Obtaining Oil Sample for Analysis{1302, 1348, 3030, 3080, 3278, 4011, 4070, 5050, 5056, 5095, 7542}
Fecha de publicacin -24/03/2009
i03547304
Obtaining Oil Sample for Analysis{1302, 1348, 3030, 3080, 3278, 4011, 4070, 5050, 5056, 5095, 7542}
SMCS - 1302; 1348; 3030; 3080; 3278; 4011; 4070; 5050; 5056; 5095; 7542 Agricultural Tractor: All Articulated Truck: All Asphalt Paver: All Backhoe Loader: All Challenger: All Cold Planer: All Combine: All Compact Track Loader: All Compact Wheel Loader: ALL Earthmoving Compactor: All Excavator: All All Wheeled Excavators Forest Products: All Integrated Toolcarrier: All Landfill Compactor: All Load Haul Dump: All Mini Hydraulic Excavator: All Motor Grader: All Multi Terrain Loader: All Off-Highway Truck/Tractor: All Paving Compactor: All Pipelayer: All Road Reclaimer/Soil Stabilizer: All Skid Steer Loader: All Soil Compactor: All Telehandler: All Track Feller Buncher: Caterpillar Track-Type Loader: All Track-Type Skidder: All
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 27/04/2012
Bsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 1348, 3030,... Page 2 of 27
Track-Type Tractor: All Underground Articulated Truck: All Wheel Dozer: All Wheel Feller Buncher: All Wheel Loader: All Wheel Skidder: All Wheel Tractor-Scraper: All
Introduction
This Guideline enables dealers and the dealer's customers to benefit from cost reductions which were made possible through an established Contamination Control Program. Fluids that are used in Caterpillar machines are highly effective unless the fluid contains damaging amounts of contaminates. Therefore, every effort must be made in order to reduce the contamination level within Caterpillar fluid systems. Caterpillar makes ongoing changes and improvements to the Caterpillar products. This guideline must be used with the latest technical information available from Caterpillar in order to ensure that such changes and improvements are incorporated when applicable. For questions or additional information concerning this guideline, submit a feedback form in the Service Information System website. In order to address an urgent need, please use the following to relay your request to Caterpillar Repair Process Engineering: Cat Dealer Technical Communicator Dealer Solution Network Cat Technical Representative Knowledge Network (on-line) If a Contatmincation Control Guideline is required, but not available in SIS Web, submit a feedback form in the Service Information System website.
Summary
A good oil sample that accurately represents the condition of the fluid system is vital for the success of any analysis program. For this reason, the oil should be at the system operating temperature or at least 50 C (120 F) if the normal operating temperature cannot be reached when the sample is taken. The following guideline describes the methods in order to obtain oil samples from machine fluid systems. Bottle sampling (pressure and suction) and portable particle counter methods are included in this guideline. These processes are used when an oil sample is taken or when an on-line particle count is taken on any fluid system (such as hydraulic, steering, power train, engine and final drive).
References
References Table 1
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 27/04/2012
Bsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 1348, 3030,... Page 3 of 27
Title Valve Installation for Scheduled Oil Sampling of Engine, Transmission, Hydraulics, and Steering Count on Caterpillar Particle Analyzers Tool Operating Manual for S40 Portable Particle Analyzer Oil Analysis Bottle Label
NOTICE
Keep all parts clean and keep all parts free of contamination.
Hot oil and hot components can cause personal injury. Do not allow hot oil or hot components to contact the skin.
Table 2 Part Number 162-5791 170-8500 210-5530 GE06L1/4NP TA3C 188-0639 Parts Description Shop Towel S40 Particle Counter Quick Disconnect Male Connector Hose as Replacement Parts
These items can be obtained by contacting Caterpillar Capital Tooling Group. A proper fitting will be provided at no cost.
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 27/04/2012
Bsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 1348, 3030,... Page 4 of 27
g01281548
Note: Refer to Contamination Control Guideline, PEVN4831, "Count on Caterpillar Particle Analyzers" and refer to Tool Operating Manual, NEHS0799, "Manual for S40 Portable Particle Analyzer" for proper installation and operation. Caterpillar recommends to connected the on-line particle counters directly to the SOS valve. Note: Refer to the Operation and Maintenance Manual for the SOS valve locations. Refer to the Test and Adjust Manual in order to obtain the system pressures. Prepare all equipment used to sample oil in advance in order to prevent contamination prior to taking a sample.
Illustration 2
g01281550
1. Determine the fluid system pressure at the location where the sample is to be taken (SOS valve). For proper supply hose and hardware refer to Contamination Control Guideline, PEVN4831, "Count on Caterpillar Particle Analyzers" and refer to Tool Operating Manual, NEHS0799, "Tool Operating Manual for S40 Portable Particle Analyzer".
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 27/04/2012
Bsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 1348, 3030,... Page 5 of 27
2. Exercise the machine until the sampled fluid system is up to the normal operating temperature or at a minimum of 50 C (120 F). 3. Park the machine on level ground. Lower all of the attachments. Engage the parking brake. 4. Set the engine at low idle. All systems must be in a safe position.
g01281551
5. Remove the dust cover from the SOS valve. Refer to the Operating and Maintenance Manual for the SOS valve locations.
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 27/04/2012
Bsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 1348, 3030,... Page 6 of 27
Illustration 4
g01281552
6. Clean the SOS valve with a clean 162-5791 Lint Free Towel .
g01281553
Illustration 6
g01281554
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 27/04/2012
Bsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 1348, 3030,... Page 7 of 27
Typical particle counter supply hose attached to the SOS valve (low pressure hose shown)
g01281555
9. Secure the particle counter's discharge hose with a catch basin. 10. If the sampled fluid system has cooled down, exercise the machine until the sampled fluid system is up to normal operating temperature or a minimum of 50 C (120 F).
NOTICE
Do not move the machine while the particle counter in connected. Moving the machine in this condition could cause damage to the machine and/or the particle counter.
Note: Allow power train circuits to idle for a minimum of ten minutes prior to particle counting. This will allow entrapped air to escape from the sampled oil. Air trapped in the oil will distort the particle counter readings. 11. Operate the particle counter according to the manufacturer's instructions in order to obtain an oil sample reading.
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 27/04/2012
Bsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 1348, 3030,... Page 8 of 27
g01281556
12. After testing, disconnect the particle counter hose assembly from the machine. After testing, disconnect the hose assembly from the particle counter. Drain the hoses. Cap all the hose ends. Store the particle counter and store the hoses in a clean location.
g01281557
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 27/04/2012
Bsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 1348, 3030,... Page 9 of 27
13. Install the dust cap onto the SOS valve. Make sure that the cap is clean on the inside. 14. Properly dispose of any waste oil.
Table 3 Part Description Shop Towel Sample Bottle Group Sample Bottle Probe Holder Probe Assembly (1) Sample Bottle Shipping Container
Hot oil and hot components can cause personal injury. Do not allow hot oil or hot components to contact the skin.
Note: Refer to Operation and Maintenance Manual for the SOS valve locations. Refer to the Test and Adjust Manual in order to obtain the system pressure. Only perform a bottle sample when the system pressures are below 3450 kPa (500 psi). Prepare all equipment used to sample oil and protect the equipment from contamination.
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 27/04/2012
Bsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 1348, 30...
Page 10 of 27
g01281558
1. Fill out the SOS label. Pay special attention to the serial number, sample data, service meter units on the equipment, service meter units on the oil, oil type, oil brand and the amount of oil added. Indicate if the oil was changed after the sample was taken.
g01281559
2. Open the 169-8373 Sample Bottle package. Remove the sampling probe tube from the bag.
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 27/04/2012
Bsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 1348, 30...
Page 11 of 27
g01281560
3. Insert the open sampling probe tube into and through the 162-8873 Sample Bottle Probe Holder counter bored end. Pull the probe tube all the way through the holder until the sampling needle seats in the holder.
Illustration 13
g01281561
4. Remove the sampling bottle from the package. Install the cap with two holes onto the bottle. Install the probe tube into one of the holes in the cap.
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 27/04/2012
Bsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 1348, 30...
Page 12 of 27
Illustration 14
g01281562
5. Return the assembled bottle and return the probe back into the package in order to prevent contamination. 6. Exercise the machine until the system oil to be sampled is up to normal operating temperature or at a minimum of 50 C (120 F). 7. Park the machine on level ground. Lower all the attachments. Engage the parking brake. 8. Set the engine at low idle. Make sure that all systems are in safe positions. Refer to the Operation and Maintenance Manual.
Illustration 15
g01281564
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 27/04/2012
Bsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 1348, 30...
Page 13 of 27
Illustration 16
g01281565
10. Clean the SOS valve with a clean 162-5791 Lint Free Shop Towel .
Illustration 17
g01281566
11. Purge the SOS valve by pressing the 8T-9208 Purge Probe onto the SOS valve. Purge a minimum of one sample bottle of oil or more if it is required to ensure that all the dead volume of the fluid is purged and the sampling nipple is internally cleaned. Note: If the oil flow is slow at low idle, it may be necessary to have someone accelerate the engine.
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 27/04/2012
Bsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 1348, 30...
Page 14 of 27
g01281567
g01281568
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 27/04/2012
Bsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 1348, 30...
Page 15 of 27
g01281576
14. Rinse the sample bottle and rinse the probe tube with the system oil. Rinse the bottle by filling the bottle half full with the system oil.
g01281577
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 27/04/2012
Bsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 1348, 30...
Page 16 of 27
Illustration 22
g01281578
Illustration 23
g01281579
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 27/04/2012
Bsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 1348, 30...
Page 17 of 27
17. Fill the sample bottle to the "fill range" imprinted on the bottle, but do not fill beyond the fill mark. Note: Do not fill the bottle beyond the fill mark. Filling beyond the fill mark will not allow for proper lab mixing.
Illustration 24
g01281580
18. Remove the sampling probe tube from the bottle lid. Save the knurled probe holder and discard the probe tube.
Illustration 25
g01281581
19. Immediately replace the two-hole lid on the sample bottle with the solid lid (no hole). Dispose of the lid with two holes.
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 27/04/2012
Bsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 1348, 30...
Page 18 of 27
Illustration 26
g01281583
g01281585
21. Place the bottle with the completed information label into a 4C-4600 Shipping Container or take the bottle and label to the lab.
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 27/04/2012
Bsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 1348, 30...
Page 19 of 27
Illustration 28
g01281586
Illustration 29
g01281588
23. Install the dust cap onto the SOS valve and check that the cap is clean on the inside.
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 27/04/2012
Bsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 1348, 30...
Page 20 of 27
Parts List Quantity 1 2 1 1 1 Part Number 162-5791 169-8373 1U-5718 4C-4600 1U-7648 1U-8757
Table 4 Part Description Shop Towel Sample Bottle Group Oil Sampling Vacuum Pump Sample Bottle Shipping Container Tube Cutter Tube
Hot oil and hot components can cause personal injury. Do not allow hot oil or hot components to contact the skin.
Note: Typical nonpressurized systems are reservoirs, differentials, final drives, or return lines (drains). The sample location should be near the middle of the reservoir's fluid level and away from the sidewall. The sample location should be where the fluid is normally in motion, thoroughly mixed, and at normal operating temperature. The sample should be taken as soon as possible after the machine exercising has been stopped. Prepare all sampling hardware before an oil sample is taken. Note: Never use the same vacuum pump for obtaining both oil and coolant samples. Although the fluid does not enter the barrel of the pump, a small residue of glycol from the coolant remains in the pump and can contaminate the oil sample. This will indicate a "false positive" coolant leak in the oil system being sampled.
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 27/04/2012
Bsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 1348, 30...
Page 21 of 27
Illustration 30
g01281590
1. Fill out the SOS label. Pay special attention to the serial number, sample data, service meter units on equipment, service meter units on oil, oil type, oil brand and the amount of oil added. Indicate if the oil was changed after the sample was taken.
g01281591
2. Measure the tubing and then cut new 1U-8757 Tubing to the length of the dipstick. If there is no dipstick, cut the tubing so that the tubing reaches about halfway into the oil depth of the compartment being sampled. Note: Use a 1U-8757 Tube Cutter in order to prevent the tubing from being contaminated.
Illustration 32
g01281593
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 27/04/2012
Bsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 1348, 30...
Page 22 of 27
3. Install tubing into the 1U-5718 Vacuum Pump . The bottle end of the tubing should be approximately 25.4 mm (1 inch) beyond the base of the vacuum pump head.
Illustration 33
g01281594
Illustration 34
g01281595
5. Store the vacuum pump assembly and store the clean bottle cap in the plastic bag until the parts are ready for use. 6. Exercise the machine fluid to be sampled until the fluid system is up to normal operating temperature. If normal operating temperature cannot be reached, then 50 C (120 F) is acceptable. 7. Park the machine on level ground. Lower all the attachments. Engage the parking brake. 8. Shut the machine off. Make sure that all the systems are in safe positions. Refer to the Operation and Maintenance Manual.
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 27/04/2012
Bsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 1348, 30...
Page 23 of 27
Illustration 35
g01281596
9. Clean the sample location using a clean 162-5791 Lint Free Shop Towel .
Illustration 36
g01281597
10. Keep the sample bottle vertical when taking samples. Pump the vacuum pump handle in order to create a vacuum. Note: If the bottle is tilted, the oil will enter into the suction of the barrel of the vacuum pump. This will cause cross contamination of subsequent samples.
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 27/04/2012
Bsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 1348, 30...
Page 24 of 27
Illustration 37
g01281598
11. Fill the sample bottle half full with system oil. 12. Remove the bottle from the vacuum pump.
Illustration 38
g01281577
13. Install a clean lid and shake the bottle vigorously for several seconds.
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 27/04/2012
Bsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 1348, 30...
Page 25 of 27
Illustration 39
g01281578
14. Empty the bottle into a waste oil container. 15. reinstall the sample bottle to the vacuum pump.
Illustration 40
g01281599
16. Take the oil sample in the same manner. Fill the bottle to the "fill range". Note: Do not fill the bottle beyond the fill mark. This will not allow for proper lab mixing.
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 27/04/2012
Bsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 1348, 30...
Page 26 of 27
Illustration 41
g01281583
17. When the oil bottle is filled, remove the bottle from the vacuum pump. Cap the bottle with a clean lid (no holes). 18. Clean the outside of the bottle.
Illustration 42
g01281585
19. Place the bottle with the completed information label into a 4C-4600 Shipping Container or take the bottle and the label to the lab. 20. Remove the tubing from the vacuum pump and discard the tubing in the probe location.
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 27/04/2012
Bsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 1348, 30...
Page 27 of 27
Illustration 43
g01281596
21. Clean any covers, caps, plates, etc that have been removed.
Copyright 1993 - 2012 Caterpillar Inc. Todos los derechos reservados. Red privada para licenciados del SIS. Fri Apr 27 07:29:17 EST 2012