Resort Admin Office Key Plans and Elevations
Resort Admin Office Key Plans and Elevations
ELEVATIONS
NOTES
D3 D3
V1 V1
W1
STRUCTURAL DWGS.
5. FOUNDATION PCC SHOULD NOT BE CAST UNLESS GIVEN BY THE
V1
WC
F
W
C
+450 STRUCTURAL DESIGNER.
D3
6. CONCRETE CUBE TEST SHOULD BE TAKEN FOR ALL CONC. WORK AS PER I.S.
NORMS AND THE RESULTS SHOULD BE SUBMITTED TO THE ARCHITECTS
ADMIN OFFICE
6000 x 5000
+150
RESERVATION ROOM
W1
OFFICE IMMEDIATELY.
W +450
F
C 6000
W x 5000
+450
F
C
+300
D2
D2
2000 2000
W1 W1
1. CHECK FRESHNESS AND QUALITY OF CEMENT AND STEEL BEFORE USE BY
+7350 PARAPET LEVEL RECEPTION AREA
F
W
C
+450
LAB TESTING.
W2 R= 150
T= 300
2. ANY CONC. USED ON SITE SHALL BE MIXED IN MECH. MIXER.
20
19 1
3. ANY STRUCTURAL MEMBER SHALL NOT BE CAST UNLESS SIZE,
18
17
2
13
12
7
8
4. AGGREGATE SHALL BE TESTED FOR QUALITY BEFORE USE BY LAB TEST.
D2
11 9
10
5. SUFFICIENT NO. OF SUPERVISORS SHOULD BE PRESENT ON SITE DURING
+1500
CONCRETING WORK TO ENSURE PROPER WATER CEMENT RATIO, MIXING,
W4 MAIN ENTRANCE
W4
PLACING AND COMPACTING OF CONC.
+5850 LINTEL LEVEL 6. FORMWORK SHOULD BE WATER TIGHT, STRONG ENOUGH TO TAKE ALL
1
2
+450
+300
DEAD, LIVE AND DYNAMIC LOADS. PROPRE BRACING SHOULD BE PROVIDED.
3
W1 W1
+150
7. SPECIAL CARE SHOULD BE TAKEN TO ENSURE THAT STRUCTURAL DETAILS
RELEVANT TO EARTHQUAKE RESISTANCE SHOULD BE GOT UNDERSTOOD
AND STRICTLY FOLLOWED.
GROUND FLOOR KEY PLAN
W5
SCALE 1:200 IMPORTANT NOTES FOR SAFETY ON SITE
+4350 SILL LEVEL 1. NO PERSON SHOULD ENTER SITE WITHOUT HELMET.
2. NECESSARY SAFETY GEAR SUCH AS HELMET, SAFETY BELT TO BE
PROVIDED TO THE WORKMEN.
3. NECESSARY BARRICADES, RAILINGS, WARNING SIGNS TO BE INSTALLED ON
SITE ESPECIALLY FOR OPEN PITS, LIFT SHAFTS, DUCTS, OPEN SLABS ETC.
+3450 FIRST FLOOR LEVEL 4. ISURANCE POLICY FOR WORKMEN TO BE PROVIDED FOR THE PROJECT,
COPY TO BE SUBMITTED TO THE PMC.
W4 5. ALL ELECTRICAL WIRING TO BE TAKEN THROUGH CONDUITS AND CARE
SHOULD BE TAKEN TO SEE THAT ELECTRICAL WIRES ARE NOT LEFT OPEN,
+2850 LINTEL LEVEL WATER DOES NOT COME IN CONTACT WITH WIRES OR MACHINERY, PROPER
D2
W2 W2
EARTHING IS PROVIDED.
W1 W1 CONFERENCE ROOM
6. FIRST AID KIT SHOULD BE KEPT IN SITE OFFICE AND BOARD EXPLAINING
5000 +3450
W X 6000
D2
SPECIFICATION
W1 W1
V1
PASSAGE
W1
PLINTH LEVEL +450 MM
CUTOUT
W2
R= 150
T= 300
GLASS DOOR
20
19 1
BRICK TILE EXTERNAL CLADDING
SOUTH SIDE ELEVATION W2
18
17
16
15
14
2
SCALE 1:50 13 7
12 8
11 9
10
W4
DOOR SCHEDULE
NO. TYPE SIZE DESCRIPTION
+9750 TOPMOST LEVEL 1 D1 2000 X 2100 DOUBLE PANEL DOOR
4 D2 1000 X 2100 SINGLE LEAF DOOR
2 D3 800 X 2100 TOILET CUBICLE DOOR
2 D4 1000 X 2100 TOILET CUBICLE DOOR
PROJECT TITLE:
YEAR : T. Y. B-ARCH
ROLL NO :
DIV : D