SITE CIRCULATION
• EXTERNAL
1. APPROACHING ROADS

• INTERNAL
1. INTERNAL ROADS
THE AREA LIMITS SHALL APPLY TO ALL BUILDINGS FRONTING ON A STREET OR PUBLIC SPACE NOT LESS
THAN 9 M IN WIDTH ACCESSIBLE TO A PUBLIC STREET.

2. PEDESTRAIN PATHWAYS
THE APPROACH TO THE BUILDINGS FROM ROAD/STREET/INTERNAL MEANS OF ACCESS SHALL BE THROUGH
PAVED PATHWAY OF WIDTH NOT LESS THAN 1.5 M, PROVIDED ITS LENGTH IS NOT MORE THAN 30 M.

CAMPUS DEVELOPMENT
DISTRICT ADMINISTRATIVE COMPLEX
PARKING

50 percent of the open spaces required


around the building may be allowed to be
utilized for parking, provided a minimum
distance of 3.6 m around the building is
kept free from any parking.
• For car, 3x6 m for individual parking and
2.75x5m when common parking space is
required.
• Space for scooter and bicycle to be not
less than 1.25m2 and 1.00m2 respectively.
ECS (Equivalent Car Space)inclusive of
parking:
• 23 m2 for open parking
• 28m2 for ground floor covered parking
• 32m2 for basement

CAMPUS DEVELOPMENT
DISTRICT ADMINISTRATIVE COMPLEX
PARKING

CAMPUS DEVELOPMENT
DISTRICT ADMINISTRATIVE COMPLEX
PARKING

CAMPUS DEVELOPMENT
DISTRICT ADMINISTRATIVE COMPLEX
LANSCAPING
• THE LANDSCAPE TREATMENT OF THE MAJOR TRAFFIC ARTERIES THAT BORDER THE
CAMPUS SHALL FORM THE BASIS FOR THE CAMPUS EDGE AND ESTABLISH OVERALL
IMAGERY. WITHIN THIS CONTEXT, LANDSCAPE TREATMENT SHALL VARY DEPENDING ON
ABUTTING USES ON THE CAMPUS EDGE.
• COMMON ELEMENTS THE FOLLOWING CHARACTERISTICS:
1. A CONSISTENT STREET TREE PLANTING WITH DESIGNATED TREES AND SPACING.
2. PEDESTRIAN WALKWAYS ALONG ONE OR BOTH SIDES.
3. PEDESTRIAN CROSSWALKS ARTICULATED AT KEY INTERSECTIONS WITH SPECIAL
PAVING.
4. THE GROUND PLANE SHALL BE PREDOMINANTLY SODDED LAWN AREAS WITH THE
EXCEPTION OF LOW MAINTENANCE GROUNDCOVER AT SPECIAL INTERSECTIONS OR
ENTRANCES.
5. CONSIDERATION SHALL BE GIVEN FOR ARTICULATION OF FINE GRADING AND
MOUNDING OF LANDFORMS.
6. ISLANDS IN THE BOULEVARDS AND SIDE VERGES SHALL BE BERMED OR SLOPED FOR
AESTHETIC OR FUNCTIONAL PURPOSES.
7. SIGNS AND WAYFINDING INFORMATION SHALL BE COORDINATED WITH LANDSCAPE
TREATMENT AND LOCATION.

CAMPUS DEVELOPMENT
DISTRICT ADMINISTRATIVE COMPLEX
LANSCAPING

• THE VEHICULAR ENTRANCES TO THE


CAMPUS, THE LANDSCAPE EDGE SHALL OPEN
UP OR REINFORCE VIEW PENETRATION INTO
CAMPUS.
• BOUNDARY MONUMENTS, GATEWAYS, SIGNS
AND OTHER ARCHITECTURAL FEATURES SHALL
BE USED TO REINFORCE THE CAMPUS EDGE.

CAMPUS DEVELOPMENT
DISTRICT ADMINISTRATIVE COMPLEX
LANSCAPING
A GRAPHICS AND SIGNAGE
STUDY SHALL BE CONDUCTED
TO ESTABLISH THEME AND
HIERARCHY FOR ALL CAMPUS
GRAPHICS AND SIGNAGE. THE
GRAPHICS AND SIGNAGE
STUDY SHALL CONSIDER ALL
ASPECTS OF SIGNAGE ON
CAMPUS, FROM MAJOR
ENTRY SIGNS, OFF-SITE
DIRECTIONAL SIGNS, WAY-
FINDING, PARKING LOT,
BUILDING IDENTIFICATION,
AND CAMPUS MAP
DIRECTORY SIGNAGE.

CAMPUS DEVELOPMENT
DISTRICT ADMINISTRATIVE COMPLEX
WATER SUPPLY

BUILDING SERVICES
DISTRICT ADMINISTRATIVE COMPLEX
SANITATION

BUILDING SERVICES
DISTRICT ADMINISTRATIVE COMPLEX
SANITATION

BUILDING SERVICES
DISTRICT ADMINISTRATIVE COMPLEX
H.V.A.C.

BUILDING SERVICES
DISTRICT ADMINISTRATIVE COMPLEX
FIRE FIGHTING
THE MANUAL CALL POINTS SHALL BE PROVIDED ON EVERY
STOREY OF THE BUILDING OR PART OF THE BUILDING AND
SHALL BE SO LOCATED THAT NO PERSON NEED TRAVEL MORE
THAN 30M FROM ANY POSITION WITHIN THE BUILDING TO
ACTIVATE THE ALARM.

PORTABLE FIRE EXTINGUISHERS PROVIDED SHALL


BE INSTALLED AND CONSPICUOUSLY MARKED IN
ACCORDANCE WITH REQUIREMENTS.

BUILDING SERVICES
DISTRICT ADMINISTRATIVE COMPLEX
FIRE FIGHTING

DRY RISING MAIN (DRY RISER). A VERTICAL


PIPE INSTALLED IN A BUILDING FOR FIRE
FIGHTING PURPOSES, FITTED WITH INLET
CONNECTIONS AT FIRE ENGINE ACCESS
LEVEL AND LANDING VALVES ON VARIOUS
FLOORS, WHICH IS NORMALLY DRY BUT IS
CAPABLE OF BEING CHARGED WITH
WATER USUALLY BY PUMPING FROM FIRE
ENGINE PUMPS.
BUILDING SERVICES
DISTRICT ADMINISTRATIVE COMPLEX
FIRE FIGHTING
WET RISING MAIN (WET RISER): A VERTICAL
PIPE INSTALLED IN A BUILDING FOR FIRE
FIGHTING PURPOSES AND PERMANENTLY
CHARGED WITH WATER FROM A
PRESSURIZED SUPPLY, AND FITTED
WITH LANDING VALVES ON VARIOUS FLOORS.

BUILDING SERVICES
DISTRICT ADMINISTRATIVE COMPLEX
ENTRANCE
• A RAMP WHEN PROVIDED
SHOULD NOT HAVE A SLOPE
GREATER THAN 1 IN 20 OR
MAXIMUM OF 1 IN 12 FOR SHORT
DISTANCE UP TO 9000 MM.
• A RAMP SHALL HAVE
HANDRAILS ON AT LEAST ONE
SIDE, AND PREFERABLY TWO
SIDES, THAT ARE 900 MM HIGH,
MEASURED FROM THE SURFACE
OF THE RAMP, THAT ARE
SMOOTH,AND THAT EXTEND 300
MM BEYOND THE TOP AND
BOTTOM OF THE RAMP.

INTERNAL CIRCULATION & PLANNING


DISTRICT ADMINISTRATIVE COMPLEX
WORK STATIONS

INTERNAL CIRCULATION & PLANNING


DISTRICT ADMINISTRATIVE COMPLEX
WORK STATIONS

BASIC WORKSTATION WITH


VISITOR’S SEATING.

INTERNAL CIRCULATION & PLANNING


DISTRICT ADMINISTRATIVE COMPLEX
WORK STATIONS

INTERNAL CIRCULATION & PLANNING


DISTRICT ADMINISTRATIVE COMPLEX
WORK STATIONS

BASIC WORKSTATION FOR


RECEPTION.

INTERNAL CIRCULATION & PLANNING


DISTRICT ADMINISTRATIVE COMPLEX
LIGHTING

INTERNAL CIRCULATION & PLANNING


DISTRICT ADMINISTRATIVE COMPLEX
STRUCTURE PLANNING

INTERNAL CIRCULATION & PLANNING


DISTRICT ADMINISTRATIVE COMPLEX
STAIRCASE
INTERNAL STAIRCASE SHALL BE CONSTRUCTED OF NON COMBUSTIBLE MATERIAL
THROUGHOUT.
THE MAIN AND EXTERNAL STAIRCASE SHALL BE CONTINUOUS FROM GROUND FLOOR TO
THE TERRACE LEVEL.
MINIMUM WIDTH OF STAIRS – 1.5 M
MINIMUM TREAD – 300 MM
MINIMUM RISER – 150 MM; THESE SHALL BE LIMITED TO 12 PER FLIGHT
MINIMUM HEAD-ROOM SHALL BE 2.2 M
HANDRAILS SHALL BE PROVIDED AT A HEIGHT OF 1000MM.

INTERNAL CIRCULATION & PLANNING


DISTRICT ADMINISTRATIVE COMPLEX
LIFTS

RECOMMENDED
DIMENSIONS OF
PASSENGER LIFTS

INTERNAL CIRCULATION & PLANNING


DISTRICT ADMINISTRATIVE COMPLEX
ESCALATORS

INTERNAL CIRCULATION & PLANNING


DISTRICT ADMINISTRATIVE COMPLEX

GMADA
SITE COVERAGE Shall not exceed 40% of the total area of the site

FLOOR AREA RATIO The maximum F.A.R shall not exceed 1.5

HT. OF THE BUILDING •The maximum height up to which any building be built shall not
AND SETBACK exceed the width of abutting road or street plus the width of the
set back
• The width of front and rear set backs, if left at any point of the
building, shall be equal to 1/4th of the height of the building
subject to a min. Of 2m and the width of the side set back if left
at any point of the building shall be equal to 1/5th of the height
of the building subject to minimum of 1.5 m.
PROJECTION •An uncovered balcony or chhajja or cantilever , shall not project
more than 2m beyond the building line when measured at right
angle to the outer face of the wall.
•The projection on Doors and Windows shall not exceed 0.45 m.
•No projection shall be at a lesser height than 2.25 m clear
above the plinth level.

BUILDING BYE-LAWS
DISTRICT ADMINISTRATIVE COMPLEX

GMADA
PARKING •The total parking area shall not be less than 10% of the area of
site + 10% of the total covered area on all the floors.

BASEMENT • The min. Clear height of the basement should be 2.5m.

STAIRCASE • At least one staircase extending from ground floor level to the
highest floor having minimum clear width of 1.20 meter shall be
provided.

• No staircase shall have riser if more than 22 cm and a tread of


less than 23 cm.

• The width of the landing shall not be less than the width of
staircase.

• The clear headroom in any case shall not be less than 2.25
meters.

BUILDING BYE-LAWS
DISTRICT ADMINISTRATIVE COMPLEX

GMADA
MINIMUM HEIGHT OF • The height of a habitable room shall not be less than 2.70 m.

ROOM
LIGHT AND • Ventilators glazed doors or other apertures shall not be less than
1/10th of the floor area of the room .
VENTILATION
PROVISION OF LIFT • Every building having more than 14m height shall be provided with
in a minimum of one lift and the total number of such lifts be
calculated on the basis of one lift for every 900 square meter floor
area above 4 storeys.