Hospital Design
Hospital Design
Dr A PRAKASH
Sr. Professor, Health Management
National Academy of Indian Railways
(Formerly Railway Staff College)
VADODARA 390 004
Dutch architectural historian Cor Wagenaar has
called many hospitals:
"... built catastrophes, anonymous institutional
complexes run by vast bureaucracies, and totally
unfit for the purpose they have been designed
for ... They are hardly ever functional, and instead
of making patients feel at home, they produce
stress and anxiety."
The research of British Medical Association
shows that good hospital design can reduce
patient's recovery time.
Free access
Maintenance free
Environment friendly
Functional segregation
Disabled friendly
National Building Code
FLOOR AREA OF HOSPITAL
OPD 12%-18%
Wards 37%-45%
Administration 8%-12%
Nursing 250-280
Nursery 12-18
OT 30-50
Radiology 25-35
Laboratory 25-35
Pharmacy - 4-6
FLOOR AREA
DETAILED BREAKUP
CSSD 8-25
Dietary 25-35
Laundary 12-18
Stores - 25-35
FLOOR AREA
DETAILED BREAKUP
Administration 40-50
Circulation 115-140
TOTAL 681-991
Up to 60 one
Up to 200 two
Up to 350 three
Size >2280X1600X2300 mm
with door size >1300X2100 mm
OPD
Easy access
Waiting area
WARDS
24 to 32 beded
Broom closet 40 sq ft
MGPS
WINDOWS IN WARDS
Medical 30%-40%
Surgical 25%-30%
Peadiatrics 10%-12%
MGPS
Monitor cabling
OT THE NUMBER
50 0 1 0 1
100 1 1 0 1
300 2 3 0 1
500 2 5 1 1
750 2 8 1 1
1000 2 10 1 1
ZONING IN OT
Protective Zone
Clean Zone
Sterile Zone
Temperature 20+2
Scrub Room 80 sq ft
Plaster Room 80 sq ft
Anaesthesia Store 80 sq ft
OT Office 120 sq ft
OT FLOOR AREA DISTRIBUTION
Trolley Bay 80 sq ft
Safaiwala Alcove 80 sq ft
OT FLOOR AREA DISTRIBUTION
Electricity Clean
MGPS
? SEAMLESS / MODULAR OT
LABOUR ROOMS
Lighting
MGPS
Natural Light
MORTUARY
Cold Room
Waiting Area
PROVISION FOR GROWTH
Dilution
CO2 / Heat Load / Microbial Load
Humidity Control
Air Purification
Filters / UV / Ozone
AIRCONDITIONING
Integration of
Ventilation
Lighting
Fire fighting
MGPS
Cabling for computers & monitors etc
AC OT
Temp 20-23
RH 50%- 60%
Temp 20-23
RH 30%-60%
Pressure Negative
Air filtration 20
Temp 21-24
RH 30%-60%
Pressure Positive
Air Filtration 5
AC MICU/SICU
Temp 21-24
RH 30%-60%
Pressure Positive
Air Filtration 5
LABOUR ROOM
Temp 20-23
RH 30%-60%
Pressure Positive
Air Filtration 5
NURSERY
Temp 22-26
RH 30%-60%
Pressure Positive
Air Filtration 5
WARDS
Temp 21-24
RH 30%-60%
Pressure Positive
Air Filtration 20
Temp 24
RH 30%-60%
Pressure Negative
Temp 24
RH 30%-60%