0% found this document useful (0 votes)
107 views1 page

Terrace Plan

This document outlines the specifications and guidelines for a working drawing of a building designed for ground plus two floors. It includes details on dimensions, materials, and construction practices that must be followed, as well as a schedule for doors and windows. The document emphasizes the importance of consulting an architect before execution and adhering to specified construction standards.

Uploaded by

Mayuri Mahajan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
107 views1 page

Terrace Plan

This document outlines the specifications and guidelines for a working drawing of a building designed for ground plus two floors. It includes details on dimensions, materials, and construction practices that must be followed, as well as a schedule for doors and windows. The document emphasizes the importance of consulting an architect before execution and adhering to specified construction standards.

Uploaded by

Mayuri Mahajan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

WORKING DRAWING II

NOTE :
1. ALL DIMENSION ARE IN METRIC UNITS AND ONLY WRITTEN
DIMENSIONS SHOULD BE FOLLOWED EVERYWHERE.
2. R.C.C. DESIGN IS FOR GROUND+2 FLOOR.
3. DISCREPANCY IF ANY SHOULD BE BROUGHT TO THE NOTIC OF
AN ARCHITECT PRIOR TO EXECUTION.
4. EXCAVATION AND MASONRY WORK SHOULD NOT BE
EXECUTED PRIOR TO THE CHECKING OF AN ARCHITECT.
5. LOCATION AND SITTING OF THE BUILDING SHOULD BE
CHECKED BY AN ARCHITECT.
6. THE LENGTH AND WIDTH OF COLUMN AS PER GIVEN IN TABLE
SHOULD BE STRICTLY FOLLOWED.
7. BEARING CAPACITY OF SOIL= /SQ.FT
8. CONCRETE MIX SHOULD BE M-20
9. REINFORCEMINT SHOULD BE SHOWN TO CONSULTING
ENGINEER.
10 . PROPER STRUTTING SHOULD BE DONE TO THE ADJIONING
BUILDING.
RIGDE LINE
SPECIFICATION
1. ALL WALLS ARE OF 230M THICK BURN BRICK MASONARY.
2. EXTERNAL DOUBLE COAT SAND FACED PLASTER.
3. INTERNAL SINGLE COAT GYPSUM PLASTER.
4. FLOORING AS PER GIVEN DETAIL.
100MM O
R/W PIPE
SCHEDULE OF OPENING
E
:70 AC
; 1 RR

DOORS
E
OP O T

SYMB. SIZE LINTEL NO.S


SL G T
E

D 1200 X 2100 2100 06


IN
BA OF

D1 1000 X 2100 2100 06


CO RO

D1 750 X 2100 2100 06


BB R P
IN ATE

O 1000 X 2100 2100 02


W

WINDOWS
SYMB. SIZE LINTEL SILL NO.S
W 1200 X 1500 2100 600 12
W1 1000 X 1200 2100 900 08
D1 V 600 X 450 2100 1650 06
D1
UP
100MM O R/W
PIPE
BUNGALOW DESIGN
WA
IN TER REVISION :
BB P
C O R OO DRAWING NO:
B A F ING
SL TO INTERNAL SIGN EXTERNAL SIGN
O PE TER
; 1:7 RAC
0 E
TITLE : TERRACE PLAN
HEAD ROOM PLAN
SCALE-1:50 STAMP :
SHEET NO.
DATE :
NAME : MAYURI M MAHAJAN
SUBJECT : WORKING DRAWING
3RD YEAR NORTH
APCOA , PUNE