CONTENTS
Suction Screen
Air Leak
High Flash-Zone Pressure
Thermal Cracking
Suction screen
During thermal cracking coke is formed and it washed
into the pump suction.
So it will block the suction screen.
Pressure survey will identify this problem
Pressure at the pump suction & above the liquid level
in the boot is calc &expressed in feet.
It should be equal to the ht of the liq level in the boot
If the pressure diff is a bit less than the ht then the
pump suction screen is plugged
So it should be cleaned.
Air Leak
If any leak in a flange on the pump suction piping then
there will be loss of NPSH
Any air sucked in it will reduce the density and it will
reduce the head of the liquid
If head is decreasing we can say that there is a leak
Air can also enter through the bad seal
Seal oil pressure will reduce the cavitation
Pour the seal oil onto the seal to check any leaks
Precautions have to be taken because this could cause a
seal oil fire
High Flash-Zone Pressure
Reduce the resid will depend upon T &P
Increase in pressure increase the resid
Vacuum tower pressure survey will troubleshoot this
problem
Before starting trays, demister, ejectors should be
clean & in good condition
Pressure calculated by portable mercury filled
manometer /vacuum pressure guage
2 pressure surveys were done
1.before start up
2.during the running of the tower
wash oil is added but will the production of
undesirable trim gas oil
in pressure around top/bottom pump around trays
will indicate flooding
High P result in air leaks, excessive production of
hydrocarbon gases etc can be observed.
Thermal Cracking
If we increase the flash zone temp then
there will decrease the
amt of resid
Thermal Cracking will rates double
for every increase in 200F-250F
Production of non
condensable gases increases
with temp
Overload the ejector system
Increases the coke on demister pad
Overcoming the high flash zone pressure by increasing the temp
is not a good idea.