Professional Documents
Culture Documents
INPUT ALLOCATION
OUTPUT ALLOCATION
Direct
Symbol Remarks Direct
Address Symbol Remarks
Address
Start_PB I0.0 Start push button
Cylinder A Q0.0 Mold Clamp
Stop_PB I0.1 Stop push button
Cylinder B Q0.1 Ejector
a0 I0.2 A- sensor
Motor CW Q0.2 Resin Injector Adv
a1 I0.3 A+ sensor
Motor CCW Q0.3 Resin Injector Ret
b0 I0.4 B- sensor
Air Cool Sol Q0.4 Air Blower
b1 I0.5 B+ sensor
Ls1 I0.6 Motor CW limit
Ls2 I0.7 Motor CCW limit
SEQUENTIAL FUNCTION CHART
Start STEP 0
Start PB
STEP 1
Cylinder A+
a1
Motor CW STEP 2
Lsw1
Motor OFF STEP 3
Cooler ON
3 sec.
Cooler OFF STEP 4
Motor CCW
Lsw2
Cylinder A- STEP 5
Motor OFF
a0
STEP 6
Cylinder B+
b1
STEP 7
Cylinder B-
b0
STEP 1
ACTUATION TABLE
Cylinder B 0 0 0 0 0 0 1 0
Motor CW 0 0 1 0 0 0 0 0
Motor CCW 0 0 0 0 1 0 0 0
Air Cool Sol 0 0 0 1 0 0 0 0