This document describes new functions for 4th generation indoor units when combined with other indoor and outdoor units. It lists functions such as showing filter signs on the central controller, energy monitoring on remote controllers, auto temperature changeover controlled by the central controller, and refrigerant leakage detection. Functions are categorized as fully usable, partially usable, or not usable depending on the combination of indoor and outdoor units. An example combination case shows which new functions would be fully usable when pairing a 4th generation indoor unit with a Multi V IV outdoor unit.
This document describes new functions for 4th generation indoor units when combined with other indoor and outdoor units. It lists functions such as showing filter signs on the central controller, energy monitoring on remote controllers, auto temperature changeover controlled by the central controller, and refrigerant leakage detection. Functions are categorized as fully usable, partially usable, or not usable depending on the combination of indoor and outdoor units. An example combination case shows which new functions would be fully usable when pairing a 4th generation indoor unit with a Multi V IV outdoor unit.
This document describes new functions for 4th generation indoor units when combined with other indoor and outdoor units. It lists functions such as showing filter signs on the central controller, energy monitoring on remote controllers, auto temperature changeover controlled by the central controller, and refrigerant leakage detection. Functions are categorized as fully usable, partially usable, or not usable depending on the combination of indoor and outdoor units. An example combination case shows which new functions would be fully usable when pairing a 4th generation indoor unit with a Multi V IV outdoor unit.
Remote Controller Central Controller Premium Standard Combination Function Description of new function for 4 Gen. ACS IV PREMTB10U PREMTB001 PREMTB100 Simple ACM IV PREMTA000 ACP IV (N/America) (RS2+) (developing) Filter Sign at central show and remove filter sign in not only remote controller - - - - X ● ● controller but also central controller can monitor energy usage in not only central controller X X Energy Monitoring ● ● ● ● ● but also remote controller. (No icon) (No icon) 2 Set Points auto Set the 2 set temperature (cooling/heating) with central X X Partially ● ● ● ● X changeover [New] controller and remote controller. (No icon) (No icon) usable 1) Occupied / Unoccupied This function can be controlled by remote controller and X X Scheduling Function central controller, synchronized with them ● ● ● ● X (No icon) (No icon) [New] Refrigerant Leakage Error sign in case of refrigerant leakage ● ● ● ● X - - Detection [New] Additional functions Additional functions in group control ● ● ● ● X - - with Group Control - Same type indoor unit must be in group. Heating test run mode Heating test run mode can be used in individual unit. ● ● ● ● X - - [New] Model Information Checking Outdoor unit, indoor unit and indoor unit’s X ● ● ● X - - Monitoring [New] capacity in wired remote controller (No icon) Address of indoor units can be monitored not only in Address Monitoring ● ● ● ● X - - LGMV but also in R/Controller Thermo On/Off Range Setting cooling thermo on/off range ● ● ● ● X - - Setting (Cooling) [New] Fully Thermo On/Off Range Setting heating thermo on/off range (4 step) ● ● ● ● ● - - Usable Setting (Heating) (4step) (4step) (3step) (4step) (3step) Static Pressure 11 Static pressure can be set by choosing only function code ● ● ● ● ● - - Step Control [New] with R/Controller Control to operate Ceiling concealed duct with wireless IR RECEIVER [New] - - - - - - - remote controller (for India/EU) 1 Point External input On/Off control by dry contact at CCD, CST/RAC IDU ● ● ● X X - - (On/Off control) [New] (CN-CC) (CN-CC) (CN-CC) Filter Sign The remaining time of filter cleansing display in ● ● ● ● X - - (Remaining Time) R/controller. Auto restart function Enable : stand-by with off mode after auto restart. ● ● ● ● X - - (Disable / Enable) Disable : previous mode operation after auto restart. 1200 bps 9600 bps 1) Gen.4 IDU can operate this function with combination of all 9600 bps units. IDU 2 Gen. 4 Gen. Multi V IV (15.3~) Multi V PRO (15.3~) ODU The others Example of combination case Multi V Water IV (15.3~) Multi V S (15.7~) ■ New Function list for 4 Gen. IDU by Combination of IDU and ODU (example of combination) Case1 : Fully usable Combination Function Description of new function for 4 Gen. Case1 Case2 Case3 show and remove filter sign in not only remote 4 Gen. Filter Sign at central controller controller but also central controller O X X
can monitor energy usage in not only central
Energy Monitoring controller but also remote controller. O X X 4 Gen. Partially 2 Set Points auto changeover Set the 2 set temperature (cooling/heating) with O X X Multi V IV usable 1) (EU/North America) central controller and remote controller. 4 Gen. This function can be controlled by remote Occupied / Unoccupied controller and central controller, synchronized O X X Scheduling Function with them 4 Gen. Refrigerant Leakage Detection Error sign in case of refrigerant leakage O X X Additional functions with Group Additional functions in group control - Same type indoor unit must be in group. O O O Case2 : Partially usable Control Heating test run mode can be used in individual Heating test run mode unit. O O O 2 Gen. Checking Outdoor unit, indoor unit and indoor Model Information Monitoring unit’s capacity in wired remote controller O O O 2 Gen. Address of indoor units can be monitored not Address Monitoring only in LGMV but also in R/Controller O O O Multi V PRO Thermo On/Off Range Setting Setting cooling thermo on/off range 4 Gen. O O O (Cooling) Thermo On/Off Range Setting Setting heating thermo on/off range (4 step) Fully O O O 4 Gen. (Heating) Usable Static pressure can be set by choosing only Static Pressure 11 Step function code O O O Case3 : Partially usable Control with R/Controller Control to operate Ceiling concealed duct with 4 Gen. IR RECEIVER wireless remote controller (for India/EU) O O O
1 Point External input(On/Off On/Off control by dry contact at CCD, CST/RAC
IDU O O O 4 Gen. control) Filter Sign The remaining time of filter cleansing display in Multi V III R/controller. O O O (Remaining Time) 4 Gen. Enable : stand by of off mode after auto restart. Auto restart function (Disable / Disable : previous mode operation after auto O O O Enable) restart. 4 Gen.
: the model which function can be applied in table