You are on page 1of 36

Cebu Microelectronincs, Inc.

Lapu-Lapu City

OPTICAL DEVICE ASSEMBLY 2

Die Bonding Machine Troubshooting Guide


Troubles Encountered

Cause

Solutions/Corrective

1 Temperature cannot reach desired temperature value.

Damaged Temperature Controller

Check heater filament resistanc


Replace Temperature Controller

2 Actual Temperature display is blinking/error.

Open thermocouple sensor.

Replace thermocouple sensor.

Solutions/Corrective Actions
Check heater filament resistance; approximately >70 ohms.
Replace Temperature Controller.
Replace thermocouple sensor.

Cebu Microelectronincs, Inc.


Lapu-Lapu City

OPTICAL DEVICE ASSEMBLY 2

TOSOK Troubshooting Guide


Troubles Encountered

Cause

Solutions/Corrective

1 Dry Solder

Main temperature not reached.

Check and adjust main tempera


Note: Check the total bonding tim

2 Solder Overflow/PD Chip displacement

Main temperature is too high.

Check and adjust main tempera


Note: Check the total bonding tim

3 Clogged tool

Heated pellet was sucked by the capillary.

Reheat tool then press puff.


Replace tool if pellet sucked can

4 Stem not level

Stage not properly levelled

Adjust z level alignment until sta

5 Actual temperature value displayed is open.

Open thermocouple wire.

Replace thermocouple wire.

Solutions/Corrective Actions
Check and adjust main temperature setting.
Note: Check the total bonding time againg, the total bonding time is 36 2 seconds.
Check and adjust main temperature setting.
Note: Check the total bonding time againg, the total bonding time is 36 2 seconds.
Reheat tool then press puff.
Replace tool if pellet sucked cannot be removed.
Adjust z level alignment until stage is perpendicularly aligned to the tool.

Replace thermocouple wire.

Cebu Microelectronincs, Inc.


Lapu-Lapu City

OPTICAL DEVICE ASSEMBLY 2

Wire Bonding Machine Troubshooting Guide


Cause

Solutions/Corrective

1 Main Heater Jig Error

Troubles Encountered

Open thermocouple sensor

Replace thermocouple sensor.


Reconnect thermocouple senso

2 Actual temperature value swings up and down

Loose thermocouple contact.

Remove and properly connect th

3 Desired temperature cannot be reached

Open heater filament wire.

Properly connect heater filamen

Damaged filament.

Replace heater filament.

4 Electrode remove

Worn out tool


Bonding force is too high

Replace tool.
Adjust force adjuster inside the b

5 Big crimping

Worn out tool


Capillary positioning

Replace capillary
Rotate the capillary and adjust t

6 Protruded wire

Operator skill
Worn out tool

Train/refresh operator in proper


Replace capillary

7 Ball fault

Torch electrode and the wire during torch condition is


either very near or very far.

Adjust the the capillary height. U

Torch electrode surface is already dirty due to


continuous spark/burn made during process.

Polish the torch electrode surfac

8 No bonding on 2nd bond

Tool positioning

Rotate the capillary to adjust to

9 Clogged Capillary

The ball at the end of the wire melted at the tip of the
capillary after the torch activity.

Slowly unclog the capillary using

deformed capillary tool tip

change new capillary tool

10 tool mark

Solutions/Corrective Actions
Replace thermocouple sensor.
Reconnect thermocouple sensor if no spare thermocouple sensors.
Remove and properly connect the thermocouple sensor.
Properly connect heater filament wire.
Replace heater filament.
Replace tool.
Adjust force adjuster inside the bonding machine.
Replace capillary
Rotate the capillary and adjust the best crimping quality.
Train/refresh operator in proper wire bond handling.
Replace capillary
Adjust the the capillary height. Use the capillary height adjuster jig.

Polish the torch electrode surface then wipe with cotton buds. Polish the surface just enough to eliminate the dirt.

Rotate the capillary to adjust to the position where 2nd bonding is good. (Trial and Error)
Slowly unclog the capillary using the unplugging probes.

change new capillary tool

Cebu Microelectronincs, Inc.


Lapu-Lapu City

OPTICAL DEVICE ASSEMBLY 2

Vacuum Baking Machine Troubshooting Guide


Troubles Encountered

Cause

Solutions/Corrective

1 Turbo alarm error

Turbo power remote off thats why it will not run

Press REM/LOC then set to run

2 LCD touch screen display blurry & blinking

Damaged LCD touch screen

Replace LCD touch screen

Solutions/Corrective Actions
Press REM/LOC then set to run turbo power.
Replace LCD touch screen

Cebu Microelectronincs, Inc.


Lapu-Lapu City

OPTICAL DEVICE ASSEMBLY 2

Spot Welder Machine Troubshooting Guide


Troubles Encountered

Cause

Solutions/Corrective

1 jig mark

wornout tip block

replace new tip block

2 out of spec after weld

wornout tip block & oring

replace new tip block & oring

3 incomplete welding during pinch test

wornout tip block


unlevel whole dieset

replace new tip block


level the whole dieset

4 no LD beam appeared on the monitor

damaged pin socket inside LED guide

change pin socket

5 splashes

wornout tip block

replace new tip block

6 cap cannot reached to the stem surface

misaligned x & y axis alignment

change setting on x & y alignme

7 no light on camera

damaged halogen lamp

change halogen lamp

8 x & y micrometer cannot move anymore

damaged x & y micrometer

replaced x & y micrometer

9 error display on x & y micrometer

empty battery

replaced new battery

Solutions/Corrective Actions
replace new tip block
replace new tip block & oring
replace new tip block
level the whole dieset
change pin socket
replace new tip block
change setting on x & y alignment
change halogen lamp
replaced x & y micrometer
replaced new battery

Cebu Microelectronincs, Inc.


Lapu-Lapu City

OPTICAL DEVICE ASSEMBLY 2

Helium Bombing Machine Troubshooting Guide


Troubles Encountered
1 Cannot start bombing due to bombing pressure cannot
reached the limit of .6 MPA

Cause
Lack of helium inside the tank

Solutions/Corrective
Replace new helium tank.

Solutions/Corrective Actions
Replace new helium tank.

Cebu Microelectronincs, Inc.


Lapu-Lapu City

OPTICAL DEVICE ASSEMBLY 2

Fine Leak Tester Troubshooting Guide


Troubles Encountered

Cause

1 Error 04 & 05 display

NG BG filament 1

2 Sensitivity 04 / bad BG

Dirty analyzer tube,anti scatta,anti scatta parts & repeller

Solutions/Corrective Actions
Switch to filament 2 then performed auto calibration
Clean the anti scatta, repeller and other parts with scotch brite.
Note: Take note of parts alignment and positioning.

Cebu Microelectronincs, Inc.


Lapu-Lapu City

OPTICAL DEVICE ASSEMBLY 2

Gross Leak Tester Troubshooting Guide


Troubles Encountered
1 Water level error

Cause
Lack of flourinert water

Solutions/Corrective
Add flourinert water

Solutions/Corrective Actions
Add flourinert water

Cebu Microelectronincs, Inc.


Lapu-Lapu City

OPTICAL DEVICE ASSEMBLY 2

Laser Marking Troubshooting Guide


Troubles Encountered
1

Cause

Solutions/Corrective

Solutions/Corrective Actions

Cebu Microelectronincs, Inc.


Lapu-Lapu City

OPTICAL DEVICE ASSEMBLY 2

Temperature Cycling Troubshooting Guide


Troubles Encountered

Cause

Solutions/Corrective

Solutions/Corrective Actions

Cebu Microelectronincs, Inc.


Lapu-Lapu City

OPTICAL DEVICE ASSEMBLY 2

I-L Tester Troubshooting Guide


Troubles Encountered

Cause

Solutions/Corrective

Solutions/Corrective Actions

Cebu Microelectronincs, Inc.


Lapu-Lapu City

OPTICAL DEVICE ASSEMBLY 2

Id Tester Troubshooting Guide


Troubles Encountered

Cause

Solutions/Corrective

Solutions/Corrective Actions

Cebu Microelectronincs, Inc.


Lapu-Lapu City

OPTICAL DEVICE ASSEMBLY 2

Aging Equipment Troubshooting Guide


Troubles Encountered

Cause

Solutions/Corrective

1 No data on APC process

program bug

Restart APC process and Inform

2 Program hang up

undetermined [Program bug]

Restart the program and Inform

Solutions/Corrective Actions
Restart APC process and Inform OPNEXT.
Restart the program and Inform OPNEXT.

Cebu Microelectronincs, Inc.


Lapu-Lapu City

OPTICAL DEVICE ASSEMBLY 2

Digitam Microscope(Keyence)
Troubles Encountered

Troubshooting Guide

Cause

Solutions/Corrective

Solutions/Corrective Actions

Cebu Microelectronincs, Inc.


Lapu-Lapu City

OPTICAL DEVICE ASSEMBLY 2

YAG Welding Machine Troubshooting Guide


Troubles Encountered

Cause

Solutions/Corrective

1 yag alarm occur

lack of deionized water

add deionized water

2 no dsplay on drive current

open LD fixture connection

change LD fixture

3 gimbal jig cannot float

airvalve opening is small

enlarge opening of air valve

4 lightloss

unleveled gimbal jig

leveled gimbal jig

5 not enough power

unlevel gimbal jig


gimbal movement is not smooth.

level gimbal jig


ensure that gimbal can move fre

Solutions/Corrective Actions
add deionized water
change LD fixture
enlarge opening of air valve
leveled gimbal jig
level gimbal jig
ensure that gimbal can move freely during float.

Cebu Microelectronincs, Inc.


Lapu-Lapu City

OPTICAL DEVICE ASSEMBLY 2

Spot Welder(Stem Guide) Machine


Troubles Encountered

Troubshooting Guide

Cause

Solutions/Corrective

Solutions/Corrective Actions

Cebu Microelectronincs, Inc.


Lapu-Lapu City

OPTICAL DEVICE ASSEMBLY 2

UV Alignment Equipment Troubshooting Guide


Troubles Encountered

Cause

Solutions/Corrective

1 Low IL current

AQ2201 Frame Controller wrong setting


dirty surface on master fiber

change the wrong setting


clean or change new fiber

2 GBIP laser on error

program bug

reser the machine

3 Low RL

dirty fiber surface


dirty receptacle
Return Loss not calibrated properly.

clean or change new fiber


ensure that receptacle used is c
recalibrate return loss.

Solutions/Corrective Actions
change the wrong setting
clean or change new fiber
reser the machine
clean or change new fiber
ensure that receptacle used is clean
recalibrate return loss.

Cebu Microelectronincs, Inc.


Lapu-Lapu City

OPTICAL DEVICE ASSEMBLY 2

DCAC Tester Troubshooting Guide


Troubles Encountered
1 -d NG

Cause

Solutions/Corrective

flexboard is not properly aligned to the terminals of the


fixture.

properly align the terminals of th

dirty fiber

clean or change new fiber


Note: Recalibrate the DCAC tes

Solutions/Corrective Actions
properly align the terminals of the flexboard and the fixture

clean or change new fiber


Note: Recalibrate the DCAC test equipment if -d continues to occur.