BOILER

Brief Introduction
Satyakam
Mohapatra
Engineer(Mechanic
al)

Monnet Power Company Ltd

BOILER
In General, Aboileris a closed pressure vesselstrongly
constructed of steel or iron where water is converted to steam
by application of heat.
According Indian Boilers Act, 1923, Boiler" means a pressure vessel in which steam is generated for
use external to itself by application of heat which is wholly or
partly under pressure when steam is shut off but does not
include a pressure vessel,(i) with capacity less than 25 litres (such capacity being measured
from the feed check valve to the main steam stop valve);
(ii) with less than one kilogram per centimetre square design
gauge pressure and working gauge pressure; or
(iii) in which water is heated below one hundred degrees centigrade;

Monnet Power Company Ltd

Usage of Boiler
In Power Sectors
In Independent Power Plant(IPP)
& Captive Power Plant(CPP).
In Process Plants
In Oil Refineries, Paper Industry,

Sugar Industry, Chemical


Industry, Rice mill, Steel Industry
etc.
Monnet Power Company Ltd

Classification of Boiler
Criteria

Types

Content of Tube

Fire Tube Boiler, Water Tube Boiler

Type of firing

Solid, Liquid & Gas Fired

Type of Circulation

Natural Circulation, Natural


Assisted or Controlled Circulation,
Forced Circulation

Steam Pressure

Sub Critical Boiler, Super Critical


Boiler

Draught

Natural Draught, Mechanized


Draught(Forced, Induced,
Balanced)
Monnet Power Company Ltd

Content of Tubes
Fire Tube

Water Tube

In fire tube boiler hot


flue gas will be moved
inside the tubes &
water outside the tube.
In fire tube boiler mode
of firing is generally
internally fired.
In fire tube boiler
operating pressure
limited to 25 kg/cm

Monnet Power Company Ltd

In water tube boiler


water will be moved
inside the tube & hot
flue gases outside
the tubes.
Mode of firing is
externally fired.
Operating pressure
can exceed 125
kg/cm or more
5

FIRE TUBE
BOILER

WATER
TUBE
BOILER

Monnet Power Company Ltd

Type of Firing
Solid

AFBC

Atmospheric
Atmospheric
Fluidized
Fluidized Bed
Bed
Combustion
Combustion
Bed
Bed Material
Material
Used
Used Crushed
Crushed
Refractory(
Refractory( +
+
0.8
mm
to
-2.8
0.8 mm to -2.8
mm)
mm)
Velocity
Velocity 3-5
3-5
m/sec
m/sec
Coal
Coal F-Grade,
F-Grade,
Washery
Washery Reject
Reject
Combustion
Combustion
EffEff- 80-85%
80-85%

Liquid

CFBC

Circulating
Circulating
Fluidized
Fluidized Bed
Bed
Combustion
Combustion
Bed
Bed Material
Material
Used
Used -- Crushed
Crushed
Refractory
Refractory (( +
+ 0.8
0.8
mm
to
-2.8
mm)
mm to -2.8 mm)
Velocity
Velocity 7-8
7-8
m/s.
m/s.
Coal
Coal F-Grade,
F-Grade,
Washery
Washery Reject
Reject
Combustion
Combustion Eff.Eff.95
%
95 %
Monnet Power Company Ltd

Gas

PC
Fired
Pulverized
Coal Fired
Boiler.
Coal : F
Grade(30003500
Kcal/Kg) Size
is 65to 80.
No Bed is
Required
Combustion
Eff : 99 %

WHRB

Waste Heat
Recovery
Boiler
Waste Heat
from Flue
Gas of Other
process used
in boiler for
Steam
generation

AFBC

WHRB

Monnet Power Company Ltd

CFBC

PC
Fired

Type of Circulation
Natural
Natural
Circulation
Circulation

Density
Difference is
the driving
force.
Limited to
boiler with
drum operating
pressure
around 175
kg/cm2(g).

Assisted/Controll
Assisted/Controll
ed
ed Circulation
Circulation

Beyond
Beyond 175
175 kg/cm2(g)
kg/cm2(g)
pressure
pressure in
in a
a re
re
circulation
system,
circulation system,
circulation
circulation through
through the
the
evaporator
is
to
be
evaporator is to be
assisted
assisted with
with
mechanical
mechanical pumps
pumps to
to
overcome
frictional
overcome frictional
losses
losses in
in the
the tubes.
tubes. A
A
pump
pump called
called boiler
boiler
circulation
circulation pump
pump will
will
be
be placed
placed in
in the
the down
down
comer
between
the
comer between the
Drum
Drum &
& water
water wall
wall
ring
header
to
ring header to do
do this
this
function
is
called
function
is Ltd
called
Monnet Power
Company
controlled
circulation.
controlled circulation.

Forced
Forced
Circulatio
Circulatio
n
n

Mechanical
pumps are
used to over
come the
frictional
losses
Operating
pressure is
above 224.6
kg/cm2(g)
9

SH
SH

SH
SH
SH
SH

Separator
ECO
ECO

Drum

ECO
ECO

Water
from
Feed
Statio
n

Drum

Furnac
e Wall

Furnac
e Wall

BCP
BCP

W
W
W
W

CC
CC
Pump
Pump

Distributio
Distributio
n
n Header
Header

Natural
Circulation

Distributio
Distributio
n
n Header
Header

Assisted
Circulation
Monnet Power Company Ltd

Economiser
Economiser

Forced
Circulation
10

Steam Pressure
Sub Critical
Boiler

Super Critical
Boiler

Boilers Operating below


the Critical
Pressure(224.6
kg/cm2(g)).
These are recirculation
type or once through .
Steam Drum is required
to separate water &
steam.

Monnet Power Company Ltd

Boilers Operating above


Critical Pressure (224.6
kg/cm2(g)) & Critical Temp
(374 00C)
These are only Once
Through Type.
Drum is not required as
cycle medium is a single
phase fluid having
homogenous property.
11

DRAUGHT
Natural
Draught

Mechanized
Draught

Forced
The draught
required for the
flow of air & gas
inside the boiler
is created by
chimney alone

Here
Here Fans
Fans are
are
used
to
draw
used to draw
air
air from
from
atmosphere
atmosphere &
&
push
into
the
push into the
furnace.
furnace.
The
The entire
entire
boiler
boiler will
will be
be
kept
above
kept above
atmospheric
atmospheric
pressure
pressure
Monnet Power Company Ltd

Induce
d

Fans
Fans installed
installed
at
at the
the outlet
outlet of
of
boiler,
boiler,
evacuate
evacuate the
the
gases
from
gases from
furnace.
furnace. So
So a
a
negative
Pr.
negative Pr. Is
Is
developed
in
developed in
furnace
furnace &
& air
air
from
from
atmosphere
atmosphere
enters
enters the
the
furnace
furnace

Balanc
ed
Both
Forced &
Induced
draught
fans are
used to
derive the
benefits of
both
systems.
12

Boiler Mountings

Safety Valves
Feed Check Valves
Pressure Gauge
Drum Water Level gauge
Blow Down Valve
Main Stop Valveetc

Boiler Mounting are basically used for safe


operation of Boiler.

Monnet Power Company Ltd

13

Description of Boiler Mountings


Safety Valve : The Function of a safety valve is to blow off steam

when the pressure in the boiler exceeds the working pressure.


Feed Check Valve : A feed check valve is used to control the supply

of feed water to boiler & also to act as a non-return valve.


Pressure Gauge : Pressure gauge indicates the pressure of steam in

a boiler.
Drum Water Level Gauge : The Function of water gauge glass is to

indicate the water level in the Drum.


Blow Down Valve : Blow down Valves are designed for continuous

use to control the concentration of dissolved solids in boiler water.


Main Stop Valve : Function of a steam stop valve is to stop or allow
Monnet Power Company Ltd

the flow of steam from the boiler to Main Steam line.

14

Specification of Boiler
(Monnet Power Company Ltd)

Maker :

Bharat Heavy Electricals Ltd

Boiler Maker No :

Type :

Controlled Circulation, Sub Critical, Two Pass, Single

Reheat,

Balance draught, Tangential PC Fired.

0675,0676

Boiler Rating :

51793 m 2

Boiler Drum Design Pressure :

Boiler Hydrotest Pressure :

315 kg/cm2(g) ,(For RH-78 kg/cm2(g) )

Boiler Drum Design Temp :

369 OC

Steam flow at SHO:

Steam pressure at SHO:

Steam temperature at SHO:

Reheat Steam flow:

Steam pressure at RHI:

Steam temperature at RHI:

Steam pressure at RHO:

Steam temperature at RHO:

Boiler Efficiency:

210 kg/cm2(g)

1700TPH
192.2 kg/cm2(g)
540OC
1468.1TPH
52.4 kg/cm2(g)
337 OC
52.4 kg/cm2(g)
540OC

Monnet Power
86 %Company Ltd

15

Boiler Pressure parts


The Following parts generally comes under this
category
Drum
Economiser
Water Walls
Radiant Roof Tubes
Steam Cooled Walls
LTSH Coil
Div Panelette SH
Platen SH
Rehaeter Coil Assy.
Monnet Power Company Ltd

16

RH O/L Hdr

Monnet Power Company Ltd

17

Monnet Power Company Ltd

18

Water Circuit
Feed
Water
Statio
n

ECO
Feed
Pipe

Water
Wall
Outlet
Headers

ECO I/L
Header

Water
Wall
Tubes

ECO
Coil

Botto
m Ring
Header

Monnet Power Company Ltd

ECO O/L
Header

Down
Comer

ECO
Link

DRUM

19

BOILER DRUM
In

Separation

Monnet Power Company Ltd

a Sub-Critical re-circulation boiler, the


drum plays an important role. In the
erection of a Power Boiler, the lifting of the
Boiler Drum is the first mile stone activity.
The Functions of Drum are

of saturated steam from the steamwater mixture produced by evaporating tubes.


Mixing feed water from economiser and water
separated from steam-water mixture, and recirculate through the evaporating tubes
Carrying out blow down for reduction of boiler
water dissolved solid concentration.
Treatment of Boiler Water by chemicals
20

TECHNICAL DATA OF DRUM


210 kg/cm2(g)

Operating Pressure

197 kg/cm2(g)

Water Holding Capacity

60 m3

Design Temperature

369 0C

No of Cyclone Separator

92(46X2)

No of Secondary Drier

124

OD of Drum

1778 mm

Thickness

155 mm

(Straight Portion/Dished Portion)

Weight of Drum without Internals 214.7 MT

Monnet Power Company Ltd

Design Pressure

21

SH
Conn
Pipe
Stubs

4
5

2
Taping No

Safety
Valve
Stub

Riser
Stub

Feed
Nozzle

Details

Qty(In Nos)

DWLG & EWLI

15 (Both Side)

Test Tapings

Air Vent

Chemical Feed Nozzle

DWLG & EWLI

15 (Both Side)

DC
Nozzle

Monnet Power Company Ltd

22

STAGES OF STEAM & WATER SEPARATION :

Separation takes place in the concentric cylinder of Turbo


separator.
The second stage of separation takes place in the
corrugated sheets connected to the top of the Turbo
separator.
The third and final stage of separation takes place in
Screen Driers.
The Anti Vertex spider is provided at the inlet of Down
comer to avoid whirl formation in DC.

Monnet Power Company Ltd

The main components of Boiler Drum:


Turbo separator
Screen Dryer
Baffle Plate
Anti Vertex Spider

23

Drier
Drier Assembly(62X2)
Assembly(62X2)

Drum Internals of MPCL


Boiler

Turbo
Turbo
Separat
Separat
or(2X46
or(2X46
))
Separatin
Separatin
g
g
Chamber
Chamber

Feed
Feed Header
Header
Monnet Power Company Ltd

DC Nozzle

Feed
Feed Nozzle
Nozzle

24

TURBO SEPERATOR

Monnet Power Company Ltd

25

Economiser System
O Application of economisers is to capture the heat

from flue gas and transfer it to the feed water.


This raises the temperature of the boiler feed
water, lowering the needed energy input, in turn
increases efficiency.
O Total System Consists of ECO feed line, Eco I/L
Header, ECO Coil Assy, ECO O/L Hdr, ECO Link to
Drum.
TECHNICAL DATA
No of Banks

3 Banks( 92 Sets)

Total Heating Surface


of ECO System

20,000 Sq. Mtr

Total Water Holding


Capacity

150 m3

Monnet Power Company Ltd

26

Description

Size
(DiaXThick)
(In mm)

Design
Temp( 0C)

Design Pressure
(kg/cm2(g))

ECO Feed Pipe

457.2X50

283

219.7

ECO Inlet
Header

508X65

283

215

ECO Coil

38.1X4.5

336

215

ECO Outlet
Header

406.4X60

353

210.8

ECO Link to
Drum

368X40
323.9X36

357

210.8

Monnet Power Company Ltd

27

ECONOMISER COIL

Monnet Power Company Ltd

28

Water Wall System


O The water walls are tube panels through which

the water for steam generation will be


circulated. In Water Wall only heat is added to
evaporate the feed water to steam.
O It also forms the major part of furnace
enclosure.
TECHNICAL DATA
Design Temp & Pr. at WW
Inlet Hdr

3680C & 212 kg/cm2(g)

Design Temp & Pr. at WW


Outlet Hdr

3680C & 209 kg/cm2(g)

Total Heating Surface of WW


Tubes

7000 Sq.Mtr

Water Holding Capacity of


Circulating
System Ltd
Monnet
Power Company

170 m3
29

Description

Size
(DiaXThck)
(In mm)

Design Temp( 0C) Design Pressure


(kg/cm2(g))

Down Comer

368X36

368

212

Bottom Ring
Header

914X85

368

212

WW Tubes

51X5.6/6.0/7.1
63.5X7.1

396

214

Front, Hanger Tube


& Screen Tube O/L
Header

273X40

368

209

Side WW O/L
Header

273X50

368

209

Riser Pipes

159X18

368

209

Monnet Power Company Ltd

30

Plate
n SH

WW
Panel
s

Div
SH
Pan
el

Monnet Power Company Ltd

31

CC PUMP
Boiler water circulating pump is used in
high capacity boiler (Super critical or Sub
critical), It assists the circulation of water, to
overcome the friction losses in Boiler.
Make :
Torishima
Type :
Single Suction-Double discharge
No of Pumps :
Three
Design pressure :
210 kg/cm2(g)
Hydr0 test pressure : 315 kg/cm2(g)
Design Temperature : 366 oC
Motor Rating :
350 KW
Full Load Speed :
1450 rpm
Suction Pressure :
197kg/cm2(g)
Quantity Pumped : 48453 l/min(2850 tph)
Wt. of Motor :
7300 kg
Wt. of Pump casing :
5200 kg
Monnet Power Company Ltd

32

Riser
Riser
s
s

Saturated Steam Circuit


Sat Steam

DRUM

SH
SH Rear
Rear
Roof
Roof
Tubes
Tubes

Junctio
n Hdr

BP
BP
Upper
Upper
Rear
Rear
Wall
Wall

SH
Conn
Pipes

Rad
Rad
Roof
Roof I/L
I/L
Hdr
Hdr

Fur
Fur
Roof
Roof
Panel
Panel

SH
SH
Roof
Roof
O/L
O/L Hdr
Hdr

BP
BP L/R
L/R
Side
Side Upp
Upp
Hdr
Hdr

BP
BP
Front
Front
Wall
Wall

BP
BP
Front
Front
Lower
Lower
Hdr
Hdr

SH
SH BP
BP
Lower
Lower
Side
Side
Front
Front
Hdr
Hdr

BP
BP L/R
L/R
Side
Side
Wall
Wall
Panel
Panel

SH
SH
Rear
Rear
Hanger
Hanger
Tube
Tube

SH
SH
Rear
Rear
Int.
Int.
Hdr
Hdr

LTSH
I/L Hdr
Monnet Power Company Ltd

ECO
ECO
Support
Support
Tube
Tube

BP
BP
Lower
Lower
Rear
Rear
Wall
Wall

BP
BP
Lower
Lower
Rear
Rear
Hdr
Hdr

BP
BP
Lower
Lower
Side
Side
Rear
Rear
Hdr
Hdr
33

Saturated Steam Circulation System


Description

Size
(DiaXThick)
(In mm)

Design Temp
( 0C)

Design Pressure
(kg/cm2(g))

Rad Roof Inlet Header

273X50

369

208.8

Fur Roof Panel

57X6.0

414

208.8

Rad Roof O/L Hdr

406.4X55

369

208.2

BP L/R Side I/L. Hdr

368X48

368

208.0

BP L/R Side Panel

63.5X6.3/7.1.
51.0X5.0/5.6

393

208.0

SH BP Lower Side
Front Hdr

406.4X60

393

207.4

SH BP Front Lower Hdr

406.4X60

393

207.4

BP Front Wall

51X5.0/5.6
63.5/6.3

393

207.4

BP Front Hanger Tubes

51X6.3

394

207.4

Monnet Power Company Ltd

Contd..

34

Description

Size
(DiaXThck)
(In mm)

Design Temp
( 0C)

Design Pressure
(kg/cm2(g))

SH Rear Roof Panel

51X5

394

206.8

SH Rear Junction Hdr

273X50

395

206.7

BP Rear Upper Wall

51X5

395

206.7

BP Lower Side Rear Hdr

323.9X50

393

206.3

BP Lower Rear Hdr

323.9X45

393

206.3

BP Rear Lower Panel

44.5X5

394

206.3

ECO Support Tubes

44.5X7.1

393

207.4

SH Inter. Hdr

219.1X28

393

207.3

SH Hanger Tubes

51X11

394

207.2

Total Heating Surface of SH Roof 830 Sq Mtr


Total Heating Surface of Steam Cooled Wall 2010 Sq. Mtr
Monnet Power Company Ltd

35

Superheated Steam Circuit


LTSH
I/L Hdr

LTSH
Coil

LTSH
O/L Hdr

SH DESH
Link

Div SH
I/L Hdr

SH Vertical
Platen I/L
Hdr

SH Div
Panel O/L
Links

Div SH
O/L Hdr

SH Div
Panelette
Assy

MS Line

SH Vertical
Platen Assy

HP
Turbine

SH Platen
O/L Hdr

Monnet Power Company Ltd

MS Line

36

Super Heater System


O Superheater is a component of a boiler that superheats

steam i.e. heats steam above its saturation temperature.


Superheated steam contains more thermal energy and
increases the overall efficiency of the cycle.
O There are 3 stages of Super Heaters LTSH, Divisional
Panelette SH & Platen Super Heater.

TECHNICAL DATA
No of Sets

LTSH-62 Sets, Divisional


SH- 24 Sets, Platen SH 25
Sets

Total Heating Surface

LTSH -10,100 m2, Div SH


-2025 m2, Platen SH 2200
m2

Total Water Holding


Capacity of SH system

130 m3

Monnet Power Company Ltd

37

Superheater System

Description

Size
(DiaXThick)
(In mm)

Design Temp( 0C) Design Pressure


(kg/cm2(g))

LTSH I/L Hdr

323.9X50

395

205.8

LTSH Horizontal
Assy.

47.63X5.6

445

205.8

LTSH Terminal Tube


Assy

47.63X5.6

464

205.8

LTSH O/L Hdr

457.2x65

435

204.2

SH DESH Link

508x60
558x60

440
426

204.0

SH Div I/L Hdr

406.4X60

419

202.8

Monnet Power Company Ltd

Contd..

38

Description

Size
(DiaXThick)
(In mm)

Design Temp( 0C)

Design Pressure
(kg/cm2(g))

SH Div. Panelette
Assy

44.5X5
44.5X7.1

483/
522

202.8

Div. SH O/L Hdr

406.4X70

487

198.9

SH Div Panel O/L


Link

508X60

487

198.6

SH Vertical Platen
I/L Hdr

406.4X60

487

197.4

SH Vertical Platen
Assy

63.5X6.3/12
51X6.3/11

476/533
476/551

197.4

SH Platen O/L Hdr

508X110

540

192.2

Monnet Power Company Ltd

39

LTSH COIL

Monnet Power Company Ltd

40

Div SH Panel

Monnet Power Company Ltd

41

Platen SH

Monnet Power Company Ltd

42

Reheater Circuit
CRH
Line

From
HP
Turbin
e
Exhau
st

RH I/L
Hdr

RH Coil
Assy

IP
Turbin
e
Monnet Power Company Ltd

RH O/L Hdr
(F)
RH O/L Hdr (R)
HRH
Line

43

Reheater System
O Reheater is a boiler component in which heat is

added to intermediate-pressure steam, which


has lost some of its energy in expansion through
the high-pressure turbine.
O Reheater System comprises of : RH Inlet Header,
RH Front Platen Coil
Assy, DATA
RH Rear Spaced Assy,
TECHNICAL
RH
Outlet
Header
No of
RH Coil Assy
74 Sets (Both Front & Rear)
Total Heating Surface of RH Coils

7628 Sq. Mtr

Total Water Holding Capacity of RH

105 m3

Design Temp. & Pr. at RH Inlet Hdr

361 0C ,52.4 kg/cm2(g)

Design Temp. & Pr. at RH Outlet Hdr

540 0C,52.4 kg/cm2(g)

Size of RH front Coil Assy

63.5 mm Dia X 4 mm Thck


54 mm Dia X 4.5 mm Thck

Size of RH Rear Coil Assy

54 mm Dia X 4.5 mm Thck

Monnet Power Company Ltd

44

RH Coil Assy

Monnet Power Company Ltd

45

H.
R.
H

C.R.H

M.S

Boiler
Drum

Platen
SH

RH
Coil
Assy

DC

LTSH

CC
Pump

Div SH
ECO Coil

Furnace Wall
FROM F.C.S

WATER
SATURATED STEAM
SUPER HEATED STEAM

Monnet Power Company Ltd


Bottom Ring Header

46
REHEATED STEAM

Air Flow path


PA Fan

FD Fan

Col
d
PA
to
Mill

FD Fan

SCAPH
SCAPH

Pri.
Sid
e

Hot PA
to Mill

Flu
Flu
e
e
Gas
Gas

APH

Sec
Sid
e

Col
d
PA
to
Mill

SCAPH
SCAPH

Scann
er Air
fan

Wind Box
Monnet Power Company Ltd

PA Fan

Sec
.
Sid
e

Flu
Flu
e
e
Gas
Gas

APH

Pri.
Sid
e

Hot PA
to Mill

47

Forced Draught Fan


These fans supply air necessary for fuel combustion for

proper burning of the specific fuel. These are generally


axial type.
The FD fans supply secondary & over fire air, which is
preheated in secondary sector APH.
Over fire air can be admitted to the furnace through the
upper levels of furnace wind box nozzle to assist in
reducing the amount of NOx formed in furnace.
Control of airflow to WB is effected by FD fan blade pitch
control & distribution of secondary air to WB
compartments is controlled by secondary air damper.
Steam Coil Air Pre Heater(SCAPH) are provided in the by
pass ducts before each APH to prevent corrosion of cold
end of APH normally at start up & low load operation.
Monnet Power Company Ltd

48

Suction
Chamber

Blades

Forced Draught Fan

Monnet Power Company Ltd

Diffuser
49

Monnet Power Company Ltd

50

Primary air fan


These fans supply the air needed to dry & transport coal from

coal mills to the furnace. These fans are generally axial type of
fan.
To achieve the required temperature at mill inlets(For Proper
Drying of Coal) , part of air(Tempering air) by passes the APH &
is mixed with hot air coming out of APH.
The PA Fan blade pitch is modulated to maintain a pre

determined pressure in pulveriser hot air bus duct.


Mill Air flow is maintained by adjusting the hot air regulating

damper while the mill outlet temp is maintained by adjusting


the cold air regulator damper. Venturi is provided in the mill
inlet duct to measure the individual mill air flow.

Monnet Power Company Ltd

51

Suction
Chamber

Diffuser Assy.

Primary Air
Fan
Monnet
Power Company Ltd

52

1st
Stage
Blade
2nd
Stage
Blade

Primary Air Fan


Monnet Power Company Ltd

53

Technical specification of Fans


Description

Unit

PA Fan

FD Fan

Make

N.A.

BHEL

BHEL

Type

N.A.

PAF 19/10.6-2

FAF 23/12.5-1

Motor Rating

KW

3600

1200

Capacity

M3/Hr

105

215

Speed

rpm

1490

990

Pressure

mmwc

1290

410

Temp of
Medium
Handled

50

50

Bearing
Lubrication

N.A.

Oil
Lubrication(ISO
VG68)

Oil
Lubrication(ISO
VG68)

Monnet Power Company Ltd

54

Air Pre Heater

The purpose of APH is to recover heat from

the boiler flue gas & heat air before another


process and so as to increase the thermal
efficiency.
Ljungstrom (Regenerative) Air Pre Heater:
The basic component of Ljungstrom APH is a

continuously rotating cylinder, called rotor, that is


packed with thousands of square feet of specially
formed sheets of heat transfer surface.
As the Rotor revolves, waste heat is absorbed
from the hot flue gas passing through one half of
the structure. The heat transfer cycle is
continuous as the surface are alternatively
Monnet Power Company Ltd
55
exposed to the outgoing gas & incoming air

Monnet Power Company Ltd

56

Technical Data
Description

Value

Type

Regenerative, Trisector

No per Boiler

Two

Rotor Diameter

6789 mm

Arrangement

Vertical

Heating Surface Area

84200 M2

Main Drive

18.5 KW,1500 rpm

Aux. Drive

Air Motor with gear box & muffler, Air


consumption 8 Nm3/min at pressure 6.33
kg/cm2(g)

Monnet Power Company Ltd

57

Soot blowers
As the flue gas moves over the heat transfer

areas of boiler, the ash deposits on the


heating surfaces. This is known as soot
deposit. Soot Blowers are installed to blow
away these soot deposits to facilitate smooth
heat transfer.
There are two types of Soot Blowers-Wall
Blowers & Long Retractable Soot Blowers.
Wall Blowers are used to blow off soots
deposited in water walls in furnace
LRSB are used in Super Heaters, Economiser
& Reheater Zone.
Monnet Power Company Ltd

58

WALL
BLOWER

LRSB
Monnet Power Company Ltd

59

WALL BLOWER
Monnet Power Company Ltd

60

Technical Data
Description

Unit

Wall Blower

LRSB

No per Boiler

No.

88+16(Future)

40+18(Future)

Travel

mm

305

9700

Blowing Pressure

kg/cm2(g)

11

12.5/10.5

Blowing Steam Temp

383

383

Speed of Travel

mpm

6.1

1.55

Speed of Rotary

rpm

0.7

5.87

Blowing Rate per group

Kg/min

89

152/93/79

Blowing time per group

Min

1.4

12.04

Operating time per cycle

Min

66

75.12/325.52/100
.16

Steam Consumption per


cycle

Kg

5500

47708

Steam Consumption
/Cycle/Blower

Kg

62.5

1192

Total Steam Consumption per Day

Kg

Blowing Steam Temp &


Pr.
Cycles per Day

Monnet Power
No Company Ltd
3

159624
383 0C & 30 kg/cm2
3

61

14 kg/cm2(g)
250 0C

LDO & HFO Circuit

PRS
PRS

LDO cap.50m3/hr & Pr.- 2


Kg/cm2

HFO cap.HFO
50m3/hr & Pr.- 5
Pump
Kg/cm2
s

LDO
Pump
s

Unloadin
g Pump
House

4.5 kg/cm2(g)
232 0C

Tanker
Tanker 1
1
12KL
12KL
Tanker
Tanker 2
2
12KL
12KL
Tanker
Tanker 3
3
12KL
12KL

HFO
HFO
Tank
Tank #1
#1
3000
3000
3
m
m3

HFO
HFO
Tank
Tank #2
#2
3000
3000
3
m
m3

LDO
LDO
Tank#
Tank#
1
1
1000
1000
3
m
m3

LDO
LDO
Tank#
Tank#
2
2
1000
1000
3
m
m3

Contd
..

Tanker
Tanker 4
4
12KL
12KL
Tanker
Tanker 5
5
12KL
12KL
Tanker
Tanker 6
6
12KL
12KL

Monnet Power Condensate


Company LtdLine to Flash

LDO Unloading
Header
HFO Unloading
Header
LDO Discharge Line
HFO Discharge 62
Line

LDO & HFO Circuit


LDO
LDO
Tan
Tan
k
k

2X1000
m3

HFO
HFO
Tank
Tank
2X3000
m3

1x100
LDO
LDO
%
Pump
Pump
Set(Both
Set(Both
Units)
Units)

Forwarding Pump
House

HFO
HFO
Pump
Pump
Set(Unit
Set(Unit
I)
2x100
I)

Boiler
I

Boiler
II

%
HFO
HFO
Pump
Pump
Set(Unit
Set(Unit
II)
II)
HFO
HFO
Heater-1
Heater-1
Steam
Tracin
g Line

HFO
HFO
Heater-2
Heater-2

HFO
HFO
Drain
Drain
System
System

14
kg/cm2(g)
210 0C

Monnet Power Company Ltd

Steam
Tracin
g Line

Aux.
Steam

Condensate Line
63
to Nearest Trench

Technical specification of hfo & Ldo


Description

Unit

LDO

HFO

Standard

N.A.

IS 1460-1974

IS-1593/1971/Gr
HV/Oil

Flash Point

66

66

Pumping Temp.

35

55

Firing Temp.

35

120

Viscosity

cst

2 to 20 @Firing
Temp.

180 at 55 0C

Total Sulphur

N.A.

1.8 % by
weight

4.5 % by weight

GCV

Kcal/kg

10720

10270

Sp. Gravity at
15 0C

N.A.

0.85-0.87

0.85-0.95

Monnet Power Company Ltd

64

Technical specification of HFO & LDO Forwarding Pumps


Description

Unit

LDO Pump

HFO Pump

Make

N.A.

Alekton

Alekton

No of Pump per Blr

No

01(Common for 01
Both Unit)

Model No.

N.A.

DH 330-770-3

DH 600-1400-3
SJ

Capacity at max cst

lpm

281(14.3 tph)

879(50.1 tph)

Speed

rpm

2920

1450

Suction Pressure

kg/cm2(g) -0.5

-0.5

Delivery Pressure

kg/cm2(g) 25

30

Motor rating

KW

18.5

75

Motor Make

N.A.

Crompton
Greaves

Crompton
Greaves

Bearing Lubrication

N.A.

Grease IS 719
Gr.3

Grease IS 719
Gr.3

Pump Efficiency(at min


%
78
Monnet Power Company Ltd
cst)

83.7

65

TT burners assy.
OVER FIRE AIR
UPPER

HFO OIL BURNERS

OVER FIRE AIR


LOWER

HH
H

END
END
AIR
AIR

COAL
COAL
OIL+AI
OIL+AI
R
R
COAL
COAL

FG

AIR
AIR

COAL
COAL
OIL+AI
OIL+AI
R
R
COAL
COAL

DE

AIR
AIR

COAL
COAL
OIL+AI
OIL+AI
R
R
COAL
COAL

BC

AIR
AIR

COAL
COAL
OIL+AI
OIL+AI
R
R
COAL
COAL

GH

EF

CD

AB
A
AA

END
END
AIR
AIR

Service

Ignition of Pulverised Fuel, Stabilization


of Coal Flame at lower loads etc.

Capacity Maximum

30 % MCR

No of Oil Guns

16(4 per elevation)

Locations

Aux air nozzles AB,CD,EF & GH

HFO flow per Gun

2420 kg/hr(Max), 950 kg/hr(Min)

HFO Pressure

10.5 kg/cm2(g)(Max), 4.0 kg/cm2(g)


(Min)

Atm. Steam Flow/Gun

250 kg/Hr

At. Steam Pr.

5.25 kg/cm2(g)

LDO OIL BURNERS


Service

Initial startup & warm-up.

Capacity Maximum

7.5 % MCR

No of Oil Guns

4(In One Elevation)

Locations

Aux air nozzle AB

LDO flow per Gun

2420 kg/hr(Max), 950 kg/hr(Min)

LDO Pressure

10.0 kg/cm2(g)(Max), 3.5 kg/cm2(g)


(Min)

Atm. air Flow/Gun

241 kg/ Hr

At. air Pr.

5.25 kg/cm2(g)

Monnet Power Company Ltd

66

Coal Circuit
Coal
From
CHP

To
four
corne
rs of
Boiler

Coal
Bunke
r

Feeder

Pulveriser
Pulveriser

Monnet Power Company Ltd

67

Flue gas path

1404
0
C
Combusti
Combusti
on
on
Chamber
Chamber

1150
0
C

1040
0
C

Plate
n SH

Div
SH

904
0
C

7100C

RH
Coil

LTSH
Coil

ESP
ESP
Pass
Pass A
A

3340C
541
0
C

APH

1270C

ID
ID
Fa
Fa
n
n

ESP
ESP
Pass
Pass B
B

Economise
r

ESP
ESP
Pass
Pass C
C

3340C

APH

ID
ID
Fa
Fa
n
n

127
0
C

Monnet Power Company Ltd

C
H
I
M
N
E
Y

ESP
ESP
Pass
Pass D
D

68

Flue Gas Path

-19 mmwc

-33 mmwc

-79
mmwc

-5 mmwc

ESP
-213
mmwc

-270
+32
mmwc mmwc

APH

Monnet Power Company Ltd

69

C
H
I
M
N
E
Y

Electrostatic Precipitator : Anelectrostatic

precipitator(ESP) is a highly efficient filtration


device that removes fine particles, like dust and
smoke, from a flowing gas using the force of an
induced electrostatic charge minimally impeding
the flow of gases through the unit.
No of pass per boiler : 4
Gas flow at inlet : 566.7 Nm 3/s
Temp. at inlet : 127 0C
Dust concentration at inlet : 86.8 gm/Nm 3 (Worst

Coal), 70.69 gm/Nm3 (Design Coal)


Dust concentration at outlet : 50 mg/Nm 3(Worst
Coal)
Efficiency : 99.942 %
Monnet Power Company Ltd

70

Induced Draught Fan : ID Fans evacuate

combustion products from the boiler furnace by


creating sufficient negative pressure to establish
a slight suction in furnace.
Make : BHEL
No per Boiler : Two
Model No. - NDZV 47 SIDOR
Fan Regulation : Inlet damper & VFD
Temp. of Medium : 150 0C
Motor Rating : 3800 KW
Flow : 565 m3/Hr
Draught at Inlet : -270 mmwc
Draught at Outlet : 32 mmwc
Bearing Lubrication : Oil Lubrication(ISO VG68)
Monnet Power Company Ltd

71

INDUCED DRAUGHT FAN

Suction
Chambe
r
Motor

Rear
Side
Bearin
g

Monnet Power Company Ltd

Discharge
Chamber

Front
Side
Bearin
g
Impelle
r
72

Thanks
Monnet Power Company Ltd