Automatic Fire Detection & Suppression Systems

Company Intro
• KANADIA FYR FYTER PRIVATE LIMITED in a brand
name of KANEX is a company which manufacturers all types
of fire extinguishers & Fire Suppression System It is one of the
most respected companies in India .

• Kanex completed its first decade with a strong, customer


centric approach in its operations and the continuous quest for
World Class Quality has enabled us to attain & sustain
leadership in the Fire Protection Industry.

• Our business is supported by innovative marketing activities,


wide distribution network and has established a reputation for
strong customer support.
Presence All over India

• MUMBAI
• NOIDA
• KOLKATA
• CHENNAI
• AHMEDABAD
• BHAVNAGAR
• HYDERABAD
• BENGALURU
• PUNE
• BANGALORE

Presence at - PAN INDIA


Why systems required ?

National Building Code Of India. Part 4 Fire And


Life Safety (2016)
As per Clause – 3.4.6.3
What we do

Critical Asset Protection


 Kanex Systems protects high value assets and
processes from fire.
 Supplemental to other system types
 Prevent Loss & Downtime
 Ensure Process and Business Continuity
 By detecting and extinguishing fire at its
source……
Unlike other solutions we do not total floor rooms/spaces,
which has its value too, but kanex protects:
 “Micro-Enclosures”
 Individual Pieces of Equipment
 Enclosed and Unenclosed Hazards.
Totally Unique.
– Pre-engineered. Self Contained
– No Hydraulic Calculations, Multiple/pinpoint Detection
– Design Principles Stated in Product System Manuals
In-Cabinet
Level Fire
Protection
Room Level Fire
Protection

Building Level Fire


Protection

In-Cabinet Level Protection


Detection Tube is
pressurised

Heat from the fire softens the


tube and causes it to “burst”

This hole forms a nozzle


to deliver the agent

Agent is released directly on


to the hottest part of the fire
DLP System – Server Rack

Protect each
Rack on an
individual basis

Server Rack Application


Protect a group of
Server rack with one
system
TYPICAL APPLICATIONS IN
BUILDINGS,DATA CENTRES

• Electrical Control Centre


• HVAC Panels, AHU’s
• Server racks
• Lifts & Escalator Panels
• UPS Systems
• Power Vaults
• Cable Trays
Components of KATS System

1. Clean agent Cylinder with


Valve (CE marked)
2. Gas ( UL and FM approved)
3. Thermo sensitive tube (UL
marked)
4. Pressure switch (CE marked)
5. End of adaptor
6. T connection
7. End of plug
8. MCU with hooter

Note: For the EU systems and components – there is no specific certificate. The systems will be supplied with a CofC and DofC
as they are self-certified under the PED – meaning no certificate required.
Tubing Characteristics
KEY FACTS

100o C (212OF) HIGH TECH POLYMER

FLEXIBLE RESISTANT

HOLD PRESSURE UL TESTED

LINEAR SENSOR EXTINGUISHING JET


Tubing Characteristics

TECHNICAL CHARACTERISTICS

150 PSIG (10BAR) BURST AT TYPICAL BURST @1300 PSIG


100OC (88BAR)

0.1mm – 0.2mm TOLERANCE UL & FM LONG TERM


LEAKAGE TESTS

180 DAY AGE TEST IN 100OC


1000HR UV TESTS
OVEN

30 DAY EXTREME TEMP TESTS


CHEMICALS TESTS
– Flexible
• Allows us to detect/suppress in hard to
reach areas of the equipment that may
otherwise be unprotected

– Self-contained
• No electricity required and offers
uninterrupted protection 24/7

– Detection
• Designed to activate by open flame or
ambient temperature
• Unaffected by temperature, vibration,
chemicals or other contaminates
KATS- Components

End Of Line End Of Line Tee Pressure Cross Panel


Adapter Plug Connector Switch Connector

Filling Spring Protective


Adapter Top Coil
DESIGN REQUIREMENT-Panel/Server Racks

Design Based on :

1. FM-200: NFPA 2001:2015

Basic Requirement :
1. Length
2. Width
3. Height
4. Photo Graph or Panel GAD
Design Concentration as per NFPA 2001:2015
A.5.4.2.2.B
SAMPLE DESIGN CALCULATION FOR REFERENCE (PG-1)

Design Calculation Sheet Fk-5-1-12


•Electrical Panel-1
Length = 0.7 Mtr
Height = 0.7 Mtr
Width = 2.2 Mtr

•Design Concentration = 4.5 % [As per NFPA2001:2015


Table A 5.4.2.2(b)]
=4.5* Safety Factor
=4.5*1.35
=6.07 %
SAMPLE DESIGN CALCULATION FOR REFERENCE-
(PG-2)

CONCLUSION
0.7mtr x 0.7mtr x 2.2mtr (Volume = 1.078m3)
Nearest Available Capacity= 2Kg
SAMPLE REFERENCE DRAWING FOR
TUBING CALCULATION
Inspection Schedule

Monthly
• Visually inspect all components
• Check cylinder pressure

Semi-Annually
• Check cylinder weight and pressure
• Check nozzles for obstruction

Every Six Years


• Perform external visual inspection of
cylinders
Bring your
automatic fire
detection and
suppression to
the enclosure
level

In-Cabinet Fire Protection


• Fast detection and
suppression
• The fire is localized and fire
In-Cabinet damage to other cabinet
Detection components and enclosures
is prevented
• Protect one or groups of
cabinets with one system

• Requires no power
• Installs in new or existing
cabinets
• Electrically non-conductive
Installation • Easy installation and
maintenance
• Great for remote locations
• Portable

• Scada
• Building Management
Systems
Integration • Existing Fire Alarm Systems
• Auxiliary Controls
• Fan/Damper Controls

Features and Benefits


Our Installation
Our Clients
THANK YOU