Configuration Wizard
Presentation
Configuration Wizard
Step 1 : NE Type
NE name as it will appear on map
NE location as it will appear on map
Letting these fields empty some applications do not work properly
Protection Type
User Interface Type
Optional Audio ESC Plug-in
(N/A in R2.1)
Configuration Wizard
Step 1 (continued) : Aggregate structure
Capacity of aggregate signal
Modulation scheme of ODU
Capacity
Modulation Choice
2 E1
4 QAM only
4 E1
4 / 16 QAM
8 E1
4 / 16 QAM
16 E1
4 / 16 QAM
32 E1
16 QAM only
Modulation agility is neither available for 2 E1 (4 QAM only) nor for 32 E1 (16 QAM
only) due to spectrum width used in these radios.
Capacity and modulation choices are available depending on the Licence Key
located inside the flash card. Limitations in combo boxes do not apply in the
wizard.
Configuration Wizard
Step 2 : User line interface, PDH
Tributary impedance
(75 or 120 ohms)
Configuration Wizard
Step 2 (continued) : User line interface, Data
This tab will appear only in 16 E1 Data configuration
Enable / Disable
Ethernet port
Speed to be set up
Configuration Wizard
Step 2 (continued and finish) : User line interface, Data FCS
This tab will appear only in 16 E1 Data configuration
Discard errored frames depends highly on the customer applications.
Configuration Wizard
Step 3 : RT parameters configuration
Configuration Wizard
Step 4 : Link Identifier
In case of Link Identifier Mismatch alarm, signal is sent anyway (Melodie behavior was
to generate an AIS)
Bug : If Expected Identifier is equal to Sent Identifier, no alarm is raised.
Configuration Wizard
Step 5 : Restoration criteria
Configuration Wizard
Step 6 : OSPF Areas configuration
Add the relevant OSPF area(s). Generally, only one is declared other than ospf 0.
Bug : If you are modifying a file, add an ospf area instead of removing / add
Configuration Wizard
Step 7 : Local configuration
Configuration Wizard
Step 8 : PPP interfaces
Configuration Wizard
Step 9 : Static Routes
Configuration Wizard
Step 10 : I/O
"Bug" : Java behavior : for a field to be taken into account, the operator has to fill in
the information and to click somewhere else in the page.
"Bug" : It is not so obvious, but polarity can be set up (active opened / active closed)
Configuration Wizard
Step 11 : Configuration summary