DESIGN OF FRICTION SLAB CRASH BARRIER

DATA VALUE UNITS Reference


Type of Fiber Used GLASS
Concrete Exposed To Soil And Water NO
Cube Commpressive Strength fck 40 N/mm2
Ultimate Strength Of Rebar ffu* 810 N/mm2
Modulus Of Elasticity Ef 45000 N/mm2
Width b 1000 mm
Depth C D 450 mm
Design Moment Mu 54.94 kN-m
Design Shear Vu 53.33 kN
Allowable Crack Width 0.7 mm
Maximum Concrete Strain εcu 0.0025 440.1R, Cl. 7.1.2
Radius at Bent/Dia of Bar rb/db 3 440.1R, Cl.7.3.1
Clear Cover 25 mm
Diameter Of Main Bar 12 mm
Spacing Between Bars 200 mm
Area of Reinforcement Provided Af,pro 565.2 mm2
Moment Capacity Of The Section φ*Mn 127.843 kN-m
28 2
Cylinder Strength Of Concrete f' c N/mm
Environment Reduction Factor CE 0.8 440.1R, Table 6.2
648 2
Design Strength Of Rebar ffu N/mm 440.1R, Eq. (6.2a)
β1 0.6
Effective Depth Of Member d 409 mm
Ef*εcu 112.5
ρfb 0.0033 440.1R, Eq. (7.2.1b)

Design for Flexure

Initial Assumption Tension Controlled


Strength Reduction Factor φ 0.90 440.1R, Eq. (7.2.3)

Depth Of Neutral Axis cb 70.52 mm 440.1R, Eq. (7.2.2h)

242.89 2
Area of Reinforcement Required Af,reqd mm 440.1R, Eq. (7.2.2g)

% Reinforcement Required ρf 0.0006 440.1R, Eq. (7.2.1a)

218.60 2
Area of Reinforcement Required Af,reqd mm
OK

Horizon Design Consultants


Check
% Reinforcement Provided ρf 0.0014 440.1R, Eq. (7.2.1a)
Tensile Strength At Ultimate Condition ff 648.00 440.1R, Eq. (6.2a)

Reinforcement Ratio ρf /ρ fb 0.42


Type of Faliure TENSION CONTROLLED
Strength Reduction Factor φ 0.90 440.1R, Eq. (7.2.3)

Tension Controlled
Depth Of Neutral Axis cb 70.52 mm 440.1R, Eq. (7.2.2h)

Moment Capacity Mn 142.05 kNm 440.1R, Eq. (7.2.2g)

Reduced Moment Capacity φMn 127.84 kNm


OK
Compression Controlled
565.20 2
Area of Reinforcement Provided Af,pro mm
% Reinforcement Provided ρf 0.0014 440.1R, Eq. (7.2.1a)
ρf /ρ fb 0.42
Stress in FRP Bar
f 461.09 N/mm2 440.1R, Eq. (7.2.2d)
OK

Moment Capacity Mn 105.16 kNm

Reduced Moment Capacity φMn 94.64 kNm


OK
Transverse Reinforement
Min Steel ρf 368.10 mm2
7 250 mm
2
Af,pro 153.9 mm
Design for Shear
Modulus of Elasticity of Concrete Ec 31622.78 N/mm2

Modular Ratio nf 1.42


ρfnf 0.002
k 0.061 440.1R, Eq. (7.3.2.2b)
Reduced Shear Capacity φVn 78.92 440.1R, Eq. (8.2b)
OK