components/sub-assemblies
DESCRIPTION OF VARIOUS MODULES
SUPPLY
NAME DESCRIPTION
VOLTAGE
A-1 AC Compact Controller 110 VDC
750 VAC, 110
A-2 Disconnecting & Earthing Device
VDC
415 VAC/110
A-3 Regulated Charger (RBC)
VDC
110 VDC, 24
A-5 Pump Controller
VDC
220 VAC, 110
A-6 Insulation Control Relay AC 110V
VAC
Insulation Control Relay AC
A-7 220 VAC
240V/415V
DC/ DC Converter (110V/24V) for
A-8 Return/ Fresh Air Flap Servo 110 VDC/24 VDC
Motors, Bar Gauges & Transducers
PROTECTION DEVICES
SUPPLY
NAME DESCRIPTION
VOLTAGE
MCB (Triple Pole) 10A for Ventilation Fan
F-01 415 VAC
Motor Unit 1 (Blower Motor-1)
MCB (Triple Pole) 10A for Ventilation Fan
F-02 415 VAC
Motor Unit 2 (Blower Motor-2)
MCB (Triple Pole) 20A for Compressor
F-03 415 VAC
Motor 1.1
MCB (Double Pole) 10A for Crankcase
F-04 220 VAC
Heaters (for CP 1.1 & CP 1.2)
MCB (Triple Pole) 20A for Compressor
F-05 415 VAC
Motor 1.2
MCB (Triple Pole) 10A for Condenser Fan
F-06 415 VAC
Motor 1.1
MCB (Triple Pole) 10A for Condenser Fan
F-07 415 VAC
Motor 1.2
PROTECTION DEVICES
SUPPLY
NAME DESCRIPTION
VOLTAGE
MCB (Triple Pole) 20A for Compressor
F-09 415 VAC
Motor 2.1
MCB (Double Pole) 10A for Crankcase
F-10 220 VAC
Heaters (for CP 2.1 & CP 2.2)
MCB (Triple Pole) 20A for Compressor
F-11 415 VAC
Motor 2.2
MCB (Triple Pole) 10A for Condenser Fan
F-12 415 VAC
Motor 2.1
MCB (Triple Pole) 10A for Condenser Fan
F-13 415 VAC
Motor 2.2
MCB (Triple Pole) 16A for Heater Unit-2
F-14 415 VAC
(PPS)
F-15 MCB (Triple Pole) 16A for Exhaust Fans 415 VAC
F-16 MCB (Double Pole) 16A for Water Boiler 220 VAC
PROTECTION DEVICES
SUPPLY
NAME DESCRIPTION
VOLTAGE
F-17 MCB (Double Pole) 10A for Soup Boiler 220 VAC
F-18 MCB (Double Pole) 16A for Hot Case 220 VAC
F-40 MCB (Double Pole) 10A for Coach Light 110 VAC
PROTECTION DEVICES
SUPPLY
NAME DESCRIPTION
VOLTAGE
MCB (Double Pole) 6A for Electric Razor
F-41 110 VAC
Socket
HRC Fuse (25A) for 110V (+ve) DC
F-42 110 VAC
Supply to Panel
HRC Fuse (25A) for 110V (-ve) DC
F-43 110 VAC
Supply to Panel
HRC Fuse (100A) in R-phase of Output of
F-44 415 VAC
60 KVA Transformer
HRC Fuse (100A) in Y-phase of Output of
F-45 415 VAC
60 KVA Transformer
HRC Fuse (100A) in B-phase of Output of
F-46 415 VAC
60 KVA Transformer
HRC Fuse (80A) in Local Main Supply
F-47 415 VAC
(R-phase)
HRC Fuse (80A) in Local Main Supply
PROTECTION DEVICES
NAME DESCRIPTION SUPPLY VOLTAGE
HRC Fuse (80A) in Local Main
F-49 415 VAC
Supply (B-phase)
HRC Fuse HT (63A) in R-phase
F-50 750 VAC
for Network-1(Feeder-1)
HRC Fuse HT (63A) in Y-phase for
F-51 750 VAC
Network-1(Feeder-1)
HRC Fuse HT (63A) in B-phase
F-52 750 VAC
for Network-1(Feeder-1)
HRC Fuse HT (63A) in R-phase
F-53 750 VAC
for Network-2(Feeder-2)
HRC Fuse HT (63A) in Y-phase for
F-54 750 VAC
Network-2(Feeder-2)
HRC Fuse (80A) in Local Main
F-49 415 VAC
Supply (B-phase)
HRC Fuse HT (63A) in R-phase
PROTECTION DEVICES
SUPPLY
NAME DESCRIPTION
VOLTAGE
HRC Fuse (80A) in Local Main Supply
F-49 415 VAC
(B-phase)
HRC Fuse HT (63A) in R-phase for
F-50 750 VAC
Network-1(Feeder-1)
HRC Fuse HT (63A) in Y-phase for
F-51 750 VAC
Network-1(Feeder-1)
HRC Fuse HT (63A) in B-phase for
F-52 750 VAC
Network-1(Feeder-1)
HRC Fuse HT (63A) in R-phase for
F-53 750 VAC
Network-2(Feeder-2)
HRC Fuse HT (63A) in Y-phase for
F-54 750 VAC
Network-2(Feeder-2)
HRC Fuse HT (63A) in B-phase for
F-55 750 VAC
Network-2(Feeder-2)
Glass Fuse (4A) UIC Remote Control
PROTECTION DEVICES
Name Description Supply voltage
F-57 Glass Fuse (2A) UIC Remote Control (-ve) 24 VDC
Glass Fuse (2A) in Phase for AC 110V
F-58 110 VAC
Insulation Control Relay (A-6)
Glass Fuse (2A) in Neutral for AC 110V
F-59 110 VAC
Insulation Control Relay (A-6)
Glass Fuse (4A) in for AC 110V Insulation
F-60 Control Relay (A-6) & AC 240V /415V 220 VAC
Insulation Control Relay (A-7)
Control Relay (A-6) & AC 240V/415V
F-61 Insulation Control Relay (A-7) Glass Fuse (2A) 220 VAC
in Neutral for AC 110V Insulation
Control Relay (A-6) & AC 240V/415V
F-62 220 VAC
Insulation Control Relay (A-7)
Glass Fuse (6.3A) in +ve 110V DC for Anti
F-63 110 VDC
Skid Device
F-64 Glass Fuse (6.3A) in +ve 110V DC for Brake 110 VDC
PROTECTION DEVICES
SUPPLY
NAME DESCRIPTION
VOLTAGE
Glass Fuse (6.3A) in -ve 110V DC for Anti
F-65 110 VDC
Skid Device
Glass Fuse (6.3A) in -ve 110V DC for
F-66 110 VDC
Brake
F-67 Glass Fuse (1A) in Control Supply of K-41 220 VAC
K-29 Contactor for Exhaust Fan Motors 110 VDC, 415 VAC
K-31 Contactor for Condenser Fan Motor 1.1 110 VDC, 415 VAC
CONTACTORS & RELAYS
SUPPLY
NAME DESCRIPTION
VOLTAGE
K-32 Contactor for Condenser Fan Motor 1.2 110 VDC, 415 VAC
K-33 Contactor for Compressor Motor 1.1 110 VDC, 415 VAC
K-34 Contactor for Compressor Motor 1.2 110 VDC, 415 VAC
K-35 Contactor for Heater Unit 1 (NPPS) 110 VDC, 415 VAC
K-36 Contactor for Condenser Fan Motor 2.1 110 VDC, 415 VAC
K-37 Contactor for Condenser Fan Motor 2.2 110 VDC, 415 VAC
K-38 Contactor for Compressor Motor 2.1 110 VDC, 415 VAC
K-39 Contactor for Compressor Motor 2.2 110 VDC, 415 VAC
K-40 Contactor for Heater Unit 2 (PPS) 110 VDC, 415 VAC
K-41 Contactor for Local Main Supply-1 (LMS-1) 220 VAC, 415 VAC
CONTACTORS & RELAYS
SUPPLY
NAME DESCRIPTION
VOLTAGE
K-42 Contactor for Local Main Supply-2 (LMS-2) 220 VAC, 415 VAC
K-43 Main Contactor for Local Main Supply (LMS) 110 VDC, 415 VAC
Contactor in the Output of 60 KVA Transformer
K-44 220 VAC, 415 VAC
(After 100A Fuses)
Measuring & Monitoring Relay (MMR) for Local
K-45 110 VDC, 415 VAC
Main Supply (LMS)
Contactor in the Output of 60 KVA Transformer-2 (in
K-46 220 VAC, 415 VAC
Original German Power cars & Pantry cars)
Interlocking Contactor for Changeover of Coach
K-48 Light Supply from 110V AC to 110V DC & vice 110 VAC, 110 VDC
versa
K- Contactor for Regulated Battery Charger (Main
415 VAC
RBC Charger)
METERS
SUPPLY
NAME DESCRIPTION
VOLTAGE
P-1 Ampere Meter, AC (0-200 Amp) for Panel Load mV
P-2 Volt Meter, AC (0-800V) for Network-1 (RY) 750 VAC
P-3 Volt Meter, AC (0-800V) for Network-1 (YB) 750 VAC
DIGITAL OUTPUT
O 1 Controller OK Fault O 11
2 O1 O 11 5
3 O2 O 12 4
Recirculation Out Side
O2 O 12 O 15
4 O3 Air Air 3
5 O4 O 14 2
Ventilation Ventilation
O3 O 13
6 O5 Fan 1 Fan 2 1
X 302 Not Active in Exhaust X 502
O4 O 14
1 OC System Fan OC 6
DIGITAL OUTPUT
2 O6 O 16 5
Bypass Bypass
O5 O 15
3 O7 Cooling 1/1 Cooling 2/1 4
O 19
4 O8 O 18 3
Condenser Condenser
O6 O 16
5 O9 Fan 1/1 Fan 2/1 2
6 O 10 Condenser Condenser O 20 1
O7 O 17
X 701 Fan 1/2 Fan 2/2 X 702
1 RES Temp. -
Temp. Cond.
NETWORK
Cond.
I3 Motor 1.2 I 13
2 CH Motor 2.2
OK
OK +
3 CL Vent Motor 1 Vent Motor -
I4 I 14
4 0V Fault 2 Fault X 403 X 402
X 102 Temp. E.I. 10
Temp. E.I.
I5 Heater 2 I 15
1 RES Heater 1 OK
OK 9
NETWORK
2 CH Low Low 8
I6 Pressure 1.1 Pressure I 16
3 CL OK 2.1 OK 7
4 0V Low Low 6
I7 Pressure 1.2 Pressure I 17
X 103 OK 2.2 OK 5
RS 232 C Control Control 4
I8 I 18
X 104 Pressure 1 Pressure 2 3
High High 2
ANA L
NETWORK
I3 Motor 1.2 Cond. I 13
2 CH OK Motor 2.2
OK +
3 CL Vent Motor 1 Vent Motor -
I4 Fault 2 Fault I 14
4 0V X 403 X 402
X 102 Temp. E.I. Temp. E.I. 10
I5 Heater 1 OK Heater 2 I 15
1 RES OK 9
NETWORK
2 CH Low Low 8
I6 Pressure 1.1 Pressure I 16
3 CL OK 2.1 OK 7
4 0V Low Low 6
I7 Pressure 1.2 Pressure I 17
X 103 OK 2.2 OK 5
RS 232 C Control Control 4
I8 Pressure 1 Pressure 2 I 18
X 104 3
High High 2
ANA LOG OUT