU PPLD PTPPKF PTPPKFA PWRD SCAN SN16 SN64 SYNC SYNE TDPC TRAUE UBEX class SBS_BTS: BTS BTSA class SBS_SIGNALLINGLINK: LNKA SS7L class SBS_ALARMMONITOR: AINT Monitors A interface functions SS7 auxiliary link One SS7 link Base Transceiver Station Auxiliary for Base Transceiver Station Line interface card Spare line interface card 2 Mb RAM of TDPC Main processor Switching network on BSC GPRS Network Service Virtual Connection Nailed Up Connection object identifier GPRS Packet Control Unit identifier Clock generator and distributor Level 2 CCSS7 interface, up till 4 channel at 64 kb/s to/from MSC GPRS Peripheral Packet Control Unit identifier TDPC interface with dual port RAM for LAPD channels GPRS Point to Point Packet Functionality identifier GPRS auxiliary of Point to Point Packet Functionality identifier Power supply to BSC main rack BSC Scanner identifier Switching matrix at 16 kb Switching matrix at 64 kb Sync generator External sync generator Telephone processor It identifies the whole network element TRAU from the equipment point of view. MPCC extended bus

class SBS_MPCCDISK: DISK class TRANSCEIVER: TRX TRXA class LAPDLINK: LPDL
A30808-X3247-K240-3-7619

20/40 Mb hard disk located on MPCC

Radio base station transceiver. It individualises the TRX connected to a BSC with an absolute numbering within the BSC itself.

Logical LAPD protocol link between BSC and BTS-TRAU


587

Outputs OML:BSC

Base Station Controller

OBJECT DESCRIPTION ============================================================================= LPDLM LPDLR LPDLS class CHANNEL: CHAN CHANA Class SBS_TRANSCODER: TRAU Class SBS_BTSSITEMANAGER: BTSM class SBS_OMLINK: LKOM OMAL CBCL X25A X25D TRACE class SBS_PCMCIRCUIT: PCMA PCMB PCML PCMG PCMS PCMT class SBS_TSLA: TSLA TSLT Time slot on A interface Auxiliary for TSLA PCM link on A interface, to/from MSC PCM link on Abis interface, to/from BTS Auxiliary for PCMS or PCMB PCM link on G interface, to/from PPCU PCM link on Asub interface, to/from TRAU Auxiliary for PCMA X.25 auxiliary OM link Protocol X.25 OMC link located on IXLT Cell Broadcast Center link X.25 A Interface X.25 Dedicated Line INSI Tracing is the tracing of subscribers activities when specific events occur within the PLMN. Functionality that controls one or more BTSs located at the same site. It performs the O&M functions common to all transceiver. Transcoder connected between BSC and MSC. Traffic or signalling channel It is an auxiliary mnemonic for the CHANNEL: it uses the number of transceiver as absolute number. Logical link used by the BTSE to communicate with the BSC for O&M purposes. Logical link used by a TRX to communicate with the BSC for radio purposes. Logical link used by the TRAU to communicate with the BSC for O&M purposes.

588

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Annex B

ORIGINATORS list
=================================================================================== NO_ORIGINATOR 0

A30808-X3247-K240-3-7619

589

Outputs OML:BSC

Base Station Controller

OPERATING SYSTEM AREA


MOSFSIO0 MOSFSIO1 MOSFSIO2 MOSFSSC10 MOSFSIODF MOSFSIODD MOSFSIOMP MOSSDCFFS MOSSDNDDL0 MOSSDNDDL1 MOSSDNSBL MOSSDNSTL MOSSDNSBC MOSSDNSTC MOSSDFSMS MOSSDFSRS MOSSDFSCS MOSSDFSDS MOSSDFSMH MOSSDFSMF MOSSDFSUD MOSININSI MOSICCPMT MOSICCPRT MOSICCPST MOSICCPTT MOSICELWR MOSICILEM MOSICILLS MOSICILPH MOSICIOIT MOSICIOOT MOSICIOIO MOSICIOPO MOSICIOPI MOSICILPD MOSICILSH MOSICLFUP MOSICUTBM MOSICUTMT MOSICUSSC MOSICIOIR MOSICCLWR MOSCKTDNS MOSKNMSEH MOSKNMSMS MSDLSLTPI MSDLSLTPL
590

1 2 3 4 5 6 7 122 124 125 126 127 128 129 130 131 132 133 134 135 136 207 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 400 410 411 500 501
A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

MSDLSLTPP MSDLSLTPT MSDLSXCCT MSDSMCTMA MSDSM MSDBASDL MSDSMFWUP MOSIWROMA MOSIWROCO MOSIWRORE MOSIWROSP MOSIWROHE MOSIWMEMA MOSIWMEMI MOSIWMEST MOSIWMEAL MOSIWMETE MOSIWMEME MSDBACTDA MSDBACTMT MSDBACTMA MSDBACTIA MSDBACTPA MSDBACTTA MSDBAFPBU MSDBAIFCA MSDBAIFID MSDBALFAA MSDBACTUA MSDRIBSDH MSDRIBSHC MSDRIBSHF MSDRIBSHT MSDRIBSMA MSDRIBSIU MSDRIBSNU MRTEPSALL MPSOSCALL MPSOSSTMOD MOSGSUTFH TOSSDATPL TSDLSXCCT TOSININSI TOSICIOWD TOSICDMCD TOSICIOIT TOSICIOOT

502 503 504 505 506 507 508 510 511 512 513 514 515 516 517 518 519 520 600 601 603 604 605 606 607 608 609 610 611 620 621 622 623 624 625 626 640 641 642 650 700 750 800 810 811 812 813
591

A30808-X3247-K240-3-7619

Outputs OML:BSC

Base Station Controller

TOSICDMID TOSICCPRT TOSICCPST TOSICCPTT TOSICCPMT TOSICIOIR TOSICIOMM TOSKNMSMS TOSKNMSEH UOSKNMSEH UOSICIOIT UOSICIOOT XOSICUTBM XOSICUTMT XOSICIOPT YOSICIOIT YOSICIOOT YOSKNMSEH NOSICIOIT NOSICIOOT NOSKNMSEH

814 815 816 817 818 819 820 900 901 950 951 952 970 971 972 980 981 982 990 991 992

592

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

DATA BASE AREA


MDATABASE MDBCADHDE MDBCATDTB MDBCASRBK CDBMDBFH CDBMDHSA TDATABASE UDATABASE 2000 2001 2002 2003 2100 2222 2600 2600

A30808-X3247-K240-3-7619

593

Outputs OML:BSC

Base Station Controller

STATUS MANAGER AREA


MSMARECCO MSMARECIN MSMARECTH MSMAREPDE MSMAREPCO MSMAREPHA MSMSHADPA MSMSHADSA MSMSHHDHQ MSMSHHDHT MSMSHISPI MSMSHPIRM MSMSHPICE MSMSHPIHT MSMSHPCCC MSMSHPCCD MSMSHPCHC MSMSHPCPI MSMSHPCSO MSMGSSMFU MSMGSASAA MSMGSASSA MSMGSHRDE MSMGSHRIH MSMGSHRIN TSMARECCO TSMARECIN TSMARECTH TSMGSSMFU USMARECCO USMARECIN USMARECTH PSMARECCO XSMARECCO 3000 3001 3002 3010 3011 3012 3100 3101 3110 3111 3120 3130 3131 3132 3140 3141 3142 3143 3144 3200 3201 3202 3203 3204 3205 3500 3501 3502 3600 3700 3701 3702 3750 3800

594

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

DEVICE HANDLER AREA


MDHACENIN MDHACENSA MDHACPHCJ MDHACPHPF MDHACPHIN MDHDLDDFR0 MDHDLDDFR1 MDHDLDCGP0 MDHNWABAF MDHNWDCHN MDHNWDCSC MDHNWDCUF MDHNWININ MDHNWDCAL MDHNWDCDE MDHNWDCSS MDHNWDCSY MDHNWDCEP MDHUBDDCR MDHPLDDCR MDHPLSHSM MDHPLSHHS MDHSNDDCR MDH16DDCR MDH40IOSC MDH40MTPA MDHBFBTSA MDHBCDCDE MDHBCDCGI MDHBCDCMS MDHBCABHA MDHLCDCDE MDHLCDCSM MDHLCUTSF MDHLCUTGE MDHLCSASC MDHLIIMDI MDHLCININ MDHLCDCIR MDHIXDCSA MDHIXDCMC MDHIXABGA 4000 4001 4002 4003 4004 4100 4101 4102 4200 4201 4202 4203 4204 4205 4206 4207 4208 4209 4220 4230 4231 4232 4240 4250 4305 4306 4350 4351 4352 4353 4354 4400 4401 4402 4403 4404 4405 4406 4407 4450 4451 4452
595

A30808-X3247-K240-3-7619

Outputs OML:BSC

Base Station Controller

MDHIXININ MDHIXDDSW MDHIXDCUF MDHIXDDDR MDHIXDCSM MDHXXDCCH MDHXXDCDE MDHXXDCEH MDHXXDCSA MDHXXDCSM MDHXXDCTH MDHXXDDDI MDHXXDDHD MDHXXGSUT MDHXXININ MDHXXDCBR MDHXXLUCH MDHXXLUDE MDHXXLUEH MDHXXLUSA MDHXXLUSM MDHXXLUTH MDHXXDDLU MDHXXLUUT MDHXXLUIN MDHPRDCDE MDHPRDCMC MDHPRDCSD MDHPRDCUT MDHPRDCSM MDHPRININ MDHPRDCSA MDHPRDDM2 MDHPRDDNH MDHPRDCHL TDHBFCFMN TDHBFDCDB TDHBFDCDE TDHBFDCL3 TDHBFDCMC TDHBFDCMS TDHBFDCSM TDHBFINIT TDHTRDAUP TDHTRDCDE TDHTRDCMC TDHTRDCSM TDHTRDCMS TDHTRINIT TDHTRSASC TDHTRDCDB TDHTRDCL3

4453 4454 4455 4456 4457 4500 4501 4502 4503 4504 4505 4506 4507 4508 4509 4510 4511 4512 4513 4514 4515 4516 4517 4518 4519 4600 4601 4602 4603 4604 4605 4606 4607 4608 4609 4700 4701 4702 4703 4704 4705 4706 4707 4750 4751 4752 4753 4754 4755 4756 4757 4758

596

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

TDHLPINPR TDHLPSAPR TDHLPDCEN TDHLPSASC TDHPRDCSV TDHPRDDNN TDHPRDCHL TDHGPCCIN TDHGPDCDE TDHGPDCMC TDHGPIHGB TDHGPIHSM TDHGPIHL3 UDHPCMNEN UDHPCMNIN UDHPDBUDA UDHPDCNSE UDHPDDAPU UDHPDDARD UDHPDDCMA UDHPDDRAM UDHPDDVDR UDHPDEXHN UDHPDFTDT NDHPDDCMA NDHPDFTDT NDHPDEXHN YDHPDDCMA YDHPDFTDT YDHPDEXHN IXLT_SW

4800 4801 4802 4803 4900 4901 4902 4950 4951 4952 4953 4954 4955 4960 4961 4962 4963 4964 4965 4966 4967 4968 4969 4970 4980 4981 4982 4990 4991 4992 11000

A30808-X3247-K240-3-7619

597

Outputs OML:BSC

Base Station Controller

PERFORM MEASUREMENT AREA


CPM_MPCC_ORIGINATOR CPM_IMSI_ORIGINATOR CPM_CTR_ORIGINATOR CPM_PCUC_ORIGINATOR CPM_TDPC_ORIGINATOR 5000 5001 5002 5100 5500

598

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

LEVEL 3 RADIO AREA


TL3N7SCOC050 TL3N7SCOC060 TL3N7SCLC010 TL3N7SCOC040 TL3N7SCOC030 TL3N7SCOC020 TL3N7SCOC010 TL3N7SCRC010 TL3N7SCPI030 TL3N7SCPI020 TL3N7SCPI010 TL3N7LTST1 TL3N7UTIH1 TL3N7LMAC2 TL3N7LTST2 TL3N7HMDD1 TL3N7LTST3 TL3N7DIMU1 TL3N7DIST1 TL3N7UTEH1 TL3N7UTOH1 TL3N7HMRT1 TL3N7LMAC3 TL3N7LMAC4 TL3N7LMAC5 TL3N7LMAC1 TL3N7TMLA1 TL3N7TMLA2 TL3N7TMSR1 TL3N7TMSR2 TL3N7TMSR3 TL3N7TMCB1 TL3N7TMCB2 TL3N7TMCB3 TL3N7TMCB4 TL3N7TMCB5 TL3N7TMCO1 TL3N7TMCO2 TL3N7TMCO3 TL3N7TMCO4 TL3N7TMCO5 TL3N7TMCO6 TL3N7TMCO7 TL3N7TMCO8 TL3N7UTOS1 TL3N7SCMG010 TL3N7UTER1 TL3N7GEMG1 TL3N7GEMG2 TL3N7GEMG3 TL3N7GEMR1 TL3N7GEGS1 TL3N7UTAUDIT TL3N7TMFC1 7000 7001 7002 7003 7004 7005 7006 7007 7008 7009 7010 7011 7012 7013 7014 7015 7016 7017 7018 7019 7020 7021 7022 7023 7024 7025 7026 7027 7028 7029 7030 7031 7032 7033 7034 7035 7036 7037 7038 7039 7040 7041 7042 7043 7044 7045 7046 7047 7048 7049 7050 7051 7052 7053
599

A30808-X3247-K240-3-7619

Outputs OML:BSC

Base Station Controller

TL3N7GESG1 TL3N7GESG2 TL3N7GESG3 TL3N7GESG4 TL3N7GESG5 TL3N7LMLC1 TL3N7LMLC2 TL3RDALL UPKINRMMRMD UPKINOMMGMD UPKINGBMGBD UPKINABMABD UPKPMUTBUTC UPKPMUTBUTM UPKPMDTBDTC UPKPMDTBDTM UPKTSPRMPCH UPKTSPRMPPM UPKTSPRMPFR UPKTSABBPDS UPKTSABBTBS UPKUTBMBUPR UPKUTBMBBVM UPKUTBMBGPG UPKUTBMBLLM UPKUTBMBLLR UPKUTBMBGOV UPKUTGEMGER UPKUTTGBTGM UPKUTTGBTBM UPKGBICOH UPKGBICSIGIH UPKGBICDATIH UPKTDPCRMIH UPKTDPCOMIH UPKTDPCOH UPKABICIH TL3SCELL TL3AUDIT TL3RTRANFAIL TL3CIPH TL3GPRS TFSEDMSG UFSEDMSG

7054 7055 7056 7057 7058 7059 7060 7100 7200, 8200 7201, 8201 7202, 8202 7203, 8203 7204, 8204 7205, 8205 7206, 8206 7207, 8207 7208, 8208 7209, 8209 7210, 8210 7211, 8211 7212, 8212 7213, 8213 7214, 8214 7215, 8215 7216, 8216 7217, 8217 7218, 8218 7219, 8219 7220, 8220 7221, 8221 7222, 8222 7223, 8223 7224, 8224 7225, 8225 7226, 8226 7227, 8227 7228, 8228 7777 7999 8100 8101 8102 8888 8889

600

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

NETWORK CONTROLLER AREA


MNCPCMHIP MNCPCDHDU MNCANMHIA MNCANDHPL MNCANDHSL MNCANDHOL MNCPCMHCM 8000 8001 8002 8003 8004 8005 8006

A30808-X3247-K240-3-7619

601

Outputs OML:BSC

Base Station Controller

DIAGNOSTIC MANAGER AREA


MDGDMPIPR MDGDMDAPR MDGDMOUPR MDGDMPEPR MDGDMPIIR TDGDMPEPR 9000 9001 9002 9003 9004 9500

602

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

AGENT MANAGER AREA


XQ3LS MQ3US MFTIH MFTRS MBACW MBAMW MBAMF MBAMA MBAAW MQ3CB 9000 10100 10101 10102 10103 10104 10105 10106 10107 10108

A30808-X3247-K240-3-7619

603

Outputs OML:BSC

Base Station Controller

Annex C

File identifiers for MDATABASE originator: DBCACPAC_FILE DBCACPCP_FILE DBCACPBB_FILE DBCACPBC_FILE DBCACPBI_FILE DBCACPBO_FILE DBCACPBT_FILE DBCACPBM_FILE DBCACPFH_FILE DBCACPHP_FILE DBCACPLM_FILE DBCACPLR_FILE DBCACPLS_FILE DBCACPM2_FILE DBCACPM3_FILE DBCACPOP_FILE DBCACPPC_FILE DBCACPMA_FILE DBCACPMB_FILE DBCACPMS_FILE DBCACPRD_FILE DBCACPSC_FILE DBCACPS7_FILE DBCACPTC_FILE DBCACPTR_FILE DBCACPTX_FILE DBCACPEA_FILE DBCACPLA_FILE DBCACPHC_FILE DBCACPHO_FILE DBCACPPM_FILE DBCACPSP_FILE DBCACPSM_FILE DBCACPUT_FILE DBCAECEC_FILE DBCAECRS_FILE DBCAECTX_FILE DBCASRBK_FILE DBCASRAU_FILE DBCASRCH_FILE DBCAIHIN_FILE DBCATDCT_FILE DBCATDGT_FILE DBCATDTD_FILE DBCATDLP_FILE DBCATDTR_FILE DBCATDUT_FILE DBCAUTDU_FILE DBCAUTFC_FILE DBCAUTPH_FILE
604

0x00 0x01 0x02 0x03 0x04 0x05 0x06 0x07 0x08 0x09 0x0A 0x0B 0x0C 0x0D 0x0E 0x0F 0x10 0x11 0x12 0x13 0x14 0x15 0x16 0X32 0x17 0x18 0x19 0x1A 0x1B 0x1C 0x1D 0x1E 0x1F 0X31 0x20 0x21 0x22 0x23 0x24 0x25 0x26 0x27 0x28 0x29 0x2A 0x2B 0x2C 0x2D 0x2E 0x2F
A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

DBCALMLM_FILE DBCACPUT_FILE DBCACPTC_FILE DBCACPNC_FILE DBCACPFR_FILE DBCACPNS_FILE DBCACPCU_FILE DBCACPMG_FILE DBCACPKF_FILE DBCACPML_FILE DBCACPXA_FILE DBCACPXD_FILE DBCACPCL_FILE DBCACPSE_FILE DBCACPTS_FILE DBCACPTF_FILE DBCACPCT_FILE DBCACPLD_FILE DBCACPDS_FILE DBCACPER_FILE DBCACPPD_FILE DBCACPSA_FILE DBCASCBS_FILE DBCASCBM_FILE DBCASCBT_FILE DBCASCIH_FILE DBCASOHO_FILE DBCASOHN_FILE DBCASCBE_FILE DBCASCCX_FILE DBCASCCH_FILE DBCASCGS_FILE DBCASCS7_FILE DBCASCTX_FILE DBCAUTSC_FILE

0x30 0x31 0x32 0x33 0x34 0x35 0x36 0x37 0x38 0x39 0x40 0x41 0x42 0x43 0x44 0x45 0x46 0x47 0x48 0x49 0x4A 0x4B 0x4C 0x4D 0x4E 0x4F 0x50 0x51 0x52 0x53 0x54 0x55 0x56 0x57 0x58

A30808-X3247-K240-3-7619

605

Outputs OML:BSC

Base Station Controller

Annex D
1 Translation table for the 'process Identifier' field in Level 3 Radio error messages

Code 0x00 0x01 0x02 0x03 0x04 0x05 0x06 0x07 0x08 0x09 0x0a 0x0b 0x0c 0x0d 0x0e 0x0f 0x10 0x11 0x12 0x13 0x14 0x15 0x16 0x17 0x18 0x19 0x1a 0x1b 0x1c 0x1d 0x1e 0x1f 0x20 0x21 0x22 0x23 0x24 0x25 0x26 0x27 0x28 0x29 0x2a 0x2b 0x2c 0x2d 0x2e 0x2f
606

Process ITMxxx ITFxxx ITCxxx ICSxxx VBSxxx UTFxxx MUTxxx SMSxxx GAUxxx GIMxxx GITxxx GUTxxx TCHxxx PRMxxx RMNxxx RSRxxx RMRxxx TODxxx TOTxxx COTxxx BLKxxx GBKxxx FRRxxx HOExxx OVLxxx PGGxxx RCPxxx RRQxxx RESxxx SIFxxx CVLxxx TVLxxx POVxxx PBKxxx BBKxxx TRFxxx SRTxxx MISxxx PRExxx ERHxxx PRBxxx LCSxxx LCDxxx GLCxxx LPDxxx SCDxxx OMDxxx GCDxxx

Function Immediate Assignment Father Immediate Assignment Son External Incoming Handover Father External Incoming Handover Son Voice Broadcast Service User process Multislot procedures Short Message GPRS Audit Handler GPRS Initiate Transaction Manager GPRS Initiate Transaction GPRS User Transaction TCH Management Packet Resource Manager Resource Manager Resource Reallocator Resource Manager Recovery Trace Object Device Handler Trace Object Tracer Cell traffic recording Block Handler Circuit Group Handler Frequency Redefinition Handover Cand. Enquire Overload Handler Paging Handler Reset Circuit Resource Request Reset System Info Cell Overload Handler TRX Overload Handler PCU Overload Handler PCU O&M Block BVCI O&M Block Traffic Threshold Manager Suspend/Resume Interference Level band Handler Configuratore HOST LV3 Error Handler Probe (GSM Tester) Location Services Location Services Distributor GPRS Load Control LAPD Distributor SCCP Distributor O&M Distributor GPRS Call Handling Distributor
A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Code 0x30 0x31 0x32 0x33 0x34 0x35 0x36 0x37 0x38 0x39 0x3a 0x3b 0x3c 0x3d 0x3e 0x3f 0x40 0x41 0x42 0x43 0x44 0x45 0x46 0x47 0x48 0x49 0x4a 0x50 0x63 0x6d 0x6e 0x74 2

Process GMDxxx CBPxxx CBAxxx CBBxxx CBFxxx ERCxxx HMDxxx HMRxxx MDSxxx IDSxxx TSTxxx SACxxx LSCxxx LACxxx TSRxxx COCxxx CBCxxx TFCxxx MGNxxx MRCxxx MGSxxx MSGxxx SPIxxx SRCxxx SCLxxx SCOxxx SMGxxx

Function GPRS O&M Distributor Cell Broadcast Process Cell Broadcast Agent Cell Broadcast Scheduling Process Cell Broadcast Failure Handler MTP Error Handler Distribution/Discriminator Handle msg Routing Traffic MSU Distributor IMU Distributor Linkset Control Link Activity Control Linkset Control Link Available Control Signalling Routing Control Changeover Control Changeback Control Signalling Traffic Flow MSU Generator for Traffic Simulator MSU_TEST_UP Receiver MSU Generator for Network Management SCCP Test Generator SCCP Process Input SCCP Routing Control Process Connectionless Process Connection Oriented SCCP Management Process Timeout controller for finite state machine Finite state machine Operating System

OUHxxx OSHxxx INHxxx

Output handler Status Manager Handler Input Handler

Translation table for 'Code Message' and 'EDOS Signal' fields in Level 3 Radio error messages CONST MSG_ASSREQ MSG_ASSCOM8 MSG_ASSFLT8 MSG_VSETUP MSG_VSETUPACK MSG_VSETUPREF MSG_VASSREQ MSG_HNDRQS MSG_HNDRQT MSG_HNREQACK MSG_HNDCMD8 MSG_HNDCOM8 MSG_HNDFLT8 Value 0x01 0x02 0x03 0x04 0x05 0x06 0x07 0x10 0x11 0x12 0x13 0x14 0x16 Meaning Assignment Request Assignment Complete Assignment Failure VGCS/VBS Setup VGCS/VBS Setup Ack. VGCS/VBS Setup Refused VGCS/VBS Assignment Request Handover Request Handover Required Handover Request ACK Handover Command Handover Complete Handover Failure Recommand. GSM 8.08 GSM 8.08 GSM 8.08 GSM 8.08 GSM 8.08 GSM 8.08 GSM 8.08 GSM 8.08 GSM 8.08 GSM 8.08 GSM 8.08 GSM 8.08 GSM 8.08
607

A30808-X3247-K240-3-7619

Outputs OML:BSC

Base Station Controller

CONST MSG_HNDPRF MSG_HNDCNENQ MSG_HNDCNRES MSG_HNDREQRE MSG_HNDDET MSG_VASSRES MSG_VASSFLT MSG_VQUEIND MSG_UPRQ MSG_CLRCMD MSG_CLRCOM MSG_CLRREQ MSG_SAPIREJ MSG_CONFUS MSG_UPRQACK MSG_RES MSG_RESACK MSG_OVL MSG_TRCINV MSG_RCP MSG_RCPACK MSG_MSC_INVOKE_TRAC MSG_BSS_INVOKE_TRAC MSG_BLK MSG_BLKACK MSG_UNB MSG_UNBACK MSG_GBLK MSG_GBLKACK MSG_GUNB MSG_GUNBACK MSG_UNEQUIP MSG_UPRQCONF MSG_UPRELIND MSG_UPRJCMD MSG_UPRELCMD MSG_UPSEIZED MSG_RESREQ MSG_RESIND MSG_PAG MSG_CIPCMD8 MSG_CLSUPD MSG_CIPCOM8 MSG_QUEIND MSG_LAY3COM MSG_CLSREQ MSG_CIPHREJ MSG_DATREQ MSG_DATIND MSG_ERRIND MSG_ESTREQ MSG_ESTCON MSG_ESTIND MSG_RELREQ
608

Value 0x17 0x18 0x19 0x1a 0x1b 0x1c 0x1d 0x1e 0x1f 0x20 0x21 0x22 0x25 0x26 0x27 0x30 0x31 0x32 0x33 0x34 0x35 0x36 0x37 0x40 0x41 0x42 0x43 0x44 0x45 0x46 0x47 0x48 0x49 0x4a 0x4b 0x4c 0x4d 0x50 0x51 0x52 0x53 0x54 0x55 0x56 0x57 0x58 0x59 0x01 0x02 0x03 0x04 0x05 0x06 0x07

Meaning Handover Performed Handover Cand.Enq Handover Cand.Res Handover Req.Rej. Handover Detect VGCS/VBS Assignment Result VGCS/VBS Assignment Failure Queuing Indication Uplink Request Clear Command Clear Complete Clear Request SAPIn Reject Confusion Uplink Request Ack Reset Reset Acknowledge Overload Trace Invocation Reset Circuit Reset Circuit Ack. MSC Invoke Trace BSS Invoke Trace Block Block Acknowledge Unblock Unblock Acknowledge Circuit Group Block Circuit Group Block Ack Circuit Group Unblock Circuit Group Unblock Ack Unequipped Circuit Uplink Request Confirm Uplink Release Indication Uplink Rejected Command Uplink Release Command Uplink Seized Resource Request Resource Indication Paging Cipher mode Command Classmark Update Cipher mode Complete Queuing Indication Complete Layer3inf. Classmark Request Cipher mode Reject Data Request Data Indication Error Indication Establish Request Establish Confirm Establish Indication Release Request

Recommand. GSM 8.08 GSM 8.08 GSM 8.08 GSM 8.08 GSM 8.08 GSM 8.08 GSM 8.08 GSM 8.08 GSM 8.08 GSM 8.08 GSM 8.08 GSM 8.08 GSM 8.08 GSM 8.08 GSM 8.08 GSM 8.08 GSM 8.08 GSM 8.08 GSM 8.08 GSM 8.08 GSM 8.08 GSM 8.08 GSM 8.08 GSM 8.08 GSM 8.08 GSM 8.08 GSM 8.08 GSM 8.08 GSM 8.08 GSM 8.08 GSM 8.08 GSM 8.08 GSM 8.08 GSM 8.08 GSM 8.08 GSM 8.08 GSM 8.08 GSM 8.08 GSM 8.08 GSM 8.08 GSM 8.08 GSM 8.08 GSM 8.08 GSM 8.08 GSM 8.08 GSM 8.08 GSM 8.08 GSM 8.58 GSM 8.58 GSM 8.58 GSM 8.58 GSM 8.58 GSM 8.58 GSM 8.58
A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

CONST MSG_RELCON MSG_RELIND MSG_UDATREQ MSG_UDATIND MSG_BCCHINF MSG_CCCHLD MSG_CHREQ MSG_DELIND MSG_PAGCMD MSG_IMASSCMD MSG_SMSBCREQ MSG_RFRESIND MSG_SACCH MSG_OVERLD MSG_ERREP MSG_SMSBCCMD MSG_NOTCMD MSG_CHACT MSG_CHACTOK MSG_CHACTKO MSG_CONFLT MSG_DESACCH MSG_ENCCMD MSG_HNDDCTON MSG_MDMODREQ MSG_MDMODOK MSG_MDMODKO MSG_PHCNTREQ MSG_PHCNTCON MSG_RFCHREL MSG_MSPWCNT MSG_BSPWCNT MSG_PRECON MSG_PREMIS MSG_RFCHROK MSG_TALKDET MSG_RFPOWER MSG_HOINTRA MSG_HOINTER MSG_HOFORCED MSG_PREFAREQ MSG_PREFAREA MSG_BTS_STARTTR MSG_BTS_STARTTROK MSG_BTS_STOPTR MSG_TR_MEAS MSG_HOFAILIN MSG_BTS_STOPTROK MSG_UPFREE MSG_UPBUSY MSG_SETSYS10 MSG_MODCONIN

Value 0x08 0x09 0x0a 0x0b 0x11 0x12 0x13 0x14 0x15 0x16 0x17 0x19 0x1a 0x1b 0x1c 0x1d 0x1f 0x21 0x22 0x23 0x24 0x25 0x26 0x27 0x29 0x2a 0x2b 0x2c 0x2d 0x2e 0x2f 0x30 0x31 0x32 0x33 0x35 0x41 0x42 0x43 0x44 0x45 0x46 0x47 0x48 0x49 0x4A 0x4B 0x4C 0x4d 0x4e 0x4f 0x50

Meaning Release Confirm Release Indication Unit Data Request Unit Data Indication BCCH Information CCCH Load Indication Channel Required Delete Indication Paging Command Immediate Ass. Command SMS broadcast Request RF Resource Indication SACCH Filling Overload Error Report SMS Broadcast Command Notification Command Channel Activation Channel Activation OK Channel Activation KO Connection Failure Deactivate SACCH Encryption Command Handover Detection Mode Modify Request Mode Modify OK Mode Modify KO Physical Context Req. Physical Context Con. RF Channel Release MS Power Control BS Power Control Pre-Process Configure Pre-Proc Measurement RF Channel Release OK Talker Detection MS RF Pow. Cap Prop.Abis Intracell HO Cond. Ind. Intercell HO Cond. Ind. Forced HO Request Preferred Area Req. Preferred Area Bts Start trace Bts Start trace ACK Bts Stop trace Trace Measure HO Failure Indication Bts Stop trace ACK Uplink Free (propr.) Uplink Busy (propr.) Set System Info.10 (propr.) Mod.Condition Ind.

Recommand. GSM 8.58 GSM 8.58 GSM 8.58 GSM 8.58 GSM 8.58 GSM 8.58 GSM 8.58 GSM 8.58 GSM 8.58 GSM 8.58 GSM 8.58 GSM 8.58 GSM 8.58 GSM 8.58 GSM 8.58 GSM 8.58 GSM 8.58 GSM 8.58 GSM 8.58 GSM 8.58 GSM 8.58 GSM 8.58 GSM 8.58 GSM 8.58 GSM 8.58 GSM 8.58 GSM 8.58 GSM 8.58 GSM 8.58 GSM 8.58 GSM 8.58 GSM 8.58 GSM 8.58 GSM 8.58 GSM 8.58 GSM 8.58 GSM 8.58 GSM 8.58 GSM 8.58 GSM 8.58 GSM 8.58 GSM 8.58 GSM 8.58 GSM 8.58 GSM 8.58 GSM 8.58 GSM 8.58 GSM 8.58 GSM 8.58 GSM 8.58 GSM 8.58 GSM 8.58

A30808-X3247-K240-3-7619

609

Outputs OML:BSC

Base Station Controller

CONST MSG_SYSINFO10 MSG_SYSINF13 MSG_PRTREL MSG_CHREL MSG_PARELCOM MSG_CHMOD MSG_RRSTATUS MSG_CLASENQ MSG_FREQREF MSG_CLASCHN MSG_CHMODOK MSG_SYSINF2B MSG_SYSINF2T MSG_NOTFACCH MSG_SYSINF5B MSG_SYSINF5T MSG_UPFREE408 MSG_UPREL4 MSG_TALKIND4 MSG_SYSINF1 MSG_SYSINF2 MSG_SYSINF3 MSG_SYSINF4 MSG_SYSINF5 MSG_SYSINF6 MSG_SYSINF7 MSG_SYSINF8 Radio Resource management MSG_PAGREQ1 MSG_PAGREQ2 MSG_PAGREQ3 MSG_PAGRES MSG_HNDFLT4 MSG_ASSCOM4 MSG_UPBUSY408 MSG_HNDCMD4 MSG_HNDCOM4 MSG_PHYINF MSG_ASSCMD MSG_ASSFLT4 MSG_CFGCHCMD MSG_CFGCHACK MSG_CIPCOM4 MSG_CFGCHREJ MSG_CIPCMD4 MSG_IMASSEX MSG_IMASSRE MSG_ADDASS MSG_IMASS

Value 0x00 0x00 0x0a 0x0d 0x0f 0x10 0x12 0x13 0x14 0x16 0x17 0x02 0x03 0x04 0x05 0x06 0x08 0x0e 0x11 0x19 0x1a 0x1b 0x1c 0x1d 0x1e 0x18 0x1f

Meaning System Info. Type 10 - Short Protocol Discriminator System Information 13 Long Protocol Discriminator Partial Release Channel Release Partial Release Comp. Channel Mode Modify RR Status Classmark Enquire Frequency Redefinition Classmark Change Channel Mode Modify OK SystemInformation2bis SystemInformation2ter Notification/FACCH SystemInformation5bis SystemInformation5ter Uplink Free Uplink Release Talker Indication SystemInformation1 SystemInformation2 SystemInformation3 SystemInformation4 SystemInformation5 SystemInformation6 SystemInformation7 SystemInformation8

Recommand. GSM 4.08 GSM 4.08 GSM 4.08 GSM 4.08 GSM 4.08 GSM 4.08 GSM 4.08 GSM 4.08 GSM 4.08 GSM 4.08 GSM 4.08 GSM 4.08 GSM 4.08 GSM 4.08 GSM 4.08 GSM 4.08 GSM 4.08 GSM 4.08 GSM 4.08 GSM 4.08 GSM 4.08 GSM 4.08 GSM 4.08 GSM 4.08 GSM 4.08 GSM 4.08 GSM 4.08

0x21 0x22 0x24 0x27 0x28 0x29 0x2a 0x2b 0x2c 0x2d 0x2e 0x2f 0x30 0x31 0x32 0x33 0x35 0x39 0x3a 0x3b 0x3f

PagingRequesttype1 PagingRequesttype2 PagingRequesttype3 Paging Response Handover Failure Assignment Complete Uplink Busy Handover Command Handover Complete Physical Information Assignment Command Assignment Failure Conf. Change Cmd. Conf. Change Ack. Ciphering mode Complete Conf. Change Rej. Ciphering mode Command Imm. Assign. Extended Imm. Assignment Reject Additional Assignment Immediate Assignment

GSM 4.08 GSM 4.08 GSM 4.08 GSM 4.08 GSM 4.08 GSM 4.08 GSM 4.08 GSM 4.08 GSM 4.08 GSM 4.08 GSM 4.08 GSM 4.08 GSM 4.08 GSM 4.08 GSM 4.08 GSM 4.08 GSM 4.08 GSM 4.08 GSM 4.08 GSM 4.08 GSM 4.08

610

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

CONST Mobility management MSG_IMSIDET0 MSG_IMSIDET1 MSG_LOCUPRQ0 MSG_LOCUPRQ1 MSG_CMSERRQ0 MSG_CMSERRQ1 MSG_CMRSTRQ0 MSG_CMRSTRQ1 MSG_IMMSETUP MSG_SCCPPAU MSG_SCCPRES MSG_DISCREQ MSG_UDATAREQ MSG_CONNIND MSG_CONNCONF MSG_DATAIND MSG_DISCIND MSG_UNITIND MSG_CONNREQ MSG_CONNRES MSG_DATAREQ MSG_RESMEAS MSG_RFDSPPOWER MSG_ATTCH MSG_ATTCHOK MSG_ATTCHKO MSG_INTPAG MSG_TCHRQOK MSG_TCHRQKO MSG_RELCH MSG_RESACT MSG_RRDISCON MSG_ABNOREL MSG_RESEND MSG_CONCONF MSG_INTRES MSG_TRNEND MSG_TRASP MSG_CONUNLK MSG_TERCHRELDON MSG_HNDCOMIN MSG_ASSCOMIN MSG_TSTERCHREL MSG_MATREQ MSG_BLKDONE MSG_UNBDONE MSG_RADCHREL MSG_INADJSP MSG_OMCHREL RESET_RCVD
A30808-X3247-K240-3-7619

Value

Meaning

Recommand.

0x01 0x41 0x08 0x48 0x24 0x64 0x28 0x68 0x31 0xec 0xed 0xee 0xef 0xf0 0xf1 0xf2 0xf3 0xf4 0xf5 0xf6 0xf7 0xfc 0xfe 0xa0 0xa1 0xa2 0xa3 0xa4 0xa5 0xa6 0xa7 0xa8 0xa9 0xaa 0xab 0xac 0xad 0xae 0xaf 0xb1 0xb2 0xb3 0xb0 0xb4 0xb5 0xb6 0xb7 0xb8 0xb9 0xba

IMSI Detach Indication IMSI Detach Indication Location Updating Req. Location Updating Req. CM Service Request CM Service Request CM Reestablishment Req. CM Reestablishment Req. Immediate Setup SCCP Pause SCCP Resume Disconnect Request Unit Data Request Connect Indication Connect Confirm Data Indication Disconnect Indication Unit Data Indication Connect Request Connect Response Data Request Reset Measure MS RF Power capability Channel activat. Channel activ. OK Channel activ. KO Paging Channel request OK Channel request KO Channel release Reset in Progress Disconnect Connection Sccp Abnormal Release ResetTerminat Connection confirm Reset Request Transition terminated Transparent SAPI3 Connessione sbloccata TsTer Release Done Handover Complete Int. Assignment Complete Int. Release matrix Matrix operation Block Done Unblock Done Radio Release Done Inac. Adjc Sig. Point O&M Channel Release Reset Received

GSM 4.08 GSM 4.08 GSM 4.08 GSM 4.08 GSM 4.08 GSM 4.08 GSM 4.08 GSM 4.08 GSM 4.68 Siemens Siemens Siemens Siemens Siemens Siemens Siemens Siemens Siemens Siemens Siemens Siemens Siemens Siemens Internal Internal Internal Internal Internal Internal Internal Internal Internal Internal Internal Internal Internal Internal Internal Internal O&Mint. Internal Internal O&Mint. O&Mint. O&Mint. O&Mint. O&Mint. Internal O&Mint. Internal
611

Outputs OML:BSC

Base Station Controller

CONST MSG_OMSYSIN MSG_HOCNDTRM MSG_RRCONNAB MSG_RRCHREL MSG_EHCHREL MSG_TCHREQ MSG_ATTCHCIP MSG_ABNCONFLT MSG_INTRRCONNAB MSG_SETEHF MSG_OVSYSIN MSG_S7SYSIN MSG_OVPROGR MSG_INTOVL MSG_EDOSTIM MSG_INICHREL MSG_PINGMS MSG_OMTCHIS MSG_OMCHSD MSG_OMFRERED MSG_UNBREQ MSG_ERROR MSG_RETRFAIL MSG_STATEREQ MSG_STATEIND MSG_PCSTATEIND RESCIRC_RCVD Msg for GPRS MSG_PCHREQ MSG_PSI1 MSG_PSI2 MSG_PSI3 MSG_PSI3B MSG_PSI4 MSG_PSI5 MSG_PSI13 MSG_PDCHSET MSG_PCCCHSET MSG_PDCHKO MSG_PDTREAL MSG_PDCHRELO MSG_SYSUPD MSG_PDCHFRR MSG_PDTAUDIT MSG_BVCCRT MSG_BVCDEL MSG_BVCACT MSG_BVCDEACT MSG_BSSREST MSG_GBUNAV
612

Value 0xbb 0xbc 0xbd 0xbe 0xbf 0xc0 0xc1 0xc2 0xc3 0xc4 0xc5 0xc6 0xc7 0xc8 0xc9 0xca 0xcb 0xda 0xdc 0xeb 0xea 0xe9 0xe8 0xe7 0xe6 0xe5 0x9f

Meaning O&M System Information Handover Cand. Term. RR Connection Abort RR Channel Release Error Hand. Chan. Rel. Channel request Attiv. CHAN Chip Internal Conn failure Internal RRCONNAB Set Flag Error Handler Overload System Info SS7FaultSystemInfo Overload in Progress Overload interno TimerEdos GSM Tester Ch. Release Task Init AuditconilMobile O&M TCH returned in Service O&M TCH Shutting Down O&M Frequency Redefin Unblock Request Error message Msg retrasmision Fault Sccp Management Sccp Management Sccp Management Reset Circuit Received

Recommand. O&Mint. Internal O&Mint. Internal O&Mint. Internal Internal Internal Internal Internal Internal Internal Internal Internal Internal Internal Internal O&Mint. O&Mint. O&Mint. O&Mint. Internal Internal Siemens Siemens Siemens Internal

0x00 0x01 0x02 0x03 0x04 0x05 0x06 0x07 0x08 0x09 0x0a 0x0b 0x0c 0x0d 0x0e 0x0f 0x10 0x11 0x12 0x13 0x14 0x15

Channel Request Packet System Information 1 Packet System Information 2 Packet System Information 3 Packet System Information 3 bis Packet System Information 4 Packet System Information 5 Packet System Information 13 PDCH Setup PCCCH Setup PDCH KO PDT Reallocated PDCH Release start from TDPC SYSINFO UPDATE PDT FreqRed PDT Audit BVC Create BVC Delete BVC Activate BVC Deactivate BSS Restart GB Unavailable

TDPC-PCUint. TDPC-PCUint. TDPC-PCUint. TDPC-PCUint. TDPC-PCUint. TDPC-PCUint. TDPC-PCUint. TDPC-PCUint. TDPC-PCUint. TDPC-PCUint. TDPC-PCUint. TDPC-PCUint. TDPC-PCUint. TDPC-PCUint. TDPC-PCUint. TDPC-PCUint. TDPC-PCUint. TDPC-PCUint. TDPC-PCUint. TDPC-PCUint. TDPC-PCUint. TDPC-PCUint.

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

CONST MSG_IMASSG MSG_IMASSDOWNG MSG_IMASSREG MSG_PDCHREL MSG_PDCHREQ MSG_PDCHRELA MSG_PCCCHSET_RESP MSG_PDTAUDITRESP MSG_CSPAG MSG_PSPAG MSG_PCUOVDET MSG_BVCRFAIL MSG_BVCBFAIL MSG_BVCUFAIL MSG_BVCRCOMP MSG_BVCBCOMP MSG_BVCUCOMP MSG_SBVCRREC MSG_SBVCRCOM MSG_BSSRESTAC MSG_BSSRESTNA MSG_GBUNAVAC MSG_BVCRSTR MSG_BVCBSTR MSG_BVCUSTR MSG_BVCDELA MSG_BVCFLCFAIL MSG_BVCRES MSG_BVCINIT MSG_BVCLCK MSG_BVCDISM MSG_BVCDISF MSG_BVCPCUOOS MSG_BVCUNBLK MSG_OMPSI MSG_GPRSAV MSG_GPRSNA MSG_PCUINS MSG_PCUOOS MSG_PDCHREQA MSG_PDCHREQN MSG_PDCHACT MSG_PDCHACTA MSG_PDCHACTN MSG_PCCCHREQ MSG_PCCCHREQA MSG_PCCCHREQN MSG_PCCCHREL MSG_PDCHFOREL MSG_PDCHFORA MSG_PDCHFORN
A30808-X3247-K240-3-7619

Value 0x50 0x51 0x52 0x53 0x54 0x55 0x56 0x57 0x58 0x59 0x5a 0x60 0x61 0x62 0x63 0x64 0x65 0x66 0x67 0x68 0x69 0x6a 0x6b 0x6c 0x6d 0x6e 0x6f 0xa0 0xa1 0xa2 0xa3 0xa4 0xa5 0xa6 0xa7 0xa8 0xa9 0xaa 0xab 0xc0 0xc1 0xc2 0xc3 0xc4 0xc7 0xc8 0xc9 0xca 0xcd 0xce 0xcf

Meaning Immediate Assignement Immediate Assignment Downlink Immediate Assignment Reject PDCH Release start from PCU PDCH Request PDCH Release Ack PCCCH Setup Response PDT Audit Response GPRS Paging PS GPRS Paging CS PCUC Overload Detected BVC Reset Fail BVC Block Fail BVC Unblock Fail BVC Reset Complete BVC Block Complete BVC Unblock Complete SBVC Reset Received SBVC Reset Complete BSS Restart Ack BSS Restart Nack GB Unavailable Ack BVC Reset Start BVC Block Start BVC Unblock Start BVC Delete Ack BVC Flow Control Failed BVC Reset BVC Init BVC Lock BVC Disable for Maintenance BVC Disable for NSVC failure BVC Disable for PCU failure BVC Unblock Packet System Information updated GPRS Available GPRS Not Available PCU In Service PCU out of Service PDCH Request Ack PDCH Request Nack PDCH Activation PDCH Activation Ack PDCH Activation Nack PCCCH Request PCCCH Request Ack PCCCH Request Nack PCCCH Release PDCH Forced Release PDCH Forced Release Ack PDCH Forced Release Nack

Recommand. TDPC-PCUint. TDPC-PCUint. TDPC-PCUint. TDPC-PCUint. TDPC-PCUint. TDPC-PCUint. TDPC-PCUint. TDPC-PCUint. TDPC-PCUint. TDPC-PCUint. TDPC-PCUint. TDPC-PCUint. TDPC-PCUint. TDPC-PCUint. TDPC-PCUint. TDPC-PCUint. TDPC-PCUint. TDPC-PCUint. TDPC-PCUint. TDPC-PCUint. TDPC-PCUint. TDPC-PCUint. TDPC-PCUint. TDPC-PCUint. TDPC-PCUint. TDPC-PCUint. TDPC-PCUint. O&Mint. O&Mint. O&Mint. O&Mint. O&Mint. O&Mint. O&Mint. O&Mint. O&Mint. O&Mint. O&Mint. O&Mint. Internal Internal Internal Internal Internal Internal Internal Internal Internal Internal Internal Internal
613

Outputs OML:BSC

Base Station Controller

CONST MSG_GBUP MSG_GBDOWN MSG_EHMSG

Value 0xd2 0xd3 0xf0

Meaning GB Interface available GB Interface unavailable Task init or abaort occurs

Recommand. Internal Internal Internal

Msg for SCCP CONNECTION_REQUEST CONNECTION_CONFIRM CONNECTION_REFUSED RELEASED RELEASE_COMPLETE DATA_FORM DATA_FORM2 DATA_ACKNNOLEDGEMENT UNITDATA UNITDATA_SERVICE EXPECTED_DATA EXPECTED_DATA_ACKN RESET_REQUEST RESET_CONFIRM PROTOCOL_DATAUNIT_ERROR INACTIVITY_TEST rfailure 3 0x01 0x02 0x03 0x04 0x05 0x06 0x07 0x08 0x09 0x0a 0x0b 0x0c 0x0d 0x0e 0x0f 0x10 0xba

Translation table for 'Code Message' as timer expired in the 'MESSAGE OUT OF SEQUENCE" error when the originator is the Timer Controller of the finite state machine T1 T2 T3 T4 T7 T8 T10 T13 T16 T17 T18 T19 T20 TFHO T11 TQHO T3101 T3105 T3109 1 2 3 4 7 8 10 13 16 17 18 19 20 99 11 21 1 3 5 Time to receive blocking ack message Reset guard period at the MSC Resource Indication periodicity Time to return of reset ack message Handover Required periodicity Time to receive handover inform. Time to return of Ass. Com. or Ass. Failure from MS Reset guard period at the BSC Time to return of Res Ack to MSC BSS Overload time BSS Overload time Time of Res Circ ack reception Time to receive a Cir. Group Block - Unblock Ack Forced HO timer - Proprietary Timer for queuing in Handover procedure Timer for queuing in Assignment request procedure Time to allocate channel on IMMEDIATE ASS. Time to repeat PHYSICAL INF. during HO Time to permit a correctly release of the channel in case of loss of
A30808-X3247-K240-3-7619

614

Base Station Controller

Outputs OML:BSC

T3111 TBL TUN TB TU T21 T20_OMINT T20_EQFLT TPER tconn_est tias tiar trel tguard tsbs twc_user tint MTP_TIMER_T17 MTP_TIMER_T1 MTP_TIMER_STMREADY MTP_TIMER_T_GEN MTP_TIMER_T12 MTP_TIMER_T13 MTP_TIMER_T14 MTP_TIMER_T22 MTP_TIMER_T23 MTP_TIMER_T24 MTP_TIMER_T3 MTP_TIMER_T4 MTP_TIMER_T5 MTP_TIMER_BSNT MTP_TIMER_T2 MTP_TIMER_FSNC MTP_TIMER_RETR_COMPL TBVCRST TBVCBLK TBVCUBLK Internal Timer

6 21 22 23 24 21 22 23 23 0xa0 0xa1 0xa2 0xa3 0xa4 0xa5 0xa6 0xa7 0x44 0x45 0x46 0x4a 0x5f 0x60 0x61 0x62 0x63 0x64 0x74 0x75 0x76 0x77 0x7c 0x7d 0x82 0x01 0x02 0x03 0x01.. ..0xff

communication Time to delay channel deactivation Timer for Block procedure - proprietary Timer for Unblock procedure - proprietary Timer for Cir. Group Block - proprietary Timer for Cir. Group UnBlock - proprietary Timer for Cir. Group unblock - proprietary Timer for Cir. Group Block with cause O&M INTERVENTION Timer for Cir. Group Block with cause EQUIPMENT FAILURE Time of periodicity in RESOURCE REQUEST - proprietary Waiting for Connection Confirm message Inactivity test sent timer Inactivity test receive timer Wait for release complete message Wait to resume normal procedures for the temporary connection sections during restart procedure Delay for state information Manufacture dependent timer - proprietary Wait to report abnormal release to maintenance function Delay to avoid oscillation of the initial alignment Delay to avoid out-of-sequence of messages in CO Wait of stm_ready Delay for MSU generator Wait for uninhibit acknowledgement Wait to force uninhibit Wait for inhibit acknowledgement Local inhibit test timer Remote inhibit test timer Remote processor outage Diversion delay controlled by a timer Wait for CB acknowledgement first attempt Wait for CB acknowledgement second attempt TCOC wait for L2 response Wait for CO acknowledgement Wait for retrieval start Wait for retrieval complete Timer for wait the BVC Reset Complete (equal to T2 of PCU) Timer for wait the BVC Block Complete (equal to T1 of PCU) Timer for wait the BVC Unblock Complete (equal to T1 of PCU) Time to receive the internal ack or nack message

Translation table for the Originator and 'Process Sending Message' field in UPK error messages
615

A30808-X3247-K240-3-7619

Outputs OML:BSC

Base Station Controller

Originator Code 7200/8200 7201/8201 7202/8202 7203/8203 7204/8204 7205/8205 7206/8206 7207/8207 7208/8208 7209/8209 7210/8210 7211/8211 7212/8212 7213/8213 7214/8214 7215/8215 7216/8216 7217/8217 7218/8218 7219/8219 7220/8220 7221/8221 7222/8222 7223/8223 7224/8224 7225/8225 7226/8226 7227/8227 7228/8228

Process

Code in Process Sending Message field 0x00 0x01 0x02 0x03 0x04 0x05 0x06 0x07 0x08 0x09 0x0a 0x0b 0x0c 0x0d 0x0e 0x0f 0x10 0x11 0x12 0x13 0x14 0x15 0x64 0x67 0x68 0x69 0x6a 0x65 0x6b 0x50 0x3c

Process Meaning

PKINRMMRMD PKINOMMGMD PKINGBMGBD PKINABMABD PKPMUTBUTC PKPMUTBUTM PKPMDTBDTC PKPMDTBDTM PKTSPRMPCH PKTSPRMPPM PKTSPRMPFR PKTSABBPDS PKTSABBTBS PKUTBMBUPR PKUTBMBBVM PKUTBMBGPG PKUTBMBLLM PKUTBMBLLM PKUTBMBGOV PKUTGEMGER PKUTTGBTGM PKUTTGBTBM PKGBICOH PKGBICSIGIH PKGBICDATIH PKTDPCRMIH PKTDPCOMIH PKTDPCOH PKABICIH

GPRS Resource Management Message Distributor GPRS O&M Message Distributor GbIC Message Distributor AbIC Message Distributor Uplink TBF Instance Choosing Uplink TBF Management Downlink TBF Instance Choosing Downlink TBF Management PDTCH Management PPCU/PPXU Management Packet Frequency Redefinition PDCH Scheduler TRX Scheduler UPK Restart BVC Management GPRS Paging LLC Management LLC Routing GPRS Overload Management GPRS Error Management Utilities + Test Generator Messages Utilities for GPRS testing GbIC Output Handler GbIC Signalling Input Handler GbIC Data Input Handler TDPC Radio Resource Management Input Handler TDPC O&M Input Handler TDPC Output Handler AbIC Input Handler Edos Timer Handler (on PCUX) Edos Timer Handler (on PCUC)

Translation table for the Procedure Module Originator field in UPK error messages

Originator Code 0x01 0x02 0x03 0x04 0x05 0x06 0x07 0x08 0x09 0x0a
616

Procedure Module PKPRC PKINPRC PKPMPRC PKTSPRC PKUTPRC PKINRMMPRC PKINOMMPRC PKINGBMPRC PKINABMPRC PKINRMMRMDPRC

Module with Procedures common to: Packet Functional Area PK Interface Subsystem PK Packet Mgmt. Subsystem PK Time Scheduler Subsystem PK Utilities Subsystem PKIN Radio Resource Management Message Block PKIN O&M Message Block PKIN GbIC Message Block PKIN AbIC Message Block PKINRMM Distributor Process
A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Originator Code 0x0b 0x0c 0x0d 0x0e 0x0f 0x10 0x11 0x12 0x13 0x14 0x15 0x16 0x17 0x18 0x19 0x1a 0x1b 0x1c 0x1d 0x1e 0x1f 0x20 0x21 0x22 0x23 0x24 0x25 0x26 0x32 0x33

Procedure Module PKINOMMGMDPRC PKINGBMGBDPRC PKINABMABDPRC PKPMUTBPRC PKPMDTBPRC PKPMUTBUTCPRC PKPMUTBUTMPRC PKPMDTBDTCPRC PKPMDTBDTMPRC PKTSPRMPRC PKTSABBPRC PKTSPRMPCHPRC PKTSPRMPPMPRC PKTSPRMPFRPRC PKTSABBPDSPRC PKTSABBTBSPRC PKUTBMBPRC PKUTGEMPRC PKUTGBMPRC PKUTBMBUPRPRC PKUTBMBBVMPRC PKUTBMBGPGPRC PKUTBMBLLMPRC PKUTBMBLLRPRC PKUTBMBGOVPRC PKUTGEMGERPRC PKUTTGBTGMPRC PKUTTGBTBMPRC PKPRCE PKPRC3

Module with Procedures common to: PKINOMM Distributor Process PKINGBM Distributor Process PKINABM Distributor Process PKPM Uplink TBF Block PKPM Downlink TBF Block PKPMUTB Uplink TBF Choosing Process PKPMUTB Uplink TBF Management Process PKPMDTB Downlink TBF Choosing Process PKPMDTB Downlink TBF Management Process PKTS Resource Management Block PKTS AbIC Interface Management Block PKTSPRM PDTCH Management Process PKTSPRM PCU Management Process PKTSPRM Packet Frequency Redefinition Process PKTSABB PDCH Scheduler Process PKTSABB TBF Scheduler Process PKUT BSSGP Management Block PKUT GPRS Error Management Block PKUT GPRS Test Generator and Utilities Block PKUTBMB UPK Restart Process PKUTBMB BVC management Process PKUTBMB GPRS Paging Process PKUTBMB LLC Management Process PKUTBMB LLC Routing Process PKUTBMB GPRS Overload Process PKUTGEM GPRS Error Management Process PKUTTGB Utilities + Test Generator Process PKUTTGB Utilities for GPRS Testing Process Packet Functional Area Packet Functional Area

Translation table for 'Code Message' and 'EDOS Signal Code' fields in UPK error messages CONST MSG_CHANNEL_REQUEST MSG_Packet_System_Information_1 MSG_Packet_System_Information_2 MSG_Packet_System_Information_3 MSG_Packet_System_Information_3_bis MSG_Packet_System_Information_4 MSG_Packet_System_Information_5 MSG_Packet_System_Information_13 MSG_PDCH_Setup MSG_PCCCH_Setup MSG_PDCH_KO MSG_PDT_Reallocated MSG_PDCH_Rel MSG_PSI_Update MSG_PDT_Audit Value 0x00 0x01 0x02 0x03 0x04 0x05 0x06 0x07 0x08 0x09 0x0a 0x0b 0x0c 0x0d 0x0f

A30808-X3247-K240-3-7619

617

Outputs OML:BSC

Base Station Controller

CONST MSG_BVC_Create MSG_BVC_Delete MSG_BVC_Activate MSG_BVC_Deactivate MSG_BSS_Restart MSG_BSS_Gb_Unavailable MSG_BVC_Management_Start MSG_BVC_Management_Stop MSG_BVC_Release MSG_FLOW_CONTROL_Update MSG_BVC_STATUS_BLOCKED MSG_BVC_STATUS_UNK MSG_BVC_Block_Start MSG_GPRS_PreemptionReq MSG_GPRS_SUSPEND_REQ MSG_PDCH_FoRel MSG_GPRS_RESUME_REQ MSG_DL_UNITDATA MSG_HV_STATE MSG_PAGING_PS MSG_PAGING_CS MSG_FLUSH_LL MSG_FLOW_CONTROL_BVC_ACK MSG_BVC_BLOCK_ACK MSG_BVC_UNBLOCK_ACK MSG_BVC_RESET MSG_BVC_RESET_ACK MSG_STATUS_error MSG_STATUS MSG_NS_CONGESTION_INDICATION MSG_NS_STATUS_INDICATION MSG_NS_ERROR_INDICATION MSG_PACKET_CHANNEL_REQUEST MSG_PACKET_RESOURCE_REQUEST MSG_PACKET_RESOURCE_REQUEST_KO MSG_PACKET_DOWNLINK_ACKNACK MSG_PACKET_DOWNLINK_ACKNACK_KO MSG_PACKET_CONTROL_ACKNOWLEDGE MSG_PACKET_CONTROL_ACKNOWLEDGE_KO MSG_PACKET_UPLINK_DUMMY_CONTROL_BLOCK MSG_UPLINK_RLC_DATA_BLOCK MSG_UPLINK_RLC_DATA_BLOCK_KO MSG_PACKET_ACCESS_REJECT MSG_FA_In_Progress MSG_TA_In_Progress MSG_TA_Achieved MSG_TA_Error MSG_BN_Internal_Error MSG_FA_Error MSG_CRC_Error MSG_TEST_TO_AbIC
618

Value 0x10 0x11 0x12 0x13 0x14 0x15 0x16 0x17 0x18 0x19 0x1a 0x1b 0x1c 0x1d 0x1e 0x1f 0x20 0x21 0x22 0x22 0x23 0x24 0x25 0x26 0x27 0x28 0x29 0x2a 0x2b 0x2d 0x2e 0x2f 0x30 0x31 0x32 0x33 0x34 0x35 0x36 0x37 0x38 0x39 0x3a 0x40 0x41 0x42 0x43 0x44 0x45 0x46 0x47
A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

CONST MSG_IMMEDIATE_ASSIGNMENT MSG_ASSIGNMENT_REJECT MSG_PDCH_RELEASE MSG_GPRS_PAGING_PS MSG_GPRS_PAGING_CS MSG_PCUC_Overload_Detected MSG_BVC_Reset_Failed MSG_BVC_Block_Failed MSG_BVC_Unblock_Failed MSG_BVC_Reset_Complete MSG_BVC_Block_Complete MSG_BVC_Unblock_Complete MSG_BVC_Reset_Start MSG_BVC_Block_Start_to_TDPC MSG_BVC_Unblock_Start MSG_Signalling_Reset_Received MSG_Signalling_Reset_Complete MSG_BSS_Restart_ACK MSG_BSS_Restart_NACK MSG_BSS_Gb_Unavailable_ACK MSG_RADIO_STATUS MSG_FLUSH_LL_ACK MSG_LLC_DISCARDED MSG_FLOW_CONTROL_BVC MSG_BVC_BLOCK MSG_BVC_UNBLOCK MSG_PTP_STATUS MSG_SIG_STATUS MSG_UL_UNITDATA MSG_UL_UNITDATA_TEST MSG_DL_Activate MSG_LLC_Received MSG_PDTCH_Rel_FLUSH MSG_PDTCH_Rel_Status MSG_PDTCH_Rel_Reset MSG_PDTCH_Rel_Gb_Unavailable MSG_PDTCH_Reconfigure MSG_PDCH_REQUEST MSG_Align_Stop_ACK MSG_TLLI_Received MSG_UL_KILL MSG_FLUSH_Tra_Old MSG_FLUSH_Tra_New MSG_DL_Activate_FLUSH MSG_Polling_TA_ACK MSG_DL_START_TBF MSG_Start_UP MSG_SEND_PDAS MSG_SEND_IMMASS

Value 0x50 0x51 0x52 0x53 0x54 0x55 0x60 0x61 0x62 0x63 0x64 0x65 0x66 0x67 0x68 0x69 0x6a 0x6b 0x6c 0x6d 0x72 0x73 0x74 0x75 0x76 0x77 0x78 0x79 0x7a 0x7b 0x80 0x81 0x82 0x83 0x84 0x85 0x86 0x90 0x91 0x92 0x93 0x94 0x95 0x96 0x97 0x98 0x99 0x9a 0x9b

A30808-X3247-K240-3-7619

619

Outputs OML:BSC

Base Station Controller

CONST MSG_Single_Block_Req MSG_UL_PDTCH_Req MSG_DL_PDTCH_Req MSG_UL_TBF_Rem MSG_DL_TBF_Add MSG_DL_TBF_Rem MSG_UL_TBFPDT_Add MSG_UL_TBFPDT_Rem MSG_DL_TBFPDT_Add MSG_DL_TBFPDT_Rem MSG_UL_REM_ACK MSG_SB_TAI_Remove

Value 0xa0 0xa1 0xa2 0xa3 0xa4 0xa5 0xa6 0xa7 0xa8 0xa9 0xaa 0xab

MSG_PFR_RECONF MSG_PFR_StrTimeRchd MSG_PFR_MAKE MSG_TBF_SCHEDULER_START MSG_UL_PDTCH_OK MSG_UL_PDTCH_KO MSG_DL_PDTCH_OK MSG_DL_PDTCH_KO MSG_PDTCH_Abnormal_Rel MSG_Single_Block_OK MSG_Single_Block_KO MSG_T3191_Start MSG_DL_Ass_Sent MSG_UL_TFI_Remove MSG_DL_TFI_Remove MSG_UL_PDTCH_Rel MSG_DL_PDTCH_Rel MSG_UL_PDTCH_Abnormal_Rel MSG_DL_PDTCH_Abnormal_Rel MSG_UL_Active MSG_UL_TBF_Active MSG_DL_TBF_Active MSG_DL_Deactivate MSG_Align_Start MSG_Align_Stop MSG_Align_OK MSG_Align_KO MSG_UL_TBF_Add MSG_PDT_Release MSG_RECONF_OK MSG_DL_RECONF MSG_UL_MS_RECONF MSG_ACTIVATE_PDS_SCHEDULER MSG_UL_RECONF MSG_FROM_TL3OM_BVCI MSG_FROM_TL3OM_PCU MSG_FROM_TL3RM_BVCI
620

0xac 0xad 0xae 0xaf 0xb1 0xb2 0xb3 0xb4 0xb5 0xb6 0xb7 0xb8 0xb9 0xba 0xbb 0xbc 0xbd 0xbe 0xbf 0xc0 0xc1 0xc3 0xc4 0xc5 0xc6 0xc7 0xc8 0xc9 0xca 0xcb 0xcc 0xcd 0xce 0xcf 0xd0 0xd1 0xd2
A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

CONST MSG_FROM_TL3RM_PCU MSG_DATA_FROM_GbIC MSG_SIG_FROM_GbIC MSG_FROM_AbIC MSG_OM_BVCI_MESSAGE MSG_OM_PCU_MESSAGE MSG_RM_BVCI_MESSAGE MSG_RM_PCU_MESSAGE MSG_NS_UNITDATA_REQUEST_DATA MSG_NS_UNITDATA_REQUEST_SIG MSG_PK_DL_ASS_OK MSG_PCH_START_INIT MSG_PTPPKF_UPDATE MSG_ERROR MSG_ERROR_DETECTED MSG_NSE_Release MSG_SPARE

Value 0xd3 0xd4 0xd5 0xd6 0xd7 0xd8 0xd9 0xda 0xdb 0xdc 0xde 0xdf 0xe1 0xe9 0xf0 0xf1 0xff

Translation table for 'Code Message' as timer expired in the UPK errors when the Originator Process is EDOS Timer Handler

BSSGP_T1 BSSGP_T2 TF1 BVC Management Internal Timers PDCH Management Internal Timers EMPTY_CHANNEL_TIMER RLC_T3169_TIMER RLC_T3191_TIMER RLC_T3193_TIMER RLC_T3195_TIMER TBF Management Internal Timers General Purpose Internal Timers

0x01 0x02 0x03 0x04 0x0f 0x00 + 0x10 0x1d 0x13 0x21 0x22 0x23 0x24 0x25 0x38 0xdf .. 0xe0

A30808-X3247-K240-3-7619

621

Outputs OML:BSC

Base Station Controller

Annex E

RTE SYSTEM INFO REPORT

INIT_COMPLETED (case "RTE+ Error Loop"): name = <RUN TIME DETERMINATED> eventIdentifier = INITIALIZATION_COMPLETED originator = 410 MOSKNMSEH, 901 TOSKNMSEH, 950 UOSKNMSEH, 982 YOSKNMSEH, 992 NOSKNMSEH callStack (7 entries; call reverse order: first entry = last call) H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX processorRegister32Bit (EAX)H`XXXXXXXX (EBX)H`XXXXXXXX (ECX)H`XXXXXXXX (EDX)H`XXXXXXXX (ESI) H`XXXXXXXX (EDI)H`XXXXXXXX (ESP)H`XXXXXXXX (EBP)H`XXXXXXXX (EIP)H`XXXXXXXX (FLAGS)H`XXXXXXXX processorRegister16Bit (CS)H`XXXX (DS)H`XXXX (ES)H`XXXX (FS)H`XXXX (GS)H`XXXX (SS)H`XXXX interruptType = H`XXXX taskEntryPoint (selector)H`XXXXXXXX (offset)H`XXXXXXXX callStack (7 entries; call reverse order: first entry = last call) H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX processorRegister32Bit (EAX)H`XXXXXXXX (EBX)H`XXXXXXXX (ECX)H`XXXXXXXX (EDX)H`XXXXXXXX (ESI) H`XXXXXXXX (EDI)H`XXXXXXXX (ESP)H`XXXXXXXX (EBP)H`XXXXXXXX (EIP)H`XXXXXXXX (FLAGS)H`XXXXXXXX processorRegister16Bit (CS)H`XXXX (DS)H`XXXX (ES)H`XXXX (FS)H`XXXX (GS)H`XXXX (SS)H`XXXX interruptType = H`XXXX taskEntryPoint (selector)H`XXXXXXXX (offset)H`XXXXXXXX initializationStatus H`XXXX H`XXXX H`XXXX H`XXXX H`XXXX H`XXXX (current level) (BU ACTIVE) (BU STANDBY) (FULL) (TASK PRIME) (TASK SPARE) memoryPoolStatus (max 16 entries; A = pool_state; BCD = blk_avbl) H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD

622

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

INIT_COMPLETED (case "pSOS Error Loop"): name = <RUN TIME DETERMINATED> eventIdentifier = INITIALIZATION_COMPLETED originator = 410 MOSKNMSEH callStack (7 entries; call reverse order: first entry = last call) H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX processorRegister32Bit (EAX)H`XXXXXXXX (EBX)H`XXXXXXXX (ECX)H`XXXXXXXX (EDX)H`XXXXXXXX (ESI) H`XXXXXXXX (EDI)H`XXXXXXXX (ESP)H`XXXXXXXX (EBP)H`XXXXXXXX (EIP)H`XXXXXXXX (FLAGS)H`XXXXXXXX processorRegister16Bit (CS)H`XXXX (DS)H`XXXX (ES)H`XXXX (FS)H`XXXX (GS)H`XXXX (SS)H`XXXX interruptType = H`XXXX taskEntryPoint (selector)H`FFFFFFFF (offset)H`XXXXXXXX callStack (7 entries; call reverse order: first entry = last call) H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX processorRegister32Bit (EAX)H`XXXXXXXX (EBX)H`XXXXXXXX (ECX)H`XXXXXXXX (EDX)H`XXXXXXXX (ESI) H`XXXXXXXX (EDI)H`XXXXXXXX (ESP)H`XXXXXXXX (EBP)H`XXXXXXXX (EIP)H`XXXXXXXX (FLAGS)H`XXXXXXXX processorRegister16Bit (CS)H`XXXX (DS)H`XXXX (ES)H`XXXX (FS)H`XXXX (GS)H`XXXX (SS)H`XXXX interruptType = H`XXXX taskEntryPoint (selector)H`FFFFFFFF (offset)H`XXXXXXXX initializationStatus H`XXXX H`XXXX H`XXXX H`XXXX H`XXXX H`XXXX (current level) (BU ACTIVE) (BU STANDBY) (FULL) (TASK PRIME) (TASK SPARE) memoryPoolStatus (max 16 entries; A = pool_state; BCD = blk_avbl) H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD

NOTE: The content of taskEntryPoint selector field is not meaningful.

A30808-X3247-K240-3-7619

623

Outputs OML:BSC
INIT_COMPLETED (cases "Abort Routine" / "Initialization Function deleted"):

Base Station Controller

name = <RUN TIME DETERMINATED> eventIdentifier = INITIALIZATION_COMPLETED originator = 410 MOSKNMSEH, 901 TOSKNMSEH, 950 UOSKNMSEH, 982 YOSKNMSEH, 992 NOSKNMSEH callStack (7 entries; call reverse order: first entry = last call) H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX processorRegister32Bit (EAX)H`XXXXXXXX (EBX)H`XXXXXXXX (ECX)H`XXXXXXXX (EDX)H`XXXXXXXX (ESI) H`XXXXXXXX (EDI)H`XXXXXXXX (ESP)H`XXXXXXXX (EBP)H`XXXXXXXX (EIP)H`XXXXXXXX (FLAGS)H`XXXXXXXX processorRegister16Bit (CS)H`XXXX (DS)H`XXXX (ES)H`XXXX (FS)H`XXXX (GS)H`XXXX (SS)H`XXXX interruptType = H`XXXX taskEntryPoint (selector)H`XXXXXXXX (offset)H`XXXXXXXX callStack (7 entries; call reverse order: first entry = last call) H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX initializationStatus H`XXXX H`XXXX H`XXXX H`XXXX H`XXXX H`XXXX (current level) (BU ACTIVE) (BU STANDBY) (FULL) (TASK PRIME) (TASK SPARE) memoryPoolStatus (max 16 entries; A = pool_state; BCD = blk_avbl) H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD

NOTE: You can distinguish between cases by analysing the content of the second callStack group.

624

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

INIT_COMPLETED (case "RTE+ Threshold Overflow"): name = <RUN TIME DETERMINATED> eventIdentifier = INITIALIZATION_COMPLETED originator = 410 MOSKNMSEH, 901 TOSKNMSEH callStack (7 entries; call reverse order: first entry = last call) H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX processorRegister32Bit (EAX)H`XXXXXXXX (EBX)H`XXXXXXXX (ECX)H`XXXXXXXX (EDX)H`XXXXXXXX (ESI) H`XXXXXXXX (EDI)H`XXXXXXXX (ESP)H`XXXXXXXX (EBP)H`XXXXXXXX (EIP)H`XXXXXXXX (FLAGS)H`XXXXXXXX processorRegister16Bit (CS)H`XXXX (DS)H`XXXX (ES)H`XXXX (FS)H`XXXX (GS)H`XXXX (SS)H`XXXX interruptType = H`XXXX taskEntryPoint (selector)H`XXXXXXXX (offset)H`XXXXXXXX callStack (7 entries; call reverse order: first entry = last call) H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX initializationStatus H`XXXX H`XXXX H`XXXX H`XXXX H`XXXX H`XXXX (current level) (BU ACTIVE) (BU STANDBY) (FULL) (TASK PRIME) (TASK SPARE) memoryPoolStatus (max 16 entries; A = pool_state; BCD = blk_avbl) H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD otherInfo H`AA where: AA =

Initialization cause. It assumes the following value: 0x02 (RTE_ON) => The initialization is caused by a threshold overflow during multiple RTE+ task deletion.

A30808-X3247-K240-3-7619

625

Outputs OML:BSC
INIT_COMPLETED (cases "pSOS Abort Routine" / "pSOS Threshold Overflow"): name = <RUN TIME DETERMINATED> eventIdentifier = INITIALIZATION_COMPLETED originator = 410 MOSKNMSEH

Base Station Controller

callStack (7 entries; call reverse order: first entry = last call) H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX processorRegister32Bit (EAX)H`XXXXXXXX (EBX)H`XXXXXXXX (ECX)H`XXXXXXXX (EDX)H`XXXXXXXX (ESI) H`XXXXXXXX (EDI)H`XXXXXXXX (ESP)H`XXXXXXXX (EBP)H`XXXXXXXX (EIP)H`XXXXXXXX (FLAGS)H`XXXXXXXX processorRegister16Bit (CS)H`XXXX (DS)H`XXXX (ES)H`XXXX (FS)H`XXXX (GS)H`XXXX (SS)H`XXXX interruptType = H`XXXX taskEntryPoint (selector)H`FFFFFFFF (offset)H`XXXXXXXX callStack (7 entries; call reverse order: first entry = last call) H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX initializationStatus H`XXXX H`XXXX H`XXXX H`XXXX H`XXXX H`XXXX (current level) (BU ACTIVE) (BU STANDBY) (FULL) (TASK PRIME) (TASK SPARE) memoryPoolStatus (max 16 entries; A = pool_state; BCD = blk_avbl) H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD otherInfo H`AA H`BB H`CC H`DD H`DD H`DD H`DD H`EE H`EE H`EE H`EE where: AA =

Initialization cause. It can assume one of the following values: 0x01 (PSOS_AR_ON) => The initialization is caused by a pSOS task abort routine.

0x03 (PSOS_ON)
BB =

=> The initialization is caused by a threshold overflow during multiple pSOS task deletion.

Task type. It can assume one of the following values: 0x00 (START_TSK) => A simple start of the task is performed.

0x01 (RESTART_TSK) => All resources are released and a new start of the task is performed.
0x02 0x03 0x04 0x63 (ABORT_TSK) => Current task deletion is performed making a restart of the task with abort parameter. (FULL_INIT) => A FULL initialization is performed. (TASKPRIME_INIT) => A TASK PRIME initialization is performed (default value). (INVALID_TSK) => Invalid value.

CC = Abort action. It can assume one of the following values:


0x00 0x01 0x02 0x03 0x04 0x05 0x06 0x63 (COSKN_RTE) (COSKN_IPC) => A pSOS task executing a RTE+ application. => A pSOS task belonging to Interprocessor Communication. (COSKN_AGENT) => A pSOS task belonging to Agent. (COSKN_STACK) => A pSOS task belonging to Stack OSI. (COSKN_SDL) => A pSOS task belonging to Software DownLoad. (COSKN_GENERIC) => A generic pSOS task (default value). (COSKN_SYSTEM) => A system pSOS task. (COSKN_INVALID) => Invalid value.

DD = pSOS identifier of the task in which the exception has occurred (the value 0x00000000 makes the field invalid and meaningless).
EE = pSOS task entry point (the value 0xFFFFFFFF makes the field invalid and meaningless).

NOTE: You can distinguish between cases by analysing the content of the first byte in the otherInfo field. The content of taskEntryPoint selector field is not meaningful.

626

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

INIT_COMPLETED (case "SysInit call"): name = <RUN TIME DETERMINATED> eventIdentifier = INITIALIZATION_COMPLETED originator = 410 MOSKNMSEH, 901 TOSKNMSEH, 950 UOSKNMSEH, 982 YOSKNMSEH, 992 NOSKNMSEH callStack (7 entries; call reverse order: first entry = last call) H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX initializationStatus H`XXXX H`XXXX H`XXXX H`XXXX H`XXXX H`XXXX (current level) (BU ACTIVE) (BU STANDBY) (FULL) (TASK PRIME) (TASK SPARE) memoryPoolStatus (max 16 entries; A = pool_state; BCD = blk_avbl) H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD

A30808-X3247-K240-3-7619

627

Outputs OML:BSC
INIT_COMPLETED (case "SysInit from Firmware after a switch"):

Base Station Controller

name = <RUN TIME DETERMINATED> eventIdentifier = INITIALIZATION_COMPLETED originator = 410 MOSKNMSEH, 901 TOSKNMSEH, 950 UOSKNMSEH, 982 YOSKNMSEH, 992 NOSKNMSEH initializationStatus H`XXXX H`XXXX H`XXXX H`XXXX H`XXXX H`XXXX (current level) (BU ACTIVE) (BU STANDBY) (FULL) (TASK PRIME) (TASK SPARE) memoryPoolStatus (max 16 entries; A = pool_state; BCD = blk_avbl) H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD H`ABCD

628

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

INIT_COMPLETED (case "SysInit from Firmware after a software load"): name = <RUN TIME DETERMINATED> eventIdentifier = INITIALIZATION_COMPLETED originator = 410 MOSKNMSEH, 901 TOSKNMSEH, 950 UOSKNMSEH, 982 YOSKNMSEH, 992 NOSKNMSEH initializationStatus H`XXXX H`XXXX H`XXXX H`XXXX H`XXXX H`XXXX (current level) (BU ACTIVE) (BU STANDBY) (FULL) (TASK PRIME) (TASK SPARE)

A30808-X3247-K240-3-7619

629

Outputs OML:BSC
DEL_CURR_TSK (case from RTE+):

Base Station Controller

name = <RUN TIME DETERMINATED> eventIdentifier = CURRENT_TASK_DELETED originator = 410 MOSKNMSEH, 901 TOSKNMSEH, 950 UOSKNMSEH, 982 YOSKNMSEH, 992 NOSKNMSEH callStack (7 entries; call reverse order: first entry = last call) H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX processorRegister32Bit (EAX)H`XXXXXXXX (EBX)H`XXXXXXXX (ECX)H`XXXXXXXX (EDX)H`XXXXXXXX (ESI) H`XXXXXXXX (EDI)H`XXXXXXXX (ESP)H`XXXXXXXX (EBP)H`XXXXXXXX (EIP)H`XXXXXXXX (FLAGS)H`XXXXXXXX processorRegister16Bit (CS)H`XXXX (DS)H`XXXX (ES)H`XXXX (FS)H`XXXX (GS)H`XXXX (SS)H`XXXX interruptType = H`XXXX taskEntryPoint (selector)H`XXXXXXXX (offset)H`XXXXXXXX

NOTE: This message is related to one of the following BSC SOFTWARE ERROR specific problems: 51, DELETED CURRENT TASK 314, DELETED CURRENT TASK LOWINIT 315, DELETED CURRENT TASK UPPINIT For more details, please refers to the errors above.

630

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

DEL_CURR_TSK (case from pSOS): name = <RUN TIME DETERMINATED> eventIdentifier = CURRENT_TASK_DELETED originator = 410 MOSKNMSEH callStack (7 entries; call reverse order: first entry = last call) H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX processorRegister32Bit (EAX)H`XXXXXXXX (EBX)H`XXXXXXXX (ECX)H`XXXXXXXX (EDX)H`XXXXXXXX (ESI) H`XXXXXXXX (EDI)H`XXXXXXXX (ESP)H`XXXXXXXX (EBP)H`XXXXXXXX (EIP)H`XXXXXXXX (FLAGS)H`XXXXXXXX processorRegister16Bit (CS)H`XXXX (DS)H`XXXX (ES)H`XXXX (FS)H`XXXX (GS)H`XXXX (SS)H`XXXX interruptType = H`XXXX taskEntryPoint (selector)H`FFFFFFFF (offset)H`XXXXXXXX otherInfo H`AA H`BB H`CC H`CC H`CC H`CC H`DD H`DD H`DD H`DD where: AA = Task type. It can assume one of the following values: 0x00 (START_TSK) => A simple start of the task is performed.

0x01 (RESTART_TSK) => All resources are released and a new start of the task is performed.
0x02 0x03 0x04 0x63 (ABORT_TSK) => Current task deletion is performed making a restart of the task with abort parameter. (FULL_INIT) => A FULL initialization is performed. (TASKPRIME_INIT) => A TASK PRIME initialization is performed (default value). (INVALID_TSK) => Invalid value.

BB = Abort action. It can assume one of the following values:


0x00 0x01 0x02 0x03 0x04 0x05 0x06 0x63 (COSKN_RTE) (COSKN_IPC) => A pSOS task executing a RTE+ application. => A pSOS task belonging to Interprocessor Communication. (COSKN_AGENT) => A pSOS task belonging to Agent. (COSKN_STACK) => A pSOS task belonging to Stack OSI. (COSKN_SDL) => A pSOS task belonging to Software DownLoad. (COSKN_GENERIC) => A generic pSOS task (default value). (COSKN_SYSTEM) => A system pSOS task. (COSKN_INVALID) => Invalid value.

CC = pSOS identifier of the task in which the exception has occurred (the value 0x00000000 makes the field invalid and meaningless). DD = pSOS task entry point (the value 0xFFFFFFFF makes the field invalid and meaningless).

NOTE: This message is related to one of the following BSC SOFTWARE ERROR specific problems: 51, DELETED CURRENT TASK 314, DELETED CURRENT TASK LOWINIT 315, DELETED CURRENT TASK UPPINIT For more details, please refers to the errors above. The content of taskEntryPoint selector field is not meaningful.

A30808-X3247-K240-3-7619

631

Outputs OML:BSC
DEL_CURR_SWF:

Base Station Controller

name = <RUN TIME DETERMINATED> eventIdentifier = CURRENT_SWF_DELETED originator = 410 MOSKNMSEH, 901 TOSKNMSEH, 950 UOSKNMSEH, 982 YOSKNMSEH, 992 NOSKNMSEH callStack (7 entries; call reverse order: first entry = last call) H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX processorRegister32Bit (EAX)H`XXXXXXXX (EBX)H`XXXXXXXX (ECX)H`XXXXXXXX (EDX)H`XXXXXXXX (ESI) H`XXXXXXXX (EDI)H`XXXXXXXX (ESP)H`XXXXXXXX (EBP)H`XXXXXXXX (EIP)H`XXXXXXXX (FLAGS)H`XXXXXXXX processorRegister16Bit (CS)H`XXXX (DS)H`XXXX (ES)H`XXXX (FS)H`XXXX (GS)H`XXXX (SS)H`XXXX interruptType = H`XXXX taskEntryPoint (selector)H`XXXXXXXX (offset)H`XXXXXXXX

NOTE: This message is related to one of the following BSC SOFTWARE ERROR specific problems: 51, DELETED CURRENT TASK 314, DELETED CURRENT TASK LOWINIT 315, DELETED CURRENT TASK UPPINIT For more details, please refers to the errors above.

632

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

MSG_AUDIT_ERROR: name = <RUN TIME DETERMINATED> eventIdentifier = MESSAGES_AUDIT_ERROR originator = 410 MOSKNMSEH, 901 TOSKNMSEH, 950 UOSKNMSEH, 982 YOSKNMSEH, 992 NOSKNMSEH msgCntr (max 16 entries; High Byte=bad_msg_cntr; Low H`XXXX H`XXXX H`XXXX H`XXXX H`XXXX H`XXXX H`XXXX H`XXXX H`XXXX H`XXXX H`XXXX H`XXXX dumpMessage (max 5 entries; msg header) H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX . . . . . . . . otherInfo (one entry for every dumpMessage) H`AA H`BB H`CC H`DD H`EE H`FF . . . . where: DDCCBBAA = Link to the next message EE = Link type FF = Pool type HHGG = Message owner identifier Byte=lost_msg_cntr) H`XXXX H`XXXX H`XXXX H`XXXX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX

H`GG

H`HH

A30808-X3247-K240-3-7619

633

Outputs OML:BSC
DEL_CURR_INIT_FUN:

Base Station Controller

name = <RUN TIME DETERMINATED> eventIdentifier = CURR_INIT_FUNCT_DELETED originator = 410 MOSKNMSEH, 901 TOSKNMSEH, 950 UOSKNMSEH, 982 YOSKNMSEH, 992 NOSKNMSEH processorRegister32Bit (EAX)H`XXXXXXXX (EBX)H`XXXXXXXX (ECX)H`XXXXXXXX (EDX)H`XXXXXXXX (ESI) H`XXXXXXXX (EDI)H`XXXXXXXX (ESP)H`XXXXXXXX (EBP)H`XXXXXXXX (EIP)H`XXXXXXXX (FLAGS)H`XXXXXXXX processorRegister16Bit (CS)H`XXXX (DS)H`XXXX (ES)H`XXXX (FS)H`XXXX (GS)H`XXXX (SS)H`XXXX interruptType = H`XXXX callStack (7 entries; call reverse order: first entry = last call) H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX taskEntryPoint H`0 H`XXXXXXXX (init. table index of the deleted function) initializationStatus H`XXXX H`XXXX H`XXXX H`XXXX H`XXXX H`XXXX (current level) (BU ACTIVE) (BU STANDBY) (FULL) (TASK PRIME) (TASK SPARE)

634

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

SCH_AUDIT_ERROR_TSKINFO: name = <RUN TIME DETERMINATED> eventIdentifier = SCH_AUDIT_ERROR_TASK_INFO originator = 410 MOSKNMSEH, 901 TOSKNMSEH, 950 UOSKNMSEH, 982 YOSKNMSEH, 992 NOSKNMSEH callStack (7 entries; call reverse order: first entry = last call) H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX processorRegister32Bit (EAX)H`XXXXXXXX (EBX)H`XXXXXXXX (ECX)H`XXXXXXXX (EDX)H`XXXXXXXX (ESI) H`XXXXXXXX (EDI)H`XXXXXXXX (ESP)H`XXXXXXXX (EBP)H`XXXXXXXX (EIP)H`XXXXXXXX (FLAGS)H`XXXXXXXX where: EAX = Current Task priority EBX = EBX ECX = 0 (not meaningful) EDX = number of messages hold in all the task mailboxes ESI = ESI EDI = EDI ESP = 0 (not meaningful) EBP = EBP EIP = EIP FLAGS = number of mailboxes of the current task processorRegister16Bit (not meaningful) (CS)H`XXXX (DS)H`XXXX (ES)H`XXXX (FS)H`XXXX (GS)H`XXXX (SS)H`XXXX interruptType = H`XXXX (Priority Queue Jump Counter) taskEntryPoint (selector)H`XXXXXXXX (offset)H`XXXXXXXX

WARNING: the contents of some fields are different than label; see above for more details.

A30808-X3247-K240-3-7619

635

Outputs OML:BSC
MBX_OVF (standard):

Base Station Controller

name = <RUN TIME DETERMINATED> eventIdentifier = MAILBOX_OVERFLOW originator = 410 MOSKNMSEH, 901 TOSKNMSEH, 950 UOSKNMSEH, 982 YOSKNMSEH, 992 NOSKNMSEH callStack (7 entries; call reverse order: first entry = last call) H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX msgCntr (11 entries) (1)H`BAC0 (2)H`XXXX (3)H`XXXX (4)H`XXXX (5)H`XXXX (6)H`XXXX (7)H`XXXX (8)H`XXXX (9)H`XXXX (10)H`XXXX (11)H`XXXX where: (1) = 251 compatibility (not meaningful) (2) = Mailbox logical name (3) = Configured messages number (4) = Current messages number (5) = Dynamic messages threshold (6) = Dumped data amount (7 - 11) = Dumped messages positions in the mailbox dumpMessage (max 5 entries; msg header and/or msg data) H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX . . . . . . . . otherInfo H`A1 H`A2 H`A3 H`A4 . . . . (the number of entries is equal to dumpMessage) H`B1 H`B2 H`B3 H`B4 (1 entry) H`C1 H`C2 H`C3 H`C4 (1 entry) H`D1 H`D2 H`D3 H`D4 (1 entry) H`E1 H`E2 H`E3 H`E4 (1 entry) H`F1 (1 entry) H`G1 H`G2 (1 entry) H`H1 H`H2 (1 entry) where: A4A3A2A1 B4B3B2B1 C4C3C2C1 D4D3D2D1 E4E3E2E1 F1 G2G1 H2H1

= = = = = = = =

Link of a previous dumped message to the next one Counter value (indicating current time slot) Finer counter value (indicating time inside current time slot) Name of the task interrupted by last tick (meaningful only for pSOS) Entry point of the task interrupted by last tick Priority of the task interrupted by last tick Prime time average value Total time average value

636

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

MBX_OVF (extended): name = <RUN TIME DETERMINATED> eventIdentifier = MAILBOX_OVERFLOW originator = 410 MOSKNMSEH, 901 TOSKNMSEH, 950 UOSKNMSEH, 982 YOSKNMSEH, 992 NOSKNMSEH callStack (7 entries; call reverse order: first entry = last call) H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX callStack (7 entries; call reverse order: first entry = last call) H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX processorRegister32Bit (EAX)H`XXXXXXXX (EBX)H`XXXXXXXX (ECX)H`XXXXXXXX (EDX)H`XXXXXXXX (ESI) H`XXXXXXXX (EDI)H`XXXXXXXX (ESP)H`XXXXXXXX (EBP)H`XXXXXXXX (EIP)H`XXXXXXXX (FLAGS)H`XXXXXXXX where: EAX = 0 (not meaningful) EBX = EBX ECX = 0 (not meaningful) EDX = 0 (not meaningful ESI = ESI EDI = EDI ESP = 0 (not meaningful) EBP = EBP EIP = EIP (if Tick interrupt occurred) FLAGS = 0 (not meaningful) processorRegister16Bit (not meaningful) (CS)H`XXXX (DS)H`XXXX (ES)H`XXXX (FS)H`XXXX (GS)H`XXXX (SS)H`XXXX interruptType = H`XXXX (not meaningful) taskEntryPoint (selector)H`XXXXXXXX (offset)H`XXXXXXXX msgCntr (11 entries) (1)H`BAC0 (2)H`XXXX (3)H`XXXX (4)H`XXXX (5)H`XXXX (6)H`XXXX (7)H`XXXX (8)H`XXXX (9)H`XXXX (10)H`XXXX (11)H`XXXX where: (1) = 251 compatibility (not meaningful) (2) = Mailbox logical name (3) = Configured messages number (4) = Current messages number (5) = Dynamic messages threshold (6) = Dumped data amount (7 - 11) = Dumped messages positions in the mailbox dumpMessage (max 5 entries; msg header and/or msg data) H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX . . . . . . . . otherInfo H`A1 H`A2 H`A3 H`A4 . . . . (the number of entries is equal to dumpMessage) H`B1 H`B2 H`B3 H`B4 (1 entry) H`C1 H`C2 H`C3 H`C4 (1 entry) H`D1 H`D2 H`D3 H`D4 (1 entry) H`E1 H`E2 H`E3 H`E4 (1 entry) H`F1 (1 entry) H`G1 H`G2 (1 entry) H`H1 H`H2 (1 entry) where: A4A3A2A1 B4B3B2B1 C4C3C2C1 D4D3D2D1 E4E3E2E1 F1 G2G1 H2H1

= = = = = = = =

Link of a previous dumped message to the next one Counter value (indicating current time slot) Finer counter value (indicating time inside current time slot) Name of the task interrupted by last tick (meaningful only for pSOS) Entry point of the task interrupted by last tick Priority of the task interrupted by last tick Prime time average value Total time average value

NOTE: The second callStack, the processorRegister32Bit and the taskEntryPoint fields refer to the task that is retrieving messages from the mailbox.

A30808-X3247-K240-3-7619

637

Outputs OML:BSC
BAD_TMC_LINK:

Base Station Controller

name = <RUN TIME DETERMINATED> eventIdentifier = BAD_TIMING_CELLS_LINK originator = 410 MOSKNMSEH, 901 TOSKNMSEH, 950 UOSKNMSEH, 982 YOSKNMSEH, 992 NOSKNMSEH

638

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

SCHED_ERR: name = <RUN TIME DETERMINATED> eventIdentifier = SCHEDULER_ERROR originator = 410 MOSKNMSEH, 901 TOSKNMSEH, 950 UOSKNMSEH, 982 YOSKNMSEH, 992 NOSKNMSEH

A30808-X3247-K240-3-7619

639

Outputs OML:BSC
BAD_SUSP_LINK:

Base Station Controller

name = <RUN TIME DETERMINATED> eventIdentifier = BAD_SUSPENDED_LINK originator = 410 MOSKNMSEH, 901 TOSKNMSEH, 950 UOSKNMSEH, 982 YOSKNMSEH, 992 NOSKNMSEH

640

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

UNDECLARED_FUNCTION: name = <RUN TIME DETERMINATED> eventIdentifier = UNDECLARED_FUNCTION originator = 410 MOSKNMSEH, 901 TOSKNMSEH, 950 UOSKNMSEH, 982 YOSKNMSEH, 992 NOSKNMSEH callStack (7 entries; call reverse order: first entry = last call) H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX H`XXXXXXXX taskEntryPoint (selector)H`XXXXXXXX (offset)H`XXXXXXXX

A30808-X3247-K240-3-7619

641

Outputs OML:BSC
NULL_POINTER:

Base Station Controller

name = <RUN TIME DETERMINATED> eventIdentifier = NULL_POINTER originator = 410 MOSKNMSEH, 901 TOSKNMSEH, 950 UOSKNMSEH, 982 YOSKNMSEH, 992 NOSKNMSEH otherInfo H`XX (first 64 bytes data dump) H`XX H`XX H`XX H`XX H`XX H`XX H`XX

642

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

MBX_AUDIT_ERROR: name = <RUN TIME DETERMINATED> eventIdentifier = MAILBOXES_AUDIT_ERROR originator = 410 MOSKNMSEH, 901 TOSKNMSEH, 950 UOSKNMSEH, 982 YOSKNMSEH, 992 NOSKNMSEH otherInfo (pools number entries; released messages number) H`XX H`XX H`XX H`XX

A30808-X3247-K240-3-7619

643

Outputs OML:BSC
TSK_AUDIT_ERROR:

Base Station Controller

name = <RUN TIME DETERMINATED> eventIdentifier = TASKS_AUDIT_ERROR originator = 410 MOSKNMSEH, 901 TOSKNMSEH, 950 UOSKNMSEH, 982 YOSKNMSEH, 992 NOSKNMSEH otherInfo H`XX (1 entry; deleted tasks number)

644

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

MSG_POOL_ERROR: name = <RUN TIME DETERMINATED> eventIdentifier = MESSAGES_POOL_ERROR originator = 410 MOSKNMSEH, 901 TOSKNMSEH, 950 UOSKNMSEH, 982 YOSKNMSEH, 992 NOSKNMSEH dumpMessage (max 2 entries; corrupted msg header and the previous H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX H`XX . . . . otherInfo (max 2 entries; 1+6 bytes for each one) H`AA H`BB H`CC H`DD H`EE H`FF H`GG . . . . where: AA = Pool type passed in the m_get_blk() function GGFF:EEDDCCBB = Link to the next message one, if exists) H`XX H`XX H`XX H`XX

A30808-X3247-K240-3-7619

645

Outputs OML:BSC
GENERIC_ERROR:

Base Station Controller

name = <RUN TIME DETERMINATED> eventIdentifier = GENERIC_ERROR originator = 410 MOSKNMSEH, 901 TOSKNMSEH, 950 UOSKNMSEH, 982 YOSKNMSEH, 992 NOSKNMSEH

646

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Annex F

SYSTEM INFO REPORT

SYSINFO_ID: 001
SYSTEM INFO REPORT: Originator:

Memt Configuration Switched by System


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4605 MDHPRININ sysinfo description : This error is issued during the initialization phase when MPCC card could not reach TDPC card using the active MEMT, that is not failed, but using the other one. In this case the MEMT complex configuration is switched automatically by MPCC without error notification and without operator intervention. 1 = Line in the code where the system info is issued. 2 = Initialization level. 3 = Number of performed attempts to initialize TDPC. 4 = Old MEMT complex configuration before the initialization started. 5 = New MEMT complex configuration as chosen by MPCC card. 6 = Not used. 7 = Not used. 8 = Not used. 9 = Not used. 10 = Not used. 11 = Not used. 12 = Not used. 13 = Not used. 14 = Not used. 15 = Not used. 16 = Not used. 17 = Not used. 18 = Not used. 19 = Not used. 20 = Not used. 21 = Not used.
A30808-X3247-K240-3-7619 647

Outputs OML:BSC

Base Station Controller

22 = 23 = 24 = 25 = 26 = 27 = 28 = 29 = 30 = 31 = 32 =

Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

Case of XXXX = 4603 MDHPRDCUT sysinfo description : During the preliminary phase, before TDPC load starting, something goes wrong and the setup of the TDPC card is restarted but using the other MEMT card, if available. 1 = Line in the code where the system info is issued. 2 = Number of performed attempts to initialize TDPC. 3 = Old MEMT complex configuration before the init started. 4 = New MEMT complex configuration as chosen by MPCC card. 5 = Not used. 6 = Not used. 7 = Not used. 8 = Not used. 9 = Not used. 10 = Not used. 11 = Not used. 12 = Not used. 13 = Not used. 14 = Not used. 15 = Not used. 16 = Not used. 17 = Not used. 18 = Not used. 19 = Not used. 20 = Not used. 21 = Not used. 22 = Not used. 23 = Not used. 24 = Not used. 25 = Not used. 26 = Not used. 27 = Not used. 28 = Not used. 29 = Not used. 30 = Not used. 31 = Not used. 32 = Not used. ##fine##

648

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

SYSINFO_ID: 002
SYSTEM INFO REPORT: Originator:

EPWR not Reachable


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4606 MDHPRDCSA sysinfo description : This system info is issued against the EPWR card every time the opposite copy of IXLT goes disabled , this because its control points belongs to IXLT card. The state of the EPWR card does not change, but is no more possible to control it. 1 = Line in the code where the system info has been generated. 2 = Status bits of the card stored in device handler database. 3 = Not used 4 = Not used 5 = Not used 6 = Not used 7 = Not used 8 = Not used 9 = Not used 10 = Not used 11 = Not used 12 = Not used 13 = Not used 14 = Not used 15 = Not used 16 = Not used 17 = Not used 18 = Not used 19 = Not used 20 = Not used 21 = Not used 22 = Not used 23 = Not used 24 = Not used 25 = Not used 26 = Not used 27 = Not used 28 = Not used 29 = Not used 30 = Not used 31 = Not used 32 = Not used ##fine##

A30808-X3247-K240-3-7619

649

Outputs OML:BSC

Base Station Controller

SYSINFO_ID: 003
SYSTEM INFO REPORT: Originator:

NMI System Info


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4608 MDHPRDDNH sysinfo description : This system info contains all data useful for NMI handler analysis used by the MPCC NMI handler routine. 1 = Action performed by the NMI handler routine. 2 = Result of the NMI analysis. 3 = MPCC alarm register. 4 = MPCC control point register. 5 = MPCC mask register. 6 = MPCC sense point register. 7 = zeroed. 8 = zeroed. 9 = zeroed. 10 = PIC master in-service interrupts mask + PIC master interrupts enable mask. 11 = PIC slave in-service interrupt mask + PIC slave interrpts enable mask. 12 = MPCC internal NMI counter. 13 = Card identification + card number. 14 = Trapped address ( Lower part ). 15 = Trapped address ( Higher part ). 16 = Trapped data. 17 = Type of access allowed for trapped address. 18 = Selection mode allowed for trapped address. 19 = Card id transient NMI counter. 20 = PWRD fail mask + ME2M fail mask. 21 = MEMT fail mask + IXLT fail mask. 22 = DK40 fail mask + NTW fail mask. 23 = EPWR fail mask. 24 = LICD fail mask. 25 = PPXX fail mask (high). 26 = PPXX fail mask (low). 27 = Instruction pointer where NMI occurred ( high part). 28 = Instruction pointer where NMI occurred ( low part). 29 = MPCC alarm register used for internal alarm check. 30 = MPCC control point register after NMI analysis. 31 = zeroed. 32 = zeroed. Case of XXXX = 4901 TDHPRDDNN sysinfo description :
650 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

This system info contains all data useful for NMI handler analysis used by the TDPC NMI handler routine. 1 = Action performed by the NMI handler routine. 2 = Result of the NMI analysis. 3 = TDPC internal register (higher part). 4 = TDPC internal register (lower part). 5 = TDPC control point register. 6 = TDPC configuration register. 7 = TDPC external sense point register. 8 = PIC in-service interrupts mask. 9 = PIC interrupts enable mask. 10 = Card id + card number. 11 = Trapped address (higher part). 12 = Trapped address (lower part). 13 = Trapped data. 14 = Type of access allowed for trapped address. 15 = Selection mode allowed for trapped address. 16 = TDPC internal NMI counter. 17 = Card id transient NMI counter. 18 = Instruction pointer where NMI occurred (higher part). 19 = Instruction pointer where NMI occurred (lower part). 20 = Not used. 21 = Not used. 22 = Not used. 23 = Not used. 24 = Not used. 25 = Not used. 26 = Not used. 27 = Not used. 28 = Not used. 29 = Not used. 30 = Not used. 31 = Not used. 32 = Not used. ##fine##

A30808-X3247-K240-3-7619

651

Outputs OML:BSC

Base Station Controller

SYSINFO_ID: 004
SYSTEM INFO REPORT: Originator:

TDPC Log Base Data


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4603 MDHPRDCUT sysinfo description : This system information is issued when something goes wrong on TDPC card, HW or FW or SW problem. Its purpose is print out more information about the occurred problem. 1 = MPCC to TDPC control register lower word. 2 = MPCC to TDPC control register higher word. 3 = TDPC to MPCC sense register lower word. 4 = TDPC to MPCC sense register higher word. 5 = TDPC to MPCC ASCII coded load identificative. 6 = TDPC to MPCC ASCII coded load identificative. 7 = TDPC to MPCC ASCII coded load identificative. 8 = TDPC to MPCC ASCII coded load identificative. 9 = TDPC to MPCC ASCII coded load identificative. 10 = TDPC to MPCC ASCII coded load identificative. 11 = TDPC to MPCC ASCII coded load identificative. 12 = TDPC to MPCC ASCII coded load identificative. 13 = TDPC to MPCC ASCII coded load identificative. 14 = MPCC/MEMT check access reserved location. 15 = TDPC/MEMT check access reserved location. 16 = Not used. 17 = Not used. 18 = Not used. 19 = Not used. 20 = Not used. 21 = Not used. 22 = Not used. 23 = Not used. 24 = Not used. 25 = Not used. 26 = Not used. 27 = Not used. 28 = Not used. 29 = Not used. 30 = Not used. 31 = Not used. 32 = Not used. ##fine##

652

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

SYSINFO_ID: 005
SYSTEM INFO REPORT: Originator:

TDPC Log Trace Data


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4603 MDHPRDCUT sysinfo description : This system information is issued when something goes wrong on TDPC card, HW or FW or SW problem. Its purpose is print out more information about the occurred problem. 1 = Last originator of logrec upd queue. 2 = Last originator of logrec upd queue. 3 = Last originator of logrec upd queue. 4 = Last originator of logrec upd queue. 5 = Time stamp of last logrec update. 6 = Time stamp of last logrec update. 7 = Time stamp of last logrec update. 8 = Time stamp of last logrec update. 9 = Index of last value written in the originators queue + Memt interrupts counter. 10 = Nmi counters ( one byte for each initialization level ). 11 = Other exception counters. ( one byte for each initialization level ). 12 = Extended source of last log update. 13 = Extended source of last log update. 14 = TDPC internal control sense point register ( lower bits ). 15 = TDPC internal control sense point register ( higher bits ). 16 = TDPC internal trap register ( lower bits ).. 17 = TDPC internal trap register ( higher bits ).. 18 = PIC inservice bits + PIC active mask. 19 = TDPC GA control point register. 20 = TDPC GA trap register 1. 21 = TDPC GA trap register 2. 22 = TDPC GA trap register 3. 23 = MEMT complex configuration. 24 = TDPC GA external sense point. 25 = Not used. 26 = Not used. 27 = Not used. 28 = Not used. 29 = Not used. 30 = Not used. 31 = Not used. 32 = Not used. ##fine##

A30808-X3247-K240-3-7619

653

Outputs OML:BSC

Base Station Controller

SYSINFO_ID: 006
SYSTEM INFO REPORT: Originator:

TDPC Log Exception


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4603 MDHPRDCUT sysinfo description : This system information is issued when something goes wrong on TDPC card, HW or FW or SW problem. Its purpose is print out more information about the occurred problem. 1 = Time stamp. 2 = TDPC internal control sense point register ( lower bits ) before NMI occurred. 3 = TDPC internal control sense point register ( higher bits ) before NMI occurred.. 4 = TDPC internal trap register ( lower bits ) before NMI occurred.. 5 = TDPC internal trap register ( higher bits ) before NMI occurred.. 6 = PIC inservice bits + PIC active mask before NMI occurred.. 7 = TDPC GA control point register before NMI occurred.. 8 = TDPC GA trap register 1 before NMI occurred.. 9 = TDPC GA trap register 2 before NMI occurred.. 10 = TDPC GA trap register 3 before NMI occurred.. 11 = MEMT complex configuration before NMI occurred.. 12 = TDPC GA external sense point before NMI occurred.. 13 = Nmicard Id + nmi card number. 14 = Nmi decoded access type. 15 = Physical address of occurred nmi ( low bits ). 16 = Physical address of occurred nmi ( high bits ). 17 = Value trapped on data bus ( low bits ). 18 = Value trapped on data bus ( high bits ). 19 = Card selection mode. 20 = Specific card range offset. 21 = EIP where the nmi occurred ( low bits ). 22 = EIP whwre the nmi occurred ( high bits ). 23 = Nmi time. 24 = Nmi time. 25 = Nmi time. 26 = Nmi time. 27 = Not used. 28 = Not used. 29 = Not used. 30 = Not used. 31 = Not used. 32 = Not used. ##fine##

654

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

SYSINFO_ID: 007
SYSTEM INFO REPORT: Originator:

TDPC Log OS Data


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4603 MDHPRDCUT sysinfo description : This system information is issued when something goes wrong on TDPC card, HW or FW or SW problem. Its purpose is print out more information about the occurred problem. 1 = TDPC OS data [0] ( low bits ). 2 = TDPC OS data [0] ( high bits ). 3 = TDPC OS data [1] ( low bits ). 4 = TDPC OS data [1] ( high bits ). 5 = TDPC OS data [2] ( low bits ). 6 = TDPC OS data [2] ( high bits ). 7 = TDPC OS data [3] ( low bits ). 8 = TDPC OS data [3] ( high bits ). 9 = TDPC OS data [4] ( low bits ). 10 = TDPC OS data [4] ( high bits ). 11 = TDPC OS data [5] ( low bits ). 12 = TDPC OS data [5] ( high bits ). 13 = TDPC OS data [6] ( low bits ). 14 = TDPC OS data [6] ( high bits ). 15 = Not used. 16 = Not used. 17 = Not used. 18 = Not used. 19 = Not used. 20 = Not used. 21 = Not used. 22 = Not used. 23 = Not used. 24 = Not used. 25 = Not used. 26 = Not used. 27 = Not used. 28 = Not used. 29 = Not used. 30 = Not used. 31 = Not used. 32 = Not used. ##fine##

A30808-X3247-K240-3-7619

655

Outputs OML:BSC

Base Station Controller

SYSINFO_ID: 008
SYSTEM INFO REPORT: Originator:

TDPC Log Memt Data


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4603 MDHPRDCUT sysinfo description : This system information is issued when something goes wrong on TDPC or MET card, HW or FW or SW problem. Its purpose is print out more information about the occurred problem. The info. from 1 to 13 are intended for MEMT card copy 0, from 14 to 26 are releted to MEMT card copy 1 (HW state at the nmi). 1 = Code of occurred error on MEMT- 0. 2 = Code of occurred error on MEMT- 0. 3 = TDPC internal control sense point register ( lower bits ) before NMI occurred. 4 = TDPC internal control sense point register ( higher bits ) before NMI occurred.. 5 = TDPC internal trap register ( lower bits ) before NMI occurred.. 6 = TDPC internal trap register ( higher bits ) before NMI occurred.. 7 = PIC inservice bits + PIC active mask before NMI occurred.. 8 = TDPC GA control point register before NMI occurred.. 9 = TDPC GA trap register 1 before NMI occurred.. 10 = TDPC GA trap register 2 before NMI occurred.. 11 = TDPC GA trap register 3 before NMI occurred.. 12 = MEMT complex configuration before NMI occurred.. 13 = TDPC GA external sense point before NMI occurred.. 14 = Code of occurred error on MEMT- 1. 15 = Code of occurred error on MEMT- 1. 16 = TDPC internal control sense point register ( lower bits ) before NMI occurred. 17 = TDPC internal control sense point register ( higher bits ) before NMI occurred.. 18 = TDPC internal trap register ( lower bits ) before NMI occurred.. 19 = TDPC internal trap register ( higher bits ) before NMI occurred.. 20 = PIC inservice bits + PIC active mask before NMI occurred.. 21 = TDPC GA control point register before NMI occurred.. 22 = TDPC GA trap register 1 before NMI occurred.. 23 = TDPC GA trap register 2 before NMI occurred.. 24 = TDPC GA trap register 3 before NMI occurred.. 25 = MEMT complex configuration before NMI occurred.. 26 = TDPC GA external sense point before NMI occurred.. 27 = Not used. 28 = Not used. 29 = Not used. 30 = Not used. 31 = Not used. 32 = Not used. ##fine##

656

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

SYSINFO_ID: 009
SYSTEM INFO REPORT: Originator:

TDPC Log FW Data


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4600 MDHPRDCDE sysinfo description : This system information log to the output data written by fw when the status response is received. 1 = Diag result. 2 = Bus test result. 3 = Memory access test result. 4 = Gate Array test result. 5 = Chip select test result. 6 = PIC test result. 7 = PIT test result. 8 = Hw registers miscellaneous information. 9 = Spare word. 10 = Spare word. 11 = Spare word. 12 = Spare word. 13 = Spare word. 14 = Spare word. 15 = Spare word. 16 = Load presence flag. 17 = Not used. 18 = Not used. 19 = Not used. 20 = Not used. 21 = Not used. 22 = Not used. 23 = Not used. 24 = Not used. 25 = Not used. 26 = Not used. 27 = Not used. 28 = Not used. 29 = Not used. 30 = Not used. 31 = Not used. 32 = Not used. Case of XXXX = 4603 MDHPRDCUT sysinfo description :
A30808-X3247-K240-3-7619 657

Outputs OML:BSC

Base Station Controller

This system info stores additional infoes written by the TDPC FW itself that could be useful when something went wrong (E.g. TDPC load failure, diag failure, TDPC failure during download setup). 1 = Diag result. 2 = Bus test result. 3 = Memory access test result. 4 = Gate Array test result. 5 = Chip select test result. 6 = PIC test result. 7 = PIT test result. 8 = Hw registers miscellaneous information. 9 = Spare word. 10 = Spare word. 11 = Spare word. 12 = Spare word. 13 = Spare word. 14 = Spare word. 15 = Spare word. 16 = Load presence flag. 17 = Not used. 18 = Not used. 19 = Not used. 20 = Not used. 21 = Not used. 22 = Not used. 23 = Not used. 24 = Not used. 25 = Not used. 26 = Not used. 27 = Not used. 28 = Not used. 29 = Not used. 30 = Not used. 31 = Not used. 32 = Not used. Case of XXXX = 4606 MDHPRDCSA sysinfo description : This system information is issued when the TDPC diag fails. It contains information about the cause of the failure written by the TDPC FW itself. 1 = Diag result. 2 = Bus test result. 3 = Memory access test result. 4 = Gate Array test result. 5 = Chip select test result. 6 = PIC test result. 7 = PIT test result. 8 = Hw registers miscellaneous information. 9 = Spare word. 10 = Spare word. 11 = Spare word. 12 = Spare word. 13 = Spare word. 14 = Spare word. 15 = Spare word. 16 = Load presence flag. 17 = Not used.
658 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

18 = Not used. 19 = Not used. 20 = Not used. 21 = Not used. 22 = Not used. 23 = Not used. 24 = Not used. 25 = Not used. 26 = Not used. 27 = Not used. 28 = Not used. 29 = Not used. 30 = Not used. 31 = Not used. 32 = Not used. ##fine##

A30808-X3247-K240-3-7619

659

Outputs OML:BSC

Base Station Controller

SYSINFO_ID: 010
SYSTEM INFO REPORT: Originator:

TDPC Active Switched by System


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4605 MDHPRININ sysinfo description : This sysytem info is issued when, during a task initialization, the active TDPC copy changes, the system is not affected because the other copy starts immediately. 1 = Line in the code where the system info has been issued. 2 = High bits of the TDPC status owned by the device handler. 3 = Low bits of the TDPC status owned by the device handler. 4 = Initialization level. 5 = Old active TDPC copy. 6 = Not used. 7 = Not used. 8 = Not used. 9 = Not used. 10 = Not used. 11 = Not used. 12 = Not used. 13 = Not used. 14 = Not used. 15 = Not used. 16 = Not used. 17 = Not used. 18 = Not used. 19 = Not used. 20 = Not used. 21 = Not used. 22 = Not used. 23 = Not used. 24 = Not used. 25 = Not used. 26 = Not used. 27 = Not used. 28 = Not used. 29 = Not used. 30 = Not used. 31 = Not used. 32 = Not used. Case of XXXX = 4606 MDHPRDCSA
660 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

sysinfo description : This system info is issued when, during the normal exercise, the active TDPC card show some problem, for example its found alarmed, or in fw state, or there is a power off. In these cases the MPCC switch the active TDPC autonomously. The state/status of the old active TDPC card could change or not, dependes if a failure has been found. 1 = Line in the module where the system info has been issued. 2 = High bits of the TDPC status owned by the device handler. 3 = Low bits of the TDPC status owned by the device handler. 4 = Type of the problem that affected the TDPC card. 5 = Old active TDPC copy. 6 = Software item that recognized the TDPC problem. 7 = Line in the software item where the problem has been found. 8 = Not used. 9 = Not used. 10 = Not used. 11 = Not used. 12 = Not used. 13 = Not used. 14 = Not used. 15 = Not used. 16 = Not used. 17 = Not used. 18 = Not used. 19 = Not used. 20 = Not used. 21 = Not used. 22 = Not used. 23 = Not used. 24 = Not used. 25 = Not used. 26 = Not used. 27 = Not used. 28 = Not used. 29 = Not used. 30 = Not used. 31 = Not used. 32 = Not used. ##fine##

A30808-X3247-K240-3-7619

661

Outputs OML:BSC

Base Station Controller

SYSINFO_ID: 011
SYSTEM INFO REPORT: Originator:

TDPC Active Restarted by System


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4605 MDHPRININ sysinfo description : This sysytem info is issued when, during a task initialization, the active TDPC copy shows some problem but the device handler has restarted it without service loss. 1 = Line in the code where the system info has been issued. 2 = High bits of the TDPC status owned by the device handler. 3 = Low bits of the TDPC status owned by the device handler. 4 = Initialization level. 5 = Old active TDPC copy. 6 = Not used. 7 = Not used. 8 = Not used. 9 = Not used. 10 = Not used. 11 = Not used. 12 = Not used. 13 = Not used. 14 = Not used. 15 = Not used. 16 = Not used. 17 = Not used. 18 = Not used. 19 = Not used. 20 = Not used. 21 = Not used. 22 = Not used. 23 = Not used. 24 = Not used. 25 = Not used. 26 = Not used. 27 = Not used. 28 = Not used. 29 = Not used. 30 = Not used. 31 = Not used. 32 = Not used. Case of XXXX = 4606 MDHPRDCSA
662 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

sysinfo description : This system info is issued when, during the normal exercise, the active TDPC card show some problem, for example its found alarmed, or in fw state, or there is a power off. In these cases the MPCC restarted the TDPC autonomously, with a very little impact on the system. 1 = Line in the module where the system info has been issued. 2 = High bits of the TDPC status owned by the device handler. 3 = Low bits of the TDPC status owned by the device handler. 4 = Type of the problem that affected the TDPC card. 5 = Old active TDPC copy. 6 = Software item that recognized the TDPC problem. 7 = Line in the software item where the problem has been found. 8 = Not used. 9 = Not used. 10 = Not used. 11 = Not used. 12 = Not used. 13 = Not used. 14 = Not used. 15 = Not used. 16 = Not used. 17 = Not used. 18 = Not used. 19 = Not used. 20 = Not used. 21 = Not used. 22 = Not used. 23 = Not used. 24 = Not used. 25 = Not used. 26 = Not used. 27 = Not used. 28 = Not used. 29 = Not used. 30 = Not used. 31 = Not used. 32 = Not used. ##fine##

A30808-X3247-K240-3-7619

663

Outputs OML:BSC

Base Station Controller

SYSINFO_ID: 012
SYSTEM INFO REPORT: Originator:

Unable to Initialize TDPC SW


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4601 MDHPRDCMC sysinfo description : In this case the active TDPC did not complete the bring up init after the TDPC reload, MPCC recognize it and the current loading procedure is ended. After a while the device handler will ask a spontaneous tdpc reload. 1 = Line in the code where the system info has been formatted 2 = Status bits owned by the TDPC device handler ( low part ). 3 = Status bits owned by the TDPC device handler (high part). 4 = Event type handled by the device handler. 5 = Current device handler automa state. 6 = Not used. 7 = Not used. 8 = Not used. 9 = Not used. 10 = Not used. 11 = Not used. 12 = Not used. 13 = Not used. 14 = Not used. 15 = Not used. 16 = Not used. 17 = Not used. 18 = Not used. 19 = Not used. 20 = Not used. 21 = Not used. 22 = Not used. 23 = Not used. 24 = Not used. 25 = Not used. 26 = Not used. 27 = Not used. 28 = Not used. 29 = Not used. 30 = Not used. 31 = Not used. 32 = Not used.

664

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Case of XXXX = 4605 MDHPRININ sysinfo description : The current active TDPC card failed to start during the execution of a full init. The system try to do it reloading the TDPC with a bring up. 1 = Line in the code where the system info has been formatted. 2 = Requested initialization level. 3 = Number of performed attempts. 4 = Memory configuration. 5 = Code of the occurred error. 6 = Software module where error took place. 7 = Line in the software module where the error took place. 8 = Not used. 9 = Not used. 10 = Not used. 11 = Not used. 12 = Not used. 13 = Not used. 14 = Not used. 15 = Not used. 16 = Not used. 17 = Not used. 18 = Not used. 19 = Not used. 20 = Not used. 21 = Not used. 22 = Not used. 23 = Not used. 24 = Not used. 25 = Not used. 26 = Not used. 27 = Not used. 28 = Not used. 29 = Not used. 30 = Not used. 31 = Not used. 32 = Not used. ##fine##

A30808-X3247-K240-3-7619

665

Outputs OML:BSC

Base Station Controller

SYSINFO_ID: 013
SYSTEM INFO REPORT: Originator:

Unable to Initialize Card


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4603 MDHPRDCUT sysinfo description : The TDPC failed during the preliminary phase of the card load, this phase has the purpose to reset the card, configure it and let the TDPC FW start. 1 = Line in the code where the system info has been formatted. 2 = Number of attempts performed to start the TDPC card. 3 = Memt configuration. 4 = Code of the detected error. 5 = Software module where the error occurred. 6 = Software line in the module where the error has been recognized. 7 = Not used. 8 = Not used. 9 = Not used. 10 = Not used. 11 = Not used. 12 = Not used. 13 = Not used. 14 = Not used. 15 = Not used. 16 = Not used. 17 = Not used. 18 = Not used. 19 = Not used. 20 = Not used. 21 = Not used. 22 = Not used. 23 = Not used. 24 = Not used. 25 = Not used. 26 = Not used. 27 = Not used. 28 = Not used. 29 = Not used. 30 = Not used. 31 = Not used. 32 = Not used. ##fine##

666

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

SYSINFO_ID: 014
SYSTEM INFO REPORT: Originator:

Failed Load SW Procedure


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4601 MDHPRDCMC sysinfo description : The load command towards TDPC failed. 1 = Line in the code where the system info has been issued. 2 = TDPC status bits ( low bits ). 3 = TDPC status bits ( high bits ). 4 = Result of the command processing. 5 = Event under processing. 6 = TDPC device handler automa status. 7 = TDPC device handler internal automa sub-status. 8 = Not used. 9 = Not used. 10 = Not used. 11 = Not used. 12 = Not used. 13 = Not used. 14 = Not used. 15 = Not used. 16 = Not used. 17 = Not used. 18 = Not used. 19 = Not used. 20 = Not used. 21 = Not used. 22 = Not used. 23 = Not used. 24 = Not used. 25 = Not used. 26 = Not used. 27 = Not used. 28 = Not used. 29 = Not used. 30 = Not used. 31 = Not used. 32 = Not used. Case of XXXX = 4602 MDHPRDCSD sysinfo description :
A30808-X3247-K240-3-7619 667

Outputs OML:BSC

Base Station Controller

The SW load/data crosscopy failed. The affected card stays out of service and some minutes later another attempt to crosscopy it will be done automatically by the system. 1 = Line in the code where the system info has been issued. 2 = The signal subtype coming from Memory Align Server. 3 = Not used. 4 = Not used. 5 = Not used. 6 = Not used. 7 = Not used. 8 = Not used. 9 = Not used. 10 = Not used. 11 = Not used. 12 = Not used. 13 = Not used. 14 = Not used. 15 = Not used. 16 = Not used. 17 = Not used. 18 = Not used. 19 = Not used. 20 = Not used. 21 = Not used. 22 = Not used. 23 = Not used. 24 = Not used. 25 = Not used. 26 = Not used. 27 = Not used. 28 = Not used. 29 = Not used. 30 = Not used. 31 = Not used. 32 = Not used. ##fine##

668

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

SYSINFO_ID: 015
SYSTEM INFO REPORT: Originator:

Failed Load Patch Procedure


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4502 MDHXXDCEH sysinfo description : This system info is issued when PPCU patch load fails because of one of the following occurrences: a) missing Keep Alive message from Patch Load Server b) negative Load Server answer (possible corruption of loaded patch) 1= 2= Source code line bit mask of Status Manager statuses, reassigned according to the following values: 0x01 = XX_DEPENDENCY 0x02 = XX_FAILED 0x04 = XX_INITIALIZING 0x08 = XX_IN_TEST 0x10 = XX_NOT_INITIALIZED 0x20 = XX_OFFLINE 0x40 = XX_RSVD_FOR_TEST 0x80 = XX_NOT_INIT_ALARMED If this value is equal to 2, a load retry (second attempt) is in progress Current BSC Agent command (if any) Event (0x4 = time-out, 0x1D = Load Server fault) Error code (if a problem was found during restoring operation of DUAM inaccessibility and SW state) Line where the problem (if any) was found Source item identifier Patch type (0 = All Permanent, 1 = All Running, 2 = Single Patch) in Patch Load command Me mnemonic of id associated to patch load Me address[0] of id associated to patch load Low word in cards mask associated to BSC Agent command High word in cards mask associated to BSC Agent command Low word in mask of cards whose command must be processed High word in mask of cards whose command must be processed Command (0xFF if no command) BSC Agent command mode (CSD_MODE_ALL (0), CSD_MODE_PATCH (2)) Me address[0] of id associated to BSC Agent command Me mnemonic of id associated to BSC Agent command Command originator (1 = PPXX DIAGNOSTIC TEST; 2 = BSC AGENT COMMAND) Command result (Load Server answer) Not used. Not used.
669

3= 4= 5= 6= 7= 8= 9= 10 = 11 = 12 = 13 = 14 = 15 = 16 = 17 = 18 = 19 = 20 = 21 = 22 = 23 =

A30808-X3247-K240-3-7619

Outputs OML:BSC

Base Station Controller

24 = 25 = 26 = 27 = 28 = 29 = 30 = 31 = 32 =

Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

Case of XXXX = 4601 MDHPRDCMC sysinfo description : The load patch procedure, for one patch only or for all patches enabled at the bring up, failed. If the SW on the affected card could be considered good, the load patch is re-scheduled, otherwise if the failure occurred during the load of all patches, the affected card is reloaded; in case of single patch load the card is switched. N.B. when the card mnemonic is MPCC only additional info from 1 to 8 are meaningful, for TDPC card are meaningful only info from 9 to 15. 1 = Line in the code where the system info has been issued. 2 = Event handled by the MPCC device handler. 3 = Result of the load patch command. 4 = MPCC device handler automa state. 5 = MPCC device handler automa sub-state. 6 = MPCC card property. 7 = MPCC copy under load. 8 = Request against active or stanby MPCC. 9 = Line in the code where the system info has been issued. 10 = TDPC internal status bits ( low part ). 11 = TDPC internal status bits ( high part ). 12 = Result of the load patch command. 13 = Event handled by the TDPC device handler. 14 = TDPC device handler automa state. 15 = TDPC device handler automa sub-state. 16 = Not used. 17 = Not used. 18 = Not used. 19 = Not used. 20 = Not used. 21 = Not used. 22 = Not used. 23 = Not used. 24 = Not used. 25 = Not used. 26 = Not used. 27 = Not used. 28 = Not used. 29 = Not used. 30 = Not used. 31 = Not used. 32 = Not used. ##fine##

670

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

SYSINFO_ID: 016
SYSTEM INFO REPORT: Originator:

Failed Load Database Procedure


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4601 MDHPRDCMC sysinfo description : The TDPC load database phase failed due to a SW problem or due to a TDPC failure. The system self retry the load database. If the retry is unsuccessful, the TDPC reload is requested. 1 = Line in the code where the system info report has been formatted. 2 = TDPC internal status bits (low part). 3 = TDPC internal status bits (high part). 4 = Result of the load command. 5 = Event handled by the device handler. 6 = TDPC device handler automa state. 7 = Internal TDPC device handler automa sub-state. 8 = Not used. 9 = Not used. 10 = Not used. 11 = Not used. 12 = Not used. 13 = Not used. 14 = Not used. 15 = Not used. 16 = Not used. 17 = Not used. 18 = Not used. 19 = Not used. 20 = Not used. 21 = Not used. 22 = Not used. 23 = Not used. 24 = Not used. 25 = Not used. 26 = Not used. 27 = Not used. 28 = Not used. 29 = Not used. 30 = Not used. 31 = Not used. 32 = Not used. ##fine##

A30808-X3247-K240-3-7619

671

Outputs OML:BSC

Base Station Controller

SYSINFO_ID: 017
SYSTEM INFO REPORT: Originator:

Retry to Schedule Load Procedure


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4601 MDHPRDCMC sysinfo description : The current load procedure failed, because of HW or SW problems or due to a message lost. The sequence is closed and the load command is re-scheduled three times. After these attempts, the affected card is put out of service. 1 = Line in the code where the problem took place. 2 = Event handled by the device handler. 3 = Device handler automa sub-state. 4 = Device handler automa state. 5 = Number of retry perfomed by the device handler. 6 = Card property. 7 = Copy of the card under load. 8 = Load type. 9 = Result of the load sequence. 10 = Not used. 11 = Not used. 12 = Not used. 13 = Not used. 14 = Not used. 15 = Not used. 16 = Not used. 17 = Not used. 18 = Not used. 19 = Not used. 20 = Not used. 21 = Not used. 22 = Not used. 23 = Not used. 24 = Not used. 25 = Not used. 26 = Not used. 27 = Not used. 28 = Not used. 29 = Not used. 30 = Not used. 31 = Not used. 32 = Not used. ##fine##

672

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

SYSINFO_ID: 018
SYSTEM INFO REPORT: Originator:

Corrupted SW on Card
<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:

Case of XXXX = 4502 MDHXXDCEH sysinfo description : This system info is issued when PPCU patch load fails because of one of the following occurrences: a) File System Failed answer coming from Load Server b) Failure of fsdsmGetExeSvr (System Download utility) called by PPCU DH 1 = Source code line 2= bit mask of Status Manager statuses, reassigned according to the following values: 0x01 = XX_DEPENDENCY 0x02 = XX_FAILED 0x04 = XX_INITIALIZING 0x08 = XX_IN_TEST 0x10 = XX_NOT_INITIALIZED 0x20 = XX_OFFLINE 0x40 = XX_RSVD_FOR_TEST 0x80 = XX_NOT_INIT_ALARMED 3 = If this value is equal to 2, a load retry (second attempt) is in progress 4 = Current BSC Agent command (if any) 5 = Event (0x1E = Load Server File System fault) 6 = Error code (if a problem was found during restoring operation of DUAM inaccessibility and SW state) 7 = Line where the problem (if any) was found 8 = Source item identifier 9 = Patch type (0 = All Permanent, 1 = All Running, 2 = Single Patch) in Patch Load command 10 = Me mnemonic of id associated to patch load 11 = Me address[0] of id associated to patch load 12 = Low word in cards mask associated to BSC Agent command 13 = High word in cards mask associated to BSC Agent command 14 = Low word in mask of cards whose command must be processed 15 = High word in mask of cards whose command must be processed 16 = Command (0xFF if no command) 17 = BSC Agent command mode (CSD_MODE_ALL (0), CSD_MODE_PATCH (2)) 18 = Me address[0] of id associated to BSC Agent command 19 = Me mnemonic of id associated to BSC Agent command 20 = Command originator (1 = PPXX DIAGNOSTIC TEST; 2 = BSC AGENT COMMAND)
A30808-X3247-K240-3-7619 673

Outputs OML:BSC

Base Station Controller

21 = 22 = 23 = 24 = 25 = 26 = 27 = 28 = 29 = 30 = 31 = 32 =

Command result (Load Server answer) Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

Case of XXXX = 4604 MDHPRDCSM sysinfo description : This system info is issued when the TDPC device handler receives a DISABLE command during the load single patch procedure. The active TDPC copy is put DISABLED/NOT_INITIALIZED and a switch to the other copy is attempted. 1 = Line in the code where the problem occurred (just before the TDPC switch). 2 = Not used. 3 = Not used. 4 = Not used. 5 = Not used. 6 = Not used. 7 = Not used. 8 = Not used. 9 = Not used. 10 = Not used. 11 = Not used. 12 = Not used. 13 = Not used. 14 = Not used. 15 = Not used. 16 = Not used. 17 = Not used. 18 = Not used. 19 = Not used. 20 = Not used. 21 = Not used. 22 = Not used. 23 = Not used. 24 = Not used. 25 = Not used. 26 = Not used. 27 = Not used. 28 = Not used. 29 = Not used. 30 = Not used. 31 = Not used. 32 = Not used. ##fine##

674

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

SYSINFO_ID: 020
SYSTEM INFO REPORT: Originator:

Intra Processor Link Trace


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4602 MDHPRDCSD sysinfo description : The SW load/data crosscopy failed. The affected card stays out of service and some minutes later another attempt to crosscopy will be done automatically by the system. 1 = Line in the code where the system info report is issued. 2 = The signal subtype coming from the Memory Align Server. 3 = Not used. 4 = Not used. 5 = Not used. 6 = Not used. 7 = Not used. 8 = Not used. 9 = Not used. 10 = Not used. 11 = Not used. 12 = Not used. 13 = Not used. 14 = Not used. 15 = Not used. 16 = Not used. 17 = Not used. 18 = Not used. 19 = Not used. 20 = Not used. 21 = Not used. 22 = Not used. 23 = Not used. 24 = Not used. 25 = Not used. 26 = Not used. 27 = Not used. 28 = Not used. 29 = Not used. 30 = Not used. 31 = Not used. 32 = Not used. ##fine##

A30808-X3247-K240-3-7619

675

Outputs OML:BSC

Base Station Controller

SYSINFO_ID: 021
SYSTEM INFO REPORT: Originator:

Bad SW Version on Board`


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4602 MDHPRDCSD sysinfo description : The software version owned by the Control Load and the one written on the device handler local database are different. If the mismatch is between Control load and the active MPCC copy then an immediate reload is performed, otherwise if the problem is located on the standby MPCC copy or one of the TDPC cards, the affected card is put DISABLED/NOT_INITIALIZED. A self recover will start few minutes later. N.B.: if the affected card is TDPC, the first additional info is the subtype of the received message, the second additional info is the TDPC status owned by the device handler and all other info are meaningless. 1 = Line in the code where the system info is called. 2 = Mnemonic intentifier of the affected card or input subtype field. 3 = Menmonic address of the affected card or TDPC status bits.. 4 = ASCII coded value of software version to load (high byte) and stored version (low byte). 5 = ASCII coded value of software version to load (high byte) and stored version (low byte). 6 = ASCII coded value of software version to load (high byte) and stored version (low byte). 7 = ASCII coded value of software version to load (high byte) and stored version (low byte). 8 = ASCII coded value of software version to load (high byte) and stored version (low byte). 9 = ASCII coded value of software version to load (high byte) and stored version (low byte). 10 = ASCII coded value of software version to load (high byte) and stored version (low byte). 11 = ASCII coded value of software version to load (high byte) and stored version (low byte). 12 = ASCII coded value of software version to load (high byte) and stored version (low byte). 13 = ASCII coded value of software version to load (high byte) and stored version (low byte). 14 = ASCII coded value of software version to load (high byte) and stored version (low byte). 15 = ASCII coded value of software version to load (high byte) and stored version (low byte). 16 = ASCII coded value of software version to load (high byte) and stored version (low byte). 17 = ASCII coded value of software version to load (high byte) and stored version (low byte). 18 = ASCII coded value of software version to load (high byte) and stored version (low byte). 19 = ASCII coded value of software version to load (high byte) and stored version (low byte). 20 = ASCII coded value of software version to load (high byte) and stored version (low byte). 21 = ASCII coded value of software version to load (high byte) and stored version (low byte). 22 = ASCII coded value of software version to load (high byte) and stored version (low byte). 23 = ASCII coded value of software version to load (high byte) and stored version (low byte). 24 = ASCII coded value of software version to load (high byte) and stored version (low byte). 25 = ASCII coded value of software version to load (high byte) and stored version (low byte). 26 = ASCII coded value of software version to load (high byte) and stored version (low byte). 27 = ASCII coded value of software version to load (high byte) and stored version (low byte). 28 = ASCII coded value of software version to load (high byte) and stored version (low byte). 29 = ASCII coded value of software version to load (high byte) and stored version (low byte). 30 = ASCII coded value of software version to load (high byte) and stored version (low byte). 31 = Not used.
676 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

32 =

Not used.

Case of XXXX = 4604 MDHPRDCSM sysinfo description : This system info is issued every time one of the MPCC or TDPC cards must be loaded, before going back to service; for example, when the LOCK command is issued and the card is reset or upon the ENABLE (e. g. after a PERFTEST command) and UNLOCK commands, when the card stores an old or invalid load . The status of the affected card after this notification will be DISABLED/NOT_INITIALIZED. 1 = Line in the code where the system info is called. 2 = Mnemonic identifier of the affected card. 3 = Menmonic address of the affected card. 4 = ASCII coded value of software version to load (high byte) and stored version (low byte). 5 = ASCII coded value of software version to load (high byte) and stored version (low byte). 6 = ASCII coded value of software version to load (high byte) and stored version (low byte). 7 = ASCII coded value of software version to load (high byte) and stored version (low byte). 8 = ASCII coded value of software version to load (high byte) and stored version (low byte). 9 = ASCII coded value of software version to load (high byte) and stored version (low byte). 10 = ASCII coded value of software version to load (high byte) and stored version (low byte). 11 = ASCII coded value of software version to load (high byte) and stored version (low byte). 12 = ASCII coded value of software version to load (high byte) and stored version (low byte). 13 = ASCII coded value of software version to load (high byte) and stored version (low byte). 14 = ASCII coded value of software version to load (high byte) and stored version (low byte). 15 = ASCII coded value of software version to load (high byte) and stored version (low byte). 16 = ASCII coded value of software version to load (high byte) and stored version (low byte). 17 = ASCII coded value of software version to load (high byte) and stored version (low byte). 18 = ASCII coded value of software version to load (high byte) and stored version (low byte). 19 = ASCII coded value of software version to load (high byte) and stored version (low byte). 20 = ASCII coded value of software version to load (high byte) and stored version (low byte). 21 = ASCII coded value of software version to load (high byte) and stored version (low byte). 22 = ASCII coded value of software version to load (high byte) and stored version (low byte). 23 = ASCII coded value of software version to load (high byte) and stored version (low byte). 24 = ASCII coded value of software version to load (high byte) and stored version (low byte). 25 = ASCII coded value of software version to load (high byte) and stored version (low byte). 26 = ASCII coded value of software version to load (high byte) and stored version (low byte). 27 = ASCII coded value of software version to load (high byte) and stored version (low byte). 28 = ASCII coded value of software version to load (high byte) and stored version (low byte). 29 = ASCII coded value of software version to load (high byte) and stored version (low byte). 30 = ASCII coded value of software version to load (high byte) and stored version (low byte). 31 = Not used. 32 = Not used. ##fine##

A30808-X3247-K240-3-7619

677

Outputs OML:BSC

Base Station Controller

SYSINFO_ID: 022
SYSTEM INFO REPORT: Originator:

MPCC Log Internal Registers


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4603 MDHPRDCUT sysinfo description : This sysrtem info is isseud every time a diagnostic of one ME2M,MEMT,PWRD,MPCC card fails. It has the purpose to output all useful information about the hardware state at the diagnostic time. 1 = Line in the code where this system info is issued. 2 = MPCC alarm register. 3 = MPCC control point register. 4 = MPCC mask register. 5 = MPCC sense point register. 6 = MPCC GA alarm register. 7 = MPCC GA external sense point register. 8 = MPCC GA external/internal control point register. 9 = MPCC GA trap register 2 register. 10 = MPCC GA trap register 1 register. 11 = MPCC GA data trap register. 12 = MPCC GA loop back register. 13 = PIC master mask & in-service register. 14 = PIC slave mask & in-service register 15 = Not used. 16 = Not used. 17 = Not used. 18 = Not used. 19 = Not used. 20 = Not used. 21 = Not used. 22 = Not used. 23 = Not used. 24 = Not used. 25 = Not used. 26 = Not used. 27 = Not used. 28 = Not used. 29 = Not used. 30 = Not used. 31 = Not used. 32 = Not used. ##fine##

678

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

SYSINFO_ID: 023
SYSTEM INFO REPORT: Originator:

MPCC Log PCS 0


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4603 MDHPRDCUT sysinfo description : This system info is issued when the diagnostic of the ME2M or MEMT card COPY 0 fails. It contains additional info that could help in failure analysis. 1 = MEMT alarm register + ME2M alarm register. 2 = MEMT + ME2M small page protection register. 3 = MEMT + ME2M small page selection register. 4 = MEMT & ME2M large page selection register. 5 = ME2M large page protection register. 6 = MEMT mask and protection register. 7 = Not used. 8 = Not used. 9 = Not used. 10 = Not used. 11 = Not used. 12 = Not used. 13 = Not used. 14 = Not used. 15 = Not used. 16 = Not used. 17 = Not used. 18 = Not used. 19 = Not used. 20 = Not used. 21 = Not used. 22 = Not used. 23 = Not used. 24 = Not used. 25 = Not used. 26 = Not used. 27 = Not used. 28 = Not used. 29 = Not used. 30 = Not used. 31 = Not used. 32 = Not used. ##fine##

A30808-X3247-K240-3-7619

679

Outputs OML:BSC

Base Station Controller

SYSINFO_ID: 024
SYSTEM INFO REPORT: Originator:

MPCC Log PCS 1


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4603 MDHPRDCUT sysinfo description : This system info is issued when the diagnostic of the ME2M or MEMT card COPY 1 fails. It contains additional info that could help in failure analysis. 1 = MEMT alarm register + ME2M alarm register. 2 = MEMT + ME2M small page protection register. 3 = MEMT + ME2M small page selection register. 4 = MEMT & ME2M large page selection register. 5 = ME2M large page protection register. 6 = MEMT mask and protection register. 7 = Not used. 8 = Not used. 9 = Not used. 10 = Not used. 11 = Not used. 12 = Not used. 13 = Not used. 14 = Not used. 15 = Not used. 16 = Not used. 17 = Not used. 18 = Not used. 19 = Not used. 20 = Not used. 21 = Not used. 22 = Not used. 23 = Not used. 24 = Not used. 25 = Not used. 26 = Not used. 27 = Not used. 28 = Not used. 29 = Not used. 30 = Not used. 31 = Not used. 32 = Not used. ##fine##

680

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

SYSINFO_ID: 025
SYSTEM INFO REPORT: Originator:

MEMT Contents Lost


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4601 MDHPRDCMC sysinfo description : The system info is issued to point out that the data stored on the MEMT card, up from this point, are no more valid. This is done before the TDPC code load and before the TDPC database load. The problem that leads to the TDPC reload could be retrieved from the additional info. 1 = Line in the code where the MEMT data are declared lost. 2 = Software module that started the TDPC reload. 3 = Line in the sotware module where the reload is called. 4 = Type of load to perform, complete or database only. 5 = Not used. 6 = Not used. 7 = Not used. 8 = Not used. 9 = Not used. 10 = Not used. 11 = Not used. 12 = Not used. 13 = Not used. 14 = Not used. 15 = Not used. 16 = Not used. 17 = Not used. 18 = Not used. 19 = Not used. 20 = Not used. 21 = Not used. 22 = Not used. 23 = Not used. 24 = Not used. 25 = Not used. 26 = Not used. 27 = Not used. 28 = Not used. 29 = Not used. 30 = Not used. 31 = Not used. 32 = Not used.

A30808-X3247-K240-3-7619

681

Outputs OML:BSC

Base Station Controller

Case of XXXX = 4605 MDHPRININ sysinfo description : The MEMT init sequence failed during the dedicated time, while performing a full init. The data on the MEMT card are not reliable. 1 = Line in the code where the MEMT data are declared lost. 2 = Software module where the initialization failed. 3 = Line in the sotware module where the reload is called. 4 = Type of the occured failure. 5 = Not used. 6 = Not used. 7 = Not used. 8 = Not used. 9 = Not used. 10 = Not used. 11 = Not used. 12 = Not used. 13 = Not used. 14 = Not used. 15 = Not used. 16 = Not used. 17 = Not used. 18 = Not used. 19 = Not used. 20 = Not used. 21 = Not used. 22 = Not used. 23 = Not used. 24 = Not used. 25 = Not used. 26 = Not used. 27 = Not used. 28 = Not used. 29 = Not used. 30 = Not used. 31 = Not used. 32 = Not used. ##fine##

682

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

SYSINFO_ID: 026
SYSTEM INFO REPORT: Originator:

Audit Message Out of Sequence


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4600 MDHPRDCDE sysinfo description : The reply received by the MPCC from the active TDPC is correct, so the TDPC card is correctly running, but the message counter that flag the corrispondence between request and answer is not aligned. This sys info notify the mismatch but no recovery action is taken. From this point the counters are realigned. 1 = Line in the code where the system info is issued. 2 = Current time when the mismatch is detected. 3 = TDPC number from active TDPC 4 = Last init performed by the TDPC 5 = Nmi counter[0] from active TDPC. 6 = Nmi counter[1] from active TDPC. 7 = Received answer counter. 8 = Sent request counter. 9 = TDPC status internal to the device handler. 10 = Not used. 11 = Not used 12 = Not used 13 = Not used 14 = Not used 15 = Not used 16 = Not used 17 = Not used 18 = Not used 19 = Not used 20 = Not used 21 = Not used 22 = Not used 23 = Not used 24 = Not used 25 = Not used 26 = Not used 27 = Not used 28 = Not used 29 = Not used 30 = Not used 31 = Not used 32 = Not used ##fine##

A30808-X3247-K240-3-7619

683

Outputs OML:BSC

Base Station Controller

SYSINFO_ID: 027
SYSTEM INFO REPORT: Originator:

No Response to Message Audit


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4606 MDHPRDCSA sysinfo description : This System Info can be issued in one of the following cases: 1) when the TDPC fails to answer to the inter processor audit with MPCC; 2) when the standby TDPC does not answer to the audit request from the active one; 3) when the standby MPCC does not answer to the audit request from the active one. 1 = Line in the code where the system info is issued. 2 = Sent request counter. 3 = Received answer counter. 4 = Not used. 5 = Not used. 6 = Not used. 7 = Not used. 8 = Not used. 9 = Not used. 10 = Not used. 11 = Not used. 12 = Not used. 13 = Not used. 14 = Not used. 15 = Not used. 16 = Not used. 17 = Not used. 18 = Not used. 19 = Not used. 20 = Not used. 21 = Not used. 22 = Not used. 23 = Not used. 24 = Not used. 25 = Not used. 26 = Not used. 27 = Not used. 28 = Not used. 29 = Not used. 30 = Not used. 31 = Not used. 32 = Not used. ##fine##
684 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

SYSINFO_ID: 028
SYSTEM INFO REPORT: Originator:

TDPC Control Lost


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4606 MDHPRDCSA sysinfo description : This system information is issued just before the system starts the full initialization when the threshold of no response to message audit is crossed. The full is the attempt to get again the control of the TDPC card. 1 = Line in the code where the system info is issued. 2 = TDPC internal status bits ( low part ). 3 = TDPC internal status bits ( high part ). 4 = Error cause. 5 = Old active TDPC copy. 6 = Software module where the error took place. 7 = Line in the software module where the error has been recognized. 8 = Not used. 9 = Not used. 10 = Not used. 11 = Not used. 12 = Not used. 13 = Not used. 14 = Not used. 15 = Not used. 16 = Not used. 17 = Not used. 18 = Not used. 19 = Not used. 20 = Not used. 21 = Not used. 22 = Not used. 23 = Not used. 24 = Not used. 25 = Not used. 26 = Not used. 27 = Not used. 28 = Not used. 29 = Not used. 30 = Not used. 31 = Not used. 32 = Not used. ##fine##

A30808-X3247-K240-3-7619

685

Outputs OML:BSC

Base Station Controller

SYSINFO_ID: 029
SYSTEM INFO REPORT: Originator:

Retry to Align MEMT Ram


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4601 MDHPRDCMC sysinfo description : The alignment of the standby MEMT card failed, due to timeout expiration. One immediate retry is performed in order to put in service the card. 1 = Line in the code where the failure has been acknowledged. 2 = Event handled by the device handler. 3 = MEMT status internal to the device handler. 4 = Not used. 5 = Not used. 6 = Not used. 7 = Not used. 8 = Not used. 9 = Not used. 10 = Not used. 11 = Not used. 12 = Not used. 13 = Not used. 14 = Not used. 15 = Not used. 16 = Not used. 17 = Not used. 18 = Not used. 19 = Not used. 20 = Not used. 21 = Not used. 22 = Not used. 23 = Not used. 24 = Not used. 25 = Not used. 26 = Not used. 27 = Not used. 28 = Not used. 29 = Not used. 30 = Not used. 31 = Not used. 32 = Not used. ##fine##

686

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

SYSINFO_ID: 030
SYSTEM INFO REPORT: Originator:

NMI Os Trap
<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4608 MDHPRDDNH sysinfo description : This system info is issued by the NMI handler routine when a fatal error is detected. After this kind of error occurrs the affected MPCC card is switched. 1 = First entry of the OS callstack ( low portion ). 2 = First entry of the OS callstack ( high portion ). 3 = Second entry of the OS callstack ( low portion ). 4 = Second entry of the OS callstack ( high portion ). 5 = Third entry of the OS callstack ( low portion ). 6 = Third entry of the OS callstack ( high portion ). 7 = Not used. 8 = Not used. 9 = Not used. 10 = Not used. 11 = Not used. 12 = Not used. 13 = Not used. 14 = Not used. 15 = Not used. 16 = Not used. 17 = Not used. 18 = Not used. 19 = Not used. 20 = Not used. 21 = Not used. 22 = Not used. 23 = Not used. 24 = Not used. 25 = Not used. 26 = Not used. 27 = Not used. 28 = Not used. 29 = Not used. 30 = Not used. 31 = Not used. 32 = Not used. ##fine##

A30808-X3247-K240-3-7619

687

Outputs OML:BSC

Base Station Controller

SYSINFO_ID: 031
SYSTEM INFO REPORT: Originator:

BTS no BCCH Available Info


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4700 TDHBFCFMN sysinfo description : This notification occurs when the BTSM DH detects the loss of the BCCH channel. 1 = module line when the Error Collector call is. 2 = BTSM number 3 = BTS relative number 4 = BTSM software release 5 = High BAR condition (DHBFI.H): BAR_NO_BTSM 0x1 btsm disabled or locked BAR_NO_BTS 0x2 bts disabled or locked BAR_NO_TRX 0x4 no one trx enabled-unlocked BAR_NO_BCCH 0x8 no bcch currently available BAR_FAILED_BCCH 0x10 bcch trx locked or disabled dep abis BAR_BCCH_DSBL 0x20 keep barred the cell as long as bcch is not enable BAR_NO_SDCCH 0x40 no sdcch currently available BAR_FAILED_SDCCH 0x80 last sdcch trx locked or disabled dep abis BAR_NO_TCH 0x100 no traffic channel available BAR_TCH_DSBL 0x200 keep barred the cell at least a channel is enabled BAR_FAILED_HOP 0x400 hopping trx locked of disable dep abis BAR_FAILED_CBCH 0x800 cbch trx locked or disabled dep abis BAR_STRTM 0x1000 starting time procedure evolving BAR_ENABLE_HOP 0x2000 restart of hopping procedure BAR_BCCH_FREQ 0x4000 bcch frequency change procedure 6 = Low BAR condition (DHBFI.H): BAR_NO_BTSM 0x1 btsm disabled or locked BAR_NO_BTS 0x2 bts disabled or locked BAR_NO_TRX 0x4 no one trx enabled-unlocked BAR_NO_BCCH 0x8 no bcch currently available BAR_FAILED_BCCH 0x10 bcch trx locked or disabled dep abis BAR_BCCH_DSBL 0x20 keep barred the cell as long as bcch is not enable BAR_NO_SDCCH 0x40 no sdcch currently available BAR_FAILED_SDCCH 0x80 last sdcch trx locked or disabled dep abis BAR_NO_TCH 0x100 no traffic channel available BAR_TCH_DSBL 0x200 keep barred the cell at least a channel is enabled BAR_FAILED_HOP 0x400 hopping trx locked of disable dep abis BAR_FAILED_CBCH 0x800 cbch trx locked or disabled dep abis BAR_STRTM 0x1000 starting time procedure evolving BAR_ENABLE_HOP 0x2000 restart of hopping procedure BAR_BCCH_FREQ 0x4000 bcch frequency change procedure
688 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

7=

8=

9= 10 = 11 = 12 = 13 = 14 = 15 = 16 = 17 = 18 =

19 = 20 = 21 = 22 = 23 = 24 = 25 = 26 = 27 = 28 = 29 = 30 = 31 = 32 =

Internal high error code: EC_BCCH_OUTAGE 0x1 EC_NO_BCCH 0x2 EC_FAILED_HOP 0x4 EC_NO_TCH 0x8 EC_NO_SDCCH 0x10 EC_NO_CBCH 0x20 EC_DEGRADED_BARR 0x40 EC_DEGRADED_DIV 0x80 EC_CRIT_THR 0x400 EC_MAJOR_THR 0x200 EC_MINOR_THR 0x100 EC_RESTART_HOP 0x800 EC_BCCH_FREQ 0x1000 Internal low error code: EC_BCCH_OUTAGE 0x1 EC_NO_BCCH 0x2 EC_FAILED_HOP 0x4 EC_NO_TCH 0x8 EC_NO_SDCCH 0x10 EC_NO_CBCH 0x20 EC_DEGRADED_BARR 0x40 EC_DEGRADED_DIV 0x80 EC_CRIT_THR 0x400 EC_MAJOR_THR 0x200 EC_MINOR_THR 0x100 EC_RESTART_HOP 0x800 EC_BCCH_FREQ 0x1000 BCCH TRX absolute number SCBCH TRX absolute number number of SDCCH channels number of TCH channels IsHopp status value (TRUE/FALSE) AbisHopp value (TRUE/FALSE) High AbisHopp time stamp Low AbisHopp time stamp BTS abis operational state (iope): ENABLED (0x01) DISABLED (0x02) BTS abis availability status (iavlb) DEPENDENCY (0x05) DEGRADED (0x06) NULL (0xFF) Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used

bts degraded for bar causes; bts degraded for diversity

bts degraded for bar causes; bts degraded for diversity

A30808-X3247-K240-3-7619

689

Outputs OML:BSC

Base Station Controller

##fine##

690

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

SYSINFO_ID: 032
SYSTEM INFO REPORT: Originator:

BTS Failed Hopping System Info


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4700 TDHBFCFMN sysinfo description : This notification occurs when the BTSM DH detects a failure on a TRX and a frequency redefinition is performed. 1 = module line when the Error Collector call is. 2 = BTSM number 3 = BTS relative number 4 = BTSM software release 5 = High BAR condition (DHBFI.H): BAR_NO_BTSM 0x1 btsm disabled or locked BAR_NO_BTS 0x2 bts disabled or locked BAR_NO_TRX 0x4 no one trx enabled-unlocked BAR_NO_BCCH 0x8 no bcch currently available BAR_FAILED_BCCH 0x10 bcch trx locked or disabled dep abis BAR_BCCH_DSBL 0x20 keep barred the cell as long as bcch is not enable BAR_NO_SDCCH 0x40 no sdcch currently available BAR_FAILED_SDCCH 0x80 last sdcch trx locked or disabled dep abis BAR_NO_TCH 0x100 no traffic channel available BAR_TCH_DSBL 0x200 keep barred the cell at least a channel is enabled BAR_FAILED_HOP 0x400 hopping trx locked of disable dep abis BAR_FAILED_CBCH 0x800 cbch trx locked or disabled dep abis BAR_STRTM 0x1000 starting time procedure evolving BAR_ENABLE_HOP 0x2000 restart of hopping procedure BAR_BCCH_FREQ 0x4000 bcch frequency change procedure 6 = Low BAR condition (DHBFI.H): BAR_NO_BTSM 0x1 btsm disabled or locked BAR_NO_BTS 0x2 bts disabled or locked BAR_NO_TRX 0x4 no one trx enabled-unlocked BAR_NO_BCCH 0x8 no bcch currently available BAR_FAILED_BCCH 0x10 bcch trx locked or disabled dep abis BAR_BCCH_DSBL 0x20 keep barred the cell as long as bcch is not enable BAR_NO_SDCCH 0x40 no sdcch currently available BAR_FAILED_SDCCH 0x80 last sdcch trx locked or disabled dep abis BAR_NO_TCH 0x100 no traffic channel available BAR_TCH_DSBL 0x200 keep barred the cell at least a channel is enabled BAR_FAILED_HOP 0x400 hopping trx locked of disable dep abis BAR_FAILED_CBCH 0x800 cbch trx locked or disabled dep abis BAR_STRTM 0x1000 starting time procedure evolving BAR_ENABLE_HOP 0x2000 restart of hopping procedure
A30808-X3247-K240-3-7619 691

Outputs OML:BSC

Base Station Controller

7=

8=

9= 10 = 11 = 12 = 13 = 14 = 15 = 16 = 17 = 18 =

19 = 20 = 21 = 22 = 23 = 24 = 25 = 26 = 27 = 28 = 29 = 30 = 31 =
692

BAR_BCCH_FREQ 0x4000 Internal high error code: EC_BCCH_OUTAGE 0x1 EC_NO_BCCH 0x2 EC_FAILED_HOP 0x4 EC_NO_TCH 0x8 EC_NO_SDCCH 0x10 EC_NO_CBCH 0x20 EC_DEGRADED_BARR 0x40 EC_DEGRADED_DIV 0x80 EC_CRIT_THR 0x400 EC_MAJOR_THR 0x200 EC_MINOR_THR 0x100 EC_RESTART_HOP 0x800 EC_BCCH_FREQ 0x1000 Internal low error code: EC_BCCH_OUTAGE 0x1 EC_NO_BCCH 0x2 EC_FAILED_HOP 0x4 EC_NO_TCH 0x8 EC_NO_SDCCH 0x10 EC_NO_CBCH 0x20 EC_DEGRADED_BARR 0x40 EC_DEGRADED_DIV 0x80 EC_CRIT_THR 0x400 EC_MAJOR_THR 0x200 EC_MINOR_THR 0x100 EC_RESTART_HOP 0x800 EC_BCCH_FREQ 0x1000 BCCH TRX absolute number SCBCH TRX absolute number number of SDCCH channels number of TCH channels IsHopp status value (TRUE/FALSE) AbisHopp value (TRUE/FALSE) High AbisHopp time stamp Low AbisHopp time stamp BTS abis operational state (iope): ENABLED (0x01) DISABLED (0x02) BTS abis availability status (iavlb) DEPENDENCY (0x05) DEGRADED (0x06) NULL (0xFF) Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used

bcch frequency change procedure

bts degraded for bar causes; bts degraded for diversity

bts degraded for bar causes; bts degraded for diversity

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

32 = Not used ##fine##

A30808-X3247-K240-3-7619

693

Outputs OML:BSC

Base Station Controller

SYSINFO_ID: 033
SYSTEM INFO REPORT: Originator:

BTS no CBCH Available Info


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4700 TDHBFCFMN sysinfo description : This notification occurs when the BTSM DH detects the loss of the COMMON BROADCAST channel. 1 = module line when the Error Collector call is. 2 = BTSM number 3 = BTS relative number 4 = BTSM software release 5 = High BAR condition (DHBFI.H): BAR_NO_BTSM 0x1 btsm disabled or locked BAR_NO_BTS 0x2 bts disabled or locked BAR_NO_TRX 0x4 no one trx enabled-unlocked BAR_NO_BCCH 0x8 no bcch currently available BAR_FAILED_BCCH 0x10 bcch trx locked or disabled dep abis BAR_BCCH_DSBL 0x20 keep barred the cell as long as bcch is not enable BAR_NO_SDCCH 0x40 no sdcch currently available BAR_FAILED_SDCCH 0x80 last sdcch trx locked or disabled dep abis BAR_NO_TCH 0x100 no traffic channel available BAR_TCH_DSBL 0x200 keep barred the cell at least a channel is enabled BAR_FAILED_HOP 0x400 hopping trx locked of disable dep abis BAR_FAILED_CBCH 0x800 cbch trx locked or disabled dep abis BAR_STRTM 0x1000 starting time procedure evolving BAR_ENABLE_HOP 0x2000 restart of hopping procedure BAR_BCCH_FREQ 0x4000 bcch frequency change procedure 6 = Low BAR condition (DHBFI.H): BAR_NO_BTSM 0x1 btsm disabled or locked BAR_NO_BTS 0x2 bts disabled or locked BAR_NO_TRX 0x4 no one trx enabled-unlocked BAR_NO_BCCH 0x8 no bcch currently available BAR_FAILED_BCCH 0x10 bcch trx locked or disabled dep abis BAR_BCCH_DSBL 0x20 keep barred the cell as long as bcch is not enable BAR_NO_SDCCH 0x40 no sdcch currently available BAR_FAILED_SDCCH 0x80 last sdcch trx locked or disabled dep abis BAR_NO_TCH 0x100 no traffic channel available BAR_TCH_DSBL 0x200 keep barred the cell at least a channel is enabled BAR_FAILED_HOP 0x400 hopping trx locked of disable dep abis BAR_FAILED_CBCH 0x800 cbch trx locked or disabled dep abis BAR_STRTM 0x1000 starting time procedure evolving BAR_ENABLE_HOP 0x2000 restart of hopping procedure BAR_BCCH_FREQ 0x4000 bcch frequency change procedure
694 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

7=

8=

9= 10 = 11 = 12 = 13 = 14 = 15 = 16 = 17 = 18 =

19 = 20 = 21 = 22 = 23 = 24 = 25 = 26 = 27 = 28 = 29 = 30 = 31 = 32 =

Internal high error code: EC_BCCH_OUTAGE 0x1 EC_NO_BCCH 0x2 EC_FAILED_HOP 0x4 EC_NO_TCH 0x8 EC_NO_SDCCH 0x10 EC_NO_CBCH 0x20 EC_DEGRADED_BARR 0x40 EC_DEGRADED_DIV 0x80 EC_CRIT_THR 0x400 EC_MAJOR_THR 0x200 EC_MINOR_THR 0x100 EC_RESTART_HOP 0x800 EC_BCCH_FREQ 0x1000 Internal low error code: EC_BCCH_OUTAGE 0x1 EC_NO_BCCH 0x2 EC_FAILED_HOP 0x4 EC_NO_TCH 0x8 EC_NO_SDCCH 0x10 EC_NO_CBCH 0x20 EC_DEGRADED_BARR 0x40 EC_DEGRADED_DIV 0x80 EC_CRIT_THR 0x400 EC_MAJOR_THR 0x200 EC_MINOR_THR 0x100 EC_RESTART_HOP 0x800 EC_BCCH_FREQ 0x1000 BCCH TRX absolute number SCBCH TRX absolute number number of SDCCH channels number of TCH channels IsHopp status value (TRUE/FALSE) AbisHopp value (TRUE/FALSE) High AbisHopp time stamp Low AbisHopp time stamp BTS abis operational state (iope): ENABLED (0x01) DISABLED (0x02) BTS abis availability status (iavlb) DEPENDENCY (0x05) DEGRADED (0x06) NULL (0xFF) Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used

bts degraded for bar causes; bts degraded for diversity

bts degraded for bar causes; bts degraded for diversity

A30808-X3247-K240-3-7619

695

Outputs OML:BSC

Base Station Controller

##fine##

696

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

SYSINFO_ID: 034
SYSTEM INFO REPORT: Originator:

BTS no SDCCH Available Info


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4700 TDHBFCFMN sysinfo description : This notification occurs when the BTSM DH detects the loss of the SDCCH channel. 1 = module line when the Error Collector call is. 2 = BTSM number 3 = BTS relative number 4 = BTSM software release 5 = High BAR condition (DHBFI.H): BAR_NO_BTSM 0x1 btsm disabled or locked BAR_NO_BTS 0x2 bts disabled or locked BAR_NO_TRX 0x4 no one trx enabled-unlocked BAR_NO_BCCH 0x8 no bcch currently available BAR_FAILED_BCCH 0x10 bcch trx locked or disabled dep abis BAR_BCCH_DSBL 0x20 keep barred the cell as long as bcch is not enable BAR_NO_SDCCH 0x40 no sdcch currently available BAR_FAILED_SDCCH 0x80 last sdcch trx locked or disabled dep abis BAR_NO_TCH 0x100 no traffic channel available BAR_TCH_DSBL 0x200 keep barred the cell at least a channel is enabled BAR_FAILED_HOP 0x400 hopping trx locked of disable dep abis BAR_FAILED_CBCH 0x800 cbch trx locked or disabled dep abis BAR_STRTM 0x1000 starting time procedure evolving BAR_ENABLE_HOP 0x2000 restart of hopping procedure BAR_BCCH_FREQ 0x4000 bcch frequency change procedure 6 = Low BAR condition (DHBFI.H): BAR_NO_BTSM 0x1 btsm disabled or locked BAR_NO_BTS 0x2 bts disabled or locked BAR_NO_TRX 0x4 no one trx enabled-unlocked BAR_NO_BCCH 0x8 no bcch currently available BAR_FAILED_BCCH 0x10 bcch trx locked or disabled dep abis BAR_BCCH_DSBL 0x20 keep barred the cell as long as bcch is not enable BAR_NO_SDCCH 0x40 no sdcch currently available BAR_FAILED_SDCCH 0x80 last sdcch trx locked or disabled dep abis BAR_NO_TCH 0x100 no traffic channel available BAR_TCH_DSBL 0x200 keep barred the cell at least a channel is enabled BAR_FAILED_HOP 0x400 hopping trx locked of disable dep abis BAR_FAILED_CBCH 0x800 cbch trx locked or disabled dep abis BAR_STRTM 0x1000 starting time procedure evolving BAR_ENABLE_HOP 0x2000 restart of hopping procedure BAR_BCCH_FREQ 0x4000 bcch frequency change procedure
A30808-X3247-K240-3-7619 697

Outputs OML:BSC

Base Station Controller

7=

8=

9= 10 = 11 = 12 = 13 = 14 = 15 = 16 = 17 = 18 =

19 = 20 = 21 = 22 = 23 = 24 = 25 = 26 = 27 = 28 = 29 = 30 = 31 = 32 =
698

Internal high error code: EC_BCCH_OUTAGE 0x1 EC_NO_BCCH 0x2 EC_FAILED_HOP 0x4 EC_NO_TCH 0x8 EC_NO_SDCCH 0x10 EC_NO_CBCH 0x20 EC_DEGRADED_BARR 0x40 EC_DEGRADED_DIV 0x80 EC_CRIT_THR 0x400 EC_MAJOR_THR 0x200 EC_MINOR_THR 0x100 EC_RESTART_HOP 0x800 EC_BCCH_FREQ 0x1000 Internal low error code: EC_BCCH_OUTAGE 0x1 EC_NO_BCCH 0x2 EC_FAILED_HOP 0x4 EC_NO_TCH 0x8 EC_NO_SDCCH 0x10 EC_NO_CBCH 0x20 EC_DEGRADED_BARR 0x40 EC_DEGRADED_DIV 0x80 EC_CRIT_THR 0x400 EC_MAJOR_THR 0x200 EC_MINOR_THR 0x100 EC_RESTART_HOP 0x800 EC_BCCH_FREQ 0x1000 BCCH TRX absolute number SCBCH TRX absolute number number of SDCCH channels number of TCH channels IsHopp status value (TRUE/FALSE) AbisHopp value (TRUE/FALSE) High AbisHopp time stamp Low AbisHopp time stamp BTS abis operational state (iope): ENABLED (0x01) DISABLED (0x02) BTS abis availability status (iavlb) DEPENDENCY (0x05) DEGRADED (0x06) NULL (0xFF) Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used

bts degraded for bar causes; bts degraded for diversity

bts degraded for bar causes; bts degraded for diversity

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

##fine##

A30808-X3247-K240-3-7619

699

Outputs OML:BSC

Base Station Controller

SYSINFO_ID: 035
SYSTEM INFO REPORT: Originator:

BTS no TCH Available Info


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4700 TDHBFCFMN sysinfo description : This notification occurs when the BTSM DH detects the unavailability of all the TRAFFIC channels due to a failure or a LOCK command. 1 = module line when the Error Collector call is. 2 = BTSM number 3 = BTS relative number 4 = BTSM software release 5 = High BAR condition (DHBFI.H): BAR_NO_BTSM 0x1 btsm disabled or locked BAR_NO_BTS 0x2 bts disabled or locked BAR_NO_TRX 0x4 no one trx enabled-unlocked BAR_NO_BCCH 0x8 no bcch currently available BAR_FAILED_BCCH 0x10 bcch trx locked or disabled dep abis BAR_BCCH_DSBL 0x20 keep barred the cell as long as bcch is not enable BAR_NO_SDCCH 0x40 no sdcch currently available BAR_FAILED_SDCCH 0x80 last sdcch trx locked or disabled dep abis BAR_NO_TCH 0x100 no traffic channel available BAR_TCH_DSBL 0x200 keep barred the cell at least a channel is enabled BAR_FAILED_HOP 0x400 hopping trx locked of disable dep abis BAR_FAILED_CBCH 0x800 cbch trx locked or disabled dep abis BAR_STRTM 0x1000 starting time procedure evolving BAR_ENABLE_HOP 0x2000 restart of hopping procedure BAR_BCCH_FREQ 0x4000 bcch frequency change procedure 6 = Low BAR condition (DHBFI.H): BAR_NO_BTSM 0x1 btsm disabled or locked BAR_NO_BTS 0x2 bts disabled or locked BAR_NO_TRX 0x4 no one trx enabled-unlocked BAR_NO_BCCH 0x8 no bcch currently available BAR_FAILED_BCCH 0x10 bcch trx locked or disabled dep abis BAR_BCCH_DSBL 0x20 keep barred the cell as long as bcch is not enable BAR_NO_SDCCH 0x40 no sdcch currently available BAR_FAILED_SDCCH 0x80 last sdcch trx locked or disabled dep abis BAR_NO_TCH 0x100 no traffic channel available BAR_TCH_DSBL 0x200 keep barred the cell at least a channel is enabled BAR_FAILED_HOP 0x400 hopping trx locked of disable dep abis BAR_FAILED_CBCH 0x800 cbch trx locked or disabled dep abis BAR_STRTM 0x1000 starting time procedure evolving BAR_ENABLE_HOP 0x2000 restart of hopping procedure
700 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

7=

8=

9= 10 = 11 = 12 = 13 = 14 = 15 = 16 = 17 = 18 =

19 = 20 = 21 = 22 = 23 = 24 = 25 = 26 = 27 = 28 = 29 = 30 = 31 =

BAR_BCCH_FREQ 0x4000 Internal high error code: EC_BCCH_OUTAGE 0x1 EC_NO_BCCH 0x2 EC_FAILED_HOP 0x4 EC_NO_TCH 0x8 EC_NO_SDCCH 0x10 EC_NO_CBCH 0x20 EC_DEGRADED_BARR 0x40 EC_DEGRADED_DIV 0x80 EC_CRIT_THR 0x400 EC_MAJOR_THR 0x200 EC_MINOR_THR 0x100 EC_RESTART_HOP 0x800 EC_BCCH_FREQ 0x1000 Internal low error code: EC_BCCH_OUTAGE 0x1 EC_NO_BCCH 0x2 EC_FAILED_HOP 0x4 EC_NO_TCH 0x8 EC_NO_SDCCH 0x10 EC_NO_CBCH 0x20 EC_DEGRADED_BARR 0x40 EC_DEGRADED_DIV 0x80 EC_CRIT_THR 0x400 EC_MAJOR_THR 0x200 EC_MINOR_THR 0x100 EC_RESTART_HOP 0x800 EC_BCCH_FREQ 0x1000 BCCH TRX absolute number SCBCH TRX absolute number number of SDCCH channels number of TCH channels IsHopp status value (TRUE/FALSE) AbisHopp value (TRUE/FALSE) High AbisHopp time stamp Low AbisHopp time stamp BTS abis operational state (iope): ENABLED (0x01) DISABLED (0x02) BTS abis availability status (iavlb) DEPENDENCY (0x05) DEGRADED (0x06) NULL (0xFF) Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used

bcch frequency change procedure

bts degraded for bar causes; bts degraded for diversity

bts degraded for bar causes; bts degraded for diversity

A30808-X3247-K240-3-7619

701

Outputs OML:BSC

Base Station Controller

32 = Not used ##fine##

702

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

SYSINFO_ID: 036
SYSTEM INFO REPORT: Originator:

BTSM Failed Alignment Info


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4704 TDHBFDCMC sysinfo description : This notification occurs when the link goes down or a nack message is received during a BTSM alignment procedure. 1 = Incoming event the BTSM DH is handling (dhbfi.h): BMEVT_NONE = 00 BMEVT_TMOUT = 01 BMEVT_SWALGOK = 02 BMEVT_SWALGEND = 03 BMEVT_SWSTRDWLD = 04 BMEVT_SWALGFAIL = 05 BMEVT_SWREFRESH = 06 BMEVT_LINKUP = 07 BMEVT_LINKDOWN = 08 BMEVT_ABISTMT = 09 BMEVT_ABISSENDERR = 0a BMEVT_SYSALGNREQ = 0b BMEVT_AUDITFAIL = 0c BMEVT_MSGDSBL = 0d BMEVT_MSGENBL = 0e BMEVT_STOPEVREP = 0f BMEVT_RSTEVREP = 10 BMEVT_RESETRES = 11 BMEVT_RCVNACK = 12 BMEVT_SMENBL = 13 BMEVT_SMDSBL = 14 BMEVT_SMUNLOCK = 15 BMEVT_DBDHKLV = 16 BMEVT_DBDHERR = 17 BMEVT_DBDHREQ = 18 BMEVT_DBDHRPL = 19 BMEVT_ADMOK = 1a BMEVT_BFSTRTM = 1b BMEVT_ABISDEL = 1c BMEVT_SALESOK, = 1d BMEVT_SALESFAIL = 1e BMEVT_SMLOCK = 1f BMEVT_LOCKOK = 20 2 = Current state of BTSM finite state machine.
A30808-X3247-K240-3-7619 703

Outputs OML:BSC

Base Station Controller

BMFSM_LINK_DOWN = 00 BMFSM_WAIT_STOP_EVT = 01 BMFSM_WAIT_SW_ALIGN = 02 BMFSM_WAIT_DB_ALIGN = 03 BMFSM_WAIT_RESET_RES = 04 BMFSM_WAIT_REST_EVT = 05 BMFSM_WAIT_EVT_REP = 06 BMFSM_MONITOR = 07 BMFSM_WAIT_DBDH = 08 BMFSM_WAIT_RELAX_TIME = 09 BMFSM_WAIT_SALES_EVT = 0a BMFSM_WAIT_LOCK = 0b 3 = NEW state in the BTSM finite state machine. see above. 4 = Not used 5 = Not used 6 = Not used 7 = Not used 8 = Not used 9 = Not used 10 = Not used 11 = Not used 12 = Not used 13 = Not used 14 = Not used 15 = Not used 16 = Not used 17 = Not used 18 = Not used 19 = Not used 20 = Not used 21 = Not used 22 = Not used 23 = Not used 24 = Not used 25 = Not used 26 = Not used 27 = Not used 28 = Not used 29 = Not used 30 = Not used 31 = Not used 32 = Not used ##fine##

704

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

SYSINFO_ID: 037
SYSTEM INFO REPORT: Originator:

BTSM Alignment Required Info


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4704 TDHBFDCMC sysinfo description : This notification occurs when the BTSM DH is required to manage an event not compatible with the current finite state machine, when inconsitencies are detected and when the unlock command is performed by the operator for the BTSM object. 1 = Incoming event the BTSM DH is handling (dhbfi.h): BMEVT_NONE = 00 BMEVT_TMOUT = 01 BMEVT_SWALGOK = 02 BMEVT_SWALGEND = 03 BMEVT_SWSTRDWLD = 04 BMEVT_SWALGFAIL = 05 BMEVT_SWREFRESH = 06 BMEVT_LINKUP = 07 BMEVT_LINKDOWN = 08 BMEVT_ABISTMT = 09 BMEVT_ABISSENDERR = 0a BMEVT_SYSALGNREQ = 0b BMEVT_AUDITFAIL = 0c BMEVT_MSGDSBL = 0d BMEVT_MSGENBL = 0e BMEVT_STOPEVREP = 0f BMEVT_RSTEVREP = 10 BMEVT_RESETRES = 11 BMEVT_RCVNACK = 12 BMEVT_SMENBL = 13 BMEVT_SMDSBL = 14 BMEVT_SMUNLOCK = 15 BMEVT_DBDHKLV = 16 BMEVT_DBDHERR = 17 BMEVT_DBDHREQ = 18 BMEVT_DBDHRPL = 19 BMEVT_ADMOK = 1a BMEVT_BFSTRTM = 1b BMEVT_ABISDEL = 1c BMEVT_SALESOK, = 0x1d BMEVT_SALESFAIL = 0x1e BMEVT_SMLOCK = 0x1f BMEVT_LOCKOK = 0x20
A30808-X3247-K240-3-7619 705

Outputs OML:BSC

Base Station Controller

Current state of BTSM finite state machine. BMFSM_LINK_DOWN = 00 BMFSM_WAIT_STOP_EVT = 01 BMFSM_WAIT_SW_ALIGN = 02 BMFSM_WAIT_DB_ALIGN = 03 BMFSM_WAIT_RESET_RES = 04 BMFSM_WAIT_REST_EVT = 05 BMFSM_WAIT_EVT_REP = 06 BMFSM_MONITOR = 07 BMFSM_WAIT_DBDH = 08 BMFSM_WAIT_RELAX_TIME = 09 BMFSM_WAIT_SALES_EVT = 0x0a BMFSM_WAIT_LOCK = 0x0b 3 = NEW state in the BTSM finite state machine. see above 4 = Not used 5 = Not used 6 = Not used 7 = Not used 8 = Not used 9 = Not used 10 = Not used 11 = Not used 12 = Not used 13 = Not used 14 = Not used 15 = Not used 16 = Not used 17 = Not used 18 = Not used 19 = Not used 20 = Not used 21 = Not used 22 = Not used 23 = Not used 24 = Not used 25 = Not used 26 = Not used 27 = Not used 28 = Not used 29 = Not used 30 = Not used 31 = Not used 32 = Not used ##fine##

2=

706

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

SYSINFO_ID: 038
SYSTEM INFO REPORT: Originator:

BTS No BCCH Available 21 Info


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4700 TDHBFCFMN sysinfo description : This notification occurs when the BTSM DH detects the loss of the BCCH channel with a BTSE in BR21 version. 1 = module line when the Error Collector call is. 2 = BTSM number 3 = BTS relative number 4 = BTSM software release 5 = High BAR condition (DHBFI.H): BAR_NO_BTSM 0x1 btsm disabled or locked BAR_NO_BTS 0x2 bts disabled or locked BAR_NO_TRX 0x4 no one trx enabled-unlocked BAR_NO_BCCH 0x8 no bcch currently available BAR_FAILED_BCCH 0x10 bcch trx locked or disabled dep abis BAR_BCCH_DSBL 0x20 keep barred the cell as long as bcch is not enable BAR_NO_SDCCH 0x40 no sdcch currently available BAR_FAILED_SDCCH 0x80 last sdcch trx locked or disabled dep abis BAR_NO_TCH 0x100 no traffic channel available BAR_TCH_DSBL 0x200 keep barred the cell at least a channel is enabled BAR_FAILED_HOP 0x400 hopping trx locked of disable dep abis BAR_FAILED_CBCH 0x800 cbch trx locked or disabled dep abis BAR_STRTM 0x1000 starting time procedure evolving BAR_ENABLE_HOP 0x2000 restart of hopping procedure BAR_BCCH_FREQ 0x4000 bcch frequency change procedure 6 = Low BAR condition (DHBFI.H): BAR_NO_BTSM 0x1 btsm disabled or locked BAR_NO_BTS 0x2 bts disabled or locked BAR_NO_TRX 0x4 no one trx enabled-unlocked BAR_NO_BCCH 0x8 no bcch currently available BAR_FAILED_BCCH 0x10 bcch trx locked or disabled dep abis BAR_BCCH_DSBL 0x20 keep barred the cell as long as bcch is not enable BAR_NO_SDCCH 0x40 no sdcch currently available BAR_FAILED_SDCCH 0x80 last sdcch trx locked or disabled dep abis BAR_NO_TCH 0x100 no traffic channel available BAR_TCH_DSBL 0x200 keep barred the cell at least a channel is enabled BAR_FAILED_HOP 0x400 hopping trx locked of disable dep abis BAR_FAILED_CBCH 0x800 cbch trx locked or disabled dep abis BAR_STRTM 0x1000 starting time procedure evolving BAR_ENABLE_HOP 0x2000 restart of hopping procedure
A30808-X3247-K240-3-7619 707

Outputs OML:BSC

Base Station Controller

7=

8=

9= 10 = 11 = 12 = 13 = 14 = 15 = 16 = 17 = 18 =

19 = 20 = 21 = 22 = 23 = 24 = 25 = 26 = 27 = 28 = 29 = 30 = 31 =
708

BAR_BCCH_FREQ 0x4000 Internal high error code: EC_BCCH_OUTAGE 0x1 EC_NO_BCCH 0x2 EC_FAILED_HOP 0x4 EC_NO_TCH 0x8 EC_NO_SDCCH 0x10 EC_NO_CBCH 0x20 EC_DEGRADED_BARR 0x40 EC_DEGRADED_DIV 0x80 EC_CRIT_THR 0x400 EC_MAJOR_THR 0x200 EC_MINOR_THR 0x100 EC_RESTART_HOP 0x800 EC_BCCH_FREQ 0x1000 Internal low error code: EC_BCCH_OUTAGE 0x1 EC_NO_BCCH 0x2 EC_FAILED_HOP 0x4 EC_NO_TCH 0x8 EC_NO_SDCCH 0x10 EC_NO_CBCH 0x20 EC_DEGRADED_BARR 0x40 EC_DEGRADED_DIV 0x80 EC_CRIT_THR 0x400 EC_MAJOR_THR 0x200 EC_MINOR_THR 0x100 EC_RESTART_HOP 0x800 EC_BCCH_FREQ 0x1000 BCCH TRX absolute number SCBCH TRX absolute number number of SDCCH channels number of TCH channels IsHopp status value (TRUE/FALSE) AbisHopp value (TRUE/FALSE) High AbisHopp time stamp Low AbisHopp time stamp BTS abis operational state (iope): ENABLED (0x01) DISABLED (0x02) BTS abis availability status (iavlb) DEPENDENCY (0x05) DEGRADED (0x06) NULL (0xFF) Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used

bcch frequency change procedure

bts degraded for bar causes; bts degraded for diversity

bts degraded for bar causes; bts degraded for diversity

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

32 = Not used ##fine##

A30808-X3247-K240-3-7619

709

Outputs OML:BSC

Base Station Controller

SYSINFO_ID: 039
SYSTEM INFO REPORT: Originator:

TRAU SW Alignment Info


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4752 TDHTRDCMC sysinfo description : This notification occurs during the alignmnet procedure when the BSC start the download of a new software on the network element. 1 = Current event that determinated the last alignment TRAU_TMOUT 0x01 timeout occurred TRAU_SMENBL 0x02 status manager ENABLE command TRAU_SMDSBL 0x03 status manager DISABLE command TRAU_SMLOCK 0x04 status manager LOCK command TRAU_SMUNLOCK 0x05 status manager UNLOCK command TRAU_SWALGOK 0x06 successful end of SW alignment TRAU_SWALGFAIL 0x07 failed SW alignment TRAU_SWREFRESH 0x08 refresh from SW alignment process TRAU_SWSTRDWLD 0x09 started download of NE TRAU_SWALGEND 0x0a successful end of download TRAU_SWACTREQ 0x0b software activation request TRAU_LINKUP 0x0c link transition down->up TRAU_LINKDOWN 0x0d link transition up->down TRAU_RCVNACK 0x0e received nack reply during alignment TRAU_MSGDSBL 0x0f notification of TRAU disabled TRAU_MSGENBL 0x10 notification of TRAU enabled TRAU_STOPEVREP 0x11 ack to "Stop sending event report" TRAU_RSTEVREP 0x12 ack to "Restart sending event report" TRAU_RESETRES 0x13 ack to "Reset resource message" TRAU_ASUBTMT 0x14 failed elementary procedure TRAU_ASUBSENDERR 0x15 failed elementary procedure TRAU_AUDITFAIL 0x16 audit of state is not consistent TRAU_ALGNREQ 0x17 alignment request from system TRAU_DBDHKLV 0x18 periodical execution audit from dhdb TRAU_DBDHERR 0x19 failed dbdh procedure TRAU_DBDHREQ 0x1a request queued to dbdh TRAU_DBDHRPL 0x1b reply received from dbdh TRAU_ADMOK 0x1c ackwnoledge of an administrative state procedure TRAU_GIRPL 0x1d consequently a GI SYNCO request the Trau replies. 2 = event that determinated the last alignment in the TRAU main table (the meaning are the same listed above). 3 = current state of main state machine 4 = current state of alignment state machine 5 = TRAU operational state from SM
710 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Note that this field also marks the existence of a certain instance, in case of not equipped instances the value is NO_OPERATIONAL_STATE (0). 6 = TRAU administrative state from SM 7 = TRAU operational state from Abis 8 = TRAU administrative state from Abis 9 = if equal to 0 no shut-down on TRAUm is active otherwise is expiring a timeoutNot used 10 = TRAU availability status from Abis 11 = temporary operational state during TRAU alignment 12 = TRAU usage state (updated by shut-down or get commands only) 13 = identifier for the PCMA alarmNot used 14 = identifier for the PCMA temporary alarm 15 = control alignment of administrative state 16 = control sequence of state audit of Asub (High part) 17 = control sequence of state audit of Asub (Low part) 18 = DBA Server current evolving procedure: object mnemonic involved in the procedure 19 = DBA Server current evolving procedure: first address of the object involved in the procedure 20 = DBA Server current evolving procedure: second address of the object involved in the procedure 21 = DBA Server current evolving procedure: third address of the object involved in the procedure 22 = DBA Server current evolving procedure: fourth address of the object involved in the procedure 23 = DBA Server current evolving procedure: command to be forwarded to DBA Server 24 = counter of the TRAU_FAILEDPROC events for filtering (High part) 25 = counter of the TRAU_FAILEDPROC events for filtering (Low part) 26 = TRUE if failed_align persist. 27 = check if the conf. alarm is already present (High part) 28 = check if the conf. alarm is already present (Low part) 29 = internal error used as return from the function calls (High part) 30 = internal error used as return from the function calls (Low part) 31 = Not used 32 = Not used ##fine##

A30808-X3247-K240-3-7619

711

Outputs OML:BSC

Base Station Controller

SYSINFO_ID: 040
SYSTEM INFO REPORT: Originator:

TRAU Unstable Behavior Info


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4752 TDHTRDCMC sysinfo description : The TRAU DH assert this notification when it detects an abnormal event within a predefined threshold after another abnormal event had been previously detected and triggered an alignmnet procedure. 1 = Current event that determinated the last alignment TRAU_TMOUT 0x01 timeout occurred TRAU_SMENBL 0x02 status manager ENABLE command TRAU_SMDSBL 0x03 status manager DISABLE command TRAU_SMLOCK 0x04 status manager LOCK command TRAU_SMUNLOCK 0x05 status manager UNLOCK command TRAU_SWALGOK 0x06 successful end of SW alignment TRAU_SWALGFAIL 0x07 failed SW alignment TRAU_SWREFRESH 0x08 refresh from SW alignment process TRAU_SWSTRDWLD 0x09 started download of NE TRAU_SWALGEND 0x0a successful end of download TRAU_SWACTREQ 0x0b software activation request TRAU_LINKUP 0x0c link transition down->up TRAU_LINKDOWN 0x0d link transition up->down TRAU_RCVNACK 0x0e received nack reply during alignment TRAU_MSGDSBL 0x0f notification of TRAU disabled TRAU_MSGENBL 0x10 notification of TRAU enabled TRAU_STOPEVREP 0x11 ack to "Stop sending event report" TRAU_RSTEVREP 0x12 ack to "Restart sending event report" TRAU_RESETRES 0x13 ack to "Reset resource message" TRAU_ASUBTMT 0x14 failed elementary procedure TRAU_ASUBSENDERR 0x15 failed elementary procedure TRAU_AUDITFAIL 0x16 audit of state is not consistent TRAU_ALGNREQ 0x17 alignment request from system TRAU_DBDHKLV 0x18 periodical execution audit from dhdb TRAU_DBDHERR 0x19 failed dbdh procedure TRAU_DBDHREQ 0x1a request queued to dbdh TRAU_DBDHRPL 0x1b reply received from dbdh TRAU_ADMOK 0x1c ackwnoledge of an administrative state procedure TRAU_GIRPL 0x1d consequently a GI SYNCO request the Trau replies. 2 = event that determinated the last alignment in the TRAU main table (the meaning are the same listed above). 3 = current state of main state machine 4 = current state of alignment state machine 5 = TRAU operational state from SM
712 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Note that this field also marks the existence of a certain instance, in case of not equipped instances the value is NO_OPERATIONAL_STATE (0). 6 = TRAU administrative state from SM 7 = TRAU operational state from Abis 8 = TRAU administrative state from Abis 9 = if equal to 0 no shut-down on TRAUm is active otherwise is expiring a timeoutNot used 10 = TRAU availability status from Abis 11 = temporary operational state during TRAU alignment 12 = TRAU usage state (updated by shut-down or get commands only) 13 = identifier for the PCMA alarmNot used 14 = identifier for the PCMA temporary alarm 15 = control alignment of administrative state 16 = control sequence of state audit of Asub (High part) 17 = control sequence of state audit of Asub (Low part) 18 = DBA Server current evolving procedure: object mnemonic involved in the procedure 19 = DBA Server current evolving procedure: first address of the object involved in the procedure 20 = DBA Server current evolving procedure: second address of the object involved in the procedure 21 = DBA Server current evolving procedure: third address of the object involved in the procedure 22 = DBA Server current evolving procedure: fourth address of the object involved in the procedure 23 = DBA Server current evolving procedure: command to be forwarded to DBA Server 24 = counter of the TRAU_FAILEDPROC events for filtering (High part) 25 = counter of the TRAU_FAILEDPROC events for filtering (Low part) 26 = TRUE if failed_align persist. 27 = check if the conf. alarm is already present (High part) 28 = check if the conf. alarm is already present (Low part) 29 = internal error used as return from the function calls (High part) 30 = internal error used as return from the function calls (Low part) 31 = Not used 32 = Not used ##fine##

A30808-X3247-K240-3-7619

713

Outputs OML:BSC

Base Station Controller

SYSINFO_ID: 041
SYSTEM INFO REPORT: Originator:

Power Keylock Switch ON


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4606 MDHPRDCSA sysinfo description : The PWRD/EPWR scan recognized that the power off request switch of the affected card, has been pulled up. This transition itself does not affect the power state, it takes effects only if the card is locked. 1 = Line in the code whre the transition has been recognized. 2 = Card status bits returned by the IXLT opposite copy card. 3 = Not used. 4 = Not used. 5 = Not used. 6 = Not used. 7 = Not used. 8 = Not used. 9 = Not used. 10 = Not used. 11 = Not used. 12 = Not used. 13 = Not used. 14 = Not used. 15 = Not used. 16 = Not used. 17 = Not used. 18 = Not used. 19 = Not used. 20 = Not used. 21 = Not used. 22 = Not used. 23 = Not used. 24 = Not used. 25 = Not used. 26 = Not used. 27 = Not used. 28 = Not used. 29 = Not used. 30 = Not used. 31 = Not used. 32 = Not used. ##fine##

714

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

SYSINFO_ID: 042
SYSTEM INFO REPORT: Originator:

Power Keylock Switch OFF


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4606 MDHPRDCSA sysinfo description : The PWRD/EPWR scan recognized that the power off request switch of the affected card, has been pulled down. This transition itself does not affect the power state, it takes effects only if the card is locked, in this case the card will be powered down. 1 = Line in the code where the transition has been recognized. 2 = Card status bits returned by the IXLT opposite copy card 3 = Not used. 4 = Not used. 5 = Not used. 6 = Not used. 7 = Not used. 8 = Not used. 9 = Not used. 10 = Not used. 11 = Not used. 12 = Not used. 13 = Not used. 14 = Not used. 15 = Not used. 16 = Not used. 17 = Not used. 18 = Not used. 19 = Not used. 20 = Not used. 21 = Not used. 22 = Not used. 23 = Not used. 24 = Not used. 25 = Not used. 26 = Not used. 27 = Not used. 28 = Not used. 29 = Not used. 30 = Not used. 31 = Not used. 32 = Not used. ##fine##

A30808-X3247-K240-3-7619

715

Outputs OML:BSC

Base Station Controller

SYSINFO_ID: 043
SYSTEM INFO REPORT: Originator:

DK40 System Info


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4305 MDH40IOSC sysinfo description : System info from DK40 Device Handler, used by the designer to identify the cause of an error from the DK40 subsystem. These System info messages dump several memory locations on MPCC or on the DK40 DUAM. They are output in two cases: 1) error on a single DK40: a system info message of type 0 (see description of word 1) is output, followed by three system info messages (type 1, 2 and 3) dumping the DUAM of the failed DK40 2) mismatch between the two DK40 during a FS operation: a system info message of type 0 is output, followed by six system info messages dumpina the DUAMs of both DK40 cards. 1 = System info type: 0 - DK40 DH Status 1 - DK40 DUAM dump 2 - Message to DK40 3 - Response from DK40 4 - Information from DK40 FW 2 = 0 - Used by the designer to locate the instruction (file id of first calling instruction). 1 - Disk Formatted 2, 3 - Src System + Dst System (DDSS) 3 = 0 - Used by the designer to locate the instruction (line of first calling instruction). 1 - StdbyStatus 2, 3 - Flags + Priority (PPFF) 4 = 0 - Used by the designer to locate the instruction (file id of second calling instruction). 1 - % Disk Free Space 2,3 - Src Mbx 5 = 0 - Used by the designer to locate the instruction (line of second calling instruction). 1 - Diag Resp 2, 3 - Spare 0 6 = 0 - Used by the designer to locate the instruction (file id of third calling instruction). 1 - OpCode 2, 3 - Spare 1 7 = 0 - Used by the designer to locate the instruction (line of third calling instruction). 1 - Fs Busy 2, 3 Dest Mbx 8 = 0 - Used by the designer to locate the instruction (file id of fourth calling instruction). 1 - OpRetCode 2 - Stamp Lo 9 = 0 -Used by the designer to locate the instruction (line of fourth calling instruction). 1 - Fid
716 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

10 =

11 =

12 = 13 =

14 = 15 = 16 = 17 = 18 = 19 = 20 = 21 = 22 = 23 = 24 = 25 = 26 = 27 =

2 - Stamp Hi 0 - Used by the designer to identify the task status 1 - HW Semaphore 0 2 - Signal Type (C9) 3 - Signal Type (CA) 0 - Used by the designer to identify the task status 1 - HW Semaphore 1 2 - Operation Code 3 - Operation Result (0 = OK, 1 = Failed) 0 - Used by the designer to identify the task status 1 - HW Semaphore 2 2, 3 - Datalen 0 - Used by the designer to identify the task status 1 - HW Semaphore 3 2 - Msg Data 3 - Operation Data 0 - Used by the designer to identify the task status 1 - HW Semaphore 4 2, 3 - Msg Data 0 - Used by the designer to identify the task status 1 - HW Semaphore 5 2, 3 - Msg Data 0 - Used by the designer to identify the task status 1 - DUAM Dump 2, 3 - Msg Data 0 - DISK object state 1 - DUAM Dump 2, 3 - Msg Data 0 - DK40 0 object state 1 - DUAM Dump 2, 3 - Msg Data 0 - DK40 1 object state 1 - DUAM Dump 2, 3 - Msg Data 0 - Current object 1 - DUAM Dump 2, 3 - Msg Data 0 - Current event 1 - DUAM Dump 2, 3 - Msg Data 0 - Command sent to DK40 0 1 - DUAM Dump 2, 3 - Msg Data 0 - Command sent to DK40 1 1 - DUAM Dump 2, 3 - Msg Data 0 - Result from DK40 0 1 - DUAM Dump 2, 3 - Msg Data 0 - Result from DK40 1 1 - DUAM Dump 2, 3 - Msg Data 0 - Data from DK40 0 1 - DUAM Dump 2, 3 - Msg Data 0 - Data from DK40 1 1 - DUAM Dump
717

A30808-X3247-K240-3-7619

Outputs OML:BSC

Base Station Controller

2, 3 - Msg Data 0 - Standby status of DK40 0 1 - DUAM Dump 2, 3 - Msg Data 29 = 0 - Standby status of DK40 1 1 - DUAM Dump 2, 3 - Msg Data 30 = 1 - DUAM Dump 2, 3 - Msg Data 31 = 1 - DUAM Dump 2, 3 - Msg Data 32 = 1 - DUAM Dump 2, 3 - Msg Data ##fine## 28 =

718

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

SYSINFO_ID: 045
SYSTEM INFO REPORT: Originator:

BCCH Outage Info


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4700 TDHBFCFMN sysinfo description : This notification occurs when there isnt possibility to recover the BCCH channel. 1 = module line where the Error Collector call is. 2 = BTSM number 3 = BTS relative number 4 = BTSM software release 5 = High BAR condition (DHBFI.H): BAR_NO_BTSM 0x1 btsm disabled or locked BAR_NO_BTS 0x2 bts disabled or locked BAR_NO_TRX 0x4 no one trx enabled-unlocked BAR_NO_BCCH 0x8 no bcch currently available BAR_FAILED_BCCH 0x10 bcch trx locked or disabled dep abis BAR_BCCH_DSBL 0x20 keep barred the cell as long as bcch is not enable BAR_NO_SDCCH 0x40 no sdcch currently available BAR_FAILED_SDCCH 0x80 last sdcch trx locked or disabled dep abis BAR_NO_TCH 0x100 no traffic channel available BAR_TCH_DSBL 0x200 keep barred the cell at least a channel is enabled BAR_FAILED_HOP 0x400 hopping trx locked of disable dep abis BAR_FAILED_CBCH 0x800 cbch trx locked or disabled dep abis BAR_STRTM 0x1000 starting time procedure evolving BAR_ENABLE_HOP 0x2000 restart of hopping procedure BAR_BCCH_FREQ 0x4000 bcch frequency change procedure 6 = Low BAR condition (DHBFI.H): BAR_NO_BTSM 0x1 btsm disabled or locked BAR_NO_BTS 0x2 bts disabled or locked BAR_NO_TRX 0x4 no one trx enabled-unlocked BAR_NO_BCCH 0x8 no bcch currently available BAR_FAILED_BCCH 0x10 bcch trx locked or disabled dep abis BAR_BCCH_DSBL 0x20 keep barred the cell as long as bcch is not enable BAR_NO_SDCCH 0x40 no sdcch currently available BAR_FAILED_SDCCH 0x80 last sdcch trx locked or disabled dep abis BAR_NO_TCH 0x100 no traffic channel available BAR_TCH_DSBL 0x200 keep barred the cell at least a channel is enabled BAR_FAILED_HOP 0x400 hopping trx locked of disable dep abis BAR_FAILED_CBCH 0x800 cbch trx locked or disabled dep abis BAR_STRTM 0x1000 starting time procedure evolving BAR_ENABLE_HOP 0x2000 restart of hopping procedure BAR_BCCH_FREQ 0x4000 bcch frequency change procedure
A30808-X3247-K240-3-7619 719

Outputs OML:BSC

Base Station Controller

7=

8=

9= 10 = 11 = 12 = 13 = 14 = 15 = 16 = 17 = 18 =

19 = 20 = 21 = 22 = 23 = 24 = 25 = 26 = 27 = 28 = 29 = 30 = 31 = 32 =
720

Internal high error code: EC_BCCH_OUTAGE 0x1 EC_NO_BCCH 0x2 EC_FAILED_HOP 0x4 EC_NO_TCH 0x8 EC_NO_SDCCH 0x10 EC_NO_CBCH 0x20 EC_DEGRADED_BARR 0x40 EC_DEGRADED_DIV 0x80 EC_CRIT_THR 0x400 EC_MAJOR_THR 0x200 EC_MINOR_THR 0x100 EC_RESTART_HOP 0x800 EC_BCCH_FREQ 0x1000 Internal low error code: EC_BCCH_OUTAGE 0x1 EC_NO_BCCH 0x2 EC_FAILED_HOP 0x4 EC_NO_TCH 0x8 EC_NO_SDCCH 0x10 EC_NO_CBCH 0x20 EC_DEGRADED_BARR 0x40 EC_DEGRADED_DIV 0x80 EC_CRIT_THR 0x400 EC_MAJOR_THR 0x200 EC_MINOR_THR 0x100 EC_RESTART_HOP 0x800 EC_BCCH_FREQ 0x1000 BCCH TRX absolute number SCBCH TRX absolute number number of SDCCH channels number of TCH channels IsHopp status value (TRUE/FALSE) AbisHopp value (TRUE/FALSE) High AbisHopp time stamp Low AbisHopp time stamp BTS abis operational state (iope): ENABLED (0x01) DISABLED (0x02) BTS abis availability status (iavlb) DEPENDENCY (0x05) DEGRADED (0x06) NULL (0xFF) Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used

bts degraded for bar causes; bts degraded for diversity

bts degraded for bar causes; bts degraded for diversity

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

##fine##

A30808-X3247-K240-3-7619

721

Outputs OML:BSC

Base Station Controller

SYSINFO_ID: 046
SYSTEM INFO REPORT: Originator:

Uncorrect Card Software Status


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4515 DHXXLUSM sysinfo description : This System Info is called when residing SW ( PPXU/PPXL)is in a uncorrect status or not responding to the periodic check 1 = Line 2 = Source line number of specific error detected 3 = Specific error code 4= Item when specific error is detected 5= Error line number of specific error returned to caller 6= Error Item of specific error returned to caller 7 = Byte zero of DUAM's response area 8 = Byte one byte of DUAM's response area 9 = Byte two of DUAM's response area 10 = Byte three of DUAM's response area 11 = Byte four of DUAM's response area 12 = Byte five of DUAM's response area 13 = Byte six of DUAM's response area 14 = Byte seven of DUAM's response area 15 = Ubex Parity Alarm 16 = Card Supervision Alarm 17 = Card Alarm Register 18 = PPXX Configuration Register 19 = SNAP Interface Configuration Register 20 = Byte Twenty in area command (mpcc to ppxx) 21 = Byte Twenty-one in area command (mpcc to ppxx) 22 = Byte Twenty-two in area command (mpcc to ppxx) 23 = Byte Twenty-three in area command (mpcc to ppxx) 24 = Byte Twenty-four in area command (mpcc to ppxx) 25 = Byte Twenty-five in area command (mpcc to ppxx) 26 = Byte Eighty-six in area command (ppxx to mpcc) 27 = Byte Eighty-seven in area command (ppxx to mpcc) 28 = Byte Eighty-eight in area command (ppxx to mpcc) 29 = Byte Eighty-nine in area command (ppxx to mpcc) 30 = Byte Ninety in area command (ppxx to mpcc) 31 = Byte of Status 32 = Byte of Sts Case of XXXX = 4514 DHXXLUSA
722 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

sysinfo description : This System Info is called when periodic check of residing SW (PPXL / PPXU)gives one of the following uncorrect results 1 = Line 2 = Source line number of specific error detected 3 = Specific error code 4 = Item when specific error is detected 5 = Error line number of specific error returned to caller 6 = Error Item of specific error returned to caller 7= Byte zero of DUAM's response area 8= Byte one byte of DUAM's response area 9= Byte two of DUAM's response area 10 = Byte three of DUAM's response area 11 = Byte four of DUAM's response area 12 = Byte five of DUAM's response area 13 = Byte six of DUAM's response area 14 = Byte seven of DUAM's response area 15 = Ubex Parity Alarm 16 = Card Supervision Alarm 17 = Card Alarm Register 18 = PPXX Configuration Register 19 = SNAP Interface Configuration Register 20 = Byte Twenty in area command (mpcc to ppxx) 21 = Byte Eigthy-six in area command (mpcc to ppxx) 22 = Byte Eigthy-seven in area command (mpcc to ppxx) 23 = Byte Eigthy-eigth in area command (mpcc to ppxx) 24 = Byte Eigthty-nine in area command (mpcc to ppxx) 25 = Byte of Status 26 = Byte of Sts 27 = NOT USED 28 = NOT USED 29 = NOT USED 30 = NOT USED 31 = NOT USED 32 = NOT USED

Case of XXXX = 4503 MDHXXDCSA sysinfo description : This System Info is called when periodic check of residing SW gives one of the following uncorrect results: case 1) PPCC and PPLD SW periodic test: a) card is a PPCC and SW state is different from In Service; b) card is a Hot Standby PPLD and SW state is not Start Required (card must be loaded but in FW); c) card is a Providing Service PPLD and SW state is not In Service. case 2) PPCU SW periodic check: a) involved card is Providing Service but its SW state is not Operating b) the card is Cold Standby but its SW state is not Out Of Service Idle 1 = case 1: PPxx operational state (local db) case 2: specific error code (low byte) and source code identifier (high byte) 2 = case 1: PPxx administrative state case 2: source line number of specific error detected 3 = case 1: PPxx stand-by status case 2: error data set at level of routine calling involved driver: error code (low byte) and source code identifier (high byte)
A30808-X3247-K240-3-7619 723

Outputs OML:BSC

Base Station Controller

4= 5= 6= 7= 8= 9= 10 = 11 = 12 = 13 = 14 = 15 = 16 = 17 = 18 = 19 = 20 = 21 = 22 = 23 = 24 = 25 = 26 = 27 = 28 =

case 1: PPxx status (mask of bits) case 2: error data set at level of routine calling involved driver: source line number case 1: logical card (meaningful for PPLD only) case 2: high word of mask of failed PPCU cards case 1: card finite state case 2: low word of mask of failed PPCU cards case 1: error data set at level of routine calling involved driver: error code (low byte) and source code identifier (high byte) case 2: high word of mask of PPCU subjected to periodic check case 1: error data set at level of routine calling involved driver: source line number case 2: low word of mask of PPCU subjected to periodic check case 1: specific error detected: error code (low byte) and source code identifier (high byte) case 2: high word of alarmed PPCU mask case 1: specific error detected: source line number case 2: low word of alarmed PPCU mask case 1: high word of mask of failed PPxx (PPLD 0-14, PPCC 15-16 equivalent to PPCC 0-1) case 2: byte 0 of card answer in Give Status command case 1: low word of mask of failed PPxx case 2: byte 1 of card answer in Give Status command case 1: high word of mask of PPxx subjected to periodic check case 2: byte 2 of card answer in Give Status command case 1: low word of mask of PPxx subjected to periodic check case 2: byte 3 of card answer in Give Status command case 1: high word of alarmed PPxx mask case 2: byte 4 of card answer case 1: low word of alarmed PPxx mask case 2: byte 5 of card answer case 1: alarms not causing interrupts (high byte) and information about parity alarm (if any) (low byte) case 2: byte 6 of card answer case 1: time slots enabled to transmission (high byte) and alarms causing interrupts (low byte) case 2: byte 7 of card answer case 1: second card programming register (high byte) and first card programming register (low byte) case 2: semaphore value on MPCC -> PPCU DUAM interface case 1: SW semaphore value (interface PPLD/PPCC -> DH on MPCC) (high byte) and microprocessor reset register (low byte) case 2: first command byte on MPCC -> PPCU DUAM interface case 1: byte 0 of card answer case 2: second command byte on MPCC -> PPCU DUAM interface case 1: byte 1 of card answer case 2: semaphore value on PPCU -> MPCC DUAM interface case 1: byte 2 of card answer case 2: first answer byte on PPCU -> MPCC DUAM interface case 1: byte 3 of card answer case 2: second answer byte on PPCU -> MPCC DUAM interface case 1: byte 4 of card answer case 2: PPCU operational state (local db) case 1: byte 5 of card answer case 2: PPCU administrative state (local db) case 1: byte 6 of card answer case 2: PPCU standby status (local db) case 1: byte 7 of card answer case 2: PPCU mask of status bits (local db): DEPENDENCY 0x01 FAILED 0x02 INITIALIZING 0x04 IN TEST 0x08
A30808-X3247-K240-3-7619

724

Base Station Controller

Outputs OML:BSC

29 = 30 = 31 = 32 =

NOT INITIALIZED 0x10 OFFLINE 0x20 RESERVED FOR TEST 0x40 NOT INIT ALARMED 0x80 case 1: not used case 2: PCU number (local db) case 1: not used case 2: PPCU finite state (local db) case 1: not used case 2: stored copy of last writing operation on UBEX register (low byte) and bit mask of alarms just read on UBEX register (high byte). case 1: not used case 2: stored value of last detected alarm on PPCU.

Case of XXXX = 4504 MDHXXDCSM sysinfo description : This system info is issued in two cases: a) when check of PPCU residing SW/FW gives an unexpected or uncorrect result during a non-periodic command or state/status change execution b) during a PPLD "switch" (more exactly, when a Providing Service PPLD becomes Disabled or Locked and a Hot Standby card becomes Providing Service), whether a FW problem takes place on one of the involved PPLD cards during status change operations. 1 = case a: current source line case b: PPLD operational state (local database) 2 = case a: source line where problem was detected case b: administrative state (local db) 3 = case a: error code case b: standby status inside local db: HOT STANDBY 1 COLD STANDBY 2 PROVIDING SERVICE 4 4 = case a: source code identifier case b: bit mask of statuses inside local db: DEPENDENCY 0x01 FAILED 0x02 INITIALIZING 0x04 IN TEST 0x08 NOT INITIALIZED 0x10 OFFLINE 0x20 RESERVED FOR TEST 0x40 NOT INIT ALARMED 0x80 5 = case a: source line (point of routine calling failed driver) case b: number of logical PPLD (meaningful for PPLD Device Handler only) 6 = case a: source identifier (routine calling failed driver) case b: finite state inside local db: Idle 0x00 Reset (FW self-test in progress) 0x01 To Be Loaded (awaiting for collecting simultaneous load requests) 0x02 Relax (leaving time to surpass abnormal load situations) 0x03 Waiting For Download (awaiting for load start) 0x04 Load Running (load in progress) 0x05 Load Abort (awaiting for Loading Server answer) 0x06 FW Download Running (FW download in progress via serial port) 0x07 7 = case a: command(s) to PPCU SW/FW (0x1 = START, 0x2 = RUN, 0x3 = START + RUN, 0x4 = START (from FW), 0x5 = START + RUN (from FW), 0x6 = INIT, 0xFF = no state transition) case b: information about routine calling failed driver:
A30808-X3247-K240-3-7619 725

Outputs OML:BSC

Base Station Controller

8= 9= 10 = 11 = 12 = 13 = 14 = 15 = 16 = 17 = 18 = 19 = 20 = 21 =
726

error code (low byte) Unsuccessful Start 0x80 Unsuccessful Forcing To Out Of Service Idle 0x81 Unexpected FW Reply 0x82 Unsuccessful Stop 0x83 Unexpected card SW version 0x85 FW Packet Out Of Sequence 0x86 PPxx_Load_Required 0x88 Nack in Satellited Link Setting 0x89 Timeout (inside MPCC - PPxx commands) 0x8A Unexpected SW state 0x8B Timeout during command from MPCC to PPLD 0x8C Incomplete PID Data 0x8D FW self-test failure 0x90 and source identifier (high byte): DHXXDCCH 1 DHXXDCDE 2 DHXXDCEH 3 DHXXDCSA 4 DHXXDCSM 5 DHXXDCTH 6 DHXXDDDI 7 DHXXDDHD 8 DHXXGSUT 9 DHXXINIT 10 DHXXDGHD 11 DHXXDDPU 12 case a: PPCU SW/FW state at the beginning of routine handling state change and verification case b: line number inside routine calling failed driver case a: SW/FW state at the end of routine case b: error code (low byte) and item identifier (high byte) inside routine failing actions on FW case a: flag (0 = no SW version check; 1 = SW version check inside routine handling SW state change) case b: line number inside routine failing actions on FW case a: byte 0 of card answer in Give Status command case b: alarm cause (low byte) and bit mask of alarms not causing interrupt (high byte) case a: byte 1 of card answer in Give Status command case b: bit mask of alarms causing interrupt (low byte) and mask of enabled time slots (high byte) case a: byte 2 of card answer in Give Status command case b: first card programming register (low byte) and second programming register (high byte) case a: byte 3 of card answer in Give Status command case b: microprocessor reset register (low byte) and SW semaphore in PPxx -> MPCC interface (high byte) case a: semaphore value on MPCC -> PPCU DUAM interface case b: not used case a: first command byte on MPCC -> PPCU DUAM interface case b: not used case a: second command byte on MPCC -> PPCU DUAM interface case b: not used case a: third command byte on MPCC -> PPCU DUAM interface case b: not used case a: semaphore value on PPCU -> MPCC DUAM interface case b: not used case a: first answer byte on PPCU -> MPCC DUAM interface case b: not used case a: second answer byte on PPCU -> MPCC DUAM interface
A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

case b: not used case a: third answer byte on PPCU -> MPCC DUAM interface case b: not used 23 = case a: stored copy of written UBEX register on PPCU-MPCC DUAM (low byte) and alarms read from the same register (high byte) case b: not used 24 = case a: stored last alarms case b: not used 25 = case a: PPCU bit mask of statuses (local db) case b: not used 26 = case a: PPCU finite state (local db) case b: not used 27 = not used 28 = not used 29 = not used 30 = not used 31 = not used 32 = not used ##fine## 22 =

A30808-X3247-K240-3-7619

727

Outputs OML:BSC

Base Station Controller

SYSINFO_ID: 047
SYSTEM INFO REPORT: Originator:

Hardware Problem in Software Check


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 811 TOSICDMCD sysinfo description : There is a NMI TRANSIENT during the check of duam before the access of it. That duam has not the allarm register active. 1 = The number of the DUAM origin of NMI TRANSIENT 2 = TDPC internal register higher part (address 20000028h) before the execution of ppxxAlarm 3 = TDPC internal register lower part (address 20000028h) before the execution of ppxxAlarm 4 = TDPC control point register (address 20000008h) before the execution of ppxxAlarm 5 = TDPC configuration register (address 20000000h) before the execution of ppxxAlarm 6 = TDPC external sense point register (address 20000010h) before the execution of ppxxAlarm 7 = TDPC internal register higher part (address 20000028h) after the execution of ppxxAlarm 8 = TDPC internal register lower part (address 20000028h) after the execution of ppxxAlarm 9 = TDPC control point register (address 20000008h) after the execution of ppxxAlarm 10 = TDPC configuration register (address 20000000h) after the execution of ppxxAlarm 11 = TDPC external sense point register (address 20000010h) after the execution of ppxxAlarm 12 = Not used 13 = Not used 14 = Not used 15 = Not used 16 = Not used 17 = Not used 18 = Not used 19 = Not used 20 = Not used 21 = Not used 22 = Not used 23 = Not used 24 = Not used 25 = Not used 26 = Not used 27 = Not used 28 = Not used 29 = Not used 30 = Not used 31 = Not used 32 = Not used

728

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Case of XXXX = 4514 MDHXXLUSA sysinfo description : This System Info is called in case of HW failure during ppxxBroadCmd 1 = Line 2 = Source line number of specific error detected 3 = Specific error code 4 = Item when specific error is detected 5 = Error line number of specific error returned to caller 6 = Error Item of specific error returned to caller 7 = Byte zero of DUAM's response area 8 = Byte one byte of DUAM's response area 9 = Byte two of DUAM's response area 10 = Byte three of DUAM's response area 11 = Byte four of DUAM's response area 12 = Byte five of DUAM's response area 13 = Byte six of DUAM's response area 14 = Byte seven of DUAM's response area 15 = UBEX Parity Alarm Register 16 = Card Supervision Alarm 17 = Card Alarm Register 18 = PPXX Configuration Register 19 = SNAP Interface Configuration Register 20 = Byte 20 in area command (mpcc to ppxx) 21 = Byte 86 in command area (ppxx to mpcc): operational code 22 = Byte 87 in command area (ppxx to mpcc): command result 23 = Byte 88 in command area (ppxx to mpcc): length of the remaining part of PPXL/PPXU answer 24 = Byte 89 in command area (ppxx to mpcc): event type (1 = fatal Hw error,2 = hw error diagnostic required, 3 = SW error) 25 = Byte of Status 26 = Byte of Sts 27 = NOT USED 28 = NOT USED 29 = NOT USED 30 = NOT USED 31 = NOT USED 32 = NOT USED

Case of XXXX = 4503 MDHXXDCSA sysinfo description : This System Info is generated everywhere a hardware problem is detected during periodic DH -> PPLD/PPCC/PPCU SW interrogation (PPLD/PPCC = case 1; PPCU = case 2) 1 = case 1: PPxx operational state (local db) case 2: specific error code (low byte) and source code identifier (high byte) 2 = case 1: PPxx administrative state case 2: source line number of specific error detected 3 = case 1: PPxx stand-by status case 2: error data set at level of routine calling involved driver: error code (low byte) and source code identifier (high byte) 4 = case 1: PPxx status (mask of bits) case 2: error data set at level of routine calling involved driver: source line number 5 = case 1: logical card (meaningful for PPLD only) case 2: high word of mask of failed PPCU cards 6 = case 1: card finite state
A30808-X3247-K240-3-7619 729

Outputs OML:BSC

Base Station Controller

7= 8= 9= 10 = 11 = 12 = 13 = 14 = 15 = 16 = 17 = 18 = 19 = 20 = 21 = 22 = 23 = 24 = 25 = 26 = 27 = 28 =

29 =
730

case 2: low word of mask of failed PPCU cards case 1: error data set at level of routine calling involved driver: error code (low byte) and source code identifier (high byte) case 2: high word of mask of PPCU subjected to periodic check case 1: error data set at level of routine calling involved driver: source line number case 2: low word of mask of PPCU subjected to periodic check case 1: specific error detected: error code (low byte) and source code identifier (high byte) case 2: high word of alarmed PPCU mask case 1: specific error detected: source line number case 2: low word of alarmed PPCU mask case 1: high word of mask of failed PPxx (PPLD 0-14, PPCC 15-16 equivalent to PPCC 0-1) case 2: byte 0 of card answer in Give Status command case 1: low word of mask of failed PPxx case 2: byte 1 of card answer in Give Status command case 1: high word of mask of PPxx subjected to periodic check case 2: byte 2 of card answer in Give Status command case 1: low word of mask of PPxx subjected to periodic check case 2: byte 3 of card answer in Give Status command case 1: high word of alarmed PPxx mask case 2: byte 4 of card answer case 1: low word of alarmed PPxx mask case 2: byte 5 of card answer case 1: alarms not causing interrupts (high byte) and information about parity alarm (if any) (low byte) case 2: byte 6 of card answer case 1: time slots enabled to transmission (high byte) and alarms causing interrupts (low byte) case 2: byte 7 of card answer case 1: second card programming register (high byte) and first card programming register (low byte) case 2: semaphore value on MPCC -> PPCU DUAM interface case 1: SW semaphore value (interface PPLD/PPCC -> DH on MPCC) (high byte) and microprocessor reset register (low byte) case 2: first command byte on MPCC -> PPCU DUAM interface case 1: byte 0 of card answer case 2: second command byte on MPCC -> PPCU DUAM interface case 1: byte 1 of card answer case 2: semaphore value on PPCU -> MPCC DUAM interface case 1: byte 2 of card answer case 2: first answer byte on PPCU -> MPCC DUAM interface case 1: byte 3 of card answer case 2: second answer byte on PPCU -> MPCC DUAM interface case 1: byte 4 of card answer case 2: PPCU operational state (local db) case 1: byte 5 of card answer case 2: PPCU administrative state (local db) case 1: byte 6 of card answer case 2: PPCU standby status (local db) case 1: byte 7 of card answer case 2: PPCU mask of status bits (local db): DEPENDENCY 0x01 FAILED 0x02 INITIALIZING 0x04 IN TEST 0x08 NOT INITIALIZED 0x10 OFFLINE 0x20 RESERVED FOR TEST 0x40 NOT INIT ALARMED 0x80 case 1: not used
A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

case 2: PCU number (local db) case 1: not used case 2: PPCU finite state (local db) 31 = Not used. 32 = Not used. ##fine## 30 =

A30808-X3247-K240-3-7619

731

Outputs OML:BSC

Base Station Controller

SYSINFO_ID: 048
SYSTEM INFO REPORT: Originator:

Card Software Time Out


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4514 MDHXXLUSA sysinfo description : This System Info is generated when a time-out takes place in PPXL or PPXU or PPCU SW interrogation executed by Device Handler periodic task . 1 = Line 2= Source line number of specific error detected 3 = Specific error code 4 = Item when specific error is detected 5 = Error line number of specific error returned to caller 6 = Error Item of specific error returned to caller 7 = Byte zero of DUAM's response area 8 = Byte one of DUAM's response area 9 = Byte two of DUAM's response area 10 = Byte three of DUAM's response area 11 = Byte four of DUAM's response area 12 = Byte five of DUAM's response area 13 = Byte six of DUAM's response area 14 = Byte seven of DUAM's response area 15 = UBEX Parity Alarm Register 16 = Card Supervision Alarm 17 = Card Alarm Register 18 = PPXX Configuration Register 19 = SNAP Interface Configuration Register 20 = Byte 20 in area command (mpcc to ppxx) 21 = Byte 86 in command area (ppxx to mpcc): operational code 22 = Byte 87 in command area (ppxx to mpcc): command result 23 = Byte 88 in command area (ppxx to mpcc): length of the remaining part of PPXL/PPXU answer 24 = Byte 89 in command area (ppxx to mpcc): event type (1 = fatal Hw error,2 = hw error diagnostic required, 3 = SW error) 25 = Byte of Status 26 = Byte of Sts 27 = NOT USED 28 = NOT USED 29 = NOT USED 30 = NOT USED 31 = NOT USED 32 = NOT USED

732

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Case of XXXX = 4503 MDHXXDCSA sysinfo description : This System Info is generated when a time-out takes place in PPLD or PPCC or PPCU SW interrogation executed by Device Handler periodic task (PPLD/PPCC = case 1; PPCU = case 2). 1 = case 1: PPxx operational state (local db) case 2: specific error code (low byte) and source code identifier (high byte) 2 = case 1: PPxx administrative state case 2: source line number of specific error detected 3 = case 1: PPxx stand-by status case 2: error data set at level of routine calling involved driver: error code (low byte) and source code identifier (high byte) 4 = case 1: PPxx status (mask of bits) case 2: error data set at level of routine calling involved driver: source line number 5 = case 1: logical card (meaningful for PPLD only) case 2: high word of mask of failed PPCU cards 6 = case 1: card finite state case 2: low word of mask of failed PPCU cards 7 = case 1: error data set at level of routine calling involved driver: error code (low byte) and source code identifier (high byte) case 2: high word of mask of PPCU subjected to periodic check 8 = case 1: error data set at level of routine calling involved driver: source line number case 2: low word of mask of PPCU subjected to periodic check 9 = case 1: specific error detected: error code (low byte) and source code identifier (high byte) case 2: high word of alarmed PPCU mask 10 = case 1: specific error detected: source line number case 2: low word of alarmed PPCU mask 11 = case 1: high word of mask of failed PPxx (PPLD 0-14, PPCC 15-16 equivalent to PPCC 0-1) case 2: byte 0 of card answer in Give Status command 12 = case 1: low word of mask of failed PPxx case 2: byte 1 of card answer in Give Status command 13 = case 1: high word of mask of PPxx subjected to periodic check case 2: byte 2 of card answer in Give Status command 14 = case 1: low word of mask of PPxx subjected to periodic check case 2: byte 3 of card answer in Give Status command 15 = case 1: high word of alarmed PPxx mask case 2: byte 4 of card answer 16 = case 1: low word of alarmed PPxx mask case 2: byte 5 of card answer 17 = case 1: alarms not causing interrupts (high byte) and information about parity alarm (if any) (low byte) case 2: byte 6 of card answer 18 = case 1: time slots enabled to transmission (high byte) and alarms causing interrupts (low byte) case 2: byte 7 of card answer 19 = case 1: second card programming register (high byte) and first card programming register (low byte) case 2: semaphore value on MPCC -> PPCU DUAM interface 20 = case 1: SW semaphore value (interface PPLD/PPCC -> DH on MPCC) (high byte) and microprocessor reset register (low byte) case 2: first command byte on MPCC -> PPCU DUAM interface 21 = case 1: byte 0 of card answer case 2: second command byte on MPCC -> PPCU DUAM interface 22 = case 1: byte 1 of card answer case 2: semaphore value on PPCU -> MPCC DUAM interface 23 = case 1: byte 2 of card answer case 2: first answer byte on PPCU -> MPCC DUAM interface 24 = case 1: byte 3 of card answer
A30808-X3247-K240-3-7619 733

Outputs OML:BSC

Base Station Controller

case 2: second answer byte on PPCU -> MPCC DUAM interface case 1: byte 4 of card answer case 2: PPCU operational state (local db) 26 = case 1: byte 5 of card answer case 2: PPCU administrative state (local db) 27 = case 1: byte 6 of card answer case 2: PPCU standby status (local db) 28 = case 1: byte 7 of card answer case 2: PPCU mask of status bits (local db): DEPENDENCY 0x01 FAILED 0x02 INITIALIZING 0x04 IN TEST 0x08 NOT INITIALIZED 0x10 OFFLINE 0x20 RESERVED FOR TEST 0x40 NOT INIT ALARMED 0x80 29 = case 1: not used case 2: PCU number (local db) 30 = case 1: not used case 2: PPCU finite state (local db) 31 = Not used. 32 = Not used. ##fine## 25 =

734

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

SYSINFO_ID: 049
SYSTEM INFO REPORT: Originator:

Full Initialization Requested from TDPC


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4605 MDHPRININ sysinfo description : The MPCC triggered to TDPC card a task initialization, but for some internal problems, the active TDPC answers back to upgrade the initialization level to full. The new initialization starts immediately. 1 = Line in the code where the system info is issued just before the requested full initialization starts. 2 = Not used. 3 = Not used. 4 = Not used. 5 = Not used. 6 = Not used. 7 = Not used. 8 = Not used. 9 = Not used. 10 = Not used. 11 = Not used. 12 = Not used. 13 = Not used. 14 = Not used. 15 = Not used. 16 = Not used. 17 = Not used. 18 = Not used. 19 = Not used. 20 = Not used. 21 = Not used. 22 = Not used. 23 = Not used. 24 = Not used. 25 = Not used. 26 = Not used. 27 = Not used. 28 = Not used. 29 = Not used. 30 = Not used. 31 = Not used. 32 = Not used. Case of XXXX = 4606 MDHPRDCSA
A30808-X3247-K240-3-7619 735

Outputs OML:BSC

Base Station Controller

sysinfo description : The active TDPC card has requested a full initialization to MPCC for some problem on its side during the normal exercise. The initialization will start after 1200 milliseconds. 1 = Line in the code where the system info is issued before the requested full initialization starts. 2 = TDPC internal control bits. 3 = Action that activated the scan handler. 4 = Not used. 5 = Not used. 6 = Not used. 7 = Not used. 8 = Not used. 9 = Not used. 10 = Not used. 11 = Not used. 12 = Not used. 13 = Not used. 14 = Not used. 15 = Not used. 16 = Not used. 17 = Not used. 18 = Not used. 19 = Not used. 20 = Not used. 21 = Not used. 22 = Not used. 23 = Not used. 24 = Not used. 25 = Not used. 26 = Not used. 27 = Not used. 28 = Not used. 29 = Not used. 30 = Not used. 31 = Not used. 32 = Not used. ##fine##

736

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

SYSINFO_ID: 050
SYSTEM INFO REPORT: Originator:

Unexpected Masked NMI


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4600 MDHPRDCDE sysinfo description : The MPCC audit task recognized that NMI are kept masked. The correct situation is restore automatically. 1 = Line in the code where the error has been recognized. 2 = Not used. 3 = Not used. 4 = Not used. 5 = Not used. 6 = Not used. 7 = Not used. 8 = Not used. 9 = Not used. 10 = Not used. 11 = Not used. 12 = Not used. 13 = Not used. 14 = Not used. 15 = Not used. 16 = Not used. 17 = Not used. 18 = Not used. 19 = Not used. 20 = Not used. 21 = Not used. 22 = Not used. 23 = Not used. 24 = Not used. 25 = Not used. 26 = Not used. 27 = Not used. 28 = Not used. 29 = Not used. 30 = Not used. 31 = Not used. 32 = Not used. Case of XXXX = 4900 MDHPRDCSV sysinfo description :
A30808-X3247-K240-3-7619 737

Outputs OML:BSC

Base Station Controller

Every time an audit message is received from MPCC the TDPC audit handler verify also the state of NMI mask, if NMI are found disabled this system info is issued, then the correct state is restored. 1 = Line in the code where the error has been recognized. 2 = Not used. 3 = Not used. 4 = Not used. 5 = Not used. 6 = Not used. 7 = Not used. 8 = Not used. 9 = Not used. 10 = Not used. 11 = Not used. 12 = Not used. 13 = Not used. 14 = Not used. 15 = Not used. 16 = Not used. 17 = Not used. 18 = Not used. 19 = Not used. 20 = Not used. 21 = Not used. 22 = Not used. 23 = Not used. 24 = Not used. 25 = Not used. 26 = Not used. 27 = Not used. 28 = Not used. 29 = Not used. 30 = Not used. 31 = Not used. 32 = Not used. ##fine##

738

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

SYSINFO_ID: 051
SYSTEM INFO REPORT: Originator:

Status Manager data alignment


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 3130 MSMSHPIRM sysinfo description : An internal operation of alignment in Status Managers private data structures has been executed. 1 = Process Source Line 2 = Trans Command Idx / Action 3 = Signal SubType / Target Object Mnemo 4 = Command State / Target Object Unit Address[0] 5 = Object State / Target Object Unit Address[1] 6 = Object Mnemo / Target Object Unit Address[2] 7 = Object Unit Address [0] / Target Object Unit Address[3] 8 = Object Unit Address [1]/ Input Object Menmo 9 = Object Unit Address [2]/ Input Object Unit Address[0] 10 = Object Unit Address [3] / Input Object Unit Address[1] 11 = Not Used / Input Object Unit Address[2] 12 = Not Used / Input Object Unit Address[3] 13 = Not Used / WcScope value 14 = Not Used / TcWildcardScope value 15 = Not Used 16 = Not Used 17 = Not Used 18 = Not Used 19 = Not Used 20 = Not Used 21 = Not Used 22 = Not Used 23 = Not Used 24 = Not Used 25 = Not Used 26 = Not Used 27 = Not Used 28 = Not Used 29 = Not Used 30 = Not Used 31 = Not Used 32 = Not Used Case of XXXX = 3101 MSMSHADSA sysinfo description :
A30808-X3247-K240-3-7619 739

Outputs OML:BSC

Base Station Controller

When an audit action of obj tit cleaned is performed,the six HOLD command enqueued ,if existing,are emitted. 1 = source line 2 = Object Mnemo 3 = Object Unit Address[0] 4 = Object Unit Address[1] 5 = Object Unit Address[2] 6 = Object Unit Address[3] 7 = CurrCh 8 = Object state 9 = ScipTransIdx 10 = TransCmnd 11 = CmdState 12 = Hold Action[0] 13 = Hold Action[1] 14 = Hold Action[2] 15 = Hold Action[3] 16 = Hold Action[4] 17 = Hold Action[5] 18 = Not Used 19 = Not Used 20 = Not Used 21 = Not Used 22 = Not Used 23 = Not Used 24 = Not Used 25 = Not Used 26 = Not Used 27 = Not Used 28 = Not Used 29 = Not Used 30 = Not Used 31 = Not Used 32 = Not Used Case of XXXX = 3132 MSMSHPIHT sysinfo description : Is expired a SuboCnt Timer(internal information). 1 = Source line 2 = Object Mnemo 3 = Object Unit Address[0] 4 = Object Unit Address[1] 5 = Object Unit Address[2] 6 = Object Unit Address[3] 7 = Action 8 = Wildcard Object Mnemo 9 = Wildcard Object Unit Address[0] 10 = Wildcard Object Unit Address[1] 11 = Wildcard Object Unit Address[2] 12 = Wildcard Object Unit Address[3] 13 = WcScope 14 = WcCond 15 = Object state 16 = Object SuboCnt 17 = Subordinate Object Mnemo / Target Action 18 = Subordinate Object Unit Address[0] / Target Object Menmo
740 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

19 = 20 = 21 = 22 = 23 = 24 = 25 = 26 = 27 = 28 = 29 = 30 = 31 = 32 =

Subordinate Object Unit Address[1] / Target Object Unit Address[0] Subordinate Object Unit Address[2] / Target Object Unit Address[1] Subordinate Object Unit Address[3] / Target Object Unit Address[2] Subo Action / Target Object Unit Address[3] Subo State / Not Used Subo Status.avb / Not Used Subo Status.unk / Not Used Subo SuboCnt / Not Used Not Used Not Used Not Used Not Used Not Used Not Used

Case of XXXX = 3140 MSMSHPCCC sysinfo description : When a DH refuses a M.O. Out of Service generated by a LOCK NO FORCE command, Status Manager updates its internal state data base coherently with the previous values (roll back on LOCK command). 1 = Process Source Line 2 = Object Mnemo 3 = Object Unit Address[0] 4 = Object Unit Address[1] 5 = Object Unit Address[2] 6 = Object Unit Address[3] 7 = Not Used 8 = Not Used 9 = Not Used 10 = Not Used 11 = Not Used 12 = Not Used 13 = Not Used 14 = Not Used 15 = Not Used 16 = Not Used 17 = Not Used 18 = Not Used 19 = Not Used 20 = Not Used 21 = Not Used 22 = Not Used 23 = Not Used 24 = Not Used 25 = Not Used 26 = Not Used 27 = Not Used 28 = Not Used 29 = Not Used 30 = Not Used 31 = Not Used 32 = Not Used ##fine##

A30808-X3247-K240-3-7619

741

Outputs OML:BSC

Base Station Controller

SYSINFO_ID: 052
SYSTEM INFO REPORT: Originator:

TRAU Alignment Required Info


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4752 TDHTRDCMC sysinfo description : This notification occurs when a new alignment is required by the sysytem due to an alignment interruped or an unlock TRAU command. 1 = Current event that determinated the last alignment TRAU_TMOUT 0x01 timeout occurred TRAU_SMENBL 0x02 status manager ENABLE command TRAU_SMDSBL 0x03 status manager DISABLE command TRAU_SMLOCK 0x04 status manager LOCK command TRAU_SMUNLOCK 0x05 status manager UNLOCK command TRAU_SWALGOK 0x06 successful end of SW alignment TRAU_SWALGFAIL 0x07 failed SW alignment TRAU_SWREFRESH 0x08 refresh from SW alignment process TRAU_SWSTRDWLD 0x09 started download of NE TRAU_SWALGEND 0x0a successful end of download TRAU_SWACTREQ 0x0b software activation request TRAU_LINKUP 0x0c link transition down->up TRAU_LINKDOWN 0x0d link transition up->down TRAU_RCVNACK 0x0e received nack reply during alignment TRAU_MSGDSBL 0x0f notification of TRAU disabled TRAU_MSGENBL 0x10 notification of TRAU enabled TRAU_STOPEVREP 0x11 ack to "Stop sending event report" TRAU_RSTEVREP 0x12 ack to "Restart sending event report" TRAU_RESETRES 0x13 ack to "Reset resource message" TRAU_ASUBTMT 0x14 failed elementary procedure TRAU_ASUBSENDERR 0x15 failed elementary procedure TRAU_AUDITFAIL 0x16 audit of state is not consistent TRAU_ALGNREQ 0x17 alignment request from system TRAU_DBDHKLV 0x18 periodical execution audit from dhdb TRAU_DBDHERR 0x19 failed dbdh procedure TRAU_DBDHREQ 0x1a request queued to dbdh TRAU_DBDHRPL 0x1b reply received from dbdh TRAU_ADMOK 0x1c ackwnoledge of an administrative state procedure TRAU_GIRPL 0x1d consequently a GI SYNCO request the Trau replies. 2 = event that determinated the last alignment in the TRAU main table (the meaning are the same listed above). 3 = current state of main state machine 4 = current state of alignment state machine 5 = TRAU operational state from SM
742 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Note that this field also marks the existence of a certain instance, in case of not equipped instances the value is NO_OPERATIONAL_STATE (0). 6 = TRAU administrative state from SM 7 = TRAU operational state from Abis 8 = TRAU administrative state from Abis 9 = if equal to 0 no shut-down on TRAUm is active otherwise is expiring a timeoutNot used 10 = TRAU availability status from Abis 11 = temporary operational state during TRAU alignment 12 = TRAU usage state (updated by shut-down or get commands only) 13 = identifier for the PCMA alarmNot used 14 = identifier for the PCMA temporary alarm 15 = control alignment of administrative state 16 = control sequence of state audit of Asub (High part) 17 = control sequence of state audit of Asub (Low part) 18 = DBA Server current evolving procedure: object mnemonic involved in the procedure 19 = DBA Server current evolving procedure: first address of the object involved in the procedure 20 = DBA Server current evolving procedure: second address of the object involved in the procedure 21 = DBA Server current evolving procedure: third address of the object involved in the procedure 22 = DBA Server current evolving procedure: fourth address of the object involved in the procedure 23 = DBA Server current evolving procedure: command to be forwarded to DBA Server 24 = counter of the TRAU_FAILEDPROC events for filtering (High part) 25 = counter of the TRAU_FAILEDPROC events for filtering (Low part)Not used 26 = TRUE if failed_align persist. 27 = check if the conf. alarm is already present (High part) 28 = check if the conf. alarm is already present (Low part) 29 = internal error used as return from the function calls (High part) 30 = internal error used as return from the function calls (Low part) 31 = Not used 32 = Not used ##fine##

A30808-X3247-K240-3-7619

743

Outputs OML:BSC

Base Station Controller

SYSINFO_ID: 053
SYSTEM INFO REPORT: Originator:

Status Manager timer queue refresh


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 3132 MSMSHPIHT sysinfo description : This system info is issued when Status Manager retrieves from internal WAIT queue an object with CurrCh TIT field corrupted. 1 = Mnemonic 2 = Unit_address[0] 3 = Unit_address[1] 4 = Unit_address[2] 5 = Unit_address[3] 6 = CurrCh value contained in TransactionInfoTable structure 7 = State value contained in TransactionInfoTable structure 8 = ScipTransIdx value contained in TransactionInfoTable structure 9 = TransCmnd value contained in TransactionInfoTable structure 10 = Transition Index value contained in structure enqueued in WAIT queue 11 = Time expired value contained in structure enqueued in WAIT queue 12 = Action value contained in structure enqueued in WAIT queue 13 = Retry value contained in structure enqueued in WAIT queue 14 = CmndNbr value contained in structure enqueued in WAIT queue 15 = Mnemonic contained in TransIndexTbl structure 16 = Unit_address[0] contained in TransIndexTbl structure 17 = Unit_address[1] contained in TransIndexTbl structure 18 = Unit_address[2] contained in TransIndexTbl structure 19 = Unit_address[3] contained in TransIndexTbl structure 20 = Action value contained in TransIndexTbl structure 21 = CmndState value contained in TransIndexTbl structure 22 = TcIdx value contained in TransIndexTbl structure 23 = Subtype value contained in TransIndexTbl structure 24 = CmndNbr value contained in TransIndexTbl structure 25 = Not used. 26 = Not used. 27 = Not used. 28 = Not used. 29 = Not used. 30 = Not used. 31 = Not used. 32 = Not used. ##fine##

744

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

SYSINFO_ID: 054
SYSTEM INFO REPORT: Originator:

BTSM Ne Identification Failed Info


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4704 TDHBFDCMC sysinfo description : This notification occurs when the Sales Unique Name set on BTSE side is different from that present in the BSC side. 1 = Internal code of the event. 2 = BTSE sales unique name. 3 = BTSE sales unique name. 4 = BTSE sales unique name. 5 = BTSE sales unique name. 6 = BTSE sales unique name. 7 = BTSE sales unique name. 8 = BTSE sales unique name. 9 = BTSE sales unique name. 10 = BTSE sales unique name. 11 = BTSE sales unique name. 12 = BTSE sales unique name. 13 = Not used. 14 = Not used. 15 = Not used. 16 = Not used. 17 = Not used. 18 = Not used. 19 = Not used. 20 = Not used. 21 = Not used. 22 = Not used. 23 = Not used. 24 = Not used. 25 = Not used. 26 = Not used. 27 = Not used. 28 = Not used. 29 = Not used. 30 = Not used. 31 = Not used. 32 = Not used. ##fine##

A30808-X3247-K240-3-7619

745

Outputs OML:BSC

Base Station Controller

SYSINFO_ID: 055
SYSTEM INFO REPORT: Originator:

TRAU Ne Identification Failed Info


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4752 TDHTRDCMC sysinfo description : This notification occurs when the Sales Unique Name set on TRAUE side is different from that present in the BSC side. 1 = Internal code of the event. 2 = TRAUE sales unique name. 3 = TRAUE sales unique name. 4 = TRAUE sales unique name. 5 = TRAUE sales unique name. 6 = TRAUE sales unique name. 7 = TRAUE sales unique name. 8 = TRAUE sales unique name. 9 = TRAUE sales unique name. 10 = TRAUE sales unique name. 11 = TRAUE sales unique name. 12 = TRAUE sales unique name. 13 = Not used. 14 = Not used. 15 = Not used. 16 = Not used. 17 = Not used. 18 = Not used. 19 = Not used. 20 = Not used. 21 = Not used. 22 = Not used. 23 = Not used. 24 = Not used. 25 = Not used. 26 = Not used. 27 = Not used. 28 = Not used. 29 = Not used. 30 = Not used. 31 = Not used. 32 = Not used. ##fine##

746

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

SYSINFO_ID: 056
SYSTEM INFO REPORT: Originator:

ABIS Channel Mismatch


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 2001 MDBCADHDE sysinfo description : This system info is output when during a Terrestrial Traffic Connection from the ABIS is returned a NACK of the following type : I_CONFLICTING_TIMESLOT_ASSIGNMENT. 1 = network element identifier 2 = message type (in this case the value is always CONN_TERR_TRAFFIC_NACK_MSG) 3 = object class 4 = object instance level 1 5 = object instance level 2 6 = object instance level 3 7 = Nack reason (in this case is always I_CONFLICTING_TIMESLOT_ASSIGNMENT) 8 = port number 9 = timeslot number 10 = subslot number 11 = Not Used 12 = Not Used 13 = Not Used 14 = Not Used 15 = Not Used 16 = Not Used 17 = Not Used 18 = Not Used 19 = Not Used 20 = Not Used 21 = Not Used 22 = Not Used 23 = Not Used 24 = Not Used 25 = Not Used 26 = Not Used 27 = Not Used 28 = Not Used 29 = Not Used 30 = Not Used 31 = Not Used 32 = Not Used ##fine##

A30808-X3247-K240-3-7619

747

Outputs OML:BSC

Base Station Controller

SYSINFO_ID: 057
SYSTEM INFO REPORT: Originator:

X25A Possibly Out of Service


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 3131 MSMSHPICE sysinfo description : This system info is issued when Status Manager receives a LOCK no_force :PCMA that supports an X25A link. 1 = Action 2 = Force /no_force parameter 3 = Mnemonic 4 = Unit address[0] 5 = Unit address[1] 6 = Unit address[2] 7 = Unit address[3] 8 = Not used. 9 = Not used. 10 = Not used. 11 = Not used. 12 = Not used. 13 = Not used. 14 = Not used. 15 = Not used. 16 = Not used. 17 = Not used. 18 = Not used. 19 = Not used. 20 = Not used. 21 = Not used. 22 = Not used. 23 = Not used. 24 = Not used. 25 = Not used. 26 = Not used. 27 = Not used. 28 = Not used. 29 = Not used. 30 = Not used. 31 = Not used. 32 = Not used. ##fine##

748

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

SYSINFO_ID: 058
SYSTEM INFO REPORT: Originator:

Abis Asub Nack


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 2001 MDBCADHDE sysinfo description : This system info is output as Nack response from ABIS or ASUB for all messages different from CONN_TERR_TRAFFIC_NACK_MSG or from Nack different from I_CONFLICTING_TIMESLOT_ASSIGNMENT. 1 = network element identifier 2 = message type 3 = object class 4 = object instance level 1 5 = object instance level 2 6 = object instance level 3 7 = Nack response 8 = Not Used 9 = Not Used 10 = Not Used 11 = Not Used 12 = Not Used 13 = Not Used 14 = Not Used 15 = Not Used 16 = Not Used 17 = Not Used 18 = Not Used 19 = Not Used 20 = Not Used 21 = Not Used 22 = Not Used 23 = Not Used 24 = Not Used 25 = Not Used 26 = Not Used 27 = Not Used 28 = Not Used 29 = Not Used 30 = Not Used 31 = Not Used 32 = Not Used ##fine##

A30808-X3247-K240-3-7619

749

Outputs OML:BSC

Base Station Controller

SYSINFO_ID: 059
SYSTEM INFO REPORT: Originator:

Hot Link Info


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4603 MDHPRDCUT sysinfo description : This system info report is issued when an error has been found upon the Hot Link, either during initialization or starting or diagnostic, for MPCC card. 1 = the line of the source module where the error is issued. 2 = the item where the fault was found. 3 = the line of the item where the fault was found. 4 = the error code of the procedure invoking the system info. 5 = the line of the item where the system info was invoked. 6 = the hot link RX register 0 - link A control. 7 = the hot link RX register 1 - link B control. 8 = the hot link RX register 2 - command. 9 = the hot link RX register 3 - mix HW control. 10 = the hot link RX register 4 - link A RSV counter. 11 = the hot link RX register 5 - link A Bist counter. 12 = the hot link RX register 6 - link B RSV counter. 13 = the hot link RX register 7 - link B Bist counter. 14 = the hot link RX register 8 - link A sense. 15 = the hot link RX register 9 - link B sense. 16 = the hot link RX register 10 - mix HW sense. 17 = the hot link TX register 0 - internal alarm. 18 = the hot link TX register 1 - mask internal alarm. 19 = the hot link TX register 2 - links' alarm / command. 20 = the hot link TX register 3 - links control point. 21 = the hot link TX register 4 - host command / shared ram cfg. 22 = the hot link TX register 5 - FIFO quadword counter. 23 = not used. 24 = not used. 25 = not used. 26 = not used. 27 = not used. 28 = not used. 29 = not used. 30 = not used. 31 = not used. 32 = not used. Case of XXXX = 4900 TDHPRDCSV
750 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

sysinfo description : This system info report is issued when an error has been found upon the Hot Link, either during initialization or starting or diagnostic, for TDPC card. 1 = the line of the source module where the error is issued. 2 = the item where the fault was found. 3 = the line of the item where the fault was found. 4 = the error code of the procedure invoking the system info. 5 = the line of the item where the system info was invoked. 6 = the hot link RX register 0 - link A control. 7 = the hot link RX register 1 - link B control. 8 = the hot link RX register 2 - command. 9 = the hot link RX register 3 - mix HW control. 10 = the hot link RX register 4 - link A RSV counter. 11 = the hot link RX register 5 - link A Bist counter. 12 = the hot link RX register 6 - link B RSV counter. 13 = the hot link RX register 7 - link B Bist counter. 14 = the hot link RX register 8 - link A sense. 15 = the hot link RX register 9 - link B sense. 16 = the hot link RX register 10 - mix HW sense. 17 = the hot link TX register 0 - internal alarm. 18 = the hot link TX register 1 - mask internal alarm. 19 = the hot link TX register 2 - links' alarm / command. 20 = the hot link TX register 3 - links control point. 21 = the hot link TX register 4 - host command / shared ram cfg. 22 = the hot link TX register 5 - FIFO quadword counter. 23 = not used. 24 = not used. 25 = not used. 26 = not used. 27 = not used. 28 = not used. 29 = not used. 30 = not used. 31 = not used. 32 = not used. ##fine##

A30808-X3247-K240-3-7619

751

Outputs OML:BSC

Base Station Controller

SYSINFO_ID: 060
SYSTEM INFO REPORT: Originator:

No Response from Memory Align Server


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4601 MDHPRDCMC sysinfo description : This system info report is issued when the Memory Align Server does not answer to the request of cross copying the standby card, within a predefined time interval, both for MPCC and TDPC. 1 = the line of the source module where the error is issued. 2 = the automa state. 3 = not used. 4 = not used. 5 = not used. 6 = not used. 7 = not used. 8 = not used. 9 = not used. 10 = not used. 11 = not used. 12 = not used. 13 = not used. 14 = not used. 15 = not used. 16 = not used. 17 = not used. 18 = not used. 19 = not used. 20 = not used. 21 = not used. 22 = not used. 23 = not used. 24 = not used. 25 = not used. 26 = not used. 27 = not used. 28 = not used. 29 = not used. 30 = not used. 31 = not used. 32 = not used. ##fine##

752

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

SYSINFO_ID: 061
SYSTEM INFO REPORT: Originator:

Peripheral Software Restarted


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4505 MDHXXDCTH sysinfo description : This System Info is called when the MPCC software gives a start and a stop command, close to each other, to a peripheral processor (PPLD or PPCC) because all the signalling links of this card are failed, so that it is possible that the software on board is stalled. The following conditions are verified when this System Info is called: a) There is at least one signalling link of the card that is failed, but not dependency (in this case it would mean that there are PCM problems) b) There are no signalling links in enabled state on the card c) The pattern going from TRAU/BTS to the PPXX (trapped on the switching matrix) is not idle d) The card is providing service (if PPLD) or unlocked enabled (if PPCC) e) The state of the links, as described in points a), b) and c), is present for the card since long time (at least half hour). 1= 2= 3= 4= 5= 6= 7= 8= 9= 10 = 11 = 12 = 13 = 14 = 15 = 16 = 17 = 18 = 19 = 20 = 21 = 22 = 23 = 24 = 25 = PPxx finite state dump of alarm causes register dump of alarms not causing any interrupt dump of alarms causing interrupts dump of time slots enabled to transmission dump of first programming register dump of second programming register dump of CPU reset register dump of semaphore for PPxx -> DH (on MPCC) interface pattern outgoing from the PPXX on circuit no. 0 pattern outgoing from the PPXX on circuit no. 1 pattern outgoing from the PPXX on circuit no. 2 pattern outgoing from the PPXX on circuit no. 3 pattern outgoing from the PPXX on circuit no. 4 (meaningful only for PPLD) pattern outgoing from the PPXX on circuit no. 5 (meaningful only for PPLD) pattern outgoing from the PPXX on circuit no. 6 (meaningful only for PPLD) pattern outgoing from the PPXX on circuit no. 7 (meaningful only for PPLD) pattern going to the PPXX on circuit no. 0 pattern going to the PPXX on circuit no. 1 pattern going to the PPXX on circuit no. 2 pattern going to the PPXX on circuit no. 3 pattern going to the PPXX on circuit no. 4 pattern going to the PPXX on circuit no. 5 pattern going to the PPXX on circuit no. 6 pattern going to the PPXX on circuit no. 7
753

A30808-X3247-K240-3-7619

Outputs OML:BSC

Base Station Controller

26 = 27 = 28 = 29 = 30 = 31 = 32 =

Not used. Not used. Not used. Not used. Not used. Not used. Not used.

Case of XXXX = 4501 MDHXXDCDE sysinfo description : This system info is issued only for debugging aims, when a complete dump of all time slots on a certain PPCU card is temporarily enabled. 1 = time-slot 0 (low byte) and time-slot 1 (high byte) 2 = time-slot 2 (low byte) and time-slot 3 (high byte) 3 = time-slot 4 (low byte) and time-slot 5 (high byte) 4 = time-slot 6 (low byte) and time-slot 7 (high byte) 5 = time-slot 8 (low byte) and time-slot 9 (high byte) 6 = time-slot 10 (low byte) and time-slot 11 (high byte) 7 = time-slot 12 (low byte) and time-slot 13 (high byte) 8 = time-slot 14 (low byte) and time-slot 15 (high byte) 9 = time-slot 16 (low byte) and time-slot 17 (high byte) 10 = time-slot 18 (low byte0 and time-slot 19 (high byte) 11 = time-slot 20 (low byte) and time-slot 21 (high byte) 12 = time-slot 22 (low byte) and time-slot 23 (high byte) 13 = time-slot 24 (low byte) and time-slot 25 (high byte) 14 = time-slot 26 (low byte) and time-slot 27 (high byte) 15 = time-slot 28 (low byte) and time-slot 29 (high byte) 16 = time-slot 30 (low byte) and time-slot 31 (high byte) 17 = time-slot 32 (low byte) and time-slot 33 (high byte) 18 = time-slot 34 (low byte) and time-slot 35 (high byte) 19 = time-slot 36 (low byte) and time-slot 37 (high byte) 20 = time-slot 38 (low byte) and time-slot 39 (high byte) 21 = time-slot 40 (low byte) and time-slot 41 (high byte) 22 = time-slot 42 (low byte) and time-slot 43 (high byte) 23 = time-slot 44 (low byte) and time-slot 45 (high byte) 24 = time-slot 46 (low byte) and time-slot 47 (high byte) 25 = time-slot 48 (low byte) and time-slot 49 (high byte) 26 = time-slot 50 (low byte) and time-slot 51 (high byte) 27 = time-slot 52 (low byte) and time-slot 53 (high byte) 28 = time-slot 54 (low byte) and time-slot 55 (high byte) 29 = time-slot 56 (low byte) and time-slot 57 (high byte) 30 = time-slot 58 (low byte) and time-slot 59 (high byte) 31 = time-slot 60 (low byte) and time-slot 61 (high byte) 32 = time-slot 62 (low byte) and time-slot 63 (high byte) ##fine##

754

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

SYSINFO_ID: 062
SYSTEM INFO REPORT: Originator:

PLLH restarted
<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4205 MDHNWDCAL sysinfo description : This System Info is called when the PLLH is found in an alarmed state from which it can exit only through a complete restart of the PLLH, including the reset of the local CPU. In particular, one of the following problems may have occurred: a) A CRC protocol error is detected by MPCC in the interface with the local CPU 80186 (the local FW could be stalled in this case) b) The FW has notified to MPCC one of the alarms "PLL unlocked", "VCXO voltage out of range", "DAC or ADC faulted". c) The SN64, SN16 or SNAP detects a timing alarm due to a bad or missing clock from the PLLH d) There are more than one LICD cards that detects at the same time a PCM parity alarm due to a bad signal coming from the SN64, SN16 or SNAP e) There are more than one PPXX cards that detects at the same time a PCM parity alarm due to a bad signal coming from the SN64, SN16 or SNAP All these anomalies can be potentially induced by a bad external synchronization (SYNC or SYNE), and so a last attempt is done, resetting the PLLH, in order to avoid to disable a good PLLH. When this extreme attempt is tried, this system info is issued in order have a trace of this event in the OMC/LMT logfiles. If this PLLH is slave, also the master PLLH is reset. Indeed, for the slave PLLH, the problems could be induced by a bad clock coming from the master PLLH. If the problem occurs again within a certain time (typically half hour), then the PLLH is put definitely disabled. 1 = (Developer oriented): source code line where the system info has been issued 2 = TUNE word of the PLLH before the restart 3 = DAC word of the PLLH before the restart 4 = TUNE word of the other PLLH copy before the restart of this copy. If the other network is disabled, this value can be meaningless. 5 = DAC word of the other PLLH copy before the restart of this copy. If the other network is disabled, this value can be meaningless. 6 = value of the pllh alarm register. The following codes can be logically OR-ed: 0x1 (bit 0): If this bit is set, the PLLH is distributing its own clock signal to the peripheral cards, otherwise it is distributing the clocks of the other PLLH 0x2 (bit 1): the input external synchronism is missing 0x4 (bit 2): the output clock is missing 0x8 (bit 3): the input external source to be measured to is missing 0x10 (bit 4): the PLLH is not synchronized with the other PLLH 0x20 (bit 5): address parity alarm on UBEX bus 0x40 (bit 6): data parity alarm on UBEX bus 0x80 (bit 7): watch dog alarm on the local processor
A30808-X3247-K240-3-7619 755

Outputs OML:BSC

Base Station Controller

Internal FW error code of PLLH: 0x1=>VCXO voltage out of range 0x2=>PLL unlocked 0x3=>Excessive jitter on synchronization source 0x4=>absence of the synchronization source 0x5=>last command from MPCC has not been understood 0x6=>VCXO voltage in the pre-alarm range 0x7=>interruption of the synchronization source 0x8=>eprom checksum failure 0x9=>fault on the DAC or on the ADC 0xA=>fault in the phase comparator 0xD=>CIOA fault (only PLLH V2) 8 = value of the PLLH alarm register of other PLLH 9 = Internal FW error code of other PLLH 10 = State of the PLLH: 0=SLAVE; 1=MASTER 11 = Editions of the 2 PLLH (0=659-7/0035x <x=B,C>, 1=PLLH V1, 2=PLLH V2). In the lower byte, there is the edition of this PLLH, in the higher byte the edition of other copy. 12 = Type of active synchronization source: 44(0x2C): SYNC; 45(0x2D): SYNE; 0xFFFF: PLLH is free running 13 = Instance number of SYNC or SYNE that is active, or 0xFFFF is PLLH is free running 14 = K (where fr. err = K*10(-E)): base of the last frequency error measured for the SYNC or SYNE that is active, or 0xFFFF if PLLH is free running 15 = E (where fr. err = K*10(-E)): exponent of the last frequency error measured for the SYNC or SYNE that is active, or 0xFFFF if PLLH is free running 16 = Frequency in KHz of the SYNC or SYNE that is providing service, or 0xFFFF is PLLH is free running 17 = Phase error measured on the PLLH. The 16th bit is the sign bit; the lowest 15 bits are the absolute value (i.e. without sign) of the phase error. This value is expressed in units of 40 ns. 18 = Phase error (see previous word) measured by the other PLLH. It may be not meaningful if this PLLH is out of service. 19 = Not used. 20 = Not used. 21 = Not used. 22 = Not used. 23 = Not used. 24 = Not used. 25 = Not used. 26 = Not used. 27 = Not used. 28 = Not used. 29 = Not used. 30 = Not used. 31 = Not used. 32 = Not used. ##fine##

7=

756

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

SYSINFO_ID: 063

Ixlt System Info

SYSTEM INFO REPORT: Originator:

<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4455 MDHIXDCUF sysinfo description : This error is issued when the load of the IXLT SW must be aborted. 1= 2= 3= 4= 5= 6= 7= 8= 9= 10 = 11 = 12 = 13 = 14 = 15 = 16 = 17 = 18 = 19 = 20 = 21 = 22 = 23 = 24 = 25 = 26 = 27 = 28 = 29 = 30 = 31 = 32 = the line number in the source module. the bit coded mask indicating which IXLT loading are being aborted. High CallStack Address. Low CallStack Address. High CallStack Address. Low CallStack Address. High CallStack Address. Low CallStack Address. High CallStack Address. Low CallStack Address. High CallStack Address. Low CallStack Address. High CallStack Address. Low CallStack Address. High CallStack Address. Low CallStack Address. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

A30808-X3247-K240-3-7619

757

Outputs OML:BSC

Base Station Controller

Case of XXXX = 4455 MDHIXDCUF sysinfo description : This error is issued when the IXLT must be reset. 1 = the line number in the source module. 2 = High CallStack Address. 3 = Low CallStack Address. 4 = High CallStack Address. 5 = Low CallStack Address. 6 = High CallStack Address. 7 = Low CallStack Address. 8 = High CallStack Address. 9 = Low CallStack Address. 10 = High CallStack Address. 11 = Low CallStack Address. 12 = High CallStack Address. 13 = Low CallStack Address. 14 = High CallStack Address. 15 = Low CallStack Address. 16 = Not used. 17 = Not used. 18 = Not used. 19 = Not used. 20 = Not used. 21 = Not used. 22 = Not used. 23 = Not used. 24 = Not used. 25 = Not used. 26 = Not used. 27 = Not used. 28 = Not used. 29 = Not used. 30 = Not used. 31 = Not used. 32 = Not used. Case of XXXX = 4455 MDHIXDCUF sysinfo description : This error is issued when the IXLT must be reset (it is reported together with the previous one). 1 = ASCII coded value of me_mnemonic of stored IXLT RsuObj. 2 = ASCII coded value of me_address [0] of stored IXLT RsuObj. 3 = ASCII coded value of me_address [1] of stored IXLT RsuObj. 4 = ASCII coded value of me_address [2] of stored IXLT RsuObj. 5 = ASCII coded value of me_address [3] of stored IXLT RsuObj. 6 = ASCII coded value of me_mnemonic of IXLT RsuObj to load. 7 = ASCII coded value of me_address [0] of IXLT RsuObj to load. 8 = ASCII coded value of me_address [1] of IXLT RsuObj to load. 9 = ASCII coded value of me_address [2] of IXLT RsuObj to load. 10 = ASCII coded value of me_address [3] of IXLT RsuObj to load. 11 = Not used. 12 = Not used. 13 = Not used. 14 = Not used. 15 = Not used. 16 = Not used. 17 = Not used.
758 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

18 = 19 = 20 = 21 = 22 = 23 = 24 = 25 = 26 = 27 = 28 = 29 = 30 = 31 = 32 =

Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used. Not used.

Case of XXXX = 4451 MDHIXDCMC sysinfo description : This error is issued when the IXLT card pattern is being corrupted by Device Handler to force recovery action, due to Timeout or Negative Response to periodic polling. 1 = the line number in the source module. 2 = the error event occurred. 3 = Not used. 4 = Not used. 5 = Not used. 6 = Not used. 7 = Not used. 8 = Not used. 9 = Not used. 10 = Not used. 11 = Not used. 12 = Not used. 13 = Not used. 14 = Not used. 15 = Not used. 16 = Not used. 17 = Not used. 18 = Not used. 19 = Not used. 20 = Not used. 21 = Not used. 22 = Not used. 23 = Not used. 24 = Not used. 25 = Not used. 26 = Not used. 27 = Not used. 28 = Not used. 29 = Not used. 30 = Not used. 31 = Not used. 32 = Not used. Case of XXXX = 4451 MDHIXDCMC sysinfo description :
A30808-X3247-K240-3-7619 759

Outputs OML:BSC

Base Station Controller

This error is issued when the IXLT card is not responding - or it is responding with a negative response - to periodic polling, but the IXLT recovery is still not started because other polling will be attempted. 1 = the line number in the source module. 2 = the error event occurred. 3 = Not used. 4 = Not used. 5 = Not used. 6 = Not used. 7 = Not used. 8 = Not used. 9 = Not used. 10 = Not used. 11 = Not used. 12 = Not used. 13 = Not used. 14 = Not used. 15 = Not used. 16 = Not used. 17 = Not used. 18 = Not used. 19 = Not used. 20 = Not used. 21 = Not used. 22 = Not used. 23 = Not used. 24 = Not used. 25 = Not used. 26 = Not used. 27 = Not used. 28 = Not used. 29 = Not used. 30 = Not used. 31 = Not used. 32 = Not used. ##fine##

760

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

SYSINFO_ID: 064
SYSTEM INFO REPORT: Originator:

NSVC UNAVAILABLE INFO


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4953 TDHGPIHGB, 4955 TDHGPIHL3 sysinfo description : It's emitted when the BVC connection has no more serving NSVC available. 1 = line number in source module 2 = BVC operational state: 0 - GP_INS 1 - GP_OOS_M 2 - GP_OOS_F 3 - GP_OOS_P 0xFF - GP_NO_CONFIG 3 = BVC operational state stored in the shared LV3 table vptppkf_tab[ ] (see previous field for values) 4 = BVC protocol state stored in the shared LV3 table vptppkf_tab[ ]: 0 - BVC_ENABLED 1 - BVC_BLOCKED 2 - BVC_DISABLED 5 = Not used 6 = Not used 7 = Not used 8 = Not used 9 = Not used 10 = Not used 11 = Not used 12 = Not used 13 = Not used 14 = Not used 15 = Not used 16 = Not used 17 = Not used 18 = Not used 19 = Not used 20 = Not used 21 = Not used 22 = Not used 23 = Not used 24 = Not used 25 = Not used 26 = Not used 27 = Not used 28 = Not used
A30808-X3247-K240-3-7619 761

Outputs OML:BSC

Base Station Controller

29 = Not used 30 = Not used 31 = Not used 32 = Not used ##fine##

762

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

SYSINFO_ID: 065
SYSTEM INFO REPORT: Originator:

PPCU FIRMWARE TEST FAILED


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4502 MDHXXDCEH sysinfo description : This system info is issued if a PPCU Firmware self-test fails because one of the following circumstances takes place: a) FW auto-diagnostic properly failed (and an error code was returned by this function). b) PPCU driver detected a HW problem during MPCC-PPCU interface. c) No FW answer came after card reset and self-test. 1 = Current source line 2 = Cases a) and c): number of data (in bytes) read by PPCU DH from FW on DUAM case b): - error code (low byte), whose possible values are: 0xe4 = NMI during access to card 0x8f = HW semaphore locked 0xa0 = alarm detection while receiving FW answer - source code where HW problem was detected (high byte): 1 = DHXXDCCH.C 2 = DHXXDCDE 3 = DHXXDCEH 4 = DHXXDCSA 5 = DHXXDCSM 6 = DHXXDCTH 7 = DHXXDDDI 8 = DHXXDDHD 9 = DHXXGSUT 10 = DHXXINIT 11 = DHXXDGHD 12 = DHXXDDPU 3 = cases a) and c): copy of active NTW case b): source line where HW problem was detected 4 = first byte of PCUC FW answer (self-test result is meaningful if value of this byte is 4) 5 = second byte of PCUC FW answer: if value is different from zero, self-test properly failed; this value represents a list of error codes relevant to test failures (data concerning one or more problems are displayed as a bit map): 0x0 = time-out 0x1 = failure inside RAM of PCUC processor 0x2 = failure inside RAM of DSP 0;
A30808-X3247-K240-3-7619 763

Outputs OML:BSC

Base Station Controller

0x4 = failure inside RAM of DSP 1; 0x8 = failure inside RAM of DSP 2; 0x10 = failure inside RAM of DSP 3; 0x20 = failure inside RAM on GbIC processor (Motorola); 0x40= failure inside DUAM (PPCU - TDPC); 0x80 = not used. 6 = third byte of PCUC FW answer 7 = value of SW semafore inside MPCC -> PCUC interface 8 = first byte inside MPCC -> PCUC command area (on DUAM) 9 = second byte inside MPCC -> PCUC command area (on DUAM) 10 = third byte inside MPCC -> PCUC command area (on DUAM) 11 = value of SW semafore inside PCUC -> MPCC interface 12 = first byte inside FW PCUC -> MPCC answer (on DUAM) 13 = second byte inside FW PCUC -> MPCC answer (on DUAM) 14 = third byte inside FW PCUC -> MPCC answer (on DUAM) 15 = copy of last written byte on UBEX register of PPCU (low byte) and alarms mask directly read on it (high byte) 16 = last alarm detected on PPCU card 17 = bit mask of card statuses 18 = counter of retries of reset attempts (and related FW self-tests) 19 = card expiration time (PPCU DH) 20 = not used 21 = not used 22 = not used 23 = not used 24 = not used 25 = not used 26 = not used 27 = not used 28 = not used 29 = not used 30 = not used 31 = not used 32 = not used ##fine##

764

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

SYSINFO_ID: 066
SYSTEM INFO REPORT: Originator:

BVC CONNECTION FAILURE INFO


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4955 TDHGPIHL3 sysinfo description : It's emitted when a protocol error occurs on BVC connection (Gb interface) and a trigger from BSSGP protocol handler (PK) is received by GPRS DH. 1 = line number of source module 2 = Error cause received from LV3: 1 - BVC_RESET_FAILED 2 - BVC_BLOCK_FAILED 3 - BVC_UNBLOCK_FAILED 4 - BVC_FLOWCONTROL_FAILED 3 = Not Used 4 = Not Used 5 = Not Used 6 = Not Used 7 = Not Used 8 = Not Used 9 = Not Used 10 = Not Used 11 = Not Used 12 = Not Used 13 = Not Used 14 = Not Used 15 = Not Used 16 = Not Used 17 = Not Used 18 = Not Used 19 = Not Used 20 = Not Used 21 = Not Used 22 = Not Used 23 = Not Used 24 = Not Used 25 = Not Used 26 = Not Used 27 = Not Used 28 = Not Used 29 = Not Used 30 = Not Used 31 = Not Used
A30808-X3247-K240-3-7619 765

Outputs OML:BSC

Base Station Controller

32 = Not Used ##fine##

766

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

SYSINFO_ID: 067
SYSTEM INFO REPORT: Originator:

PCU ALIGNMENT REQUIRED INFO


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4952 TDHGPDCMC sysinfo description : This notification occurs when a PCU configuration alignment is required. 1 = the line number of the source module 2 = PCU FSM state: 00 - GPFSM_OOS 01 - GPFSM_WAIT_CARD_ON 02 - GPFSM_INITIALIZING 03 - GPFSM_RELAX 04 - GPFSM_MONITOR 3 = Event causing the alignment interruption: 00 - GPEVT_NONE 01 - GPEVT_TMOUT 02 - GPEVT_CARDON 03 - GPEVT_CARDOFF 04 - GPEVT_PCUTMT 05 - GPEVT_PCUSENDERR 06 - GPEVT_PCUALGNREQ 07 - GPEVT_AUDITFAIL 08 - GPEVT_CMDFAIL 09 - GPEVT_CMDRESP 0a - GPEVT_CMDEND 0b - GPEVT_ALGNSTART 0c - GPEVT_SMUNLOCK 0d - GPEVT_SMLOCK 0e - GPEVT_SMDISABLE 0f - GPEVT_SMENABLE 4 = Active Status of first serving PPCU copy (PPCU-0 for PCU-0, PPCU-2 for PCU-1): 0 - Not Active 1 - Active 5 = Active Status of last serving PPCU copy (PPCU-1 for PCU-0, PPCU-3 for PCU-1): 0 - Not Active 1 - Active 6 = Not used 7 = Not used 8 = Not used 9 = Not used 10 = Not used 11 = Not used
A30808-X3247-K240-3-7619 767

Outputs OML:BSC

Base Station Controller

12 = 13 = 14 = 15 = 16 = 17 = 18 = 19 = 20 = 21 = 22 = 23 = 24 = 25 = 26 = 27 = 28 = 29 = 30 = 31 = 32 =

Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used

Case of XXXX = 4951 TDHGPDCDE sysinfo description : This notification occurs when a wrong answear from PCUC is received, a failure occurs while sending a message to PCUC, a timeout expires on an acknowledge from PCUC or GbIC. 1 = the line number of the source module 2 = PCU FSM state: 00 - GPFSM_OOS 01 - GPFSM_WAIT_CARD_ON 02 - GPFSM_INITIALIZING 03 - GPFSM_RELAX 04 - GPFSM_MONITOR 3 = Event causing the alignment interruption: 06 - GPEVT_PCUALGNREQ 4 = Active Status of serving PPCU: 0 - Not Active 1 - Active 5 = Command received (expired) code: 0xff - PC_INVALID_CMD 0x00 - PC_CREATE or GB_CREATE 0x01 - PC_DELETE or GB_DELETE 0x02 - PC_SET or GB_SET 0x03 - PC_GET_INFO or GB_OM_UNBLOCK 0x04 - PC_GET or GB_OM_BLOCK 0x05 - GB_GET 0x06 - GB_GET_COUNTERS 0x07 - GB_GET_STATUS 0x80 - PC_CREATE_ACK or GB_CREATE_ACK 0x81 - PC_DELETE_ACK or GB_DELETE_ACK 0x82 - PC_SET_ACK or GB_SET_ACK 0x83 - PC_GET_INFO_RESPONSE or GB_OM_UNBLOCK_ACK 0x84 - PC_GET_RESPONSE or GB_OM_BLOCK_ACK 0x85 - GB_GET_RESPONSE 0x86 - GB_GET_COUNTERS_RESPONSE 0xC0 - PC_CREATE_NACK or GB_CREATE_NACK
768 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

6=

7= 8= 9= 10 = 11 = 12 = 13 = 14 = 15 = 16 = 17 = 18 = 19 = 20 = 21 = 22 = 23 = 24 = 25 = 26 = 27 = 28 = 29 = 30 = 31 = 32 =

0xC1 - PC_DELETE_NACK or GB_DELETE_NACK 0xC2 - PC_SET_NACK or GB_SET_NACK 0xC3 - PC_GET_RESPONSE_NACK or GB_OM_UNBLOCK_NACK 0xC4 - GB_OM_BLOCK_NACK 0xC5 - GB_GET_NACK 0xC6 - GB_GET_COUNTERS_NACK 0xC7 - GB_GET_STATUS_NACK Command Target Object's class: 0x01 - GbIC_OBJ 0x02 - FRL_OBJ 0x03 - NSVC_OBJ 0x3D - MM_PCU 0x43 - MM_PTPPKF 0x19F - MM_PSCAN Command Target Object's instance Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used

Case of XXXX = 4953 TDHGPIHGB sysinfo description : This error occurs when a wrong answear from GbIC is received. 1 = the line number of the source module 2 = PCU FSM state: 00 - GPFSM_OOS 01 - GPFSM_WAIT_CARD_ON 02 - GPFSM_INITIALIZING 03 - GPFSM_RELAX 04 - GPFSM_MONITOR 3 = Event causing the alignment interruption: 06 - GPEVT_PCUALGNREQ 4 = Active Status of serving PPCU: 0 - Not Active 1 - Active
A30808-X3247-K240-3-7619 769

Outputs OML:BSC

Base Station Controller

5=

6=

7= 8=

9= 10 = 11 = 12 = 13 = 14 = 15 = 16 = 17 = 18 = 19 = 20 = 21 = 22 = 23 = 24 = 25 = 26 = 27 = 28 = 29 = 30 = 31 = 32 =

Command received (expired) code: 0x40 - GB_INVALID_CMD 0xC0 - GB_CREATE_NACK 0xC1 - GB_DELETE_NACK 0xC2 - GB_SET_NACK 0xC3 - GB_OM_UNBLOCK_NACK 0xC4 - GB_OM_BLOCK_NACK 0xC5 - GB_GET_NACK 0xC6 - GB_GET_COUNTERS_NACK 0xC7 - GB_GET_STATUS_NACK Command Target Object's class: 0x01 - GbIC_OBJ 0x02 - FRL_OBJ 0x03 - NSVC_OBJ Command Target Object's instance Nack Cause: 0xFF - OM_ACK_OK 0x00 - OM_ERR_UNKNOWN 0x01 - OM_ERR_GBICU_NOT_CREATED 0x02 - OM_ERR_OBJCLASS 0x03 - OM_ERR_OBJID 0x04 - OM_ERR_CMDTYPE 0x05 - OM_ERR_TIMEOUT 0x06 - OM_ERR_BAD_PARAMETERS 0x07 - OM_ERR_NOT_CREATED 0x08 - OM_ERR_ALREADY_CREATED 0x09 - OM_ERR_ERROR_STATE 0x0A - OM_ERR_NSVC_ATTACHED 0x0B - OM_ERR_NOT_BLOCKED 0x0C - OM_ERR_PH_ERR 0x0D - OM_ERR_FRL_ATTACH Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used

770

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Case of XXXX = 4954 TDHGPIHSM sysinfo description : This notification occurs when a wrong answear from GbIC is received. 1 = the line number of the source module 2 = PCU FSM state: 00 - GPFSM_OOS 01 - GPFSM_WAIT_CARD_ON 02 - GPFSM_INITIALIZING 03 - GPFSM_RELAX 04 - GPFSM_MONITOR 3 = Event causing the alignment interruption: 06 - GPEVT_PCUALGNREQ 4 = Active Status of serving PPCU: 0 - Not Active 1 - Active 5 = Error CODE: 0x10 - GP_ERR_QUEUE_OVERFLOW 0x11 - GP_ERR_PCU_INIT 0x1F - GP_LAST_PCUALIGN_ERR 0x20 - GP_ERR_DATA_INCONSISTENCY 0x21 - GP_ERR_INVALID_RANGE 0x22 - GP_ERR_UNEXPECTED_SIGTYPE 0x23 - GP_ERR_UNEXISTING_INSTANCE 0x24 - GP_ERR_INVALID_MEID 0x25 - GP_ERR_INVALID_SM_ACTION 0x26 - GP_ERR_OBJ_NOT_EQUIPPED 0x27 - GP_ERR_GI_ALREADY_RUN 0x30 - GP_ERR_INVALID_GB_ACTION 6 = Not used 7 = Not used 8 = Not used 9 = Not used 10 = Not used 11 = Not used 12 = Not used 13 = Not used 14 = Not used 15 = Not used 16 = Not used 17 = Not used 18 = Not used 19 = Not used 20 = Not used 21 = Not used 22 = Not used 23 = Not used 24 = Not used 25 = Not used 26 = Not used 27 = Not used 28 = Not used 29 = Not used 30 = Not used 31 = Not used 32 = Not used ##fine##

A30808-X3247-K240-3-7619

771

Outputs OML:BSC

Base Station Controller

SYSINFO_ID: 068
SYSTEM INFO REPORT: Originator:

ABIC FATAL HW PROBLEM


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4503 MDHXXDCSA sysinfo description : This System Info is called when a check on the DSP activity (done on PPCU card during Force In Service command coming from DH on MPCC) returns the following malfunction: loop test on Abis interface of DSP processors failed; more in details, one or more AbIC received some uncorrect PCU Frames from PLD closed in loop mode. 1 = 0x1366 = UDHPDDCMA file identifier 2 = PPCU Agent internal event (0x0007 = End Force In Service) 3 = Abis Loop failure error code (0x0020) 4 = bit mask of PDT channels involved in failure (AbIC-0 -> PDT 0 - 15) 5 = bit mask of PDT channels involved in failure (AbIC-1 -> PDT 16 - 31) 6 = bit mask of PDT channels involved in failure (AbIC-2 -> PDT 32 - 47) 7 = bit mask of PDT channels involved in failure (AbIC-3 -> PDT 48 - 63) 8 = bit mask of failed DSP 9 = not used 10 = not used 11 = not used 12 = not used 13 = not used 14 = not used 15 = not used 16 = not used 17 = not used 18 = not used 19 = not used 20 = not used 21 = not used 22 = not used 23 = not used 24 = not used 25 = not used 26 = not used 27 = not used 28 = not used 29 = not used 30 = not used 31 = not used 32 = not used ##fine##
772 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

SYSINFO_ID: 069
SYSTEM INFO REPORT: Originator:

ABIC HW PROBLEM DIAGNOSTIC REQUIRED


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4503 MDHXXDCSA sysinfo description : This System Info is called when a periodic check on the DSP activity (on PPCU card) returns a malfunction. 1 = 1001 = ABIC KEEP ALIVE ALARM 2 = 136A = PPCU Agent Device Controller Fault Detection Originator) 3 = If "1" DSP interrupt not ok "0" ok 4 = If "1" DSP number 0 not ok, "0" ok 5 = If "1" DSP number 1 not ok, "0" ok 6 = If "1" DSP number 2 not ok, "0" ok 7 = If "1" DSP number 3 not ok, "0" ok 8 = Not Used 9 = Not Used 10 = Not Used 11 = Not Used 12 = Not Used 13 = Not Used 14 = Not Used 15 = Not Used 16 = Not Used 17 = Not Used 18 = Not Used 19 = Not Used 20 = Not Used 21 = Not Used 22 = Not Used 23 = Not Used 24 = Not Used 25 = Not Used 26 = Not Used 27 = Not Used 28 = Not Used 29 = Not Used 30 = Not Used 31 = Not Used 32 = Not Used ##fine##

A30808-X3247-K240-3-7619

773

Outputs OML:BSC

Base Station Controller

SYSINFO_ID: 072
SYSTEM INFO REPORT: Originator:

GBIC HW Problem Diagnostic Required


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4503 MDHXXDCSA sysinfo description : This system info concerns fault detections on GbIC processor, belonging to PPCU card; in fact PPCU Device Handler performs a periodic GbIC check detecting information about faults (if any), written on MPCC-PCUC DUAM by PPCU Agent task. More in details: when a GBIC HW Problem Diagnostic Required occurs, it is followed by other two "GBIC HW Problem Diagnostic Required" SysInfo. For this reason the description of each field shows the meaning of that field in every SysInfo. The first word of the First System Information is the Error Type. . 1 = First SystemInfo, 1040, GBIC KEEP ALIVE PROBLEM 2nd SystemInfo (two words field): performance.data_pool_usage[4].pool_size: number of data buffers, with 256 bytes size, allocated during the initialisation phase; 3rd SystemInfo (two words field) = performance.percent_mem_usage.current_efficiency: averaging calculations made using the history request data to generate the current percentage of memory usage efficiency. 2 = First SysInfo, 136A, PPCU Agent Fault detection Originator 2nd SystemInfo: see previous description; 3rd SystemInfo: see previous description. 3 = First SysInfo = Counter value First Word 2nd SystemInfo (one word field) = performance.data_pool_usage[5].nr_currently_allocated: number of the data buffers, with 512 bytes size, currently allocated; 3rd SystemInfo (two words field) = performance.percent_mem_usage.most_efficient_req: the most efficiency usage of the memory space for a given request so far. 4 = First SysInfo = Counter value Second Word 2nd SystemInfo (one word field) = performance.data_pool_usage[5].most_so_far: highest number of data buffers, with 512 bytes size, currently allocated; 3rd SystemInfo: see previous description. 5 = 1st SystemInfo (two words field) = performance.msg_allocation.nr_currently_allocated: difference between the total number of message reservations and the total number of message releases made at any moment; 2nd SystemInfo (two words field): performance.data_pool_usage[5].pool_size: number of data buffers, with 512 bytes size, allocated during the initialisation phase; 3rd SystemInfo (two words field) = performance.percent_mem_usage.least_efficient_req: the least efficient usage of memory space for a given request so far. 6 = 1st SystemInfo : see previous description; 2nd SystemInfo: see previous description; 3rd SystemInfo: not used. 7 = 1st SystemInfo (two words field) = performance.msg allocation.most so far: peak allocation
774 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

8=

9=

10 = 11 =

12 =

13 =

14 = 15 =

16 =

17 =

occurred until the current moment; 2nd SystemInfo (one word field) = performance.data_pool_usage[6].nr_currently_allocated: number of the data buffers, with 1024 bytes size, currently allocated; 3rd SystemInfo (two words field) = performance.cpu_utilisation.peak_occupancy: CPU utilisation until the current moment. 1st SystemInfo: see previous description; 2nd SystemInfo (one word field) = performance.data_pool_usage[6].most_so_far: highest number of data buffers, with 1024 bytes size, currently allocated; 3rd SystemInfo: see previous description. 1st SystemInfo (two words field) = performance.msg_blk_allocation.nr_currently_allocated: difference between the total number of message block allocations and the total number of message block releases, at any moment; 2nd SystemInfo (two words field) = performance.data_pool_usage[6].pool_size: number of data buffers, with 1024 bytes size, allocated during the initialisation phase; 3rd SystemInfo (two words field) = performance.cpu_utilisation.running_average: averaging calculations made using the rolling history measurement data to generate a fairly accurate running average CPU utilisation over all timing data held in the 'fifo'. 1st SystemInfo: see previous description; 2nd SystemInfo: see previous description; 3rd SystemInfo: see previous description. 1st SystemInfo (two words field) = performance.msg_blk_allocation.nr_currently_free: difference between the size of the free message block pool and the number of the message blocks currently allocated, at any moment; 2nd SystemInfo (one word field) = performance.data_pool_usage[7].nr_currently_allocated: number of the data buffers, with 2048 bytes size, currently allocated; 3rd SystemInfo (two words field) = performance.cpu_utilisation.highest_average: highest average CPU utilisation until the current moment. 1st SystemInfo: see previous description; 2nd SystemInfo (one word field): performance.data_pool_usage[7].most_so_far: highest number of data buffers, with 2048 bytes size, currently allocated; 3rd SystemInfo: see previous description. 1st SystemInfo (two words field) = performance.msg_blk_allocation.most_so_far: peak allocation until the current moment; 2nd SystemInfo (two words field) = performance.data_pool_usage[7].pool_size: number of data buffers, with 2048 bytes size, allocated during the initialisation phase; 3rd SystemInfo (one word field) = health.Fatal_counter: number of the fatal incidents occurred since last initialisation. 1st SystemInfo: see previous description; 2nd SystemInfo: see previous description; 3rd SystemInfo: number of the warnings, occurred since last initialisation. 1st SystemInfo (one word field) = performance.data_pool_usage[0].nr_currently_allocated: number of the data buffers, with 0 byte size, currently allocated; 2nd SystemInfo (one word field) = performance.data_pool_usage[8].nr_currently_allocated: number of the data buffers, with 4096 bytes size, currently allocated; 3rd SystemInfo (two words field) = health.define_as_requirements_arise[]: values of the four elements, belonging to a not used vector. 1st SystemInfo (one word field) = performance.data_pool_usage[0].most_so_far: highest number of data buffers, with 0 bytes size, currently allocated; 2nd SystemInfo (one word field) = performance.data_pool_usage[8].most_so_far: highest number of data buffers, with 4096 bytes size, currently allocated; 3rd SystemInfo: not used. 1st SystemInfo (two words field) = performance.data_pool_usage[0].pool_size: number of data buffers, with 0 byte size, allocated during the initialisation phase; 2nd SystemInfo (two words field) = performance.data_pool_usage[8].pool_size: number of data buffers, with 4096 bytes size, allocated during the initialisation phase; 3rd SystemInfo: not used.
775

A30808-X3247-K240-3-7619

Outputs OML:BSC

Base Station Controller

18 = 19 =

20 =

21 =

22 = 23 =

24 =

25 =

26 = 27 =

28 =

29 =

30 =

1st SystemInfo: see previous description; 2nd SystemInfo: see previous description; 3rd SystemInfo: not used. 1st SystemInfo (one word field) = performance.data_pool_usage[1].nr_currently_allocated: number of the data buffers, with 32 bytes size, currently allocated; 2nd SystemInfo (one word field) = performance.data_pool_usage[9].nr_currently_allocated: not used; 3rd SystemInfo: not used. 1st SystemInfo (one word field) = performance.data_pool_usage[1].most_so_far: highest number of data buffers, with 32 bytes size, currently allocated; 2nd SystemInfo (one word field) = performance.data_pool_usage[9].most_so_far: not used; 3rd SystemInfo: not used. 1st SystemInfo (one word field) = performance.data_pool_usage[1].pool_size: number of data buffers, with 32 bytes size, allocated during the initialisation phase; 2nd SystemInfo (two words field) = performance.data_pool_usage[9].pool_size: not used; 3rd SystemInfo: not used. 1st SystemInfo: see previous description; 2nd SystemInfo: see previous description; 3rd SystemInfo: not used. 1st SystemInfo (one word field) = performance.data_pool_usage[2].nr_currently_allocated: number of data buffers, with 64 bytes size, currently allocated; 2nd SystemInfo (two words field) = performance.mem_size_of_msg_reqs.total_memory_size: every time a message is requested, this counter is incremented by the size of a message requested, giving the total memory size of message request made so far; 3rd SystemInfo: not used. 1st SystemInfo (one word field) = performance.data_pool_usage[2].most_so_far: highest number of data buffers, with 64 byte size, currently allocated; 2nd SystemInfo: see previous description; 3rd SystemInfo: not used. 1st SystemInfo (two words field) = performance.data_pool_usage[2].pool_size: number of data buffers, with 64 bytes size, allocated during the initialisation phase; 2nd SystemInfo (two words field) = performance.mem_size_of_msg_reqs.largest_msg: size of the largest message requested so far; 3rd SystemInfo: not used. 1st SystemInfo: see previous description; 2nd SystemInfo: see previous description; 3rd SystemInfo: not used. 1st SystemInfo (one word field) = performance.data_pool_usage[3].nr_currently_allocated: number of the data buffers, with 128 bytes size, currently allocated; 2nd SystemInfo (two words fields) = performance.mem_size_of_buff_allocs.space_currently_allocated: difference between the total size of the free data buffer pool memory space and the amount of the buffer space currently allocated, at any given moment; 3rd SystemInfo: not used. 1st SystemInfo (one word field) = performance_data_pool_usage[3].most_so_far: highest number of data buffers, with 128 bytes size, currently allocated; 2nd SystemInfo: see previous description; 3rd SystemInfo: not used. 1st SystemInfo (two words field) = performance.data_pool_usage[3].pool_size: number of data buffers, with 128 bytes size, allocated during the initialisation phase; 2nd SystemInfo (two words field) = performance.mem_size_of_buff_allocs.space_currently_free: difference between the total size of the free data buffer pool memory space and the amount of data buffer space currently allocated, at any given moment; 3rd SystemInfo: not used. 1st SystemInfo: see previous description; 2nd SystemInfo: see previous description; 3rd SystemInfo: not used.
A30808-X3247-K240-3-7619

776

Base Station Controller

Outputs OML:BSC

31 =

32 =

1st SystemInfo (one word field) = performance.data_pool_usage[4].nr_currently_allocated: number of the data buffers, with 256 bytes size, currently allocated; 2nd SystemInfo (two words field) = performance.mem_size_of_buff_allocs.most_so_far: peak allocation until the current moment; 3rd SystemInfo: not used. 1st SystemInfo (one word field) = performance.dat_pool_usage[4].most_so_far: highest number of data buffers, with 256 bytes size, currently allocated; 2nd SystemInfo: see previous description; 3rd SystemInfo: not used.

Case of XXXX = 4503 MDHXXDCSA sysinfo description : See also the previous case (this subdivision is done for readibility aims only). The first word of the First System Information is the Error Type. 1= 1st SystemInfo (one word field): 1020, GBIC RESET REQUEST 2nd SystemInfo (two words field) = supplementary_data_info.reg.R4: if an ecception happens (fatal problem), value of the GbIC R4 register; 0, otherwise; 3rd SystemInfo (two words field) = supplementary_data_info.reg.R20: if an ecception happens(fatal error), value of the GbIC R20 register; 0, otherwise; 4th SystemInfo (two words field) = supplementary_data_info.reg.IP: if an ecception happens fatal problem), value of the GbIC IPregister; 0, otherwise. 2= 1st SystemInfo (one word field): 136A, PPCU Agent Fault Detection Originator 2nd SystemInfo (two words field): see previous description; 3rd SystemInfo (two words field): see previous description; 4th SystemInfo (two words field): see previous description. 1st SystemInfo (two words field) = incident.ecception_type: 0, if no ecception happens (when a critical problem happens), otherwise number of ecception (fatal problem); 2nd SystemInfo (two words field) = supplementary_data_info.reg.R5: if an ecception happens (fatal problem), value of the GbIC R5 register; 0, otherwise; 3rd SystemInfo (two words field) = supplementary_data_info.reg.R21: if an ecception happens (fatal problem), value of the GbIC R21 regiter; 0, otherwise; 4th SystemInfo (two words field) = supplementary_data_info.reg.MSR: if an ecception happens (fatal problem), value of the GbIC MSR register; 0, otherwise. see previous description 1st SystemInfo (two words field) = incident.severity: fatal or critical incident severity; 2nd SystemInfo (two words field) = supplementary_data_info.reg.R6: if an ecception happens (fatal problem), value of the GbIC R6 register; 0, otherwise; 3rd SystemInfo (two words field) = supplementary_data_info.reg.R22: if an ecception happens (fatal problem), value of the GbIC R22 register; 0, otherwise; 4th SystemInfo (two words field) = supplementary_data_info.reg.DSISR: if an ecception happens (fatal problem), value of the GbIC DSISR register; 0, otherwise. see previous description 1st SystemInfo (two words field) = incident.location_reference.subsystem: subsystem where the fatal or critical happens; 2nd SystemInfo (two words field) = supplementary_data_info.reg.R7: if an ecception happens (fatal problem), value of the GbIC R7 register; 0, otherwise; 3rd SystemInfo (two words field) = supplementary_data_info.reg.R23: if an ecception happens (fatal problem), value of the GbIC R23 register; 0, otherwise; 4th SystemInfo (two words field) = supplementary_data_info.reg.DAR: if an ecception happens (fatal problem), value of the GbIC DAR register; 0, otherwise. see previous description 1st SystemInfo (two words field) = incident.location_reference.sw_component: sw_component where the fatal or critical happens; 2nd SystemInfo (two words field) = supplementary_data_info.reg.R8: if an ecception happens (fatal problem), value of the GbIC R8 register; 0, otherwise;
777

3=

4= 5=

6= 7=

8= 9=

A30808-X3247-K240-3-7619

Outputs OML:BSC

Base Station Controller

10 = 11 =

12 = 13 =

14 = 15 =

16 = 17 =

18 = 19 =

20 = 21 =

22 = 23 =

3rd SystemInfo (two words field) = supplementary_data_info.reg.R24: if an ecception happens (fatal problem), value of the GbIC R24 register; 0, otherwise; 4th SystemInfo (two words field) = supplementary_data_info.reg.CTR: if an ecception happens (fatal problem), value of the GbIC CTR register; 0, otherwise. see previous description. 1st SystemInfo (two words field) = incident.location_reference.task: task where the fatal or critical problem happens; 2nd SystemInfo (two words field) = supplementary_data_info.reg.R9: if an ecception happens (fatal problem), value of the GbIC R9 register; 0, otherwise; 3rd SystemInfo (two words field) = supplementary_data_info.reg.R25: if an ecception happens (fatal problem), value of the GbIC R25 register; 0, otherwise; 4th SystemInfo (two words field): not used. see previous description. 1st SystemInfo (two words field) = incident.location_reference.module: module where the fatal or critical problem happens; 2nd SystemInfo (two words field) = supplementary_data_info.reg.R10: if an ecception happens (fatal problem), value of the GbIC R10 register; 0, otherwise; 3rd SystemInfo (two words field) = supplementary_data_info.reg.R26: if an ecception happens (fatal problem), value of the GbIC R26 register; 0, otherwise; 4th SystemInfo (two words field): not used. see previous description. 1st SystemInfo (two words field) = incident.location_reference.procedure: procedure where the fatal or critical incident happens; 2nd SystemInfo (two words field) = supplementary_data_info.reg.R11: if an ecception happens (fatal problem), value of the GbIC R11 register; 0, otherwise; 3rd SystemInfo (two words field) = supplementary_data_info.reg.R27: if an ecception happens (fatal problem), value of the GbIC R27 register; 0, otherwise; 4th SystemInfo (two words field): not used. see previous description. 1st SystemInfo (two words field) = incident.location_reference.reporting_point: reporting point where the the fatal or critical incident happens; 2nd SystemInfo (two words field) = supplementary_data_info.reg.R12: if an ecception happens (fatal problem), value of the GbIC R12 register; 0, otherwise; 3rd SystemInfo (two words field) = supplementary_data_info.reg.R28: if an ecception happens (fatal problem), value of the GbIC R28 register; 0, otherwise; 4th SystemInfo (two words field): not used. see previous description. 1st SystemInfo (two words field) = incident.location_reference.PSOS_error_code: value of the global variable, with the last error, occurred during a psos system call; 2nd SystemInfo (two words field) = supplementary_data_info.reg.R13: if an ecception happens (fatal problem), value of the GbIC R13 register; 0, ot herwise; 3rd SystemInfo (two words field) = supplementary_data_info.reg.R29: if an ecception happens (fatal problem), value of the GbIC R29 register; 0, otherwise; 4th SystemInfo (two words field): not used. see previous description. 1st SystemInfo (two words field) = incident.location_reference.MBLK_error_code: value of the global variable, with the last error, occurred during the mblks management; 2nd SystemInfo (two words field) = supplementary_data_info.reg.R14: if an ecception happens (fatal problem), value of the GbIC R14 register; 0, otherwise; 3rd SystemInfo (two words field) = supplementary_data_info.reg.R30: if an ecception happens (fatal problem), value of the GbIC R30 register; 0, otherwise; 4th SystemInfo (two words field): not used. see previous description. 1st SystemInfo (two words field) = incident.location_reference.RTN_error_code: value of the global variable, with the last error occurred in the InterProcessor routines; 2nd SystemInfo (two words field) = supplementary_data_info.reg.R15: if an ecception happens (fatal problem), value of the GbIC R15 register; 0, otherwise;
A30808-X3247-K240-3-7619

778

Base Station Controller

Outputs OML:BSC

24 = 25 =

26 = 27 =

28 = 29 =

30 = 31 =

32 =

3rd SystemInfo (two words field) = supplementary_data_info.reg.R31: if an ecception happens (fatal problem), value of the GbIC R31 register; 0, otherwise; 4th SystemInfo (two words field): not used. see previous description. 1st SystemInfo (two words field) = supplementary_data_info.reg.R0: if an ecception happens (fatal problem), value of the GbIC R0 register; else, if the incident.location_reference.subsystem is the PhysicalBearer (e_phpi), it is a psos error, or an error code defined in the file phpi.h, else 0; 2nd SystemInfo (two words field) = supplementary_data_info.reg.R16: if an ecception happens (fatal problem), value of the GbIC R16 register; 0, otherwise; 3rd SystemInfo (two words field) = supplementary_data_info.reg.CR: if an ecception happens (fatal problem), value of the GbIC CR register; 0, otherwise; 4th SystemInfo (two words field): not used. see previous description. 1st SystemInfo (two words field) = supplementary_data_info.reg.R1: if an ecception happens (fatal problem), value of the GbIC R1 register; 0, otherwise; 2nd SystemInfo (two words field)supplementary_data_info.reg.R17: if an ecception happens (fatal problem), value of the GbIC R17 register; 0, otherwise; 3rd SystemInfo (two words field) = supplementary_data_info.reg.SPR0: if an ecception happens (fatal problem), value of the GbIC SPR0 register; 0, otherwise; 4th SystemInfo (two words field): not used. see previous description. 1st SystemInfo (two words field) = supplementary_data_info.reg.R2: if an ecception happens (fatal problem), value of the GbIC R2 register; 0, otherwise; 2nd SystemInfo (two words field) = supplementary_data_info.reg.R18: if an ecception happens (fatal problem), value of the GbIC R18 register; 0, otherwise; 3rd SystemInfo (two words field) = supplementary_data_info.reg.SPR1: if an ecception happens (fatal problem), value of the GbIC SPR1 register; 0, otherwise; 4th SystemInfo (two words field): not used. see previous description. 1st SystemInfo (two words field) = supplementary_data_info.reg.R3: if an ecception happens (fatal problem), value of the GbIC R3 register; 0, otherwise; 2nd SystemInfo (two words field) = supplementary_data_info.reg.R19: if an ecception happens (fatal problem), value of the GbIC R19 register; 0, otherwise; 3rd SystemInfo (two words field) = supplementary_data_info.reg.LR: if an ecception happens (fatal problem), value of the GbIC LR register; 0, otherwise; 4th SystemInfo (two words field): not used. see previous description.

Case of XXXX = 4503 MDHXXDCSA sysinfo description : See also the previous case (this subdivision is done for readibility aims only). The first word of the First System Information is the Error Type. 1= 1st SystemInfo (one word field): 1080, GBIC INITIALISATION FAILED 2st SystemInfo (two words field): init_diag.point_of_failure.procedure: procedure where the incident occurrs; 3rd SystemInfo (one word field): First Byte = init_diag.supplementary_data[44]: 45-th byte of a not used vector; Second Byte = init_diag.supplementary_data[45]: 46-th byte of a not used vector. 2= 1st SystemInfo (one word field): 1366, PPCU Agent Device Controller Originator 2nd SystemInfo: see previous description; 3rd SystemInfo (one word field): First Byte = init diag.supplementary data[46]: 47-th byte of a not used
A30808-X3247-K240-3-7619 779

Outputs OML:BSC

Base Station Controller

vector; Second Byte = init_diag.supplementary_data[47]: 48-th byte of a not used vector. 3= 1st SystemInfo (one word field): First Byte = init_diag.name[0]: first byte of the string with the name of the function where the incident occurs; Second Byte = init_diag.name[1]: second byte of the string with the name of the function where the incident ocuurs; 2nd SystemInfo (two words field): init_diag.point_of_failure.reporting_point: identificator of the point of the procedure where the incident occurrs; 3rd SystemInfo (one word field): First Byte = init_diag.supplementary_data[48]: 49-th byte of a not used vector; Second Byte = init_diag.supplementary_data[49]: 50-th byte of a not used vector. 1st SystemInfo (one word field): First Byte = init_diag.name[2]: third byte of the string with the name of the function where the incident occurs; Second Byte = init_diag.name[3]: fourth byte of the string with the name of the function where the incident ocuurs; 2nd SystemInfo: see previous description; 3rd SystemInfo (one word field): First Byte = init_diag.supplementary_data[50]: 51-th byte of a not used vector; Second Byte = init_diag.supplementary_data[51]: 52-th byte of a not used vector. 1st SystemInfo (one word field): First Byte = init_diag.name[4]: 6-th byte of the string with the name of the function where the incident occurs; Second Byte = init_dia.name[5]: 7-th byte of the string with the name of the function where the incident ocuurs; 2nd SystemInfo (two words field): init_diag.point_of_failure.PSOS_error_code: value of the global variable with the last error, occurred during a psos call; 3rd SystemInfo (one word field): First Byte = init_diag.supplementary_data[52]: 53-th byte of a not used vector; Second Byte = init_diag.supplementary_data[53]: 54-th byte of a not used vector. 1st SystemInfo (one word field): First Byte = init_diag.name[6]: 7-th byte of the string with the name of the function where the incident occurs; Second Byte = init_diag.name[7]: 8-th byte of the string with the name of the function where the incident ocuurs; 2nd SystemInfo: see previous description; 3rd SystemInfo (one word field): First Byte = init_diag.supplementary_data[54]: 55-th byte of a not used vector; Second Byte = init_diag.supplementary_data[55]: 56-th byte of a not used vector. 1st SystemInfo (one word field): First Byte = init_diag.name[8]: 10-th byte of the string with the name of the function where the incident occurs; Second Byte = init_diag.name[9]: 11-th byte of the string with the name of the function where the incident occurs; 2nd SystemInfo (two words field): init_diag.point_of_failure.MBLK_error_code: value of the global variable with the last error, occurred during the mblks management; 3rd SystemInfo (one word field):
A30808-X3247-K240-3-7619

4=

5=

6=

7=

780

Base Station Controller

Outputs OML:BSC

First Byte = init_diag.supplementary_data[56]: 57-th byte of a not used vector; Second Byte = init_diag.supplementary_data[57]: 58-th byte of a not used vector. 8= 1st SystemInfo (one word field): First Byte = init_diag.na]: 11-th byte of the string with the name of the function where the incident occurs; Second Byte = init_diag.name[11]: 12-th byte of the string with the name of the function where the incident ; 2nd SystemInfo: see previous description; 3rd SystemInfo (one word field): First Byte = init_diag.supplementary_data[58]: 59-th byte of a not used vector; Second Byte = init_diag.supplementary_data[59]: 60-th byte of a not used vector. 1st SystemInfo (one word field): First Byte = init_diag.name[12]: 13-th byte of the string with the name of the function where the incident occurs; Second Byte = init_diag.name[13]: 14-th byte of the string with the name of the function where the incident occurs; 2nd SystemInfo (two words field): init_diag.point_of_failure.RTN_error_code: value of the global variable with the last error, occurred in the InterProcessor procedures; 3rd SystemInfo (one word field): not used. 1st SystemInfo (one word field): First Byte = init_diag.name[14]: 15-th byte of the string with the name of the function where the incident occurs; Second Byte = init_diag.name[15]: 17-th byte of the string with the name of the function where the incident occurs; 2nd SystemInfo: see previous description; 3rd SystemInfo (one word field): not used. 1st SystemInfo (one word field): First Byte = init_diag.name[16]: 17-th byte of the string with the name of the function where the incident occurs; Second Byte = init_diag.name[17]: 18-th byte of the string with the name of the function where the incident occurs; 2nd SystemInfo (one word field): First Byte = init_diag.supplementary_data[0]: fisrt byte of the string with the name of the function where the incident occurs; Second Byte = init_diag.supplementary_data[1]: second byte of the string with the name of the function where the incident occurs; 3rd SystemInfo (one word field): not used. 1st SystemInfo (one word field): First Byte = init_diag.name[18]: 19-th byte of the string with the name of the function where the incident occurs; Second Byte = init_diag.name[19]: 20-th byte of the string with the name of the function where the incident occurs; 2st SystemInfo (one word field): First Byte = init_diag.supplementary_data[2]: third byte of the string with the name of the function where the incident occurs; Second Byte = init_diag.supplementary_data[3]: fourth byte of the string with the name of the function where the incident occurs; 3rd SystemInfo (one word field): not used. 1st SystemInfo (one word field): First Byte = init diag.name[20]: 21-th byte of the string with the name
781

9=

10 =

11 =

12 =

13 =

A30808-X3247-K240-3-7619

Outputs OML:BSC

Base Station Controller

of the function where the incident occurs; Second Byte = init_diag.name[21]: 22-th byte of the string with the name of the function where the incident occurs; 2nd SystemInfo (one word field): First Byte = init_diag.supplementary_data[4]: 5-th byte of a not used vector; Second Byte = init_diag.supplementary_data[5]: 6-th byte of a not used vector; 3rd SystemInfo (one word field): not used. 14 = 1st SystemInfo (one word field): First Byte = init_diag.name[22]: 23-th byte of the string with the name of the function where the incident occurs; Second Byte = init_diag.name[23]: 24-th byte of the string with the name of the function where the incident occurs; 2nd SystemInfo (one word field): First Byte = init_diag.supplementary_data[6]: 7-th byte of a not used vector; Second Byte = init_diag.supplementary_data[7]: 8-th byte of a not used vector; 3rd SystemInfo (one word field): not used. 1st SystemInfo (one word field): First Byte = init_diag.reason_for_failure[0]: first byte of the string with the incident reason; Second Byte = init_diag.reason_for_failure[1]: second byte of the string with the incident reason; 2nd SystemInfo (one word field): First Byte = init_diag.supplementary_data[8]: 9-th byte of a not used vector; Second Byte = init_diag.supplementary_data[9]: 10-th byte of a not used vector; 3rd SystemInfo (one word field): not used. 1st SystemInfo (one word field): First Byte = init_diag.reason_for_failure[2]: third byte of the string with the incident reason; Second Byte = init_diag.reason_for_failure[3]: fouth byte of the string with the incident reason; 2nd SystemInfo (one word field): First Byte = init_diag.supplementary_data[10]: 11-th byte of a not used vector; Second Byte = init_diag.supplementary_data[11]: 12-th byte of a not used vector; 3rd SystemInfo (one word field): not used. 1st SystemInfo (one word field): First Byte = init_diag.reason_for_failure[4]: 5-th byte of the string with the incident reason; Second Byte = init_diag.reason_for_failure[5]: 6-th byte of the string with the incident reason; 2nd SystemInfo (one word field): First Byte = init_diag.supplementary_data[12]: 13-th byte of a not used vector; Second Byte = init_diag.supplementary_data[13]: 14-th byte of a not used vector; 3rd SystemInfo (one word field): not used.
A30808-X3247-K240-3-7619

15 =

16 =

17 =

782

Base Station Controller

Outputs OML:BSC

18 =

1st SystemInfo (one word field): First Byte = init_diag.reason_for_failure[6]: 8-th byte of the string with the incident reason; Second Byte = init_diag.reason_for_failure[7]: 9-th byte of the string with the incident reason; 2nd SystemInfo (one word field): First Byte = init_diag.supplementary_data[14]: 15-th byte of a not used vector; Second Byte = init_diag.supplementary_data[15]: 16-th byte of a not used vector; 3rd SystemInfo (one word field): not used. 1st SystemInfo (one word field): First Byte = init_diag.reason_for_failure[8]: 9-th byte of the string with the name of the function where the incident occurs; Second Byte = init_diag.reason_for_failure[9]: 11-th byte of the string with the name of the function where the incident occurs; 2nd SystemInfo (one word field): First Byte = init_diag.supplementary_data[16]: 17-th byte of a not used vector; Second Byte = init_diag.supplementary_data[17]: 18-th byte of a not used vector; 3rd SystemInfo (one word field): not used. 1st SystemInfo (one word field): First Byte = init_diag.reason_for_failure[10]: 11-th byte of the string with the name of the function where the incident occurs; Second Byte = init_diag.reason_for_failure[11]: 12-th byte of the string with the name of the function where the incident occurs; 2nd SystemInfo (one word field): First Byte = init_diag.supplementary_data[18]: 19-th byte of a not used vector; Second Byte = init_diag.supplementary_data[19]: 20-th byte of a not used vector; 3rd SystemInfo (one word field): not used. 1st SystemInfo (one word field): First Byte = init_diag.reason_for_failure[12]: 13-th byte of the string with the name of the function where the incident occurs; Second Byte = init_diag.reason_for_failure[13]: 14-th byte of the string with the name of the function where the incident occurs; 2nd SystemInfo (one word field): First Byte = init_diag.supplementary_data[20]: 21-th byte of a not used vector; Second Byte = init_diag.supplementary_data[21]: 22-th byte of a not used vector; 3rd SystemInfo (one word field): not used. 1st SystemInfo (one word field): First Byte = init_diag.reason_for_failure[14]: 15-th byte of the string with the name of the function where the incident occurs; Second Byte = init_diag.reason_for_failure[15]: 16-th byte of the string with the name of the function where the incident occurs; 2nd SystemInfo (one word field): First Byte = init_diag.supplementary_data[22]: 23-th byte of a not used vector;
783

19 =

20 =

21 =

22 =

A30808-X3247-K240-3-7619

Outputs OML:BSC

Base Station Controller

Second Byte = init_diag.supplementary_data[23]: 24-th byte of a not used vector; 3rd SystemInfo (one word field): not used. 23 = 1st SystemInfo (one word field): First Byte = init_diag.reason_for_failure[16]: 17-th byte of the string with the name of the function where the incident occurs; Second Byte = init_diag.reason_for_failure[17]: 18-th byte of the string with the name of the function where the incident occurs; 2nd SystemInfo (one word field): First Byte = init_diag.supplementary_data[24]: 24-th byte of a not used vector; Second Byte = init_diag.supplementary_data[25]: 25-th byte of a not used vector; 3rd SystemInfo (one word field): not used. 1st SystemInfo (one word field): First Byte = init_diag.reason_for_failure[18]: 19-th byte of the string with the name of the function where the incident occurs; Second Byte = init_diag.reason_for_failure[19]: 20-th byte of the string with the name of the function where the incident occurs; 2nd SystemInfo (one word field): First Byte = init_diag.supplementary_data[26]: 27-th byte of a not used vector; Second Byte = init_diag.supplementary_data[27]: 28-th byte of a not used vector; 3rd SystemInfo (one word field): not used. 1st SystemInfo (two words field): init_diag.point_of_failure.subsytem: system where the incident occurs; 2nd SystemInfo (one word field): First Byte = init_diag.supplementary_data[28]: 29-th byte of a not used vector; Second Byte = init_diag.supplementary_data[29]: 30-th byte of a not used vector; 3rd SystemInfo (one word field): not used. 1st SystemInfo: see previous description; 2nd SystemInfo (one word field): First Byte = init_diag.supplementary_data[30]: 31-th byte of a not used vector; Second Byte = init_diag.supplementary_data[31]: 32-th byte of a not used vector. 3rd SystemInfo (one word field): not used. 27 = 1st SystemInfo (two words field): init_diag.point_of_failure.sw_component: component where the incident occurs; 2nd SystemInfo (one word field): First Byte = init_diag.supplementary_data[32]: 33-th byte of a not used vector; Second Byte = init_diag.supplementary_data[33]: 34-th byte of a not used vector; 3rd SystemInfo (one word field): not used. 1st SystemInfo: see previous description; 2nd SystemInfo (one word field): First Byte = init diag.supplementary data[34]: 35-th byte of a not used
A30808-X3247-K240-3-7619

24 =

25 =

26 =

28 =

784

Base Station Controller

Outputs OML:BSC

vector; Second Byte = init_diag.supplementary_data[35]: 36-th byte of a not used vector; 3rd SystemInfo (one word field): not used. 29 = 1st SystemInfo (two words field): init_diag.point_of_failure.task: task where the incident occurs; 2nd SystemInfo (one word field): First Byte = init_diag.supplementary_data[36]: 36-th byte of a not used vector; Second Byte = init_diag.supplementary_data[37]: 37-th byte of a not used vector; 3rd SystemInfo (one word field): not used. 1st SystemInfo: see previous description; 2nd SystemInfo (one word field): First Byte = init_diag.supplementary_data[38]: 39-th byte of a not used vector; Second Byte = init_diag.supplementary_data[39]: 40-th byte of a not used vector; 3rd SystemInfo (one word field): not used. 31 = 1st SystemInfo (two words field): init_diag.point_of_failure.module: module where the incident occurs; 2nd SystemInfo (one word field): First Byte = init_diag.supplementary_data[40]: 41-th byte of a not used vector; Second Byte = init_diag.supplementary_data[41]: 42-th byte of a not used vector; 3rd SystemInfo (one word field): not used. 1st SystemInfo: see previous description; 2nd SystemInfo (one word field): First Byte = init_diag.supplementary_data[42]: 43-th byte of a not used vector; Second Byte = init_diag.supplementary_data[43]: 44-th byte of a not used vector; 3rd SystemInfo (one word field): not used. ##fine##

30 =

32 =

A30808-X3247-K240-3-7619

785

Outputs OML:BSC

Base Station Controller

SYSINFO_ID: 073
SYSTEM INFO REPORT: Originator:

GBIC SW Problem
<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4503 MDHXXDCSA sysinfo description : This system info is issued when a periodic check performed by PPCU Device Handler detects on PCUCMPCC DUAM some information written by PPCU Agent and concerning SW problems on GbIC processor (belonging to PPCU card). More in details: when a "GBIC SW Problem" occurs, it is always followed by other three "GBIC SW Problem" SystemInfo. For this reason the description of each field shows the meaning of the field in every SystemInfo. The first word of the First System Information is the Error Type. 1= 1st SystemInfo (one word field): 1020, GBIC RESET REQUEST 2nd SystemInfo (two words field) = supplementary_data_info.reg.R4: if an ecception happens (fatal problem), value of the GbIC R4 register; 0, otherwise; 3rd SystemInfo (two words field) = supplementary_data_info.reg.R20: if an ecception happens(fatal error), value of the GbIC R20 register; 0, otherwise; 4th SystemInfo (two words field) = supplementary_data_info.reg.IP: if an ecception happens fatal problem), value of the GbIC IPregister; 0, otherwise. 1st SystemInfo (one word field): 136A, PPCU Agent Fault Detection Originator 2nd SystemInfo (two words field): see previous description; 3rd SystemInfo (two words field): see previous description; 4th SystemInfo (two words field): see previous description. 1st SystemInfo (two words field) = incident.ecception_type: 0, if no ecception happens (when a critical problem happens), otherwise number of ecception (fatal problem); 2nd SystemInfo (two words field) = supplementary_data_info.reg.R5: if an ecception happens (fatal problem), value of the GbIC R5 register; 0, otherwise; 3rd SystemInfo (two words field) = supplementary_data_info.reg.R21: if an ecception happens (fatal problem), value of the GbIC R21 regiter; 0, otherwise; 4th SystemInfo (two words field) = supplementary_data_info.reg.MSR: if an ecception happens (fatal problem), value of the GbIC MSR register; 0, otherwise. see previous description 1st SystemInfo (two words field) = incident.severity: fatal or critical incident severity; 2nd SystemInfo (two words field) = supplementary_data_info.reg.R6: if an ecception happens (fatal problem), value of the GbIC R6 register; 0, otherwise; 3rd SystemInfo (two words field) = supplementary_data_info.reg.R22: if an ecception happens (fatal problem), value of the GbIC R22 register; 0, otherwise; 4th SystemInfo (two words field) = supplementary_data_info.reg.DSISR: if an ecception happens (fatal problem), value of the GbIC DSISR register; 0, otherwise. see previous description
A30808-X3247-K240-3-7619

2=

3=

4= 5=

6=
786

Base Station Controller

Outputs OML:BSC

7=

8= 9=

10 = 11 =

12 = 13 =

14 = 15 =

16 = 17 =

18 = 19 =

1st SystemInfo (two words field) = incident.location_reference.subsystem: subsystem where the fatal or critical happens; 2nd SystemInfo (two words field) = supplementary_data_info.reg.R7: if an ecception happens (fatal problem), value of the GbIC R7 register; 0, otherwise; 3rd SystemInfo (two words field) = supplementary_data_info.reg.R23: if an ecception happens (fatal problem), value of the GbIC R23 register; 0, otherwise; 4th SystemInfo (two words field) = supplementary_data_info.reg.DAR: if an ecception happens (fatal problem), value of the GbIC DAR register; 0, otherwise. see previous description 1st SystemInfo (two words field) = incident.location_reference.sw_component: sw_component where the fatal or critical happens; 2nd SystemInfo (two words field) = supplementary_data_info.reg.R8: if an ecception happens (fatal problem), value of the GbIC R8 register; 0, otherwise; 3rd SystemInfo (two words field) = supplementary_data_info.reg.R24: if an ecception happens (fatal problem), value of the GbIC R24 register; 0, otherwise; 4th SystemInfo (two words field) = supplementary_data_info.reg.CTR: if an ecception happens (fatal problem), value of the GbIC CTR register; 0, otherwise. see previous description. 1st SystemInfo (two words field) = incident.location_reference.task: task where the fatal or critical problem happens; 2nd SystemInfo (two words field) = supplementary_data_info.reg.R9: if an ecception happens (fatal problem), value of the GbIC R9 register; 0, otherwise; 3rd SystemInfo (two words field) = supplementary_data_info.reg.R25: if an ecception happens (fatal problem), value of the GbIC R25 register; 0, otherwise; 4th SystemInfo (two words field): not used. see previous description. 1st SystemInfo (two words field) = incident.location_reference.module: module where the fatal or critical problem happens; 2nd SystemInfo (two words field) = supplementary_data_info.reg.R10: if an ecception happens (fatal problem), value of the GbIC R10 register; 0, otherwise; 3rd SystemInfo (two words field) = supplementary_data_info.reg.R26: if an ecception happens (fatal problem), value of the GbIC R26 register; 0, otherwise; 4th SystemInfo (two words field): not used. see previous description. 1st SystemInfo (two words field) = incident.location_reference.procedure: procedure where the fatal or critical incident happens; 2nd SystemInfo (two words field) = supplementary_data_info.reg.R11: if an ecception happens (fatal problem), value of the GbIC R11 register; 0, otherwise; 3rd SystemInfo (two words field) = supplementary_data_info.reg.R27: if an ecception happens (fatal problem), value of the GbIC R27 register; 0, otherwise; 4th SystemInfo (two words field): not used. see previous description. 1st SystemInfo (two words field) = incident.location_reference.reporting_point: reporting point where the the fatal or critical incident happens; 2nd SystemInfo (two words field) = supplementary_data_info.reg.R12: if an ecception happens (fatal problem), value of the GbIC R12 register; 0, otherwise; 3rd SystemInfo (two words field) = supplementary_data_info.reg.R28: if an ecception happens (fatal problem), value of the GbIC R28 register; 0, otherwise; 4th SystemInfo (two words field): not used. see previous description. 1st SystemInfo (two words field) = incident.location_reference.PSOS_error_code: value of the global variable, with the last error, occurred during a psos system call; 2nd SystemInfo (two words field) = supplementary_data_info.reg.R13: if an ecception happens (fatal problem), value of the GbIC R13 register; 0, ot herwise; 3rd SystemInfo (two words field) = supplementary_data_info.reg.R29: if an ecception happens (fatal problem), value of the GbIC R29 register; 0, otherwise; 4th SystemInfo (two words field): not used.
787

A30808-X3247-K240-3-7619

Outputs OML:BSC

Base Station Controller

20 = 21 =

22 = 23 =

24 = 25 =

26 = 27 =

28 = 29 =

30 = 31 =

32 =

see previous description. 1st SystemInfo (two words field) = incident.location_reference.MBLK_error_code: value of the global variable, with the last error, occurred during the mblks management; 2nd SystemInfo (two words field) = supplementary_data_info.reg.R14: if an ecception happens (fatal problem), value of the GbIC R14 register; 0, otherwise; 3rd SystemInfo (two words field) = supplementary_data_info.reg.R30: if an ecception happens (fatal problem), value of the GbIC R30 register; 0, otherwise; 4th SystemInfo (two words field): not used. see previous description. 1st SystemInfo (two words field) = incident.location_reference.RTN_error_code: value of the global variable, with the last error occurred in the InterProcessor routines; 2nd SystemInfo (two words field) = supplementary_data_info.reg.R15: if an ecception happens (fatal problem), value of the GbIC R15 register; 0, otherwise; 3rd SystemInfo (two words field) = supplementary_data_info.reg.R31: if an ecception happens (fatal problem), value of the GbIC R31 register; 0, otherwise; 4th SystemInfo (two words field): not used. see previous description. 1st SystemInfo (two words field) = supplementary_data_info.reg.R0: if an ecception happens (fatal problem), value of the GbIC R0 register; else, if the incident.location_reference.subsystem is the PhysicalBearer (e_phpi), it is a psos error, or an error code defined in the file phpi.h, else 0; 2nd SystemInfo (two words field) = supplementary_data_info.reg.R16: if an ecception happens (fatal problem), value of the GbIC R16 register; 0, otherwise; 3rd SystemInfo (two words field) = supplementary_data_info.reg.CR: if an ecception happens (fatal problem), value of the GbIC CR register; 0, otherwise; 4th SystemInfo (two words field): not used. see previous description. 1st SystemInfo (two words field) = supplementary_data_info.reg.R1: if an ecception happens (fatal problem), value of the GbIC R1 register; 0, otherwise; 2nd SystemInfo (two words field)supplementary_data_info.reg.R17: if an ecception happens (fatal problem), value of the GbIC R17 register; 0, otherwise; 3rd SystemInfo (two words field) = supplementary_data_info.reg.SPR0: if an ecception happens (fatal problem), value of the GbIC SPR0 register; 0, otherwise; 4th SystemInfo (two words field): not used. see previous description. 1st SystemInfo (two words field) = supplementary_data_info.reg.R2: if an ecception happens (fatal problem), value of the GbIC R2 register; 0, otherwise; 2nd SystemInfo (two words field) = supplementary_data_info.reg.R18: if an ecception happens (fatal problem), value of the GbIC R18 register; 0, otherwise; 3rd SystemInfo (two words field) = supplementary_data_info.reg.SPR1: if an ecception happens (fatal problem), value of the GbIC SPR1 register; 0, otherwise; 4th SystemInfo (two words field): not used. see previous description. 1st SystemInfo (two words field) = supplementary_data_info.reg.R3: if an ecception happens (fatal problem), value of the GbIC R3 register; 0, otherwise; 2nd SystemInfo (two words field) = supplementary_data_info.reg.R19: if an ecception happens (fatal problem), value of the GbIC R19 register; 0, otherwise; 3rd SystemInfo (two words field) = supplementary_data_info.reg.LR: if an ecception happens (fatal problem), value of the GbIC LR register; 0, otherwise; 4th SystemInfo (two words field): not used. see previous description.

Case of XXXX = 4503 MDHXXDCSA sysinfo description : See also the first case description (subdivision is done for readibility aims only).
788 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

When a "GBIC SW Problem" occurs, it is always followed by other three "GBIC SW Problem" SystemInfo. For this reason the description of each field shows the meaning of the field in every SystemInfo. The first word of the First System Information is the Error Type. . 1= 1st SystemInfo (one word field): 1080, GBIC INITIALISATION FAILED 2st SystemInfo (two words field): init_diag.point_of_failure.procedure: procedure where the incident occurrs; 3rd SystemInfo (one word field): First Byte = init_diag.supplementary_data[44]: 45-th byte of a not used vector; Second Byte = init_diag.supplementary_data[45]: 46-th byte of a not used vector. 2= 1st SystemInfo (one word field): 1366, PPCU Agent Device Controller Originator 2nd SystemInfo: see previous description; 3rd SystemInfo (one word field): First Byte = init_diag.supplementary_data[46]: 47-th byte of a not used vector; Second Byte = init_diag.supplementary_data[47]: 48-th byte of a not used vector. 3= 1st SystemInfo (one word field): First Byte = init_diag.name[0]: first byte of the string with the name of the function where the incident occurs; Second Byte = init_diag.name[1]: second byte of the string with the name of the function where the incident ocuurs; 2nd SystemInfo (two words field): init_diag.point_of_failure.reporting_point: identificator of the point of the procedure where the incident occurrs; 3rd SystemInfo (one word field): First Byte = init_diag.supplementary_data[48]: 49-th byte of a not used vector; Second Byte = init_diag.supplementary_data[49]: 50-th byte of a not used vector. 4= 1st SystemInfo (one word field): First Byte = init_diag.name[2]: third byte of the string with the name of the function where the incident occurs; Second Byte = init_diag.name[3]: fourth byte of the string with the name of the function where the incident ocuurs; 2nd SystemInfo: see previous description; 3rd SystemInfo (one word field): First Byte = init_diag.supplementary_data[50]: 51-th byte of a not used vector; Second Byte = init_diag.supplementary_data[51]: 52-th byte of a not used vector. 5= 1st SystemInfo (one word field): First Byte = init_diag.name[4]: 6-th byte of the string with the name of the function where the incident occurs; Second Byte = init_dia.name[5]: 7-th byte of the string with the name of the function where the incident ocuurs; 2nd SystemInfo (two words field): init_diag.point_of_failure.PSOS_error_code: value of the global variable with the last error, occurred during a psos call; 3rd SystemInfo (one word field): First Byte = init_diag.supplementary_data[52]: 53-th byte of a not used vector; Second Byte = init_diag.supplementary_data[53]: 54-th byte of a not used vector. 6= 1st SystemInfo (one word field): First Byte = init diag.name[6]: 7-th byte of the string with the name of
A30808-X3247-K240-3-7619 789

Outputs OML:BSC

Base Station Controller

7=

8=

9=

10 =

the function where the incident occurs; Second Byte = init_diag.name[7]: 8-th byte of the string with the name of the function where the incident ocuurs; 2nd SystemInfo: see previous description; 3rd SystemInfo (one word field): First Byte = init_diag.supplementary_data[54]: 55-th byte of a not used vector; Second Byte = init_diag.supplementary_data[55]: 56-th byte of a not used vector. 1st SystemInfo (one word field): First Byte = init_diag.name[8]: 10-th byte of the string with the name of the function where the incident occurs; Second Byte = init_diag.name[9]: 11-th byte of the string with the name of the function where the incident occurs; 2nd SystemInfo (two words field): init_diag.point_of_failure.MBLK_error_code: value of the global variable with the last error, occurred during the mblks management; 3rd SystemInfo (one word field): First Byte = init_diag.supplementary_data[56]: 57-th byte of a not used vector; Second Byte = init_diag.supplementary_data[57]: 58-th byte of a not used vector. 1st SystemInfo (one word field): First Byte = init_diag.na]: 11-th byte of the string with the name of the function where the incident occurs; Second Byte = init_diag.name[11]: 12-th byte of the string with the name of the function where the incident ; 2nd SystemInfo: see previous description; 3rd SystemInfo (one word field): First Byte = init_diag.supplementary_data[58]: 59-th byte of a not used vector; Second Byte = init_diag.supplementary_data[59]: 60-th byte of a not used vector. 1st SystemInfo (one word field): First Byte = init_diag.name[12]: 13-th byte of the string with the name of the function where the incident occurs; Second Byte = init_diag.name[13]: 14-th byte of the string with the name of the function where the incident occurs; 2nd SystemInfo (two words field): init_diag.point_of_failure.RTN_error_code: value of the global variable with the last error, occurred in the InterProcessor procedures; 3rd SystemInfo (one word field): not used. 1st SystemInfo (one word field): First Byte = init_diag.name[14]: 15-th byte of the string with the name of the function where the incident occurs; Second Byte = init_diag.name[15]: 17-th byte of the string with the name of the function where the incident occurs; 2nd SystemInfo: see previous description; 3rd SystemInfo (one word field): not used. 1st SystemInfo (one word field): First Byte = init_diag.name[16]: 17-th byte of the string with the name of the function where the incident occurs; Second Byte = init_diag.name[17]: 18-th byte of the string with the name of the function where the incident occurs; 2nd SystemInfo (one word field): First Byte = init_diag.supplementary_data[0]: fisrt byte of the string with the name of the function where the incident occurs; Second Byte = init diag.supplementary data[1]: second byte of the
A30808-X3247-K240-3-7619

11 =

790

Base Station Controller

Outputs OML:BSC

string with the name of the function where the incident occurs; 3rd SystemInfo (one word field): not used. 12 = 1st SystemInfo (one word field): First Byte = init_diag.name[18]: 19-th byte of the string with the name of the function where the incident occurs; Second Byte = init_diag.name[19]: 20-th byte of the string with the name of the function where the incident occurs; 2st SystemInfo (one word field): First Byte = init_diag.supplementary_data[2]: third byte of the string with the name of the function where the incident occurs; Second Byte = init_diag.supplementary_data[3]: fourth byte of the string with the name of the function where the incident occurs; 3rd SystemInfo (one word field): not used. 1st SystemInfo (one word field): First Byte = init_diag.name[20]: 21-th byte of the string with the name of the function where the incident occurs; Second Byte = init_diag.name[21]: 22-th byte of the string with the name of the function where the incident occurs; 2nd SystemInfo (one word field): First Byte = init_diag.supplementary_data[4]: 5-th byte of a not used vector; Second Byte = init_diag.supplementary_data[5]: 6-th byte of a not used vector; 3rd SystemInfo (one word field): not used. 1st SystemInfo (one word field): First Byte = init_diag.name[22]: 23-th byte of the string with the name of the function where the incident occurs; Second Byte = init_diag.name[23]: 24-th byte of the string with the name of the function where the incident occurs; 2nd SystemInfo (one word field): First Byte = init_diag.supplementary_data[6]: 7-th byte of a not used vector; Second Byte = init_diag.supplementary_data[7]: 8-th byte of a not used vector; 3rd SystemInfo (one word field): not used. 1st SystemInfo (one word field): First Byte = init_diag.reason_for_failure[0]: first byte of the string with the incident reason; Second Byte = init_diag.reason_for_failure[1]: second byte of the string with the incident reason; 2nd SystemInfo (one word field): First Byte = init_diag.supplementary_data[8]: 9-th byte of a not used vector; Second Byte = init_diag.supplementary_data[9]: 10-th byte of a not used vector; 3rd SystemInfo (one word field): not used. 1st SystemInfo (one word field): First Byte = init_diag.reason_for_failure[2]: third byte of the string with the incident reason; Second Byte = init_diag.reason_for_failure[3]: fouth byte of the string with the incident reason; 2nd SystemInfo (one word field):
791

13 =

14 =

15 =

16 =

A30808-X3247-K240-3-7619

Outputs OML:BSC

Base Station Controller

First Byte = init_diag.supplementary_data[10]: 11-th byte of a not used vector; Second Byte = init_diag.supplementary_data[11]: 12-th byte of a not used vector; 3rd SystemInfo (one word field): not used. 17 = 1st SystemInfo (one word field): First Byte = init_diag.reason_for_failure[4]: 5-th byte of the string with the incident reason; Second Byte = init_diag.reason_for_failure[5]: 6-th byte of the string with the incident reason; 2nd SystemInfo (one word field): First Byte = init_diag.supplementary_data[12]: 13-th byte of a not used vector; Second Byte = init_diag.supplementary_data[13]: 14-th byte of a not used vector; 3rd SystemInfo (one word field): not used. 1st SystemInfo (one word field): First Byte = init_diag.reason_for_failure[6]: 8-th byte of the string with the incident reason; Second Byte = init_diag.reason_for_failure[7]: 9-th byte of the string with the incident reason; 2nd SystemInfo (one word field): First Byte = init_diag.supplementary_data[14]: 15-th byte of a not used vector; Second Byte = init_diag.supplementary_data[15]: 16-th byte of a not used vector; 3rd SystemInfo (one word field): not used. 1st SystemInfo (one word field): First Byte = init_diag.reason_for_failure[8]: 9-th byte of the string with the name of the function where the incident occurs; Second Byte = init_diag.reason_for_failure[9]: 11-th byte of the string with the name of the function where the incident occurs; 2nd SystemInfo (one word field): First Byte = init_diag.supplementary_data[16]: 17-th byte of a not used vector; Second Byte = init_diag.supplementary_data[17]: 18-th byte of a not used vector; 3rd SystemInfo (one word field): not used. 1st SystemInfo (one word field): First Byte = init_diag.reason_for_failure[10]: 11-th byte of the string with the name of the function where the incident occurs; Second Byte = init_diag.reason_for_failure[11]: 12-th byte of the string with the name of the function where the incident occurs; 2nd SystemInfo (one word field): First Byte = init_diag.supplementary_data[18]: 19-th byte of a not used vector; Second Byte = init_diag.supplementary_data[19]: 20-th byte of a not used vector; 3rd SystemInfo (one word field): not used. 1st SystemInfo (one word field): First Byte = init_diag.reason_for_failure[12]: 13-th byte of the string with the name of the function where the incident occurs;
A30808-X3247-K240-3-7619

18 =

19 =

20 =

21 =

792

Base Station Controller

Outputs OML:BSC

Second Byte = init_diag.reason_for_failure[13]: 14-th byte of the string with the name of the function where the incident occurs; 2nd SystemInfo (one word field): First Byte = init_diag.supplementary_data[20]: 21-th byte of a not used vector; Second Byte = init_diag.supplementary_data[21]: 22-th byte of a not used vector; 3rd SystemInfo (one word field): not used. 22 = 1st SystemInfo (one word field): First Byte = init_diag.reason_for_failure[14]: 15-th byte of the string with the name of the function where the incident occurs; Second Byte = init_diag.reason_for_failure[15]: 16-th byte of the string with the name of the function where the incident occurs; 2nd SystemInfo (one word field): First Byte = init_diag.supplementary_data[22]: 23-th byte of a not used vector; Second Byte = init_diag.supplementary_data[23]: 24-th byte of a not used vector; 3rd SystemInfo (one word field): not used. 1st SystemInfo (one word field): First Byte = init_diag.reason_for_failure[16]: 17-th byte of the string with the name of the function where the incident occurs; Second Byte = init_diag.reason_for_failure[17]: 18-th byte of the string with the name of the function where the incident occurs; 2nd SystemInfo (one word field): First Byte = init_diag.supplementary_data[24]: 24-th byte of a not used vector; Second Byte = init_diag.supplementary_data[25]: 25-th byte of a not used vector; 3rd SystemInfo (one word field): not used. 1st SystemInfo (one word field): First Byte = init_diag.reason_for_failure[18]: 19-th byte of the string with the name of the function where the incident occurs; Second Byte = init_diag.reason_for_failure[19]: 20-th byte of the string with the name of the function where the incident occurs; 2nd SystemInfo (one word field): First Byte = init_diag.supplementary_data[26]: 27-th byte of a not used vector; Second Byte = init_diag.supplementary_data[27]: 28-th byte of a not used vector; 3rd SystemInfo (one word field): not used. 1st SystemInfo (two words field): init_diag.point_of_failure.subsytem: system where the incident occurs; 2nd SystemInfo (one word field): First Byte = init_diag.supplementary_data[28]: 29-th byte of a not used vector; Second Byte = init_diag.supplementary_data[29]: 30-th byte of a not used vector; 3rd SystemInfo (one word field): not used. 1st SystemInfo: see previous description; 2nd SystemInfo (one word field): First Byte = init diag.supplementary data[30]: 31-th byte of a not used
793

23 =

24 =

25 =

26 =

A30808-X3247-K240-3-7619

Outputs OML:BSC

Base Station Controller

vector; Second Byte = init_diag.supplementary_data[31]: 32-th byte of a not used vector. 3rd SystemInfo (one word field): not used. 27 = 1st SystemInfo (two words field): init_diag.point_of_failure.sw_component: component where the incident occurs; 2nd SystemInfo (one word field): First Byte = init_diag.supplementary_data[32]: 33-th byte of a not used vector; Second Byte = init_diag.supplementary_data[33]: 34-th byte of a not used vector; 3rd SystemInfo (one word field): not used. 1st SystemInfo: see previous description; 2nd SystemInfo (one word field): First Byte = init_diag.supplementary_data[34]: 35-th byte of a not used vector; Second Byte = init_diag.supplementary_data[35]: 36-th byte of a not used vector; 3rd SystemInfo (one word field): not used. 29 = 1st SystemInfo (two words field): init_diag.point_of_failure.task: task where the incident occurs; 2nd SystemInfo (one word field): First Byte = init_diag.supplementary_data[36]: 36-th byte of a not used vector; Second Byte = init_diag.supplementary_data[37]: 37-th byte of a not used vector; 3rd SystemInfo (one word field): not used. 1st SystemInfo: see previous description; 2nd SystemInfo (one word field): First Byte = init_diag.supplementary_data[38]: 39-th byte of a not used vector; Second Byte = init_diag.supplementary_data[39]: 40-th byte of a not used vector; 3rd SystemInfo (one word field): not used. 31 = 1st SystemInfo (two words field): init_diag.point_of_failure.module: module where the incident occurs; 2nd SystemInfo (one word field): First Byte = init_diag.supplementary_data[40]: 41-th byte of a not used vector; Second Byte = init_diag.supplementary_data[41]: 42-th byte of a not used vector; 3rd SystemInfo (one word field): not used. 1st SystemInfo: see previous description; 2nd SystemInfo (one word field): First Byte = init_diag.supplementary_data[42]: 43-th byte of a not used vector; Second Byte = init_diag.supplementary_data[43]: 44-th byte of a not used vector; 3rd SystemInfo (one word field): not used. ##fine##
794 A30808-X3247-K240-3-7619

28 =

30 =

32 =

Base Station Controller

Outputs OML:BSC

SYSINFO_ID: 075
SYSTEM INFO REPORT: Originator:

PCUC HW PROBLEM DIAGNOSTIC REQUIRED


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4503 MDHXXDCSA sysinfo description : This system info is issued when a periodic fault detection activity, scheduled by PPCU Device Handler, detects on PCUC-MPCC DUAM some information written by PPCU Agent task and concerning a HW problem on PCUC processor (belonging to PPCU card). Word 1 is the Error Identifier 1 = 1004 , MPCC PPCU DUAM PARITY ERROR 2 = 136A, PPCU Agent Device Controller Originator 3 = Not Used 4 = Not Used 5 = Not Used 6 = Not Used 7 = Not Used 8 = Not Used 9 = Not Used 10 = Not Used 11 = Not Used 12 = Not Used 13 = Not Used 14 = Not Used 15 = Not Used 16 = Not Used 17 = Not Used 18 = Not Used 19 = Not Used 20 = Not Used 21 = Not Used 22 = Not Used 23 = Not Used 24 = Not Used 25 = Not Used 26 = Not Used 27 = Not Used 28 = Not Used 29 = Not Used 30 = Not Used 31 = Not Used 32 = Not Used

A30808-X3247-K240-3-7619

795

Outputs OML:BSC

Base Station Controller

Case of XXXX = 4503 MDHXXDCSA sysinfo description : See also the previous case description (this subdivision is done for readibility aims only). Word 1 is the Error Identifier 1 = 1008, TDPC PPCU DUAM PARITY ERROR 2 = 136A, PPCU Agent Device Controller Originator 3 = Not Used 4 = Not Used 5 = Not Used 6 = Not Used 7 = Not Used 8 = Not Used 9 = Not Used 10 = Not Used 11 = Not Used 12 = Not Used 13 = Not Used 14 = Not Used 15 = Not Used 16 = Not Used 17 = Not Used 18 = Not Used 19 = Not Used 20 = Not Used 21 = Not Used 22 = Not Used 23 = Not Used 24 = Not Used 25 = Not Used 26 = Not Used 27 = Not Used 28 = Not Used 29 = Not Used 30 = Not Used 31 = Not Used 32 = Not Used Case of XXXX = 4503 MDHXXDCSA sysinfo description : See also the first case description (this subdivision is done for readibility aims only). Word 1 is the Error Identifier An interrupt occured and the system as a defense action is trying to delete the current task when a second interrupt occurs generating a task abort loop. The informations about the current task are shown in the following messages. 1 = 18, INVALID POINTER BRING UP 2 = 3B6, UOSKNMSEH Pcuc Originator 3 = 1F, BRING UP REQUIRED 4 = Not Used 5 = Not Used 6 = Not Used 7 = Not Used 8 = Not Used 9 = Not Used 10 = Not Used 11 = Not Used
796 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

12 = 13 = 14 = 15 = 16 = 17 = 18 = 19 = 20 = 21 = 22 = 23 = 24 = 25 = 26 = 27 = 28 = 29 = 30 = 31 = 32 =

Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used

Case of XXXX = 4503 MDHXXDCSA sysinfo description : See also the first case description (this subdivision is done for readibility aims only). Word 1 is the Error Identifier. A sequence of a Task Prime Initializations in a too short interval. The level of the initialization is upgraded to BringUp 1= 2= 3= 4= 5= 6= 7= 8= 9= 10 = 11 = 12 = 13 = 14 = 15 = 16 = 17 = 18 = 19 = 20 = 21 = 22 = 23 = 24 = 25 = 26 = 27 = 36, PRIME TO BRINGUP INIT 3B6, UOSKNMSEH Ppcu Originator 22, 0x22 RTE+ internal code error (for developer's use) Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used
797

A30808-X3247-K240-3-7619

Outputs OML:BSC

Base Station Controller

28 = 29 = 30 = 31 = 32 =

Not Used Not Used Not Used Not Used Not Used

Case of XXXX = 4503 MDHXXDCSA sysinfo description : See also the first case description (this subdivision is done for readibility aims only). Word 1 is the Error Identifier. This System Information occurs when a Memory Pool inconsistency is detected by the Operating System after a task deletion 1 = EEEE, RTE INTIALIZATION REQUIRED 2 = 3B6, UOSKNMSEH Ppcu Originator 3 = 29, RTE+ internal code error (for developer's use) 4 = Not Used 5 = Not Used 6 = Not Used 7 = Not Used 8 = Not Used 9 = Not Used 10 = Not Used 11 = Not Used 12 = Not Used 13 = Not Used 14 = Not Used 15 = Not Used 16 = Not Used 17 = Not Used 18 = Not Used 19 = Not Used 20 = Not Used 21 = Not Used 22 = Not Used 23 = Not Used 24 = Not Used 25 = Not Used 26 = Not Used 27 = Not Used 28 = Not Used 29 = Not Used 30 = Not Used 31 = Not Used 32 = Not Used Case of XXXX = 4503 MDHXXDCSA sysinfo description : See also the first case description (this subdivision is done for readibility aims only). Word 1 is the Error Identifier. The safe function is unable to operate during a task abort. 1 = 1F, SYSTEM CALL UNSUCCESSFUL BU INIT 2 = Pcuc Originator 3 = Source module 4 = Source code line 5 = Pool type requested
798 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

6= 7= 8= 9= 10 = 11 = 12 = 13 = 14 = 15 = 16 = 17 = 18 = 19 = 20 = 21 = 22 = 23 = 24 = 25 = 26 = 27 = 28 = 29 = 30 = 31 = 32 =

Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used

Case of XXXX = 4503 MDHXXDCSA sysinfo description : See also the first case description (this subdivision is done for readibility aims only). Word 1 is the Error Identifier. This error is generated every time it isn't possible to grant a request of memory. 1 = 31, MEMORY_OVERFLOW 2 = 3B6, OSKNMSEH Ppcu Originator 3 = 0x11, MEM_OVF, 0x12, MEM_BAD_ADDR, 0x13, MSG_OVF 4 = Not Used 5 = Not Used 6 = Not Used 7 = Not Used 8 = Not Used 9 = Not Used 10 = Not Used 11 = Not Used 12 = Not Used 13 = Not Used 14 = Not Used 15 = Not Used 16 = Not Used 17 = Not Used 18 = Not Used 19 = Not Used 20 = Not Used 21 = Not Used 22 = Not Used 23 = Not Used
A30808-X3247-K240-3-7619 799

Outputs OML:BSC

Base Station Controller

24 = 25 = 26 = 27 = 28 = 29 = 30 = 31 = 32 =

Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used

Case of XXXX = 4503 MDHXXDCSA sysinfo description : See also the first case description (this subdivision is done for readibility aims only). Word 1 is the Error Identifier. This error is generated every time it isn't possible to grant a request of blocks of memory from the dynamic memory pools. 1 = 32, DYNAMIC_MEMORY_POOL_OVERFLOW 2 = 3B6, OSKNMSEH Ppcu Originator 3= 0 POOL_TR, 1 POOL_TC, 2 POOL_MB, 3 POOL_SEM, 4 POOL_STK, 5 POOL_HDR, 6 POOL_DATA_MSG, 7 POOL_MSG_0, 8 POOL_MSG_1, 9 POOL_MSG_2, 0x0A POOL_MSG_3 0x0B POOL_MSG_4 4 = number of overflows in the pool 5 = Not Used 6 = Not Used 7 = Not Used 8 = Not Used 9 = Not Used 10 = Not Used 11 = Not Used 12 = Not Used 13 = Not Used 14 = Not Used 15 = Not Used 16 = Not Used 17 = Not Used 18 = Not Used 19 = Not Used 20 = Not Used 21 = Not Used 22 = Not Used 23 = Not Used 24 = Not Used 25 = Not Used 26 = Not Used 27 = Not Used 28 = Not Used 29 = Not Used
800 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

30 = 31 = 32 =

Not Used Not Used Not Used

Case of XXXX = 4503 MDHXXDCSA sysinfo description : See also the first case description (this subdivision is done for readibility aims only). Word 1 is the Error Identifier A task or a scan work function caused an exception and the system deletes it; if the Entry point is equal to zero the activity which caused the interrupt is a scan work function.A RTE System Info Report is related to this message. For more details, please refers to ANNEX E. 1 = 33, DELETED_CURRENT_TASK 2 = 3B6, OSKNMSEH Ppcu Originator 3 = 0x14 DEL CURR TSK 0x48 DEL SWF TSK 4 = Task Entry Point (selector) 5 = Task Entry Point (offset) 6 = Interrupt Type 7 = Processor Register (16bit): CS 8 = Processor Register (32bit): IP 9 = Processor Register (32bit): IP 10 = Callstack (4 entries; call reverse order: first entry = last call) 11 = Callstack 12 = Callstack 13 = Callstack 14 = Callstack 15 = Callstack 16 = Callstack 17 = Callstack 18 = Not Used 19 = Not Used 20 = Not Used 21 = Not Used 22 = Not Used 23 = Not Used 24 = Not Used 25 = Not Used 26 = Not Used 27 = Not Used 28 = Not Used 29 = Not Used 30 = Not Used 31 = Not Used 32 = Not Used Case of XXXX = 4503 MDHXXDCSA sysinfo description : See also the first case description (this subdivision is done for readibility aims only). First SysInfo First Word is the Error Identifier 1= 2= 3= 2001, PPCU HARDWARE EXCEPTION 1369, UDHPDEXHN Originator
801

A30808-X3247-K240-3-7619

Outputs OML:BSC

Base Station Controller

4= 5= 6= 7= 8= 9= 10 = 11 = 12 = 13 = 14 = 15 = 16 = 17 = 18 = 19 = 20 = 21 = 22 = 23 = 24 = 25 = 26 = 27 = 28 = 29 = 30 = 31 = 32 =

Originator Originator Originator Time Stamp Time Stamp Time Stamp Time Stamp Lat Position, Interrupt Counter Nmi counters for both initialization level Exception counters for both initialization level Extended Originator (Low) Extended Originator (Hight)) Last PIIX4 address = (Function 1) 0x6-07h - PCI Device Status Register, Last PIIX4 address = 0x61 - NMI Status and Control Register Last PIC In Service, Last ISA BUS address = 0x4020 - Confstatus Last Qspan Pci Control Status , Last PIC In Service Last PIC In Service, Last Qspan Pci-Qbus Error Control Last Qspan Pci-Qbus Error Control, Last Qspan Pci Control Status Last Qspan Pci-Qbus Error Control,Last Qspan Pci-Qbus Error Control Last Qspan data Error Log, Last Qspan Pci-Qbus Error Control Last Qspan data Error Log, Last Qspan data Error Log Last Qspan address Error Log, Last Qspan data Error Log Last Qspan address Error Log, Last Qspan address Error Log Last Qspan Interrupt Status, Last Qspan address Error Log Last Qspan Interrupt Status, Last Qspan Interrupt Status Last ISA BUS address = 0xFF30 - Last DSP Reset Status, Qspan Interrupt Status Spare, Time Stamp Exc PIIX4 address = (Function 1) 0x6-07h - PCI Device Status Register, Exc PIIX4 address = 0x61 - NMI Status and Control Register Exc PIC In Service, Exc ISA BUS address = 0x4020 - Confstatus Exc Qspan Pci Control Status , Exc PIC In Service

Case of XXXX = 4503 MDHXXDCSA sysinfo description : See also the first case description (this subdivision is done for readibility aims only). Second SysInfo 1 = Exc PIC In Service, Exc Qspan Pci-Qbus Error Control 2 = Exc Qspan Pci-Qbus Error Control, Exc Qspan Pci Control Status 3 = Exc Qspan Pci-Qbus Error Control, Exc Qspan Pci-Qbus Error Control 4 = Exc Qspan data Error Log, Exc Qspan Pci-Qbus Error Control 5 = Exc Qspan data Error Log, Exc Qspan data Error Log 6 = Exc Qspan address Error Log, Exc Qspan data Error Log 7 = Exc Qspan address Error Log, Exc Qspan address Error Log 8 = Exc Qspan Interrupt Status, Exc Qspan address Error Log 9 = Exc Qspan Interrupt Status, Exc Qspan Interrupt Status 10 = Exc ISA BUS address = 0xFF30 - Exc DSP Reset Status, Qspan Interrupt Status 11 = Exception Type: 0=Exception, 1=NMI, Error Funtional Area Identifier: 0=UNKNOW, 1=PPCU, 2=MPC860, 3=ISA Bridge 4=Qspan Bridge, 5=DSP, 6=TDCP Duam, 7=MPCC Duam 12 = 13 = 14 = 15 = 16 = 17 =
802

Qspan address Error Log Qspan address Error Log Qspan data Error Log Qspan data Error Log IP address IP address
A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

18 = OS data. 19 = OS data. 20 = OS data. 21 = OS data. 22 = OS data. 23 = OS data. 24 = OS data. 25 = OS data. 26 = OS data. 27 = OS data. 28 = OS data. 29 = OS data. 30 = OS data. 31 = OS data. 32 = Not used ##fine##

A30808-X3247-K240-3-7619

803

Outputs OML:BSC

Base Station Controller

SYSINFO_ID: 076
SYSTEM INFO REPORT: Originator:

PCUC SW PROBLEM
<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4503 MDHXXDCSA sysinfo description : This system info is issued when a periodic check performed by PPCU Device Handler on MPCC-PCUC DUAM detects some information written by PPCU Agent task and concerning SW problems on PCUC processor (belonging to PPCU card). Word 1 is the Error Identifier An interrupt occured and the system as a defense action is trying to delete the current task when a second interrupt occurs generating a task abort loop. The informations about the current task are shown in the following messages. 1= 2= 3= 4= 5= 6= 7= 8= 9= 10 = 11 = 12 = 13 = 14 = 15 = 16 = 17 = 18 = 19 = 20 = 21 = 22 = 23 = 24 = 25 = 26 = 27 = 28 = 29 =
804

18, INVALID POINTER BRING UP 3B6, UOSKNMSEH Pcuc Originator 1F, RTE+ internal code error (for developer's use) Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used
A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

30 = 31 = 32 =

Not Used Not Used Not Used

Case of XXXX = 4503 MDHXXDCSA sysinfo description : See also the first case description (subdivision is done for readibility aims only). Word 1 is the Error Identifier A sequence of a Task Prime Initializations in a too short interval. The level of the initialization is upgraded to BringUp 1= 2= 3= 4= 5= 6= 7= 8= 9= 10 = 11 = 12 = 13 = 14 = 15 = 16 = 17 = 18 = 19 = 20 = 21 = 22 = 23 = 24 = 25 = 26 = 27 = 28 = 29 = 30 = 31 = 32 = 36, PRIME TO BRINGUP INIT 3B6, UOSKNMSEH Ppcu Originator 22, RTE+ internal code error (for developer's use) Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used

Case of XXXX = 4503 MDHXXDCSA sysinfo description : See also the first case description (subdivision is done for readibility aims only). Word 1 is the Error Identifier This SystemInformation occurs when a Memory Pool inconsistency is detected by the Operating System after a task deletion 1= 2= 3= EEEE, RTE INITIALIZATION REQUEST 3B6, UOSKNMSEH Ppcu Originator 22, RTE+ internal code error (for developer's use)
805

A30808-X3247-K240-3-7619

Outputs OML:BSC

Base Station Controller

4= 5= 6= 7= 8= 9= 10 = 11 = 12 = 13 = 14 = 15 = 16 = 17 = 18 = 19 = 20 = 21 = 22 = 23 = 24 = 25 = 26 = 27 = 28 = 29 = 30 = 31 = 32 =

Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used No tUsed

Case of XXXX = 4503 MDHXXDCSA sysinfo description : See also the first case description (subdivision is done for readibility aims only). Word 1 is the Error Identifier The safe function is unable to operate during a task abort. 1= 2= 3= 4= 5= 6= 7= 8= 9= 10 = 11 = 12 = 13 = 14 = 15 = 16 = 17 = 18 = 19 = 20 =
806

1F, SYSTEM CALL UNSUCCESSFUL BU INIT Pcuc Originator Source module Source code line Pool type requested Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used
A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

21 = 22 = 23 = 24 = 25 = 26 = 27 = 28 = 29 = 30 = 31 = 32 =

Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used

Case of XXXX = 4503 MDHXXDCSA sysinfo description : See also the first case description (subdivision is done for readibility aims only). Word 1 is the Error Identifier This error is generated every time it isn't possible to grant a request of memory. 1= 2= 3= 4= 5= 6= 7= 8= 9= 10 = 11 = 12 = 13 = 14 = 15 = 16 = 17 = 18 = 19 = 20 = 21 = 22 = 23 = 24 = 25 = 26 = 27 = 28 = 29 = 30 = 31 = 32 = 31, MEMORY_OVERFLOW 3B6, OSKNMSEH Ppcu Originator 0x11, MEM_OVF, 0x12, MEM_BAD_ADDR, 0x13, MSG_OVF Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used

Case of XXXX = 4503 MDHXXDCSA sysinfo description : See also the first case description (subdivision is done for readibility aims only).
A30808-X3247-K240-3-7619 807

Outputs OML:BSC

Base Station Controller

Word 1 is the Error Identifier This error is generated every time it isn't possible to grant a request of blocks of memory from the dynamic memory pools. 1= 2= 3= 32, DYNAMIC_MEMORY_POOL_OVERFLOW 3B6, OSKNMSEH Ppcu Originator 0 POOL_TR, 1 POOL_TC, 2 POOL_MB, 3 POOL_SEM, 4 POOL_STK, 5 POOL_HDR, 6 POOL_DATA_MSG, 7 POOL_MSG_0, 8 POOL_MSG_1, 9 POOL_MSG_2, 0x0A POOL_MSG_3 0x0B POOL_MSG_4 number of overflows in the pool Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used

4= 5= 6= 7= 8= 9= 10 = 11 = 12 = 13 = 14 = 15 = 16 = 17 = 18 = 19 = 20 = 21 = 22 = 23 = 24 = 25 = 26 = 27 = 28 = 29 = 30 = 31 = 32 =

Case of XXXX = 4503 MDHXXDCSA sysinfo description : See also the first case description (subdivision is done for readibility aims only). Word 1 is the Error Identifier A task or a scan work function caused an exception and the system deletes it; if the Entry point is equal to zero the activity which caused the interrupt is a scan work function.A RTE System Info Report is related to
808 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

this message. For more details, please refers to ANNEX E. 1= 2= 3= 33, DELETED_CURRENT_TASK 3B6, OSKNMSEH Ppcu Originator 0x14 DEL CURR TSK 0x48 DEL SWF TSK

4 = Task Entry Point (selector) 5 = Task Entry Point (offset) 6 = Interrupt Type 7 = Processor Register (16bit): CS 8 = Processor Register (32bit): IP 9 = Processor Register (32bit): IP 10 = Callstack (4 entries; call reverse order: first entry = last call) 11 = Callstack 12 = Callstack 13 = Callstack 14 = Callstack 15 = Callstack 16 = Callstack 17 = Callstack 18 = Not Used 19 = Not Used 20 = Not Used 21 = Not Used 22 = Not Used 23 = Not Used 24 = Not Used 25 = Not Used 26 = Not Used 27 = Not Used 28 = Not Used 29 = Not Used 30 = Not Used 31 = Not Used 32 = Not Used ##fine##

A30808-X3247-K240-3-7619

809

Outputs OML:BSC

Base Station Controller

SYSINFO_ID: 077
SYSTEM INFO REPORT: Originator:

GBIC NS-PROTOCOL FAILURE


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4953 TDHGPIHGB sysinfo description : This System Info Report maps a GbIC error event on BSC System Info Report in the following cases: NS Unblock procedure failed (OM_EVT_NS_UNBLOCK_FAIL), NS Block procedure failed (OM_EVT_NS_BLOCK_FAIL), NS Reset procedure failed (OM_EVT_NS_RESET_FAIL), NS Test procedure failed (OM_EVT_NS_TEST_FAIL), No alive NSVC available and consequent NS Block procedure aborted (OM_EVT_NS_BLOCK_ABORT), A NS-RESET PDU with invalid parameters has been received (OM_EVT_NS_RESET_INVALID), A NS-PDU with invalid NSVCI parameter has been received (OM_EVT_NSVC_UNKNOWN), An unexpected acknowledge NS-PDU has been received (OM_EVT_NS_ACK_UNEXPECTED), An invalid NS-PDU has been received (OM_EVT_INVALID_NS_PDU) 1 = GbIC ERROR CAUSE: 0x40 = OM_EVT_NS_UNBLOCK_FAIL 0x41 = OM_EVT_NS_BLOCK_FAIL 0x42 = OM_EVT_NS_RESET_FAIL 0x43 = OM_EVT_NS_TEST_FAIL 0x44 = OM_EVT_NS_BLOCK_ABORT 0x45 = OM_EVT_NS_RESET_INVALID 0x46 = OM_EVT_NSVC_UNKNOWN 0x47 = OM_EVT_NS_ACK_UNEXPECTED 0x48 = OM_EVT_INVALID_NS_PDU 2 = case ERROR CAUSE - OM_EVT_NS_BLOCK_FAIL: index of NSVC used for NS-BLOCK PDU (lower byte) index of NSVC to be blocked (higher byte) - OM_EVT_NS_RESET_INVALID: expected NSEI - OM_EVT_NSVC_UNKNOWN: received NSVCI - OM_EVT_INVALID_NS_PDU: NS-PDU dump 3 = case ERROR CAUSE - OM_EVT_NS_BLOCK_FAIL: cause of block procedure, i.e. CAUSE field in NS-BLOCK PDU (higher byte) - OM_EVT_NS_RESET_INVALID: expected NSVCI - OM_EVT_NSVC_UNKNOWN: PDU type - OM_EVT_NS_ACK_UNEXPECTED - OM_EVT_INVALID_NS_PDU: NS-PDU dump 4 = case ERROR CAUSE - OM_EVT_NS_RESET_INVALID: received NSEI - OM_EVT_INVALID_NS_PDU: NS-PDU dump 5 = case ERROR CAUSE - OM_EVT_NS_RESET_INVALID: received NSVCI
810 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

- OM_EVT_INVALID_NS_PDU: NS-PDU dump case ERROR CAUSE - OM_EVT_INVALID_NS_PDU: NS-PDU dump 7 = case ERROR CAUSE - OM_EVT_INVALID_NS_PDU: NS-PDU dump 8 = case ERROR CAUSE - OM_EVT_INVALID_NS_PDU: NS-PDU dump 9 = case ERROR CAUSE - OM_EVT_INVALID_NS_PDU: NS-PDU dump 10 = case ERROR CAUSE - OM_EVT_INVALID_NS_PDU: NS-PDU dump 11 = case ERROR CAUSE - OM_EVT_INVALID_NS_PDU: NS-PDU dump 12 = case ERROR CAUSE - OM_EVT_INVALID_NS_PDU: NS-PDU dump 13 = case ERROR CAUSE - OM_EVT_INVALID_NS_PDU: NS-PDU dump 14 = case ERROR CAUSE - OM_EVT_INVALID_NS_PDU: NS-PDU dump 15 = case ERROR CAUSE - OM_EVT_INVALID_NS_PDU: NS-PDU dump 16 = case ERROR CAUSE - OM_EVT_INVALID_NS_PDU: NS-PDU dump 17 = Not used 18 = Not used 19 = Not used 20 = Not used 21 = Not used 22 = Not used 23 = Not used 24 = Not used 25 = Not used 26 = Not used 27 = Not used 28 = Not used 29 = Not used 30 = Not used 31 = Not used 32 = Not used ##fine## 6=

A30808-X3247-K240-3-7619

811

Outputs OML:BSC

Base Station Controller

SYSINFO_ID: 078
SYSTEM INFO REPORT: Originator:

GBIC NS-PROTOCOL EVENT


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4953 TDHGPIHGB sysinfo description : This System Info Report maps a GbIC error event occurring in the following cases: NS Reset request from peer entity (OM_EVT_NS_RESET_REQUEST), NS Unblock request from peer entity for a blocked NSVC (OM_EVT_NS_UNBLOCK_REQUEST), NS Block request from peer entity for an unblocked NSVC (OM_EVT_NS_BLOCK_REQUEST), NS Unblock request refused by peer entity (OM_EVT_NS_UNBLOCK_REFUSED), NS-STATUS PDU received (OM_EVT_NS_STATUS) 1 = GbIC ERROR CAUSE: 0x50 = OM_EVT_NS_RESET_REQUEST 0x51 = OM_EVT_NS_UNBLOCK_REQUEST 0x52 = OM_EVT_NS_BLOCK_REQUEST 0x53 = OM_EVT_NS_UNBLOCK_REFUSED 0x54 = OM_EVT_NS_STATUS 2 = case ERROR CAUSE - OM_EVT_NS_RESET_REQUEST: cause field of NS-RESET PDU - OM_EVT_NS_BLOCK_REQUEST: cause field of NS-BLOCK PDU - OM_EVT_NS_UNBLOCK_REFUSED: cause field of NS-BLOCK PDU - OM_EVT_NS_STATUS: cause field in NS-STATUS PDU 3 = case ERROR CAUSE - OM_EVT_NS_STATUS: according to cause value of previous word and to GSM 08.16 specifications: NSVCI IE or BVCI IE or PDU type in PDU IE 4 = case ERROR CAUSE - OM_EVT_NS_STATUS: octet dump of PDU IE 5 = case ERROR CAUSE - OM_EVT_NS_STATUS: octet dump of PDU IE 6 = case ERROR CAUSE - OM_EVT_NS_STATUS: octet dump of PDU IE 7 = case ERROR CAUSE - OM_EVT_NS_STATUS: octet dump of PDU IE 8 = case ERROR CAUSE - OM_EVT_NS_STATUS: octet dump of PDU IE 9 = case ERROR CAUSE - OM_EVT_NS_STATUS: octet dump of PDU IE 10 = case ERROR CAUSE - OM_EVT_NS_STATUS: octet dump of PDU IE 11 = case ERROR CAUSE - OM_EVT_NS_STATUS: octet dump of PDU IE 12 = case ERROR CAUSE - OM_EVT_NS_STATUS: octet dump of PDU IE
812 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

13 =

case ERROR CAUSE - OM_EVT_NS_STATUS: octet dump of PDU IE 14 = case ERROR CAUSE - OM_EVT_NS_STATUS: octet dump of PDU IE 15 = case ERROR CAUSE - OM_EVT_NS_STATUS: octet dump of PDU IE 16 = case ERROR CAUSE - OM_EVT_NS_STATUS: octet dump of PDU IE 17 = Not used 18 = Not used 19 = Not used 20 = Not used 21 = Not used 22 = Not used 23 = Not used 24 = Not used 25 = Not used 26 = Not used 27 = Not used 28 = Not used 29 = Not used 30 = Not used 31 = Not used 32 = Not used ##fine##

A30808-X3247-K240-3-7619

813

Outputs OML:BSC

Base Station Controller

SYSINFO_ID: 079
SYSTEM INFO REPORT: Originator:

GBIC NS-CONGESTION STATUS CHANGE


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4953 TDHGPIHGB sysinfo description : This System Info Report maps a GbIC error event occurring on congestion situation modifications. 1 = GbIC ERROR CAUSE: 0x30 = OM_EVT_CONGESTION_START 0x31 = OM_EVT_CONGESTION_END8 2 = case ERROR CAUSE - OM_EVT_CONGESTION_START: congestion cause - OM_EVT_CONGESTION_END: not used 3 = Not used 4 = Not used 5 = Not used 6 = Not used 7 = Not used 8 = Not used 9 = Not used 10 = Not used 11 = Not used 12 = Not used 13 = Not used 14 = Not used 15 = Not used 16 = Not used 17 = Not used 18 = Not used 19 = Not used 20 = Not used 21 = Not used 22 = Not used 23 = Not used 24 = Not used 25 = Not used 26 = Not used 27 = Not used 28 = Not used 29 = Not used 30 = Not used 31 = Not used 32 = Not used
814 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

##fine##

A30808-X3247-K240-3-7619

815

Outputs OML:BSC

Base Station Controller

SYSINFO_ID: 080
SYSTEM INFO REPORT: Originator:

PCU ALIGNMENT FAILURE INFO


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4952 TDHGPDCMC sysinfo description : This System Info Report occurs when the PCUalignment is interrupted and the relative alarm is already pending. 1 = the line number of the source module 2 = PCU FSM state: 00 - GPFSM_OOS 01 - GPFSM_WAIT_CARD_ON 02 - GPFSM_INITIALIZING 03 - GPFSM_RELAX 04 - GPFSM_MONITOR 3 = Event causing the alignment interruption: 00 - GPEVT_NONE 01 - GPEVT_TMOUT 02 - GPEVT_CARDON 03 - GPEVT_CARDOFF 04 - GPEVT_PCUTMT 05 - GPEVT_PCUSENDERR 06 - GPEVT_PCUALGNREQ 07 - GPEVT_AUDITFAIL 08 - GPEVT_CMDFAIL 09 - GPEVT_CMDRESP 0a - GPEVT_CMDEND 0b - GPEVT_ALGNSTART 0c - GPEVT_SMUNLOCK 0d - GPEVT_SMLOCK 0e - GPEVT_SMDISABLE 0f - GPEVT_SMENABLE 4 = PCU Alignment state: 00 - GPASM_WAIT_START_ALGN 01 - GPASM_WAIT_PCU_ALGN 02 - GPASM_WAIT_PTP_ALGN 03 - GPASM_WAIT_GBICU_ALGN 04 - GPASM_WAIT_FRL_ALGN 05 - GPASM_WAIT_NSVC_ALGN 06 GPASM_WAIT_SCAN_ALGN 5 = Not used 6 = Not used 7 = Not used
816 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

8 = Not used 9 = Not used 10 = Not used 11 = Not used 12 = Not used 13 = Not used 14 = Not used 15 = Not used 16 = Not used 17 = Not used 18 = Not used 19 = Not used 20 = Not used 21 = Not used 22 = Not used 23 = Not used 24 = Not used 25 = Not used 26 = Not used 27 = Not used 28 = Not used 29 = Not used 30 = Not used 31 = Not used 32 = Not used ##fine##

A30808-X3247-K240-3-7619

817

Outputs OML:BSC

Base Station Controller

SYSINFO_ID: 081
SYSTEM INFO REPORT: Originator:

GBIC IPC PROBLEM


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4953 TDHGPIHGB sysinfo description : There is a warning message from GbIC. 1 = GbIC ERROR CAUSE: 0x60 = IC_GbIC_DEST_SYS_NOT_CORRECT 0x61 = IC_PARTITION_NO_NOT_CORRECT 0x62 = IC_MBX_ID_NOT_TRANSLATE 0x63 = IC_PSOS_Q_URGENT_ERROR 0x64 = IC_GbIC_WRONG_LEN 2 = SUBSYTEM INFORMATION (first two bytes) 3 = SUBSYTEM INFORMATION (last two bytes) 4 = SOFTWARE COMPONENT (first two bytes) 5 = SOFTWARE COMPONENT (last two bytes) 6 = TASK IDENTIFIER (first two bytes) 7 = TASK IDENTIFIER (last two bytes) 8 = MODULE IDENTIFIER (first two bytes) 9 = MODULE IDENTIFIER (last two bytes) 10 = PROCEDURE IDENTIFIER (first two bytes) 11 = PROCEDURE IDENTIFIER (last two bytes) 12 = REPORTING POINT IDENTIFIER (first two bytes) 13 = REPORTING POINT IDENTIFIER (last two bytes) 14 = pSOS ERROR CODE (first two bytes) 15 = pSOS ERROR CODE (last two bytes) 16 = MBLK ERROR CODE (first two bytes) 17 = MBLK ERROR CODE (last two bytes) 18 = RTN ERROR CODE (first two bytes) 19 = RTN ERROR CODE (last two bytes) 20 = Not used 21 = Not used 22 = Not used 23 = Not used 24 = Not used 25 = Not used 26 = Not used 27 = Not used 28 = Not used 29 = Not used 30 = Not used 31 = Not used
818 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

32 = Not used ##fine##

A30808-X3247-K240-3-7619

819

Outputs OML:BSC

Base Station Controller

SYSINFO_ID: 082
SYSTEM INFO REPORT: Originator:

PPCU FW DOWNLOAD IN PROGRESS


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4502 MDHXXDCEH sysinfo description : This system info is issued when on PPCU-MPCC DUAM a message of PPCU FW Load Start is read by PPCU DH (on MPCC) after a card reset; PPCU is Locked; this message means a Personal Computer is connected to PPCU through serial line and a PC tool is downloading a new version of FW on the PPCU. 1 = Source code line 2 = first byte of PCUC FW message on DUAM 3 = second byte of PCUC FW message 4 = third byte of PCUC FW message 5 = value of SW semafore inside MPCC -> PCUC interface 6 = first byte inside MPCC -> PCUC command (if any) on DUAM 7 = second byte inside MPCC -> PCUC command (if any) on DUAM 8 = third byte inside MPCC -> PCUC command (if any) on DUAM 9 = value of SW semafore inside PCUC -> MPCC interface 10 = first byte inside PCUC -> MPCC answer on DUAM 11 = second byte inside PCUC -> MPCC answer on DUAM 12 = third byte inside PCUC -> MPCC answer on DUAM 13 = copy of last written byte on UBEX register of PPCU (low byte) and alarms mask directly read on it (high byte) 14 = copy of active TDPC 15 = copy of Providing Service NTW 16 = last stored alarms relevant to current PPCU 17 = statuses bit mask (internal copy of DH) 18 = "reset retry" field of local PPCU database 19 = expiration time related to the card inside local db 20 = not used 21 = not used 22 = not used 23 = not used 24 = not used 25 = not used 26 = not used 27 = not used 28 = not used 29 = not used 30 = not used 31 = not used 32 = not used ##fine##
820 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

SYSINFO_ID: 083
SYSTEM INFO REPORT: Originator:

PPLD/PPCC FIRMWARE TEST FAILURE


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4502 MDHXXDCEH sysinfo description : This system info is issued when the PPLD or PPCC FW self-test (after micro reset) fails. Three cases are possible: a) no spontaneous FW answer comes to MPCC (on registers of card gate array) b) a negative FW answer is generated by FW c) a HW problem is detected during PPxx / MPCC interface. 1 = source code current line 2 = cases a, b: FW answer (> 0) or 0 (time-out); case c: error code (low byte), whose possible values are: 0xe4 = NMI during access to card 0x8f = HW semaphore locked 0xa0 = alarm detection while receiving FW answer - source code where HW problem was detected (high byte): 1 = DHXXDCCH.C 2 = DHXXDCDE 3 = DHXXDCEH 4 = DHXXDCSA 5 = DHXXDCSM 6 = DHXXDCTH 7 = DHXXDDDI 8 = DHXXDDHD 9 = DHXXGSUT 10 = DHXXINIT 11 = DHXXDGHD 12 = DHXXDDPU 3 = cases a,b: first byte of PPCU FW answer case c: line of source where failure was detected 4 = cases a,b: second byte of PPCU FW answer case c: first byte of PPCU FW answer 5 = cases a,b: third byte of PPCU FW answer case c: second byte of PPCU FW answer 6 = cases a,b: fourth byte of PPCU FW answer case c: third byte of PPCU FW answer 7 = cases a,b: sts field (local db inside PPCU DH): current PPCU state in DH finite state machine case c: fourth byte of PPCU FW answer 8 = cases a,b: status field (local db), consisting of a bit mask of statuses bits: DEPENDENCY 0x01 FAILED 0x02
A30808-X3247-K240-3-7619 821

Outputs OML:BSC

Base Station Controller

INITIALIZING 0x04 IN_TEST 0x08 NOT_INITIALIZED 0x10 OFFLINE 0x20 RESERVED FOR TEST 0x40 NOT INIT ALARMED 0x80 case c: sts field (local db inside PPCU DH): current PPCU state in DH finite state machine 9 = cases a,b: "reset retry" counter (PPCU DH local db) case c: status field (local db), consisting of a bit mask of statuses bits: DEPENDENCY 0x01 FAILED 0x02 INITIALIZING 0x04 IN_TEST 0x08 NOT_INITIALIZED 0x10 OFFLINE 0x20 RESERVED FOR TEST 0x40 NOT INIT ALARMED 0x80 10 = cases a,b: expiration timer (PPCU DH local db) case c: "reset retry" counter (PPCU DH local db) 11 = case c: expiration timer (PPCU DH local db) 12 = not used 13 = not used 14 = not used 15 = not used 16 = not used 17 = not used 18 = not used 19 = not used 20 = not used 21 = not used 22 = not used 23 = not used 24 = not used 25 = not used 26 = not used 27 = not used 28 = not used 29 = not used 30 = not used 31 = not used 32 = not used ##fine##

822

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

SYSINFO_ID: 084
SYSTEM INFO REPORT: Originator:

PPCU HW EXCEPTION
<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4969 UDHPDEXHN sysinfo description : This System Info report collects all the information related to an exception/NMI interrupt occurred on the PPCU board. 1 = Error Identifier: 1=Transient WDT, 2=not recoverable WDT , 3=QSPAN Error, 6=Hardware Access Error 2 = Action Required: internal code 3 = PIIX4 address = 0x61 - NMI Status and Control Register 4 = PIIX4 address = (Function 1) 0x6-07h - PCI Device Status Register 5 = ISA BUS address = 0x4020 - Confstatus 6 = Qspan Pci Control Status (High) 7 = Qspan Pci Control Status (Low) 8 = Qspan Pci-Qbus Error Control (High) 9 = Qspan Pci-Qbus Error Control (Low) 10 = Qspan Interrupt Status (High) 11 = Qspan Interrupt Status (Low)) 12 = ISA BUS address = 0xFF30 - DSP Reset Status 13 = PIC In Service 14 = Error Funtional Area Identifier: 0=UNKNOW, 1=PPCU, 2=MPC860, 3=ISA Bridge 4=Qspan Bridge, 5=DSP, 6=TDCP Duam, 7=MPCC Duam 15 = Exception Type: 0=Exception, 1=NMI 16 = Qspan address Error Log (Hight) 17 = Qspan address Error Log (Low) 18 = Qspan data Error Log (Hight) 19 = Qspan data Error Log (Low) 20 = Global Exception counter 21 = Functional Area Exception counter related to the current exception 22 = IP address (High) 23 = IP address (Low) 24 = Not used. 25 = Not used. 26 = Not used. 27 = Not used. 28 = Not used. 29 = Not used. 30 = Not used. 31 = Not used. 32 = Not used. ##fine##
A30808-X3247-K240-3-7619 823

Outputs OML:BSC

Base Station Controller

Case of XXXX = 4982 NDHPDEXHN, 4992 YDHPDEXHN sysinfo description : This System Info report collects all the information related to an exception/NMI interrupt occurred on the PPXU or PPXL board. 1 = Error Identifier: 1=Transient WDT, 2=not recoverable WDT , 6=Hardware Access Error 2 = Action Required: internal code 3 = PIIX4 address = 0x61 - NMI Status and Control Register 4 = PIIX4 address = (Function 1) 0x6-07h - PCI Device Status Register 5 = Meaningful for PPXU only: RegInt register, reporting who has sent an interrupt to MUNICH. Bits set to 1 show that the corresponding core sent the interrupt. 6 = Meaningful for PPXU only: Comreg Register: the host processor can control the DSP resets (A_RS, B_RS, C_RS, D_RS), the HPI port resets (RESET) and the selection of the HPI port of each subcore by writing the corresponding bits. 7 = Regclri register: used to clear the bits on the RegInt register. This register clears, bit a bit, the RegInt register. Clearing is active at 0. 8 = For PPXU only: MUNICH PCI command status 9 = For PPXU only: MUNICH add info 10 = MUSYCC PCI command status 11 = MUSYCC add info 12 = Fixed data (0xaa55) 13 = 82559 Ethernet interface in service 14 = ppxx functional part that asserting the caught exception (0 = unknown, 1 = PPXX, 5 = DSP (PPXU only), 7 = MPCC DUAM, 6 = TDPC DUAM, 2 = MUSYCC, 4 = MUNICH, and so on. 15 = 0x03 = NMI exception; 0x00 = interrupt exception 16 = meaningless 17 = meaningless 18 = meaningless 19 = meaningless 20 = Global counter of exceptions due to PPxx 21 = Counter of exceptions for the current source of exceptions. 22 = IP address (high) 23 = IP address (low) 24 = not used 25 = not used 26 = not used 27 = not used 28 = not used 29 = not used 30 = not used 31 = not used 32 = not used

824

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

SYSINFO_ID: 085
SYSTEM INFO REPORT: Originator:

PSOS SYSTEM CALL FAILURE


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 640 MRTEPSALL sysinfo description : This error is issued when a pSOS system call fails returning an error code. 1 = Used by designer to locate the module where the system info is issued. 2 = Used by designer to locate the module where the system info is issued. 3 = Used by designer to locate the module where the system info is issued. 4 = Used by designer to locate the module where the system info is issued. 5 = Line in the code where the system info is issued. 6 = Identifier of the failed pSOS system calls. It can assume one of the following values: 0x01 (T_CREATE_LBL) => t_create 0x02 (T_DELETE_LBL) => t_delete 0x03 (T_GETREG_LBL) => t_getreg 0x04 (T_IDENT_LBL) => t_ident 0x05 (T_MODE_LBL) => t_mode 0x06 (T_RESTART_LBL) => t_restart 0x07 (T_RESUME_LBL) => t_resume 0x08 (T_SETPRI_LBL) => t_setpri 0x09 (T_SETREG_LBL) => t_setreg 0x0A (T_START_LBL) => t_start 0x0B (T_SUSPEND_LBL) => t_suspend 0x11 (Q_BROADCAST_LBL) => q_broadcast 0x12 (Q_CREATE_LBL) => q_create 0x13 (Q_DELETE_LBL) => q_delete 0x14 (Q_IDENT_LBL) => q_ident 0x15 (Q_RECEIVE_LBL) => q_receive 0x16 (Q_SEND_LBL) => q_send 0x17 (Q_URGENT_LBL) => q_urgent 0x19 (DE_INIT_LBL) => de_init 0x1A (DE_CNTRL_LBL) => de_cntrl 0x1B (DE_WRITE_LBL) => de_write 0x1C (DE_READ_LBL) => de_read 7 = Error code returned by pSOS system call (rtn_Psos_Error). 8 = It is the second word of the variable contained in field 7. 9 = Current value of the variable runtsk->EntryPoint. 10 = It is the second word of the variable contained in field 9. 11 = Assumes a different meaning according to the value of field 6, as shown below: Field 6 => Field 11 0x01 => Task name (name) 0x02 => Task identifier (tid)
A30808-X3247-K240-3-7619 825

Outputs OML:BSC

Base Station Controller

12 = 13 =

14 = 15 =

0x03 => Task identifier (tid) 0x04 => Task name (name) 0x05 => Attributes to be changed (mask) 0x06 => Task identifier (tid) 0x07 => Task identifier (tid) 0x08 => Task identifier (tid) 0x09 => Task identifier (tid) 0x0A => Task identifier (tid) 0x0B => Task identifier (tid) 0x11 => Queue identifier (qid) 0x12 => Queue name (name) 0x13 => Queue identifier (qid) 0x14 => Queue name (name) 0x15 => Queue identifier (qid) 0x16 => Queue identifier (qid) 0x17 => Queue identifier (qid) 0x19 => Device Major number 0x1A => Device Major number 0x1B => Device Major number 0x1C => Device Major number It is the second word of the variable contained in field 11. Assumes a different meaning according to the value of field 6, as shown below: Field 6 => Field 13 0x01 => Task priority (prio) 0x02 => Not used 0x03 => Register number (regnum) 0x04 => Node number (node) 0x05 => New attributes (newmode) 0x06 => First startup argument (targs[0]) 0x07 => Not used 0x08 => New priority (newprio) 0x09 => Register number (regnum) 0x0A => Initial task attributes (mode) 0x0B => Not used 0x11 => First field in message buffer (msg_buf[0]) 0x12 => Queue size (count) 0x13 => Not used 0x14 => Node number (node) 0x15 => Queue attributes (flags) 0x16 => First field in message buffer (msg_buf[0]) 0x17 => First field in message buffer (msg_buf[0]). 0x19 => Device Minor number 0x1A => Device Minor number 0x1B => Device Minor number 0x1C => Device Minor number It is the second word of the variable contained in field 13. Assumes a different meaning according to the value of field 6, as shown below: Field 6 => Field 15 0x01 => Stack supervisor stack size (sstack) 0x02 => Not used 0x03 => Not used 0x04 => Not used 0x05 => Not used 0x06 => Second startup argument (targs[1]) 0x07 => Not used 0x08 => Not used 0x09 => Register value (regvalue)
A30808-X3247-K240-3-7619

826

Base Station Controller

Outputs OML:BSC

16 = 17 =

18 = 19 =

0x0A => Task address (start_address) 0x0B => Not used 0x11 => Second field in message buffer (msg_buf[1]) 0x12 => Queue attributes (flags) 0x13 => Not used 0x14 => Not used 0x15 => Timeout in clock ticks (timeout) 0x16 => Second field in message buffer (msg_buf[1]) 0x17 => Second field in message buffer (msg_buf[1]). 0x19 => Not used 0x1A => Not used 0x1B => Not used 0x1C => Not used It is the second word of the variable contained in field 15. Assumes a different meaning according to the value of field 6, as shown below: Field 6 => Field 17 0x01 => Task user stack size (ustack) 0x02 => Not used 0x03 => Not used 0x04 => Not used 0x05 => Not used 0x06 => Third startup argument (targs[2]) 0x07 => Not used 0x08 => Not used 0x09 => Not used 0x0A => First startup argument (targs[0]) 0x0B => Not used 0x11 => Third field in message buffer (msg_buf[2]) 0x12 => Not used 0x13 => Not used 0x14 => Not used 0x15 => Not used 0x16 => Third field in message buffer (msg_buf[2]) 0x17 => Third field in message buffer (msg_buf[2]) 0x19 => Not used 0x1A => Not used 0x1B => Not used 0x1C => Not used It is the second word of the variable contained in field 17. Assumes a different meaning according to the value of field 6, as shown below: Field 6 => Field 19 0x01 => Task attributes (flags) 0x02 => Not used 0x03 => Not used 0x04 => Not used 0x05 => Not used 0x06 => Fourth startup argument (targs[3]) 0x07 => Not used 0x08 => Not used 0x09 => Not used 0x0A => Second startup argument (targs[1]) 0x0B => Not used 0x11 => Fourth field in message buffer (msg_buf[3]) 0x12 => Not used 0x13 => Not used 0x14 => Not used 0x15 => Not used
827

A30808-X3247-K240-3-7619

Outputs OML:BSC

Base Station Controller

20 = 21 =

22 = 23 =

24 =
828

0x16 => Fourth field in message buffer (msg_buf[3]) 0x17 => Fourth field in message buffer (msg_buf[3]) 0x19 => Not used 0x1A => Not used 0x1B => Not used 0x1C => Not used It is the second word of the variable contained in field 19. Assumes a different meaning according to the value of field 6, as shown below: Field 6 => Field 21 0x01 => Not used 0x02 => Not used 0x03 => Not used 0x04 => Not used 0x05 => Not used 0x06 => Not used 0x07 => Not used 0x08 => Not used 0x09 => Not used 0x0A => Third startup argument (targs[2]) 0x0B => Not used 0x11 => Not used 0x12 => Not used 0x13 => Not used 0x14 => Not used 0x15 => Not used 0x16 => Not used 0x17 => Not used 0x19 => Not used 0x1A => Not used 0x1B => Not used 0x1C => Not used It is the second word of the variable contained in field 21. Assumes a different meaning according to the value of field 6, as shown below: Field 6 => Field 23 0x01 => Not used 0x02 => Not used 0x03 => Not used 0x04 => Not used 0x05 => Not used 0x06 => Not used 0x07 => Not used 0x08 => Not used 0x09 => Not used 0x0A => Fourth startup argument (targs[3]) 0x0B => Not used 0x11 => Not used 0x12 => Not used 0x13 => Not used 0x14 => Not used 0x15 => Not used 0x16 => Not used 0x17 => Not used 0x19 => Not used 0x1A => Not used 0x1B => Not used 0x1C => Not used It is the second word of the variable contained in field 23.
A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

25 =

pSOS identifier of the current task (PsosId). The value 0x0000 makes the field invalid and meaningless. 26 = It is the second word of the variable contained in field 25. 27 = pSOS name of the current task (name). The value 0x0000 makes the field invalid and meaningless. 28 = It is the second word of the variable contained in field 27. 29 = pSOS name of the current queue (qid). The value 0x0000 makes the field invalid and meaningless. This field is meaningful only if field 6 assumes the value 0x11, 0x12, 0x13, 0x15, 0x16 or 0x17. 30 = It is the second word of the variable contained in field 29. 31 = pSOS entry point of the current task (PsosEntryPoint). The value 0x0000 makes the field invalid and meaningless. 32 = It is the second word of the variable contained in field 31. ##fine##

A30808-X3247-K240-3-7619

829

Outputs OML:BSC

Base Station Controller

SYSINFO_ID: 086
SYSTEM INFO REPORT: Originator:

TASKIFTABLE UPDATE FAILURE


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 640 MRTEPSALL sysinfo description : This error is issued during the updating of the TaskIfTable. This table contains elements that can belong to three different lists: the list of free elements, the list of tasks that must change their priority (PriorityList) and the list of tasks that are suspended (SuspendList). A function call has been made in order to manage the TaskIfTable but the function has returned a bad value (error code). 1 = Used by designer to locate the module where the system info is issued. 2 = Used by designer to locate the module where the system info is issued. 3 = Used by designer to locate the module where the system info is issued. 4 = Used by designer to locate the module where the system info is issued. 5 = Line in the code where the system info is issued. 6 = Error type. It is used to identify the high level procedure that contains the call to the function that has really originated the error. It can assume one of the following values: 0x01 => Error in the function AddToPriorityList 0x02 => Error in the function AddToSuspendList 0x03 => Error in the function DeleteElemTIT 0x05 => Error in the function FreeIndexTIT (no free elements are available in the TaskIfTable). 0x06 => Error in the function UpdateTIT 0x08 => Error in the function DelSuspendList 0x09 => Bad value for the index into TakIfTable 7 = Error code returned by the called function, specified by field 6. This is the same error code returned by the function that has really originated the error. It can assume one of the following values: 0x01 => Error in the function AddToPriorityList 0x05 => Error in the function FreeIndexTIT (no free elements are available in the TaskIfTable) 0x07 => Error in the function DelPriorityList 0x08 => Error in the function DelSuspendList 0x09 => Bad value for the index into TakIfTable 0x0A => Bad value returned from t_getreg, called in a function related to TIT management 8 = It is the second word of the variable contained in field 7. 9 = RTE+ entry point of the task to be added (or deleted) from a list managed in the TaskIfTable (PsosId). This field is meaningful only if field 6 assumes the value 0x01, 0x02, 0x03 or 0x06 or 0x09. 10 = It is the second word of the variable contained in field 9. 11 = Head of the list of suspended tasks (SuspendList.Head). 12 = It is the second word of the variable contained in field 11. 13 = Tail of the list of suspended tasks (SuspendList.Tail). 14 = It is the second word of the variable contained in field 13. 15 = Head of the list of suspended tasks (PriorityList.Head). 16 = It is the second word of the variable contained in field 15.
830 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

17 = Tail of the list of suspended tasks (PriorityList.Tail). 18 = It is the second word of the variable contained in field 17. 19 = Index of the first free element in the TaskIfTable (FirstFreeTIT). 20 = It is the second word of the variable contained in field 19. 21 = Not used. 22 = Not used. 23 = Not used. 24 = Not used. 25 = Not used. 26 = Not used. 27 = Not used. 28 = Not used. 29 = Not used. 30 = Not used. 31 = Not used. 32 = Not used. ##fine##

A30808-X3247-K240-3-7619

831

Outputs OML:BSC

Base Station Controller

SYSINFO_ID: 087
SYSTEM INFO REPORT: Originator:

INVALID PRIORITY
<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 640 MRTEPSALL sysinfo description : The error is issued when a check is made on the priority of a task: the result is that the pSOS or RTE+ priority is not valid. 1 = Used by designer to locate the module where the system info is issued. 2 = Used by designer to locate the module where the system info is issued. 3 = Used by designer to locate the module where the system info is issued. 4 = Used by designer to locate the module where the system info is issued. 5 = Line in the code where the system info is issued. 6 = Identifier of the priority type. It can assume one of the following values: 0x00 RTE+ priority is invalid 0x01 pSOS priority is invalid 0x02 value of the flag FlagPriority is invalid 7 = Invalid priority value. 8 = It is the second word of the variable contained in field 7. 9 = Current value of the variable runtsk. 10 = It is the second word of the variable contained in field 9. 11 = Current value of the variable runtsk ->EntryPoint. 12 = It is the second word of the variable contained in field 11. 13 = pSOS identifier of the current task (PsosId). The value 0x0000 makes the field invalid and meaningless. 14 = It is the second word of the variable contained in field 13. 15 = pSOS name of the current task (name). The value 0x0000 makes the field invalid and meaningless. 16 = It is the second word of the variable contained in field 15. 17 = pSOS entry point of the current task (PsosEntryPoint). The value 0x0000 makes the field invalid and meaningless. 18 = It is the second word of the variable contained in field 17. 19 = Not used. 20 = Not used. 21 = Not used. 22 = Not used. 23 = Not used. 24 = Not used. 25 = Not used. 26 = Not used. 27 = Not used. 28 = Not used. 29 = Not used. 30 = Not used.
832 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

31 = Not used. 32 = Not used. ##fine##

A30808-X3247-K240-3-7619

833

Outputs OML:BSC

Base Station Controller

SYSINFO_ID: 088
SYSTEM INFO REPORT: Originator:

INVALID STATUS
<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 640 MRTEPSALL sysinfo description : The error is issued when a check is made on the status of a task: the result is that the RTE+ status is not valid. 1 = Used by designer to locate the module where the system info is issued. 2 = Used by designer to locate the module where the system info is issued. 3 = Used by designer to locate the module where the system info is issued. 4 = Used by designer to locate the module where the system info is issued. 5 = Line in the code where the system info is issued. 6 = Not used. 7 = RTE+ invalid status value. 8 = It is the second word of the variable contained in field 7. 9 = Current value of the variable runtsk. 10 = It is the second word of the variable contained in field 9. 11 = Current value of the variable runtsk->EntryPoint. 12 = It is the second word of the variable contained in field 11. 13 = pSOS identifier of the current task (PsosId). The value 0x0000 makes the field invalid and meaningless. 14 = It is the second word of the variable contained in field 13. 15 = pSOS name of the current task (name). The value 0x0000 makes the field invalid and meaningless. 16 = It is the second word of the variable contained in field 15. 17 = pSOS entry point of the current task (PsosEntryPoint). The value 0x0000 makes the field invalid and meaningless. 18 = It is the second word of the variable contained in field 17. 19 = Not used. 20 = Not used. 21 = Not used. 22 = Not used. 23 = Not used. 24 = Not used. 25 = Not used. 26 = Not used. 27 = Not used. 28 = Not used. 29 = Not used. 30 = Not used. 31 = Not used. 32 = Not used. ##fine##
834 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

A30808-X3247-K240-3-7619

835

Outputs OML:BSC

Base Station Controller

SYSINFO_ID: 089
SYSTEM INFO REPORT: Originator:

PSOS MESSAGE INVALID FIELD


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 640 MRTEPSALL sysinfo description : The error is issued when a check is made on one of the fields of a pSOS message buffer: the result is that the value contained in the field is not valid. A pSOS message buffer is a structure made of four fields and each field is 32-bit long. 1 = Used by designer to locate the module where the system info is issued. 2 = Used by designer to locate the module where the system info is issued. 3 = Used by designer to locate the module where the system info is issued. 4 = Used by designer to locate the module where the system info is issued. 5 = Line in the code where the system info is issued. 6 = Not Used. 7 = pSOS identifier of the queue on which the message was received (qid). The value 0x0000 makes the field invalid and meaningless. 8 = It is the second word of the variable contained in field 7. 9 = pSOS name of the queue on which the message was received (name). The value 0x0000 makes the field invalid and meaningless. 10 = It is the second word of the variable contained in field 9. 11 = Index of the invalid field. It can assume a value between 0x00 and 0x03. 12 = Not Used. 13 = Content of the first field in the message buffer (msg_buf[0]). 14 = It is the second word of the variable contained in field 13. 15 = Content of the second field in the message buffer (msg_buf[1]). 16 = It is the second word of the variable contained in field 15. 17 = Content of the third field in the message buffer (msg_buf[2]). 18 = It is the second word of the variable contained in field 17. 19 = Content of the fourth field in the message buffer (msg_buf[3]). 20 = It is the second word of the variable contained in field 19. 21 = pSOS identifier of the task that received the message (PsosId). The value 0x0000 makes the field invalid and meaningless. 22 = It is the second word of the variable contained in field 21. 23 = pSOS name of the task that received the message (name). The value 0x0000 makes the field invalid and meaningless. 24 = It is the second word of the variable contained in field 23. 25 = pSOS entry point of the task that received the message (PsosEntryPoint). The value 0x0000 makes the field invalid and meaningless. 26 = It is the second word of the variable contained in field 25. 27 = Not used. 28 = Not used. 29 = Not used.
836 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

30 = Not used. 31 = Not used. 32 = Not used. ##fine##

A30808-X3247-K240-3-7619

837

Outputs OML:BSC

Base Station Controller

SYSINFO_ID: 090
SYSTEM INFO REPORT: Originator:

PSOS START MODE FAILURE


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 640 MRTEPSALL sysinfo description : Every pSOS task must receive as input parameter the start mode: it identifies the action that must be performed (start, restart, abort, etc.). The error is issued when this parameter is not valid. 1 = Used by designer to locate the module where the system info is issued. 2 = Used by designer to locate the module where the system info is issued. 3 = Used by designer to locate the module where the system info is issued. 4 = Used by designer to locate the module where the system info is issued. 5 = Line in the code where the system info is issued. 6 = Invalid start mode value (value of the variable start_mode). 7 = pSOS identifier of the task that should perform the action identified by the start mode parameter (PsosId). The value 0x0000 makes the field invalid and meaningless. 8 = It is the second word of the variable contained in field 7. 9 = pSOS name of the task that should perform the action identified by the start mode parameter (name). The value "RTET" identifies a generic RTE+ application task; the value 0x0000 makes the field invalid and meaningless. 10 = It is the second word of the variable contained in field 9. 11 = pSOS entry point of the task that should perform the action identified by the start mode parameter (PsosEntryPoint). The value 0x0000 makes the field invalid and meaningless. 12 = It is the second word of the variable contained in field 11. 13 = Not used. 14 = Not used. 15 = Not used. 16 = Not used. 17 = Not used. 18 = Not used. 19 = Not used. 20 = Not used. 21 = Not used. 22 = Not used. 23 = Not used. 24 = Not used. 25 = Not used. 26 = Not used. 27 = Not used. 28 = Not used. 29 = Not used. 30 = Not used. 31 = Not used.
838 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

32 = Not used. ##fine##

A30808-X3247-K240-3-7619

839

Outputs OML:BSC

Base Station Controller

SYSINFO_ID: 091
SYSTEM INFO REPORT: Originator:

RTE+PS INVALID SCHEDULING PHASE


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 640 MRTEPSALL sysinfo description : In RTE+PS the kernel identifies different scheduling phases using a global variable (PhaseSched). The error is issued when a check is made on this variable and the resulting value is not valid. 1 = Used by designer to locate the module where the system info is issued. 2 = Used by designer to locate the module where the system info is issued. 3 = Used by designer to locate the module where the system info is issued. 4 = Used by designer to locate the module where the system info is issued. 5 = Line in the code where the system info is issued. 6 = Not Used. 7 = Invalid scheduling phase (value of the variable PhaseSched). 8 = It is the second word of the variable contained in field 7. 9 = Current value of the variable runtsk. 10 = It is the second word of the variable contained in field 9. 11 = Current value of the variable runtsk->EntryPoint. 12 = It is the second word of the variable contained in field 11. 13 = pSOS identifier of the current task (PsosId). The value 0x0000 makes the field invalid and meaningless. 14 = It is the second word of the variable contained in field 13. 15 = pSOS name of the current task (name). The value 0x0000 makes the field invalid and meaningless. 16 = It is the second word of the variable contained in field 15. 17 = pSOS entry point of the current task (PsosEntryPoint). The value 0x0000 makes the field invalid and meaningless. 18 = It is the second word of the variable contained in field 17. 19 = Not used. 20 = Not used. 21 = Not used. 22 = Not used. 23 = Not used. 24 = Not used. 25 = Not used. 26 = Not used. 27 = Not used. 28 = Not used. 29 = Not used. 30 = Not used. 31 = Not used. 32 = Not used. ##fine##
840 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

SYSINFO_ID: 092
SYSTEM INFO REPORT: Originator:

PSOSTASKTABLE UPDATE FAILURE


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 640 MRTEPSALL sysinfo description : This error is issued during the updating or management of the PsosTaskTable. This table contains elements that can belong to two different lists: the list of free elements and the list of elements currently associated to a task (UsedListPTT). An element of the PsosTaskTable is associated to a task when the task is started, this association ceases to be when the task is deleted. 1 = Used by designer to locate the module where the system info is issued. 2 = Used by designer to locate the module where the system info is issued. 3 = Used by designer to locate the module where the system info is issued. 4 = Used by designer to locate the module where the system info is issued. 5 = Line in the code where the system info is issued. 6 = Error type. It is used to identify the high level procedure that contains the call to the function that has really originated the error. It can assume one of the following values: 0x12 => Error in the function DeleteElemPTT. 0x13 => Error in the function FreeIndexPTT (no free elements are available). 0x14 => Error in the function UpdatePTT. 0x16 => Bad value for the index into the PsosTaskTable. 7 = Error code returned by the called function, specified by field 6. This is the same error code returned by the function that has really originated the error. It can assume one of the following values: 0x11 => Error in the function AddToUsedList. 0x13 => Error in the function FreeIndexPTT (no free elements are available). 0x15 => Error in the function DeleUsedList. 0x16 => Bad value for the index into the PsosTaskTable. 8 = It is the second word of the variable contained in field 7. 9 = When field 6 assumes the value 0x16 this field is the pSOS identifier of the task to be inserted into (or deleted from) the PsosTaskTable (PsosId) otherwise is the pSOS entry point of the task. 10 = It is the second word of the variable contained in field 9. 11 = Index of the current element in PsosTaskTable. This field is meaningful only if field 6 assumes the value 0x12, 0x14 or 0x16. 12 = It is the second word of the variable contained in field 11. 13 = Head of the list of elements in the PsosTaskTable associated to a started task (UsedListPTT.Head). 14 = It is the second word of the variable contained in field 13. 15 = Tail of the list of elements in the PsosTaskTable associated to a started task (UsedListPTT.Tail). 16 = It is the second word of the variable contained in field 15. 17 = Index of the first free element in the PsosTaskTable (FirstFreePTT). 18 = It is the second word of the variable contained in field 17. 19 = Not used. 20 = Not used. 21 = Not used.
A30808-X3247-K240-3-7619 841

Outputs OML:BSC

Base Station Controller

22 = Not used. 23 = Not used. 24 = Not used. 25 = Not used. 26 = Not used. 27 = Not used. 28 = Not used. 29 = Not used. 30 = Not used. 31 = Not used. 32 = Not used. ##fine##

842

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

SYSINFO_ID: 093
SYSTEM INFO REPORT: Originator:

MPCC DB LOAD START


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 2002 MDBCATDTD sysinfo description : Start the restore of MPCC Data Base 1 = Not used 2 = Not used 3 = Not used 4 = Not used 5 = Not used 6 = Not used 7 = Not used 8 = Not used 9 = Not used 10 = Not used 11 = Not used 12 = Not used 13 = Not used 14 = Not used 15 = Not used 16 = Not used 17 = Not used 18 = Not used 19 = Not used 20 = Not used 21 = Not used 22 = Not used 23 = Not used 24 = Not used 25 = Not used 26 = Not used 27 = Not used 28 = Not used 29 = Not used 30 = Not used 31 = Not used 32 = Not used ##fine##

A30808-X3247-K240-3-7619

843

Outputs OML:BSC

Base Station Controller

SYSINFO_ID: 094
SYSTEM INFO REPORT: Originator:

TDPC DB ALIGNMENT START


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 2002 MDBCATDTD sysinfo description : Start the transmission to TDPC of MPCC Data Base 1 = Not used 2 = Not used 3 = Not used 4 = Not used 5 = Not used 6 = Not used 7 = Not used 8 = Not used 9 = Not used 10 = Not used 11 = Not used 12 = Not used 13 = Not used 14 = Not used 15 = Not used 16 = Not used 17 = Not used 18 = Not used 19 = Not used 20 = Not used 21 = Not used 22 = Not used 23 = Not used 24 = Not used 25 = Not used 26 = Not used 27 = Not used 28 = Not used 29 = Not used 30 = Not used 31 = Not used 32 = Not used ##fine##

844

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

SYSINFO_ID: 095
SYSTEM INFO REPORT: Originator:

MPCC DB LOAD END


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 2002 MDBCATDTD sysinfo description : End of restore of MPCC Data Base 1 = Not used 2 = Not used 3 = Not used 4 = Not used 5 = Not used 6 = Not used 7 = Not used 8 = Not used 9 = Not used 10 = Not used 11 = Not used 12 = Not used 13 = Not used 14 = Not used 15 = Not used 16 = Not used 17 = Not used 18 = Not used 19 = Not used 20 = Not used 21 = Not used 22 = Not used 23 = Not used 24 = Not used 25 = Not used 26 = Not used 27 = Not used 28 = Not used 29 = Not used 30 = Not used 31 = Not used 32 = Not used ##fine##

A30808-X3247-K240-3-7619

845

Outputs OML:BSC

Base Station Controller

SYSINFO_ID: 096
SYSTEM INFO REPORT: Originator:

TDPC DB ALIGNMENT END


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 2002 MDBCATDTD sysinfo description : End of restore of TDPC Data Base 1 = Not used 2 = Not used 3 = Not used 4 = Not used 5 = Not used 6 = Not used 7 = Not used 8 = Not used 9 = Not used 10 = Not used 11 = Not used 12 = Not used 13 = Not used 14 = Not used 15 = Not used 16 = Not used 17 = Not used 18 = Not used 19 = Not used 20 = Not used 21 = Not used 22 = Not used 23 = Not used 24 = Not used 25 = Not used 26 = Not used 27 = Not used 28 = Not used 29 = Not used 30 = Not used 31 = Not used 32 = Not used ##fine##

846

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

SYSINFO_ID: 097
SYSTEM INFO REPORT: Originator:

MPCC DB LOAD FAILURE


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 2002 MDBCATDTD sysinfo description : The system info is issued when the restore of MPCC Data Base fails. These cases are possibles:\ a) Abort of DB load controller task b) DB Loader Task doesn't answer to DB Load Controller before the processor timer PROC_TIMER_MPCC has expired c) DB Loader Task send a negative answer to DB load controller 1 = Not used 2 = Not used 3 = Not used 4 = Not used 5 = Not used 6 = Not used 7 = Not used 8 = Not used 9 = Not used 10 = Not used 11 = Not used 12 = Not used 13 = Not used 14 = Not used 15 = Not used 16 = Not used 17 = Not used 18 = Not used 19 = Not used 20 = Not used 21 = Not used 22 = Not used 23 = Not used 24 = Not used 25 = Not used 26 = Not used 27 = Not used 28 = Not used 29 = 30 = 31 =
A30808-X3247-K240-3-7619 847

Outputs OML:BSC

Base Station Controller

32 = ##fine##

848

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

SYSINFO_ID: 098
SYSTEM INFO REPORT: Originator:

TDPC DB ALIGNMENT FAILURE


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 2002 MDBCATDTD sysinfo description : The system info is issued when the transmission of MPCC Data Base to TDPC fails. These cases are possibles: a) Abort of DB load controller task b) DB Loader Task doesn' t answer to DB Load Controller before the processor timer PROC_TIMER_TDPC has expired c) DB Loader Task send a negative answer to DB load controller 1 = Not used 2 = Not used 3 = Not used 4 = Not used 5 = Not used 6 = Not used 7 = Not used 8 = Not used 9 = Not used 10 = Not used 11 = Not used 12 = Not used 13 = Not used 14 = Not used 15 = Not used 16 = Not used 17 = Not used 18 = Not used 19 = Not used 20 = Not used 21 = Not used 22 = Not used 23 = Not used 24 = Not used 25 = Not used 26 = Not used 27 = Not used 28 = Not used 29 = 30 = 31 =
A30808-X3247-K240-3-7619 849

Outputs OML:BSC

Base Station Controller

32 = ##fine##

850

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

SYSINFO_ID: 099
SYSTEM INFO REPORT: Originator:

DB BACKUP START
<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 2003 MDBCASRBK sysinfo description : Start the DB backup copy onto DK40 disk 1 = Not used 2 = Not used 3 = Not used 4 = Not used 5 = Not used 6 = Not used 7 = Not used 8 = Not used 9 = Not used 10 = Not used 11 = Not used 12 = Not used 13 = Not used 14 = Not used 15 = Not used 16 = Not used 17 = Not used 18 = Not used 19 = Not used 20 = Not used 21 = Not used 22 = Not used 23 = Not used 24 = Not used 25 = Not used 26 = Not used 27 = Not used 28 = Not used 29 = Not used 30 = Not used 31 = Not used 32 = Not used ##fine##

A30808-X3247-K240-3-7619

851

Outputs OML:BSC

Base Station Controller

SYSINFO_ID: 100
SYSTEM INFO REPORT: Originator:

DB BACKUP END
<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 2003 MDBCASRBK sysinfo description : End of Data Base backup onto DK40 disk 1 = Not used 2 = Not used 3 = Not used 4 = Not used 5 = Not used 6 = Not used 7 = Not used 8 = Not used 9 = Not used 10 = Not used 11 = Not used 12 = Not used 13 = Not used 14 = Not used 15 = Not used 16 = Not used 17 = Not used 18 = Not used 19 = Not used 20 = Not used 21 = Not used 22 = Not used 23 = Not used 24 = Not used 25 = Not used 26 = Not used 27 = Not used 28 = Not used 29 = Not used 30 = Not used 31 = Not used 32 = Not used ##fine##

852

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

SYSINFO_ID: 101
SYSTEM INFO REPORT: Originator:

DB BACKUP FAILURE
<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 2003 MDBCASRBK sysinfo description : Data base backup onto DK40 disk failed 1 = Not used 2 = Not used 3 = Not used 4 = Not used 5 = Not used 6 = Not used 7 = Not used 8 = Not used 9 = Not used 10 = Not used 11 = Not used 12 = Not used 13 = Not used 14 = Not used 15 = Not used 16 = Not used 17 = Not used 18 = Not used 19 = Not used 20 = Not used 21 = Not used 22 = Not used 23 = Not used 24 = Not used 25 = Not used 26 = Not used 27 = Not used 28 = Not used 29 = Not used 30 = Not used 31 = Not used 32 = Not used ##fine##

A30808-X3247-K240-3-7619

853

Outputs OML:BSC

Base Station Controller

SYSINFO_ID: 102
SYSTEM INFO REPORT: Originator:

DELETE RTE TASK FAILURE


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 640 MRTEPSALL sysinfo description : The error is issued when an exception occurs in a native pSOS task and the action to perform in response to this event is different from initialization (start, restart or abort of the task). 1 = Used by designer to locate the module where the system info is issued. 2 = Used by designer to locate the module where the system info is issued. 3 = Used by designer to locate the module where the system info is issued. 4 = Used by designer to locate the module where the system info is issued. 5 = Line in the code where the system info is issued. 6 = Not Used. 7 = Current value of the variable runtsk. 8 = It is the second word of the variable contained in field 7. 9 = Entry point of the task that should be deleted. 10 = It is the second word of the variable contained in field 9. 11 = RTE priority of the task that should be deleted. 12 = It is the second word of the variable contained in field 11. 13 = RTE TCB task pointer. 14 = It is the second word of the variable contained in field 13. 15 = Not used. 16 = Not used. 17 = Not used. 18 = Not used. 19 = Not used. 20 = Not used. 21 = Not used. 22 = Not used. 23 = Not used. 24 = Not used. 25 = Not used. 26 = Not used. 27 = Not used. 28 = Not used. 29 = Not used. 30 = Not used. 31 = Not used. 32 = Not used. ##fine##

854

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

SYSINFO_ID: 103
SYSTEM INFO REPORT: Originator:

LPDL LINK UNSTABLE


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4802 TDHLPDCEN sysinfo description : When this system information is output the behavior of the referenced link is declared as "unstable" because too many "link-up"-"link_down" events in sequence has been detected from the LAPD Device Handler. 1 = lapd finite state machine (developer oriented). 2 = lapd instability counter (developer oriented). 3 = lapd instability period (developer oriented). 4 = lapd sysinfo alarm flag (developer oriented). 5 = lapd sysinfo timer (developer oriented). 6 = Not used. 7 = Not used. 8 = Not used. 9 = Not used. 10 = Not used. 11 = Not used. 12 = Not used. 13 = Not used. 14 = Not used. 15 = Not used. 16 = Not used. 17 = Not used. 18 = Not used. 19 = Not used. 20 = Not used. 21 = Not used. 22 = Not used. 23 = Not used. 24 = Not used. 25 = Not used. 26 = Not used. 27 = Not used. 28 = Not used. 29 = Not used. 30 = Not used. 31 = Not used. 32 = Not used. ##fine##

A30808-X3247-K240-3-7619

855

Outputs OML:BSC

Base Station Controller

SYSINFO_ID: 104
SYSTEM INFO REPORT: Originator:

BTSM FAST ALIGNMENT INFO


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4704 TDHBFDCMC sysinfo description : It's used to notity that a BTSM fast alignment has been triggered. 1 = Internal code of the event that triggered this fast alignment: BMEVT_NONE = 0x00, BMEVT_TMOUT = 0x01, BMEVT_SWALGOK = 0x02, BMEVT_SWALGEND = 0x03, BMEVT_SWSTRDWLD = 0x04, BMEVT_SWALGFAIL = 0x05, BMEVT_SWREFRESH = 0x06, BMEVT_LINKUP = 0x07, BMEVT_LINKDOWN = 0x08, BMEVT_ABISTMT = 0x09, BMEVT_ABISENDERR = 0x0a, BMEVT_SYSALGNREQ = 0x0b, BMEVT_AUDITFAIL = 0x0c, BMEVT_MSGDSBL = 0x0d, BMEVT_MSGENBL = 0x0e, BMEVT_STOPEVREP = 0x0f, BMEVT_RSTEVREP = 0x10, BMEVT_RESETRES = 0x11, BMEVT_RCVNACK = 0x12, BMEVT_SMENBL = 0x13, BMEVT_SMDSBL = 0x14, BMEVT_SMUNLOCK = 0x15, BMEVT_DBDHKLV = 0x16, BMEVT_DBDHERR = 0x17, BMEVT_DBDHREQ = 0x18, BMEVT_DBDHRPL = 0x19, BMEVT_ADMOK = 0x1a, BMEVT_BFSTRTM = 0x1b, BMEVT_ABISDEL = 0x1c BMEVT_SALESOK, = 0x1d BMEVT_SALESFAIL = 0x1e BMEVT_SMLOCK = 0x1f BMEVT_LOCKOK = 0x20 2 = Internal code of the current state of state machine: BMFSM_LINK_DOWN = 0x00,
856 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

BMFSM_WAIT_STOP_EVT = 0x01, BMFSM_WAIT_SW_ALIGN = 0x02, BMFSM_WAIT_DB_ALIGN = 0x03, BMFSM_WAIT_RESET_RES = 0x04, BMFSM_WAIT_REST_EVT = 0x05, BMFSM_WAIT_EVT_REP = 0x06, BMFSM_MONITOR = 0x07, BMFSM_WAIT_DBDH = 0x08, BMFSM_WAIT_RELAX_TIME= 0x09 BMFSM_WAIT_SALES_EVT = 0x0a BMFSM_WAIT_LOCK = 0x0b 3 = Internal code of the new state of state machine: BMFSM_WAIT_REST_EVT = 0x05 4 = counter of the Fast alignment event occurred. 5 = Not used. 6 = Not used. 7 = Not used. 8 = Not used. 9 = Not used. 10 = Not used. 11 = Not used. 12 = Not used. 13 = Not used. 14 = Not used. 15 = Not used. 16 = Not used. 17 = Not used. 18 = Not used. 19 = Not used. 20 = Not used. 21 = Not used. 22 = Not used. 23 = Not used. 24 = Not used. 25 = Not used. 26 = Not used. 27 = Not used. 28 = Not used. 29 = Not used. 30 = Not used. 31 = Not used. 32 = Not used. ##fine##

A30808-X3247-K240-3-7619

857

Outputs OML:BSC

Base Station Controller

SYSINFO_ID: 105
SYSTEM INFO REPORT: Originator:

NETWORK System Info


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4205 MDHNWDCAL sysinfo description : Transient alarm on Network 1 = Source code line 2 = Error type 3 = Device type 4 = High level originator 5 = High level code line 6 = Ubex alarm register 7 = PLLH alarm registers 8 = SN Control and Inpiu Block alarm registers 9 = SN Output and sense registers 10 = SN Alarmed 8Mb/s lines n. 16..24 11 = SN Alarmed 8Mb/s lines n. 0..15 12 = SN Alarmed 2Mb/s lines towards PPXX 13 = SN Comparison alarmed lines n. 16..24 14 = SN Comparison alarmed lines n. 0..15 15 = Other alarms 16 = Not used 17 = Not used 18 = Not used 19 = Not used 20 = Not used 21 = Not used 22 = Not used 23 = Not used 24 = Not used 25 = Not used 26 = Not used 27 = Not used 28 = Not used 29 = Not used 30 = Not used 31 = Not used 32 = Not used ##fine##

858

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

SYSINFO_ID: 106
SYSTEM INFO REPORT: Originator:

PLLH System Info


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4205 MDHNWDCAL sysinfo description : Transient alarm on PLLH 1 = Source code line 2 = Error type 3 = Device type 4 = High level originator 5 = High level code line 6 = Ubex alarm register 7 = PLLH alarm registers 8 = SN Control and Inpiu Block alarm registers 9 = SN Output and sense registers 10 = SN Alarmed 8Mb/s lines n. 16..24 11 = SN Alarmed 8Mb/s lines n. 0..15 12 = SN Alarmed 2Mb/s lines towards PPXX 13 = SN Comparison alarmed lines n. 16..24 14 = SN Comparison alarmed lines n. 0..15 15 = Other alarms 16 = Not used 17 = Not used 18 = Not used 19 = Not used 20 = Not used 21 = Not used 22 = Not used 23 = Not used 24 = Not used 25 = Not used 26 = Not used 27 = Not used 28 = Not used 29 = Not used 30 = Not used 31 = Not used 32 = Not used ##fine##

A30808-X3247-K240-3-7619

859

Outputs OML:BSC

Base Station Controller

SYSINFO_ID: 107
SYSTEM INFO REPORT: Originator:

UBEX System Info


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4205 MDHNWDCAL sysinfo description : Transient alarm on UBEX 1 = Source code line 2 = Error type 3 = Device type 4 = High level originator 5 = High level code line 6 = Ubex alarm register 7 = PLLH alarm registers 8 = SN Control and Inpiu Block alarm registers 9 = SN Output and sense registers 10 = SN Alarmed 8Mb/s lines n. 16..24 11 = SN Alarmed 8Mb/s lines n. 0..15 12 = SN Alarmed 2Mb/s lines towards PPXX 13 = SN Comparison alarmed lines n. 16..24 14 = SN Comparison alarmed lines n. 0..15 15 = Other alarms 16 = Not used 17 = Not used 18 = Not used 19 = Not used 20 = Not used 21 = Not used 22 = Not used 23 = Not used 24 = Not used 25 = Not used 26 = Not used 27 = Not used 28 = Not used 29 = Not used 30 = Not used 31 = Not used 32 = Not used ##fine##

860

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

SYSINFO_ID: 108
SYSTEM INFO REPORT: Originator:

SN64 System Info


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4205 MDHNWDCAL sysinfo description : Transient alarm on SN64 1 = Source code line 2 = Error type 3 = Device type 4 = High level originator 5 = High level code line 6 = Ubex alarm register 7 = PLLH alarm registers 8 = SN Control and Inpiu Block alarm registers 9 = SN Output and sense registers 10 = SN Alarmed 8Mb/s lines n. 16..24 11 = SN Alarmed 8Mb/s lines n. 0..15 12 = SN Alarmed 2Mb/s lines towards PPXX 13 = SN Comparison alarmed lines n. 16..24 14 = SN Comparison alarmed lines n. 0..15 15 = Other alarms 16 = Not used 17 = Not used 18 = Not used 19 = Not used 20 = Not used 21 = Not used 22 = Not used 23 = Not used 24 = Not used 25 = Not used 26 = Not used 27 = Not used 28 = Not used 29 = Not used 30 = Not used 31 = Not used 32 = Not used ##fine##

A30808-X3247-K240-3-7619

861

Outputs OML:BSC

Base Station Controller

SYSINFO_ID: 109
SYSTEM INFO REPORT: Originator:

SN16 System Info


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4205 MDHNWDCAL sysinfo description : Transient alarm on SN16 1 = Source code line 2 = Error type 3 = Device type 4 = High level originator 5 = High level code line 6 = Ubex alarm register 7 = PLLH alarm registers 8 = SN Control and Inpiu Block alarm registers 9 = SN Output and sense registers 10 = SN Alarmed 8Mb/s lines n. 16..24 11 = SN Alarmed 8Mb/s lines n. 0..15 12 = SN Alarmed 2Mb/s lines towards PPXX 13 = SN Comparison alarmed lines n. 16..24 14 = SN Comparison alarmed lines n. 0..15 15 = Other alarms 16 = Not used 17 = Not used 18 = Not used 19 = Not used 20 = Not used 21 = Not used 22 = Not used 23 = Not used 24 = Not used 25 = Not used 26 = Not used 27 = Not used 28 = Not used 29 = Not used 30 = Not used 31 = Not used 32 = Not used ##fine##

862

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

SYSINFO_ID: 110
SYSTEM INFO REPORT: Originator:

XXGP AUDIT NO ANSWER


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4951 TDHGPDCDE sysinfo description : This notification occurs when MDHXX doesn't answer to five consecutive Audit messages 1 = line number in source module 2 = Not used. 3 = Not used. 4 = Not used. 5 = Not used. 6 = Not used. 7 = Not used. 8 = Not used. 9 = Not used. 10 = Not used. 11 = Not used. 12 = Not used. 13 = Not used. 14 = Not used. 15 = Not used. 16 = Not used. 17 = Not used. 18 = Not used. 19 = Not used. 20 = Not used. 21 = Not used. 22 = Not used. 23 = Not used. 24 = Not used. 25 = Not used. 26 = Not used. 27 = Not used. 28 = Not used. 29 = Not used. 30 = Not used. 31 = Not used. 32 = Not used. ##fine##

A30808-X3247-K240-3-7619

863

Outputs OML:BSC

Base Station Controller

SYSINFO_ID: 112
SYSTEM INFO REPORT: Originator:

TRAU ALIGNMENT FAILED INFO


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4752 TDHTRDCMC sysinfo description : This system info is output every time that an alignment is already failed and a new alignment attempt is done, but something goes wrong. 1 = Current event that determinated the last alignment TRAU_TMOUT 0x01 timeout occurred TRAU_SMENBL 0x02 status manager ENABLE command TRAU_SMDSBL 0x03 status manager DISABLE command TRAU_SMLOCK 0x04 status manager LOCK command TRAU_SMUNLOCK 0x05 status manager UNLOCK command TRAU_SWALGOK 0x06 successful end of SW alignment TRAU_SWALGFAIL 0x07 failed SW alignment TRAU_SWREFRESH 0x08 refresh from SW alignment process TRAU_SWSTRDWLD 0x09 started download of NE TRAU_SWALGEND 0x0a successful end of download TRAU_SWACTREQ 0x0b software activation request TRAU_LINKUP 0x0c link transition down->up TRAU_LINKDOWN 0x0d link transition up->down TRAU_RCVNACK 0x0e received nack reply during alignment TRAU_MSGDSBL 0x0f notification of TRAU disabled TRAU_MSGENBL 0x10 notification of TRAU enabled TRAU_STOPEVREP 0x11 ack to "Stop sending event report" TRAU_RSTEVREP 0x12 ack to "Restart sending event report" TRAU_RESETRES 0x13 ack to "Reset resource message" TRAU_ASUBTMT 0x14 failed elementary procedure TRAU_ASUBSENDERR 0x15 failed elementary procedure TRAU_AUDITFAIL 0x16 audit of state is not consistent TRAU_ALGNREQ 0x17 alignment request from system TRAU_DBDHKLV 0x18 periodical execution audit from dhdb TRAU_DBDHERR 0x19 failed dbdh procedure TRAU_DBDHREQ 0x1a request queued to dbdh TRAU_DBDHRPL 0x1b reply received from dbdh TRAU_ADMOK 0x1c ackwnoledge of an administrative state procedure TRAU_GIRPL 0x1d consequently a GI SYNCO request the Trau replies. 2 = event that determinated the last alignment in the TRAU main table (the meaning are the same listed above). 3 = current state of main state machine 4 = current state of alignment state machine 5 = TRAU operational state from SM
864 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Note that this field also marks the existence of a certain instance, in case of not equipped instances the value is NO_OPERATIONAL_STATE (0). 6 = TRAU administrative state from SM 7 = TRAU operational state from Abis 8 = TRAU administrative state from Abis 9 = if equal to 0 no shut-down on TRAUm is active otherwise is expiring a timeoutNot used 10 = TRAU availability status from Abis 11 = temporary operational state during TRAU alignment 12 = TRAU usage state (updated by shut-down or get commands only) 13 = identifier for the PCMA alarmNot used 14 = identifier for the PCMA temporary alarm 15 = control alignment of administrative state 16 = control sequence of state audit of Asub (High part) 17 = control sequence of state audit of Asub (Low part) 18 = DBA Server current evolving procedure: object mnemonic involved in the procedure 19 = DBA Server current evolving procedure: first address of the object involved in the procedure 20 = DBA Server current evolving procedure: second address of the object involved in the procedure 21 = DBA Server current evolving procedure: third address of the object involved in the procedure 22 = DBA Server current evolving procedure: fourth address of the object involved in the procedure 23 = DBA Server current evolving procedure: command to be forwarded to DBA Server 24 = counter of the TRAU_FAILEDPROC events for filtering (High part) 25 = counter of the TRAU_FAILEDPROC events for filtering (Low part) 26 = TRUE if failed_align persist. 27 = check if the conf. alarm is already present (High part) 28 = check if the conf. alarm is already present (Low part) 29 = internal error used as return from the function calls (High part) 30 = internal error used as return from the function calls (Low part) 31 = Not used 32 = Not used ##fine##

A30808-X3247-K240-3-7619

865

Outputs OML:BSC

Base Station Controller

SYSINFO_ID: 113
SYSTEM INFO REPORT: Originator:

MIT_ALREADY_IN_PROGRESS
<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 511 MOSIWROCO sysinfo description : The error is issued when interworking task receives another MIT Alignment request when another process is running 1= Used by designer to locate source code line 2= Used by designer to locate mnemonic value (TRAU or BTSM) 3= Used by designer to locate Network Element address . 4= Not used 5= Not used 6= Not used 7= Not used 8= Not used 9= Not used 10 = Not used 11 = Not used 12 = Not used 13 = Not used 14 = Not used 15 = Not used 16 = Not used 17 = Not used 18 = Not used 19 = Not used 20 = Not used 21 = Not used 22 = Not used 23 = Not used 24 = Not used 25 = Not used 26 = Not used 27 = Not used 28 = Not used 29 = Not used 30 = Not used 31 = Not used 32 = Not used ##fine##

866

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

SYSINFO_ID: 114
SYSTEM INFO REPORT: Originator:

Throttling Condition Started


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 3702 USMARECTH sysinfo description : This system info notify that on PCUC the throttling management has started because too many Error Collector calls (50) has been received in 10 ms. 1 = Alarm Reporting ACTION that determined the output of this system info (developer oriented). 2 = Not used. 3 = Not used. 4 = Not used. 5 = Not used. 6 = Not used. 7 = Not used. 8 = Not used. 9 = Not used. 10 = Not used. 11 = Not used. 12 = Not used. 13 = Not used. 14 = Not used. 15 = Not used. 16 = Not used. 17 = Not used. 18 = Not used. 19 = Not used. 20 = Not used. 21 = Not used. 22 = Not used. 23 = Not used. 24 = Not used. 25 = Not used. 26 = Not used. 27 = Not used. 28 = Not used. 29 = Not used. 30 = Not used. 31 = Not used. 32 = Not used.

A30808-X3247-K240-3-7619

867

Outputs OML:BSC

Base Station Controller

SYSINFO_ID: 115
SYSTEM INFO REPORT: Originator:

Throttling Condition Ended


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 3702 USMARECTH sysinfo description : This system info notify that on PCUC the throttling management has ended because, because all the pending Error Collector calls have been processed. 1 = Alarm Reporting ACTION that determined the output of this system info (developer oriented). 2 = Not used. 3 = Not used. 4 = Not used. 5 = Not used. 6 = Not used. 7 = Not used. 8 = Not used. 9 = Not used. 10 = Not used. 11 = Not used. 12 = Not used. 13 = Not used. 14 = Not used. 15 = Not used. 16 = Not used. 17 = Not used. 18 = Not used. 19 = Not used. 20 = Not used. 21 = Not used. 22 = Not used. 23 = Not used. 24 = Not used. 25 = Not used. 26 = Not used. 27 = Not used. 28 = Not used. 29 = Not used. 30 = Not used. 31 = Not used. 32 = Not used. ##fine##

868

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

SYSINFO_ID: 116
SYSTEM INFO REPORT: Originator:

TRAU-AMR But Pooling Disabled Info


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4752 TDHTRDCMC sysinfo description : This system info is output when an alignment procedure is starting for a TRAU-AMR, but the pooling is disabled on it. It must be verified the TRAU DB configuration and SW load with the one stored in the BSC. This system info is output only after the relative Failure Event Report and each time a TRAU alignment is attempted. 1 = source code line (developer oriented) 2 = DBA function call result (developer oriented) 3 = event that determined the last alignment 4 = current state of main state machine 5 = current state of alignment state machine 6 = TRAU operational state from SM Note that this field also marks the existence of a certain instance, in case of not equipped instances the value is NO_OPERATIONAL_STATE (0). 7 = TRAU administrative state from SM 8 = TRAU operational state from Abis 9 = TRAU administrative state from Abis 10 = if equal to 0 no shut-down on TRAUm is active otherwise is expiring a timeout 11 = TRAU availability status from Abis 12 = temporary operational state during TRAU alignment 13 = TRAU usage state (updated by shut-down or get commands only) 14 = identifier for the PCMA alarm 15 = identifier for the PCMA temporary alarm 16 = control alignment of administrative state 17 = control sequence of state audit of Asub (High part) 18 = control sequence of state audit of Asub (Low part) 19 = DBA Server current evolving procedure: object mnemonic involved in the procedure 20 = DBA Server current evolving procedure: first address of the object involved in the procedure 21 = DBA Server current evolving procedure: second address of the object involved in the procedure 22 = DBA Server current evolving procedure: third address of the object involved in the procedure 23 = DBA Server current evolving procedure: fourth address of the object involved in the procedure 24 = DBA Server current evolving procedure: command to be forwarded to DBA Server 25 = counter of the TRAU_FAILEDPROC events for filtering (High part) 26 = counter of the TRAU_FAILEDPROC events for filtering (Low part) 27 = TRUE if failed_align persist. 28 = check if the conf. alarm is already present (High part) 29 = check if the conf. alarm is already present (Low part) 30 = Not used 31 = Not used
A30808-X3247-K240-3-7619 869

Outputs OML:BSC

Base Station Controller

32 = Not used ##fine##

870

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

SYSINFO_ID: 117
SYSTEM INFO REPORT: Originator:

DISK System Info


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4305 MDH40IOSC sysinfo description : System info from DK40 Device Handler, used by the designer to identify the cause of an error from the DK40 subsystem. These System info messages dump several memory locations on MPCC or on the DK40 DUAM. They are output in two cases: 1) error on a single DK40: a system info message of type 0 (see description of word 1) is output, followed by three system info messages (type 1, 2 and 3) dumping the DUAM of the failed DK40 2) mismatch between the two DK40 during a FS operation: a system info message of type 0 is output, followed by six system info messages dumpina the DUAMs of both DK40 cards. 1= System info type: 0 - DK40 DH Status 1 - DK40 DUAM dump 2 - Message to DK40 3 - Response from DK40 4 - Information from DK40 FW 0 - Used by the designer to locate the instruction (file id of first calling instruction). 1 - Disk Formatted 2, 3 - Src System + Dst System (DDSS) 0 - Used by the designer to locate the instruction (line of first calling instruction). 1 - StdbyStatus 2, 3 - Flags + Priority (PPFF) 0 - Used by the designer to locate the instruction (file id of second calling instruction). 1 - % Disk Free Space 2,3 - Src Mbx 0 - Used by the designer to locate the instruction (line of second calling instruction). 1 - Diag Resp 2, 3 - Spare 0 0 - Used by the designer to locate the instruction (file id of third calling instruction). 1 - OpCode 2, 3 - Spare 1 0 - Used by the designer to locate the instruction (line of third calling instruction). 1 - Fs Busy 2, 3 Dest Mbx 0 - Used by the designer to locate the instruction (file id of fourth calling instruction). 1 - OpRetCode 2 - Stamp Lo 0 -Used by the designer to locate the instruction (line of fourth calling instruction).
871

2= 3= 4= 5= 6= 7= 8= 9=

A30808-X3247-K240-3-7619

Outputs OML:BSC

Base Station Controller

10 =

11 =

12 = 13 =

14 = 15 = 16 = 17 = 18 = 19 = 20 = 21 = 22 = 23 = 24 = 25 = 26 = 27 =
872

1 - Fid 2 - Stamp Hi 0 - Used by the designer to identify the task status 1 - HW Semaphore 0 2 - Signal Type (C9) 3 - Signal Type (CA) 0 - Used by the designer to identify the task status 1 - HW Semaphore 1 2 - Operation Code 3 - Operation Result (0 = OK, 1 = Failed) 0 - Used by the designer to identify the task status 1 - HW Semaphore 2 2, 3 - Datalen 0 - Used by the designer to identify the task status 1 - HW Semaphore 3 2 - Msg Data 3 - Operation Data 0 - Used by the designer to identify the task status 1 - HW Semaphore 4 2, 3 - Msg Data 0 - Used by the designer to identify the task status 1 - HW Semaphore 5 2, 3 - Msg Data 0 - Used by the designer to identify the task status 1 - DUAM Dump 2, 3 - Msg Data 0 - DISK object state 1 - DUAM Dump 2, 3 - Msg Data 0 - DK40 0 object state 1 - DUAM Dump 2, 3 - Msg Data 0 - DK40 1 object state 1 - DUAM Dump 2, 3 - Msg Data 0 - Current object 1 - DUAM Dump 2, 3 - Msg Data 0 - Current event 1 - DUAM Dump 2, 3 - Msg Data 0 - Command sent to DK40 0 1 - DUAM Dump 2, 3 - Msg Data 0 - Command sent to DK40 1 1 - DUAM Dump 2, 3 - Msg Data 0 - Result from DK40 0 1 - DUAM Dump 2, 3 - Msg Data 0 - Result from DK40 1 1 - DUAM Dump 2, 3 - Msg Data 0 - Data from DK40 0 1 - DUAM Dump 2, 3 - Msg Data 0 - Data from DK40 1
A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

1 - DUAM Dump 2, 3 - Msg Data 28 = 0 - Standby status of DK40 0 1 - DUAM Dump 2, 3 - Msg Data 29 = 0 - Standby status of DK40 1 1 - DUAM Dump 2, 3 - Msg Data 30 = 1 - DUAM Dump 2, 3 - Msg Data 31 = 1 - DUAM Dump 2, 3 - Msg Data 32 = 1 - DUAM Dump 2, 3 - Msg Data ##fine##

A30808-X3247-K240-3-7619

873

Outputs OML:BSC

Base Station Controller

SYSINFO_ID: 118
SYSTEM INFO REPORT: Originator:

CHANGE VERSION INFO


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 507 MSDBASDL sysinfo description : A Change Version procedure is occurred. Add Info are related to involved processors and their possibles values are the following: -If value is 0 the processor is not involved in the Change Version Procedure -If value is 1 the processor is involved for different executable entities. -If value is 2 the processor is involved for different patch entities. 1 = Used by the designer to indicate the values related to MPCC processor 2 = Used by the designer to indicate the values related to IXLT processor 3 = Used by the designer to indicate the values related to TDPC processor 4 = Used by the designer to indicate the values related to PPCC processor 5 = Used by the designer to indicate the values related to PPLD processor 6 = Used by the designer to indicate the values related to PPCU processor 7 = Used by the designer to indicate the values related to PPXL processor 8 = Used by the designer to indicate the values related to PPXU processor 9 = Not used 10 = Not used 11 = Not used 12 = Not used 13 = Not used 14 = Not used 15 = Not used 16 = Not used 17 = Not used 18 = Not used 19 = Not used 20 = Not used 21 = Not used 22 = Not used 23 = Not used 24 = Not used 25 = Not used 26 = Not used 27 = Not used 28 = Not used 29 = Not used 30 = Not used 31 = Not used 32 = Not used
874 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

##fine##

A30808-X3247-K240-3-7619

875

Outputs OML:BSC

Base Station Controller

SYSINFO_ID: 119
SYSTEM INFO REPORT: Originator:

PPXU/PPXL FIRMAWARE TEST FAILURE


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4513 MDHXXLUEH sysinfo description : This system info is issued when the PPXL or PPXU FW self-test (after micro reset) fails. 1 = Line 2 = Error 3 = Byte 0 of DUAM area command 4 = Byte 1 of DUAM area command 5 = Byte 2 of DUAM area command 6 = Byte 3 of DUAM area command 7 = Byte 1 in area command (mpcc to ppxx) 8 = Byte 4 in area command (mpcc to ppxx) 9 = Byte 7 in area command (mpcc to ppxx) 10 = Byte 8 in area command (mpcc to ppxx) 11 = Byte 11 in area command (mpcc to ppxx) 12 = Byte 16 in area command (mpcc to ppxx) 13 = Byte 17 in area command (mpcc to ppxx) 14 = Byte 20 in area command (mpcc to ppxx) 15 = Byte 21 in area command (mpcc to ppxx) 16 = Byte 86 in area command (mpcc to ppxx) 17 = Byte 87 in area command (mpcc to ppxx) 18 = Byte 88 in area command (mpcc to ppxx) 19 = Byte 89 in area command (mpcc to ppxx) 20 = Byte of Status 21 = Byte of Retry 22 = Byte of expTm 23 = not used 24 = not used 25 = not used 26 = not used 27 = not used 28 = not used 29 = not used 30 = not used 31 = not used 32 = not used ##fine##

876

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

SYSINFO_ID: 120
SYSTEM INFO REPORT: Originator:

CHECKSUM_PID_FAILURE
<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 623 MSDRIBSHT sysinfo description : This System Info is issued when Remote Inventory task performs a checksum on retrieved Pid data and an Unsuccessful result is occurred (Pid corrupted case). 1 = Source Code Line 2 = First Pid Element (First byte of Format version Pid structure) 3 = Second Pid element(Second byte of Format version Pid structure) 4 = Type of card 5 = Instance number of card 6 = Not used 7 = Not used 8 = Not used 9 = Not used 10 = Not used 11 = Not used 12 = Not used 13 = Not used 14 = Not used 15 = Not used 16 = Not used 17 = Not used 18 = Not used 19 = Not used 20 = Not used 21 = Not used 22 = Not used 23 = Not used 24 = Not used 25 = Not used 26 = Not used 27 = Not used 28 = Not used 29 = Not used 30 = Not used 31 = Not used 32 = Not used ##fine##

A30808-X3247-K240-3-7619

877

Outputs OML:BSC

Base Station Controller

SYSINFO_ID: 130
SYSTEM INFO REPORT: Originator:

SNAP System Info


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:

Case of XXXX = 4202 MDHNWDCSC sysinfo description : SNAP permanent failure or SNAP recovery causing 1 = Source code line (developer oriented) 2 = Error type (developer oriented) 3 = Device type (developer oriented) 4 = High level originator (developer oriented) 5 = High level code line (developer oriented) 6 = UBEX alarm register (low byte); Editions of the two PLLH cards (high byte); 7 = (developer oriented) PLLH alarm register (high byte); PLLH alarm type (low byte); 8 = (developer oriented) SNAP control block register (high byte); SNAP input alarm register (low byte); 9 = (developer oriented) SNAP output alarm register (high byte); Sense point register (low byte); 10 = Parity alarm on SNAP 8Mb/s lines 0 .. 15 11 = Parity alarm on SNAP 8Mb/s lines 16 .. 31 12 = Parity alarm on SNAP 8Mb/s lines 32 .. 47 13 = Parity alarm on SNAP 8Mb/s lines 48 .. 59 14 = Comparison alarm on SNAP 8Mb/s lines 0 .. 15 15 = Comparison alarm on SNAP 8Mb/s lines 16 .. 31 16 = Comparison alarm on SNAP 8Mb/s lines 32 .. 47 17 = Comparison alarm on SNAP 8Mb/s lines 48 .. 59 18 = (developer oriented) FIFO flag status register 19 = (developer oriented) Alarmed Bank 20 = (developer oriented) Trap of CRAM address for Speech Ram data error 21 = (developer oriented) Trap of CRAM address for Speech Ram address error 22 = (developer oriented) Trap of CRAM address for Control Ram data error 23 = (developer oriented) FIFO write pointer 24 = (developer oriented) SNAP output block other alarms register 25 = (developer oriented) SNAP PLD register (low byte); FPGA load register (high byte) 26 = (developer oriented) SNAP FPGA firmware version; 27 = (developer oriented) Other alarms 28 = Not used 29 = Not used 30 = Not used 31 = Not used 32 = Not used

878

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

SYSINFO_ID: 131
SYSTEM INFO REPORT: Originator:

PPXL Unsuccessful Link Configuration


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4515 MDHXXLUSM sysinfo description : This notification is provided when the PPXL SW answers NACK to a LAPD/SS7 link configuration command (delete or create). 1 = line number 2 = err code: 0x92 = CONFIG_LAPD_NACK 0x93 = CONFIG_SS7L_NACK 3 = more significant byte: first byte of the PPXL SW response (OPCODE) 0x51 = CREATE_LAPD_LINK_NACK 0x53 = CREATE_SS7_LINK_NACK 0x55 = DELETE_LAPD_LINK_NACK 0x57 = DELETE_SS7_LINK_NACK less significant byte: second byte of the PPXL SW response number of link involved = up to 2 in case of err code = CONFIG_SS7L_NACK up to 32 in case of err code = CONFIG_LAPD_NACK 4 = for internal use only 5 = for internal use only 6 = for internal use only 7 = for internal use only 8 = for internal use only 9 = for internal use only 10 = for internal use only 11 = for internal use only 12 = for internal use only 13 = for internal use only 14 = for internal use only 15 = for internal use only 16 = for internal use only 17 = for internal use only 18 = for internal use only 19 = for internal use only 20 = for internal use only 21 = for internal use only 22 = for internal use only 23 = for internal use only 24 = for internal use only 25 = for internal use only 26 = for internal use only 27 = for internal use only
A30808-X3247-K240-3-7619 879

Outputs OML:BSC

Base Station Controller

28 = for internal use only 29 = for internal use only 30 = for internal use only 31 = for internal use only 32 = ##fine##

880

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

SYSINFO_ID: 132
SYSTEM INFO REPORT: Originator:

PPXL/PPXU System Info


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4512 MDHXXLUDE 4514 MDHXXLUSA sysinfo description : This system info is issued when: case a (MDHXXLUSA): PPXU/PPXL Agent (residing on card Pentium) puts the card into Out Of Service Faulted internal state (because of a Non Maskable Interrupt or another card problem) and moves some information to PPXX DH on MPCC; in this case this system info may be repeated twice or three times and information contained in further system info are reported here with the notation "second sysinfo" or "third sysinfo"; case b (MDHXXLUDE): during PPXL/PPXU diagnostic (if test report lenght is greater than 16 bytes); case c (MDHXXLUDE): during a PPxx DH check of PPXU alarms (potentially due to Network card), if more than one card are alarmed and Network switch is induced. 1 = case a (first sysinfo): high byte: if PPXX DH command is "Give Status" (card SW check): required action, whose possible values are: 1 = Disable; 2 = Disable with automatic Recovery (Diagnostic Test); 3 = Warning only For every other command: command code. Possible values of PPxx Agent answers: Force In Service Executed 0x61 Force Out Of Service Idle Executed 0x62 Get Info 0x71 low byte: system info length (in bytes) case a (second sysinfo): In case of missing download of RLC blocks: bit mask of failed channels (PDT) related to ABIC-11 In case of NMI: low byte = fourth byte of MUSYCC add info; high byte: time stamp. Otherwise: not used case a (third sysinfo): In case of invalid AbIC alarm report: bit mask of failed channels (PDT) related to ABIC-11
A30808-X3247-K240-3-7619 881

Outputs OML:BSC

Base Station Controller

In case of NMI: OS trap Otherwise: not used 2= cases b, c: source code line case a (first sysinfo): high byte: type of PPXU/PPXL problem. Possible values: 0x01 = FPGA loopback problem 0x02 = MPCC or TDPC DUAM problem 0x03 = MPCC DUAM problem 0x04 = TDPC DUAM problem 0x05 = NMI during access to MPCC DUAM 0x06 = NMI during access to TDPC DUAM 0x07 = CPU power lack (1.8 V check) 0x08 = MUSYCC Init problem 0x0A = MUSYCC alarm 0x0D = PPXX fixed problem (NMI Handler) 0x0E = Watch Dog Timer problem (NMI Handler) 0x0F = PPXX HW MULTI problem (NMI Handler) 0x10 = card fault (with delayed action and PPxx Init) 0x11 = card fault (with PPxx Init) 0x20 = MUNICH Init problem (PPXU only) 0x22 = MUNICH reset problem (PPXU only) 0x24 = MUNICH alarm (PPXU only) 0x27 = IRQ1 AbIC interrupt not working (PPXU only) 0x28 = Checksum test of AbIC code memory failure (corruption of some memory locations) (PPXU only) 0x29 = Failure during read/write test of AbIC data memory locations (PPXU only) 0x2A = lost of DMA4 INTR DSP interrupt synchronization (PPXU only) 0x2B = lost of DMA5 INTR DSP interrupt synchronization (PPXU only) 0x2C = ABIC INTR DSP synchronization failure (missing or delayed interrupt) (PPXU only) 0x2D = Invalid internal RLC blocks coming from PCUX (PPXU only) 0x2E = No internal RLC blocks received by AbIC from PCUX (PPXU only) 0x2F = Internal RLC blocks coming from PCUX were received too late (delay greater than 400 ms) (PPXU only) 0x30 = DSP not correctly loaded (PPXU only) 0x31 = number of DSP Sw exceptions higher than a threshold (NMI Handler) (PPXU only) 0x32 = SW exception (out of range access) (NMI Handler) 0x33 = DSP HW exception (NMI Handler) (PPXU only) 0x34 = Invalid AbIC Alarm Report (PPXU only) low byte: involved processor (1 = AbIC, 2 = PCUX) case a (second sysinfo): In case of missing download of RLC blocks: bit mask of failed channels (PDT) related to ABIC-12 In case of NMI (before processing last exception): low byte = not used; high byte = NMI Source watchdog or SERR# signal (bit 7 is set if a system board agent, that is PCI device or main memory, detects a system board error, bit 6 is set if an watchdog time out is asserted) Otherwise: not used case a (third sysinfo): In case of invalid AbIC alarm report: bit mask of failed channels (PDT) related to ABIC-12 In case of NMI: OS trap
882 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Otherwise: not used case b: low byte = type of detected failure, high byte = other information possible values for phase 1: low byte: 0x03 = MPCC DUAM check failure - high byte: not used; low byte: 0x04 = TDPC DUAM check failure - high byte: not used; low byte: 0x05 = NMI during access to MPCC DUAM - high byte: bit mask reporting sources of NMI (0x10 = transmission conflicts towards SNAP (DSP / MUSYCC), 0x20 = Watch Dog, 0x40 = data parity error in read operation from DUAM, 0x80 = parity error on PCI Bus); low byte: 0x06 = NMI during access to TDPC DUAM - high byte: bit mask reporting data parity alarm on bits 0-7 (bit mask = 0x01), on bits 8-15 (bit mask = 0x02), on bits 16-23 (bit mask = 0x04), on bits 24-31 (bit mask = 0x08); low byte: 0x07 = lack of CPU power (1.8 V) - high byte: not used; possible values for phase 2: low byte: 0x01 = failure of FPGA loopback access - high byte: not used; low byte: 0x08 = problem in MUSYCC Initialisation - high byte: not used; low byte: 0x09 = problem during MUSYCC internal loop - high byte: not used; low byte: 0x0A = SERR (address parity error) alarm on MUSYCC - high byte: not used; possible values for phase 3: low byte (used for PPXU only): 0x20 = MUNICH Initialization problem during internal MUNICH loop or MUNICH-DSP loop - high byte: not used; low byte (used for PPXU only): 0x23 = failure during MUNICH internal loop test - high byte: number of faulted channels; low byte: 0x25 = failure of DSP setting to MUNICH-DSP loop mode or failure of MUNICH-DSP loop test - high byte (PPXU only): location with uncorrect value (2 -> DSP address = 0x8002, 4 -> DSP address = 0x8004) or 0xFF -> meaningless; low byte (PPXU only): 0x26 = failure of DSP setting to MUNICH-FPGA loop mode or failure of MUNICH-FPGA loop test - high byte (PPXU only): location with uncorrect value (2 -> DSP address = 0x8002, 4 -> DSP address = 0x8004) or 0xFF -> meaningless. 3= case c: bit mask of alarmed cards case a (first sysinfo): In case of FPGA loopback failure (access problems), CPU power lack, Munich or Musycc alarm, MPCC or TDPC DUAM problems or AbIC not severe problems: PPXU/PPXL Agent originator (identifying source). In case of RTE operating system problems: error identifier. Otherwise: source code line number case a (second sysinfo): In case of missing download of RLC blocks: bit mask of failed channels (PDT) related to ABIC-13 In case of NMI (before processing last exception): low byte = PIIX4 PCI Status: bit 6 SERRS -> is set when PIIX4 asserts the SERR# signal. bit 5 MAS -> PIIX4 as a master, it generates a master-abort. bit 4 RTA -> received target-abort status bit 3 STA -> signaled target-abort status bit 2:1 DEVSEL# -> timing status (DEVT) high byte: SNAP configuration register Otherwise: not used case a (third sysinfo): In case of invalid AbIC alarm report:
A30808-X3247-K240-3-7619 883

Outputs OML:BSC

Base Station Controller

bit mask of failed channels (PDT) related to ABIC-13 In case of NMI: OS trap Otherwise: not used case b: used in the following PPXU failure cases only: case Munich Init: number of source code line (Agent) cases Munich-DSP and Munich-FPGA loops: number of source code line (Agent) 4= case c: bit mask of PPxx cards to be checked case a (first sysinfo): Low byte: 1) In case of Munich Init problem (PPXU only): specific failure (0 = wrong input parameter, 1 = Munich Reset problem, 2 = port configuration failure, 3 = Channel Init failure) 2) AbIC problems: line of source code 3) In case of unsuccessful DSP load (PPXU only): bit mask of failed DSP 4) in case of NMI: origin of the problem (0x17 = NMI) 5) in case of RTE problems: low byte of originator (entire values of source items: 0x3E0= NOSKNMSEH; 0x3D6 = YOSKNMSEH) 6) Otherwise: not used High byte: 1) In case of unsuccessful DSP load: bit mask of failed AbIC (first 8 cores) 2) NMI: origin of the problem 3) RTE problems: high byte of originator 4) Otherwise: not used case a (second sysinfo): In case of missing download of RLC blocks: bit mask of failed channels (PDT) related to ABIC-14 In case of NMI (before processing last exception): low byte: PIC in service high byte: PIC in service Otherwise: not used case a (third sysinfo): In case of invalid AbIC alarm report: bit mask of failed channels (PDT) related to ABIC-14 In case of NMI: OS trap Otherwise: not used case b: used in the PPXU following cases: case Munich Init: 0x00 = uncorrect input argument of routine, 0x01 = Munich reset failure, 0x02 = port configuration failure, 0x03 = channel init failure cases of failure of Munich-DSP loop mode set and of MUNICH-FPGA loop mode set: faulty DSP (bit mask:0x01 = DSP-0, 0x02 = DSP-1, 0x04 = DSP-2, 0x08 = DSP-3) cases of MUNICH-DSP and MUNICH-FPFA loop failures: number of faulty channels case c: number of suspected PPxx case a (first sysinfo): Low byte: 1) In case of unsuccessful DSP load: bit mask of failed AbIC (cores from 8 to 15)
A30808-X3247-K240-3-7619

5=

884

Base Station Controller

Outputs OML:BSC

2) Case of IRQ1 interrupt not working: IRQ1 state (1 = received; 0 = not received) 3) in case of NMI: origin of the problem 4) in case of RTE problems: RTE reserved code for error type (low byte) 5) Otherwise: not used High byte: 1) In case of AbIC not severe problems (Failure during read/write test of AbIC data memory locations, lost of DMA4 (or DMA5) INTR DSP interrupt synchronization, ABIC INTR DSP synchronization failure (missing or delayed interrupt), invalid internal RLC blocks coming from PCUX , no internal RLC blocks received by AbIC from PCUX, internal RLC blocks coming from PCUX were received too late): bit mask of failed DSP 2) In case of unsuccessful DSP load (PPXU only): values read on AbIC-0 (low byte of value) 3) in case of NMI: origin of the problem 4) in case of RTE problems: RTE reserved code for error type (high byte) 5) Otherwise: not used case a (second sysinfo): In case of missing download of RLC blocks: bit mask of failed channels (PDT) related to ABIC-15 In case of NMI (before processing last exception): low byte = interrupts and NMI register high byte = FPGA conflict report (PPXU -> transmission conflict among DSP and MUSYCC; PPXL -> conflict between MUSYCC ports) Otherwise: not used case a (third sysinfo): In case of invalid AbIC alarm report: bit mask of failed channels (PDT) related to ABIC-15 In case of NMI: OS trap Otherwise: not used case b: used in the cases of MUNICH-DSP and MUNICH-FPGA loop mode set (PPXU only): bit mask of faulty AbIC (0x0001 = AbIC-0, 0x0002 = AbIC-1, 0x0004 = AbIC-2, 0x0008 = AbIC3,.., 0x0080 = AbIC-7, 0x0100 = AbIC-8, 0x0200 = AbIC-9,.., 0x8000 = AbIC-15) 6= case c: not used case a (first sysinfo): 1) In case of invalid RLC blocks bit mask of failed channels (PDT) related to ABIC-0 2) In case of IRQ1 interrupt not working: alarm status of AbIC-0 3) In case of unsuccessful DSP load: low byte: values read on AbIC-0 (high byte of value) high byte: values read on AbIC-1 (low byte of value) 4) in case of NMI: origin of the problem 5) Otherwise: not used case a (second sysinfo): In case of too late download of RLC blocks: bit mask of failed channels (PDT) related to ABIC-0 In case of NMI (before processing last exception): low byte = TDPC alarm status (first byte) high byte = TDPC alarm status (second byte) Otherwise: not used case a (third sysinfo): In case of failure of checksum test of AbIC code memory:
A30808-X3247-K240-3-7619 885

Outputs OML:BSC

Base Station Controller

bit mask of failed AbIC In case of NMI: OS trap Otherwise: not used case b: used in the following cases (PPXU only): case Munich internal loop: bit mask reporting faulty channels (0x0001 = chan. 0, 0x0002 = chan. 1,..,0x8000 = chan. 15) cases MUNICH-DSP and MUNICH-FPGA loop mode set: value read on AbIC-0 cases MUNICH-DSP and MUNICH-FPGA loop failure: bit mask of faulty channels (0-15) 7= case c: not used case a (first sysinfo): 1) In case of invalid RLC blocks: bit mask of failed channels (PDT) related to ABIC-1 2) In case of IRQ1 interrupt not working: alarm status of AbIC-1 3) In case of unsuccessful DSP load: low byte: values read on AbIC-1 (high byte of value) high byte: values read on AbIC-2 (low byte of value) 4) in case of NMI: origin of the problem 5) Otherwise: not used case a (second sysinfo): In case of too late download of RLC blocks: bit mask of failed channels (PDT) related to ABIC-1 In case of NMI (before processing last exception): low byte = TDPC alarm status (third byte) high byte = TDPC alarm status (fourth byte). Otherwise: not used case a (third sysinfo): In case of lost of DMA4 - DSP interrupt synchronization: bit mask of failed AbIC In case of NMI: OS trap Otherwise: not used case b: used in the following cases (PPXU only): case Munich internal loop: bit mask reporting faulty channels (0x0001 = chan. 16, 0x0002 = chan. 17,..,0x8000 = chan. 31) cases MUNICH-DSP and MUNICH-FPGA loop mode set: value read on AbIC-1 cases MUNICH-DSP and MUNICH-FPGA loop failure: bit mask of faulty channels (16-31) 8= case c: not used case a (first sysinfo): 1) In case of invalid RLC blocks: bit mask of failed channels (PDT) related to ABIC-2 2) In case of IRQ1 interrupt not working: alarm status of AbIC-2 3) In case of unsuccessful DSP load: low byte: values read on AbIC-2 (high byte of value) high byte: values read on AbIC-3 (low byte of value) 4) in case of NMI: time stamp 5) Otherwise: not used case a (second sysinfo):
886 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

In case of too late download of RLC blocks: bit mask of failed channels (PDT) related to ABIC-2 In case of NMI (before processing last exception): DSP Hpi Reg Int (this register stores the component which has sent the interrupt to the MUNICH) Otherwise: not used case a (third sysinfo): In case of lost of DMA5 - DSP interrupt synchronization: bit mask of failed AbIC In case of NMI: OS trap Otherwise: not used case b: used in the following cases (PPXU only): case Munich internal loop: bit mask reporting faulty channels (0x0001 = chan. 32, 0x0002 = chan. 33,..,0x8000 = chan. 47) cases MUNICH-DSP and MUNICH-FPGA loop mode set: value read on AbIC-2 cases MUNICH-DSP and MUNICH-FPGA loop failure: bit mask of faulty channels (32-47) 9= case c: not used case a (first sysinfo): 1) In case of invalid RLC blocks: bit mask of failed channels (PDT) related to ABIC-3 2) In case of IRQ1 interrupt not working: alarm status of AbIC-3 3) In case of unsuccessful DSP load: low byte: values read on AbIC-3 (high byte of value) high byte: values read on AbIC-4 (low byte of value) 4) In case of NMI: time stamp 5) Otherwise: not used case a (second sysinfo): In case of too late download of RLC blocks: bit mask of failed channels (PDT) related to ABIC-3 In case of NMI (before processing last exception): DSP Hpi Comreg Register: the host processor can control the DSP resets (A_RS, B_RS, C_RS, D_RS), the HPI port resets (RESET) and the selection of the HPI port of each sub-core by writing the corresponding bits. Otherwise: not used case a (third sysinfo): In case of missing or delayed AbIC INTR DSP interrupt: bit mask of failed AbIC. In case of NMI: OS trap Otherwise: not used case b: used in the following cases (PPXU only): case Munich internal loop: bit mask reporting faulty channels (0x0001 = chan. 48, 0x0002 = chan. 49,..,0x8000 = chan. 63) cases MUNICH-DSP and MUNICH-FPGA loop mode set: value read on AbIC-3 cases MUNICH-DSP and MUNICH-FPGA loop failure: bit mask of faulty channels (48-63) 10 = case c: not used case a (first sysinfo): 1) In case of invalid RLC blocks: bit mask of failed channels (PDT) related to ABIC-4 2) In case of IRQ1 interrupt not working: alarm status of AbIC-4
887

A30808-X3247-K240-3-7619

Outputs OML:BSC

Base Station Controller

3) In case of unsuccessful DSP load: low byte: values read on AbIC-4 (high byte of value) high byte: values read on AbIC-5 (low byte of value) 4) In case of NMI: time stamp 5) Otherwise: not used case a (second sysinfo): In case of too late download of RLC blocks: bit mask of failed channels (PDT) related to ABIC-4 In case of NMI (before processing last exception): DSP Hpi Reg Cli; this register is used to clear the bits on the RegInt register. Otherwise: not used case a (third sysinfo): In case of NMI: OS trap Otherwise: not used case b: used in the following cases (PPXU only): case Munich internal loop: bit mask reporting faulty channels (0x0001 = chan. 64, 0x0002 = chan. 65,..,0x8000 = chan. 79) cases MUNICH-DSP and MUNICH-FPGA loop mode set: value read on AbIC-4 cases MUNICH-DSP and MUNICH-FPGA loop failure: bit mask of faulty channels (64-79) 11 = case c: not used case a (first sysinfo): 1) In case of invalid RLC blocks: bit mask of failed channels (PDT) related to ABIC-5 2) In case of IRQ1 interrupt not working: alarm status of AbIC-5 3) In case of unsuccessful DSP load: low byte: values read on AbIC-5 (high byte of value) high byte: values read on AbIC-6 (low byte of value) 4) In case of NMI: time stamp 5) Otherwise: not used case a (second sysinfo): In case of too late download of RLC blocks: bit mask of failed channels (PDT) related to ABIC-5 In case of NMI (before processing last exception): first and second bytes of MUNICH PCI command status (PPXU only) Otherwise: not used case a (third sysinfo): In case of NMI: OS trap Otherwise: not used case b: used in the following cases (PPXU only): case Munich internal loop: bit mask reporting faulty channels (0x0001 = chan. 80, 0x0002 = chan. 81,..,0x8000 = chan. 95) cases MUNICH-DSP and MUNICH-FPGA loop mode set: value read on AbIC-5 cases MUNICH-DSP and MUNICH-FPGA loop failure: bit mask of faulty channels (80-95) 12 = case c: not used case a (first sysinfo): 1) In case of invalid RLC blocks: bit mask of failed channels (PDT) related to ABIC-6
A30808-X3247-K240-3-7619

888

Base Station Controller

Outputs OML:BSC

2) In case of IRQ1 interrupt not working: alarm status of AbIC-6 3) In case of unsuccessful DSP load: low byte: values read on AbIC-6 (high byte of value) high byte: values read on AbIC-7 (low byte of value) 4) NMI case: index of last written value (low byte) and duam interrupt counter (high byte) 5) Otherwise: not used case a (second sysinfo): In case of too late download of RLC blocks: bit mask of failed channels (PDT) related to ABIC-6 In case of NMI (before processing last exception): third and fourth bytes of MUNICH PCI command status (PPXU only) Otherwise: not used case a (third sysinfo): In case of NMI: OS trap Otherwise: not used case b: used in the following cases (PPXU only): case Munich internal loop: bit mask reporting faulty channels (0x0001 = chan. 96, 0x0002 = chan. 97,..,0x8000 = chan. 111) cases MUNICH-DSP and MUNICH-FPGA loop mode set: value read on AbIC-6 cases MUNICH-DSP and MUNICH-FPGA loop failure: bit mask of faulty channels (96-111) 13 = case c: not used case a (first sysinfo): 1) In case of invalid RLC blocks: bit mask of failed channels (PDT) related to ABIC-7 2) In case of IRQ1 interrupt not working: alarm status of AbIC-7 3) In case of unsuccessful DSP load: low byte: values read on AbIC-7 (high byte of value) high byte: values read on AbIC-8 (low byte of value) 4) In case of NMI: NMI counters (both Init levels) 5) Otherwise: not used case a (second sysinfo): In case of too late download of RLC blocks: bit mask of failed channels (PDT) related to ABIC-7 In case of NMI (before processing last exception): first and second bytes of MUNICH additional information (PPXU only). Otherwise: not used case a (third sysinfo): In case of NMI: OS trap Otherwise: not used case b: used in the following cases (PPXU only): case Munich internal loop: bit mask reporting faulty channels (0x0001 = chan. 112, 0x0002 = chan. 113,..,0x8000 = chan. 127) cases MUNICH-DSP and MUNICH-FPGA loop mode set: value read on AbIC-7 cases MUNICH-DSP and MUNICH-FPGA loop failure: bit mask of faulty channels (112-127) 14 = case c: not used case a (first sysinfo): 1) In case of invalid RLC blocks:
889

A30808-X3247-K240-3-7619

Outputs OML:BSC

Base Station Controller

bit mask of failed channels (PDT) related to ABIC-8 2) In case of IRQ1 interrupt not working: alarm status of AbIC-8 3) In case of unsuccessful DSP load: low byte: values read on AbIC-8 (high byte of value) high byte: values read on AbIC-9 (low byte of value) 4) NMI case: exception counters for both init levels 5) Otherwise: not used case a (second sysinfo): In case of too late download of RLC blocks: bit mask of failed channels (PDT) related to ABIC-8 In case of NMI (before processing last exception): third and fourth bytes of MUNICH add info (PPXU only). Otherwise: not used case a (third sysinfo): In case of NMI: OS trap Otherwise: not used case b: used in the following cases (PPXU only): case Munich internal loop: bit mask reporting faulty channels (0x0001 = chan. 128, 0x0002 = chan. 129,..,0x8000 = chan. 143) cases MUNICH-DSP and MUNICH-FPGA loop mode set: value read on AbIC-8 cases MUNICH-DSP and MUNICH-FPGA loop failure: bit mask of faulty channels (128-143) 15 = case c: not used case a (first sysinfo): 1) In case of invalid RLC blocks: bit mask of failed channels (PDT) related to ABIC-9 2) In case of IRQ1 interrupt not working: alarm status of AbIC-9 3) In case of unsuccessful DSP load: low byte: values read on AbIC-9 (high byte of value) high byte: values read on AbIC-10 (low byte of value) 4) In case of NMI: extended originator (low) 5) Otherwise: not used case a (second sysinfo): In case of too late download of RLC blocks: bit mask of failed channels (PDT) related to ABIC-9 In case of NMI (before processing last exception): first and second bytes of MUSYCC PCI command status. Otherwise: not used case a (third sysinfo): In case of NMI: OS trap Otherwise: not used case b: used in the following cases (PPXU only): case Munich internal loop: bit mask reporting faulty channels (0x0001 = chan. 144, 0x0002 = chan. 145,..,0x8000 = chan. 159) cases MUNICH-DSP and MUNICH-FPGA loop mode set: value read on AbIC-9 cases MUNICH-DSP and MUNICH-FPGA loop failure: bit mask of faulty channels (144-159) 16 =
890

case c: not used case a (first sysinfo):


A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

1) In case of invalid RLC blocks: bit mask of failed channels (PDT) related to ABIC-10 2) In case of IRQ1 interrupt not working: alarm status of AbIC-10 3) In case of unsuccessful DSP load: low byte: values read on AbIC-10 (high byte of value) high byte: values read on AbIC-11 (low byte of value) 4) In case of NMI: extended originator (high) 5) Otherwise: not used case a (second sysinfo): In case of too late download of RLC blocks: bit mask of failed channels (PDT) related to ABIC-10 In case of NMI (before processing last exception): third and fourth bytes of MUSYCC PCI command status. Otherwise: not used case a (third sysinfo): In case of NMI: OS trap Otherwise: not used case b: used in the following cases (PPXU only): case Munich internal loop: bit mask reporting faulty channels (0x0001 = chan. 160, 0x0002 = chan. 161,..,0x8000 = chan. 175) cases MUNICH-DSP and MUNICH-FPGA loop mode set: value read on AbIC-10 cases MUNICH-DSP and MUNICH-FPGA loop failure: bit mask of faulty channels (160-175) 17 = case c: not used case a (first sysinfo): 1) In case of invalid RLC blocks: bit mask of failed channels (PDT) related to ABIC-11 2) In case of IRQ1 interrupt not working: alarm status of AbIC-11 3) In case of unsuccessful DSP load: low byte: values read on AbIC-11 (high byte of value) high byte: values read on AbIC-12 (low byte of value) 4) In case of NMI (last detected hardware condition): low byte = NMI Source watchdog or SERR# signal (bit 7 is set if a system board agent, that is PCI device or main memory, detects a system board error, bit 6 is set if an watchdog time out is asserted) high byte = PIIX4 PCI Status: bit 6 SERRS -> is set when PIIX4 asserts the SERR# signal. bit 5 MAS -> PIIX4 as a master, it generates a master-abort. bit 4 RTA -> received target-abort status bit 3 STA -> signaled target-abort status bit 2:1 DEVSEL# -> timing status (DEVT) 5) Otherwise: not used case a (second sysinfo): In case of too late download of RLC blocks: bit mask of failed channels (PDT) related to ABIC-11 In case of NMI (before processing last exception): first and second bytes of MUSYCC add info. Otherwise: not used case a (third sysinfo): In case of NMI: OS trap
A30808-X3247-K240-3-7619 891

Outputs OML:BSC

Base Station Controller

Otherwise: not used case b: used in the following cases (PPXU only): case Munich internal loop: bit mask reporting faulty channels (0x0001 = chan. 176, 0x0002 = chan. 177,..,0x8000 = chan. 191) cases MUNICH-DSP and MUNICH-FPGA loop mode set: value read on AbIC-11 cases MUNICH-DSP and MUNICH-FPGA loop failure: bit mask of faulty channels (176-191) 18 = case c: not used case a (first sysinfo): 1) In case of invalid RLC blocks: bit mask of failed channels (PDT) related to ABIC-12 2) In case of IRQ1 interrupt not working: alarm status of AbIC-12 3) In case of unsuccessful DSP load: low byte: values read on AbIC-12 (high byte of value) high byte: values read on AbIC-13 (low byte of value) 4) In case of NMI (last detected HW condition): low byte: SNAP configuration register high byte: PIC in service 5) Otherwise: not used case a (second sysinfo): In case of too late download of RLC blocks: bit mask of failed channels (PDT) related to ABIC-12 In case of NMI (before processing last exception): third and fourth bytes of MUSYCC add info. Otherwise: not used case a (third sysinfo): In case of NMI: OS trap Otherwise: not used case b: used in the following cases (PPXU only): case Munich internal loop: bit mask reporting faulty channels (0x0001 = chan. 192, 0x0002 = chan. 193,..,0x8000 = chan. 207) cases MUNICH-DSP and MUNICH-FPGA loop mode set: value read on AbIC-12 cases MUNICH-DSP and MUNICH-FPGA loop failure: bit mask of faulty channels (192-207) 19 = case c: not used case a (first sysinfo): 1) In case of invalid RLC blocks: bit mask of failed channels (PDT) related to ABIC-13 2) In case of IRQ1 interrupt not working: alarm status of AbIC-13 3) In case of unsuccessful DSP load: low byte: values read on AbIC-13 (high byte of value) high byte: values read on AbIC-14 (low byte of value) 4) NMI case (last detected HW condition): low byte = PIC in service high byte = interrupts and NMI register 5) Otherwise: not used case a (second sysinfo): In case of too late download of RLC blocks: bit mask of failed channels (PDT) related to ABIC-13 In case of NMI: low byte: identifies the PPxx functional part that asserts the caught exception (0 = unknown; 1 =
892 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

PPXX internal access; 2 = MUSYCC; 3 = ISA bridge; 4 = MUNICH bridge; 5 = DSP access; 6 = TDPC duam; 7 = MPCC duam) high byte: type of exception (3 = NMI exception; 0 = interrupt exception). Otherwise: not used case a (third sysinfo): In case of NMI: OS trap Otherwise: not used case b: used in the following cases (PPXU only): case Munich internal loop: bit mask reporting faulty channels (0x0001 = chan. 208, 0x0002 = chan. 209,..,0x8000 = chan. 223) cases MUNICH-DSP and MUNICH-FPGA loop mode set: value read on AbIC-13 cases MUNICH-DSP and MUNICH-FPGA loop failure: bit mask of faulty channels (208-223) 20 = case c: not used case a (first sysinfo): 1) In case of invalid RLC blocks: bit mask of failed channels (PDT) related to ABIC-14 2) In case of IRQ1 interrupt not working: alarm status of AbIC-14 3) In case of unsuccessful DSP load: low byte: values read on AbIC-14 (high byte of value) high byte: values read on AbIC-15 (low byte of value) NMI case (last detected HW condition): low byte = FPGA conflict report (PPXU -> transmission conflict among DSP and MUSYCC; PPXL -> conflict between MUSYCC ports) high byte = TDPC alarm status (first byte) 4) Otherwise: not used case a (second sysinfo): In case of too late download of RLC blocks: bit mask of failed channels (PDT) related to ABIC-14 Otherwise: not used case a (third sysinfo): In case of NMI: OS trap Otherwise: not used case b: used in the following cases (PPXU only): case Munich internal loop: bit mask reporting faulty channels (0x0001 = chan. 224, 0x0002 = chan. 225,..,0x8000 = chan. 239) cases MUNICH-DSP and MUNICH-FPGA loop mode set: value read on AbIC-14 cases MUNICH-DSP and MUNICH-FPGA loop failure: bit mask of faulty channels (224-239) 21 = case c: not used case a (first sysinfo): 1) In case of invalid RLC blocks: bit mask of failed channels (PDT) related to ABIC-15 2) In case of IRQ1 interrupt not working: alarm status of AbIC-15 3) In case of unsuccessful DSP load: low byte: values read on AbIC-15 (high byte of value) 4) NMI case (last detected HW condition): TDPC alarm status (second and third bytes) 5) Otherwise: not used case a (second sysinfo):
A30808-X3247-K240-3-7619 893

Outputs OML:BSC

Base Station Controller

In case of too late download of RLC blocks: bit mask of failed channels (PDT) related to ABIC-15 Otherwise: not used case a (third sysinfo): In case of NMI: OS trap Otherwise: not used case b: used in the following cases (PPXU only): case Munich internal loop: bit mask reporting faulty channels (0x0001 = chan. 240, 0x0002 = chan. 241,..,0x8000 = chan. 255) cases MUNICH-DSP and MUNICH-FPGA loop mode set: value read on AbIC-15 cases MUNICH-DSP and MUNICH-FPGA loop failure: bit mask of faulty channels (240-255) 22 = case c: not used case a (first sysinfo): In case of missing download of RLC blocks: bit mask of failed channels (PDT) related to ABIC-0 In case of NMI (last detected HW condition): low byte = fourth byte of TDPC alarm status; high byte (PPXU only) = first byte of DSP Hpi Reg Int (this register stores the component which has sent the interrupt to the MUNICH) Otherwise: not used case a (second sysinfo): In case of invalid AbIC alarm report: bit mask of failed channels (PDT) related to ABIC-0 Otherwise: not used case a (third sysinfo): In case of NMI: OS trap Otherwise: not used case b: not used 23 = case c: not used case a (first sysinfo): In case of missing download of RLC blocks: bit mask of failed channels (PDT) related to ABIC-1 In case of NMI (last detected HW condition: PPXU only): low byte = second byte of DSP Hpi Register (see above); high byte = DSP Hpi Comreg Register: the host processor can control the DSP resets (A_RS, B_RS, C_RS, D_RS), the HPI port resets (RESET) and the selection of the HPI port of each sub-core by writing the corresponding bits. Otherwise: not used case a (second sysinfo): In case of invalid AbIC alarm report: bit mask of failed channels (PDT) related to ABIC-1 Otherwise: not used case a (third sysinfo): In case of NMI: OS trap Otherwise: not used case b: not used

894

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

24 =

case c: not used case a (first sysinfo): in case of missing download of RLC blocks: bit mask of failed channels (PDT) related to ABIC-2 In case of NMI (last detected HW condition): low byte = second byte of DSP Hpi Comreg Register (see above); high byte = first byte of DSP Hpi Reg Cli; this register is used to clear the bits on the RegInt register. Otherwise: not used case a (second sysinfo): In case of invalid AbIC alarm report: bit mask of failed channels (PDT) related to ABIC-2 In case of NMI: ip where nmi occurred (first two bytes) Otherwise: not used case a (third sysinfo): In case of NMI: OS trap Otherwise: not used case b: not used

25 =

case c: not used case a (first sysinfo): in case of missing download of RLC blocks: bit mask of failed channels (PDT) related to ABIC-3 In case of NMI (last detected HW condition): low byte = second byte of DSP Hpi Reg Cli; high byte = first byte of MUNICH PCI command status (PPXU only). Otherwise: not used case a (second sysinfo): In case of invalid AbIC alarm report: bit mask of failed channels (PDT) related to ABIC-3 In case of NMI: ip where nmi occurred (third and fourth bytes) Otherwise: not used case a (third sysinfo): In case of NMI: OS trap Otherwise: not used case b: not used

26 =

case c: not used case a (first sysinfo): in case of missing download of RLC blocks: bit mask of failed channels (PDT) related to ABIC-4 In case of NMI (last detected HW condition): second/third bytes of MUNICH PCI command status (PPXU only) Otherwise: not used case a (second sysinfo): In case of invalid AbIC alarm report: bit mask of failed channels (PDT) related to ABIC-4 In case of NMI:

A30808-X3247-K240-3-7619

895

Outputs OML:BSC

Base Station Controller

OS trap Otherwise: not used case b: not used 27 = case c: not used case a (first sysinfo): in case of missing download of RLC blocks: bit mask of failed channels (PDT) related to ABIC-5 In case of NMI (last detected HW condition): low byte = fourth byte of MUNICH PCI command status; high byte = first byte of MUNICH additional information (PPXU only). Otherwise: not used case a (second sysinfo): In case of invalid AbIC alarm report: bit mask of failed channels (PDT) related to ABIC-5 In case of NMI: OS trap Otherwise: not used case b: not used 28 = case c: not used case a (first sysinfo): in case of missing download of RLC blocks: bit mask of failed channels (PDT) related to ABIC-6 in case of NMI (last detected HW condition): second/third bytes of MUNICH add info (PPXU only). Otherwise: not used case a (second sysinfo): In case of invalid AbIC alarm report: bit mask of failed channels (PDT) related to ABIC-6 In case of NMI: OS trap Otherwise: not used case b: not used 29 = case c: not used case a (first sysinfo): in case of missing download of RLC blocks: bit mask of failed channels (PDT) related to ABIC-7 in case of NMI (last detected HW condition): low byte = fourth byte of MUNICH add info (PPXU only); high byte = first byte of MUSYCC PCI command status. Otherwise: not used case a (second sysinfo): In case of invalid AbIC alarm report: bit mask of failed channels (PDT) related to ABIC-7 In case of NMI: OS trap Otherwise: not used case b: not used case c: not used
896 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

30 =

case a (first sysinfo): In case of missing download of RLC blocks: bit mask of failed channels (PDT) related to ABIC-8 In case of NMI (last detected HW condition): second and third bytes of MUSYCC PCI command status. Otherwise: not used case a (second sysinfo): In case of invalid AbIC alarm report: bit mask of failed channels (PDT) related to ABIC-8 In case of NMI: OS trap Otherwise: not used case b: not used

31 =

case c: not used case a (first sysinfo): In case of missing download of RLC blocks: bit mask of failed channels (PDT) related to ABIC-9 In case of NMI (last detected HW condition): low byte = fourth byte of MUSYCC PCI command status; high byte = first byte of MUSYCC add info. Otherwise: not used case a (second sysinfo): In case of invalid AbIC alarm report: bit mask of failed channels (PDT) related to ABIC-9 In case of NMI: OS trap Otherwise: not used case b: not used

32 =

case c: not used case a (first sysinfo): In case of missing download of RLC blocks: bit mask of failed channels (PDT) related to ABIC-10 In case of NMI (last detected HW condition): second/third bytes of MUSYCC add info. Otherwise: not used case a (second sysinfo): In case of invalid AbIC alarm report: bit mask of failed channels (PDT) related to ABIC-10 In case of NMI: OS trap Otherwise: not used case b: not used

case c: not used ##fine##

A30808-X3247-K240-3-7619

897

Outputs OML:BSC

Base Station Controller

SYSINFO_ID: 133
SYSTEM INFO REPORT: Originator:

O-LINK OVERLOAD DETECTED


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 10107 MBAAW sysinfo description : An O-Link overload is detected 1 = Not used 2 = Not used 3 = Not used 4 = Not used 5 = Not used 6 = Not used 7 = Not used 8 = Not used 9 = Not used 10 = Not used 11 = Not used 12 = Not used 13 = Not used 14 = Not used 15 = Not used 16 = Not used 17 = Not used 18 = Not used 19 = Not used 20 = Not used 21 = Not used 22 = Not used 23 = Not used 24 = Not used 25 = Not used 26 = Not used 27 = Not used 28 = Not used 29 = Not used 30 = Not used 31 = Not used 32 = Not used ##fine##

898

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

SYSINFO_ID: 134
SYSTEM INFO REPORT: Originator:

O-LINK OVERLOAD CEASED


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 10107 MBAAW sysinfo description : The O-Link overload is ceased 1 = Not used 2 = Not used 3 = Not used 4 = Not used 5 = Not used 6 = Not used 7 = Not used 8 = Not used 9 = Not used 10 = Not used 11 = Not used 12 = Not used 13 = Not used 14 = Not used 15 = Not used 16 = Not used 17 = Not used 18 = Not used 19 = Not used 20 = Not used 21 = Not used 22 = Not used 23 = Not used 24 = Not used 25 = Not used 26 = Not used 27 = Not used 28 = Not used 29 = Not used 30 = Not used 31 = Not used 32 = Not used ##fine##

A30808-X3247-K240-3-7619

899

Outputs OML:BSC

Base Station Controller

SYSINFO_ID: 135
SYSTEM INFO REPORT: Originator:

INVALID MESSAGE OF ABIS/ASUB INFO


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 812 TOSICIOIT, 813 TOSICIOOT sysinfo description : It is no possible to receive or send a message from /to ABIS ASUB interface (SAPI is equal to 0), because some field of the RTE++ or NM or L3 headers is wrong: it is no possibile to calculate the message destination or channel number, card and tei number. 1 = 0x01 INVALID SOURCE SYS 0x02 INVALID SAPI 0x03 INVALID MESSAGE TYPE 0x04 INVALID OBJECT CLASS 0x05 INVALID LAPD ADDRESS 0x06 INVALID NETWORK ELEMENT 2 = Current value of the variable source_sys 3 = Current value of the variable dest_sys 4 = Current value of the variable sapi_no 5 = Current value of the variable btsm_no /trau_no/bts_no/trxidx 6 = Current value of the variable card_no 7 = Current value of the variable timeslot_no_hc 8 = Current value of the variable tei_no 9 = Current value of the variable message_discriminator 10 = Current value of the variable placement_indicator 11 = Current value of the variable sequence_number 12 = Current value of the variable length_indicator 13 = Current value of the variable message_type 14 = Current value of the variable object_class 15 = Current value of the variable object_inst_0 16 = Current value of the variable object_inst_1 17 = Current value of the variable object_inst_2 18 = The error value of db_get_lapd_address or db_get_network_element else it is 0. 19 = 0x01 REGULAR_CAPACITY_CONF 0X02 HIGH_CAPACITY_CONF 20 = not used 21 = not used 22 = not used 23 = not used 24 = not used 25 = not used 26 = not used 27 = not used 28 = not used
900 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

29 = not used 30 = not used 31 = not used 32 = not used ##fine##

A30808-X3247-K240-3-7619

901

Outputs OML:BSC

Base Station Controller

SYSINFO_ID: 136
SYSTEM INFO REPORT: Originator:

Llp Link Up Info


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4802 DHLPDCEN sysinfo description : This notification has the meaning to inform the operator that the LLP link is available. There are two types of this system information report identified by the Additional Info number 2. This is the first type of system info notification in case the LLP link becomes available. 1 = source code line (developer oriented) 2 = 1 (developer oriented: type of system info) 3 = absolute number of the lapd in Providing Service state (developer oriented) 4 = lapd dh finite state machine current state (developer oriented) 5 = level 2 lapd protocol state (developer oriented) 6 = current lapd instability counter (developer oriented) 7 = current lapd instability period (developer oriented) 8 = llp link state in lapd database (developer oriented) 9 = state of the lpdlm Providing Service (developer oriented) 10 = llp lapd timer for the instability (developer oriented) 11 = llp lapd last system info sent (developer oriented) 12 = Not used. 13 = Not used. 14 = Not used. 15 = Not used. 16 = Not used. 17 = Not used. 18 = Not used. 19 = Not used. 20 = Not used. 21 = Not used. 22 = Not used. 23 = Not used. 24 = Not used. 25 = Not used. 26 = Not used. 27 = Not used. 28 = Not used. 29 = Not used. 30 = Not used. 31 = Not used. 32 = Not used. ##fine##

902

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Case of XXXX = 4802 DHLPDCEN sysinfo description : This notification has the meaning to inform the operator that the LLP link is available. There are two types of this system information report identified by the Additional Info number 2. This is the second type of system info notification in case the LLP link becomes available. 1 = source code line (developer oriented) 2 = 2 (developer oriented: type of system info) 3 = state of the lpdlm Providing Service (developer oriented) 4 = lapd timer for the instability (developer oriented) 5 = llp lapd last system info sent (developer oriented) 6 = Not used. 7 = Not used. 8 = Not used. 9 = Not used. 10 = Not used. 11 = Not used. 12 = Not used. 13 = Not used. 14 = Not used. 15 = Not used. 16 = Not used. 17 = Not used. 18 = Not used. 19 = Not used. 20 = Not used. 21 = Not used. 22 = Not used. 23 = Not used. 24 = Not used. 25 = Not used. 26 = Not used. 27 = Not used. 28 = Not used. 29 = Not used. 30 = Not used. 31 = Not used. 32 = Not used.

A30808-X3247-K240-3-7619

903

Outputs OML:BSC

Base Station Controller

SYSINFO_ID: 137
SYSTEM INFO REPORT: Originator:

Llp Link Down Info


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 4802 DHLPDCEN sysinfo description : This notification has the meaning to inform the operator that the LLP link is not available. There are two types of this system information report identified by the Additional Info number 2. This is the first type of system info notification in case the LLP link becomes not available. 1 = source code line (developer oriented) 2 = 1 (developer oriented: type of system info) 3 = absolute number of the lapd in Providing Service state (developer oriented) 4 = lapd dh finite state machine current state (developer oriented) 5 = level 2 lapd protocol state (developer oriented) 6 = current lapd instability counter (developer oriented) 7 = current lapd instability period (developer oriented) 8 = llp link state in lapd database (developer oriented) 9 = state of the lpdlm Providing Service (developer oriented) 10 = llp lapd timer for the instability (developer oriented) 11 = llp lapd last system info sent (developer oriented) 12 = Not used. 13 = Not used. 14 = Not used. 15 = Not used. 16 = Not used. 17 = Not used. 18 = Not used. 19 = Not used. 20 = Not used. 21 = Not used. 22 = Not used. 23 = Not used. 24 = Not used. 25 = Not used. 26 = Not used. 27 = Not used. 28 = Not used. 29 = Not used. 30 = Not used. 31 = Not used. 32 = Not used. ##fine##

904

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Case of XXXX = 4802 DHLPDCEN sysinfo description : This notification has the meaning to inform the operator that the LLP link is not available. There are two types of this system information report identified by the Additional Info number 2. This is the second type of system info notification in case the LLP link becomes not available. 1 = source code line (developer oriented) 2 = 2 (developer oriented: type of system info) 3 = state of the lpdlm Providing Service (developer oriented) 4 = lapd timer for the instability (developer oriented) 5 = llp lapd last system info sent (developer oriented) 6 = Not used. 7 = Not used. 8 = Not used. 9 = Not used. 10 = Not used. 11 = Not used. 12 = Not used. 13 = Not used. 14 = Not used. 15 = Not used. 16 = Not used. 17 = Not used. 18 = Not used. 19 = Not used. 20 = Not used. 21 = Not used. 22 = Not used. 23 = Not used. 24 = Not used. 25 = Not used. 26 = Not used. 27 = Not used. 28 = Not used. 29 = Not used. 30 = Not used. 31 = Not used. 32 = Not used.

A30808-X3247-K240-3-7619

905

Outputs OML:BSC

Base Station Controller

SYSINFO_ID: 140
SYSTEM INFO REPORT: Originator:

STANDARD LOGGING SUSPENDED


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 10107 MBAAW sysinfo description : The Standard Log temporarily stops writing new records when an overload is detected while the O-Link is down 1 = Not used 2 = Not used 3 = Not used 4 = Not used 5 = Not used 6 = Not used 7 = Not used 8 = Not used 9 = Not used 10 = Not used 11 = Not used 12 = Not used 13 = Not used 14 = Not used 15 = Not used 16 = Not used 17 = Not used 18 = Not used 19 = Not used 20 = Not used 21 = Not used 22 = Not used 23 = Not used 24 = Not used 25 = Not used 26 = Not used 27 = Not used 28 = Not used 29 = Not used 30 = Not used 31 = Not used 32 = Not used ##fine##

906

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

SYSINFO_ID: 141
SYSTEM INFO REPORT: Originator:

STANDARD LOGGING RESUMED


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 10107 MBAAW sysinfo description : The Standard Log resumes its activity when the overload has ceased 1 = Not used 2 = Not used 3 = Not used 4 = Not used 5 = Not used 6 = Not used 7 = Not used 8 = Not used 9 = Not used 10 = Not used 11 = Not used 12 = Not used 13 = Not used 14 = Not used 15 = Not used 16 = Not used 17 = Not used 18 = Not used 19 = Not used 20 = Not used 21 = Not used 22 = Not used 23 = Not used 24 = Not used 25 = Not used 26 = Not used 27 = Not used 28 = Not used 29 = Not used 30 = Not used 31 = Not used 32 = Not used ##fine##

A30808-X3247-K240-3-7619

907

Outputs OML:BSC

Base Station Controller

SYSINFO_ID: 142
SYSTEM INFO REPORT: Originator:

MIT REQUEST POSTPONED


<RUN TIME DETERMINATED> XXXX

Additional Info :
1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32

Legend:
Case of XXXX = 10106 MBAMA sysinfo description : The request to align the MIT objects correlated to an equipment is postponed 1 = an integer identifying the module where the System Info is sent out 2 = the line (Hex value) where the System Info is sent out 3 = most significant part of the equipment type 4 = less significant part of the equipment type 5 = most significant part of the equipment number 6 = less significant part of the equipment number 7 = Debug information 8 = Debug information 9 = Debug information 10 = Debug information 11 = Debug information 12 = Debug information 13 = Debug information 14 = Debug information 15 = Debug information 16 = Debug information 17 = Debug information 18 = Debug information 19 = Debug information 20 = Debug information 21 = Debug information 22 = Debug information 23 = Debug information 24 = Debug information 25 = Not used 26 = Not used 27 = Not used 28 = Not used 29 = Not used 30 = Not used 31 = Not used 32 = Not used ##fine##

908

A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

Annex G

BSC FER Proposed Repair Actions


1 2 3 4 5 6 7 8 NoAction (Standard value). RepairActionRequired (Standard value - not used). Replace the addressed card. Test the addressed card(s) and perform the proper action according to the Test Result. Possibly, check also its (their) insertion in the frame. Alarm with warning severity. Refer to the manual for the proposed action. Environmental alarm. The repair action is defined by the operating company. Wait for the end of the Automatic Diagnostic and then perform the proper action according to the Test Result. Check on both sides the parameters of the line connecting the BSC and the faced Network Entity. Then, if it is all right, replace the line interface cards with the correct FW/HW edition. Check on both sides the parameters of the line connecting the BSC and the faced Network Entity. Then, check the line interface card state including the FW/HW editions. If it is all right, test the line interface cards. Finally, check the PCM cables and the HW of the faced Network Element. Check the PCM cable connected to the LICD and, possibly, tune the related BER. Check the signal emitted by the faced Network Element. Then, check the devices on the path between the BSC and the Network Element (CrossConnect, ..). Correct the configuration attribute value(s) for the addressed card(s) or replace the Hardware with one compatible with the configuration. Insert the addressed card in the frame. Then, test it. If the addressed card is the StandBy one, test it. Check the related cables, connections and line quality. Lock the related equipment. Provide information on the state of the BSC card versions (LICD, PLLH, SN) and speech quality to the customer service. Wait for the PLLH warm up (about 15 minutes). Check on both sides the LAPD parameters (TEI, LAPD timeslot) and correct them, if necessary. Format the Flash EPROM of the concerned BSCI card. If there are no more SYNC (SYNE) Managed Objects available to be automatically chosen as a new synchronization source, create a new one. Check the insertion of the LICD in the frame, then test it. If the Test Report is good, replace the UBEX. Replace the LICD and, if after re-entering in service, the problem is already present, call the customer assistance (problem of PLLH, active SN, Rack or Flat cable connecting base and extended modules).
909

10 11 12 13 14 15 16 17 18 19 20 21 22 23

A30808-X3247-K240-3-7619

Outputs OML:BSC

Base Station Controller

24 25 26 27 28 29

If the BSC is synchronized to the MSC, it is a problem of bad external source. If the BSC is free running, it is a problem of bad PLLH signal. Then, tune the PLLH. Test the related MPCC and perform the proper action according to the Test Result. Check the TRAU Network Entity. Check the BTS HW. Check the barring information and the BTS HW. Check the TRX HW.

Specific Problems Index

001 COMMAND FULL INITIALIZATION REQUIRED............................................................................... 471 002 DATABASE BACKUP FAILED .............................................................................................................. 253 003 FUNCTION CALL UNSUCCESSFUL..................................................................................................... 254 004 FILE SYSTEM OPERATION FAILURE ................................................................................................. 144 005 CHECK ON FILE CONTENTS FAILED ................................................................................................. 410 006 INTERWORKING COMMAND TABLE ERROR................................................................................... 543 007 SOFTWARE NOT ALIGNED .................................................................................................................. 574 008 FILE ALREADY IN USE.......................................................................................................................... 547 009 FILE TRANSFER ABORTED BY NETWORK ELEMENT ................................................................... 473 010 FILE TRANSFER FAILED ON NETWORK ELEMENT........................................................................ 475 011 FILE TRANSFER REFUSED BY NETWORK ELEMENT .................................................................... 476 012 STATUS MANAGER DATABASE NOT ALIGNED.............................................................................. 477 013 TDPC DATABASE NOT CONSISTENT................................................................................................. 127 014 TASK ABORTED BY SYSTEM .............................................................................................................. 538 015 GENERIC SOFTWARE ERROR.............................................................................................................. 478 016 BTSM SOFTWARE VERSION NOT DEFINED..................................................................................... 388 017 TRAU SOFTWARE VERSION NOT DEFINED ..................................................................................... 389 018 STATUS MANAGER DEVICE HANDLER AUDIT MISMATCH ........................................................ 128 019 UNABLE TO RUN TEST ......................................................................................................................... 482 020 WRONG CONNECTION REQUEST....................................................................................................... 483 021 CONNECTION REQUEST REJECTED .................................................................................................. 484 022 VARIABLE OUT OF RANGE WARNING.............................................................................................. 324 023 INVALID POINTER WARNING ............................................................................................................. 187 024 INVALID POINTER FULL INITIALIZATION....................................................................................... 192 025 INPUT PARAMETER OUT OF RANGE WARNING............................................................................. 160 026 MESSAGE NOT INITIALIZED WARNING ........................................................................................... 238 027 DATABASE INCONSISTENCY WARNING.......................................................................................... 128 028 AP CIRCUIT POOL MISMATCH............................................................................................................ 140 029 SYSTEM CALL UNSUCCESSFUL WARNING ..................................................................................... 256 030 SYSTEM CALL UNSUCCESSFUL PRIME TASK INIT........................................................................ 293 031 SYSTEM CALL UNSUCCESSFUL FULL INIT ..................................................................................... 297 032 MESSAGE OUT OF SEQUENCE WARNING........................................................................................ 240 033 TIMEOUT EXPIRED WARNING............................................................................................................ 304 034 COMMAND REJECTED WARNING...................................................................................................... 298 035 MAILBOX NOT ALLOCATED ERROR ................................................................................................. 486 036 UNSUCCESSFUL RESPONSE FROM STATUS MANAGER ERROR ................................................. 488 037 SPARE TO PRIME INITIALIZATION .................................................................................................... 489 038 PRIME TO FULL INITIALIZATION ...................................................................................................... 490
910 A30808-X3247-K240-3-7619

Outputs OML:BSC

Base Station Controller

039 FULL INIT REQUESTED ........................................................................................................................ 449 040 UNEXPECTED MESSAGE RECEIVED ERROR ................................................................................... 194 041 INVALID SPECIFIC PROBLEM IN ERROR CALL............................................................................... 174 042 INVALID OBJECT IDENTIFIER IN ERROR CALL.............................................................................. 175 043 START THROTTLING ERROR .............................................................................................................. 406 045 MEMORY NOT AVAILABLE................................................................................................................. 450 046 MESSAGE DISCARDED ......................................................................................................................... 491 047 RECEIVED CORRUPTED MESSAGE.................................................................................................... 222 048 ERROR MESSAGES DISCARDED ......................................................................................................... 460 049 MEMORY OVERFLOW........................................................................................................................... 461 050 DYNAMIC MEMORY POOL OVERFLOW ........................................................................................... 463 051 DELETED CURRENT TASK................................................................................................................... 495 052 SYSTEM RESTART ................................................................................................................................. 497 053 INACCESSIBLE DUAM ERROR ............................................................................................................ 302 054 AP A-BIS TIMER FAULT ........................................................................................................................ 176 055 AP BTS IDENTIFIER FAULT ................................................................................................................. 389 056 AP CELL OVERFLOW............................................................................................................................. 176 057 AP CELL NOT CONFIGURED................................................................................................................ 390 058 AP CHANNEL NOT CONFIGURED....................................................................................................... 391 059 REMOTE LOWER BER THRESHOLD EXCEEDED............................................................................. 379 060 AP MEMORY MESSAGE FAULT .......................................................................................................... 464 061 AP NO CHANNEL PRESENT.................................................................................................................. 548 062 AP NO FREE CHANNELS....................................................................................................................... 549 063 AP NO FREE CONNECTIONS ................................................................................................................ 549 064 AP NO FREE INSTANCE ........................................................................................................................ 550 065 AP NO HANDOVER REFERENCE......................................................................................................... 551 066 NO CALL IN CELL WITHIN A PREDEFINED TIME FRAME ............................................................ 124 067 AP TRX NOT CONFIGURED.................................................................................................................. 391 068 AP CONNECTION FAILURE .................................................................................................................. 108 069 AP ERROR REPORT ................................................................................................................................ 497 070 NO CALL IN TRX WITHIN A PREDEFINED TIME FRAME .............................................................. 125 071 AP ERROR INDICATION........................................................................................................................ 498 072 AP AIR TIMER FAULT ........................................................................................................................... 392 073 AP CELL GLOBAL IDENTIFICATION NOT PRESENT ...................................................................... 392 074 AP CHANNEL OVERFLOW.................................................................................................................... 177 075 AP CELL IDENTIFICATION NOT PRESENT ....................................................................................... 393 076 AP CONNECTION NOT ACTIVE........................................................................................................... 499 077 AP CONNECTION OVERFLOW............................................................................................................. 178 078 AP CONNECTION STATUS FAULT...................................................................................................... 500 079 AP ID2MBIT OVERFLOW ...................................................................................................................... 179 080 AP INCONSISTENCY.............................................................................................................................. 500 081 AP LOCATION AREA CODE CELL IDENTIFICATION NOT PRESENT........................................... 394 082 AP LOCATION AREA CODE NOT PRESENT ...................................................................................... 394 083 AP LOCATION AREA IDENTIFICATION NOT PRESENT ................................................................. 395 084 AP MESSAGE LENGTH FAULT ............................................................................................................ 229 085 AP MANDATORY ELEMENT FAULT .................................................................................................. 229 086 AP MANDATORY ELEMENT OVERFLOW ......................................................................................... 230 087 AP MODE OVERFLOW........................................................................................................................... 179 088 AP MESSAGE TYPE FAULT .................................................................................................................. 231 089 AP NO ADJACENT CELL ....................................................................................................................... 395 090 AP NO CELL PRESENT........................................................................................................................... 396 091 AP NO MEMORY..................................................................................................................................... 464 092 AP NO RADIO CHANNEL ...................................................................................................................... 503 093 AP NO TERRESTRIAL CHANNEL ........................................................................................................ 396 094 AP O&M DISCRIMINATOR FAULT...................................................................................................... 231 095 AP OPTIONAL ELEMENT FAULT ........................................................................................................ 232 096 AP OPTIONAL ELEMENT OVERFLOW ............................................................................................... 232
2 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

097 AP PROTOCOL DISCRIMINATOR FAULT .......................................................................................... 233 098 AP SUBCHANNEL OVERFLOW............................................................................................................ 180 099 AP TRX OVERFLOW ..............................................................................................................................180 100 AP TERRESTRIAL TIME SLOT OVERFLOW ...................................................................................... 181 101 AP NOT UPDATED.................................................................................................................................. 504 102 UNAVAILABLE RADIO SIGNALLING CHANNELS THRESHOLD MINOR .................................... 551 103 AP HW CIRCUIT IDENTITY CODE NOT CONFIGURED................................................................... 397 104 AP HW CIRCUIT IDENTITY CODE OVERFLOW ............................................................................... 182 105 UNCOMPATIBLE BSC CONFIGURATION .......................................................................................... 141 106 SCCP INVALID MSU RECEIVED .......................................................................................................... 360 107 ROUTING FAILURE................................................................................................................................ 373 108 INVALID MESSAGE FROM ABIS/ASUB.............................................................................................. 353 109 INVALID MESSAGE TO ABIS/ASUB.................................................................................................... 354 110 UNEXPECTED LPDL ESTABLISHED................................................................................................... 398 111 AP CONFUSION....................................................................................................................................... 504 112 PCM UNAVAILABLE REMOTE PROBLEMS....................................................................................... 367 113 BTS NO CBCH AVAILABLE .................................................................................................................. 350 114 MEMT DUAM OVERFLOW ................................................................................................................... 466 115 MEMT SEMAPHORE LOCKED ............................................................................................................. 505 116 MEMT CARD FAILURE............................................................................................................................ 16 117 LICD PERMANENT ERROR..................................................................................................................... 17 118 UNAVAILABLE RADIO SIGNALLING CHANNELS THRESHOLD MAJOR.................................... 552 119 IXLT CARD NOT IN FRAME ................................................................................................................... 18 120 IXLT SOFTWARE LMT LINK ERROR .................................................................................................... 19 121 IXLT SOFTWARE OMC LINK ERROR ................................................................................................... 20 122 IXLT FIRMWARE NOT READY .............................................................................................................. 20 123 TEMPERATURE UNACCEPTABLE ALARM ....................................................................................... 545 124 HUMIDITY UNACCEPTABLE ALARM................................................................................................ 436 125 AIR CONDITIONING EQUIPMENT ALARM ....................................................................................... 334 126 FIRE DETECTED ALARM ...................................................................................................................... 434 127 ENCLOSURE DOOR OPEN ALARM ..................................................................................................... 429 128 SMOKE DETECTION ALARM ............................................................................................................... 344 129 INTRUSION DETECTION ALARM ....................................................................................................... 342 130 TRANSMISSION EQUIPMENT ALARM ............................................................................................... 340 131 CTR GENERIC MESSAGE ...................................................................................................................... 507 132 CTR OVERLOAD ..................................................................................................................................... 346 133 MAIN POWER SUPPLY ALARM ........................................................................................................... 338 134 OPERATOR DEFINED ALARM ............................................................................................................. 336 135 AP BTS WITHOUT ALL BBSIG44 CARDS ........................................................................................... 398 136 INVALID MESSAGE TO PSOS............................................................................................................... 508 137 INVALID SEND MESSAGE IN RTE ...................................................................................................... 508 138 INVALID RECEIVE MESSAGE IN RTE ................................................................................................ 509 139 SYNCHRONISM OF PLLH ERROR........................................................................................................ 117 140 SYNC LINK ERROR ................................................................................................................................ 118 141 PLLH VCXO OUT OF NORMAL RANGE ............................................................................................. 119 142 SYNCHRONISM FAILED MEASUREMENT ........................................................................................ 120 143 NTW PERMANENT FAILURE ................................................................................................................. 21 144 UBEX PERMANENT FAILURE................................................................................................................ 24 145 PLLH PERMANENT FAILURE................................................................................................................. 27 146 SN64 PERMANENT FAILURE ................................................................................................................. 29 147 INVALID MESSAGE TO RTE................................................................................................................. 409 148 PSE ERROR .............................................................................................................................................. 509 149 INVALID SEND MESSAGE .................................................................................................................... 510 150 INVALID STREAM OUTPUT ................................................................................................................. 511 151 LICD ACCESS PROBLEM......................................................................................................................... 31 152 SYNE WITHOUT SIGNAL ...................................................................................................................... 120 153 PLLH NOT STABLE .................................................................................................................................. 11
A30808-X3247-K240-3-7619 3

Outputs OML:BSC

Base Station Controller

154 INVALID CLOSE ..................................................................................................................................... 512 155 SN16 PERMANENT FAILURE ................................................................................................................. 32 156 UNAVAILABLE RADIO SIGNALLING CHANNELS THRESHOLD CRITICAL ............................... 554 157 INVALID TYPE OF SN............................................................................................................................ 399 158 TOO MANY UBEX INTERRUPT ............................................................................................................. 36 159 PLLH NOT READY DUE TO PWRD........................................................................................................ 12 160 INVALID TYPE OF PLLH ....................................................................................................................... 400 161 PERMANENT COMPARISON ALARM ON SN ...................................................................................... 37 162 INVALID TYPE OF LICD........................................................................................................................ 400 163 WRONG PCM PARITY FROM LICD ....................................................................................................... 38 164 UNAVAILABLE ABIS TCH THRESHOLD MINOR ............................................................................. 555 165 UNAVAILABLE ABIS TCH THRESHOLD MAJOR ............................................................................. 557 166 UNAVAILABLE ABIS TCH THRESHOLD CRITICAL ........................................................................ 558 167 BCCH OUTAGE ....................................................................................................................................... 351 168 INVALID MSU RECEIVED..................................................................................................................... 361 169 SS7 LINK ACTIVATION FAILURE ....................................................................................................... 375 170 ERROR IN PREPAIRING FILE ............................................................................................................... 431 171 DISK NOT FORMATTED.......................................................................................................................... 38 172 DISK NOT ALIGNED ................................................................................................................................ 14 174 LPDL LINK UNSTABLE ......................................................................................................................... 363 175 LPDL LINK TRANSITION ...................................................................................................................... 364 176 LPDL LINK AUDIT MISMATCH ........................................................................................................... 141 177 INVALID ASUB MESSAGE .................................................................................................................... 233 178 TRAU ALIGNMENT FAILED ................................................................................................................. 512 179 BTSM FAILED ALIGNMENT ................................................................................................................. 514 181 INVALID ABIS MESSAGE ..................................................................................................................... 234 182 OMAL DISCONNECTED ........................................................................................................................ 109 183 X25 DISCONNECTED ............................................................................................................................. 110 184 CBCL DISCONNECTED.......................................................................................................................... 111 185 CBCL DISCONNECTED FOR OVERLOAD .......................................................................................... 112 186 IXLT SOFTWARE BAD RESTART .......................................................................................................... 39 187 IXLT SOFTWARE BAD COMMAND....................................................................................................... 40 188 MSC OVERLOAD DETECTED............................................................................................................... 347 189 LOSS OF SIGNAL ...................................................................................................................................... 94 190 LOSS OF SIGNAL ON LINK A ................................................................................................................. 95 191 LOSS OF SIGNAL ON LINK B ................................................................................................................. 96 192 AIS ALARM................................................................................................................................................ 97 193 AIS ALARM ON LINK A........................................................................................................................... 97 194 AIS ALARM ON LINK B ........................................................................................................................... 98 195 LOSS OF FRAME ALIGNMENT............................................................................................................. 438 196 LOSS OF FRAME ALIGNMENT ON LINK A........................................................................................ 439 197 LOSS OF FRAME ALIGNMENT ON LINK B........................................................................................ 440 198 LOSS OF CRC ALIGNMENT .................................................................................................................. 441 199 LOSS OF CRC ALIGNMENT ON LINK A .............................................................................................441 200 LOSS OF CRC ALIGNMENT ON LINK B ............................................................................................. 442 201 HIGHER BER THRESHOLD EXCEEDED ............................................................................................. 380 202 HIGHER BER THRESHOLD EXCEEDED ON LINK A ........................................................................ 381 203 HIGHER BER THRESHOLD EXCEEDED ON LINK B ........................................................................ 381 204 REMOTE ALARM.................................................................................................................................... 368 205 REMOTE ALARM ON LINK A............................................................................................................... 369 206 REMOTE ALARM ON LINK B ............................................................................................................... 369 207 IXLT CARD CORRUPTED........................................................................................................................ 41 208 SLIP ALARM ON LINK A ....................................................................................................................... 443 209 SLIP ALARM ON LINK B ....................................................................................................................... 444 210 LOWER BER THRESHOLD EXCEEDED ON LINK A ......................................................................... 382 211 LOWER BER THRESHOLD EXCEEDED ON LINK B ......................................................................... 383 212 HARDWARE FAILURE DIAGNOSTIC REQUEST ................................................................................. 42
4 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

213 HARDWARE FAILURE ............................................................................................................................. 52 214 CARD RESERVED FOR TEST.................................................................................................................. 60 215 CARD DIAGNOSTIC FAILED .................................................................................................................. 61 216 FILE TOO LONG WARNING.................................................................................................................. 432 217 PERIPHERAL CARD FAILURE DIAGNOSTIC REQUIRED.................................................................. 64 218 PERIPHERAL CARD HARDWARE FAILURE ........................................................................................ 67 219 UNAVAILABLE SS7 LINKS THRESHOLD MINOR ............................................................................ 376 220 BAD SOFTWARE ON PERIPHERAL CARD ......................................................................................... 515 221 UNAVAILABLE SS7 LINKS THRESHOLD MAJOR ............................................................................ 376 222 AP TRACE ERROR NOTIFICATION ..................................................................................................... 519 223 AP TRACE TDPC OVERLOAD .............................................................................................................. 347 224 UNAVAILABLE SS7 LINKS THRESHOLD CRITICAL ....................................................................... 377 225 UNAVAILABLE AINT TCH THRESHOLD MINOR ............................................................................. 560 226 UNAVAILABLE AINT TCH THRESHOLD MAJOR............................................................................. 560 227 UNAVAILABLE AINT TCH THRESHOLD CRITICAL ........................................................................ 561 228 IXLT CARD RESET ................................................................................................................................. 576 229 BRING UP ACTIVE REQUESTED ......................................................................................................... 520 230 MPCC OUTAGE ....................................................................................................................................... 561 231 TDPC OUTAGE........................................................................................................................................ 562 232 DYNAMIC MEMORY POOL OVERFLOW UPPINIT ........................................................................... 467 233 MEMT OUTAGE ...................................................................................................................................... 563 234 DISK OUTAGE......................................................................................................................................... 565 235 IXLT OUTAGE ......................................................................................................................................... 565 236 NTW OUTAGE ......................................................................................................................................... 566 238 UNABLE TO INITIALIZE ....................................................................................................................... 541 240 REPORT INCOMPLETED ....................................................................................................................... 520 241 EPWR OUTAGE ....................................................................................................................................... 566 242 PPCC OUTAGE ........................................................................................................................................ 567 243 BTS OVERLOAD DETECTED................................................................................................................ 348 244 AP TRACE ERROR NOTIFICATION UNAVAILABILITY .................................................................. 567 245 AP TRACE ERROR NOTIFICATION INVALID PARAMETER........................................................... 235 246 AP TRACE ERROR NOTIFICATION ABNORMAL TERMINATION ................................................. 541 247 FUNCTIONALITY LOST......................................................................................................................... 568 248 PPXX DEVICE HANDLER INTER PROCESSOR COMMUNICATION SEMAPHORE LOCKED .... 523 249 BSC OVERLOAD DETECTED................................................................................................................ 349 250 IMSI TRACE GENERIC MESSAGE ....................................................................................................... 524 251 SYNE OUTAGE........................................................................................................................................ 571 252 SS7L FAILURE ......................................................................................................................................... 377 253 SS7S FAILURE ......................................................................................................................................... 571 254 ENVA REGISTERS MISMATCH.............................................................................................................. 70 255 FULL INITIALIZATION OCCURRED ................................................................................................... 524 256 BRING UP INITIALIZATION OCCURRED........................................................................................... 526 257 L1CTS INTERRUPTION............................................................................................................................ 99 258 OMAL OUTAGE ...................................................................................................................................... 572 259 CBCL OUTAGE........................................................................................................................................ 572 260 X25 OUTAGE ........................................................................................................................................... 573 262 INVALID MESSAGE TO PCUC.............................................................................................................. 236 263 INVALID MESSAGE FROM PCUC ........................................................................................................ 354 264 INVALID ACCESS TO DATA................................................................................................................. 411 265 INVALID READING MESSAGE............................................................................................................. 355 266 MPCC HOT LINK FAILED...................................................................................................................... 100 267 TDPC HOT LINK FAILED....................................................................................................................... 101 268 BSSGP INVALID MESSAGE .................................................................................................................. 357 269 LINK DOWN............................................................................................................................................. 113 270 CONFIGURATION MISMATCH ............................................................................................................ 401 271 NSVC CONNECTION FAILURE ............................................................................................................ 115 273 OVERFLOW OF COMMANDS TABLES ............................................................................................... 407
A30808-X3247-K240-3-7619 5

Outputs OML:BSC

Base Station Controller

274 PCU ALIGNMENT FAILURE ................................................................................................................. 526 275 AP BVC OVERFLOW .............................................................................................................................. 183 276 AP BVC NOT CONFIGURED ................................................................................................................. 402 277 AP PCU OVERFLOW............................................................................................................................... 184 278 AP PCU NOT CONFIGURED.................................................................................................................. 403 279 AP PDT OVERFLOW............................................................................................................................... 184 280 AP PDT NOT CONFIGURED .................................................................................................................. 403 281 AP PCU TIMER FAULT .......................................................................................................................... 185 282 NOTIFIED LOSS OF SIGNAL................................................................................................................. 102 283 NOTIFIED AIS ALARM........................................................................................................................... 103 284 NOTIFIED LOSS OF FRAME ALIGNMENT ......................................................................................... 445 285 NOTIFIED LOSS OF CRC ALIGNMENT ............................................................................................... 445 286 NOTIFIED REMOTE ALARM................................................................................................................. 370 287 NOTIFIED HIGHER BER THRESHOLD EXCEEDED.......................................................................... 384 288 NOTIFIED LOWER BER THRESHOLD EXCEEDED........................................................................... 384 289 NOTIFIED LOSS OF SIGNAL ON LINK A............................................................................................ 103 290 NOTIFIED LOSS OF SIGNAL ON LINK B ............................................................................................ 104 291 NOTIFIED AIS ALARM ON LINK A...................................................................................................... 105 292 NOTIFIED AIS ALARM ON LINK B...................................................................................................... 105 293 NOTIFIED LOSS OF FRAME ALIGNMENT ON LINK A .................................................................... 446 294 NOTIFIED LOSS OF FRAME ALIGNMENT ON LINK B .................................................................... 447 295 NOTIFIED LOSS OF CRC ALIGNMENT ON LINK A .......................................................................... 447 296 NOTIFIED LOSS OF CRC ALIGNMENT ON LINK B .......................................................................... 448 297 NOTIFIED REMOTE ALARM ON LINK A............................................................................................ 371 298 NOTIFIED REMOTE ALARM ON LINK B............................................................................................ 372 299 NOTIFIED HIGHER BER THRESHOLD EXCEEDED ON LINK A.....................................................385 300 NOTIFIED HIGHER BER THRESHOLD EXCEEDED ON LINK B ..................................................... 386 301 NOTIFIED LOWER BER THRESHOLD EXCEEDED ON LINK A...................................................... 386 302 NOTIFIED LOWER BER THRESHOLD EXCEEDED ON LINK B ...................................................... 387 303 NOTIFIED GBIC CONFIGURATION MISMATCH............................................................................... 527 304 INVALID MESSAGE LENGTH............................................................................................................... 413 305 ABIC INVALID MESSAGE ..................................................................................................................... 236 306 AP ROUTING AREA CODE NOT PRESENT......................................................................................... 404 307 NOTIFY PDT ALIGNMENT LOST......................................................................................................... 106 308 INVALID DESTINATION MAILBOX .................................................................................................... 420 309 AP NOFREE PDT ..................................................................................................................................... 528 310 NOTIFY GPRS PREHEMPTION ............................................................................................................. 529 311 DYNAMIC MEMORY POOL OVERFLOW LOWINIT ......................................................................... 468 312 MEMORY OVERFLOW LOWINIT......................................................................................................... 469 313 MEMORY OVERFLOW UPPINIT .......................................................................................................... 469 314 DELETED CURRENT TASK LOWINIT................................................................................................. 530 315 DELETED CURRENT TASK UPPINIT .................................................................................................. 530 319 INVALID STATUS WARNING............................................................................................................... 535 320 INTER PROCESSOR COMMUNICATION PROBLEM WITH TDPC .................................................... 71 321 FATAL HARDWARE ERROR DETECTED BY TDPC ........................................................................... 73 322 SDSM SM DATABASE NOT ALIGNED ................................................................................................ 531 323 SDSM DATABASE NOT ALIGNED....................................................................................................... 532 324 ANOTHER OPERATION IS IN PROGRESS .......................................................................................... 532 326 DOWNLOAD FAILED ............................................................................................................................. 533 327 FILE UNUSABLE ..................................................................................................................................... 533 328 PERIPHERAL CARD INTER PROCESSOR COMMUNICATION PROBLEM WITH TDPC ............... 75 329 PERIPHERAL CARD FATAL HARDWARE ERROR DETECTED BY TDPC....................................... 76 330 PERIPHERAL CARD DIAGNOSTIC FAILED ......................................................................................... 78 331 BTSM UNSTABLE ALIGNMENT .......................................................................................................... 365 332 WRONG PROCESSOR COPY ................................................................................................................. 534 333 MEMORY BUFFER CORRUPTED ......................................................................................................... 423 334 NTW RECOVERY REQUIRED ................................................................................................................. 79
6 A30808-X3247-K240-3-7619

Base Station Controller

Outputs OML:BSC

335 UBEX RECOVERY REQUIRED ............................................................................................................... 82 336 PLLH RECOVERY REQUIRED ................................................................................................................ 85 337 SN64 RECOVERY REQUIRED ................................................................................................................. 87 338 SN16 RECOVERY REQUIRED ................................................................................................................. 91 339 FILE MISSING.......................................................................................................................................... 535 340 BUFFER NOT FOUND............................................................................................................................. 537 341 DATABASE NOT COMPATIBLE WITH ESUSW ................................................................................. 142 342 SNAP PERMANENT FAILURE ................................................................................................................ 34 343 SNAP RECOVERY REQUIRED ................................................................................................................ 89 344 TRAU AMR BUT POOLING DISABLED............................................................................................... 143 345 INVALID DUAM INDEX......................................................................................................................... 427 346 INVALID MESSAGE FROM PPXL......................................................................................................... 358 348 EXTENDED RACK 48V COPY 1 FAILED............................................................................................. 123

A30808-X3247-K240-3-7619