Professional Documents
Culture Documents
Manual Do Inversor Siemens
Manual Do Inversor Siemens
Related catalogs
Additional documentation
SINAMICS G110/SINAMICS G120 D 11.1
Inverter Chassis Units You will find all information material, such as brochures, catalogs,
SINAMICS G120D manuals and operating instructions for standard drive systems
Distributed Frequency Inverters up-to-date on the Internet at the address
Order No.: http://www.siemens.com/micromaster/printmaterial
German: E86060-K5511-A111-A4
English: E86060-K5511-A111-A4-7600 You can order the listed documentation or download it in common
file formats (PDF, ZIP).
SINAMICS G130 D 11
Drive Converter Chassis Units Catalog CA 01 – Selection tool SD configurator
SINAMICS G150 The selection tool SD configurator is available in combination with
Drive Converter Cabinet Units the electronic catalog CA 01.
Order No.:
German: E86060-K5511-A101-A3
English: E86060-K5511-A101-A3-7600
MICROMASTER/COMBIMASTER DA 51.3
MICROMASTER 411 Inverters
COMBIMASTER 411
Distributed Drive Solutions
Order No.:
German: E86060-K5251-A131-A2
English: E86060-K5251-A131-A2-7600
Industrial Communication IK PI
for Automation and Drives
Part 6: ET 200 Distributed I/O
ET 200S FC Frequency Converter On CD 2 for the selection and configuring tools, you will find the
Order No.: SD configurators for low-voltage motors, MICROMASTER 4 inverters,
German: E86060-K6710-A101-B5 SINAMICS G110 and SINAMICS G120 inverter chassis units as well
English: E86060-K6710-A101-B5-7600 as SINAMICS G120D distributed frequency inverters and SIMATIC
ET 200S FC frequency converters for distributed I/O, complete with:
• Dimension drawing generator for motors
Low-Voltage Motors D 81.1
IEC Squirrel-Cage Motors • Data sheet generator for motors and inverters
Frame sizes 56 to 450 • Starting calculation
• 3D models in STP format
Order No.:
German: E86060-K5581-A111-A2 • Extensive documentation
English: E86060-K5581-A111-A2-7600 Hardware and software requirements
• PC with 500 MHz CPU or faster
Low-Voltage Motors D 81.1 • Operating systems
IEC Squirrel-Cage Motors News – Windows 98/ME
New Generation 1LE1 – Windows 2000
Frame size 100 to 160 – Windows XP
Order No.: – Windows NT 4.0
German: E86060-K5581-A121-A2 (Service Pack 6 or higher)
English: E86060-K5581-A121-A2-7600
• 256 MB work memory (minimum)
• Screen resolution 1024 x 768, graphic with more than 256 colors,
AC NEMA & IEC Motors D 81.2 small fonts
Further details available on the U.S./ • 150 MB spare hard disk space (after installation)
Internet at: Canada
• CD-ROM drive
• Windows-compatible sound card
http://www.sea.siemens.com/motors • Windows-compatible mouse
Installation
MOTOX D 87.1 You can install this catalog directly from the CD-ROM as a partial
Geared Motors version or full version on your hard disk or in the network.
Order No.:
German: E86060-K5287-A111-A1
English: Catalog available soon
Catalog CA 01 CA 01
The Offline Mall of Automation and Drives
Order No.:
CD: E86060-D4001-A100-C6 (Germ.)
CD: E86060-D4001-A110-C6-7600 (Engl.)
DVD: E86060-D4001-A500-C6 (Germ.)
DVD: E86060-D4001-A510-C6-7600 (Engl.)
A&D Mall
Internet:
http://www.siemens.com/automation/mall
© Siemens AG 2007
420/430/440 0
Inverters
0.12 kW to 250 kW
Catalog DA 51.2
2007/2008 MICROMASTER Overview
Supersedes:
Catalog DA 51.2 · 2005/2006
1
The products in this catalog are also included
in the electronic catalog CA 01.
Order No.:
E86060-D4001-A110-C6-7600 (CD-ROM)
E86060-D4001-A510-C6-7600 (DVD) MICROMASTER 420 0.12 kW to 11 kW
Contact your local Siemens representative “The universal”
for further information
© Siemens AG 2007
2
3
The products and sys-
tems described in this
catalog are manufac-
tured/distributed under
application of a certified
quality management
system in accordance MICROMASTER 440 0.12 kW to 250 kW
with DIN EN ISO 9001
“The all-purpose”
(Certified Registration
No. DE-000357 QM)
and DIN EN ISO 14001
(Certified Registration
No. 0813420 UM and
EMS 57390). The cer-
4
tificate is recognized by
all IQNet countries.
Appendix
s A
© Siemens AG 2007
Ethernet
Management Level
MES Manufacturing Execution Systems
Ethernet
SINUMERIK SIMOTION
Computer Numeric Control Motion Control System
PROFINET
Field Level
Industrial Ethernet
Totally HART
Integrated
Automation
SIMATIC IT
SIMATIC WinCC
SCADA System
Totally
Integrated
Power
KNX/EIB
GAMMA instabus
Inverter
MICROMASTER
1/2 Selection guide
1/4 Options
Overview
■ Selection guide
Section 2
1/2 Siemens DA 51.2 · 2007/2008
© Siemens AG 2007
MICROMASTER 420/430/440
Overview
Section 3 Section 4
Siemens DA 51.2 · 2007/2008 1/3
© Siemens AG 2007
MICROMASTER 420/430/440
Overview
■ Options
Various options are available Assignment of operator panels and modules to the inverter ranges
for the MICROMASTER
inverters: Options Order No. MICROMASTER
410 1) 420 430 440
■ Filters
■ Chokes Operator panels
■ Operator panels OP 1) 6SE6400-0SP00-0AA0 %
■ PROFIBUS module BOP 6SE6400-0BP00-0AA0 % %
■ DeviceNet module
1 ■ CANopen module
BOP-2
AOP
6SE6400-0BE00-0AA0
6SE6400-0AP00-0AA1 %
%
%
■ Pulse encoder evaluation AAOP 6SE6400-0AP00-0AB0 % %
module CAOP 6SE6400-0AP00-0CA0 % %
■ Gland plates
Modules
■ Mounting kits, etc.
PROFIBUS 6SE6400-1PB00-0AA0 % % %
1) The MICROMASTER 410 is no DeviceNet 6SE6400-1DN00-0AA0 % % %
longer available. The model
will be discontinued as of CANopen 6SE6400-1CB00-0AA0 % % %
October 1, 2007. The Pulse encoder evaluation 6SE6400-0EN00-0AA0 % %
MICROMASTER 410 can then
only be ordered as a spare Maximum possible configuration: % Possible assignment
One pulse encoder evaluation module
part.
+ one communication module + one operator panel
Operator panels
Modules
Inverter
MICROMASTER 420
2/2 Description
2/9 Options
MICROMASTER 420
Description
MICROMASTER 420
Description
MICROMASTER 420
Circuit diagrams
PE
1/3 AC 200 - 240 V
3 AC 380 - 480 V
SI
2 DIN3
6 6
DIN3
~
7 7 =
+
_ 24 V PNP Output +24 V
max. 100 mA
or 8 (isolated) DC+
DC link
NPN Output 0 V
9 9 max. 100 mA DC−
(isolated) CPU
RL1-B
30 V DC/5 A (resistive load)
Relay 10 RL1-C
250 V AC/2 A (inductive load)
11
DAC+ =
0 - 20 mA D
12
max. 500 Ω DAC- A
3~
13
Not 60 Hz
used 50 Hz
P+
1 2
14 RS485 COM link
N- DIP switch
G_DA51_EN_00011
15
PE U,V,W
CB
option automatic
M
2
DIN4 3
4
+ – 9
24 V
MICROMASTER 420
Circuit diagrams
View A
DC link
terminals
Mains
connections
Motor
connections
2
View A
DAC+ DAC- P+ N-
G_DA51_EN_05106
12 13 14 15
Output relay
RL1
Analog output RS-485
(USS protocol)
5 6 7 8 9 10 11
PNP NPN
Output relay contacts
1 2 3 4
MICROMASTER 420
Technical data
MICROMASTER 420
Technical data
■ Derating data
Pulse frequency
Operating temperature
A D A 5 1 -5 0 1 7 e
1 0 0 2
R a te d o u tp u t c u rre n t
%
8 0
6 0
5 0
4 0
2 0
0
-1 0 0 1 0 2 0 3 0 4 0 5 0 6 0 °C 7 0
O p e r a tin g te m p e r a tu r e
100
Rated output current
%
80
60
40
20
0
0 1000 2000 3000 m 4000
Operational altitude
100
Mains voltage
%
80
77
60
40
20
0
0 1000 2000 3000 m 4000
Operational altitude
MICROMASTER 420
1) Supplementary conditions: inverter rated power and rated 2) Use of MICROMASTER invert- 3) Acc. to EMC EN 61800-3 gen-
Input current at rated operating mains voltage of 240 V or 400 V ers with internal filter is not per- erally suited to heavy industrial
point, applicable at short- without a line commutating missible on non-grounded (IT) applications. For details please
circuit voltage of the supply choke. mains supplies. refer to Appendix on page A/4.
Usc = 2 % with reference to the
MICROMASTER 420
Options
Variant dependent options
■ Overview
EMC filter, Class A Filter Class B with low LC filter In line with EN 61 000-3-2 reg-
leakage currents ulations “Limits for harmonic
Filter for inverters without an The LC filter limits the rate of
currents with device input cur-
internal filter for EMC filter for 1 AC 200 V to rise of voltage and the capac-
rent £16 A per phase”, there
– 3 AC 200 V to 240 V, 240 V inverters, frame sizes A itive charge/discharge cur-
are special aspects for drives
frame sizes A and B and B, without an internal EMC rents which usually occur with
with 250 W to 550 W and
– 3 AC 380 V to 480 V, filter Class A. inverter operation. This means
230 V single-phase supplies
frame size A. that much longer shielded mo-
With this filter, the inverter which can be used in non-in-
tor cables are possible when
All other inverters can be sup- complies with the emission dustrial applications (1st envi-
using LC filters and the ser-
plied with an internal Class A standard EN 55 011, Class B ronment).
vice life of the motor achieves
filter. for conducted interference
values similar to those with For devices with 250 W and
emissions. The leakage cur-
The requirements are fulfilled direct mains operation. 370 W, it is necessary either to
rents are reduced to
using shielded cables with a Use of an output choke isn’t fit the recommended input
< 3.5 mA.
max. length of 25 m. required with that. chokes or to apply to the pow-
The requirements are fulfilled er utility company for authori-
Please note when using
EMC filter, Class B using shielded cables with a zation to connect the devices
LC filters:
max. length of 5 m. to the public power supply.
Filter for inverters without an • Only V/f, FCC control per- No limits are currently defined
internal filter for Leakage currents:
missible in the EN 61 000-3-2 standard
– 3 AC 200 V to 240 V, The leakage currents of the in- • Please observe the derating for professionally used devic-
frame sizes A and B verters with/without filter (inter- of 15 % when selecting the es with a connected load
– 3 AC 380 V to 480 V,
frame size A.
nal/external) may exceed
30 mA. Typical values in prac-
appropriate inverter
• Operation only permissible
> 1 kW which means that the
inverters with an output power
2
tice are between 10 mA and with 4 kHz pulse frequency ³ 0.75 kW comply with the
With this filter, the inverter 50 mA. The exact values de- • The output frequency is lim- EN 61 000-3-2 standard.
complies with the emission pend on the design, environ- ited to 150 Hz
standard EN 55 011, Class B However, in accordance with
ment and cable lengths. Inter- • Operation and commission-
for conducted interference the regulations of EN 61000-3-
ference-free operation with re- ing only with connected mo-
emissions. 12 “Limits for harmonic cur-
sidual current operated devic- tor as the LC filter is not
rents > 16 A and £ 75 A per
The requirements are fulfilled es with a trigger value of idling-proof!
phase” an approval is neces-
using shielded cables with a 30 mA cannot be guaranteed.
The LC filters can be used for sary from the power supplier
max. length of 25 m. However, operation with resid-
all MICROMASTER 420 invert- for drives that are intended to
ual current circuit-breakers
ers of frame sizes A to C. be connected to the public
Additional EMC filter, with a trigger value of 300 mA
low-voltage network. Please
Class B is possible. Please refer to the
Line commutating choke refer to the Operating Instruc-
Instruction Manual for details.
Available for inverters with an tions for the values of the har-
Line commutating chokes
internal Class A EMC filter. monic currents.
are used to smooth voltage
With this filter, the inverter peaks or to bridge commutat-
Output choke
complies with the emission ing dips. In addition, line com-
standard EN 55 011, Class B mutating chokes reduce the Output chokes can be sup-
for conducted interference effects of harmonics on the in- plied for reducing the capaci-
emissions. verter and the power supply. If tive currents and dV/dt in the
the line impedance is <1 %, a case of motor cables > 50 m
The requirements are fulfilled line commutating choke must (shielded) or > 100 m (un-
using shielded cables with a be used in order to reduce the shielded).
max. length of 25 m. current peaks.
For max. permissible cable
lengths, see Technical Data.
Gland plate
The gland plate facilitates the
shield connection of power
and control cables and en-
sures optimum EMC perfor-
mance.
MICROMASTER 420
Options
Variant dependent options
■ Technical data
LC filter
Max. permissible cable lengths from the motor to the inverter when using output chokes
The following table shows the
maximum permissible cable
lengths from the motor to the
inverter when using output
chokes.
Frame size Output choke Max. permissible motor cable lengths (shielded/unshielded)
for a mains voltage of
(FS) Type 200 V to 240 V ± 10 % 380 V to 400 V ± 10 % 401 V to 480 V ± 10 %
A 6SE6400-3TC00-4AD3 200 m/300 m – –
A 6SE6400-3TC00-4AD2 200 m/300 m 150 m/225 m 100 m/150 m
B 6SE6400-3TC01-0BD3 200 m/300 m 150 m/225 m 100 m/150 m
C 6SE6400-3TC03-2CD3 200 m/300 m 200 m/300 m 100 m/150 m
MICROMASTER 420
Options
Variant dependent options
■ Design
General installation instructions
■ A maximum of two footprint ■ The EMC filter must be
components plus inverter mounted directly below the
are permissible. frequency inverter if pos-
■ If an LC filter is used, it must sible.
be mounted directly on the ■ If mounted on the side, the
wall of the control cabinet line-side components are to
due to weight reasons. be mounted to the left of the
G_DA51_EN_05016d
If an LC filter of frame size C frequency inverter whereas
is used, therefore, only one the output-side compon-
footprint component is per- ents are to be mounted to
missible. If a line choke and the right of the frequency
Position 2
LC filter are used, the line inverter.
choke must be located on
the left of the inverter.
Required distance between
line choke and inverter: Position 1
75 mm.
2
Example of installation with frequency inverter,
EMC filter (position 1) and line choke (position 2)
Frame size
A B C
Line commutating choke ✓ ✓ ✓
EMC filter ✓ ✓ ✓
LC filter ✓ ✓ ✓
Output choke ✓ ✓ ✓
MICROMASTER 420
Options
Variant dependent options
MICROMASTER 420
Options
Variant dependent options
MICROMASTER 420
Options
Variant dependent options
MICROMASTER 420
Options
Variant independent options
■ Overview
Basic Operator Panel (BOP) Asian Advanced Operator DeviceNet module Connection kit for PC
Panel (AAOP) to AOP
With the BOP, individual pa- For networking the inverters to
rameter settings can be made. The AAOP is the Chinese ver- the DeviceNet fieldbus system For connecting a PC to an
Values and units are shown on sion of the AOP operator pan- widely used on the American AOP or AAOP. Offline pro-
a 5-digit display. el. It has an enhanced display market. A maximum transmis- gramming of inverters and ar-
and supports the operating sion rate of 500 Kbaud is pos- chiving of parameter kits pos-
languages of Chinese (simpli- sible. Remote control of the in- sible. Includes a desktop at-
fied) and English. verter is possible with the De- tachment kit for an AOP or
viceNet module. Remote con- AAOP, an RS-232 standard
trol and operation at the invert- cable (3 m) with Sub-D con-
er can be combined using an nectors and a universal power
operator panel plugged onto supply unit.
the DeviceNet module.
Operator panel door mount-
The connection to the De-
ing kit for single inverter
viceNet bus system is made
using a 5-pin connector with For mounting an operator pan-
terminal strip. el in a control cabinet door.
Degree of protection IP56.
CANopen module Contains a cable adapter
Basic Operator Panel (BOP)
module with screwless termi-
Using the CANopen commu-
nals for use with user's own
A BOP can be used for several
inverters. It can be directly Asian Advanced Operator Panel
nications module, an inverter
can be linked to the CANopen
RS-232-cables 1). 2
(AAOP) fieldbus system and remote
mounted on the inverter or in a AOP door mounting kit for
control cabinet door using a control is then possible.
Cyrillic Advanced Operator multiple inverters (USS)
mounting kit. Remote control and operation
Panel (CAOP) For mounting an AOP or AAOP
at the inverter can be com-
Advanced Operator Panel The CAOP is the Cyrillic ver- in a control cabinet door.
bined using an operator panel
(AOP) sion of the AOP Advanced Degree of protection IP56. The
plugged onto the CANopen
Operator Panel. It supports AOP or AAOP can communi-
The AOP enables parameter module.
the Cyrillic, German and En- cate with several inverters by
kits to be read out of the invert- The module is connected to means of the RS-485 USS
glish operator languages.
er or to be written into the in- the bus system through a protocol. The 4-pin connect-
verter (upload/download). Dif- 9-pin Sub-D connector. ing cable from the AOP or
PROFIBUS module
ferent parameter kits can be AAOP to the RS-485 terminals
stored in the AOP. It has a For a complete PROFIBUS Connection kit for of the inverter and to the 24 V
plain text display with the pos- connection with up to PC to inverter user terminal strip is not
sibility of switching between £12 Mbaud. Remote control included 2).
several languages. of the inverter is possible with For controlling an inverter di-
the PROFIBUS module. Re- rectly from a PC if the appro-
Start-up tools
mote control and operation at priate software has been in-
the inverter can be combined stalled (e.g. STARTER). • STARTER
using an operator panel Isolated RS-232 adapter mod- is a graphic start-up soft-
plugged onto the PROFIBUS ule for reliable point-to-point ware for guided start-up for
module. The PROFIBUS mod- connection to a PC. Includes a MICROMASTER 410/420/
ule can be supplied by an ex- Sub-D connector and an 430/440 frequency inverters
ternal 24 V DC power supply RS-232 standard cable (3 m). under Windows 2000/XP
and is thus also active when Professional. Parameter lists
the inverter is disconnected can be read out, altered,
from the power supply. stored, entered and printed.
Connection by means of a • DriveMonitor
9-pin Sub-D connector (avail- is a start-up software for list-
able as an option). oriented programming of
Advanced Operator Panel (AOP) frequency inverters. This
program executes under
Up to 30 inverters can be con- Windows 98/NT/2000/ME/
trolled from an AOP via USS. It XP Professional.
can be directly mounted on
the inverter or in a control cab- Both programs are included
inet door using a mounting kit. on the Docu DVD which is pro-
vided with every inverter.
MICROMASTER 420
Options
Variant independent options
MICROMASTER 420
Options
Variant independent options
• Transport
Acceleration
Deflection
Acceleration
19.6 m/s2 in the frequency range of 58 Hz to 500 Hz
3.5 mm in the frequency range of 5 Hz to 9 Hz
9.8 m/s2 in the frequency range of 9 Hz to 500 Hz
2
Climatic category (during operation) 3K3 to DIN IEC 60 721-3-3
Cooling method Natural air cooling
Permissible ambient or cooling agent temperature
• Operation –10 °C to +50 °C (+14 °F to +122 °F)
• Storage –40 °C to +70 °C (–40 °F to +158 °F)
• Transport –25 °C to +70 °C (–13 °F to +158 °F)
Relative humidity
(permissible humidity rating)
• Operation £ 85 % (non-condensing)
• Storage and transport £ 95 %
Power supply The CAN bus is supplied from the inverter power supply
Data transmission rate 10, 20, 50, 125, 250, 500, 800 Kbaud and 1 Mbaud
Documentation
1) The DVD contains operating Available on the Internet: STARTER at 2) Available on the Internet at
instructions, parameter list, DriveMonitor at http://support.automation. http://support.automation.
commissioning tools STARTER http://support.automation. siemens.com/WW/view/en/ siemens.com/WW/view/en/
and DriveMonitor, multilan- siemens.com/WW/view/en/ 10804985/133100 10804926/133300
guage. 10804984/133100
MICROMASTER 420
Dimension drawings
(2.28)
58
173 (6.81)
160 (6.29)
DIN Rail
ADA51-5000e
ADA51-5007c
147 (5.79)
195 (7.68)
Fixing with
2 x M4 bolts, 2 x M4 nuts, 2 x M4 washers,
(5 149
7)
Drill pattern
174 (6.85)
G_DA51_EN_05001d
ADA51-5008b
202 (7.95)
258 (10.16)
138 (5.43)
(6 172
Fixing with
7)
.7
Drill pattern
204 (8.03)
ADA51-5009b
245 (9.65)
ADA51-5002d
309 (12.16)
174 (6.85)
Fixing with
(7 195
8)
MICROMASTER 420
Dimension drawings
38 185 (7.28)
(1.5) 156 (6.14)
24 149 (5.87)
73 (2.87)
(0.94) 120 (4.72)
56 (2.2)
4 x M4
4 x M4
219 (8.62)
232 (9.13)
2 x M4
187 (7.36)
200 (7.87)
245 (9.65)
204 (8.03)
174 (6.85)
187 (7.36)
213 (8.39)
174 (6.85)
200 (7.87)
160 (6.3)
G_DA51_EN_00061
G_DA51_EN_00063
G_DA51_EN_00062
43.5 (1.71) 50.5 (1.99) 55 (2.17)
138 174
(5.43) (6.85)
2
c b
c b
d
e
a
DA51-5013e
c b
c b
DA51-5049
Output choke
for frame size A For frame sizes B and C
6SE6400-3TC00-4AD2 6SE6400-3TC01-0BD3
6SE6400-3TC00-4AD3 6SE6400-3TC03-2CD3
MICROMASTER 420
Dimension drawings
■ LC filter
280 (11.02)
287 (11.3)
293 (11.53)
300 (11.81)
340 (13.38)
334 (13.15)
G_DA51_EN_05080
G_DA51_EN_05077
G_DA51_EN_05079
G_DA51_EN_05076
56 120
(2.2) (4.72)
174 (6.85)
320 (12.6)
335 (13.19)
382 (15.04)
G_DA51_EN_05078a
G_DA51_EN_05081
156 (6.14)
Inverter
MICROMASTER 430
3/2 Description
3/10 Options
MICROMASTER 430
Description
MICROMASTER 430
Description
MICROMASTER 430
Circuit diagrams
PE
3 AC 380 - 480 V
SI
PE L/L1, N/L2,
+ 10 V
1 L3
or
0V
2 L1, L2, L3
ADC1+
≥ 4,7 k Ω AA/
3 BOP link
ADC1- DD
4
ADC2+ RS232
AA/
10 150.00
ADC2- DD
24 V external 11
BOP-2
DIN1 DIN1
5 5
DIN2 DIN2 ~
~
6 6
Opto isolation
DIN3 DIN3 ==
7 7
DIN4 DIN4 Frame sizes
8 8 C to F B+/DC+
DIN5 DIN5 DC-
16 16
DIN6 DIN6
+ 17 17 Output +24 V
PNP max. 100 mA
_ 24 V or 9 (isolated)
NPN Output 0 V Terminals only
max. 100 mA for measuring
28 28 (isolated) Frame sizes DCNA purposes
PTCA FX and GX
Motor DCPA
14 A
PTC/
PTCB D
KTY 84
3 15
DAC1+
CPU DCNS
DCPS
0 - 20 mA D
12
max. 500 DAC1- A
13 =
DAC2+
0 - 20 mA 26 D 3 ~
max. 500 DAC2- A
27
COM
20 NO Not 60 Hz
Relay 1 used 50 Hz
19 NC
1 2
18 DIP switch
(on control board)
COM
30 V DC/5 A (resistive load)
Relay 2 22 NO
250 V AC/2 A (inductive load)
21
ADC ADC
0 - 20 mA 1 2 DIP
COM current switch
25 NO 0 - 10 V (on I/O
Relay 3 voltage board)
24 NC 1 2
23
G_DA51_EN _00012
P+
29 RS485 COM link
N-
30
PE U, V, W
CB automatic M
option
MICROMASTER 430
Circuit diagrams
View A
Mains connections
Motor connections
View A
AIN1 AIN2 RL1-A RL1-B RL1-C RL2-B RL2-C RL3-A RL3-B RL3-C
G_DA51_EN_05107
S1 S2
18 19 20 21 22 23 24 25
DIP Switches:
0 mA to 20 mA
or Output relay contacts
0 V to 10 V
3
DAC1+ DAC1- PTC PTC DIN5 DIN6 DAC2+ DAC2- PE P+ N-
A B 0V
12 13 14 18
15 16 17 26 27 28 29 30
NPN *)
+10 V 0V ADC1+ ADC1- DIN1 DIN2 DIN3 DIN4 +24 V ADC2+ ADC2-
(DIN7) (DIN8)
1 2 3 4 5 6 7 8 9 10 11
PNP *)
MICROMASTER 430
Technical data
MICROMASTER 430
Technical data
■ Derating data
Pulse frequency
Operating temperature
100 1 0 0
Rated output current
R a te d o u tp u t c u rre n t
% 8 5
80 8 0
70 %
60 6 0
40 4 0
20 2 0 3
0 0
-10 0 10 20 30 40 °C 50 0 1 0 2 0 3 0 4 0 4 5 °C 5 5
Operating temperature O p e r a tin g te m p e r a tu r e
MICROMASTER 430
Technical data
100 100
Rated output current
40 40
20 20
0 0
0 1000 2000 3000 m 4000 0 1000 2000 3000 m 4000
Operational altitude Operational altitude
100 100
Mains voltage
Mains voltage
% %
80 80
77 77
60 60
40 40
20 20
0 0
0 1000 2000 3000 m 4000 0 1000 2000 3000 m 4000
Operational altitude Operational altitude
MICROMASTER 430
1) Supplementary conditions: 2) Supplementary conditions: 3) Use of MICROMASTER invert- 4) Acc. to EMC EN 61800-3 gen-
Input current at rated operating Input current at rated operating ers with internal filter is not per- erally suited to heavy industrial
point, applicable at short-cir- point, applicable at short-cir- missible on non-grounded applications. For details please
cuit voltage of the supply cuit voltage of the supply mains supplies. refer to Appendix on page A/4.
USC = 2 % with reference to the USC ⱖ 2.33 % with reference to
inverter rated power and rated the inverter rated power and
mains operating voltage of rated mains voltage of 400 V.
400 V without a line commutat-
ing choke.
MICROMASTER 430
Options
Variant dependent options
■ Overview
EMC filter, Class A The requirements are fulfilled LC filter and sinusoidal filter The LC filters/sinusoidal filters
using shielded cables with a can be used for all MICRO-
All 7.5 kW to 90 kW inverters The LC filter/sinusoidal filter
max. length of 25 m to 50 m MASTER 430 inverters of
are supplied with an internal limits the rate of rise of voltage
(depending on the type, de- frame sizes C to GX.
filter Class A. and the capacitive charge/
tails on request).
For inverters 110 kW to discharge currents which usu- • Frame sizes D to F:
250 kW, EMC filters Class A With this filter, the inverter ally occur with inverter opera- The LC filters, frame sizes D
are available. In this perfor- complies with the emission tion. This means that much to F, are designed for
mance range, the EMC filters standard EN 55 011, Class B longer shielded motor cables mounting upright in the con-
are only permitted to be used for conducted interference are possible when using LC trol cabinet. Due to leakage
in combination with a line emissions. filters/sinusoidal filters and the flux lines caused by physical
commutating choke. service life of the motor sources, a minimum dis-
Leakage currents:
achieves values similar to tance of 50 mm to adjacent
The requirements are fulfilled
The leakage currents of the in- those with direct mains opera- modules and metal parts is
using shielded cables with a
verters with/without filter (inter- tion. Use of an output choke recommended.
max. length of 25 m.
nal/external) may exceed isn’t required with that.
• Frame sizes FX and GX:
30 mA. Typical values in prac-
EMC filter, Class B Please note when using The sinusoidal filters, frame
tice are between 10 mA and
LC filters/sinusoidal filters: sizes FX and GX, are de-
Available for inverters 7.5 kW 50 mA. The exact values de-
signed for mounting upright
to 15 kW with an internal Class pend on the design, environ- • Only V/f, FCC control per-
in the control cabinet. Due to
A EMC filter. ment and cable lengths. Inter- missible
leakage flux lines caused by
ference-free operation with • Please observe the derating
The requirements are fulfilled physical sources, a mini-
residual current operated de- of 15 % when selecting the
using shielded cables with a mum distance of 100 mm to
vices with a trigger value of appropriate inverter
max. length of 25 m. adjacent modules and metal
30 mA cannot be guaranteed. • Operation only permissible
parts is recommended.
For inverters 18.5 kW to 90 kW with 4 kHz pulse frequency
However, operation with resid-
without filters, EMC filters of Note: Please observe derat-
ual current operated devices
Class B from Schaffner can be ing for frame sizes FX and
with a trigger value of 300 mA
used. GX.
is possible. Please refer to the
• The output frequency is lim-
Instruction Manual for details.
ited to 150 Hz
• Operation and commission-
ing only with connected mo-
tor as the LC filter/sinusoidal
filter is not idling-proof!
3
■ Technical data
LC filter and sinusoidal filter
MICROMASTER 430
Options
Variant dependent options
MICROMASTER 430
Options
Variant dependent options
■ Overview
Line commutating choke No limits are currently defined Output choke Gland plate
in the EN 61 000-3-2 standard
Line commutating chokes are Output chokes can be sup- Gland plates are available for
for professionally used devic-
used to smooth voltage peaks plied for reducing the capaci- inverters of frame size C. All
es with a connected load
or to bridge commutating tive compensation currents the other frame sizes have the
> 1 kW.
dips. and dV/dt in the case of motor shield connection for the con-
In addition, line commutating This means that the inverters cables >50 m (shielded) or trol cable integrated in the in-
chokes reduce the effects of with an output power > 100 m (unshielded). verter.
harmonics on the inverter and ³ 0.75 kW comply with the
For max. permissible cable The shield for the power cable
the power supply. If the line EN 61 000-3-2 standard.
lengths, see Technical Data. has to be connected external-
impedance is < 1 %, a line
However, in accordance with ly (e.g. in the control cabinet).
commutating choke must be
the regulations of EN 61000-3- Exception: Inverters of frame
used in order to reduce the
12 “Limits for harmonic cur- sizes D and E and frame size
current peaks.
rents > 16 A and £ 75 A per F with integrated class A filter.
phase” an approval is neces- In this case the shield con-
sary from the power supplier nection is integrated in the in-
for drives that are intended to verter.
be connected to the public
The gland plate facilitates the
low-voltage network. Please
shield connection of power
refer to the Operating Instruc-
and control cables and thus
tions for the values of the har-
ensures optimum EMC perfor-
monic currents.
mance.
■ Technical data
Max. permissible cable Note:
lengths from the motor to
Operation up to 150 Hz output
the inverter when using out-
frequency only!
put chokes
The following table shows the
maximum permissible cable
lengths from the motor to the
inverter when using output
chokes.
3
Frame size Output choke Max. permissible motor cable lengths (shielded/unshielded)
for a mains voltage of
(FS) Type 380 V to 400 V ± 10 % 401 V to 480 V ± 10 %
C 6SE6400-3TC03-2CD3 200 m/300 m 100 m/150 m
D to F 6SE6400-3TC . . -. . D0 200 m/300 m 200 m/300 m
FX 6SL3000-2BE32-1AA0 300 m/450 m 300 m/450 m
FX 6SL3000-2BE32-6AA0 300 m/450 m 300 m/450 m
GX 6SL3000-2BE33-2AA0 300 m/450 m 300 m/450 m
GX 6SL3000-2BE33-8AA0 300 m/450 m 300 m/450 m
GX 6SL3000-2BE35-0AA0 300 m/450 m 300 m/450 m
MICROMASTER 430
Options
Variant dependent options
■ Design
General installation instructions
■ A maximum of two footprint ■ The EMC filter must be
components plus inverter mounted directly below the
are permissible. frequency inverter if pos-
■ If an LC filter is used, it must sible.
be mounted directly on the ■ If mounted on the side, the
wall of the control cabinet line-side components are to
due to weight reasons. be mounted to the left of the
G_DA51_EN_05042c
If an LC filter of frame size C frequency inverter whereas
is used, therefore, only one the output-side compon-
footprint component is per- ents are to be mounted to
missible. If a line choke and the right of the frequency
LC filter are used, the line inverter. Position 2
choke must be located on
the left of the inverter.
Required distance between Position 1
line choke and inverter:
75 mm.
Frame size
C D E F G FX GX
Line commutating choke ✓ ✓ ✓
EMC filter ✓
LC filter
Output choke
✓
✓
3
Recommended combinations of inverters and options
MICROMASTER 430
Options
Variant dependent options
MICROMASTER 430
Options
Variant dependent options
MICROMASTER 430
Options
Variant independent options
■ Overview
Basic Operator Panel 2 PROFIBUS module CANopen module Start-up tools
(BOP-2)
For a complete PROFIBUS Using the CANopen commu- • STARTER
With the BOP-2, individual pa- connection with up to nications module, an inverter is a graphic start-up soft-
rameter settings can be made. £12 Mbaud. Remote control can be linked to the CANopen ware for guided start-up for
Values and units are shown on of the inverter is possible with fieldbus system and remote MICROMASTER 410/420/
a 5-digit display. the PROFIBUS module. Re- control is then possible. 430/440 frequency inverters
mote control and operation at under Windows 2000/
Remote control and operation
the inverter can be combined XP Professional. Parameter
at the inverter can be com-
using an operator panel lists can be read out, al-
bined using an operator panel
plugged onto the PROFIBUS tered, stored, entered and
plugged onto the CANopen
module. The PROFIBUS mod- printed.
module.
ule can be supplied by an ex-
• DriveMonitor
ternal 24 V DC power supply The module is connected to
is a start-up software for list-
and is thus also active when the bus system through a
oriented programming of
the inverter is disconnected 9-pin Sub-D connector.
frequency inverters. This
from the power supply.
program executes under
Connection kit for
Connection by means of a Windows 98/NT/2000/ME/
PC to inverter
9-pin Sub-D connector (avail- XP Professional.
able as an option). For controlling an inverter di-
Both programs are included
rectly from a PC if the appro-
Basic Operator Panel (BOP-2) on the Docu DVD which is pro-
DeviceNet module priate software has been in-
vided with every inverter.
stalled (e.g. STARTER).
A BOP-2 can be used for sev- For networking the inverters to
Isolated RS-232 adapter mod-
eral inverters. It can be direct- the DeviceNet fieldbus system
ule for reliable point-to-point
ly mounted on the inverter or in widely used on the American
connection to a PC. Includes a
a control cabinet door using a market. A maximum transmis-
Sub-D connector and an
mounting kit. sion rate of 500 kbaud is pos-
RS-232 standard cable (3 m).
sible. Remote control of the in-
verter is possible with the
Operator panel door mount-
DeviceNet module.
ing kit for single inverter
Remote control and operation
For mounting an operator pan-
at the inverter can be com-
el BOP-2 in a control cabinet
bined using an operator panel
door. Degree of protection
plugged onto the DeviceNet
3 module.
IP56. Contains a cable adapt-
er module with screwless ter- 1) A shielded cable of type
The connection to the minals for use with user's own Belden 8132 (28 AWG) is
DeviceNet bus system is RS-232 cables 1). recommended.
The maximum cable length is
made using a 5-pin connector 5 m for RS-232.
with terminal strip.
MICROMASTER 430
Options
Variant independent options
MICROMASTER 430
Options
Variant independent options
Documentation
1) The DVD contains operating Available on the Internet: STARTER at 2) Available on the Internet at
instructions, parameter list, DriveMonitor at http://support.automation. http://support.automation.
commissioning tools STARTER http://support.automation. siemens.com/WW/view/en/ siemens.com/WW/view/en/
and DriveMonitor, multilan- siemens.com/WW/view/en/ 10804985/133100 10804926/133300
guage. 10804984/133100
MICROMASTER 430
Dimension drawings
Drill pattern
204 (8.03)
ADA51-5009b
245 (9.65)
309 (12.16)
ADA51-5002d
174 (6.85)
Fixing with
(7 195
8)
4 x M5 bolts
.6
4 x M5 nuts
185 (7.28) 4 x M5 washers
Inverter frame size C Tightening torque with washers fitted:
3.0 Nm
Inverter frame size C
Ventilation clearance required at top with gland plate
and bottom: 100 mm
Drill pattern
Drill pattern
3
616.4 (24.27)
650 (25.59)
520 (20.47)
486 (19.13)
ADA51-5021b
ADA51-5020b
235 (9.25)
235 (9.25)
(9 245
5)
(9 245
5)
.6
MICROMASTER 430
Dimension drawings
Drill pattern
Drill pattern
1110 (43.70)
1150 (45.28)
850 (33.46)
810 (31.89)
ADA51-5023b
ADA51-5022b
(1 320
6)
6)
4 x M8 bolts 4 x M8 bolts
2.
2.
MICROMASTER 430
Dimension drawings
Drill pattern
Drill pattern
125 125
(4.92) (4.92)
125 125
(4.92) (4.92)
1508 (59.37)
1533 (60.35)
1375 (54.13)
1400 (55.12)
G_DA51_EN_05075
G_DA51_EN_05074
125 125
(4.92) (4.92)
3
125 125
1. 5
)
(4.92) (4.92)
46
(2 54
4. 6
)
06
(1 35
Fixing with
326 Fixing with 326 6 x M8 bolts
(12.83) 6 x M8 bolts (12.83) 6 x M8 nuts
6 x M8 nuts 6 x M8 washers
Inverter frame size FX 6 x M8 washers Inverter frame size GX
Tightening torque
Tightening torque with washers
with washers fitted: 13.0 Nm
fitted: 13.0 Nm Ventilation clearance
Ventilation clearance required:
required: at top: 250 mm
at top: 250 mm at bottom: 150 mm
at bottom: 150 mm in front: 50 mm
in front: 40 mm
MICROMASTER 430
Dimension drawings
■ EMC filter
38 185 (7.28)
(1.5) 156 (6.14)
4 x M4
219 (8.62)
232 (9.13)
245 (9.65)
204 (8.03)
G_DA51_EN_00063
55 (2.17)
174
(6.85)
b1
n4
b
c
n3
a
a1
G_DA51_XX_05103
MICROMASTER 430
Dimension drawings
■ LC filter
174 (6.85)
320 (12.6)
335 (13.19)
382 (15.04)
G_DA51_EN_05078a
G_DA51_EN_05081
156 (6.14)
(FS)
a b c n1 n2 kg
6SE6400-3TD03-7DD0 D 278 240 230 115 190 21.0
(10.94) (9.45) (9.06) (4.53) (7.48)
6SE6400-3TD04-8DD0 D 290 240 240 125 190 26.0
(11.42) (9.45) (9.45) (4.92) (7.48)
6SE6400-3TD06-1DD0 D 345 300 220 120 240 34.0
(13.58) (11.81) (8.66) (4.72) (9.45)
a
MICROMASTER 430
Dimension drawings
■ Sinusoidal filter
G_DA51_XX_00013
a
n1
c
n2 n3 n4
Sinusoidal filter for frame sizes FX and GX
b
G_DA51_XX_00014
a
3
n1
c
n2 n3 n4
Sinusoidal filter for frame size GX
MICROMASTER 430
Dimension drawings
c b c b
G_DA51_XX_00064
a
a
d
e
DA51-5051
Line commu- Dimensions Weight Line commutating Dimensions Weight
tating choke (max.) choke for (max.)
for a b c d e kg a b c kg
Frame size C 245 185 50 264 280 5.1 Frame size D 520 275 85 9.5
(9.65) (7.28) (1.97) (10.39) (11.02) (20.47) (10.83) (3.35)
Frame size E 650 275 95 17.0
(25.59) (10.83) (3.74)
Line commutating choke for frame size C Line commutating choke for frame sizes D and E
b
c
G_DA51_XX_05052
choke (max.)
Type 6SE6400- Frame size a b c n1 n2 kg
3CC11-.... F 228 240 141 95 185 25.0
(8.98) (9.45) (5.55) (3.74) (7.28)
n1
n2
b
c
MICROMASTER 430
Dimension drawings
■ Output chokes
c b
G_DA51_XX_05050a
(max.)
a b c kg
Frame size C 245 185 80 6.6
(9.65) (7.28) (3.15)
b
Output for inverter Dimensions Weight
c
choke Frame size (max.)
Type (FS) a b c n1 n2 kg
6SE6400-
G_DA51_XX_05052
b
Output for inverter Dimensions Weight
c choke Frame size (max.)
Type (FS) a b c n1 n2 kg
6SL3000-
2BE32-1AA0 FX 285 300 257 163 224 60.0
(11.22) (11.81) (10.12) (6.42) (8.82)
G_DA51_XX_05053
Output chokes
for inverters of size FX and GX
Inverter
MICROMASTER 440
4/2 Description
4/12 Options
MICROMASTER 440
Description
MICROMASTER 440
Description
MICROMASTER 440
Circuit diagrams
PE
1/3 AC 200 - 240 V
3 AC 380 - 480 V
3 AC 500 - 640 V
SI
PE L/L1, N/L2,
+ 10 V
1 or
L/L1, N/L2, L3
0V
2 or
ADC1+ L1, L2, L3
≥ 4,7 k Ω AA/
3 BOP link
ADC1- DD
4
ADC2+ RS232
AA/
10 150.00
ADC2- DD
24 V external 11
BOP/AOP
DIN1 DIN1
5 5
DIN2 DIN2 ~
~
6 6
Opto isolation
DIN3 DIN3 ==
7 7
DIN4 DIN4 Frame sizes
8 8 A to F B+/DC+
DIN5 DIN5 DC-
R
16 16
DIN6 B-
DIN6
DC-
+ 17 17 Output +24 V
PNP
max. 100 mA
_ 24 V or 9 (isolated)
NPN Output 0 V
28 28 max. 100 mA
(isolated) Frame sizes Terminal
DCNA
PTCA FX and GX for
Motor A DCPA external
PTC/ 14 brake unit
PTCB D
KTY 84
15 CPU DCNS
Terminal
DAC1+ DCPS for
0 - 20 mA D dv/dt Filter
12
max. 500 DAC1- A
13 =
DAC2+
0 - 20 mA 26 D 3 ~
max. 500 DAC2- A
27
COM
20 NO Not 60 Hz
Relay 1 used 50 Hz
19 NC
1 2
4 18
COM
DIP switch
(on control board)
30 V DC/5 A (resistive load)
Relay 2 22 NO
250 V AC/2 A (inductive load)
21
ADC ADC
0 - 20 mA 1 2 DIP
COM current switch
25 NO 0 - 10 V on I/O
Relay 3 voltage board
24 1 2
NC
23
G_DA51_EN_05024h
P+
29 RS485 COM link
N-
30
PE U, V, W
CB automatic M
option
MICROMASTER 440
Circuit diagrams
Mains connections
View A
Motor connections
View A
AIN1 AIN2 RL1-A RL1-B RL1-C RL2-B RL2-C RL3-A RL3-B RL3-C
G_DA51_EN_05107
S1 S2
18 19 20 21 22 23 24 25
DIP Switches:
0 mA to 20 mA
or Output relay contacts
0 V to 10 V
12 13 14 18
15 16 17 26 27 28 29 30
NPN *)
1 2 3 4 5 6 7 8 9 10 11
PNP *)
MICROMASTER 440
Technical data
4 Relative humidity
Installation altitude 0.12 kW to 75 kW
95% (non-condensing)
up to 1000 m above sea level without derating
90 kW to 200 kW up to 2000 m above sea level without derating
Standard SCCR FSA, FSB, FSC: 10 kA
(Short Circuit Current Rating) 1) FSD, FSE, FSF, FSFX, FSGX: 42 kA
Protection features for Undervoltage, overvoltage, overload, earth faults, short-circuits, stall prevention, locked motor protection,
motor over-temperature, inverter overtemperature, parameter change protection
Compliance with standards u, cu, >, c-tick ● ✔
> marking Conformity with low-voltage directive 73/23/EEC
Cooling-air volumetric flow required, Frame size (FS) Cooling-air volumetric H xW x D, max. (mm) Weight, approx. (kg)
dimensions and weights flow required (l/s)/(CFM)
(without options) A 4.8/10.2 173 x 73 x 149 1.3
B 24/51 202 x 149 x 172 3.4
C 54.9/116.3 245 x 185 x 195 5.7
D 2 x 54.9/2 x 116.3 520 x 275 x 245 17
E 2 x 54.9/2 x 116.3 650 x 275 x 245 22
F without filter 150/317.79 850 x 350 x 320 56
F with filter 150/317.79 1150 x 350 x 320 75
FX 225/478.13 1400 x 326 x 356 116
GX 440/935 1533 x 326 x 545 174
1) For footnote, see page 4/7. CFM: Cubic Feet per Minute
MICROMASTER 440
Technical data
■ Derating data
Pulse frequency
MICROMASTER 440
Technical data
100 VT 1 0 0
Rated output current
R a te d o u tp u t c u rre n t
% CT 8 5
80 8 0
70 %
60 6 0
50
40 4 0
20 2 0
0 0
-10 0 10 20 30 40 50 60 °C 70 0 1 0 2 0 3 0 4 0 4 5 °C 5 5
Operating temperature O p e r a tin g te m p e r a tu r e
ADA51-5018c ADA51-5046
100 100
Rated output current
Rated output current
% 85
80 80
%
60 60
40 40
20 20
0 0
0 1000 2000 3000 m 4000 0 1000 2000 3000 m 4000
Operational altitude Operational altitude
100 100
Mains voltage
Mains voltage
% %
80 80
77 77
4 60
40
60
40
20 20
0 0
0 1000 2000 3000 m 4000 0 1000 2000 3000 m 4000
Operational altitude Operational altitude
MICROMASTER 440
MICROMASTER 440
MICROMASTER 440
MICROMASTER 440
Options
Variant dependent options
■ Overview
EMC filter, Class A With this filter, the inverter Leakage currents: Please note when using
complies with the emission LC filters/sinusoidal filters:
Filter for inverters without an The leakage currents of the in-
standard EN 55 011, Class B
internal filter for verters with/without filter (inter- • Only V/f, FCC control
for conducted interference
nal/external) may exceed permissible
• 3 AC 200 V to 240 V, emissions.
30 mA. Typical values in prac- • Please observe the derating
frame sizes A and B
tice are between 10 mA and of 15 % when selecting the
Additional EMC filter,
• 3 AC 380 V to 480 V, 50 mA. The exact values de- appropriate inverter
Class B
frame size A, FX, GX pend on the design, environ- • Operation only permissible
Available for inverters with an ment and cable lengths. Inter- with 4 kHz pulse frequency
Filters for frame sizes FX and
internal Class A EMC filter, ference-free operation with Note: Please observe derat-
GX are only permitted to be
frame sizes A, B and C. residual current operated de- ing for frame sizes FX and
used in combination with a line
vices with a trigger value of GX.
commutating choke. The requirements are fulfilled
30 mA cannot be guaranteed. • The output frequency is
using shielded cables with a
All other inverters with the ex- However, operation with resid- limited to 150 Hz
max. length of 25 m.
ception of inverters for 500 V ual current circuit-breakers • Operation and commission-
to 600 V can be supplied with With this filter, the inverter with a trigger value of 300 mA ing only with connected mo-
an internal Class A filter. complies with the emission is possible. Please refer to the tor as the LC filter/sinusoidal
standard EN 55 011, Class B Instruction Manual for details. filter is not idling-proof!
The requirements are fulfilled
for conducted interference
using shielded cables with a The LC filters/sinusoidal filters
emissions. LC filter and sinusoidal filter
max. length of 25 m. can be used for all MICRO-
The LC filter/sinusoidal filter MASTER 440 inverters of
Filter Class B with low
EMC filter, Class B limits the rate of rise of voltage frame sizes A to GX.
leakage currents
and the capacitive charge/
Filter for inverters without an • Frame sizes D to F:
EMC filter for 1 AC 200 V to discharge currents which usu-
internal filter for The LC filters, frame sizes D
240 V inverters, frame sizes A ally occur with inverter opera-
to F, are designed for
• 3 AC 200 V to 240 V, and B, without an internal EMC tion. This means that much
mounting upright in the con-
frame sizes A and B filter Class A. longer shielded motor cables
trol cabinet. Due to leakage
are possible when using LC fil-
• 3 AC 380 V to 480 V, With this filter, the inverter flux lines caused by physical
ters/sinusoidal filters and the
frame size A. complies with the emission sources, a minimum dis-
service life of the motor
standard EN 55 011, Class B tance of 50 mm to adjacent
The requirements are fulfilled achieves values similar to
for conducted interference modules and metal parts is
using shielded cables with a those with direct mains opera-
emissions. The leakage cur- recommended.
max. length of 25 m. tion. Use of an output choke
rents are reduced to
isn’t required with that. • Frame sizes FX and GX:
For inverters 15 kW to 75 kW < 3.5 mA.
The sinusoidal filters, frame
without filters, EMC filters of
The requirements are fulfilled sizes FX and GX, are de-
Class B from Schaffner can be
using shielded cables with a signed for mounting upright
used.
max. length of 5 m. in the control cabinet. Due to
The requirements are fulfilled leakage flux lines caused by
using shielded cables with a physical sources, a mini-
max. length of 25 m to 50 m mum distance of 100 mm to
(depending on the type, de- adjacent modules and metal
tails on request). parts is recommended.
■ Technical data
4 LC filter and sinusoidal filter
MICROMASTER 440
Options
Variant dependent options
MICROMASTER 440
Options
Variant dependent options
■ Overview
Line commutating choke For devices with 250 W and Output choke For MICROMASTER 440 in-
350 W, it is necessary either to verters of frame sizes FX and
Line commutating chokes are Output chokes can be sup-
fit the recommended input GX, external SIMOVERT
used to smooth voltage peaks plied for reducing the capaci-
chokes or to apply to the MASTERDRIVES brake units
or to bridge commutating tive compensation currents
power utility company for and the appropriate brake re-
dips. In addition, line commu- and dV/dt in the case of motor
authorization to connect the sistors can be used (see
tating chokes reduce the ef- cables >50 m (shielded) or
devices to the public power Catalog DA 65.10).
fects of harmonics on the in- >100 m (unshielded).
supply.
verter and the power supply. If Gland plate
No limits are currently defined For max. permissible cable
the line impedance is < 1 %, a
in the EN 61 000-3-2 standard lengths, see the Technical Gland plates are available for
line commutating choke must
for professionally used devic- Data. inverters of frame sizes A, B
be used in order to reduce the
es with a connected load and C. All the other frame siz-
current peaks. Brake resistors
>1 kW which means that the es have the shield connection
In line with EN 61 000-3-2 reg- inverters with an output power The brake resistors are de- for the control cable integrat-
ulations “Limits for harmonic ³ 0.75 kW comply with the signed for use with the ed in the inverter.
currents with device input cur- EN 61 000-3-2 standard. MICROMASTER 440 inverter
rent £16 A per phase”, there The shield for the power cable
However, in accordance with series, frame sizes A to F, with
are special aspects for drives has to be connected external-
the regulations of EN 61000-3- internal brake chopper and
with 250 W to 550 W and 230 V ly (e.g. in the control cabinet).
12 “Limits for harmonic cur- enable loads with a large mo-
single-phase supplies which Exception: Inverters of frame
rents > 16 A and £ 75 A per ment of inertia to be braked
can be used in non-industrial sizes D and E and frame size
phase” an approval is neces- quickly. During braking of the
applications (1st environ- F with integrated class A filter.
sary from the power supplier motor and the load, excess
ment). In this case the shield connec-
for drives that are intended to energy is fed back to the in-
tion is integrated in the invert-
be connected to the public verter. This causes the voltage
er.
low-voltage network. Please to rise in the DC link. The in-
refer to the Operating Instruc- verter transfers the excess en- The gland plate enables the
tions for the values of the har- ergy to the externally mounted shields of the power and con-
monic currents. braking resistor. trol cables to be terminated
ensuring optimum EMC per-
formance.
■ Technical data
Max. permissible cable Note:
lengths from the motor to
Operation up to 150 Hz output
the inverter when using
frequency only!
output chokes
The following table shows the
maximum permissible cable
lengths from the motor to the
inverter when using output
chokes.
Frame size Output choke Max. permissible motor cable lengths (shielded/unshielded)
for a mains voltage of
(FS) Type 200 V to 240 V ± 10 % 380 V to 400 V ± 10 % 401 V to 480 V ± 10 % 500 V to 600 V ± 10 %
A 6SE6400-3TC00-4AD3 200 m/300 m – – –
4 A
B
6SE6400-3TC00-4AD2
6SE6400-3TC01-0BD3
–
200 m/300 m
150 m/225 m
150 m/225 m
100 m/150 m
100 m/150 m
–
–
C 6SE6400-3TC03-2CD3 200 m/300 m 200 m/300 m 100 m/150 m –
C 6SE6400-3TC01-8CE3 – – – 100 m/150 m
D to F 6SE6400-3TC. .-. . . . 200 m/300 m 200 m/300 m 200 m/300 m 200 m/300 m
FX 6SL3000-2BE32-1AA0 – 300 m/450 m 300 m/450 m –
FX 6SL3000-2BE32-6AA0 – 300 m/450 m 300 m/450 m –
GX 6SL3000-2BE33-2AA0 – 300 m/450 m 300 m/450 m –
GX 6SL3000-2BE33-8AA0 – 300 m/450 m 300 m/450 m –
GX 6SL3000-2BE35-0AA0 – 300 m/450 m 300 m/450 m –
MICROMASTER 440
Options
Variant dependent options
■ Design
General installation instructions
■ A maximum of two footprint ■ The EMC filter must be
components plus inverter mounted directly below the
are permissible. frequency inverter if pos-
■ If an LC filter is used, it sible.
must, if possible, be moun- ■ If mounted on the side, the
ted directly on the wall of line-side components are to
the control cabinet due to be mounted to the left of the
G_DA51_EN_05016d
weight reasons. frequency inverter whereas
If an LC filter of frame size C the output-side compon-
is used, therefore, only one ents are to be mounted to
footprint component is per- the right of the frequency in-
Position 2
missible. If a line choke and verter.
LC filter are used, the line ■ If a braking resistor is used,
choke must be located on it must, if possible, be
the left of the inverter. mounted directly on the
Required distance between wall of the control cabinet Position 1
line choke and inverter: due to reasons relating to
75 mm. temperature increases.
Frame size
A B C D E F G FX GX
Line commutating choke ✓ ✓ ✓ ✓ ✓
EMC filter ✓ ✓ ✓
LC filter ✓ ✓ ✓
Output choke ✓ ✓ ✓
Braking resistor ✓ ✓
MICROMASTER 440
Options
Variant dependent options
MICROMASTER 440
Options
Variant dependent options
MICROMASTER 440
Options
Variant dependent options
MICROMASTER 440
Options
Variant dependent options
3 AC 380 V
5.5
2.2
7.5
3.0
6SE6440-2AC25-5CA1
6SE6440-2AD22-2BA1 6SE6400-3TC01-0BD3 6SE6400-4BD12-0BA0 6SE6400-0GP00-0BA0 4
to 480 V 3.0 4.0 6SE6440-2AD23-0BA1
4.0 5.0 6SE6440-2AD24-0BA1
5.5 7.5 6SE6440-2AD25-5CA1 6SE6400-3TC03-2CD3 6SE6400-4BD16-5CA0 6SE6400-0GP00-0CA0
7.5 10 6SE6440-2AD27-5CA1
11.0 15 6SE6440-2AD31-1CA1
15.0 20 6SE6440-2AD31-5DA1 6SE6400-3TC05-4DD0 6SE6400-4BD21-2DA0 Integrated as standard
18.5 25 6SE6440-2AD31-8DA1 6SE6400-3TC03-8DD0 for shield connection of
the control cable and
22 30 6SE6440-2AD32-2DA1 6SE6400-3TC05-4DD0 the power cable.
30 40 6SE6440-2AD33-0EA1 6SE6400-3TC08-0ED0 6SE6400-4BD22-2EA0
37 50 6SE6440-2AD33-7EA1 6SE6400-3TC07-5ED0
45 60 6SE6440-2AD34-5FA1 6SE6400-3TC14-5FD0 6SE6400-4BD24-0FA0
55 75 6SE6440-2AD35-5FA1 6SE6400-3TC15-4FD0
75 100 6SE6440-2AD37-5FA1 6SE6400-3TC14-5FD0
MICROMASTER 440
Options
Variant dependent options
MICROMASTER 440
Options
Variant independent options
■ Overview
Basic Operator Panel (BOP) The AOP is directly plugged PROFIBUS module CANopen module
into the inverter, or communi-
With the BOP, individual pa- For a complete PROFIBUS Using the CANopen commu-
cates with the latter through a
rameter settings can be made. connection with up to nications module, an inverter
door mounting kit. Together
Values and units are shown on £ 12 Mbaud. Remote control can be linked to the CANopen
with the “AOP door mounting
a 5-digit display. of the inverter is possible with fieldbus system and remote
kit for multiple inverters”, the
the PROFIBUS module. Re- control is then possible.
AOP permits bus communica-
mote control and operation at
tion with up to 30 inverters at a Remote control and operation
the inverter can be combined
transmission rate of 38 kbaud. at the inverter can be com-
using an operator panel
(RS485, USS). bined using an operator panel
plugged onto the PROFIBUS
plugged onto the CANopen
For servicing purposes, the module. The PROFIBUS mod-
module.
AOP furthermore supports the ule can be supplied by an ex-
download and upread of com- ternal 24 V DC power supply The module is connected to
plete parameter kits. and is thus also active when the bus system through a
the inverter is disconnected 9-pin Sub-D connector.
Asian Advanced from the power supply.
Operator Panel (AAOP) Pulse encoder evaluation
Connection by means of a
module
The AAOP is the Chinese ver- 9-pin Sub-D connector (avail-
Basic Operator Panel (BOP) sion of the AOP operator pan- able as an option). The pulse encoder evaluation
el. It has an enhanced display module permits direct con-
A BOP can be used for several
and supports the operating DeviceNet module nection of the most widely en-
inverters. It can be directly
languages of Chinese (simpli- countered digital pulse en-
mounted on the inverter or in a For networking the inverters to
fied) and English. coders to the inverter.
control cabinet door using a the DeviceNet fieldbus system
mounting kit. widely used on the American They offer the following func-
market. A maximum transmis- tions:
Advanced Operator Panel sion rate of 500 kbaud is pos- ■ Zero speed at full load
(AOP) sible. Remote control of the in- torque
verter is possible with the De- ■ Extremely accurate speed
The AOP enables
viceNet module. Remote con- control
MICROMASTER 440 parame-
trol and operation at the invert-
ter kits to be easily read and ■ Increased dynamic re-
er can be combined using an
modified. In contrast to the sponse of speed and
operator panel plugged onto
BOP, the value and meaning torque control.
the DeviceNet module.
of the parameters can be di-
rectly displayed as plain text The connection to the This module can be used with
in several languages by fast DeviceNet bus system is HTL and TTL pulse encoders
scrolling of the address. made using a 5-pin connector (High voltage Transistor
Asian Advanced Operator Panel with terminal strip. Logic, 24 V and Transistor
(AAOP) Logic, 5 V).
Cyrillic Advanced
Operator Panel (CAOP)
The CAOP is the Cyrillic ver-
sion of the AOP Advanced
Operator Panel. It supports
the Cyrillic, German and
English operator languages.
4
Advanced Operator Panel (AOP)
MICROMASTER 440
Options
Variant independent options
■ Overview (continued)
Connection kit for Connection kit for PC AOP door mounting kit for Start-up tools
PC to inverter to AOP multiple inverters (USS)
• STARTER
For controlling an inverter di- For connecting a PC to an For mounting an AOP or AAOP Starter is graphic start-up
rectly from a PC if the appro- AOP or AAOP. Offline pro- in a control cabinet door. software for guided start-up
priate software has been in- gramming of inverters and Degree of protection IP56. for MICROMASTER 410/
stalled (e.g. STARTER). Isolat- archiving of parameter kits The AOP or AAOP can com- 420/430/440 frequency in-
ed RS-232 adapter module for possible. Includes a desktop municate with several invert- verters under Windows
reliable point-to-point connec- attachment kit for an AOP or ers by means of the RS-485 2000/XP Professional. Pa-
tion to a PC. Includes a Sub-D AAOP, an RS-232 standard USS protocol. The 4-pin con- rameter lists can be read
connector and an RS-232 cable (3 m) with Sub-D con- necting cable from the AOP or out, altered, stored, entered
standard cable (3 m). nectors and a universal power AAOP to the RS-485 terminals and printed.
supply unit. of the inverter and to the 24 V
• DriveMonitor
user terminal strip is not in-
is a start-up software for list-
Operator panel door mount- cluded 2).
oriented programming of
ing kit for single inverter
frequency inverters. This
For mounting an operator program executes under
panel in a control cabinet Windows 98/NT/2000/ME/
door. Degree of protection XP Professional.
IP56. Contains a cable
Both programs are included
adapter module with screw-
on the Docu DVD which is pro-
less terminals for use with
vided with every inverter.
user's own RS-232 cables 1).
MICROMASTER 440
Options
Variant independent options
■ Technical data
PROFIBUS module DeviceNet module
6SE6400-1PB00-0AA0 6SE6400-1DN00-0AA0
MICROMASTER 440
Options
Variant independent options
MICROMASTER 440
Documentation
1) The DVD contains operating Available on the Internet: STARTER at 2) Available on the Internet at
instructions, parameter list, DriveMonitor at http://support.automation. http://support.automation.
commissioning tools STARTER http://support.automation. siemens.com/WW/view/en/ siemens.com/WW/view/en/
and DriveMonitor, multilan- siemens.com/WW/view/en/ 10804985/133100 10804926/133300
guage. 10804984/133100
MICROMASTER 440
Dimension drawings
(2.28)
58
173 (6.81)
160 (6.29)
DIN Rail
ADA51-5000e
ADA51-5007c
147 (5.79)
195 (7.68)
Fixing with 2 x M4 bolts, 2 x M4 nuts,
2 x M4 washers
(5 149
Drill pattern
174 (6.85)
G_DA51_EN_05001d
ADA51-5008b
202 (7.95)
258 (10.16)
138 (5.43)
(6 172
4 x M4 washers
149 (5.87)
Tightening torque with washers fitted:
Inverter frame size B 2.5 Nm Inverter frame size B with gland plate
Ventilation clearance required
Top and bottom: 100 mm
Drill pattern
204 (8.03)
4
ADA51-5009b
245 (9.65)
309 (12.16)
ADA51-5002d
174 (6.85)
Fixing with 4 x M5 bolts, 4 x M5 nuts,
(7 195
8)
4 x M5 washers
.6
MICROMASTER 440
Dimension drawings
Drill pattern
616.4 (24.27)
650 (25.59)
520 (20.47)
486 (19.13)
ADA51-5020b
ADA51-5021b
(9 245
(9 245
5)
5)
.6
Fixing with Fixing with
.6
Drill pattern
1110 (43.70)
1150 (45.28)
850 (33.46)
810 (31.89)
4
ADA51-5023b
ADA51-5022b
(1 320
6)
6)
2.
MICROMASTER 440
Dimension drawings
Drill pattern
Drill pattern
125 125
(4.92) (4.92)
125 125
(4.92) (4.92)
1508 (59.37)
1533 (60.35)
1375 (54.13)
1400 (55.12)
G_DA51_EN_05074
G_DA51_EN_05075
125 125
125 125 (4.92) (4.92)
1. 5
(4.92) (4.92)
)
46
(2 54
4. 6
)
06
(1 35
Fixing with
326 Fixing with 326 6 x M8 bolts
(12.83) 6 x M8 bolts (12.83) 6 x M8 nuts
6 x M8 nuts 6 x M8 washers
Inverter frame size FX 6 x M8 washers Inverter frame size GX
Tightening torque
Tightening torque with washers
with washers fitted: 13.0 Nm
fitted: 13.0 Nm Ventilation clearance
Ventilation clearance required:
required: at top: 250 mm
at top: 250 mm at bottom: 150 mm
at bottom: 150 mm in front: 50 mm
in front: 40 mm
MICROMASTER 440
Dimension drawings
■ EMC filter
38 185 (7.28)
(1.5) 156 (6.14)
24 149 (5.87)
73 (2.87)
(0.94) 120 (4.72)
56 (2.2)
4 x M4
4 x M4
219 (8.62)
232 (9.13)
2 x M4
187 (7.36)
200 (7.87)
245 (9.65)
204 (8.03)
174 (6.85)
187 (7.36)
213 (8.39)
174 (6.85)
200 (7.87)
160 (6.3)
G_DA51_EN_00061
G_DA51_EN_00062
G_DA51_EN_00063
43.5 (1.71) 50.5 (1.99) 55 (2.17)
138 174
(5.43) (6.85)
EMC filter for frame size A For frame size B For frame size C
b1
n4
b
c
n3
a
a1
G_DA51_XX_05103
MICROMASTER 440
Dimension drawings
■ LC filter
280 (11.02)
287 (11.3)
293 (11.53)
300 (11.81)
340 (13.38)
334 (13.15)
G_DA51_EN_05080
G_DA51_EN_05077
G_DA51_EN_05079
G_DA51_EN_05076
56 120
(2.2) (4.72)
174 (6.85)
320 (12.6)
335 (13.19)
382 (15.04)
G_DA51_EN_05078a
G_DA51_EN_05081
156 (6.14)
MICROMASTER 440
Dimension drawings
■ LC filter
b
LC filter for inverter Dimensions Weight,
c Type Frame size approx
G_DA51_XX_05082
(FS)
a b c n1 n2 kg
6SE6400-3TD03-7DD0 D 278 240 230 115 190 21.0
(10.94) (9.45) (9.06) (4.53) (7.48)
6SE6400-3TD04-8DD0 D 290 240 240 125 190 26.0
(11.42) (9.45) (9.45) (4.92) (7.48)
6SE6400-3TD06-1DD0 D 345 300 220 120 240 34.0
(13.58) (11.81) (8.66) (4.72) (9.45)
a
MICROMASTER 440
Dimension drawings
■ Sinusoidal filter
G_DA51_XX_00013
a
n1
c
n2 n3 n4
Sinusoidal filter for frame sizes FX and GX
b
G_DA51_XX_00014
a
n1
c
n2 n3 n4
Sinusoidal filter for frame size GX
MICROMASTER 440
Dimension drawings
G_DA51_XX_00064
(8.39) (5.91) (1.97) (8.66) (9.17)
a
DA51-5013e
d
e
Frame size C 245 185 50 264 280 5.1
(380–480 V) (9.65) (7.28) (1.97) (10.39) (11.02)
Frame size C 245 185 50 264 280 3.8
(500–600 V, (9.65) (7.28) (1.97) (10.39) (11.02)
0.75–1.5 kW)
Frame size C 245 185 50 264 280 4.0
(500–600 V, (9.65) (7.28) (1.97) (10.39) (11.02)
2.2–4 kW)
Frame size C 245 185 80 264 280 8.0
Line commutating choke For frame sizes B and C (500–600 V, (9.65) (7.28) (3.15) (10.39) (11.02)
for frame size A 5.5–11 kW)
c b
DA51-5051
MICROMASTER 440
Dimension drawings
■ Output chokes
c b
c b
G_DA51_XX_05050a
3TC00-4AD2 200 75.5 110 1.9
(7.87) (2.97) (4.33)
a
a
DA51-5049
Output choke
for frame size A For frame sizes B and C
6SE6400-3TC00-4AD2 6SE6400-3TC01-0BD3
6SE6400-3TC00-4AD3 6SE6400-3TC01-8CE3
6SE6400-3TC03-2CD3
Output chokes
for inverters of frame sizes FX and GX
All dimensions in mm (values in brackets are in inches)
MICROMASTER 440
Dimension drawings
■ Brake resistors
Fig. 1: Fig. 2: Fig. 3: n4
b
b c b
c
n4 n4
n3
DA51-5056
a
n3
a
n3
a
DA51-5055a
DA51-5069
n1 c0
c1
n2
4BD21-2DA0 27 D 3
(11.22)
515
(7.28)
270
(5.91)
175
(7.28)
210
(8.54)
242
(6.69)
195
(5.71)
205
(7.87)
350
(9.06)
315 7.4 4
(20.28) (10.63) (6.89) (8.27) (9.53) (7.68) (8.07) (13.78) (12.40)
4BD22-2EA0 15 E 3 645 270 175 210 242 195 205 480 315 10.6
(25.39) (10.63) (6.89) (8.27) (9.53) (7.68) (8.07) (18.90) (12.40)
4BD24-0FA0 8.2 F 3 650 395 315 350 382 335 270 510 435 16.7
(25.59) (15.55) (12.40) (13.78) (15.04) (13.19) (10.63) (20.08) (17.13)
4BE14-5CA0 120 C 3 285 185 150 185 217 170 145 200 230 3.8
(11.22) (7.28) (5.91) (7.28) (8.54) (6.69) (5.71) (7.87) (9.06)
4BE16-5CA0 82 C 3 285 185 150 185 217 170 145 200 230 3.8
(11.22) (7.28) (5.91) (7.28) (8.54) (6.69) (5.71) (7.87) (9.06)
4BE21-3DA0 39 D 3 515 270 175 210 242 195 205 350 315 7.4
(20.28) (10.63) (6.89) (8.27) (9.53) (7.68) (8.07) (13.78) (12.40)
4BE21-8EA0 27 E 3 645 270 175 210 242 195 205 480 315 10.6
(25.39) (10.63) (6.89) (8.27) (9.53) (7.68) (8.07) (18.90) (12.40)
4BE24-2FA0 12 F 3 650 395 315 350 382 335 270 510 435 16.7
(25.59) (15.55) (12.40) (13.78) (15.04) (13.19) (10.63) (20.08) (17.13)
Brake resistors for inverters of frame sizes A to F All dimensions in mm (values in brackets are in inches)
MICROMASTER 440
Notes
MICROMASTER
420/430/440
Appendix
A/2 Environment, resources and recycling
A/2 Certificates
MICROMASTER 420/430/440
Appendix
■ Certificates
MICROMASTER 420/430/440
Appendix
■ Certificates (continued)
Legend for EC declaration of conformity:
A
1) Deviations to the requirements listed in EN 61800-5-1 must be
documented in a technical report on the risk assessment.
MICROMASTER 420/430/440
Appendix
MICROMASTER 420/430/440
Appendix
Electromagnetic No inadmissible electromag- The table below lists the The inverters were installed
compatibility netic emissions occur if the in- results of measurements with shielded motor cables
stallation instructions specific relating to the emissions and and shielded control cables in
to the product are correctly immunity to interference of accordance with the direc-
observed. MICROMASTER inverters. tives.
EMC phenomenon Relevant criteria Limit value
Standard/test
Emitted interference Conducted via mains cable 150 kHz to 30 MHz Unfiltered devices, not tested.
EN 61 800-3 All devices with an internal/external filter:
Depending on the type of filter and on the envisaged
PDS installation:
Category C1:
Limit value complies with EN 55 011, Class B
Category C2:
Limit value complies with EN 55 011, Class A, Group 1.
In addition, all devices with an internal/external filter
comply with the limit value for category C3 installations.
Limit value complies with EN 55 011, Class A, Group 2.
Emitted by the drive 30 MHz to 1 GHz All devices.
Limit value complies with EN 55 011, Class A, Group 1.
ESD immunity ESD through air discharge Test severity level 3 8 kV
EN 61 000-4-2 ESD through contact discharge Test severity level 3 6 kV
Immunity to electrical Electrical field applied to unit Test severity level 3 10 V/m
fields 80 MHz to 1 GHz
EN 61 000-4-3
Immunity to burst Applied to all cable Test severity level 4 4 kV
interference terminations
EN 61 000-4-4
Surge immunity Applied to mains cables Test severity level 3 2 kV
EN 61 000-4-5
Immunity to RFI Applied to mains, motor and Test severity level 3 10 V
emissions, conducted control cables 0.15 MHz to 80 MHz
EN 61 000-4-6 80 % AM (1 kHz)
MICROMASTER 420/430/440
Appendix
MICROMASTER 420/430/440
Appendix
■ Demonstration case
SIDEMO demonstration case system
The SIDEMO range of modular The demonstration systems
demonstration case systems are fitted in dark blue transport
also includes cases for the cases (400 x 300 x 210 mm).
MICROMASTER inverters. The transport cases can be
stacked.
The MICROMASTER demon-
stration cases can be operat- If the MICROMASTER 420/440
ed on 230 V supplies on their demonstration case is ex-
own or together with other panded with a PROFIBUS
demonstration systems such module (not included in scope
as LOGO!, SIMATIC S7-200, of supply of the case), it is also
SITOP DC-UPS. possible to demonstrate incor-
poration into TIA in combina-
tion with the SIMATIC S7-300
Compact and Touchpanel
TP170B demonstration sys-
tems.
MICROMASTER 420/430/440
Appendix
Wide variety
With a total of about 300 local attendance courses, we train the
complete range of A&D products as well as interaction of the
products in systems. Telecourses, teach-yourself software and
seminars with a presenter on the Web supplement our classic
range of courses.
Tailor-made training
We are only a short distance away. You can find us at more than
50 locations in Germany, and in 62 countries worldwide. You
wish to have individual training instead of one of our
300 courses? Our solution: We will provide a program tailored
exactly to your personal requirements. Training can be carried
out in our Training Centers or at your company.
First-class know-how directly pays for itself: In shorter
startup times, high-quality end products, faster trouble- The right mixture: Blended learning
shooting and reduced downtimes. In other words, increased “Blended learning” means a combination of various training me-
profits and lower costs. dia and sequences. For example, a local attendance course in
a Training Center can be optimally supplemented by a teach-
Achieve more with SITRAIN yourself program as preparation or follow-up. Additional effect:
• Shorter times for startup, maintenance and servicing Reduced traveling costs and periods of absence.
• Optimized production operations
• Reliable configuration and startup
• Minimization of plant downtimes
• Flexible plant adaptation to market requirements
• Compliance with quality standards in production
• Increased employee satisfaction and motivation
• Shorter familiarization times following changes in technology
and staff
■ Contact
Visit our site on the Internet at:
www.siemens.com/sitrain
or let us advise you personally. You can request our latest train-
ing catalog from:
MICROMASTER 420/430/440
Appendix
A
SIMATIC ET 200S FC SIMATIC ET 200S FC
Control Units Power Modules
MICROMASTER 420/430/440
Appendix
A
SIMATIC ET 200pro FC SIMATIC ET 200pro FC Failsafe
Standard frequency inverter Frequency inverter with integrated safety functions
MICROMASTER 420/430/440
Appendix
A
SINAMICS G110 inverter chassis units
MICROMASTER 420/430/440
Appendix
MICROMASTER 420/430/440
Appendix
MICROMASTER 420/430/440
Appendix
Type of construction All common types of construction All common types of construction All common types of construction
Speed 750 ... 3000 rpm 750 ... 3000 rpm 1000 ... 3000 rpm
Rated torque 0.3 ... 292 Nm 9.9 ... 10300 Nm 2.5 ... 1546 Nm
Rated voltages All commonly used voltages All commonly used voltages 230VD/400 VY,
500 VD,
400VD/690 VY,
500 VY
Designation EFF1, EFF2 EFF1, EFF2 EFF1, EFF2
Approvals for marine propulsion Below deck use: Below deck use: No
drives BV, DNV, GL, LR BV, DNV, GL, LR
Explosion protection Ex nA II T3 (Zone 2), Ex nA II T3 (Zone 2), No
(incl. temp. class) Dust-ex (Zone 21, 22) Dust-ex (Zone 21, 22)
MICROMASTER 420/430/440
Appendix
MICROMASTER 420/430/440
Appendix
MICROMASTER 420/430/440
Appendix
■ Overview of distributed drive solutions – MICROMASTER 411 and COMBIMASTER 411 inverters
The MICROMASTER 411 and view of the features of these ed in the Catalog DA 51.3 COMBIMASTER 411 is avail-
COMBIMASTER 411 inverters products. The complete range MICROMASTER 411 and able in the Internet under:
from Siemens are available as of products together with COMBIMASTER 411. http://www.siemens.com/
distributed drive solutions. ordering data, technical data The latest information on combimaster
The table provides an over- and explanations are indicat- MICROMASTER 411 and
MICROMASTER 420/430/440
Appendix
Example of NEMA motor, Severe Duty SD100, cast-iron case Example of NEMA motor, General Purpose GP10A, aluminium case
MICROMASTER 420/430/440
Appendix
MICROMASTER 420/430/440
Appendix
MICROMASTER 420/430/440
Appendix
■ Technical consulting
Support in the planning and designing of your project from de-
tailed actual-state analysis, target definition and consulting on
product and system questions right to the creation of the auto-
mation solution. 1)
■ Service on site
With service on site we offer
I services for startup and mainte-
In the face of harsh competition you need optimum conditions to nance, essential for ensuring
keep ahead all the time: system availability.
a strong starting position, a sophisticated strategy and team for In Germany
the necessary support – in every phase. Phone: +49 (0)180 50 50 444 1)
Service & Support from Siemens provides this support with a (0.14 €/min. from the German
complete range of different services for automation and drives. fixed network)
In every phase: from planning and commissioning to mainte- In the United States, call
nance and upgrading. toll-free:
Phone: +1 800 333 7421
Our specialists know when and where to act to keep the produc-
tivity and cost-effectiveness of your system running in top form. In Canada, call:
Phone: +1 888 303 3353
■ Online support
The comprehensive information ■ Repairs and spare parts
system available round the In the operating phase of a ma-
clock via Internet ranging from chine or automation system we
Product Support and Service & provide a comprehensive repair
Support services to Support and spare parts service ensu-
Tools in the Shop. ring the highest degree of ope-
http://www.siemens.com/ rating safety and reliability.
automation/service&support In Germany
Phone: +49 (0)180 50 50 448 1)
(0.14 €/min. from the German
fixed network)
■ Technical support In the United States, call
Competent consulting in techni- toll-free:
cal questions covering a wide Phone: +1 800 241 4453
range of customer-oriented ser- In Canada, call:
vices for all our products and Phone: +1 888 303 3353
systems.
Phone: +49 (0)180 50 50 222 ■ Optimization and upgrading
Fax: +49 (0)180 50 50 223 To enhance productivity and
(0.14 €/min. from the German save costs in your project we
fixed network) offer high-quality services in
E-Mail: optimization and upgrading. 1)
adsupport@siemens.com
MICROMASTER 420/430/440
Appendix
■ Subject index
MICROMASTER MICROMASTER
A L
LC filter - 2/13 3/14 4/17
Line commutating chokes
(option) - 2/13 3/14 4/16
MICROMASTER 420/430/440
Appendix
MICROMASTER 420/430/440
Appendix
■ Terms and Conditions of Sale and Delivery An exact explanation of the metal factor and the text of the
Comprehensive Terms and Conditions of Sale and Delivery are
By using this catalog you can acquire hardware and software available free of charge from your local Siemens business office
products described therein from Siemens AG subject to the fol- under the following Order Nos.:
lowing terms. Please note! The scope, the quality and the condi-
tions for supplies and services, including software products, by • 6ZB5310-0KR30-0BA1
any Siemens entity having a registered office outside of Ger- (for customers based in Germany)
many, shall be subject exclusively to the General Terms and • 6ZB5310-0KS53-0BA1
Conditions of the respective Siemens entity. The following terms (for customers based outside Germany)
apply exclusively for orders placed with Siemens AG.
or download them from the Internet
For customers with a seat or registered office in Germany http://www.siemens.com/automation/mall
The “General Terms of Payment” as well as the “General Condi- (Germany: A&D Mall Online-Help System)
tions for the Supply of Products and Services of the Electrical
and Electronics Industry” shall apply.
For software products, the “General License Conditions for Soft- ■ Export regulations
ware Products for Automation and Drives for Customers with a The products listed in this catalog may be subject to European /
Seat or registered Office in Germany” shall apply. German and/or US export regulations.
For customers with a seat or registered office outside of Therefore, any export requiring a license is subject to approval
Germany by the competent authorities.
The “General Terms of Payment” as well as the “General Condi- According to current provisions, the following export regulations
tions for Supplies of Siemens, Automation and Drives for Cus- must be observed with respect to the products featured in this
tomers with a Seat or registered Office outside of Germany” shall catalog:
apply.
For software products, the “General License Conditions for Soft- AL Number of the German Export List
ware Products for Automation and Drives for Customers with a
Seat or registered Office outside of Germany” shall apply. Products marked other than “N” require an export
license.
General In the case of software products, the export des-
The dimensions are in mm. In Germany, according to the Ger- ignations of the relevant data medium must also
man law on units in measuring technology, data in inches only be generally adhered to.
apply to devices for export. Goods labeled with an “AL“ not equal to “N” are
Illustrations are not binding. subject to a European or German export authori-
zation when being exported out of the EU.
Insofar as there are no remarks on the corresponding pages,
- especially with regard to data, dimensions and weights given - ECCN Export Control Classification Number
these are subject to change without prior notice. Products marked other than “N” are subject to a
The prices are in € (Euro) ex works, exclusive packaging. reexport license to specific countries.
The sales tax (value added tax) is not included in the prices. In the case of software products, the export
It shall be debited separately at the respective rate according to designations of the relevant data medium must
the applicable legal regulations. also be generally adhered to.
Prices are subject to change without prior notice. We will debit Goods labeled with an “ECCN“ not equal to “N”
the prices valid at the time of delivery. are subject to a US re-export authorization.
Surcharges will be added to the prices of products that contain
silver, copper, aluminum, lead and/or gold if the respective basic Even without a label or with an “AL: N” or “ECCN: N”, authoriza-
official prices for these metals are exceeded. These surcharges tion may be required due to the final destination and purpose for
will be determined based on the official price and the metal fac- which the goods are to be used.
tor of the respective product. The deciding factors are the AL or ECCN export authorization
The surcharge will be calculated on the basis of the official price indicated on order confirmations, delivery notes and invoices.
on the day prior to receipt of the order or prior to the release Errors excepted and subject to change without prior notice.
order.
The metal factor determines the official price as of which the A&D/VuL_ohne MZ/En 05.09.06
metal surcharges are charged and the calculation method used.
The metal factor, provided it is relevant, is included with the price
information of the respective products.
Catalogs of the
Automation and Drives Group (A&D)
Further information can be obtained from our branch offices listed
in the appendix or at www.siemens.com/automation/partner
Automation and Drives Catalog Industrial Communication for Catalog
Interactive catalog on CD-ROM and on DVD Automation and Drives IK PI
• The Offline Mall of Automation and Drives CA 01
Low-Voltage
Automation Systems for Machine Tools
Controls and Distribution – LV 1
SINUMERIK & SIMODRIVE NC 60 SIRIUS, SENTRON, SIVACON
SINUMERIK & SINAMICS NC 61 Controls and Distribution – LV 1 T
Technical Information
Drive Systems SIRIUS, SENTRON, SIVACON
Variable-Speed Drives SIDAC Reactors and Filters LV 60
SINAMICS G110/SINAMICS G120 D 11.1 SIVENT Fans LV 65
Inverter Chassis Units SIVACON 8PS Busbar Trunking Systems LV 70
SINAMICS G120D
Distributed Frequency Inverters
SINAMICS G130 Drive Converter Chassis Units, D 11 Motion Control System SIMOTION PM 10
SINAMICS G150 Drive Converter Cabinet Units
SINAMICS GM150/SINAMICS SM150 D 12
Medium-Voltage Converters Process Instrumentation and Analytics
SINAMICS S120 Drive Converter Systems D 21.1 Field Instruments for Process Automation FI 01
SINAMICS S150 Drive Converter Cabinet Units D 21.3 Measuring Instruments for Pressure,
Differential Pressure, Flow, Level and Temperature,
Asynchronous Motors Standardline D 86.1 Positioners and Liquid Meters
Synchronous Motors with Permanent-Magnet D 86.2 PDF: Indicators for panel mounting MP 12
Technology, HT-direct
SIREC Recorders and Accessories MP 20
DC Motors DA 12
SIPART, Controllers and Software MP 31
SIMOREG DC MASTER 6RA70 Digital Chassis DA 21.1
Converters SIWAREX Weighing Systems WT 01
SIMOREG K 6RA22 Analog Chassis Converters DA 21.2 Continuous Weighing and Process Protection WT 02
SIMOREG DC MASTER 6RM70 Digital Converter DA 22 Process Analytical Instruments PA 01
Cabinet Units PDF: Process Analytics, PA 11
SIMOVERT PM Modular Converter Systems DA 45 Components for the System Integration
SIEMOSYN Motors DA 48
MICROMASTER 410/420/430/440 Inverters DA 51.2 SIMATIC Industrial Automation Systems
MICROMASTER 411/COMBIMASTER 411 DA 51.3 SIMATIC PCS Process Control System ST 45
SIMOVERT MASTERDRIVES Vector Control DA 65.10 Products for Totally Integrated Automation and ST 70
SIMOVERT MASTERDRIVES Motion Control DA 65.11 Micro Automation
Synchronous and asynchronous servomotors for DA 65.3 SIMATIC PCS 7 Process Control System ST PCS 7
SIMOVERT MASTERDRIVES Add-ons for the SIMATIC PCS 7 ST PCS 7.1
SIMODRIVE 611 universal and POSMO DA 65.4 Process Control System
Low-Voltage Three-Phase-Motors Migration solutions with the SIMATIC PCS 7 ST PCS 7.2
Process Control System
IEC Squirrel-Cage Motors D 81.1
pc-based Automation ST PC
Automation Systems for Machine Tools SIMODRIVE NC 60
SIMATIC Control Systems ST DA
• Main Spindle/Feed Motors
• Converter Systems SIMODRIVE 611/POSMO
Automation Systems for Machine Tools SINAMICS NC 61 SIMATIC Sensors
• Main Spindle/Feed Motors Sensors for Factory Automation FS 10
• Drive System SINAMICS S120
Drive and Control Components for Hoisting Equipment HE 1 Systems Engineering
Power supplies SITOP power KT 10.1
Electrical Installation Technology System cabling SIMATIC TOP connect KT 10.2
PDF: ALPHA Small Distribution Boards and ET A1
Distribution Boards, Terminal Blocks
PDF: ALPHA 8HP Molded-Plastic Distribution System ET A3 System Solutions
PDF: BETA Low-Voltage Circuit Protection ET B1 Applications and Products for Industry are part of the
interactive catalog CA 01
PDF: DELTA Switches and Socket Outlets ET D1
GAMMA Building Controls ET G1
TELEPERM M Process Control System
Human Machine Interface Systems SIMATIC HMI ST 80 PDF: AS 488/TM automation systems PLT 112
Subject to change without notice | Dispo 18404 | KG 1007 30.0 E 116 En / 722348 | Printed in Germany | © Siemens AG 2007
www.siemens.com/micromaster