Description of various

components/sub-assemblies
DESCRIPTION OF VARIOUS MODULES
SUPPLY
NAME DESCRIPTION
VOLTAGE
A-1 AC Compact Controller 110 VDC
750 VAC, 110
A-2 Disconnecting & Earthing Device
VDC
415 VAC/110
A-3 Regulated Charger (RBC)
VDC
110 VDC, 24
A-5 Pump Controller
VDC
220 VAC, 110
A-6 Insulation Control Relay AC 110V
VAC
Insulation Control Relay AC
A-7 220 VAC
240V/415V
DC/ DC Converter (110V/24V) for
A-8 Return/ Fresh Air Flap Servo 110 VDC/24 VDC
Motors, Bar Gauges & Transducers
PROTECTION DEVICES
SUPPLY
NAME DESCRIPTION
VOLTAGE
MCB (Triple Pole) 10A for Ventilation Fan
F-01 415 VAC
Motor Unit 1 (Blower Motor-1)
MCB (Triple Pole) 10A for Ventilation Fan
F-02 415 VAC
Motor Unit 2 (Blower Motor-2)
MCB (Triple Pole) 20A for Compressor
F-03 415 VAC
Motor 1.1
MCB (Double Pole) 10A for Crankcase
F-04 220 VAC
Heaters (for CP 1.1 & CP 1.2)
MCB (Triple Pole) 20A for Compressor
F-05 415 VAC
Motor 1.2
MCB (Triple Pole) 10A for Condenser Fan
F-06 415 VAC
Motor 1.1
MCB (Triple Pole) 10A for Condenser Fan
F-07 415 VAC
Motor 1.2
PROTECTION DEVICES
SUPPLY
NAME DESCRIPTION
VOLTAGE
MCB (Triple Pole) 20A for Compressor
F-09 415 VAC
Motor 2.1
MCB (Double Pole) 10A for Crankcase
F-10 220 VAC
Heaters (for CP 2.1 & CP 2.2)
MCB (Triple Pole) 20A for Compressor
F-11 415 VAC
Motor 2.2
MCB (Triple Pole) 10A for Condenser Fan
F-12 415 VAC
Motor 2.1
MCB (Triple Pole) 10A for Condenser Fan
F-13 415 VAC
Motor 2.2
MCB (Triple Pole) 16A for Heater Unit-2
F-14 415 VAC
(PPS)
F-15 MCB (Triple Pole) 16A for Exhaust Fans 415 VAC

F-16 MCB (Double Pole) 16A for Water Boiler 220 VAC
PROTECTION DEVICES
SUPPLY
NAME DESCRIPTION
VOLTAGE
F-17 MCB (Double Pole) 10A for Soup Boiler 220 VAC

F-18 MCB (Double Pole) 16A for Hot Case 220 VAC

F-19 MCB (Double Pole) 6A for Bottle Cooler 220 VAC


MCB (Double Pole) 6A for Refrigerator
F-20 220 VAC
(Deep Freezer)
MPCB (Motor Protection Circuit Breaker) (1
A-21 415 VAC
to 1.6A) for Water Pump-1
MPCB (Motor Protection Circuit Breaker) (1
A-22 to 1.6A) for Water Pump-2 (Overload Relay 415 VAC
for Water Pump-2)
F-24 MCB (Double Pole) 10A for Light Control 110 VDC
PROTECTION DEVICES
SUPPLY
NAME DESCRIPTION
VOLTAGE
MCB (Double Pole) 10A for Emergency
F-25 110 VDC
Lights
MCB (Double Pole) 10A for Emergency
F-26 110 VDC
Lights
MCB (Double Pole) 16A for Reading
F-27 110 VDC
Lights
MCB (Double Pole) 16A for Reading
F-28 110 VDC
Lights
MCB (Double Pole) 16A for DC/DC
F-29 110 VDC
Converter
MCB (Double Pole) 6A for Minimal
F-30 110 VDC
Voltage Relay
MCB (Double Pole) 6A for Telephone
F-31 110 VDC
(First Class only)
MCB (Double Pole) 6A for Diagnosis
PROTECTION DEVICES
SUPPLY
NAME DESCRIPTION
VOLTAGE
MCB (Double Pole) 10A for Power
F-33 110 VDC
Supply
F-34 MCB (Double Pole) 10A for Night Lights 110 VDC
MCB (Double Pole) 6A for AC Compact
F-35 110 VDC
Controller
24 VDC, 110
F-36 MCB (Double Pole) 6A for Pump Control
VDC
MCB (Double Pole) 10A for Sanitary
F-37 24 VDC
Control
MCB (Double Pole) 10A for Loud
F-38 24 VDC
Speaker
F-39 MCB (Double Pole) 10A for Coach Light 110 VAC

F-40 MCB (Double Pole) 10A for Coach Light 110 VAC
PROTECTION DEVICES
SUPPLY
NAME DESCRIPTION
VOLTAGE
MCB (Double Pole) 6A for Electric Razor
F-41 110 VAC
Socket
HRC Fuse (25A) for 110V (+ve) DC
F-42 110 VAC
Supply to Panel
HRC Fuse (25A) for 110V (-ve) DC
F-43 110 VAC
Supply to Panel
HRC Fuse (100A) in R-phase of Output of
F-44 415 VAC
60 KVA Transformer
HRC Fuse (100A) in Y-phase of Output of
F-45 415 VAC
60 KVA Transformer
HRC Fuse (100A) in B-phase of Output of
F-46 415 VAC
60 KVA Transformer
HRC Fuse (80A) in Local Main Supply
F-47 415 VAC
(R-phase)
HRC Fuse (80A) in Local Main Supply
PROTECTION DEVICES
NAME DESCRIPTION SUPPLY VOLTAGE
HRC Fuse (80A) in Local Main
F-49 415 VAC
Supply (B-phase)
HRC Fuse HT (63A) in R-phase
F-50 750 VAC
for Network-1(Feeder-1)
HRC Fuse HT (63A) in Y-phase for
F-51 750 VAC
Network-1(Feeder-1)
HRC Fuse HT (63A) in B-phase
F-52 750 VAC
for Network-1(Feeder-1)
HRC Fuse HT (63A) in R-phase
F-53 750 VAC
for Network-2(Feeder-2)
HRC Fuse HT (63A) in Y-phase for
F-54 750 VAC
Network-2(Feeder-2)
HRC Fuse (80A) in Local Main
F-49 415 VAC
Supply (B-phase)
HRC Fuse HT (63A) in R-phase
PROTECTION DEVICES
SUPPLY
NAME DESCRIPTION
VOLTAGE
HRC Fuse (80A) in Local Main Supply
F-49 415 VAC
(B-phase)
HRC Fuse HT (63A) in R-phase for
F-50 750 VAC
Network-1(Feeder-1)
HRC Fuse HT (63A) in Y-phase for
F-51 750 VAC
Network-1(Feeder-1)
HRC Fuse HT (63A) in B-phase for
F-52 750 VAC
Network-1(Feeder-1)
HRC Fuse HT (63A) in R-phase for
F-53 750 VAC
Network-2(Feeder-2)
HRC Fuse HT (63A) in Y-phase for
F-54 750 VAC
Network-2(Feeder-2)
HRC Fuse HT (63A) in B-phase for
F-55 750 VAC
Network-2(Feeder-2)
Glass Fuse (4A) UIC Remote Control
PROTECTION DEVICES
Name Description Supply voltage
F-57 Glass Fuse (2A) UIC Remote Control (-ve) 24 VDC
Glass Fuse (2A) in Phase for AC 110V
F-58 110 VAC
Insulation Control Relay (A-6)
Glass Fuse (2A) in Neutral for AC 110V
F-59 110 VAC
Insulation Control Relay (A-6)
Glass Fuse (4A) in for AC 110V Insulation
F-60 Control Relay (A-6) & AC 240V /415V 220 VAC
Insulation Control Relay (A-7)
Control Relay (A-6) & AC 240V/415V
F-61 Insulation Control Relay (A-7) Glass Fuse (2A) 220 VAC
in Neutral for AC 110V Insulation
Control Relay (A-6) & AC 240V/415V
F-62 220 VAC
Insulation Control Relay (A-7)
Glass Fuse (6.3A) in +ve 110V DC for Anti
F-63 110 VDC
Skid Device
F-64 Glass Fuse (6.3A) in +ve 110V DC for Brake 110 VDC
PROTECTION DEVICES
SUPPLY
NAME DESCRIPTION
VOLTAGE
Glass Fuse (6.3A) in -ve 110V DC for Anti
F-65 110 VDC
Skid Device
Glass Fuse (6.3A) in -ve 110V DC for
F-66 110 VDC
Brake
F-67 Glass Fuse (1A) in Control Supply of K-41 220 VAC

F-68 Glass Fuse (1A) in Control Supply of K-42 220 VAC

Glass Fuse (1A) in R-phase of K-45 (MMR


F-69 415 VAC
for LMS)
Glass Fuse (1A) in Y-phase of K-45 (MMR
F-70 415 VAC
for LMS)
Glass Fuse (1A) in B-phase of K-45 (MMR
F-71 415 VAC
for LMS)
F-72 Glass Fuse (1A) in Control Supply of K-44 220 VAC
PROTECTION DEVICES
F-73 Glass Fuse (1A) in Control Supply of K-23 220 VAC
Glass Fuse (10A) in Input Phase of Lighting
F-74 220 VAC
X’mer
Glass Fuse (10A) in Input Neutral of Lighting
F-75 220 VAC
X’mer
HRC Fuse (100A) in R-phase of Output of 60
F-76 KVA Transformer No. 2 (in Pantry car & 415 VAC
German Power car)
HRC Fuse (100A) in Y-phase of Output of 60
F-77 KVA Transformer No. 2 (in Pantry car & 415 VAC
German Power car)
HRC Fuse (100A) in B-phase of Output of 60
F-78 KVA Transformer No. 2 (in Pantry car & 415 VAC
German Power car)
HRC Fuse (63A) in R-phase for Radiator
F-79 415 VAC
Motor, Roof Extractor-1 & 2
HRC Fuse (63A) in Y-phase for Radiator
F-80 415 VAC
Motor, Roof Extractor-1 & 2
PROTECTION DEVICES
SUPPLY
NAME DESCRIPTION
VOLTAGE
HRC Fuse (63A) in B-phase for Radiator Motor, Roof
F-81 415 VAC
Extractor-1 & 2
HRC Fuse (63A) in R-phase for Radiator Motor, Roof
F-82 415 VAC
Extractor-3 & 4
HRC Fuse (63A) in Y-phase for Radiator Motor, Roof
F-83 415 VAC
Extractor-3 & 4
HRC Fuse (63A) in B-phase for Radiator Motor, Roof
F-84 415 VAC
Extractor-3 & 4
Motor Protection Circuit Breaker (MPCB) (0.1 to 2.5A)
F-85 415 VAC
for Exhaust Fan-I
Motor Protection Circuit Breaker (MPCB) (0.1 to 2.5A)
F-86 415 VAC
for Exhaust Fan-II
Motor Protection Circuit Breaker (MPCB) (0.25 to
F-87 415 VAC
4.0A) for Exhaust Fan-III
HRC Fuse (1A) in R-phase of 750V Volt Meter
F-90 750 VAC
Network-1 (Feeder-1)
PROTECTION DEVICES
SUPPLY
NAME DESCRIPTION
VOLTAGE
HRC Fuse (1A) in Y-phase of 750V Volt Meter
F-91 750 VAC
Network-1 (Feeder-1)
HRC Fuse (1A) in B-phase of 750V Volt Meter
F-93 750 VAC
Network-1 (Feeder-1)
HRC Fuse (1A) in R-phase of 750V Volt Meter
F-94 750 VAC
Network-2 (Feeder-2)
HRC Fuse (1A) in Y-phase of 750V Volt Meter
F-95 750 VAC
Network-2 (Feeder-2)
HRC Fuse (1A) in B-phase of 750V Volt Meter
F-96 750 VAC
Network-2 (Feeder-2)
HRC Fuse (1A) in Control Supply of K-01 Net-1
F-97 750 VAC
Contactor (in Rev.-D only)
HRC Fuse (1A) in Control Supply of K-01 Net-2
F-98 750 VAC
Contactor (in Rev.-D only)
HRC Fuse (1A) in Y-phase of 750V Volt Meter
F-91 750 VAC
Network-1 (Feeder-1)
PROTECTION DEVICES
SUPPLY
NAME DESCRIPTION
VOLTAGE
Glass Fuse (2A) in Phase of Insulation Control Relay
F-100 220 VAC
AC 415/240V for Transformer-1 (in Power Cars only)
Glass Fuse (2A) in Phase of Insulation Control Relay
F-101 220 VAC
AC 415/240V for Transformer-1 (in Power Cars only)
Glass Fuse (2A) in Phase of Insulation Control Relay
F-102 220 VAC
AC 415/240V for Transformer-2 (in Power Cars only)
Glass Fuse (2A) in Phase of Insulation Control Relay
F-103 220 VAC
AC 415/240V for Transformer-2 (in Power Cars only)
INDICATIONS
SUPPLY
NAME DESCRIPTION
VOLTAGE
H-1 Indication Operation Supply Network-1 110 VDC
H-2 Indication Operation Supply Network-2 110 VDC
H-3 Indication Operation Charger Float 110 VDC

H-4 Indication Operation Local Main Supply-1 110 VDC

H-5 Indication Operation Local Main Supply-2 110 VDC

H-6 Indication Operation Charger Boost 110 VDC

H-7 Indication Anti Skid Device Defect 110 VDC


H-8 Indication Insulation Failure 110V 110 VDC
H-9 Indication Insulation Failure 415V 110 VDC
H-10 Indication Operation 415V OK 110 VDC
CONTACTORS & RELAYS
SUPPLY
NAME DESCRIPTION
VOLTAGE
K-01 Main Feeder Contactor Network-1 (Feeder-1) 110 VDC, 750 VAC
K-02 Main Feeder Contactor Network-2 (Feeder-2) 110 VDC, 750 VAC
Measuring & Monitoring Relay (MMR) for Network-
K-03 24 VDC, 110 VDC,
1(Feeder-1) 750 VAC
Measuring & Monitoring Relay (MMR) for Network-
K-04 24 VDC, 110 VDC,
2(Feeder-2) 750 VAC
K-05 Timer for Anti Skid Device 110 VDC
K-06 Contactor for Electro Pneumatic Brake Application 24 VDC, 110 VDC
K-07 Contactor for Electro Pneumatic Brake Release 24 VDC, 110 VDC
Contactor for Level 1 of Minimal Voltage Relay
K-08 (MVR) (96V+120 Minutes for Emergency Light 110 VDC
OFF)
Contactor for Level 2 of Minimal Voltage
K-09 Relay(MVR) (104V+30 Minutes for DC/DC 110 VDC
Converters OFF)
Contactor for Level 3 of Minimal Voltage Relay
K-10 110 VDC, 220 VAC
(MVR) (106V for Reading Light OFF)
CONTACTORS & RELAYS
SUPPLY
NAME DESCRIPTION
VOLTAGE
K-11 Contactor for Main Light Passenger Room 110 VDC, 110 VAC
K-12 Contactor for Reading Light 110 VDC
K-13 Contactor for Night Light 110 VDC
Contactor for Main Light Entrance Area & Sanitory
K-14 110 VDC, 110 VAC
Rooms
K-15 Contactor for Emergency Light 110 VDC
K-16 Contactor for Emergency Light 110 VDC
K-17 Timer for Light ON/OFF (15-300 Min) 110 VDC
Timer for External Power Supply/ Local Main Supply
K-18 110 VDC
(L.M.S.) (for blinking of outdoor lamps)

K-19 Relay for UIC-Light-Remote Control ON 24 VDC, 110 VDC

K-20 Relay for UIC-Light-Remote Control OFF 24 VDC, 110 VDC


CONTACTORS & RELAYS
SUPPLY
NAME DESCRIPTION
VOLTAGE
K-21 Contactor for Fresh Air Flap Motor 24 VDC
K-22 Contactor for Return Air Flap Motor 24 VDC
K-23 Contactor for 415V OK 110 VDC, 220 VAC
24 VDC/110 VDC,
K-24 Contactor for Water Pump No. 1
415 VAC
24 VDC/110 VDC,
K-25 Contactor for Water Pump No. 2
415 VAC
Contactor for Ventilation Fan Motor Unit-1(Blower-
K-26 110 VDC, 415 VAC
1/NPPS)
K-27 Contactor for Controller OK 110 VDC
Contactor for Ventilation Fan Motor Unit-2 (Blower-
K-28 110 VDC, 415 VAC
2/PPS)

K-29 Contactor for Exhaust Fan Motors 110 VDC, 415 VAC

K-31 Contactor for Condenser Fan Motor 1.1 110 VDC, 415 VAC
CONTACTORS & RELAYS
SUPPLY
NAME DESCRIPTION
VOLTAGE
K-32 Contactor for Condenser Fan Motor 1.2 110 VDC, 415 VAC
K-33 Contactor for Compressor Motor 1.1 110 VDC, 415 VAC
K-34 Contactor for Compressor Motor 1.2 110 VDC, 415 VAC

K-35 Contactor for Heater Unit 1 (NPPS) 110 VDC, 415 VAC

K-36 Contactor for Condenser Fan Motor 2.1 110 VDC, 415 VAC

K-37 Contactor for Condenser Fan Motor 2.2 110 VDC, 415 VAC
K-38 Contactor for Compressor Motor 2.1 110 VDC, 415 VAC

K-39 Contactor for Compressor Motor 2.2 110 VDC, 415 VAC

K-40 Contactor for Heater Unit 2 (PPS) 110 VDC, 415 VAC

K-41 Contactor for Local Main Supply-1 (LMS-1) 220 VAC, 415 VAC
CONTACTORS & RELAYS
SUPPLY
NAME DESCRIPTION
VOLTAGE
K-42 Contactor for Local Main Supply-2 (LMS-2) 220 VAC, 415 VAC
K-43 Main Contactor for Local Main Supply (LMS) 110 VDC, 415 VAC
Contactor in the Output of 60 KVA Transformer
K-44 220 VAC, 415 VAC
(After 100A Fuses)
Measuring & Monitoring Relay (MMR) for Local
K-45 110 VDC, 415 VAC
Main Supply (LMS)
Contactor in the Output of 60 KVA Transformer-2 (in
K-46 220 VAC, 415 VAC
Original German Power cars & Pantry cars)
Interlocking Contactor for Changeover of Coach
K-48 Light Supply from 110V AC to 110V DC & vice 110 VAC, 110 VDC
versa
K- Contactor for Regulated Battery Charger (Main
415 VAC
RBC Charger)
METERS
SUPPLY
NAME DESCRIPTION
VOLTAGE
P-1 Ampere Meter, AC (0-200 Amp) for Panel Load mV
P-2 Volt Meter, AC (0-800V) for Network-1 (RY) 750 VAC
P-3 Volt Meter, AC (0-800V) for Network-1 (YB) 750 VAC

P-4 Volt Meter, AC (0-800V) for Network-1 (BR) 750 VAC

P-5 Volt Meter, AC (0-800V) for Network-2 (RY) 750 VAC

P-6 Volt Meter, AC (0-800V) for Network-2 (YB) 750 VAC


P-7 Volt Meter, AC (0-800V) for Network-2 (BR) 750 VAC
Ampere Meter, DC (+ve 100-0-100 -ve) for Charge-
P-8 mV
Discharge Battery Net
Ampere Meter, DC (0-40Amp) for Consumer Current
P-9 mV
Net
P-10 Volt Meter, DC (0-150V) for Battery Net 110 VDC
SWITCHES
SUPPLY
NAME DESCRIPTION
VOLTAGE
Switch, Selector Power Supply ON/OFF 110 VAC, 110 VDC/
S-01
(Rev.-D) 415 VAC, 750 VAC
Switch, Selector Net-1, Net-2 & LMS 110 VDC/
S-02
(Rev.-D) 415 VAC, 750 VAC
Switch, Push Button for Insulation Test Battery Net
S-03 110 VDC
+ve
Switch, Push Button for Insulation Test Battery Net –
S-04 110 VDC
ve
S-05 Switch, Push Button for Test Indication Lamps 110 VDC

S-06 Switch, Push Button for Train Light ON 24 VDC


S-07 Switch, Push Button for Train Light OFF 24 VDC
S-08 Switch, Push Button for Lighting ON 24 VDC

S-09 Switch, Push Button for Night Lighting ON 110 VDC

S-10 Switch, Push Button for Lighting OFF 110 VDC


CONVERTERS
SUPPLY
NAME DESCRIPTION
VOLTAGE
U-1 Anti Skid Device 110 VDC
DC/DC Converter (110V/24V) for Water Pump
U-2.1 110 VDC, 24 VDC
Control & Sanitory Control
DC/DC Converter (110V/24V) for Loud Speaker
U-2.2 110 VDC, 24 VDC
System MMRs & UIC Remote Control
U-2.3 Minimal Voltage Relay (MVR) 110 VDC

U-3 Amplifier Loud Speaker system 24 VDC

U-4 Air Conditioning Control Switch Panel 24 VDC, 110 VDC


THREE PHASE POWER TERMINAL FOR AC PLANT
Terminal no. Description Terminal no. Description
231 256
232 Ventilation-1 257 CD fan 1.2
233 258
234 Earth 259
235 260 Compressor 2.1
236 Ventilation-2 261
237 262 Earth
238 Earth 263
239 264 Compressor 2.2
240 Compressor 1.1 265
241 266 Earth
242 Earth 267
243 268 Heater-2
Compressor 1.2
244 269
THREE PHASE POWER TERMINAL FOR AC PLANT
Fuse No. Rating (A) Description (Located in)
75 10 Neutral Input supply to Lighting transformer
74 10 Phase Input supply to Lighting transformer
73 1 Control supply to K-23
72 1 Control supply to K-44
71 1 Blue Phase of MMR of local Main Supply
70 1 Yellow Phase of MMR of local Main Supply
69 1 Red Phase of MMR of local Main Supply
68 1 Control supply to K-42
67 1 Control supply to K-41
66 6.3 -ve 110 VDC supply for Brake
65 6.3 -ve 110 VDC supply for Anti Skid device
64 6.3 +ve 110 VDC supply for Brake
63 6.3 +ve 110 VDC supply for Anti Skid device
Neutral of AC 110 V Insulation Control relay (A-6) & AC
62 2
240/415 V Insulation Control relay (A-7)
THREE PHASE POWER TERMINAL FOR AC PLANT
Fuse No. Rating (A) Description (Located in)
61 4
Phase of AC 110 V Insulation Control relay (A-6) & AC
60 4
240/415 V Insulation Control relay (A-7)
59 2 Neutral of AC 110 V Insulation Control relay (A-6)
58 2 Phase of AC 110 V Insulation Control relay (A-6)
57 2 -ve of 24 V UIC remote control
56 4 +ve of 24 V UIC remote control
LED layout on microprocessor controller
X 301 X 501
1 OC OC 6

DIGITAL OUTPUT
O 1 Controller OK Fault O 11
2 O1 O 11 5
3 O2 O 12 4
Recirculation Out Side
O2 O 12 O 15
4 O3 Air Air 3
5 O4 O 14 2
Ventilation Ventilation
O3 O 13
6 O5 Fan 1 Fan 2 1
X 302 Not Active in Exhaust X 502
O4 O 14
1 OC System Fan OC 6
DIGITAL OUTPUT

2 O6 O 16 5
Bypass Bypass
O5 O 15
3 O7 Cooling 1/1 Cooling 2/1 4
O 19
4 O8 O 18 3
Condenser Condenser
O6 O 16
5 O9 Fan 1/1 Fan 2/1 2
6 O 10 Condenser Condenser O 20 1
O7 O 17
X 701 Fan 1/2 Fan 2/2 X 702
1 RES Temp. -
Temp. Cond.

NETWORK
Cond.
I3 Motor 1.2 I 13
2 CH Motor 2.2
OK
OK +
3 CL Vent Motor 1 Vent Motor -
I4 I 14
4 0V Fault 2 Fault X 403 X 402
X 102 Temp. E.I. 10
Temp. E.I.
I5 Heater 2 I 15
1 RES Heater 1 OK
OK 9
NETWORK

2 CH Low Low 8
I6 Pressure 1.1 Pressure I 16
3 CL OK 2.1 OK 7
4 0V Low Low 6
I7 Pressure 1.2 Pressure I 17
X 103 OK 2.2 OK 5
RS 232 C Control Control 4
I8 I 18
X 104 Pressure 1 Pressure 2 3
High High 2
ANA L

1 + I9 Pressure 1.1 Pressure I 19


Fault 2.1 Fault 1
1 I1 Compressor Compresso I 11
O8 O 18
2 I2 1/1 r 2/1 I 12
3 I3 Compressor Compresso I 13
O9 O 19
4 I4 1/2 r 2/2 I 14
DIGITAL INPUT
5 I5 O E.I. Heater I 15
E.I. Heater 1 O 20
6 IC 10 2
IC
7 I6 STAT 1 I 16
RUN :
8 I7 STAT 2 I 17
9 I8 I 18
10 I9 Air - Co. I 19
I1 400V OK I 11
11 I 10 'ON' I 20
12 IC X 104
Temp.
Temp. Cond. ANALOG
Cond.
I2 Motor 1.1 I 12 INP
X 101 Motor 2.1 +
OK
OK 4….20
MA
1 RES Temp. Cond. -

NETWORK
I3 Motor 1.2 Cond. I 13
2 CH OK Motor 2.2
OK +
3 CL Vent Motor 1 Vent Motor -
I4 Fault 2 Fault I 14
4 0V X 403 X 402
X 102 Temp. E.I. Temp. E.I. 10
I5 Heater 1 OK Heater 2 I 15
1 RES OK 9
NETWORK

2 CH Low Low 8
I6 Pressure 1.1 Pressure I 16
3 CL OK 2.1 OK 7
4 0V Low Low 6
I7 Pressure 1.2 Pressure I 17
X 103 OK 2.2 OK 5
RS 232 C Control Control 4
I8 Pressure 1 Pressure 2 I 18
X 104 3
High High 2
ANA LOG OUT

1 + I9 Pressure 1.1 Pressure I 19


Fault 2.1 Fault 1
X 104
High High
2 - Pressure 1.2 Pressure I 20 GND 2
Fault 2.2 Fault
OUT 1