Drafts - Side 140mm
Drafts - Side 140mm
10
[Link]/content/hilti/CP/XX/[Link]
Company: Page: 1
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Side 140mm Date: 1/27/2025
Fastening point:
Specifier's comments:
1 Input data
Anchor type and diameter: HST3-R M16 hef1
Return period (service life in years): 50
Item number: 2105876 HST3-R M16x135 35/15
Specification text: Hilti HST3 stud anchor with 80 mm
embedment, M16 hef1, Stainless steel,
installation per ETA 98/0001
Profile: no profile
Base material: 2
cracked concrete, C40/50, fc,cyl = 40.00 N/mm ; h =150.0 mm, User-defined partial material safety factor gc
= 1.500
Installation: Hammer drilled hole, Installation condition: Dry
Reinforcement: no reinforcement or reinforcement spacing >= 150 mm (any Ø) or >= 100 mm (Ø <= 10 mm)
no longitudinal edge reinforcement
Application also possible with HST4-R M16 under the selected boundary conditions.
More information in section Alternative fastening data of this report.
R
- The anchor calculation is based on a rigid anchor plate assumption.
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
1
Hilti PROFIS Engineering 3.1.10
[Link]/content/hilti/CP/XX/[Link]
Company: Page: 2
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Side 140mm Date: 1/27/2025
Fastening point:
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
2
Hilti PROFIS Engineering 3.1.10
[Link]/content/hilti/CP/XX/[Link]
Company: Page: 3
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Side 140mm Date: 1/27/2025
Fastening point:
1
Anchor reactions [kN]
Tension force: (+Tension, -Compression)
Anchor Tension force Shear force Shear force x Shear force y
1 16.287 1.014 -0.798 -0.625
2 15.468 1.153 0.968 -0.625 x
Tension
Compression
Max. concrete compressive strain: 0.45 [‰]
Max. concrete compressive stress: 13.52 [N/mm ]
2
Anchor forces are calculated based on the assumption of a rigid anchor plate.
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
3
Hilti PROFIS Engineering 3.1.10
[Link]/content/hilti/CP/XX/[Link]
Company: Page: 4
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Side 140mm Date: 1/27/2025
Fastening point:
N
NEd £ NRd,s = Rk,s EN 1992-4, Table 7.1
gMs
y c · NRk,p
NEd £ NRd,p = EN 1992-4, Table 7.1
gMp
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
4
Hilti PROFIS Engineering 3.1.10
[Link]/content/hilti/CP/XX/[Link]
Company: Page: 5
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Side 140mm Date: 1/27/2025
Fastening point:
N
NEd £ NRd,c = Rk,c EN 1992-4, Table 7.1
gMc
0 Ac,N
NRk,c = NRk,c · 0
· y s,N · y re,N · y ec1,N · y ec2,N · y M,N EN 1992-4, Eq. (7.1)
Ac,N
0 1,5
NRk,c = k1 · √fck · hef EN 1992-4, Eq. (7.2)
0
Ac,N = scr,N · scr,N EN 1992-4, Eq. (7.3)
c
y s,N = 0.7 + 0.3 · 1.00 EN 1992-4, Eq. (7.4)
ccr,N £
1
y ec1,N = £ 1.00 EN 1992-4, Eq. (7.6)
1+ ( 2 · eN,1
scr,N )
1
y ec2,N = £ 1.00 EN 1992-4, Eq. (7.6)
1+ ( 2 · eN,2
scr,N )
y M,N =1 EN 1992-4, Eq. (7.7)
2 0 2 2
Ac,N [mm ] Ac,N [mm ] ccr,N [mm] scr,N [mm] fc,cyl [N/mm ]
86,400 57,600 120.0 240.0 40.00
Group anchor ID
1, 2
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
5
Hilti PROFIS Engineering 3.1.10
[Link]/content/hilti/CP/XX/[Link]
Company: Page: 6
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Side 140mm Date: 1/27/2025
Fastening point:
V
VEd £ VRd,s = Rk,s EN 1992-4, Table 7.2
gMs
0
VRk,s = k7 · VRk,s EN 1992-4, Eq. (7.35)
0
VRk,s [kN] k7 VRk,s [kN] gMs VRd,s [kN] VEd [kN]
48.600 1.000 48.600 1.250 38.880 1.153
4.2 Steel failure (with lever arm)
V
VEd £ VRd,s,M = Rk,s,M EN 1992-4, Table 7.2
gMs
aM · MRk,s
VRk,s,M = EN 1992-4, Eq. 7.37
la
MRk,s
0
= MRk,s · (1 - NN )
Ed
Rd,s
EN 1992-4, Eq. 7.38
t
la = ec + + a3 EN 1992-4, Eq. 6.2
2
l [mm] aM
23.0 2.00
0 0
NEd / NRd,s 1 - NEd / NRd,s MRk,s [kNm] MRk,s = MRk,s (1 - NEd/ NRd,s) [kNm]
0.312 0.688 0.216 0.149
M M
VRk,s = aM * MRk,s / l [kN] gMs VRd,s [kN] VEd [kN]
12.922 1.250 10.338 1.153
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
6
Hilti PROFIS Engineering 3.1.10
[Link]/content/hilti/CP/XX/[Link]
Company: Page: 7
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Side 140mm Date: 1/27/2025
Fastening point:
V
VEd £ VRd,cp = Rk,cp EN 1992-4, Table 7.2
gMc,p
VRk,cp = k8 · NRk,c EN 1992-4, Eq. (7.39a)
0 A
NRk,c = NRk,c · c,N
0
· y s,N · y re,N · y ec1,N · y ec2,N · y M,N EN 1992-4, Eq. (7.1)
Ac,N
0 1,5
NRk,c = k1 · √fck · hef EN 1992-4, Eq. (7.2)
0
Ac,N = scr,N · scr,N EN 1992-4, Eq. (7.3)
c
y s,N = 0.7 + 0.3 · 1.00 EN 1992-4, Eq. (7.4)
ccr,N £
1
y ec1,N = £ 1.00 EN 1992-4, Eq. (7.6)
1+ ( 2 · eV,1
scr,N )
1
y ec2,N = £ 1.00 EN 1992-4, Eq. (7.6)
1+ ( 2 · eV,2
scr,N )
y M,N =1 EN 1992-4, Eq. (7.7)
2 0 2 2
Ac,N [mm ] Ac,N [mm ] ccr,N [mm] scr,N [mm] k8 fc,cyl [N/mm ]
43,200 57,600 120.0 240.0 3.410 40.00
Group anchor ID
2
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
7
Hilti PROFIS Engineering 3.1.10
[Link]/content/hilti/CP/XX/[Link]
Company: Page: 8
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Side 140mm Date: 1/27/2025
Fastening point:
V
VEd £ VRd,c = Rk,c EN 1992-4, Table 7.2
gMc
0 Ac,V
VRk,c = kT· y b,g · VRk,c · 0
· y s,V · y h,V · y a,V · y ec,V · y re,V EN 1992-4, Eq. (7.40)
Ac,V
1 1
y b,g = = Hilti Method for anchor design in grouted stand-off connections, Hilti, 2023
ab,g C tg
1+ 3
4
d
0 a b 1,5
VRk,c = k9 · dnom · lf · √fck · c1 EN 1992-4, Eq. (7.41)
0,5
a = 0.1 · () lf
c1
EN 1992-4, Eq. (7.42)
0,2
= 0.1 · (
c )
d nom
b EN 1992-4, Eq. (7.43)
1
0 2
Ac,V = 4.5 · c1 EN 1992-4, Eq. (7.44)
c2
y s,V = 0.7 + 0.3 · 1.00 EN 1992-4, Eq. (7.45)
1.5 · c1 £
0,5
y h,V = (1.5h· c ) 1
³ 1.00 EN 1992-4, Eq. (7.46)
1
y ec,V = £ 1.00 EN 1992-4, Eq. (7.47)
1+ ( 2 · eV
3 · c1 )
y a,V = √(cos a ) + (10.5 · sin a )
V
2
V
2 ³ 1.00 EN 1992-4, Eq. (7.48)
Group anchor ID
1, 2
When the input edge distance is set to "infinity", edge breakout verification is not performed in that direction
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
8
Hilti PROFIS Engineering 3.1.10
[Link]/content/hilti/CP/XX/[Link]
Company: Page: 9
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Side 140mm Date: 1/27/2025
Fastening point:
a a
bN + bV £ 1.0
Concrete failure
Comments: Tension displacements are valid with half of the required installation torque moment for uncracked concrete! Shear displacements are
valid without friction between the concrete and the anchor plate! The gap due to the drilled hole and clearance hole tolerances are not included in
this calculation!
The acceptable anchor displacements depend on the fastened construction and must be defined by the designer!
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
9
Hilti PROFIS Engineering 3.1.10
[Link]/content/hilti/CP/XX/[Link]
Company: Page: 10
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Side 140mm Date: 1/27/2025
Fastening point:
7 Warnings
• The anchor design methods in PROFIS Engineering require rigid anchor plates per current regulations (AS 5216:2021, ETAG 001/Annex C,
EOTA TR029 etc.). This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the
anchor plate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Engineering calculates
the minimum required anchor plate thickness with CBFEM to limit the stress of the anchor plate based on the assumptions explained above. The
proof if the rigid anchor plate assumption is valid is not carried out by PROFIS Engineering. Input data and results must be checked for
agreement with the existing conditions and for plausibility!
• The equations presented in this report are based on metric units. When inputs are displayed in imperial units, the user should be aware that the
equations remain in their metric format.
• Checking the transfer of loads into the base material is required in accordance with EN 1992-4, Annex A!
• The design is only valid if the clearance hole in the fixture is not larger than the value given in Table 6.1 of EN 1992-4! For larger diameters of the
clearance hole see section 6.2.2 of EN 1992-4!
• The accessory list in this report is for the information of the user only. In any case, the instructions for use provided with the product have to be
followed to ensure a proper installation.
• For the determination of the y re,v (concrete edge failure) the minimum concrete cover defined in the design settings is used as the concrete
cover of the edge reinforcement.
• Please note that this design utilizes user defined material safety factor values that differ from the default values recommended in EN1992-4.
Partial Safety factor value: gc = 1.500
• The characteristic bond resistances depend on the return period (service life in years): 50
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
10
Hilti PROFIS Engineering 3.1.10
[Link]/content/hilti/CP/XX/[Link]
Company: Page: 11
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Side 140mm Date: 1/27/2025
Fastening point:
8 Installation data
2 2
Anchor plate, steel: S 235; E = 210,000.00 N/mm ; fyk = 235.00 N/mm Anchor type and diameter: HST3-R M16 hef1
Profile: no profile Item number: 2105876 HST3-R M16x135 35/15
Hole diameter in the fixture: df = 18.0 mm Maximum installation torque: 110 Nm
Plate thickness (input): 10.0 mm Hole diameter in the base material: 16.0 mm
Recommended plate thickness: not calculated Hole depth in the base material: 113.0 mm
Drilling method: Hammer drilled Minimum thickness of the base material: 135.0 mm
Cleaning: No cleaning of the drilled hole is required
Hilti HST3 stud anchor with 80 mm embedment, M16 hef1, Stainless steel, installation per ETA 98/0001
35.0
y
85.0 85.0
30.0
1
90.0
120.0
x
90.0
2
30.0
120.0 50.0
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
11
Hilti PROFIS Engineering 3.1.10
[Link]/content/hilti/CP/XX/[Link]
Company: Page: 12
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Side 140mm Date: 1/27/2025
Fastening point:
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
12
Hilti PROFIS Engineering 3.1.10
[Link]/content/hilti/CP/XX/[Link]
Company: Page: 13
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Side 140mm Date: 1/27/2025
Fastening point:
10 Alternative fastening
10.1 Alternative fastening data
Profile: no profile
Base material: 2
cracked concrete, C40/50, fc,cyl = 40.00 N/mm ; h =150.0 mm, User-defined partial material safety factor gc
= 1.500
Installation: Hammer drilled hole, Installation condition: Dry
Reinforcement: no reinforcement or reinforcement spacing >= 150 mm (any Ø) or >= 100 mm (Ø <= 10 mm)
no longitudinal edge reinforcement
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
13
Hilti PROFIS Engineering 3.1.10
[Link]/content/hilti/CP/XX/[Link]
Company: Page: 14
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Side 140mm Date: 1/27/2025
Fastening point:
Hilti HST4 stud anchor with 80 mm embedment, M16, Stainless steel, installation per ETA-21/0878
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
14
Hilti PROFIS Engineering 3.1.10
[Link]/content/hilti/CP/XX/[Link]
Company: Page: 15
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Side 140mm Date: 1/27/2025
Fastening point:
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
15