PCS-996 DFR: NR Electric Co., LTD
PCS-996 DFR: NR Electric Co., LTD
PCS-996 DFR
UPLINK
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Station 1 Station n
Local DFR HMI Local DFR HMI
UPLINK UPLINK
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
www.nrelect.com 2
Hardware 3
• Front view
HEALTHY PCS-996
ALARM DISTURBANCE&FAULT RECORDER
REC
C GRP
ENT
ES
www.nrelect.com 3
Hardware 4
• Rear View
NR1102J NR1156A NR1401 NR1401 NR1401 NR1504 NR1504 NR1504 NR1504 NR1504 NR1102J NR1301
1 2 3 5V OK ALM
TX TX
RX RX BO_ALM BO_FAIL
4 5 6
TX TX
RX RX
1 BO_COM1
DANGER DANGER DANGER 2 BO_FAIL
3 BO_ALM
4 BO_COM2
5 BO_FAIL
6 BO_ALM
7 OPTO+
8 OPTO-
10 PWR+
11 PWR-
12 GND
www.nrelect.com 4
Hardware 5
• 36 AI, 90 BI
• 36 AI, 84 BI, 4 BO
• 48 AI, 54 BI
• 48 AI, 48 BI, 4 BO
• 24AI, 126 BI
www.nrelect.com 5
Hardware 6
• AI module
1401 1401 1401
I1 01 I1n 02 U1 01 U1n 02 I1 01 I1n 02
www.nrelect.com 6
Hardware 7
• BI module
-KM +KM
1504
01 Opto +
02 Binary input 01
03 Binary input 02
04 Binary input 03
05 Binary input 04
06 Binary input 05
07 Binary input 06
08 COM1 -
09 Binary input 07
10 Binary input 08
11 Binary input 09
12 Binary input 10
13 Binary input 11
14 Binary input 12
15 COM2 -
16 Binary input 13
17 Binary input 14
18 Binary input 15
19 Binary input 16
20 Binary input 17
21 Binary input 18
22 COM3 - www.nrelect.com 7
Hardware 8
• BO module
-KM +KM 1525
01 Binary
output 01
02
03 Binary
output 02
04
05 Binary
output 03
06
07 Binary
output 04
08
09 Binary input 01
10 Binary input 02
11 Binary input 03
12 Binary input 04
13 Binary input 05
14 Binary input 06
15 Binary input 07
16 Binary input 08
17 Binary input 09
18 Binary input 10
19 Binary input 11
20 Binary input 12
21 OPTO+
22 OPTO-
www.nrelect.com 8
Hardware 9
• CPU module
NR1102J
TX
RX
TX
RX
www.nrelect.com 9
Operation Theory 10
• 4 Triggering conditions
Triggered by voltage
www.nrelect.com 10
Operation Theory 11
Triggered by current
www.nrelect.com 11
Operation Theory 12
Manual trigger
www.nrelect.com 12
Operation Theory 13
A B C
S T
www.nrelect.com 13
Operation Theory 14
www.nrelect.com 14
Operation Theory 15
• Storage of records
Triggered records and continuous records store in the local CF card. If
space expires, the eldest data will be covered by latest data.
Capacity: 16/128G. More than 30,00 records for trigger , 7 days for
continuous, 6 months for slow records, which can meet the
requirement of DFR for the whole lifecycle
www.nrelect.com 15
Operation Theory 16
• Analyze Functions
The recorder can analyze the fault line, fault type, fault phase, fault
location, etc, in real time
www.nrelect.com 16
PCS-996 17
www.nrelect.com 17
PCS-996 18
www.nrelect.com 18
PCS-996 19
• Harmonic analysis
www.nrelect.com 19
PCS-996 20
www.nrelect.com 20
Content 21
• Application
• Hardware
• Operation theory
• Communication
www.nrelect.com 21
Communication 22
• Ethernet communication
SCADA
Switch
Switch
www.nrelect.com 22
Thanks for Your Attention!
www.nrelect.com
Version 2012