Manual - Sumoheat 1050 .Compressed PDF
Manual - Sumoheat 1050 .Compressed PDF
MOBILEHEATINGAPPARATUS.
2
3
13
20
26
4
26
5
Front part
Compartment lid
of the tank
Control panel
Burner
Window of
inspection
Supply grid
of hot air
Base
Back part:
Orifice of
drainage
Hot air intake
22
Air filter
Electric cable
Plug
AC220V/50Hz only
6
Control panels for FH-1030
ABSORPTION PILOT SCHEDULED PILOT
COLOR For the TIMER hour programming, the pilot is
The pilot light turns on: 13 14 green: the Timer function is in standby mode.
the function of
odor absorption is activated with the 17
on or to extinction
TIMING BUTTON
Se utiliza para programar el
desired combustion period TEMPERATURE SELECTION BUTTON
after the automatic ignition It is used to program the desired temperature.
of the device with Timer mode. + for a higher temperature
for a lower temperature
17 15
7
Control panels for FH-1050
ABSORPTION PILOT
COLOR SCHEDULE PILOT
13 14 For the TIMER hour programming, the pilot is
The pilot turns on:
green: the Timer function is in standby position.
the function of
odor absorption is activated with the
on or to the extinction. 17
TIMING BUTTON
It is used to program the
desired combustion period TEMPERATURE SELECTION BUTTON
after the automatic ignition It is used to set the desired temperature.
of the device with Timer mode. + for a higher temperature
for a lower temperature 15
17
With each press of the timing key, TIME ADJUSTMENT BUTTON
the indications change from the It is used to adjust the time and/or the timer (programmer)
following form: schedule)
Combustion will be maintained + to move the time forward
16 17
10 hours of combustion to turn back the hour
9 .hours. of combustion
.. ..
1 hour of combustion ON BUTTON (PILOT ON)
Se utiliza para encender el aparato.
The pilot light is on (red): the device is active or
INDICATOR BUTTON OF in preheating
SELECTION The pilot blinks (red) and emits a sound: 13
The temperature, the time, the time The flame goes out and indicates code of
Timer program can be false or an alarm. 24
selected by indication.
8
Digital indicators
They point out the preheating, the breakdowns, the altitude,
temperature, the time and the time set by the Timer.
Preheating 13
Breakdowns 24
9
Fuel to be used.
Know that more than 95% of operating problems stem from bad fuel.
liquid for portable heating devices. This type of malfunction is not covered by the warranty.
In the case of pump filling at a service station, check the correct cleaning of your
a container that must be completely free of any other liquid (water, diesel, gasoline, etc.) or
impurities. Reserve a quality container solely for this use.
10
. .
Which ones are the lowest quality?
.
.
The low-quality liquid fuel for portable heating devices shows a
It is yellow in color and has a pleasant smell.
Use liquid fuel for portable heating devices during the campaign.
.
WHAT HAS BEEN USED LIQUID FUEL FOR HEATING DEVICES
DEMAND QUALITY LAPTOP?
Empty the liquid fuel for portable heating devices from the removable tank.
Clean the tank three times with liquid fuel for heating devices.
clean laptop. make sure to fill it with clean kerosene. (Be sure that it has been
Emptying to the last drop of liquid fuel for portable heating appliances is bad.
Before filling it in with the appropriate one).
When the device does not function properly, including after having removed the
Liquid fuel for portable heating appliances is bad, consult your distributor.
localoal S.A.T.
Note: The repair of breakdowns caused by the use of impure or damaged fuel.
they will always be the responsibility of the customer even if the stove is under warranty.
11
Liquid fuel supply
Make sure the device is completely turned off before filling the tank.
1. Lift the cover of the compartment of the tank and remove the
tank.
If you remove the tank, this triggers the automatic shutdown of
Put the tank on the ground.
zPut the tank on the ground.
zRaise both handles and hold them together as indicated,
to lift the tank cap (for FH-1050) or
unscrew the cap (for FH-1030).
Once the adjustment is made, the information will be retained in memory until the plug is unplugged.
12
For FH-1030 For FH-1050
On
Press the ON key
The ON pilot will turn red.
The pilot is red at any requested power.
The preheating begins with '05' which is indicated on the digital display.
The indication evolves to 04, 03, 02, 01 and after 2 minutes it starts the
combustion and hot air is generated.
The odor absorption pilot lights up at the beginning then it
short.
20
13
Off
Press the OFF button
The flames disappear and the ON pilot goes out.
The odor absorption pilot stays on during the extinguishing cycle afterwards.
it goes out
The rotation of the fan may make more noise when the system of
odor absorption is activated.
The extinction will end when the odor absorption pilot turns off and the
The fan continues to run for 3 minutes to cool the device.
WARNING
Never turn off your stove by hitting it or pulling the plug.
NOTE
The odor absorption system will not activate if you do not follow the procedure of
extinction.
14
TEMPERATURE CONTROL
For FH-1030
For FH-1050
Selection of mode
According to your choice, you can opt for 3 modes: SAVE, AUTO, or MINI.
In SAVE mode
The device will stop automatically when the temperature of the
the room has exceeded the programmed temperature by 2ºC.
NOTE:
The temperature set by the AUTO mode will not necessarily match the
temperature indicated on the thermometer in your room.
The ambient temperature may be higher than the programmed one if the outside temperature is
high or if the device is operating in a small room.
15
1. Press the MODE key once or twice for the time to appear.
It appears on the digital panel.
The digital display indicates "0:00"
16
For FH-1030
For FH-1050
Mode Timer
The Timer mode cannot be used until after the time is set.
When the Timer button is activated, a sound signal will be heard when it is reached.
the set time.
17
CHILDREN'S SAFETY
NOTES:
A power outage or an earthquake when the Timer is programmed:
In case of electrical failure, the information will be erased and after the restoration of
the current, the digital panel will display the room temperature.
In case of power cut due to an earthquake, the panel will show E4 and the On light.
it will blink in red.
18
AIR-SENSOR DETECTOR
This heating device has been equipped with an air sensor device. In conditions
abnormal use of your device (poor ventilation in a very small room) causes the
automatic shutdown of your device.
IMPORTANT
Any security intervention or modification is completely prohibited. In addition to the annulment.
automatic warranty, you could run risks arising from poor operation of the
systems that control your security.
RESTRICTION OF USE
This heating device cannot be used in enclosed spaces or rooms such as:
caravans, boats, vehicle cabins, etc.
IMPORTANT
zSince the stove generates a lot of heat, never place it less than 1 meter away from
combustible materials, for example, furniture, curtains, and clothing.
19
Warning!
All maintenance must be done with the device turned off, unplugging it from the
power outlet and when the device is completely cold.
Do not dismantle the security systems, the electromagnetic bomb, or any component.
electric.
Use a vacuum cleaner to remove dust from the hot air outlet.
Remove the air filter from the device and clean it with a vacuum cleaner or
to wash it.
20
21
Warning
When you go to remove the liquid fuel from the tank, make sure that the device is
turned off and unplugged.
The hole allows for the drainage of water and fuel from the fixed tank.
If the poor combustion continues despite the above maintenance, please contact your
purchase establishment or the usual S.A.T.
22
The following situations may occur during operation
normal. First, check the potential causes of the failure before
consult it with your place of purchase.
Smoke and odor emanate from the device. The coating of the combustion chamber and/or the
dust burns.
Ventilate the room for 10 to 15 minutes to suppress
the smoke and the smell and submit your stove for repair.
The electromagnetic bomb emits a bubble of air can form in the system of
noise and flames are not stable. fuel leak.
When the air bubble has disappeared, the flames
they will become stable.
After several starts and a sufficient amount of fuel does not reach the system.
turned off, a white smoke may come from the device's combustion.
escape from the device and emit a If error code E1 manifests on the digital screen,
color. press first on OFF and then on ON.
Sometimes a slight noise can be heard. The crackling is due to the metal contracting and
put it back in place. This is normal.
The device does not turn back on directly. This requires 1 or 2 minutes of preheating.
after the extinction.
The burner head turns red. It turns red at minimum power.
This is normal, unless the ignition is done wrong and
that the flames disappear without reason.
The flames turn bright red-orange. They blush and it is normal.
This happens especially when:
The device is used
where the air is salty, like near the sea
where the air is dusty.
where the environment is humid.
where the device is used near a humidifier
ultrasound.
There is a noise like that of flowing water or that This occurs when the flow of fuel passes from the tank
boil. removable to the fixed deposit and it is normal.
The timer cannot be set correctly. The current hour has not been scheduled.
The device does not turn on at the scheduled time. It has not been able to work due to a power outage.
a tremor or another small shock.
Reprogram the timer again.
Check that the time is correct. 16
The fuel is spilling from the tank. The tank cap is open, causing a deposit.
of dust and poor airtightness.
6 12
El piloto de combustible parpadea y la combustión Puede que haya un depósito de polvo o de
it does not take place while the deposit is full. water in the punch filter. 21
Clean it and place it back.
The ON button is unresponsive. The child safety feature is 18
probably activated. Delete the
function.
23
The error codes with the luminous signs indicate
problems.
For FH-1030 For FH-1050
zThe ignition does not take place or the flames are not stable.
(The ignition security system has been activated).
zPresence of water in the device.
(The combustion safety system has been activated).
zThe flames are not stable and the flames rise too high.
The combustion security system has been activated.
zPresence of water or dirt in the device.
(The combustion safety system has been activated).
z Failed call detected.
(The error appears when the flame is detected before the
ignition process begins.
zAllthe lights are on. The power plug is not plugged in correctly.
Power cut. (The security system has been activated).
24
If normal operation has not been restored or if the device shows a
error code that does not appear in the list, disconnect the device and then reconnect
Plug the plug into the socket and press the ON button.
If the reset does not occur, contact your place of purchase.
IN CASE OF MALFUNCTIONS OF THE DEVICE, CONTACT SERVICE
TECHNICIAN OF YOUR DISTRIBUTOR NIPON ANDINO S.A.
YOU CAN FIND YOUR ADDRESSES AND CONTACT PHONES IN
[Link]
Unplug and plug the stove back in (the operation must be restarted)
pressing the OFF key, the ON key will not operate in this case.
Remove any objects that may be obstructing. 5
25
In the event that the parts need to be replaced, contact your establishment or S.A.T.
habitual.
FORWARD
3. Clean the body of the device, the filter
of air and the entry of hot air with 20
a dry cloth.
26
SPECIFICATIONS
MODEL FH-1030 FH-1050
Type Gasification to direct injection
27