13th July Morning Gathering, Training on the Site, Making the Daily Journal and Meeting, Greeting to SaiBouKyou, Cleaning the Staffroom and Greeting to TMP.
7th July Sight-seeing at Hiroshima 8th July Free time (Tanabata Festival)
Tokuyama Corporation SE 1
SE 8 Fumed Silica SE 3 SE 6 SE 7 SE 9
Polysilicon
SE 9 : Electrical Room
Safety check Low voltage VVVF (variable voltage variable frequency) UPS (uninterrupted power supply C 1400) VESDA (very early smoke detector apparatus) Haloon gas
Annubar
Similar to a pitot tube used to measure the flow of gas or liquid in a pipe. measures the difference between the static pressure and the flowing pressure of the media in the pipe. The volumetric flow is calculated from that difference using Bernoullis principle and taking into account the pipe inside diameter. The biggest difference between an annubar and a pitot tube is that an annubar takes multiple samples across a section of a pipe. In this way, the annubar averages the differential pressures encountered accounting for variations in flow across the section.
Sensors that are used to measure temperature by correlating the resistance of the RTD element with temperature. The element is usually quite fragile, so it is often placed inside a sheathed probe to protect it. Resistance thermometers use electrical resistance and require a power source to operate
Air supply Regulator Flow Indicator Bubbler LIT Operates by supplying compressed air into a bubbler tube at a constant rate with its opening placed near the bottom of the liquid. Measures the pressure required to force air through the tube and generates a 4-20 mA signal which is proportional to the depth of the liquid.
Ultrasonic Meter
A type of flow meter that measures the velocity of a liquid or gas (fluid) by using the principle of ultrasound. Using ultrasonic transducer, the flow meter can measure the average velocity along the path of an emitted beam of ultrasound, by averaging the difference in measured transit time between the pulses of ultrasound propagating into and against the direction of the flow. Ultrasonic flow meters are affected by the temperature, density and viscosity of the flowing medium.
Air will be supplied to line A where it will push the instrument close. A signal will be send to DCS to inform that the valve is open. Air will be supplied out through line B. This is to release the pressure on the other side of the chamber. When there is a power break down, the air will be supplied to line B, where it will push the instrument open. Again, a signal will be send to DCS to inform that the valve is close. Maintenance is done every year
Fire Water
SE 8
Marshaling cabinet room CS5 HCL waste pit 5E-2440 plat exchanger Silica plant dryer
Floor and metal frame are all in anti-acid coating. For the bubbler, teflon tube is used as sheath.
Open the coil to prevent the instrument from damage during mechanically maintenance.
SE 7
DCS room Toshiba Ciemac cleaning of event recorder FCS and marshaling room using old version of VESDA A7 D7 BJ7 Etching room
A7
Replacing Teflon membrane
Removal of filter
D7
It has excellent high temperature mechanical properties. Also has chemical corrosion resisting. High temperature oxidation resisting, wear-proof capability and less specific weight.
Magnetic Flowmeter
A magnetic field is applied to the metering tube, which results in a potential difference proportional to the flow velocity perpendicular to the flux lines. The physical principle at work is electromagnetic induction. Disadvantage : -can only measure conductive liquid. Advantages : - as the liquid could go directly through, there is no pressure drop. - sensor is not contact with liquid.
Polishing of Belljar. Cleaning machine part mitsubishi. Dryer temperature yearly inspection Cutting pure water washing dryer cooler check inspection packing Optical fiber sensor if there is nothing within the range of the sensor, the level value is high.
SE 6
Finishing process Ph calibration every month
Finishing Process
Pure water chemical washing pure water washing heater/dryer cooler Cleaning is done monthly.
pH Calibration
HCL is used to clean and pure water is used to wash. Early value is taken before calibration. Buffer solution pH 7 is for zero adjustment. Buffer solution pH 9 is for span adjustment. Acidic side calibration range is 4 - 9. Alkali side calibration range is 7 9.
PH Calibration
SE 3
Electrical room Ph calibration every month
Electrical Room
Power supply of BJ 3. One supply for two belljars different from TMSB. Observed filament seeding and belljar cleaning.
WWT
Ph meter Yokogawa Yanaco COD (chemical O2 Demand) Shimadzu TNPC (total nitrogen/phosphorous analyzer) Ph calibration Pump cleaning
pH Calibration
HCL is used to clean and pure water is used to wash. Early value is taken before calibration. Buffer solution pH 7 is for zero adjustment. Buffer solution pH 9 is for span adjustment. Acidic side calibration range is 4 - 9. Alkali side calibration range is 7 9. MLSS (mixed liquid suspended solids) to measure the clearness of the water.
Pump Cleaning
HCL is used to remove the scale. The pump hose is stepped to remove the scale from inside the hose.
Motoyama
Control valve maintenance
Assembling Disassembling Steam cleaning Nitrogen dryer Testing
Motoyama Workshop
Observed the assembling, cleaning and checking process for eccentric rotary valves (ceramic rotary valves). Valve packing : yarn packing and v-packing (teflon) Lapping compound to smoothen the seat. Seat & Plug Touch check Gasket lubrication is using demnum grease. Seat leak test Body test
The stem will be sprayed and will be put inside the seat. If the color at the plug is smooth, then the seat is alright. If not smooth, lapping compound is still needed.
Is done to check whether the seat is smooth and even that it can fit the plug. Test value is calculated using : Air 2.434 *cv*(P1+1.0033)*1.01 P1=4kg/cm2G Water 0.1428*cv*P1*leakage class
Body test
Body test is done to check whether the connection between the bonnet flange and body flange is correct.
Lapping compound
Assembling process
Instrumentation Workshop
Field instrumentation Yamaichi Valve disassembling from actuator and valve body. UV tube Pointer remover Pressure gauge daily maintenance PG calibration Differential pressure calibration Variable area flowmeter (rotameter) Pyolan tape
Pyolan tape
Numbe r
Colors CL, WH, BE, YE, GR, BL, RE
Width [mm,(in)]
Adhesive Holding Tensile Elongatio Length Thickness Strength Power Strength n [m,(yd)] [mm] [N/25mm] [mm,40 ] [N/50mm] [%] 50 (55yd)
K-10 srs.
25,50 (1",2")
0.16
10
0.1
300
UV tube
Study about variety type of gaskets
6503A 6500A 6503 8596V 7596V N7030 Glass fiber gasket 7010 7020 Special gasket Rubber gasket
Food
END