Troubleshooting Methods
Defect type Critical point to check
1. Check glove beading size
2. Check glove length
Beading blister 3. Check FT before post-leach
4. Check MO temperature
5. Check pre-leach temperature
1. Check glove beading size
2. Check glove length
Poor beading
3. Check pre-leach level
4. Check pre-leach temperature
1. Check MO temperature
2. Check infrared burner inside MO
Open beading
3. Check FT before latex dip tank
4. Check coagulant dryer temperature
1. Check CN% today and previous days
2. Check FT before enter coagulant
Cuff pinhole
3. Check pH at CT2 and CT3 using pH meter
4. Check former condition
1. Check technician method during topup Starta foam into latex
2. Check frequency of adding Starta foam by technician
Thin spot (latex 3. Clear bubbles on latex surface after adding Starta foam
side)
4. Check FT before latex dip tank
5. Check latex TSC% and pH today and previous days
Data
Next action
Spec / SV Actual / PV
Readjust beading roller position
Readjust latex level (level plate)
Reduce gas pressure for MO
Reduce gas pressure for MO
Increase pre-leach temperature
Readjust beading roller position
Readjust latex level (level plate)
Increase pre-leach level
Increase pre-leach temperature
Reduce gas pressure for MO
Service burner and set to orange flame colour
Reduce gas pressure for coagulant dryer
Reduce gas pressure for coagulant dryer
Increase CN%
Reduce CT4 and CT5 temperature
Topup chemical to achieve target pH of CT2 and CT3
Online former cleaning
Ensure they use filter / mesh during adding starta foam
Reduce frequency from 8 to 12 hourly