CP

Class

Centrifugal pump Category Purchaser Qty Project P&I Diagram Tag No Description Database id Service Equipment Module Continuous duty, hours/year Operation in parallel Drive type Painting color Location Ambient Temperature Range, oC Fluid Fluid temperature, oC Fluid viscosity, kg/m/s Fluid vapor pressure, kPa Fluid pH Fluid density, kg/m3 Fluid composition Solids, ppm Free chlorine, ppm Chlorides, ppm Design flow rate, m3/h Rated flow rate, m3/h Differential head, m Suction pressure, Bara Discharge pressure, Barg Pump type Rotation as viewed from the coupling end (cw/ccw) Stage number Suction (single/double) Case split (radial/axial) Volute type Mounting Case pressure Maximum allowable Design Hydrostatic tests Mechanical seal type Seal lips (rotating/stationary) Seal manufacturer Seal model Manufacturer code Seal flush plan Impeleer type Impeller (open/closed) Impeller diameter Rated Maximum Minimum Impeller eye diameter Radial bearing type Thrust bearing type Radial/Thrust bearing life Lubrication method Working temperature Value * * * * * * * * * 6000 yes * RAL7001 * * * * * * * * * * * * * * * * * * * * * * * * * * * * * Carbon/Silicon carbide * * * * radial * * * * * * * * * * *

barcode Revision

GENERAL

OPERATION CONDITIONS

DESIGN

Visible lubricator Drive connection Coupling type Spacer length, mm Coupling manufacturer Coupling model Pump weight, kg Baseplate weight, kg Impeller weight, kg Suction Location Size ANSI rating Face CONNECTIONS Drainage connection, inch Discharge Location Size ANSI rating Face Gauge NPT connection on discharge, inch Proposal curve no Rpm NPSHA, m NPSHR(3%), m NPSHR(40000 hr), m Rated flow rate, m3/h Total head, m Efficiency, % HYDRAULIC Brake horsepower, kW PERFORMANCE BEP efficiency,% BEP head, m BEP flow rate, m3/h Shut-off head, m Shut-off head horsepower, kW Minimum flow rate (continuous/trip), m3/h Maximum flow rate (continuous/trip), m3/h Specific speed (metric) Suction specific speed (metric) Impeller Shaft MATERIALS Shaft sleeve Casing Casing wear rings Impeller wear rings Motor tag No Machine type Frame Voltage Frequency Synchronous rotation speed, rpm Speed, rpm Duty type Service factor Rated output, kW Nominal size, kW MOTOR Enclosure Insulation / Temp. rise Standards Altitude, max. Connection of stator winding

Yes * flexible with spacer 300 * * * * * * * * * * * * * * 1/4" * * * * * * * * * * * * * * * * * * * * * * * * * Squirrel Cage Rotor * 690V/3ph 50 Hz * * continuous 1.1 * * IP 55 * IEC 100m*

TESTS

DOCUMENT SUBMITTAL

SUPPLY SCOPE (for each pump)

STANDARDS

Direction of rotation (cw or ccw) Overload protection Space heater Weight of rotor, kg Total weight of motor, kg Moment of inertia, rotor / load Bearings type Bump NDT Hydrostatic NPSHR (3%) Performance String Submergence Bearing temperature Vibrations Overall dimensions Cross section Mechanical seal Allowable forces & moments Performance curves Certificate of compliance Material certificate (3.1B) Noise level certificate Alignment certificate Inspection programme plan Operation & maintenance manuals Pump Coupling Motor Spare parts Base plate Guard Mechanical seal Seal flushing system (if applicable) Instrumentation and control Vibration probe Bearing temperature element (RTD) Dimensions Shaft diameter and deflection Coupling guard Vibration test Pump shop test Motor test Stamping of name plates Material certificates

* * * * * * antifriction Non-witnessed no no no Non-witnessed no no no no yes yes yes yes yes yes yes -yes yes yes 1 1 1 1 1 1 1 ANSI B73.1 ANSI B73.1 ANSI B15.1
ISO 2372-B-III or API 610 Table 2-5

Hydraulic Institute level A IEC RSA CIF 81.95 A95 EN10204 3.1

All equipment shall be guaranteed against defective workmanship and materials for a period of two (2) years after the date of shipment from the Vendor All bearings shall have the guaranteed service life of over 40,000 hours (B10 life), minimum guaranteed life expectancy two [2] years Mechanical seals shall have a guarantee of two [2] years operation The electric motors shall have a guarantee of two [2] years operation

WARRANTY

The repair, replacement of the defective items and its supervision shall be at the Vendor expense wholly To minimize the revenue losses, the vendor shall submit the spare parts list to be stored at the site The performance curves of the pump shall be guaranteed by the Vendor for 20000 hours of operation. The expected rates of performance degradation with time (if any) shall be clearly stated

PURCHASE

Order status Order id Catalog id Client id Manufacturer Manufacturer Code Delivery time, weeks

RQ/PFQ/purchasing * * * * * *

MAINTENANCE

Date Total installed pieces Expected life, hours Scheduled maintenance, hours MTBSM, hours MTBF, hours MTTR, hours Revisions Description

* * *

Date

by/checked/approved autogenerated by pimansoft.com

NOTES:

* - to be filled by the Vendor MTBSM - mean time between scheduled maintenance MTBF - mean time before failure MTTR - mean time to restore