1-Φ INVETERS SPECIFICATION
Sl. Description capacity
No. 1.5 KW 2 KW 3 KW 5 KW
I Input (DC)
1 Max. Peak DC Input Power (KW) 2 KW 2.6 KW 3.9 KW 6.5 KW
2 Max. DC I/P (V dc) 500V 600V
3 Max. MPPT I/P Current (A) 20A
4 Max. Short Circuit Current (A) 30A
5 MPPT Tracking Voltage (Vdc) 70-500 Vdc
6 Min. Start Voltage (V) 80V
7 Number of MPPT Tracker 1
8 String per MPPT Trackers 1 2
II OUTPUT (AC)
1 Rated Output Power (KW) 1.5 KW 2 KW 3 KW 5 KW
2 Max. Peak Output Power 1.5 KW 2KW 3 KW 5 KW
3 Operating Grid Voltage (V) 195.5-264.5V (This can vary with grid standards)
4 Rated Grid Voltage (V) 220/230 0.85Un-1.1Un
5 Nominal Grid freq. (HZ) 50/45-55, 60/55-65Hz
6 Max. output current AC (A) 7.5/7.2A 10/9.6A 15/14.4A 25/24A
7 AC Connection (with PE) L/N/PE
8 THD (%) <3%
9 Output Power Factor (%) >99.99%
III Efficiency
1 Max. Conversion eff. (%) 97.3% 97.5%
2 Max. Euro Efficiency (%) 96.9% 97.0%
3 Max. MPPT Efficiency (%) >99%
IV Physical Parameters
1 Dimensions (LXHXW) mm 280×310×184 (Excluding Connectors and Brackets) 305×280×180
(Excluding
Connectors and
Brackets)
2 Weight (Kg) 6.35Kg 7.7Kg
General Data
1 Operating temperature -25 to +65℃, >45℃ Derating
2 Operating Surrounding Humidity 0-100%
3 Design Life Over 25 Years
4 Night Con. (W)/Noise Level <0.2/<35d B
5 Heat Dissipation Natural Cooling
6 RH / Max. Altitude 2000m 3000m
7 Display Graphical –LED with LCD Display
8 DC/AC Connectors (IP-65) MC-4 (DC)/ 3pin (AC)
9 Communication Interface RS485/RS232/GPRS/WIFI/Bluetooth/4G/LAN(optional) RS485/RS232/
WIFI/LAN
10 Standard Warranty 8 Years
V Standard, Safety & Protections
1 DC Switch N/A
2 SPD (Surge Protection Device) Type-2 DC MOV
3 Protection class 1
4 Efficiency IEC 61683
5 Safety Standard IEC 62109-1 & 2
6 EMC Standard IEC 62109-1 & 2
7 Environment Protection IEC 60068-2-1/2/14/30
8 Anti -Islanding IEC-62116
9 Ingress Protection IP 65
10 Utility Interface IEC-61727
-String Input -DC input short circuit -DC O/V &
Reverse Polarity
U/V
-Insulation Resistance -Output Over/Under -Output Over current
detection voltage
-Output Over/ Under -Over temperature -GDI for input & output
frequency
-Zero export protection -Anti – Islanding
11 Protection & Safety
12 The solar inverter should have the facility to monitor and control the
inverter remotely via Web application and mobile application.
Contractor will be liable for all communication charges of GPRS/GSM
Monitoring application mode for period of two years.
3-Φ INVETERS Specification (5/8/10/15KW)
Capacity
Sl. Description
5KW 8 KW 10KW 15 KW
I Input (DC)
Max. Peak DC
10.4
1 Input Power 6.5KW 13KW 19.5KW
KW
(KW)
Max. DC I/P (V
2 1100V DC
dc)
Max. MPPT I/P
3 20A+20A 20A+26A
Current (A)
Max. Short
4 Circuit Current 30A+30A 30A+39A
(A)
MPPT
5 Tracking 120-1000V 250-1000V
Voltage (Vdc)
Min. Start
6 140V 250V
Voltage (V)
Number of
7 2
MPPT Tracker
String per
8 1+1 1+1 1+1 1+2
MPPT Trackers
OUTPUT
II
(AC)
Rated Output
1 5 8 10 15
Power (KW)
Max. Peak
2 5.5 8.8 11 16.5
Output Power
Operating Grid
3 340V-460V (This can vary with grid standards)
Voltage (V)
Rated Grid
4 400V
Voltage (V)
Nominal Grid
5 50 / 60 (Optional)
freq. (HZ)
Max. output
6 8.3/8 13.3/12.8 16.7/15.9 25/23.9
current AC (A)
AC Connection
7 Three phase
(with PE)
8 THD (%) <3.5%
Output Power
9 >99.99%
Factor (%)
III Efficiency
Max.
1 Conversion 98.30% 98.50%
eff. (%)
Max. Euro
2 97.50%
Efficiency (%)
Max. MPPT
3 >99%
Efficiency (%)
Physical
IV
Parameters
283x463x178
Dimensions 330W×457H×203D (Excluding
1 (Excluding Connectors and
(LXHXW) mm connectors and brackets)
Brackets)
2 Weight (Kg) 11 15
General Data
Operating
1 -25º C to +65º C
temperature
Operating
2 Surrounding 0-100%
Humidity
3 Design Life Over 25 Years
Night Con.
4 (W)/Noise <0.2/<30d B <0.2/<40d B
Level
Heat
5 Natural Cooling Smart Cooling
Dissipation
RH / Max. 0% to 98%. No Condensation /<4000 without
6
Altitude power derating
7 Display Graphical –LED with LCD Display
DC/AC
8 Connectors (IP- MC-4(DC)/3pin(AC)
65)
Communication
9 Wifi/RS 485/RS 232/LAN
Interface
Standard
10 8 Years
Warranty
Standard,
V Safety &
Protections
1 DC Switch DC Switch available
SPD (Surge
2 Protection DC Type II / AC Type II
Device)
3 Protection class 1
4 Efficiency IEC 61683
5 Safety Standard IEC 62109-1 & 2
6 EMC Standard IEC 62109-1 & 2
Environment
7 IEC 60068-2-1/2/14/30
Protection
8 Anti -Islanding IEC-62116
Ingress
9 IP 65
Protection
10 Utility Interface IEC-61727
-DC
-DC O/V &
input short circuit
-String Input Reverse U/V
Polarity
-
Insulatio n Resistan ce -Output
detection -Output Over current
Over/Under voltage
Protection & -Output Over/ Under
11 -GDI for input & output
Safety
frequenc y -Over temperature
-Zero export protectio n
-Anti –
Islanding
The solar inverter should have the facility to monitor and control the inverter
remotely via Web application and mobile application.
Contractor will be liable for all communication
Monitoring charges of GPRS/GSM mode for period of two years.
12
application
3-Φ INVETERS Specification (20/25/30/40/50 KW)
Capacity
Sl. 40 50
No Description 20 KW 25 KW 33 KW
. KW KW
I Input (DC)
Max. Peak
1 DC Input 26KW 42.9 KW 52 KW 65 KW
Power (KW)
Max. DC I/P
2 1100V DC
(V dc)
Max. MPPT
3 I/P Current 26A+26A 40A+40A 3*40A 4*40A
(A)
Max. Short
4 Circuit 39A+39A 60A+60A 3*60A 4*60A
Current (A)
MPPT
Tracking
5 200-1000V
Voltage
(Vdc)
Min. Start
6 250V
Voltage (V)
Number of
7 MPPT 2 3 4
Tracker
String per
8 MPPT 2+2 3+3 3+3+3 3+3+3+3
Trackers
OUTPUT
II
(AC)
Rated Output
1 20 25 33 40 50
Power (KW)
Max. Peak
2 22 27.5 36.3 44 55
Output Power
Operating
3 Grid Voltage 340V-460V (This can vary with grid standards)
(V)
Rated Grid
4 400V
Voltage (V)
Nominal Grid
5 50 / 60 (Optional)
freq. (HZ)
Max. output
6 current AC 33.3/31.9 41.7/39.8 55/52.5 66.7/63.8 83.3/79.7
(A)
AC
7 Connection Three phase
(with PE)
8 THD (%) <3%
Output Power
9 >99.99%
Factor (%)
III Efficiency
Max.
1 Conversion 98.6 98.7
eff. (%)
Max. Euro
2 Efficiency 98 97.8 998
(%)
Max. MPPT
3 Efficiency >99% >99%
(%)
Physical
IV
Parameters
Dimensions 362×527×220(Exclud 362Wx577H×215D 434×570×243(Exclu
1 (LXHXW) ing Connectors (Excluding connectors and ding Connectors and
mm and Brackets) brackets) Brackets)
2 Weight (Kg) 20 23 37.1
General
Data
Operating
1 -25º C to +65º C
temperature
Operating
2 Surrounding 0-100%
Humidity
3 Design Life Over 25 Years
Night Con.
4 (W)/Noise <0.2/<40d B <0.2/<50d B
Level
Heat
5 Smart Cooling
Dissipation
0% to 98%. No
0% to 98%. No
RH / Max. Condensation
6 % to 98%. No Condensation Condensation /<4000
Altitude /<4000 without
/<2000 without power derating without power derating
power derating
7 Display LCD1602
DC/AC
8 Connectors MC-4(DC)/3pin(AC)
(IP-65)
Communicati
9 Wifi/RS 485/RS 232/LAN
on Interface
Standard
10 8 Years
Warranty
Standard,
V Safety &
Protections
1 DC Switch DC Switch available
SPD (Surge
2 Protection DC Type II / AC Type II
Device)
Protection
3 1
class
4 Efficiency IEC 61683
Safety
5 IEC 62109-1 & 2
Standard
EMC
6 IEC61000-6-2, 6-4 & IEC 61000-3-11, 3-12/IEC 61000-3-2, 3-3
Standard
Environment
7 IEC 60068-2-1/2/14/30
Protection
Anti -
8 IEC-62116
Islanding
Ingress
9 IP 65
Protection
Utility
10 IEC-61727
Interface
-String
Input
-DC input short circuit -DC O/V &
Reverse
Polarity
Protection &
11
Safety
-Output
Over/
Under -GDI for input &
output
frequenc
y -Over temperature
-Zero
export
protectio -Anti –Islanding
n
Monitoring The solar inverter should have the facility to monitor and control the inverter
12
application remotely via Web application and mobile application.