SELCO, established in 1960, specializes in high-quality generator control and alarm systems, primarily for marine and land-based applications. The company offers a wide range of products including electronic relays, alarm annunciators, and software, ensuring compliance with international standards and high reliability. SELCO's equipment is designed for easy installation and maintenance, providing customers with low total cost of ownership while supporting operations in over 60 countries.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
17 views20 pages

Shortform 20011

SELCO, established in 1960, specializes in high-quality generator control and alarm systems, primarily for marine and land-based applications. The company offers a wide range of products including electronic relays, alarm annunciators, and software, ensuring compliance with international standards and high reliability. SELCO's equipment is designed for easy installation and maintenance, providing customers with low total cost of ownership while supporting operations in over 60 countries.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

Short Form Catalogue

Generator Controls
and Alarm Systems
Company Profile Generator Control Generator Protection

Expect only the best


from SELCO
Since the origin in 1960, SELCO technology has provided the electrical
power generation market with high class equipment, living up to the major
international standards.

SELCO manufactures and supplies electronic relays and microprocessor


based equipment for control, monitoring and protection of medium sized
generators in parallel operation.

Primarily the products are used for generators on board ships and in com-
pact land-based power stations where operation in parallel with the grid
(utility) may also be a requirement.

SELCO also manufactures a wide range of alarm annunciators, indicator


panels and software for use in a variety of marine and land-based applications.
The process industry is one type of land-based application. All products
undergo thorough test and inspection procedures to ensure high reliability
and continuous operation in the field.

Since its establishment as an independent company in 1984, SELCO has


continuously expanded its activities within the generator control and alarm
annunciator markets. SELCO products are marketed and sold in more than 60
countries worldwide. SELCO offers a comprehensive range of services includ-
ing technical support, applications support and spare part services.

SELCO staff and its partners worldwide take pride in exceeding their custo-
mers’ expectations in their quality and excellent service.
Therefore, you should expect only the best from us!

The SELCO equipment has been thoroughly tested by


certified laboratories with regard to high vibration levels,
heat, cold, humidity, salt mist, EMC emission and immunity
as well as other parameters.

SELCO products are in accordance with all significant


international standards and have been approved and
certified by the major marine classification societies.
! „Even when you represent a small local
distributor, you feel important. Your problem
instantly becomes a challenge for the
whole SELCO team, and is never left
unanswered.“
Lubomir Wyrzykowski, Commercial Director,
Comel, Poland

2
Product Overview Generator Monitoring Alarm & Indication

SELCO’s product philosophy is to offer easy-to-install, serviceable and


reliable modular system components for mounting on switchboards and
control consoles. Systems based on such components provide high flexi-
bility, easy troubleshooting and require very little maintenance and service,
which give our customers a low Total Cost of Ownership (TCO).

SELCO generator controls cover all specific functions for generator sets in
parallel runnning. The components are ideal when converting a convention-
ally manned engine room to unmanned operation.
SELCO M8100 Synchroscope

Generator Control, Protection & Alarm & Indication


Monitoring - Analog alarm annunciation
- Generator protection: - Digital alarm annunciation
Short circuit, overcurrent, reverse - Alarm indication
power, excitation loss, engine protection. - Alarm and event logging
- Generator controls:
Synchronizing, frequency control,
active and reactive load sharing,
load control, power management,
engine control.
- Generator monitoring:
Voltage, frequency, power, insulation. SELCO T4800 Load Sharer

INSULATION BLACKOUT LOAD DEPENDING MASTER TIME POWER FREQUENCY VOLTAGE POWER FREQUENCY
MONITORING MONITORING START & STOP CONTROL REFERENCE MONITORING MONITORING MONITORING DEVIATION

ALARM ALARM ALARM ALARM


INDICATION INDICATION INDICATION INDICATION

REVERSE POWER REVERSE POWER REVERSE POWER REVERSE POWER


EXCITATION LOSS EXCITATION LOSS EXCITATION LOSS EXCITATION LOSS

OVERCURRENT OVERCURRENT OVERCURRENT OVERCURRENT

SHORT CIRCUIT SHORT CIRCUIT SHORT CIRCUIT SHORT CIRCUIT

TACHO SYNCHRONIZING TACHO SYNCHRONIZING TACHO SYNCHRONIZING SYNCHRONIZING

ENGINE ENGINE ENGINE


LOAD SHARING LOAD SHARING LOAD SHARING
CONTROLLER CONTROLLER CONTROLLER

VAr LOAD VAr LOAD VAr LOAD VAr LOAD


SHARING SHARING SHARING SHARING

MOTOR MOTOR MOTOR MOTOR


GOVERNOR GOVERNOR GOVERNOR
POTENTIOMETER POTENTIOMETER POTENTIOMETER POTENTIOMETER

AVR AVR AVR AVR

Typical equipment applied for three diesel generators and one shaft generator

3
Company Profile Generator Control Generator Protection

Synchronizing and
Load/Power Control
The SELCO T-Line
The SELCO T-Line units are for DIN rail mounting or normal screw mounting
in switchboards. Since the units are working on identical principles and have
similar design and adjustment schemes, they are easily installed or replaced.
All units are available in a number of versions varying in supply voltage and
other functions. Customer specific requirements can therefore often be met.

The T-Line units include Auto Synchronizers and Load Sharers. The Auto
Synchronizers perform automatic synchronization of incoming generators in a
minimum of time. The Load Sharers provide automatic load sharing and
system frequency control for generators running in parallel.

Two types of Auto Synchronizers and Load Sharers are available: One type for
synchronizing and load sharing on generators with conventional mechanical
governors (and electronic speed controllers via an intermediate motorized
potentiometer). The other type of Auto Synchronizers and Load Sharers is for
connection directly to all types of electronic speed controllers. For synchroniz-
ing SELCO also supplies a Synchroscope for illuminated indication of the
phase difference.

Also available is a VAr Load Sharer for automatic load sharing of the reactive
power or for power factor control on generators running in parallel with the
grid (utility).

Cogeneration Application

Grid
T4500

M8100

Busbar
T4500 B9300 T4500

T4800 T4800

G G

! „Competence creates great products.


Synchronizing Parallel Running Generators to the Grid
Competence and experience as demon-
strated by SELCO – create great and long
lasting products that accompany PT. Wijaya
Setianugraha Selindo year after year.“
Mr. Victor Wijaya, Managing Director,
PT. Wijaya Setianugraha Selindo, Indonesia

4
Product Overview Generator Monitoring Alarm & Indication

To T4400
T4000 Auto Synchronizer T4400 Load Sharer COM FREQ. IN

BUS Sync.
on
The T4000 performs automatic synchro- The T4400 is a load sharer for generators L1
nizing of an incoming generator with with electronic speed controllers. Basical- L2
L3
GEN.
electronic speed controllers in a mini- ly it performs the same task as the T4300 C/B
mum of time, by controlling the genera- Load Sharer. However, the T4400 also
tor speed and the phase between the includes a built-in frequency control and
generator and the busbar. an integration function. These two addi-
tional features provide a very high over-
The unit has fixed and variable output all stability and compensate for any drift
for adaptation to a wide range of elec- within the engine speed controller.
tronic speed controllers.
A soft load/unload function is also pro-
vided. When activated, the T4400 will

or unload
Soft load
Next
T4300 Load Sharer slowly increase or decrease speed to L1
Sync.T4000 T4400

transfer load to or from the generator. L2


GEN. GOV.
L3
A built-in relay can automatically trip
the circuit breaker when unload is com- BUS C/B

pleted.
T4000/4400 Gen-Set Application
The T4400 has a built-in reverse power
protection with selectable limit and time
The T4300 provides automatic iso- delay. One load sharing unit T4400 is
chronous load sharing for parallel run- required for each diesel generator in
ning generators in connection with a parallel operation. The load sharers are
wide range of electronic speed control- interconnected with a 2-wire cable.
lers. The load on each generator is com-
pared with the load of the other genera- When applied with the B9300 Power
tors and corrected until balance is ob- Reference Unit, one or several genera-
tained. An unloading facility is available tors can be operated in parallel with the
and when used, the load on the genera- grid.
tor is reduced and maintained on a low
value.

Optional functions such as unload trip


and reverse power trip are available.

When applied with the B9300 Power


Reference Unit, one or several genera-
tors can be operated in parallel with the
grid.

5
Company Profile Generator Control Generator Protection

Synchronizing and
Load/Power Control ... continued

T4500 Auto Synchronizer The unit also has reverse power protec-
tion. One load sharing unit T4800 is re-
quired for each diesel generator in paral-
lel operation. The load sharers are inter-
connected with a 2-wire cable.

When applied with the B9300 Power


Reference Unit, one or several genera-
The T4500 performs automatic synchro- tors can be operated in parallel with the
nization of an incoming generator in a grid.
minimum of time by controlling the fre-
quency via the electric servomotor on a
speed governor or via the E7800 Motor-
ized Potentiometer.

Among the features is an output signal


which can be used to control the T4800
Load Sharer e.g. to transfer a load from BUS
one or several diesel generators operat- L1
Sync. on

ing in parallel with the grid, or if on L2 GEN.


L3
board a ship, to a shaft generator.
C/B
The frequency will be aligned by the
synchronizer through the load sharers.
The unit has voltage matching output
with adjustable voltage window.

T4800 Load Sharer


Next
T4800
L1 Unload
L2
GEN.
L3

BUS

T4500/T4800 Gen-Set Application

The T4800 provides automatic load shar-


ing and system frequency control of
generators running in parallel. The load
on each generator is compared with the
load of the other generators and adjust-
ed via the electric servomotor on the
speed governor or a motorized poten-
tiometer until balance is obtained.

An unloading function is built into the


unit to facilitate a smooth transfer of the
load from a generator before being taken
! “The nature of Aggreko’s business out of service, by an automatic tripping
demands a high level of performance signal to the breaker.
from their supply chain. SELCO exceeds
that requirement.”
Frazer McNeill, Senior Buyer,
AGGREKO LTD, Dumbarton, Scotland

6
Product Overview Generator Monitoring Alarm & Indication

T4900 VAr Load Sharer E7800 Motorized Potentiometer B9300 Power Reference Unit

The T4900 provides automatic VAr load


sharing and system voltage control for The E7800 is intended as an intermedi- The B9300 is applied in connection with
parallel running generators. ate unit between the electronic speed SELCO Load Sharers T4300, T4400 and
controller and the SELCO automatic T4800, when running in parallel with
The VAr load and voltage are measured synchronizers or load sharers. For voltage the grid (utility).
on each generator, compared with the regulation it can be applied with the
other generators and corrected via the T4900 VAr Load Sharer. The unit determines the power to be
E7800 Motorized Potentiometer, until supplied from the generators to the grid,
balance is obtained. The T4900 VAr Load The E7800 Motorized Potentiometer can adjustable 0-100%.
Sharer can also be used for power factor also be used as an individual stand- Flush mounted unit with standard
(Cos φ) control on a generator in parallel alone unit for many industrial applica- measurements of 96 x 96 x 75mm.
operation with the grid. One unit is re- tions.
quired for each generator.
Available for AC or DC supply with the B9500 Master Time Controller
DC versions being equipped with a step-
T5000 Paralleling Relay per motor for adjustable speed.
Flush mounted unit with standard
measurements of 96 x 96 x 75mm.

M8100 Synchroscope

The B9500 is used together with the


The T5000 will, when synchronizing a T4800 Load Sharer and ensures that
generator to a busbar, give or enable a electric clocks, working on the system
closing signal to the generator circuit frequency, are precise. One B9500
breaker when voltage difference, phase Master Time Controller controls all
difference and frequency difference are generators operating in parallel.
within safe limits, thus preventing dam- Flush mounted unit with standard
age or disturbance to the power plant. The M8100 provides illuminated indica- measurements of 96 x 96 x 83mm.
The relay can be used as a synchroniz- tion of the actual phase difference be-
ing aid or as a check synchronizer. tween generator voltage and busbar
voltage. If the vector and the light spot
turn clockwise, the generator frequency
is too high and must be reduced. The
light spot turning anti clockwise indi-
cates a lower generator frequency and
consequently it must be increased.

When obtaining phase accordance, the


two green LEDs at 12 o’clock will indi-
cate and the generator circuit breaker
can be closed.
Flush mounted unit with standard
measurements of 96 x 96 x 80mm.

7
Company Profile Generator Control Generator Protection

Protective Relays and


Systems
The T-Line units include a complete range of relays for protection of genera-
tors. The trip levels and the delays before trip are easily adjustable using dials
placed under the removable front cover.

SELCO offers relays for protection of overload, reverse power, excitation


loss, overcurrent, short circuit and earth fault. Also available is a frequency
deviation relay for protecting generators operating in parallel to the grid
(utility) against interruptions of the grid.

Complete Protection of Generators

P (kW)

T2700 T2500 Overcurrent


Overload Relay and Short Circuit Relay
I x Cos φ

φ
I

I x Sin φ Q (kVAr)

T2100 Excitation T2000 Reverse


Loss Relay Generator’s Permitted Power Relay
Area of Operation

This figure illustrates the complete protection of a generator. The green area illustrates the
permitted area of operation for a generator. This information is normally supplied by the
generator manufacturer.

The vertical axis represents the active power, and the horizontal axis represents the reactive
power. The active power is represented by I x Cos φ. The T2700 Power Relay measures I x Cos φ,
and when it becomes too high, the relay will trip, indicated by the upper horizontal red line.

The Reverse Power relay measures -I x Cos φ, representing the active power in the negative
direction, and it will trip for reverse power. The T2100 Excitation Loss Relay measures -I x Sin φ,
representing the reactive power in negative direction, and it will trip when exceeding the level
represented by the red vertical line.
! „We selected SELCO products for their
compact design, high level features and long-
The T2500 Overcurrent and Short Circuit Relay measures the magnitude of the current and
term reliability. We have been delighted with
thus protects against current levels outside the area of the red circle.
their performance in our demanding
applications.”
Paul B. Luen, Director,
Martek Marine Ltd, United Kingdom

8
Product Overview Generator Monitoring Alarm & Indication

T2000 Reverse Power Relay T2200 3 Phase Overcurrent Relay T2700 Power Relay

The T2000 will, during parallel opera- The T2200 has a broad application, The T2700 is intended for detection of
tion, prevent the generator from running where all 3 phases or any single phase power level for protection, control and
as a motor, thus protecting the prime current detection will function as protec- monitoring purposes. The relay detects
mover e.g. a diesel engine and unload- tion, control or monitoring. the magnitude of the power and, when
ing the remaining generators by trip- The relay detects the highest of the 3 exceeding the preset value, an output
ping the generator breaker. input currents and, when exceeding the relay will be activated after a preset time
preset value, an output relay will be delay.
activated after a preset time delay.
T2100 Excitation Loss Relay
T2800 Overcurrent
T2300 3 Phase Short Circuit Relay or Earth Fault Relay

The T2100 protects against partial or


complete excitation loss on the synchro-
nous generator. If a generator under The T2300 is a relay intended for protec- The T2800 has a broad application as an
parallel operation has a low excitation, a tion of generators, power transmissions earth fault or a single phase overcurrent
high inductive current is running into and consumer supply against damage detection relay. It has a wide setting range
the generator. caused from short circuit by tripping the for protection, control or monitoring.
This current is detected and the faulty circuit breaker. The relay detects the magnitude of the
generator breaker is tripped, thus avoid- The relay detects the highest of the 3 current and, when exceeding the preset
ing overload on the other generators input currents and, when exceeding the value, an output relay will be activated
with a possible blackout of the system. preset value, an output relay will be after a preset time delay.
activated instantly (100 msec.) or after a
preset time delay.
T2400 3 Phase Dual T3500 Frequency Deviation Relay
Overcurrent Relay
T2500 3 Phase Overcurrent
and Short Circuit Relay

The T3500 will continuously monitor


The T2400 consists of 2 combined over- any deviation in frequency in a grid
current relays, intended for protection or where generators are operating in paral-
monitoring of generators, power trans- The T2500 is a relay intended for protec- lel. With the grid connected, the system
missions and consumer supply. tion of generators, power transmissions frequency is very stable, but if the grid is
A typical application for protection of a and consumer supply against thermal lost, subsequent frequency deviation
generator is for one of the overcurrent damage and faults caused by high cur- will be detected to trip the designated
functions to trip the generator breaker rents, with consequent tripping of the system breaker in order to protect the
and the other overcurrent function to trip system breaker. generator.
a nonessential service. Both overcurrent The relay detects the highest of the 3
functions could be used to trip 2 levels input currents and, when exceeding the
of nonessential loads. preset values, the output relay will be
The relay detects the highest of the 3 activated after preset time delays.
input currents and, when exceeding the
preset values, the output relays will be
activated after preset time delays.

9
Company Profile Generator Control Generator Protection

ls
ne
an
r
ch
tte
ter

tor
ller

10
me

mi
n it

tec
tro

s
6 W iator,
o

ran
eU

De
nt i

er
er
n

yT
o

oll
nc

it
ote

o
oll

c
C

e
el

Un

yC
un

ntr
g

a
r

nt r
ere

an
me

lta
ge
dP

n
wn

Co
rP

nc
Co

An
0 M r Ref

Vo
0 M er Ti
ize

Lo

rge
ato

do

00
ine
m
ine

ho
r
nt
e

oto

l
t

me
dic

lar

na
T1
hu

ng
ow

ac
ng
ve
a

0A

0A
0T

0P
0S
n

0E

0E
0E

0E
0P

0I

60
50

00

50

00

10

00
30

50

00
30

50

80

M0

M0

M1

M1

M2

M2

M4
M3
H0

H1

H2
B9

B9

E7
Alarm annunciation (analog) X
Alarm annunciation (digital) X X X X X X X
Alarm indication X X X X X X X X
Alarm logging X
Alarm repeating control X
Black out clearing
Check synchronizing / synchronizing aid
Constant power control X X
Earth fault protection
Engine control X X X
Engine shutdown X X X X
Excitation loss protection
Frequency control
Frequency deviation (delta time / delta freq.) protection
Grid control X X
Insulation monitoring
Load depending start / stop
Load sharing, DC control signal for electr. speed controllers
Load sharing, pulse outputs for conv. governor or mot. pot.
Master time control X
Over current protection
Over frequency protection
Over voltage protection
Over voltage protection, 3 phase
Phase difference indication
Power (overload) protection
(cos f)
Power factor (Cos φ) control
control
Power management
PT100 current transmitter X
Reverse power protection
RS232 programming interface X X X X X
RS485 communication interface, MODBUS RTU protocol X X X X X X
Short circuit protection
Speed adjustment X
Synchronizing signal output for load sharers
Synchronizing, DC control signal for electr. speed controllers
Synchronizing, pulse outputs for conv. governor or mot. pot.
Tacho detection X X
Under frequency protection
Under voltage protection
Under voltage protection, 3 phase
Unload
Unload trip
VAr load sharing
Voltage control
Voltage matching
Voltage regulation X

10
10 og on
tro

X
0A Ala
M4 lar rm ller
50 m An
An n

X
X
0- nu un
M4 M4 nc cia
70 iato tor

X
X
X
0-5 600
- r , 8
,2
M4 xI
nd M 4 c h
4c
ha
70 70 a nn nn

X
X
0-8 i ca
0I els els
M6 0 M tor
P n d
00 a ne i c a
OD t

X
0- l, s or
M8 M6 BU ire Pa
10 SI
0 10 n d na ne
ls

X
X
Sy 0P i ca nd
M8
10 n ch o we t o r, a lar
m

X
0- ro s rM s i re
N0 3X co an na rel
n ay
30 Sy
nc
pe ag
em da s

X
Product Overview

0P
h en l a r
T2
00
ro c ro s tS m
co y st re l

X
0 R ess L pe ay
T2 ev og w em s
10 ers ge ith
rS

X
eP
T2
0E
xc ow o ftw
Clo
sin
20 it er a re gC
Re

X
0 3 at i o n on
T2 P ha L os
lay tac
30 s s Re t

X
03 eO
T2 Ph ve l ay
40 rcu

X
X
0 3 ase S r re
T2 P h
ho
r nt
50 a s t Cir Re

X
03 eD
cu l ay
T2 P h ua i t
60 a s lO R el

X
0D eO ve
T2 ua ve r c u ay
Generator Monitoring

70 lC rcu r re
nt

X
X
0P urr r re
T2 ow en nt Re
80 er tR an l ay
ela

X
X
0O Re y
dS
T3
00 v e
l ay ho
rt
rcu
0 Cir

X
r re cu
T3 F re n t
00 qu
en o rE
it R
ela
c

X
X
T3
0-0
5D yR a rth y
10 ou e l ay F au
0

X
Vo ble lt R
T3 l ta Un ela
20
0 g e d e y
r

X
X
X
X
T3 Ins R ela Fre
30 ula
tio y q ue

X
03 nM nc
T3
Alarm & Indication

Ph o
yR
50 a s n i ela
y

X
0F eV to r
T4 re q olt
00 ue a g
nc eR

X
X
0A
T4 yD ela
30
u to
ev y
S yn i at

X
X
X
X
0L
T4 oa ch ion
30 dS ro n Re
ha ize l ay

X
X
X
X
X
0-3
T4 X r r, f
Lo
e r,
f o r
40
0L ad o re ele
S

X
X
X
T4 oa lec ctr
50 d S h a re t ro .s
0 h r , r n pe

X
X
X
X
X

A a r e ic ed
T4 e r, v.
p s p co
80
u to
f or o e e nt r
0 Sy
e
we dc

X
X
X
X
X
L n l r t o oll
T4 oa ch
ro n
ec
t ro r i p, n tro
ers
90 dS
un lle
ha ize nic r
l
X

T5
0V
Ar re r r sp o ad s
00 Lo , fo , fo r ee
0 ad rc co dc trip
P
X

on nv on
T8
40
a ra
l
Sh
a v en e n t r
re r tio tio oll
ers
0 B leling
na na
l ac R e l lg
o
ko
ut l a y go v e
ve
Lim rno rnor
i te rs s
r

11
Company Profile Generator Control Generator Protection

Power Management
The SELCO power management modules include the T2600 Dual Current
Relay for load depending start and stop and the M6000 Power Manager
together with the M6100 Selector Switch for a complete power manage-
ment system, where the level and sequence of start and stop can be ad-
justed.

This line of products also includes the T8400 Blackout Limiter which,
together with the M2000 Engine Controller, fulfils the minimum requirements
for control and protection of an unmanned engine room on board ships
according to the requirements of the ship classification societies.

M6000/M6100 Power T2600 Dual Current Relay


Management System
The M6000/M6100 is used in multi gen-
erator installations. The M6000 Power
Manager provides start and stop signals
to the M2000 Engine Controller, accord-
ing to the changing load demands. Each
generator requires one Power Manager.
On each unit parameters such as genera- The T2600 determines load depending
tor size, blackout capacity, start level, start and stop levels of the standby diesel
start/stop hysteresis, start and stop de- generator. When load increases on the
lays can be adjusted. running diesel generators more than e.g.
Flush mounted unit with standard 90%, adjustable, for a preset time, a start
measurements of 96 x 96 x 75mm. signal to call for the standby diesel gene-
rator will be provided. If the load decrea-
Used together with the ses below e.g. 45%, adjustable, for a pre-
M6100 Selector Switch set time, a stop signal will be provided to
an installation with up stop the standby diesel generator.
M2000 M2000 M2000
Watt Watt Watt to 6 generators can be
served, and the genera- The T2600 can serve an installation with
tor starting sequence can up to 3 diesel generators. With an exten-
G G G
be changed regularly in sion unit additional generators can be
a very easy manner. served.
Flush mounted unit
with standard measure-
ments of 144 x 144 x T8400 Blackout Limiter
70mm.
M6000 M6000 M6000
M6050 Reserve
Power Instrument
The M6050 is a useful
M6050 analog display showing
the percentage of re- The T8400 enables fast clearing of a
M6100
serve power available blackout. If a blackout occurs, the first
Power Management and Engine Control from the generators generator to have more than 90 % volt-
presently working. age will make the generator breaker
Flush mounted unit close. It is possible to monitor up to 4
with standard measure- generators with 1 unit, and up to 8 gene-
ments of 96 x 96 x rators with 2 units.
! „Succesful Development Departments 65mm.
focus equally on developing new
products and enhancing customer
benefits in existing solutions - just like
SELCO.“
Vagn Christensen, Area Sales Manager,
Demp A/S, Denmark
12
Product Overview Generator Monitoring Alarm & Indication

Power Monitoring
The SELCO power monitoring units are for monitoring the quality of the grid
(utility) or for monitoring the common busbar on board ships. SELCO offers
units for voltage and frequency monitoring, and the units have built-in
adjustable time delays and hysteresis. These units can e.g. give a signal to an
emergency controller to start up a standby generator when voltage or
frequency is outside tolerable range or to stop it again when it is back within
the acceptable range.

The power monitoring units also include an insulation monitoring relay


intended for insulation monitoring on board ships.

T3000 Frequency Relay T3200 Insulation Monitor T3500 Frequency Deviation Relay

The T3000 is intended for effective fre- The T3200 is intended for continuous The T3500 will continuously monitor
quency monitoring on generators, bus- insulation monitoring on 3 phase insu- any deviation in frequency in a grid
bars or other distribution systems. The lated networks on board ships. The relay where generators are operating in paral-
relay contains the functions “under fre- continuously monitors two systems gal- lel. With the grid connected, the system
quency” and “over frequency”, time vanically separated from each other, e.g. frequency is very stable, but if the grid is
delayed, and 2 individual output relays, the busbar and the lighting system or lost, subsequent frequency deviation
one relay for each function. two busbar systems. will be detected to trip the designated
system breaker in order to protect the
The unit features two output relays for generator.
T3100 and T3300 Voltage Relays alarm purposes and two analog outputs
for instrument readings.

E2323 Megaohmmeter and


E2324 Kiloohmmeter

The T3100 and T3300 are intended for


effective voltage monitoring on genera-
tors, busbars or other distribution systems.
The relays contain the functions “under
voltage” and “over voltage”, time de-
layed, and 2 individual output relays, The E2323 and E2324 are for connection
one for each function. to the Insulation Monitor T3200 for
instrument readings.
T3100 is for monitoring on one phase
and T3300 is for 3 phase monitoring. Flush mounted units with standard
measurements of 96 x 96 x 70mm.

13
Company Profile Generator Control Generator Protection

Engine Start and


Management
The SELCO Engine Controllers are based on decades of experience. The
most universal and flexible unit is the M2000 Engine Controller for the
complete control and protection of diesel generators. For emergency
generators, SELCO also provides the M2100 Emergency Controller. It is a unit
specifically aimed at control of an emergency generator. A number of
parameters can be configured on the two units via programming switches or
via a PC.

The controllers are ideal for both land-based as well as marine-based installa-
tions. The units have been type approved by the major marine classification
societies.
For use with the controllers the M0500 Tacho Voltage Detector has been
developed for detection of frequency and voltage levels.
For land-based installations the H2000 Engine Controller is a very compact
and universal unit. It includes relay outputs for alarms and shutdown for a
number of programmable parameters. The H2000 Engine Controller has a
built-in detection of frequency and voltage.

M2000 Engine Controller Flush mounted unit with standard


measurements of 144 x 144 x 35mm,
available in tightness class IP54 at the
front.

M2100 Emergency Controller

The M2000 provides complete control of


a diesel generator. It controls start and
stop of the engine, monitors and protects
the engine during start and operation.
At the same time it indicates all neces-
sary information about the conditions of
the generator via 10 LEDs on the front The M2100 provides complete control of
panel. an emergency diesel generator set. It
controls the start and stop, monitors and
The unit has 16 inputs for start/stop, protects the engine during start and ope-
crank disconnect, low oil pressure, ration. It also controls load transfer be-
alarms and other parameters, and 11 tween normal supply and the emergen-
outputs for connection of relays and an cy generator. At the same time it indi-
internal siren output relay. cates all necessary information about the
! „We have used SELCO for a number of conditions of the emergency generator
years now, and frequently use their Parameters like number of start attempts via 10 LEDs on the front panel.
products as a first choice solution for our and time sequences are programmable
various control applications. We find the
efficiency of their service a great help through 16 programming switches or via The unit has 16 inputs for start/stop,
during „break-down site“ situations.“ a PC through the built-in RS232 interface. crank disconnect, low oil pressure,
Lee Dainty, Purchaser, For readout of alarms and events the unit alarms and other parameters, and 11
Twyer Instrumentation Control & Switchgear, is also equipped with an RS485 interface open outputs for connection of relays
United Kingdom with standard MODBUS protocol. and an internal siren output relay.

14
Product Overview Generator Monitoring Alarm & Indication

Parameters like number of start which can be used to monitor e.g. high M0500 Tacho Voltage Detector
attempts and time sequences are water temperature. The M0600 has an
programmable through 16 input to indicate that the engine is run-
programming switches or via a PC ning and another input to indicate that
through the built-in RS232 interface. the engine is being stopped.
For readout of alarms and events the An output relay will give a closing sig-
unit is also equipped with an RS485 inter- nal, which can be used to stop the en-
face with standard MODBUS protocol. gine via the stop coil or the fuel valve.
The SELCO M2100 is for flush mounting
and is sized as a standard switchboard The M0600 will function as a stand-alone The M0500 will detect RPM (rotations
instrument. protection unit and is suitable for DIN- per minute) for disconnection of crank
Flush mounted unit with standard meas- rail mounting. Alternatively, when limit- and monitoring of running speed and
urements of 144 x 144 x 35mm, available ed space is available, the M0600 can be overspeed. The M0500 works in connec-
in tightness class IP54 at the front. mounted directly on the rear side of the tion with the M2000 Engine Controller
M2000 Engine Controller. This combina- and the M2100 Emergency Controller.
tion of the M2000 with the M0600 is ideal The M0500 will also detect when the
M0600 Shutdown Unit in situations, where additional redundant voltage of the generator exceeds 90% of
back-up protection is required. nominal level. This feature is used in
connection with the
Start & Stop
M2100 Emergency
Controller.

Crank The M0500 is for DIN


rail mounting. Alter-
natively, when limi-
ted space is available,
Fuel it can be mounted
Valve
directly on the rear
The M0600 mounted on the rear side of the Revs. side of the M2000 or
M2000 Engine Controller
M2100.
A switch on the unit
Shutdown
The M0600 provides protection for any Stop Alarms selects between two
type of diesel or gas engine. Solenoid input voltages, 230V
The unit has inputs for overspeed, low AC or 400V AC.
oil pressure and a user defined input The M2000 Engine Controller. Inputs and Outputs

H2000 Engine Controller


The H2000 is a very compact and uni-
versal unit for complete control and pro-
tection of diesel generators. It controls
the start and stop, monitors and protects
the engine during start and operation.
At the same time it indicates all neces-
sary information about the conditions of
the generator via 13 LEDs on the front
panel.

The unit has 10 inputs for remote


start / stop, crank disconnect, low oil
pressure, alarms and other parameters.
It also has inputs for direct connection to
the generator AC voltage, for built-in
detection of frequency and voltage. The
unit is provided with 7 built-in output
relays.
Parameters like number of start attempts
and time sequences are programmable
through 24 programming switches.
Flush mounted unit with standard
measurements of 96 x 96 x 70mm, avail-
H2000 Engine Controller able in tightness class IP54 at the front.

15
Company Profile Generator Control Generator Protection

Alarm Annunciators and


Indicators
SELCO supplies a number of alarm annunciators and indicator panels for use
in various applications.
The M4100 Alarm Annunciator is a compact 8 channel digital unit for use
with potential free closing or opening contacts.
The M1000 Alarm Annunciator is a highly flexible 10 channel microproces-
sor based unit. Several M1000 units can be interconnected in order to form
large alarm systems.
The M3000 Analog Alarm Annunciator is a very versatile 24 channel unit,
which can be used for monitoring of both potential free contacts and analog
levels such as current, temperature or pressure (through 4-20mA / 0-10V
DC transmitters). Both the M1000 and the M3000 alarm annunciators can
be configured manually or via a PC.
The SELCO indicator panels are for local or remote indication of alarms and
contact signals.

M1000 Alarm Annunciator The M1000 is also equipped with an


RS485 serial communication interface,
which supports the MODBUS RTU pro-
tocol.
Flush mounted unit with standard meas-
urements of 144 x 144 x 35mm, available
in tightness class IP54 at the front.

M4100 Alarm Annunciator

The M1000 is a compact 10 channel pro-


grammable unit with many features. An
input signal originating from a potential
free closing or opening contact (NO or
NC contact) will cause the appropriate
alarm LEDs to flash and simultaneously
the related output will activate. The in- The M4100 is a compact 8 channel pro-
ternal siren relay will be activated on the grammable unit with many features.
detection of every new alarm. The 8 inputs will accept any combina-
The M1000 unit has separate indications tion of normally open or normally closed
of first alarm, following alarms and ac- contacts. The inputs will cause the ap-
knowledged alarms. Multiple M1000 propriate alarm LED to flash and simul-
units can be interconnected to form a taneously activate the common siren
large-scale alarm system. relay. Additionally, each input can be
Alarm related parameters like time de- configured individually to activate one
lays, reset functions and other features or both of two alarm relays for group
can be configured through 16 program- alarm outputs.
ming switches. Alternatively, the M1000 Reset performed by the SIREN RESET
can be configured via the RS232 inter- button will silence the siren, where after
face from a standard ANSI terminal, e.g. it is possible to reset the alarm using the
a PC with the HyperTerminal application ALARM RESET button. The LED will
! „Working with SELCO, you cannot help
(which is a part of the Windows operat- then change to steady light and is main-
admiring the commitment to cooperation ...
internally as well as in customer relation- ing system). tained as long as the input signal is
ships.“ The unit can be configured for cable mon- present.
Hans-Erik Steen, Managing Director, itoring, and it can be configured to moni- Flush mounted unit with standard
H & E Steen Since 1976 AB, Sweden tor its own supply and insulation level. measurements of 96 x 96 x 75mm.

16
Product Overview Generator Monitoring Alarm & Indication

M1045 Test/Demonstration Board put for general alarm and an output for M1500 PT100 6 Way Transmitter
siren control.
An alarm is annunciated when the input
passes above or below a preset critical
level. The actual levels and alarm levels
are indicated on the display.
The configuration of the unit can be
done via the front panel or via a PC
through the built-in RS232 interface. The M1500 contains 6 current transmit-
The M1045 is made to simulate and eval- The M3000 is also equipped with an ters in one box to be connected to PT100
uate the many functions of the alarm RS485 serial communication interface temperature resistors. The outputs from
units, M1000 / M4100. All functions can with support for the MODBUS RTU the unit are 4-20mA current outputs
be simulated. The board is a unique aid protocol. according to DIN EN 60751. The current
when designing and testing a new alarm Flush mounted unit with standard outputs can be fed into e.g. analog alarm
system. measurements of 144 x 144 x 70mm, annunciators as the SELCO M3000.
The M1045 has an RS232 interface and tightness class IP54 at the front.
the Windows-based N0500 M-program- Each of the 6 inputs can individually be
mer is included in the M1045.This soft- set on the front to 3 different temperature
ware can be used for setting up parame- M3092 M-Programmer ranges: 0-160 °C, 0-300 °C or 0-600 °C.
ters on the previous version of the
M1000 without the built-in RS232 inter-
face. For the new M1000 with the built- M4500, M4600, M4700
in RS232 interface this program is a use- Indicator Panels
ful alternative to using an ANSI terminal
for configuration of parameters.

M3000 Analog Alarm


Annunciator

SELCO has developed a new user friend- The M4500, M4600 and M4700 Indicator
ly programming tool for the M3000. This Panels are intended for status indication
tool is delivered with the M3000 and al- of any process providing on / off out-
lows a very easy and flexible configura- puts. An input through a potential free
tion of all the parameters in the unit. contact will cause the appropriate alarm
The programming tool features a LED to light.
“spreadsheet-like” user interface. The
software checks and validates all the The indicator panels are an ideal solu-
parameters and gives printouts with a tion for local or remote indication of the
good overview. It is also possible to im- output signals from e.g. a PLC or alarm
The M3000 Analog Alarm Annunciator port / export all parameters into an annunciators as the SELCO M1000.
is a versatile unit with 24 channels, Excel spreadsheet.
which can be configured individually The panels contain 6, 8 or 20 channels.
for potential free contact inputs or ana- Level Dynamic Set Point The 20 channel M4700 is available in a
log inputs. Upper offset
Alarm Input ref. version with built-in alarm and siren
The analog inputs can be current or vol- relays. Also, there is a new version with
tage. Typically these inputs will come Set point an additional RS485 interface (MODBUS
from thermocouple transducers, PT100 Lower offset RTU). See further description on the
resistors, pressure transducers etc. following pages.
through current or voltage transmitters. Time
Flush mounted units with standard
Up to 48 alarms can be configured with Average Calculations measurements of 72 x 72 x 65mm, 96 x 96
individual reference to any of the 24 The M3000 can perform average calculations, x 65mm and 144 x 144 x 65mm, respec-
inputs. The alarms can be configured to which is useful for monitoring of the exhaust gas tively.
control one of the 24 LEDs on the front temperatures of diesel or gas engines. The aver-
age temperature for a number of cylinders is
panel and one of the 14 open collector
calculated. If the temperature of one of the
outputs. Several alarms can control the cylinders deviates from the average of the remain-
same LED and / or output. Furthermore ing cylinders more than a preset ± offset, a devia-
there is one common open collector out- tion alarm will be reported.

17
Company Profile Generator Control Generator Protection

Alarm Annunciators and Indicators


... continued

Modbus Indicators and Event Logging

The SELCO indicator panels H1500 and M4700-80 can be used for local or
remote indications of signal states, transmitted from e.g. a PLC through a
common 2-wire RS485 communication bus. The H1500 and M4700-80
supports the MODBUS RTU protocol.
The M4700-80 can also be used as a traditional indicator panel for simulta-
neous status indications from potential free contact inputs.
The H0300 Event Logger monitors and logs all alarms and events from the
SELCO alarm annunciators M1000 and M3000, as well as the M4700-80
MODBUS Indicator.
The H0300 can also act as an event repeater by transferring LED indications
from one unit to another via the RS485 interface, as defined by the user.
The N0300 Process Logger Software is a software package for PC based
logging of all alarms and events from SELCO alarm annunciators and engine
controllers.

H1500 Indicator Panel Flush mounted unit with standard


measurements of 96 x 144 x 70mm, tight-
ness class IP52 at the front.

M4700-80 MODBUS Indicator

The H1500 is a compact micro processor


based indicator panel for use in PLC
systems or in systems with the SELCO
H0300 Event Logger and SELCO alarm
annunciators. The unit provides an easy
and cost effective solution for clear indi-
cations at local or remote locations of
PLC registers or alarms. The M4700-80 is a versatile 20 channel
indicator panel, which can be used for
Communication with the units takes simultaneous monitoring of potential
place on a common 2-wire RS485 bus. free contacts and signal states transmit-
The communication protocol is the ted through a common 2-wire RS485
MODBUS RTU. Multiple H1500 units communication bus using the MODBUS
can be connected to a common RS485 RTU protocol.
bus. Maximum length of the RS485 bus
cable is approximately 1000 metres. This unit can best be described as a com-
The LEDs can be programmed, via the bination of a traditional indicator panel
bus, to perform various types of flashing, with potential free contacts and the bus
steady light or off state. The unit has com- based H1500 Indicator Panel.
! ”Any company can answer a phone 24
mands for reset of all LEDs, lamp test and
hours a day. Only few companies fly spare
parts to Iceland after working hours … the LEDs can be dimmed from 0 to 100%. The M4700-80 can also act as an alarm
SELCO did that for us.” A text description for the LEDs can be annunciator, as two internal relays can
Bjarni Astbjartson, Purchasing Manager, printed on a paper label, which slides in be used for group alarms and control of
VOLTI EHF, Iceland from the bottom. a high-powered external siren.

18
Product Overview Generator Monitoring Alarm & Indication

Additionally, it includes an internal si-


ren for local use.
Via the bus a PLC can read the state of
the LEDs and the inputs on the M4700-80.
This feature makes the M4700-80 a cost
effective remote 20 channel digital input
device with indications in PLC systems.
A text description for the LEDs can be
M4700-80 M1000 H1500
printed on the front plate legend card.
Flush mounted unit with standard
measurements of 144 x 144 x 65mm. RS485/MODBUS

H0300 Event Logger

RS232
H0300 Logger
PC with ANSI Centronics
Terminal Line Printer

Event Logging
The H0300 can log alarms and events
from SELCO alarm annunciators and
indicator panels, connected to a common
2-wire RS485 interface bus. Up to 63
units can be connected to the bus, where N0300 Process Logger
the maximum cable length is approx. The software N0300 provides PC based The units are connected to the RS485
1000 metres. logging of alarms and events on the bus via a 2-wire bus cable, where the
All events from the units are logged alarm annunciators M1000 and M3000 maximum length of the bus cable is 1000
with related date and time. The latest 32 and the engine controllers M2000 and metres.
events are stored in the internal memory M2100. The N0300 is capable of monitor-
of the H0300. A standard Centronics ing and control of up to 63 units. Log- The adaptor M0300 is an RS485 / RS232
printer can be used for printout of all ging can be performed on screen, printer converter. The connection between the
events. and hard disk and includes description adaptor and PC can be a direct link, a
The unit has a built-in siren relay, which of each event with related date and radio link or via the public telephone
will be activated on every new alarm. time. lines.
The alarms can be acknowledged at the
front panel.
The H0300 can also be configured to act
as an event repeater. It can transfer LED
indications from one unit to another
through the common bus. Multiple rela- M3000 M1000
tions between source units / LEDs and
destination units / LEDs, where to re-
peat the indications, can be defined.
M2000 M1000
Configuration can be done through the
built-in RS232 interface using a standard Printer
RS485
PC. The H0300 can also be used for test- M2100 M1000
ing various MODBUS RTU commands
on the RS485 interface via the PC. The
Modem Modem
commands are written in clear text on
the PC, and the H0300 will send the cor-
Phone Lines Adaptor
responding commands out on the RS485 RS232
interface according to the MODBUS Radio Link M0300
RTU protocol.
PC
Flush mounted unit with standard Direct Connection
measurements of 96 x 144 x 70mm, tight-
ness class IP52 at the front. Process Logging

19
SELCO Worldwide
SELCO Denmark Argentina Germany Malaysia South Africa
SELCO subsidiary Australia Greece Morocco Spain
SELCO representation
Austria Hong Kong Netherlands Sweden
Area of supply
Belgium Hungary Norway Taiwan

H e r l e v
Bulgaria Iceland Pakistan Thailand
China India Philippines Turkey

2 7 3 0
Croatia Indonesia Poland Ukraine
Czech Republic Iran Portugal United Kingdom

A / S ,
Egypt Italy Romania U.S.A.

p r o d u k t i o n
Finland Japan Russia
France Korea Singapore

G r a f i s k
T r y k B u r e a u e t
Q 1 0 0 1 - 1 4 E

Denmark: United Kingdom:


Meterbuen 6-12 13 Orton Enterprise Centre
DK-2740 Skovlunde Bakewell Road, Orton Southgate
w w w . c a r s t e n u l e n d o r f . d k

Telephone: + 45 - 70 26 11 22 Peterborough PE2 6XU


Telefax: + 45 - 70 26 25 22 Telephone: +44 (0) 1733 371828
www.selco.com Telefax: +44 (0) 1733 361434

You might also like