You are on page 1of 30

Co-innovating For a Sustainable Future

Temperature Transmitters

YSA-CO
John Freddy Baron.
4/6/20

| Product Presentation for YTA |


© Yokogawa Electric Corporation
Expectativa de los usuarios

• Reliable Dual
Compartment housing
• Simple and Safe wiring
• 4 to 20 mA
Data

1990 2000
ANALOG DIGITAL
| Product Presentation for YTA |
© Yokogawa Electric Corporation
Users’ Expectation

• Reliable Dual • Reliable Dual


Compartment housing Compartment housing
• Simple and Safe wiring • Simple and safe wiring
• 4 to 20 mA • Digital Communications
• HART – Ver. 5
• FF– ITK 4.6
• Wireless
• SIL2 : 2000
Data

• Basic Diagnostics

1990 2000 2001 2015


ANALOG DIGITAL
| Product Presentation for YTA |
© Yokogawa Electric Corporation
Users’ Expectation

• Reliable Dual • Reliable Dual • Reliable Dual


Compartment housing Compartment housing Compartment housing
• Simple and Safe wiring • Simple and safe wiring • Simple and safe wiring
• 4 to 20 mA • Digital Communications • Digital Communications
• HART – Ver. 5 • HART – Ver. 7
• FF– ITK 4.6 • FF– ITK 6
• Wireless • Wireless
• SIL2 : 2000 • SIL2 : 2010
Data

• Basic Diagnostics • Basic Diagnostics


• Advanced Sensor level
diagnostics
• Diagnostics logs &
alerts
• Local Parameter
Setting
• Modular Lighting
Arrestors

1990 2000 2001 2015 2016 Beyond


ANALOG DIGITAL
| Product Presentation for YTA |
© Yokogawa Electric Corporation
Evolution of Yokogawa Temperature Transmitters

• Reliable Dual • Reliable Dual • Reliable Dual


Compartment housing Compartment housing Compartment housing
• Simple and Safe wiring • Simple and safe wiring • Simple and safe wiring
• 4 to 20 mA • Digital Communications • YTA610/710
Digital Communications
• HART – Ver. 5 • HART Next generation
– Ver. 7
YTA110/310/320 • FF– ITK 4.6 Field
• FF– ITK 6 mount
YTA510
Long selling • Wireless World first • Wireless
Field mount
• SIL2 : 2000 •
ISA100 wireless SIL2 : 2010
Data

• Basic Diagnostics • Basic Diagnostics


YTA70P
• Advanced Sensor level
YTA50/70
diagnostics
Panel mount
Head mount
• Diagnostics logs &
YT200 alerts
First generation
Field mount
• Local Parameter
Setting
• Modular Lighting
Arrestors

1990 2000 2001 2015 2016 Beyond


ANALOG DIGITAL
| Product Presentation for YTA |
© Yokogawa Electric Corporation
Documentos técnicos.

 YTA Transmitter Temperature.


 GS General Specifications GS 01C25R01-01EN
 IM User’s Manual IM 01C25R01-01E
 IM HART Communication IM 01C25R02-01E
 TI Technical Information TI 01C25R51-01E-E
 SD Drawings SD 01C25R01-01E
 CPML Customer Maintenance CMPL 01C25A03-02E
Parts List

| Document
| Product
Number|
Presentation
February
for YTA
29, 2016
| |
Copyright
© Yokogawa
© Yokogawa
Electric
Electric
Corporation
Corporation
6
Family Overview

Model YTA50 YTA70 YTA110 YTA310 YTA320


Appearance

Output 4-20mA 4-20mA 4-20mA 4-20mA or


Fieldbus
Communication None HART BRAIN BRAIN BRAIN
HART HART HART
Fieldbus
Acceptable TC:12types, TC:12types, RTD:6types, DC Voltage
sensor type RTD:2types,DC Voltage and Resistance
and Resistance
Number of input 1 1 1 2
Integral Indicator レ
SIL2 Certification レ(except Fieldbus type)

| Product Presentation for YTA |


© Yokogawa Electric Corporation
New premium product -YTA710- Premium

Development policy
Development
 Yokogawa own development product
Satisfy all requirements
 HART 7, SIL2, NAMUR, LPS display, Variety of protocols
Factory cost down
Improvement of L/T
Product reliability and quality assurance
New-YTA
 Quality comes first

New
| Product Presentation for YTA |
© Yokogawa Electric Corporation
MS Code

Model Code Description


YTA610
・・・・・・・・・・・・・・・・・ Temperature Transmitter
YTA710
Output -J ・・・・・・・・・・・・・・・ 4 to 20mA DC with HART 7 protocol
Signal -F ・・・・・・・・・・・・・・・ FOUNDATION Fieldbus protocol
- A ・・・・・・・・・・・・・ Always A  
1 ・・・・・・・・・・・ Single
Sensor input
2  ・・・・・・・・・・・ Double
A ・・・・・・・・・ Aluminum
Housing code
C  ・・・・・・・・・ Stainless
0 ・・・・・・・・ G1/2 female
Electrical Connection 2 ・・・・・・・・ 1/2 NPT female
4 ・・・・・・・・ M20 female
D ・・・・・ Digital indicator with Local Operating Switch
Integral Indicator
N ・・・・・ None
B ・・・ 304SST 2Bhorizontal pipe
D ・・・ 304SST 2Bvertical pipe
Mounting Bracket J ・・・ 316SST 2Bhorizontal pipe
K ・・・ 316SST 2Bvertical pipe
N ・・・ None

| Product Presentation for YTA |


© Yokogawa Electric Corporation
MS Code (option code)

Item Description Code

Lightning protector Exchange type arrestor A

Coating High anti-corrosion coating X2


Coating color Amplifier cover to black, jade green and silver P1,P2,P7
change Amplifier and terminal cover to red PR
Wired tag plate 316SST stainless steel wired tag plate N4
standard output range with low side failure alarm C1
Output signal
NE43 compliant output range with down-scale failure alarm C2
(for HART only)
NE43 compliant output range with up-scale failure alarm C3

Data Configuration HART Descriptor CA

Sensor matching enable sensor matching function for RTD CM1


multiple protection type of Ex d & i □U?,
Explosion proof
□=K:ATEX, S:IECEx, F:FM, C:CSA/FM(Canada)… □U2?
High accuracy ( only for 710) HAC

Enhanced ambient temperature effect ( only for 710) R1

| Product Presentation for YTA |


© Yokogawa Electric Corporation
Factory Configuration

 For HART
Factory setting Item order instruction name Default value Note
in GS
Sensor type SENSOR 1 TYPE Sensor1: Pt100 3-wire Explanation detail in
SENSOR 2 TYPE Sensor2: non-connection next slide
Calibration range and RANGE (1) 0 to 100 °C
unit RANGE (2)
Tag Number TAG NO. (blank)
Software tag SOFTWARE TAG Same as “Tag Number”
Sensor backup SENSOR BACKUP Disable
Damping time --- 2 sec Cannot specified
Sensor burnout --- High (110%) Except option C1, C2
or C3 is specified
Output in transmitter --- High (110% or more)
failure

| Product Presentation for YTA |


© Yokogawa Electric Corporation
Factory Configuration

 For FF
Factory setting order instruction name Default value Note
Item in GS
Sensor type SENSOR 1 TYPE Sensor1: Pt100 3-wire Explanation
SENSOR 2 TYPE Sensor2: non-connection detail in next
slide
Calibration range RANGE (1) Sensor1: 0 to 100 °C
RANGE (2) Sensor2: non-connection
Units of
calibration range
Output mode OUTPUT MODE(1) Direct
OUTPUT MODE(2)
Output scale SCALE-1 Sensor1: 0 to 100%
SCALE-2 Sensor2: non-connection
Output scale unit
Tag Number TAG NO. (blank)
Software Tag SOFTWARE TAG TT1001
Node address NODE ADDRESS (HEXADECIMAL) 0xF3
Operation function OPERATION FUNCTIONAL CLASS BASIC
class
Sensor backup SENSOR BACKUP Disable

| Product Presentation for YTA |


© Yokogawa Electric Corporation
Key Features of YTA

High Accuracy & Long


Term Stability
HART7,
High Reliability Dual FF ITK6 with Firmware
Compartment Housing download

Custom TC Sensor
Table

Display with Local


Parameter Setting Safety IEC 61508:2010
New-YTA
as standard (SIL2)

Low copper housing NE43, 89, 107


<0.1% Copper Advanced
Diagnostics

| Product Presentation for YTA |


© Yokogawa Electric Corporation
LPS
 Local Parameter Setting
 Implement basic parameters
 Similar operation way as EJX LPS

Set switch Scroll switch

| Product Presentation for YTA |


© Yokogawa Electric Corporation
Construcción de vivienda de doble compartimento

 Circuitos electrónicos autóno


mos sellados con terminales
de cableado aislados
 Prensaestopas conectados al
compartimiento trasero
 No hay ingreso de humedad
a las tarjetas electrónicas mie
ntras se accede a la terminal.
 IP66/67, NEMA 4X

| Product Presentation for YTA |


© Yokogawa Electric Corporation
Terminal de cableado multinivel.
 Acceso directo al cableado
 Terminación multinivel

Sensor Termination Power / Output

Safe And Easy Wiring


| Product Presentation for YTA |
© Yokogawa Electric Corporation
Pararrayos (Lightning Arrestors).
 Cambio en campo.
 Fácil de instalar en la terminal de cableado

| Product Presentation for YTA |


© Yokogawa Electric Corporation
Resumen de funciones nuevas / mejoradas

  Item Feature Remark


Improve the accuracy in many sensor type Enhance
Accuracy
High Accuracy /HAC option for PT100 New
FF function Brock Shortening of execute time Enhance
Performance
Housing Low copper material Enhance
Coating option Double layer coating /X2 option Enhance
Exterior parts 316 SST as standard Enhance
Sensor types adding custom TC sensor table and Pt1000 New
LPS Local Parameter setting function New
Diagnostics adding advanced diagnostics Enhance
Alarm log Logging alarm and timestamp Enhance  
Function
Protocol HART 7, Fieldbus ITK6 New
FF Soft-Download ITK6 compliance New
FF function Brock Adding IS, SC and AR Brock New
Lightning protector Detachable type New
Certificate Safety IEC61508 ( 2010 ) Enhance
Other LCD panel Similar LCD panel as EJX Enhance

| Product Presentation for YTA |


© Yokogawa Electric Corporation
Especificaciones clave

specification YTA710 YTA610


Housing dual compartment, Low copper material
HART7 ✔
Fieldbus ITK 6.1 ✔
Profibus-PA (TBD)
Sensor input Single/Dual
SIL2 ✔ ✔ (under application)
LPS function ✔
Accuracy (Pt100) ±0.1℃ ±0.14℃
Accuracy (TC TypeK) ±0.25℃ ±0.3℃
CJC accuracy ±0.5℃
RTD Sensor matching ✔
RTD: 0.2% or 0.2℃@5 years RTD: 0.25% or 0.25℃@5 years
Stability
TC: 0.4% or 0.4℃@5 years TC: 0.5% or 0.5℃@5 years
Diagnostics Advance Basic

| Product Presentation for YTA |


© Yokogawa Electric Corporation
Descripción general de los diagnósticos del sensor

Item YTA710 YTA610


TC/mV Failure ✔ ✔
RTD/Ohm Failure ✔ ✔
Terminal block Failure ✔ ✔
NEW TC Short ✔

NEW RTD Short ✔

NEW RTD Corrosion ✔

NEW TC/mV Sensor diagnostics ✔ ✔


Sensor Drift ✔ ✔
NEW
Temperature Cycle
NEW Diagnostics ✔

| Product Presentation for YTA |


© Yokogawa Electric Corporation
Diagnostico del sensor
 Falla del sensor
• Detección de desconexión del sensor
• Alarma generada: Sensor1 / 2 Failure (AL.10 / 11)

 Falla del bloque de terminales


 Detección de desconexión del termopar CJC
 Generación de alarma por encima del valor umbral de C
JC
 Alarma generada: Terminal Sensor Fail (AL.22)

| Product Presentation for YTA |


© Yokogawa Electric Corporation
Diagnostico del sensor NEW FEATURE

 TC Short
 Adapt to NE89 additional, optional requirement 6.1
 Para detectar un cortocircuito en los brazos de un termop
ar antes de su punto de medición.
 Genera una alarma corta de sensor cuando la resistencia de líne
a del bucle de medición está por debajo del valor de umbral.
 Tipo de sensor aplicable: TC
 Ajuste de parámetros: valor de umbral para S1 y S2
 Alarma generada: Sensor1 / 2 corto (AL.12 / 13)

Line resistance
Alarm

threshold

Operating time

| Product Presentation for YTA |


© Yokogawa Electric Corporation
Diagnostico del sensor
 RTD Short NEW FEATURE
 Adapt to NE89 additional requirement 5.2.2.1.4
 Para detectar un cortocircuito en el bucle de medición de RTD a
ntes de su elemento sensor.
 Genera una alarma corta de sensor cuando la resistencia de lín
ea del bucle de medición está por debajo del valor de umbral.
 Tipo de sensor aplicable: RTD de 3 y 4 hilos
 Ajuste de parámetros: -
 Alarma generada:
Sensor1 / 2 corto (AL.12 / 13)
Line resistance
Alarm

threshold

Operating time

| Product Presentation for YTA |


© Yokogawa Electric Corporation
Diagnostico del sensor
NEW FEATURE
 RTD Corrosión
 Adaptarse a NE89 requisito adicional 5.2.2.1.2
 Mantenimiento preventivo y detección de aumento en la r
esistencia de línea del lazo de medición.
 Genera una alarma de corrosión cuando la resistencia ex
cede el umbral
 Tipo de sensor aplicable: RTD de 3 y 4 hilos
 Configuración de parámetros: valor de umbral
 Alarma generada: AL.14 / 15 threshold

Line resistance Alarm

Operating time

| Product Presentation for YTA |


© Yokogawa Electric Corporation
Diagnostico del sensor
NEW FEATURE
 TC / mV sensor de diagnóstico
 Relacionado con NE89 requisito adicional 5.2.2.2.2
 Esta función proporciona resistencia de línea de lazo de
medición para mantenimiento preventivo.
 Tipo de sensor aplicable: TC y mV
 Ajuste de parámetros: -
 Alarma generada: -
 Salida: valor de resistencia de línea
 Circuito de diagnóstico: igual que la falla del sensor

| Product Presentation for YTA |


© Yokogawa Electric Corporation
Diagnostico del sensor
 Deriva del sensor NEW FEATURE
 Cuando la diferencia entre Sensor 1 y Sensor 2 excede el u
mbral, esta función genera una alarma de deriva del sensor.
Esto indica que hay algún problema en Sensor 1 o Sensor 2.
 Tipo de sensor aplicable: RTD y TC, sensor dual
 Configuración de parámetros: umbral para la diferencia de te
mperatura entre Sensor 1 y 2
 Alarma generada: Sensor Drift (AL.25)
Alarm

Deference between
threshold

Sns1 and 2

Operating time

| Product Presentation for YTA |


© Yokogawa Electric Corporation
Diagnostico del sensor
 Diagnóstico del ciclo de temperatura NEW FEATURE
 Adáptese a NE89 adicional, requisito opcional 6.5
 Esta función es para mantenimiento preventivo e indica cuántas
veces la temperatura alterna alternativamente los límites superi
or e inferior. Cuando el número de veces excede el umbral, se g
enerará una alarma.
 Tipo de sensor aplicable: TC y RTD
 Parametrización: ciclo de temperatura número de veces, límite
de temperatura superior e inferior

Measurement temperature
EX) Cycle number of time setting to 2
 Alarma generada: AL.26 / 27
Upper limit

Lower limit

1 time 3 times ->Alarm


2 times

Operating time

| Product Presentation for YTA |


© Yokogawa Electric Corporation
Función de registro de alarma
 Hasta cuatro historiales de alarma sellados con el t
iempo almacenados en la memoria del transmisor
 Registro máximo / mínimo: el valor mínimo y máxi
mo de las variables de proceso se almacena en la
memoria del transmisor.
 Tiempo de operación: temporizador para contar el t
iempo de operación desde el primer encendido par
a el registro de alarma de sellado de tiempo.

Easy Trouble Shooting


| Product Presentation for YTA |
© Yokogawa Electric Corporation
Soluciones aptas para el propósito
High

Ultimate
YTA710
Price

Essential
YTA610

Low Cost

High
Performance / Functionality

| Product Presentation for YTA |


© Yokogawa Electric Corporation
Thank you for your attention!